ceiling mounted duct unit - daikin comfort

20
Ceiling Mounted Duct Unit FXMQ-MVJU EDUS39-900B-F11 202103 Engineering Data 60 Hz

Upload: others

Post on 04-Oct-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ceiling Mounted Duct Unit - Daikin Comfort

Ceiling Mounted Duct UnitFXMQ-MVJU

EDUS39-900B-F11202103

Engineering Data

60 Hz

Page 2: Ceiling Mounted Duct Unit - Daikin Comfort
Page 3: Ceiling Mounted Duct Unit - Daikin Comfort

1

FXMQ-MVJU EDUS39-900B-F11

Table of Contents

1. FeaturesandBenefits ................................................................................22. Specifications .............................................................................................33. SimplifiedDimensions ................................................................................44. Dimensions .................................................................................................55. CenterofGravity ........................................................................................66. PipingDiagrams .........................................................................................77. WiringDiagrams .........................................................................................88. Electric Characteristics .............................................................................109. SafetyDeviceSetting ...............................................................................1010.CapacityTables ........................................................................................ 11

10.1CoolingCapacityatTe:43°F(6°C) ................................................. 1110.2HeatingCapacity ............................................................................. 1110.3CorrectionFactorforCoolingCapacityatTe:48°F(9°C) ............... 11

11.FanPerformances ....................................................................................1212.SoundLevels(ReferenceData) ...............................................................14

12.1Overall .............................................................................................1412.2OctaveBandLevel ..........................................................................15

13.Accessories ..............................................................................................1613.1OptionalAccessories(forUnit) .......................................................16

Page 4: Ceiling Mounted Duct Unit - Daikin Comfort

2

FXMQ-MVJU EDUS39-900B-F11

1. Features and Benefits

Concealed, Powerful, ComfortableTheHSPhigh-capacityconcealedductedunitisidealforlargeropenspacefloorplansusuallyfoundinoffices,retails,hotels,oreducationfacilities.Itperformswellacrossmultiplespacesthatcanbenefitfromthesamemodeofoperation,limitingequipmentandinstallationcost.

� Designflexibilitywithacapacityrangeupto96MBH � ImprovedductworkandfiltrationflexibilitywithESPcapabilityofupto1.1”W.G � Lowprofiledesignoflessthan19”hightoreducerequiredinstallationspace � IdealforHotels,Schools,Retail

FXMQ72-96MVJU

Page 5: Ceiling Mounted Duct Unit - Daikin Comfort

3

FXMQ-MVJU EDUS39-900B-F11

2. Specifications

Ceiling mounted duct unit

Model FXMQ72MVJU FXMQ96MVJUPowersupply 1phase,60Hz,208/230V 1phase,60Hz,208/230VH1,H3Coolingcapacity Btu/h 72,000 96,000H2,H3Heatingcapacity Btu/h 81,000 108,000Casing/Color Galvanizedsteelplate GalvanizedsteelplateDimensions:(H×W×D) in. 18-1/8×54-3/8×43-5/16 18-1/8×54-3/8×43-5/16Coil(crossfincoil)

Rows×Stages×FPI 3×26×13 3×26×13Face area ft² 7.32 7.32

Fan

Model D13/4G2DA1×2 D13/4G2DA1×2Type Siroccofan SiroccofanMotoroutput W 380×2 380×2Airflowrate(H/L) cfm 2,047/1,764 2,541/2,188Externalstaticpressure(208V) in. H2O 0.95-0.38H4 0.95-0.44H4

Drive Directdrive DirectdriveTemperaturecontrol Microprocessorthermostatforcoolingandheating MicroprocessorthermostatforcoolingandheatingAirfilter — H5 — H5H6Soundpressurelevel(referencedata)(H/L) dBA 49.0/46.0 49.0/46.0

Weight lbs 302 302

Piping connections

Liquidpipes in. f3/8(flareconnection) f3/8(flareconnection)Gaspipes in. f3/4(brazingconnection) f7/8(brazingconnection)Drainpipe in. PS1B PS1B

Safetydevices Fuse,Thermalprotectorforfanmotor Fuse,ThermalprotectorforfanmotorRefrigerantcontrol Electronicexpansionvalve ElectronicexpansionvalveConnectableoutdoorunit R410AVRV series R410AVRV series

Standardaccessories Operationmanual,Installationmanual,Sealingpads,Connectionpipes,Screws,Clamps

Operationmanual,Installationmanual,Sealingpads,Connectionpipes,Screws,Clamps

Note:H1. Nominalcoolingcapacitiesarebasedonthefollowingconditions:

Returnairtemperature:80°FDB,67°FWB Outdoortemperature:95°FDB Equivalentrefrigerantpipinglength:25ft(horizontal)

H2. Nominalheatingcapacitiesarebasedonthefollowingconditions: Returnairtemperature:70°FDB. Outdoortemperature:47°FDB,43°FWB Equivalentrefrigerantpipinglength:25ft(horizontal)

H3. Capacitiesarenet,includingadeductionforcooling(anadditionforheating)forindoorfanmotorheat.H4. Externalstaticpressureischangeabletochangeovertheconnectorsinsideelectricalbox,thispressuremeans“High

staticpressure-Standardstaticpressure”.H5. Airfilterisnotstandardaccessory,butpleasemountitintheductsystemofthesuctionside.

Selectitsdustcollectionefficiency(gravitymethod)50%ormore.H6. Anechoicchamberconversionvalue,measuredunderJISconditions.Duringactualoperation,

thesevaluesmaybehigherasaresultofinstallationconditions.

C:3D065683A

Page 6: Ceiling Mounted Duct Unit - Daikin Comfort

4

FXMQ-MVJU EDUS39-900B-F11

3. Simplified Dimensions

FXMQ72-96MVJU

DFT

5183

493

Uni

t: in

. (m

m)

Page 7: Ceiling Mounted Duct Unit - Daikin Comfort

5

FXMQ-MVJU EDUS39-900B-F11

4. Dimensions

FXMQ72-96MVJU

C :

3D06

5655

Uni

t: in

.

Page 8: Ceiling Mounted Duct Unit - Daikin Comfort

6

FXMQ-MVJU EDUS39-900B-F11

5. Center of Gravity

FXMQ72-96MVJU

4D065654

Unit: in.

Page 9: Ceiling Mounted Duct Unit - Daikin Comfort

7

FXMQ-MVJU EDUS39-900B-F11

6. Piping Diagrams

FXMQ72-96MVJU

Unit:in.Model Gas Liquid

FXMQ72MVJU f3/4 f3/8FXMQ96MVJU f7/8 f3/8

C: 4D034245R

Page 10: Ceiling Mounted Duct Unit - Daikin Comfort

8

FXMQ-MVJU EDUS39-900B-F11

7. Wiring Diagrams

FXMQ72-96MVJU

C: 3

D06

5414

D

NO

TES)

1.

: TE

RM

INAL

BLO

CK

,

:

CO

NN

ECTO

R

: SH

OR

T C

IRC

UIT

CO

NN

ECTO

R

:

TER

MIN

AL2.

: FIE

LD W

IRIN

G3.

IN C

ASE

USI

NG

CEN

TRAL

REM

OTE

CO

NTR

OLL

ER, C

ON

NEC

T IT

TO

TH

E U

NIT

IN A

CC

OR

DAN

CE

WIT

H T

HE

ATTA

CH

ED IN

STR

UC

TIO

N M

ANU

AL.

4. W

HEN

CO

NN

ECTI

NG

TH

E IN

PUT

WIR

ES F

RO

M O

UTS

IDE,

FO

RC

ED O

FF O

R O

N/O

FF C

ON

TRO

L O

PER

ATIO

N C

AN B

E SE

LEC

TED

BY

REM

OTE

CO

NTR

OLL

ER.

IN

DET

AILS

, REF

ER T

O T

HE

INST

ALLA

TIO

N M

ANU

AL A

TTAC

HED

TH

E U

NIT

.5.

SYM

BOLS

SH

OW

AS

FOLL

OW

S. (P

NK:

PIN

K W

HT:

WH

ITE

YLW

: YEL

LOW

OR

G: O

RAN

GE

BLU

: BLU

E B

LK: B

LAC

K R

ED: R

ED B

RN

: BR

OW

N)

6.

USE

CO

PPER

CO

ND

UC

TOR

S O

NLY

.7.

IN C

ASE

HIG

H E

. S. P

. OPE

RAT

ION

, CH

ANG

E TH

E SW

ITC

H (S

S) F

OR

“H”.

8. C

LASS

2 W

IRE.

Page 11: Ceiling Mounted Duct Unit - Daikin Comfort

9

FXMQ-MVJU EDUS39-900B-F11

FXMQ72-96MVJU

ELECTRICALCOMPONENTSANDWIRINGCONNECTORSFORINDOORUNITA1P PRINTEDCIRCUITBOARDC1·C2 CAPACITOR(M1F·2F)F1U FUSE( B ,5A,250V)HAP LIGHTEMITTINGDIODE(SERVICEMONITOR-GREEN)K1M MAGNETICCONTACTOR(M1F·2F)K2M MAGNETICCONTACTOR(M1F·2F)K3M MAGNETICCONTACTOR(M1F·2F)K1R-K3R MAGNETICRELAY(M1F·2F)KPR MAGNETICRELAY(M1P)M1F·M2F MOTOR(INDOORFAN)Q1M·Q2M THERMOSWITCH(M1F·2FEMBEDDED)R1T THERMISTOR(AIR)R2T·R3T THERMISTOR(COIL)SS SELECTORSWITCH(STATICPRESSURE)T1R TRANSFORMER(208V/230V25VA)X1M TERMINALBLOCK(POWER)X2M-X3M TERMINALBLOCKX4M TERMINALBLOCK(CONTROL)Y1E ELECTRONICEXPANSIONVALVECONNECTORFOROPTIONALPARTSX8A CONNECTOR(FLOATSWITCH)X18A CONNECTOR(WIRINGADAPTORFORELECTRICALAPPENDICES)

C:3D065414D

Page 12: Ceiling Mounted Duct Unit - Daikin Comfort

10

FXMQ-MVJU EDUS39-900B-F11

8. Electric Characteristics

FXMQ72-96MVJU

ModelPowersupply IFM Input(W)

SCCRHz Volts Voltagerange MCA MOP KW FLA Cooling Heating

FXMQ72MVJU60 208/230V Max.253V

Min.187V9.5 15 0.380×2 7.6 1,490 1,490 SCCRkArms,

Symmetrical@600VMAX:5FXMQ96MVJU 10.7 15 0.380×2 8.6 1,684 1,684

Symbol:MCA: Min.CircuitAmps(A)MOP: Max.OvercurrentProtectiveDevice(A)KW: FanMotorRatedOutput(kW)FLA: FullLoadAmps(A)IFM: IndoorFanMotorSCCR:Short-CircuitCurrentRating

Note:1.Voltagerange Unitsaresuitableforuseonelectricalsystemswherevoltagesuppliedtounitterminalsisnotbeloworabovelistedrangelimits.

2.Maximumallowablevoltageunbalancebetweenphaseis2%.3.MCA/MOP MCA=1.25×FLA MOP≤4×FLA (Nextlowerstandardfuseraring.Min.15A)

4.SelectwiresizebasedontheMCA.

C:4D065597

9. Safety Device Setting

Model FXMQ72MVJU FXMQ96MVJUPrintedcircuitboardfuse 250V,5A 250V,5AFanmotorthermalfuse °F – –

Fanmotorthermalprotector °F OFF:275±14(ON:189±27)

OFF:275±14(ON:189±27)

Page 13: Ceiling Mounted Duct Unit - Daikin Comfort

11

FXMQ-MVJU EDUS39-900B-F11

10. Capacity Tables10.1 Cooling Capacity at Te: 43°F (6°C)

Model

Indoorairtemp.°FWB(°CWB)(Te:43°F(6°C))61(16.1) 64(17.8) 67(19.4) 70(21.1) 72(22.2) 75(23.9)

TC SHC TC SHC TC SHC TC SHC TC SHC TC SHCMBH MBH MBH MBH MBH MBH MBH MBH MBH MBH MBH MBH

FXMQ72MVJU 56.9 50.8 64.4 53.8 72.0 56.9 73.4 56.5 74.4 55.0 75.8 52.8FXMQ96MVJU 75.8 63.7 85.9 67.4 96.0 71.1 97.9 70.5 99.2 69.1 101.0 65.8

TC: Totalcapacity:MBHSHC:Sensibleheatcapacity:MBH

Note:1.ThesecapacitytablescanbeusedwhenselectingaVRVindoorunit.TheactualcapacityoftheVRVsystemdependsonfactorssuchastheselectedmodelofoutdoorunits,outdoorairtemperatureandpipinglength.PleaseconfirmthatthecorrectedcapacityoftheVRVsystemsatisfiestherequiredheatload.

2. showsratedcondition.

10.2 Heating Capacity

Model

Indoorairtemp.°FDB(°CDB)(Tc:115°F(46°C))62(16.7) 65(18.3) 68(20.0) 70(21.1) 72(22.2) 75(23.9)

TC TC TC TC TC TCMBH MBH MBH MBH MBH MBH

FXMQ72MVJU 94.5 88.5 84.0 81.0 78.0 73.5FXMQ96MVJU 126 118 112 108 104 98.0

TC:Totalcapacity:MBH

Note:1.ThesecapacitytablescanbeusedwhenselectingaVRVindoorunit.TheactualcapacityoftheVRVsystemdependsonfactorssuchastheselectedmodelofoutdoorunits,outdoorairtemperatureandpipinglength.PleaseconfirmthatthecorrectedcapacityoftheVRVsystemsatisfiestherequiredheatload.

2. showsratedcondition.

10.3 Correction Factor for Cooling Capacity at Te: 48°F (9°C)

Refertothecorrectionfactortablebelowwhenamini-splitindoorunit isconnectedtoaVRVHeatPumpsystemusingaBranchPortbox.

ModelIndoorairtemp.°FWB(°CWB)(Te:48°F(9°C))

57(13.9) 61(16.1) 64(17.8) 67(19.4) 70(21.1) 72(22.2) 75(23.9)TC SHF TC SHF TC SHF TC SHF TC SHF TC SHF TC SHF

FXMQ72MVJU 0.68 1.13 0.70 1.16 0.76 1.11 0.80 1.08 0.82 1.06 0.84 1.06 0.86 1.05FXMQ96MVJU 0.68 1.13 0.72 1.15 0.78 1.10 0.81 1.08 0.83 1.06 0.84 1.05 0.86 1.06

TC: TotalcapacitySHF:Sensibleheatfactor

CA14A307C

Page 14: Ceiling Mounted Duct Unit - Daikin Comfort

12

FXMQ-MVJU EDUS39-900B-F11

11. Fan Performances

FXMQ72MVJU

Note:1.Theremotecontrollercanbeusedtoswitchbetween“high”and“low”.2.Theairflowissetto“standard”beforeleavingthefactory. Itispossibletoswitchbetween“standardESP”and“highESP”bychangingtheswitchintheindoorunitelectricalbox.

3D065628B

Page 15: Ceiling Mounted Duct Unit - Daikin Comfort

13

FXMQ-MVJU EDUS39-900B-F11

FXMQ96MVJU

Note:1.Theremotecontrollercanbeusedtoswitchbetween“high”and“low”.2.Theairflowissetto“standard”beforeleavingthefactory. Itispossibletoswitchbetween“standardESP”and“highESP”bychangingtheswitchintheindoorunitelectricalbox.

3D065629B

Page 16: Ceiling Mounted Duct Unit - Daikin Comfort

14

FXMQ-MVJU EDUS39-900B-F11

12. Sound Levels (Reference Data)12.1 Overall

n Location of microphone

6.6 ft

4.9

ft

3.3 ft

DISCHARGE SUCTION

MICROPHONE

DUCT DUCT

Note:1.Operationnoisedifferswithoperationandambientconditions.

dBA

Model208/230V,60Hz

H LFXMQ72MVJU 49.0 46.0FXMQ96MVJU 49.0 46.0

Page 17: Ceiling Mounted Duct Unit - Daikin Comfort

15

FXMQ-MVJU EDUS39-900B-F11

12.2 Octave Band Level

208/230V,60Hz

FXMQ72MVJU FXMQ96MVJU

C: 4D068573 C: 4D068754

Page 18: Ceiling Mounted Duct Unit - Daikin Comfort

16

FXMQ-MVJU EDUS39-900B-F11

13. Accessories13.1 Optional Accessories (for Unit)

Option FXMQ72MVJU FXMQ96MVJU

Highefficiencyfilter65% KAF372M28090% KAF373M280

Filterchamber KDJ3705L280Longlifereplacementfilter KAF371M280

C:3D065676

Page 19: Ceiling Mounted Duct Unit - Daikin Comfort
Page 20: Ceiling Mounted Duct Unit - Daikin Comfort

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.

Cautions on product corrosion

Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.

Read the user’s manual carefully before using this product. The user’s manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.

If you have any inquiries, please contact your local importer, distributor and/or retailer.

©All rights reserved 03/21 FS

●Specifications, designs and other content appearing in this brochure are current as of March 2021 but subject to change without notice.