netally linkrunner™ g2 manual - test equipment depot · 2019. 11. 19. · userguide may29,2019....

103
LINKRUNNER G2 Smart Network Tester User Guide May 29, 2019

Upload: others

Post on 25-Mar-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

LINKRUNNER™ G2Smart Network Tester

User Guide

May 29, 2019

Page 2: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Legal NotificationUse of this product is subject to the End User License Agree-ment or which accompanies the product at the time of shipment or, if applicable, the legal agreement executed by and between NetAlly, and the purchaser of this product.Open-Source Software Acknowledgment: This product may incorporate open-source components. NetAlly will make avail-able source code components of this product, if any, NetAlly reserves the right, at its sole discretion, to make changes at any time in its technical information, spe-cifications, service, and support programs.

2

Page 3: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Contents

Contact Us 6

Introduction 7About thisGuide 8Using the PDF Reader App 9Most Commonly Used Features 10Safety 11

Physical Features 13Buttons and Ports 14Power and Charging 17Maintenance 19

Home and Android Interface 20Swiping and Navigation 21Home Screen 22Top Notification Panel 24Apps 27Device Settings 29Sharing 31Saving a Screenshot 33

3

Page 4: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

LinkRunner G2 Application Settings 34Left-SideNavigation Drawer 35Configuring Test Settings 36Profiles and Jobs 44

LinkRunner G2 Tests and Results 47AutoTest 48Floating Action Button 63Switch Test 64Cable Test 66

Link-Live Cloud Service 71Getting Started in Link-Live 72

LinkRunner G2 Tools 75Reflector 76VLANMonitor 79Capture 81

Software Management 85Managing Files 86Updating Firmware 90Restoring Factory Defaults 92

4

Page 5: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Changing the Language 93

Additional Features 94Camera and Flashlight 95Wi-Fi Bluetooth USB Adapters 96

Specifications and Compliance 99Specifications and Compliance 100

5

Page 7: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

IntroductionThe LinkRunner G2 isan Android-basednetwork testing andtroubleshooting tool. Itallows networkingprofessionals to easilyverify networkconnectivity and PoEfunctionality and tovalidate cabling.LinkRunner G2 can alsoact as a packet reflectorfor performance testsrun by other NetAllytesters.

7

LinkRunner G2User Guide

Page 8: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

About this GuideThisUser Guide covers all the LinkRunner G2(LR G2) testing functionality and basic elements ofthe Android interface. This guide ismeant forusers knowledgeable about networking testingoperations.

8

Introduction

Page 9: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Using the PDF Reader AppA PDF reader application is pre-installed on yourLinkRunner G2device to allow easy navigation ofthis guide:

l Touch headings in theContents list to skipto the corresponding sections.

l Tap blue links to go to their destinations.Underlined blue links open externalwebsites.

l Tap the screen once to showor hide the apptoolbars at the top and bottom of theAdobe Reader screen.

l Tap the screen twice to zoom in or out.

l Touch the outline icon in the upper toolbar to view the guide outline and choose asection to read.

l Also, touch the outline icon to access anybookmarks or comments you have saved.

l Use the search feature to find specificterms.

9

Introduction

Page 10: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Most Commonly UsedFeaturesTouch the links below to skip to the instructionsfor the features listed:

"AutoTest" on page 48

"Cable Test" on page 66

"Switch Test" on page 64

"Configuring Test Settings" on page 36

"Home Screen" on page 22

"Reflector" on page 76

"VLANMonitor" on page 79

"Capture" on page 81

"Wi-Fi Bluetooth USB Adapters" on page 96

10

Introduction

Page 11: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

SafetyObserve the following safety information:

Use only the AC Adapter provided or Power overEthernet to charge the battery.

Use the proper terminals and cable for all con-nections.

To avoid possible electric shock or personal injury,follow these guidelines:

l Do not use the product if it is damaged.Before using the product, inspect the case,and look for cracked or missing plastic.

l Do not operate the product aroundexplosive gas, vapor, or dust,

l There are no serviceable parts. Do not try toservice the product.

l If this product is used in amanner notspecified by themanufacturer, theprotection provided by the productmay beimpaired.

11

Introduction

Page 12: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Safety Symbols

WWarning or Caution: Risk ofdamage to or destruction ofequipment or software.

X Warning: Risk of electrical shock.

j Not for connection to a publictelephone system.

* Class 1 Laser Product. Do notlook into the laser.

12

Introduction

Page 13: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Physical FeaturesThis User Guide sectionillustrates the ports and buttonson the LinkRunner G2 anddescribes charging andmaintenance.

13

LinkRunner G2User Guide

Page 14: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Buttons and PortsButton and port functions are described below.

Touchscreen

USB Port100/1000 BASE-X Fiber Port

RJ-45 LAN Port and Trasmit LEDs

RJ-45 Cable Test/ Wiremapping (WMAP) Port

Micro USB On-the-go

Port

Micro SD Card Slot

Charging Port

Kensington Lock

Camera and

Flash

VolumeButtons

Microphone

Speaker

Power Button and LED

Feature Description

100/1000 BASE-XFiber Port

Connects to an SFP adapter andfiber cableSupports 100BASE-FX and1000BASE-SX/LX/ZX

14

Physical Features

Page 15: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Feature DescriptionUSB Port Connects to anyUSB device

RJ-45 LAN Port(10/100/1000BASE-T)

Connects to the network usingan Ethernet cableCharges the unit if PoE isavailable

Transmit LEDsGreen LED lit: LinkedYellow LED flashing: Activity

Cable Test/WireMapping Input(WMAP)

Used for patch cable testing

Power Buttonand LED

Glows greenwhen the unit ispowered onGlows redwhen the unit ischarging

Charging Port Connects to AC adapter forcharging

Microphone Allows voice input

Camera andFlash

Captures images and acts as aflashlight

Micro SD CardSlot

Used for removable storageexpansion

Micro USB On-the-Go Port

Connects to a USB On-the-Gocord for communicating with aPCor USB peripheral

15

Physical Features

Page 16: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Feature DescriptionKensingtonLock Allows you to lock your unit

Volume Buttons Increase or decrease the audiovolume

Speaker Produces audio

16

Physical Features

Page 17: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Power and ChargingThe LinkRunner G2 contains a rechargeableLithium Ion battery. You can charge your LR G2using either AC or Power over Ethernet (PoE). TheLinkRunner G2doesnot charge via theUSB port.

See Buttons and Ports.

ChargingTo chargewith AC power, plug the included ACadapter into an AC outlet, and connect it to thecharging port on the device.

To chargewith PoE, connect the RJ-45 port on thedevice to a network switch with PoE available orwith a PoE injector.

NOTE: To charge via PoE, the LR G2must bepowered on or in sleep mode, and PoEmust beenabled in the test settings.

Charge the battery for 4-6 hours before first use.

Powering Onl Press the power button on the front of the

unit to power on the LinkRunner G2.

17

Physical Features

Page 18: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

l When the unit is on, press the power buttonto put it in sleep mode.

l To shut down, hold the power button forone second until the “Power off” dialog boxappears on the touchscreen, then tapPower off .

l To perform a hard power off (withoutshutting down the software), press and holdthe power button for five seconds.

The first time you turn it on, the LinkRunner G2testing application opens and begins testing yournetwork immediately. Connect the top RJ-45 LANport or 100/1000 BASE-X Fiber port to an activenetwork to begin receiving test results.

18

Physical Features

Page 19: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

MaintenanceTo clean the display, use a lens cleaner and a soft,lint-free cloth.

To clean the case, use a soft cloth that ismoist withwater or a weak soap.

WCAUTION: Do not use solvents or abrasivematerials thatmay damage the product.

19

Physical Features

Page 20: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Home and AndroidInterfaceThis section explains how to use thefeatures of the Android home screen anduser interface to navigate and organizeyour device.

The LinkRunner G2 interface appliesmany of the operations typical of anyAndroid device. Use swiping touchscreenmotions to navigate through screens andto drag down the top notification panel.

20

LinkRunner G2User Guide

Page 21: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Swiping and NavigationThe navigation actions you can perform to movethrough screens and panels in LinkRunner G2 arethe same as those you would use to navigate anAndroid phone or tablet.

SwipingTouch and drag your finger or "swipe" up, down,left, and right to move through pagesof theHome Screen and LinkRunner G2 testing applic-ation, scroll up or down in long screens, and pullout navigation drawers and panels.

Long PressingTouch and hold or "long press" files or applicationicons to reveal additional operations. Forexample, you can long press a file name in the FileManager Application to showoptions for movingor sharing the file.

21

Home and Android Interface

Page 22: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Home Screen

Tap this icon to view the User Guide.

Ta

This is the Notification Bar. Swipe down from the top of the screen to open the Top Notification Panel.

These are the default Home Screen apps. Touch to open.

NetAlly App Store

Device Settings

APPS Screen

Web Browser

File Manager

This is the Home Screen. Swipe left and right to move through pages.

Go to the APPS Screen to add app shortcuts to your Home Screen.

Returns to the previous screen.

Tap to view and close all open applications.

Returns to the Home Screen.

Opens the LinkRunner G2 testing application.

22

Home and Android Interface

Page 23: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Notification BarTheNotification Bar across the top of the screendisplays notification icons from the Androidsystem aswell as the following LinkRunner G2specific icons:

indicates access to Power over Ethernet forpower and charging.

indicates that a wired Ethernet connection is

established.

Touch and swipe down on theNotification Bar toopen the Top Notification Panel.

23

Home and Android Interface

Page 24: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Top Notification PanelThe Top Notification Panel contains notificationsfrom your device, such asdownloaded andinstalled applications, inserted hardware, capturedscreenshots, and available updates.

Swipe (touch and drag) down from the very topof the LinkRunner G2 screen to slide down thenotification panel.

24

Home and Android Interface

Page 25: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

l Touch a notification to open the related app,image, device options, or perform otheractions.

l Swipe left on a notification to dismiss it.l Touch the icon at the lower right of the

panel to dismiss all notifications.

Quick Settings PanelTheQuick Settings Panel is also accessed byswiping down from the top of the screen. You caneither swipe down twice, or touch the dark greytop portion of the notification panel to open it.

25

Home and Android Interface

Page 26: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Touch an icon in the panel to enable or disable thecorresponding feature. SeeWi-Fi Bluetooth USBAdapters for more information on using theoptionalWi-Fi and Bluetooth adapter accessory.

26

Home and Android Interface

Page 27: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

AppsTouch the APPS button on theHome Screento open the APPS screen.

Swipe left or touchWIDGETS to view theWIDGETSscreen.

Touch and hold (long press) an application's iconor awidget to add it to theHome Screen.

27

Home and Android Interface

Page 28: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

App StoreFrom theHome Screen or APPS Screen, open theNetAlly App Store to download Androidapplications specifically chosen to work with theLinkRunner G2 tester.

Touch thesearch icon tosearch for anApp.

To request that an App be added to theApp Store, visit the Apps page and select the Floating Action Button (FAB) at the lower right corner to Request an App.

28

Home and Android Interface

Page 29: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Device SettingsTo access the Android device settings, touch theSettings icon on theHome Screen.

Use the device Settings screen to adjust theLinkRunner G2display, sound, date/time, andlanguage, view installed applications and memorydevices, update your software, or reset to factorydefaults.

29

Home and Android Interface

Page 30: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Auto Power OffActivating theDevice Auto Power Off functionhelps to extend the LR G2's battery run time. Thedefault Auto Power Off setting isNever.

1. From the device Settings , selectDisplay.

2. On theDisplay settings screen, touch Deviceauto power off.

3. In the pop-up dialog box, select how longyou want the LR G2 to remain On with noactivity occurring. The LR G2willautomatically power off after the selectedperiod of inactivity haspassed.

You can also adjust the setting that controlswhenthe LR G2 goes into Sleep mode from theDisplaysettings screen.

30

Home and Android Interface

Page 31: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

SharingLinkRunner G2 allows you to “share” images andfiles like you would on an Android smart phone.When you see the Share icon , touch it to viewyour configured sharing options.

This example showsa captured screenshot noti-fication from the Top Notification Panel.

Touching SHARE opens the “Sharewith” pop-updialog, where you can chose a sharingmethod,such as email, messaging, or uploading to Link-Live.

31

Home and Android Interface

Page 32: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Sharing Files to Link-LiveFrom the “Sharewith” dialog box, touch theLinkRunner G2option to share a file to Link-LiveCloud Service along with your last test result orindividually to theUploaded Files page in Link-Live.

32

Home and Android Interface

Page 33: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Saving a ScreenshotOn the LinkRunner G2, press and hold the Powerbutton and the Volume Down button at thesame time for one second to save a screenshot ofthe current screen. (See Buttons and Ports forbutton locations.)

The LinkRunner G2 emits a beep and displays thecaptured screenshot notification in the Top Noti-fication Panelwhen it is successful.

33

Home and Android Interface

Page 34: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

LinkRunner G2Application Settings

This chapterdescribes theprocess forconfiguringtest settingsand savingthem to aprofile.

34

LinkRunner G2User Guide

Page 35: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Left-Side Navigation DrawerTo access the LinkRunner G2 testing applicationsettings, touch the navigation menu icon at thetop left of the LinkRunner G2 application screen.

Once claimed to Link-Live, the unit’s name and organization display here.

Tap here to open the Profiles screen.

Tap here to open the Settings screen.

Tap here to enter a new Job comment.

Tap here to use the Reflector tool.

Tap here to view information about your unit.

Tap here to use the VLAN Monitor tool.

Tap here to use the Packet Capture tool.

35

LinkRunner G2 Application Settings

Page 36: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Configuring Test SettingsThe LinkRunner G2 settings allow you to cus-tomize test settings for PoE, Speed/Duplex,Security, IP configuration, test targets, and otheraspects of AutoTest, Switch Test, and Cable Test.

To configure testing for your network, touch thenavigation menu icon at the top left of theLinkRunner G2 application screen, and then touchthe option.

Saving and Loading Profile SettingsThe header on the Settings screen displays thename of the current Profile.

To save your settings to a Profile (and view otheroptions), tap the save icon at the top right ofthe Settings screen.

36

LinkRunner G2 Application Settings

Page 37: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

To keep your revised settingswithout saving themto a profile, touch the back arrow icon to the left ofthe Settings screen header. Your new settings areapplied, and an asterisk * is added to the profilename to indicate unsaved changes.

See Profiles and Jobs for more on profiles.

Test Setting Descriptions

37

LinkRunner G2 Application Settings

Page 38: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

PoE

Enable PoE: Slide the toggle switch right to enablethe PoE test portion of AutoTest, and slide left todisable it.

Class: Touch the down caret to the right of thefield to select a PoE class setting to match yourswitch's (or PoE injector's) available class. TheLinkRunner G2 supports Cisco'sUPOE, which canprovide up to 51W, aswell as 802.3bt classes 5-8.Select the Injector option if you are using a non-IEEE injector.

NOTE: LR G2may not receive the total wattageadvertised by your switch or injector because ofpower loss over the cable.

LLDP: This field appears if Class 4 (25.50W) isselected. Class 4 LLDP must be enabled on theswitch for AutoTest to detect it successfully.

NOTE: If a switch doesnot support LLDP and theLLDP setting is enabled on LR G2, LLDP nego-tiation will fail, but it will not affect the rest of theAutoTest.

Request Power (W): This field appears if theUPOE class is selected. Touch the field to open a

38

LinkRunner G2 Application Settings

Page 39: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

pop-up keyboard and enter the requestedwattage.

Enable TruePower™: Slide the toggle switch rightto enable the TruePower feature. TruePower val-idates that the Switch (PSE) and cabling canprovide the requested power under load.

Connect

Speed/Duplex: Select the speed and duplexoption that you want to test your network against.The default is Auto negotiation.

Security

802.1X Authentication: Slide the toggle switchright to enable 802.1X authentication.

EAP Type: This field appears if 802.1X authen-tication is enabled. Touch the down arrow tochoose the correct type. Additional security fields,such asUsername and Password, display asrequired.

IP

IPv6: Slide the toggle switch right to enable IPv6.

39

LinkRunner G2 Application Settings

Page 40: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

IP Configuration: Touch the down caret toswitch between DHCP and Static IP configuration.If you choose static, the IP Address, SubnetMask,and other IP fields display. Touch each field toopen a pop-up number pad and enter theaddresses asneeded. Touch OK to save them.

DHCP Option: Slide the toggle switch right toselect Option 150, 43, or 60.Options 43 and 150request the IP address of a key server, such as aVoIP TFTP server or Wireless LAN Controller.Option 60 allows the user to enter a Vendor ClassIdentifier string, which informs theDHCP server ofthe type of client.

Proxy: Slide the toggle switch right to enableProxy settings.When proxy is enabled, theAddress, Port, Username, and Password fieldsappear. Touch each field to open a pop-upkeyboard and enter the appropriate data. TouchOK to save your entries.

Targets

You can add an unlimited number of test targetsby entering the IP address or a URL and specifyingeither an ICMP Ping or TCP Port Open test foreach target.

40

LinkRunner G2 Application Settings

Page 41: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Address: When AutoTest runs, the LinkRunnerG2 attempts to reach the target address entered inthis field. The default isGoogle.com.

l Touch the Address field to open a pop-upkeyboard and enter a new address.

l Touch the action overflow icon to the rightof the Address field to either Delete thetarget address field from AutoTest orDuplicate the current target address entry.

Port: This is the port the LinkRunner G2uses toconnect to the target address for a TCP Port Opentest. The default is 80. Touch the Port field to opena pop-up number pad and enter a newportnumber. Touch OK to save it.

Ping: Slide the toggle switch right to run an ICMPPing test to the target address. The Port field dis-appearswhen this toggle is enabled.

+ ADD TARGET: Touch to add additional targetaddress fields.

Test

Stop After: This setting directs AutoTest to stoptesting after the selected test step. The excludedtest cardswill not appear on the AutoTest screen.

41

LinkRunner G2 Application Settings

Page 42: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Link-Live: Slide the toggle to the left to disableuploading of AutoTest results to Link-Live andremove the Link-Live Upload card from theAutoTest screen.

VLAN

Enable VLAN: Slide the toggle to the right toenable VLAN settings.Once enabled, VLAN ID andVLAN Priority fields appear. Touch these fields toopen a pop-up number pad and enter the correctID and priority. Touch OK to save them.

NOTE:When VLAN is enabled, the VLAN Test cardappears on the AutoTest screen.

User Defined MAC

Enable User Defined MAC: Slide the toggle to theright to enable a user-defined MAC address.Whenenabled, the User Defined MAC field turns fromgrey to black.

User Defined MAC: If enabled, touch this field toopen a pop-up keyboard and enter your MACaddress. Touch OK to save it.

42

LinkRunner G2 Application Settings

Page 43: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

General SettingsCable Unit: Touch the down caret to selecteither meters or feet for the Cable Test unit ofmeasurement.

Default Settings: Tap this field to restore theLinkRunner G2 testing application to factorydefault profile settings. A dialog box will ask you toconfirm Yesor No before it restores.

NOTE: See Restoring Factory Defaults for instruc-tions on resetting your entire LR G2device tofactory default configuration.

43

LinkRunner G2 Application Settings

Page 44: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Profiles and JobsA Profile is a saved configuration of test settings.The currently active Profile's name is displayed inthe Left-SideNavigation Drawer and at the top ofthe Settings screen, as shown below.

The header on the Settings screen displays thename of the current Profile.

An asterisk * next to the Profile name indicatesthat you have adjusted settings since the Profilewas last saved.

To save your settings to a Profile (and view otheroptions), tap the save icon at the top right ofthe Settings screen.

Profile saving options include the following:

l Save saves the current settings to thecurrently loaded profile.

l Save As saves a newProfile with the currentsettings and opens a pop-up keyboard for

44

LinkRunner G2 Application Settings

Page 45: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

entering a newname. Touch SAVE to savethe newProfile Name.

l Load opens the Profiles screen.

Profiles ScreenThis screen displays a list of all the saved Profiles.

NOTE: The "Link-Live" profile is a profile createdfrom Link-Live Cloud Service and downloaded toLinkRunner G2. A single profile can be created inLink-Live and pushed to many LinkRunner G2s.

Touch a Profile's name to load its saved settings.

Touch the overflow action icon next to a Profilename to Delete, Rename, or Duplicate it.

If you choose to duplicate a Profile, a pop-updialog prompts you for a NewProfile Name.Touch SAVE to save the newname.

45

LinkRunner G2 Application Settings

Page 46: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

JobsJobs are comments that are added to the testresults uploaded to Link-Live Cloud Service. Theyhelp you organize test results.

To save a Job comment, touch the navigationmenu icon at the top left of the LinkRunnerG2 application screen, and then touch the Jobfield to open a dialog box and the pop-upkeyboard. Touch OK tosave the new Jobcomment.

If the Job saved on yourLinkRunner G2unitmatches a named folderin your Link-Liveorganization, the test results are automaticallysorted into that folder.

If you want to create a new folder in Link-Live andsave your test results to it, simply add a forwardslash / at the beginning of the Job name, as shownin the image on this page.

46

LinkRunner G2 Application Settings

Page 47: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

LinkRunner G2 Testsand ResultsThe LinkRunnerG2 features amain AutoTestscreen, a SwitchTest screen, and aCable Test screen.Swipe left andright to movethrough the threetest screens.

This User Guidechapter describeseach test sectionand its results.

47

LinkRunner G2User Guide

Page 48: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

AutoTestAutoTest is a set of wired tests and measurementsthat run automatically when you turn on yourLinkRunner G2. To run AutoTest with your unitalready powered on, connect the RJ-45 port or theFiber port on the top of the LinkRunner G2 to anactive network switch. Touch theNetAlly logo atthe bottom of the screen to open the LinkRunnerG2 testing app.

Each individual testis presented on itsown card. Tap thedown caret onthe right side of acard to expand andview detailedresults.

The AutoTest tabheader shows thenumber of failedtests (if any) in redand the number ofwarnings in yellow.In the image, the

48

LinkRunner G2 Tests and Results

Page 49: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Link test has awarning, and theDNS test hasfailed. The test icons also turn green, yellow, or redbased on the test results.

To restart testing at any time, tap the refresh iconat the top right of the LR G2 app screen.

Test Settings are described in the LinkRunner G2Application Settings chapter.

The following subsectionsdescribe each card inthe AutoTest.

49

LinkRunner G2 Tests and Results

Page 50: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Power over Ethernet (PoE) TestThe header of the PoE Test card displays themeasured Voltage, Class, and Wattage.

The PoE card displays additional TruePower™results only if TruePower is enabled in thePoE Settings. TruePower applies a load equivalentto the selected class to mimic a Powered Device(PD).

50

LinkRunner G2 Tests and Results

Page 51: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Detailed PoE Results

PoE Result DescriptionRequestedClass

Class selected in the PoE testsettings

Received Class Class acknowledgment receivedby the LRG2 from the switch

TruePower™Power Measuredwattage with load

UnloadedVoltage Measured voltage without load

TruePower™Voltage Measured voltage with load

PSE Type

Switch's advertised PowerSourcing Equipment (PSE) type.Recognized types are 1 – 4,LTPoE++, Cisco UPOE, and PoEInjectors. PSEs supporting UPOEare classified under Type 2. If thetype cannot be determined, 1/2is displayed.

Spare Pair Status of spare pair negotiationfor UPOE (true or false)

Negotiation Negotiation type for UPOE andClass 4 (UPOE or LLDP)

Positive Positive PoE cable pair IDs

Negative Negative PoE cable pair IDs

51

LinkRunner G2 Tests and Results

Page 52: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Link TestThe Link Test card header displays the advertisedspeed and duplex in grey and the detected speedand duplex in black text.

If the Link icon turns yellow as shown on page 48,LR G2hasdetected a downshift from themaximum advertised speed.

Detailed Link Results

Link Result Description

Advertised Speed Speed capability as reportedby the switch

52

LinkRunner G2 Tests and Results

Page 53: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Link Result Description

Actual Speed Link speed asmeasured byLinkRunner G2

AdvertisedDuplex

Duplex capabilities reportedby the switch

Actual Duplex Duplex in use as detected byLRG2

Rx Pair Link receive pair

Polarity Link polarity: normal orreversed

Interface Link interface: Copper/RJ-45port or SFP/Fiber port

53

LinkRunner G2 Tests and Results

Page 54: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

VLAN TestThe VLAN Test card only appears if VLAN isenabled in the LinkRunner G2Application settingsor if VLAN-tagged traffic is detected duringAutoTest.

Detailed VLAN Results

VLAN Result Description

VID VLAN ID selected in the LRG2Application settings

PRI VLAN Priority set in the LRG2Application settings

Seen Number of VLANs detectedduring AutoTest

VIDs VLAN IDs detected duringAutoTest

54

LinkRunner G2 Tests and Results

Page 55: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Switch TestThe Switch Test card header displays the dis-covered switch name or simply "Ethernet" if noswitch name could be discovered.

If LinkRunner G2wasunable to obtain switchinformation from the first AutoTest run, touchREFRESH to capture and display the next portadvertisement/xDP (LLDP or CDP).

Detailed Switch Results

Switch Result DescriptionPort Discovered port name

VLAN Discovered VLAN ID number

55

LinkRunner G2 Tests and Results

Page 56: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Switch Result Description

Voice VLAN Discovered Voice VLAN IDnumber

Name Discovered switch's name

Model Discovered switch's model

Address Discovered switch's IP address

Type Switch type: CDP or LLDP

56

LinkRunner G2 Tests and Results

Page 57: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

DHCP TestTheDHCP Test card header displays theDHCPserver's IP address.

Detailed DHCP Results

DHCP Result Description

Discover Status of the discovery framebroadcast from LRG2

Offer timeTime betweenwhen LRG2sent the discovery andreceived an address offerfrom the DHCP server

57

LinkRunner G2 Tests and Results

Page 58: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

DHCP Result Description

Request Status of the address requestsent from LRG2

ACK TimeTime between LRG2 sendingthe request and receiving theacknowledgement from theDHCP Server

Server IP address of the DHCP server

Subnet IP address of the subnetwhere LRG2 is testing

Option 150/43IP address returned by theDHCP server if a DHCP optionis enabled in the test settings

Lease TimeTime the IP address is leasedto the LRG2 by the DHCPserver

58

LinkRunner G2 Tests and Results

Page 59: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

DNS TestTheDNS test card header displays theDNS IPaddresses.

Expand theDNS card to view the response timesfrom each DNS server. The LR G2pings each DNSserver three times and displays the response timefrom each Ping.Up to four DNS servers arecaptured and displayed on theDNS test card.

59

LinkRunner G2 Tests and Results

Page 60: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Gateway TestTheGateway Test card displays the gateway's IPaddress.

The LR G2pings the gateway three times anddisplays the response time from each Ping.

Touch CONTINUOUS to run a continuousmon-itoring test to the gateway. A dialog box appearsand displays the continuousPing test results untilyou close the dialog box.

60

LinkRunner G2 Tests and Results

Page 61: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Target TestsThe Targets Tests are user-assignable endpointsthat LR G2 attempts to connect to each timeAutoTest runs. Target tests are either Ping or TCPPort Open tests.

See Targets in the Configuring Test Settingschapter.

The Target Test card header shows theURL or IPaddress of the target and the port number ifapplicable.

The expanded Target Test card shows the IPaddress of the target, the type of test (Ping or

61

LinkRunner G2 Tests and Results

Page 62: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

TCP), and the time for each response received byLR G2.

Touch CONTINUOUS to run a continuousmon-itoring test to the target. A dialog box appears anddisplays the continuousPing or TCP Port Opentest results until you close the dialog box.

Link-Live UploadThe Link-Live test card indicateswhether theLinkRunner G2was able to upload your testresults to the Link-Live Cloud Service. Refer to thechapter on Link-Live Cloud Service for moreinformation.

62

LinkRunner G2 Tests and Results

Page 63: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Floating Action ButtonThe Floating Action Button or FAB appears onmany of the Android and LinkRunner G2 applic-ation screens. It offers additional actions related tothe current screen or test.

Tap or click the FABonce to view the addi-tional options avail-able. Then, touch thepop-up button for theaction you want toperform.

For example, theAutoTest FAB allowsyou to add a picture or a comment to the lastAutoTest result, which is automatically uploadedto Link-Live at the completion of each test.

63

LinkRunner G2 Tests and Results

Page 64: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Switch TestThe Switch test tab displays the information fromthe nearest switch by locating the port advert-isement (xDP) on the first few packets seen byLinkRunner G2.

Switch Nameand Model

Switch IP address

Port and slot number

Port VLAN IDs

Switch Test FABSw

Speed and Duplex: Advertised/DetectedSpAdAd

PoE Voltage and Wattage: Advertised/DetectedWa

PoE Positive and Negative cable pairs

Blue line for Copper/LANOrange line for Fiber/SFP

64

LinkRunner G2 Tests and Results

Page 65: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Tap the FAB on the Switchtest screen to access thefollowing actions:

Refresh xDP: Capturesand displays the next portadvertisement (CDP orLLDP).

Flash Port: Causes theswitch to flash the LED on the port where theLinkRunner G2 is connected. Touch and drag theslider between Slow and Fast to differentiate itfrom the other switch port LED flash rates.

To restart testing at any time, tap the refresh iconat the top right of the LR G2 app screen.

65

LinkRunner G2 Tests and Results

Page 66: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Cable TestThe Cable test can help you determine cablelength and status, wiremap patch and structuredcabling, and locate cables. The Cable test tab canperform tests using the configurationsdescribedin this section.

With an unterminated cable test, you can determ-ine length, shorts, and splits and locate opens.With a terminated cable test using the internalWireMapping Port or aWireView accessory, youcan identify cable length, shorts and opens, splitpairs, crossover cables, and normal or negativepair polarity.

NOTE: LR G2 cannot perform a cable test on acable that is connected to a switch.

To restart testing at any time, tap the refresh iconat the top right of the LR G2 app screen.

Refer to Buttons and Ports as needed.

66

LinkRunner G2 Tests and Results

Page 67: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Open Cable TDR TestingConnect an open cable (unterminated) into thetop RJ-45 port to measure its length and view anyshorts, opens, or splits.

67

LinkRunner G2 Tests and Results

Page 68: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Patch Cable TestingConnect a cable from the top LinkRunner G2RJ-45LAN port into the side RJ-45 Cable Test/WireMapping Port to view its length and wiremapping,including any faults.

68

LinkRunner G2 Tests and Results

Page 69: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Wire MappingConnect the top RJ-45 port to a cable terminatedwith an externalWireView Cable ID accessory. AWireView#1 is included with your LinkRunner G2.AdditionalWireViews2-6 are available forpurchase.

TheWireMapper Cable Test displays the numberof theWireView attached, unless a cable faultprevents LR G2 from detecting theWireView.

A cable/drop port can be traced using aWireViewup to 300 ft/100m from the LinkRunner G2.

69

LinkRunner G2 Tests and Results

Page 70: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

* IntelliTone is a trademark of Fluke Networks.

Using the Tone FunctionYou can also trace a cable using a FlukeNetworks*IntelliTone™ Probe, or any analog probe, and theTone function.

Connect a cable into thetop RJ-45 port, touch theFAB, and select theappropriate Toneoption for your probe.The LinkRunner G2emits the tone throughthe cable, and the probedetects it, allowing youto trace thewire or locate it in the switch closet.

70

LinkRunner G2 Tests and Results

Page 71: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Link-Live CloudServiceLink-LiveCloud Serviceis a free,online systemfor collecting,tracking,organizing,and reporting your test results, which areautomatically uploaded once yourLinkRunner G2 is claimed.

Claiming your LR G2 to Link-Live alsoallows you to update the firmware on yourunit and access applications in theNetAlly App Store that have beenspecifically chosen to work withLinkRunner G2.

71

LinkRunner G2User Guide

Page 72: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Getting Started in Link-LiveTo start, create a user account.

On the LinkRunner G2 UnitIn the LinkRunner G2 testing application on yourLR G2unit, touch the navigation menu icon atthe top left of the screen, and touch CLAIM NOWin the navigation drawer.

In Link-LiveThe first time you sign in to Link-Live, a pop-upwindow appears, prompting you to claim a device.

If you already have a user account and otherdevices claimed to Link-Live, navigate to theUnitspage from the left side navigation drawer, and

72

Link-Live Cloud Service

Page 73: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

click theClaim Unit button at the lowerright corner of the screen.

Then, select the LinkRunner G2 image,and follow the claiming instructions on the Link-Livewebsite.

Once your LR G2 is claimed to the Link-Live Cloud,it will automatically upload your AutoTest resultseach time you run AutoTest.

From the LR G2, you can also upload a testcomment and a picturewith your test resultsusing the AutoTest FAB and automatically sortyour results into folders in Link-Live using the Jobsfeature. If your LR G2 is not connected to an activenetwork, the test result and any photos orcomments are stored in memory and uploadedonce a connection is established.

For more information on how to use Link-Live,click or touch the navigation menu icon at thetop left of the Link-Livewebsite, and select

.

73

Link-Live Cloud Service

Page 74: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

UnclaimingTo unclaim your LR G2 from Link-Live on thedevice, open theAbout section from the Left-SideNavigation Drawer, and selectUNCLAIM.

74

Link-Live Cloud Service

Page 75: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

LinkRunner G2 ToolsThe LR G2 also features a performancetest Reflector, a VLAN Monitor, andpacket Capture tools. These are explainedin the following section.

Access the tools fromthe Left-SideNavigation Drawer.

75

LinkRunner G2User Guide

Page 76: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

ReflectorThe Reflector feature allows the LinkRunner G2 toact as a reflector for performance tests conductedby other NetAlly testing devices.

To open the Reflector screen, touch the navigationmenu icon at the top left of the LinkRunner G2application screen, and then touch Reflector.

IP Address:When you enter the Reflector screen,the LR G2 automatically obtains and displays its IPaddress in the top field.Use this IP address toconnect to the LR G2 from your main per-formance testing device.

76

LinkRunner G2 Tools

Page 77: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

MAC Address: LinkRunner G2'sMAC address

Packet Type: Touch the down caret to selectthe packet type filter setting. TheMAC + NetAllysetting tells LR G2 to reflect only packetswith a des-tination MAC address thatmatches the LR G2'sown MAC address and NetAlly payload.

Swap: Touch the down caret to select a swapsetting.MAC + IP tells the LR G2 to swap thesource and destination MAC and IP addresses forpackets that are reflected back to LR G2.

NOTE: The recommended settings are PacketType: MAC + NetAlly and Swap: MAC + IP. OtherReflector settingsmay cause undesired traffic onyour network.

77

LinkRunner G2 Tools

Page 78: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

To start the Reflector feature, tap the FABon this screen. Tap it again to stop theReflector.

While running, the Reflector screen displays thebytes received and reflected.

See the user documentation for your mainNetAlly performance tester for information onsetup and viewing results.

78

LinkRunner G2 Tools

Page 79: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

VLAN MonitorThe VLANMonitor tool displays the real-timetraffic on any Virtual LANsdetected.

79

LinkRunner G2 Tools

Page 80: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

The top nine VLANswith the highest traffic are dis-played as colored portions of the pie chart, andthe rest are grouped into the "Others" category.

80

LinkRunner G2 Tools

Page 81: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

CaptureUsing the Packet Capture tool, you can savepacket captures, upload them to Link-Live, andthen download for analysis on a PC.

NOTE: You must have aMicro SD card inserted inthe LR G2 to run and save packet captures. SeeUsing aMicro SD Card.

To open the Capture screen, touch the navigationmenu icon at the top left of the LinkRunner G2application screen, and then selectCapture.

81

LinkRunner G2 Tools

Page 82: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Filename: Capture files are automatically namedusing the date and time. Touch this field to enter acustom name.

File Size: Touch this field to specify a size for thecapture file. The default is 1MB. The capture stopswhen the captured file reaches this size.Whencapture is running, the File Size field displays thecurrent file size asdata is captured.

Frame Slice Size: Touch this field to select aspecific frame slice size for your capture. Thedefault isUnlimited.

Frames:When capture is running, the Framesfield displays the number of captured frames.

SD Space:When capture is running, this fieldappears and shows the remaining space on theSD card.

Saving and Accessing Capture FilesTo start Capturing, tap the FAB on thisscreen. Tap it again to stop capturingpackets.

82

LinkRunner G2 Tools

Page 83: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Once a capture is completed, a notificationappears in the Top Notification Panel andprovides options for sharing the capture file.

If captured files are saved on the LR G2, theCaptured Files field appears on the Capturescreen. Touch the field to open the Captured Filesscreen.

Tap the action overflow icon to the right of thefilename to Delete, Rename, or Share the capturefile to Link-Live.

83

LinkRunner G2 Tools

Page 84: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

You can also access all captures and other filesfrom the FileManager Application. Capture filesare saved on your inserted SD card.

84

LinkRunner G2 Tools

Page 85: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Software ManagementThis chapterexplains how tosave andtransfer filesusing yourLinkRunner G2.

85

LinkRunner G2User Guide

Page 86: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Managing FilesLinkRunner G2 supports severalmethods formanaging files, consistent with other Androiddevices. Images, documents, applications, andother files live in a folder hierarchy, where you cancopy,move, and paste them between folders orto external storage locations.

See also Swiping and Navigation.

File Manager ApplicationThe FileManager app allows you to access the filessaved on your LR G2. Touch the icon at thebottom of theHome Screen to open the FileManager.

Touch a folder orfile in the FileManager to open it.

Long press onfolders or files inthe FileManager toview additional filemanagementoperations.

86

SoftwareManagement

Page 87: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Tap the action overflow icon whereever itappears in the FileManager to see even moreactions, such as to create a new folder or add a fileto theHome Screen.

Using a Micro SD Card1. To use aMicro SD card for storage, insert it

into theMicro SD card slot on the right sideof your LinkRunner G2. A Micro SD card iconappears in the notification bar at the top

of the LR G2 screen.

2. On the LR G2 screen, pull down the TopNotification Panel to reveal the "New SD carddetected" notification.

3. Touch SET UP.

4. On the Set up your SD card screen, selectUse as portable storage to use theMicroSD card for transferring files to and fromyour LinkRunner G2.

87

SoftwareManagement

Page 88: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

5. Touch theNEXT button at the bottom left ofthe screen.

6. Touch DONE.

7. The SD card storage location is nowavailable from the FileManagerapplication, and a notification appears in theTop Notification Panel alerting you that it isconnected.

Using a USB DriveInsert a USB flash drive into theUSB port on thetop of the LR G2.

TheUSB storage location is now available fromthe FileManager application, and a notificationappears in the Top Notification Panel alerting youthat it is connected.

Using a Micro USB to USB Cable1. Plug aMicro USB connector side of a USB

cord into theMicro USB port on the rightside of the LR G2, and plug theUSB side intoa PC or tablet. (If the LR G2 folder doesnotopen automatically on your PC screen,continue following the stepsbelow.)

88

SoftwareManagement

Page 89: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

2. On the LR G2 screen, slide down the TopNotification Panel to view the notifications.

3. Then, touch USB for File Transfer.

4. In the pop-up dialog, tap the File transfersoption.

5. On your PC or tablet, navigate to theLinkRunner G2 folder in the file system ifnecessary. From there, you can move, copy,and paste files to and from the LinkRunnerG2's file system.

89

SoftwareManagement

Page 90: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Updating FirmwareYour LinkRunner G2 accesses software updatesfrom the Link-Live Cloud Service.

NOTE: You must create an account and "claim"your LinkRunner G2unit to the Link-Live CloudService for the LR G2 to find and downloadsoftware updates. SeeGetting Started in Link-Live.

1. To check for updates through theDeviceSettings, touch the Settings icon at thebottom of theHome Screen.

2. On the Settings screen, scroll down to theSystem section, and touch About Tester.

3. At the top of the About Tester screen, touchCHECK FOR UPDATES.

4. On the System Updates screen, touch theCheck for Updates button. If a newsoftware version is available, it displaysbelow the Current version shown.

5. Tap the new version number, and thentouch Download to download and installthe latest software.

90

SoftwareManagement

Page 91: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

6. Once the new software is downloaded,touch Install to install it.

91

SoftwareManagement

Page 92: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Restoring Factory DefaultsWCAUTION: This operation will delete all testresults, installed applications, and saved files, andreset device settings to the factory default state.Make sure to back up any files you desire to keep.

1. To access the Android device settings, touchthe Settings icon at the bottom of theHome Screen.

2. On the Settings screen, scroll down to thePersonal section, and touch Reset.

3. On the Reset screen, touch Factory datareset.

4. At the bottom of the Factory data resetscreen, touch RESET LINKRUNNER G2.

5. The device asks you to confirm oncemorethat you want to restore all defaults. TouchERASE EVERYTHING to do so.

The device restartswith factory default settings.

92

SoftwareManagement

Page 93: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Changing the Language1. To change the language on the LinkRunner

G2 interface, go to theDevice Settings bytouching the Settings icon at the bottomof theHome Screen.

2. On the Settings screen, scroll down to thePersonal section, and touch Language &input.

3. On the Language& input screen, touchLanguage.

4. Touch the name of your desired language inthe list. The LR G2displays the chosenlanguage.

93

SoftwareManagement

Page 94: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Additional FeaturesThis chapter describes how to use thebuilt-in camera, flashlight, and optionalEdimax adapters for Wi-Fi/Bluetooth/BLEsupport.

94

LinkRunner G2User Guide

Page 95: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Camera and FlashlightThe camera lens and flash are located on the backof the LinkRunner G2unit. (See Buttons andPorts.)

The Camera application is located in the APPSscreen. Touch the Appsbutton on theHomeScreen to open the APPS screen. From there, youcan touch and hold on the camera app icon, andthen place the icon on aHome Screen page forquick access.

Additionally, once an AutoTest has completed, theFloating Action Button appears and provides theoption of opening the camera application to takeand attach a picture to the AutoTest results.

The Flashlight feature can be accessed from theQuick Settings Panel by swiping down twice fromthe top of the LR G2 screen.

95

Additional Features

Page 96: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Wi-Fi Bluetooth USB AdaptersLinkRunner G2 supports two Wi-Fi/Bluetooth USBAdapters, which are available for purchase sep-arately: the Edimax N150 EW-7611ULB andEdimax AC1200 EW-7822ULC.

You can use these adapters to connect tonetworkswirelessly for browsing the internet,transferring files, using email, and running applic-ations.

Plug theUSB Adapters into theUSB port on thetop of your LinkRunner G2.

Connecting to Wi-Fi or Bluetooth1. On the LR G2 screen, swipe down from the

top of the screen twice to open theQuick Settings Panel.

2. At any time, tap the icons aboveWi-Fi orBluetooth to quickly enable or disableWi-Fior Bluetooth capability.

96

Additional Features

Page 97: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

3. Tap to open the list of availableWi-Finetworks.

4. Touch a network's name to connect to it.

Optionally, touchMORE SETTINGS to open theWi-Fi device settings screen and manageWi-Finetworks there.

Once aWi-Fi network or Bluetooth device isselected, its name displays below theQuickSettings icon.

97

Additional Features

Page 98: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

To connect to a Bluetooth device, touchto scan for available Bluetooth

devices.

MORE SETTINGS opens the Bluetooth devicesettings screen aswell.

On the Bluetooth or Wi-Fi settings screen, touchthe action overflow icon to Refresh thescanning process and view other options.

98

Additional Features

Page 99: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Specifications andComplianceRequired compliance information iscontained in this chapter.

99

LinkRunner G2User Guide

Page 100: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Specifications and Compliance

Dimensions 3.8 in x 7.7 in x 1.6 in (9.7 cm x 19.6cm x 4.1 cm)

Weight 18 oz (0.51 kg)

Battery Rechargeable lithium-ion batterypack (3.6 V, 6 Ah, 21 Wh)

Battery LifeTypical operating life is 4 hours(infinite on PoE). Typical chargetime is 3 hours.

Display 5.0 in color LCDwith capacitivetouch screen (480 x 854 pixels)

Keypad 1-key elastomeric (power only)

Host Inter-face Micro USB On-the-Go port

USB Port USB 2.0 Type Aport

SD Card Port Supports Micro SD

MemoryApproximately 3 GB available forstoring test results and user applic-ations

Media Access 10BASE-T, 100BASE-TX, 1000BASE-T (IEEE-802.3) and PoE

Cable TestPair lengths, opens, shorts, splits,crossed, straight through, andcable ID

100

Specifications and Compliance

Page 101: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

ToneGenerator

Digital tone: [455 KHz]; Analogtones: [400 Hz, 1 KHz]

PortsRJ-45 copper port100/1000BASE-X fiber adapterport

External ACAdapter/Charger

AC input 90-264 Vac 48-62 Hz inputpower DCoutput 15Vdc at 2 amps ORRJ-45 via PoE

LEDS 2 LEDs (Transmit and Link Indic-ators)

Environmental Specifications

Operating Tem-perature

32ºF to 113ºF (0ºC to +45ºC)NOTE: The battery will notcharge if the internal tem-perature of the Tester is above122ºF (50ºC).

Operatingrelative humidity(% RH withoutcondensation)

90% (50ºF to 95ºF; 10ºC to 35ºC75% (95ºF to 113ºF; 35ºC to45ºC)

Storage Tem-perature -4ºF to 140ºF (-20ºC to +60ºC)

Shock and vibra-tions

1 m drop test, Random, 3.8grms, 5 Hz-500 Hz (Class 2)

101

Specifications and Compliance

Page 102: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Safety IEC 61010-1:2010: Pollutiondegree 2

Altitude Operating: 4,000 m; Storage:12,000 m

EMCIEC 61326-1:2013: Basic Elec-tromagnetic Environment;CISPR 11: Group 1, Class A

Group 1: Equipment has intentionally generated and/oruses conductively-coupled radio frequency energy thatis necessary for the internal function of the equipmentitself.Class A: Equipment is suitable for use in all estab-lishments other than domestic and those directlyconnected to a low-voltage power supply network thatsupplies buildings used for domestic purposes. Theremay be potential difficulties in ensuring electromagneticcompatibility in other environments due to conductedand radiated disturbances.

102

Specifications and Compliance

Page 103: netAlly LINKRUNNER™ G2 Manual - Test Equipment Depot · 2019. 11. 19. · UserGuide May29,2019. Legal Notification Use of this product is subject to the End User License Agree-ment

Certifications and ComplianceStandards

P Conforms to relevant EuropeanUniondirectives.

Conforms to relevant Australian Safetyand EMC standards.

�Complies with 47 CFR Part 15 require-ments of the U.S. Federal Com-munications Commission.

� Certified byULNorth America SafetyStandards.

à Conforms to relevant South KoreanEMCStandards.

Additional South Korean EMC StandardsInformationElectromagnetic Compatibility. Applies to use inKorea only. Class A Equipment (Industrial Broad-casting & Communications Equipment) [1]

[1] This product meets requirements for industrial(Class A) electromagnetic wave equipment and the selleror user should take notice of it. This equipment isintended for use in business environments and is not tobe used in homes.

103

Specifications and Compliance