Network Infrastructure. IT Supporters Update – 26 June 2007. Contents. Network overview Server connectivity upgrade Wireless network changes Subnet changes DNS and DHCP infrastructure. Network overview. Two separate networks readingConnect (for halls of residence) Campus network - PowerPoint PPT PresentationTRANSCRIPT
24 April 2023 © University of Reading 2006 www.reading.ac.uk
Network InfrastructureIT Supporters Update – 26 June 2007
2To put your footer here go to View > Header and Footer
Contents• Network overview• Server connectivity upgrade• Wireless network changes• Subnet changes• DNS and DHCP infrastructure
3To put your footer here go to View > Header and Footer
Network overview• Two separate networks
– readingConnect (for halls of residence)– Campus network
• Both networks share common border area• Focus on campus network
– Each building connected at a minimum of 1Gbit/s– Except for Bulmershe and halls of residence
• New router to be installed at Bulmershe to make better use of existing switches and infrastructure
• Halls of residence too far away for more than 100Mbit/s
4To put your footer here go to View > Header and Footer
Network overview• Border network forms connection between campus
network, readingConnect and JANET• Two JANET connections
– Each 1Gbit/s over long-range fibre– Diverse routes– Endpoints over 1.5Km apart
• Fully resilient• Traffic split across both links during normal
operation– Campus traffic one way– readingConnect traffic goes the other
5To put your footer here go to View > Header and Footer
Network overview• 10616 IP addresses in use by 8964 unique hosts• 1844 hosts registered but not seen on network
since Feb– These will be removed at the end of July– A list will be distributed to IT Supporters at start of July
• Monthly stats (2 hour average) show:– 92.81Mbit/s peak traffic flow from JANET to campus– Average flow of 27.17MBit/s inbound and 15.39MBits/
outbound– 95th percentile is 73.02Mbit/s
6To put your footer here go to View > Header and Footer
3804lpine
1
2
3
4
DIAGSTATUS
AB
PSU CONSOLE MODEM MGMT
PCMCIALINK\ACTIVE
SMM45014
i
GM-4X45112
i
STATUS
1000 BA SE- X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
FM-32T45210
i
STATUS
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- L INK OK
- DISABLED
10/100 B ASE-T XMD I-X
4
20
1
17
8
24
5
21
12
28
9
25
16
32
13
29
1 2 3 4 5 6 7 8
10 11 12 13 14 15 16
18 19 20 21 22 23 2426 27 28 29 30 31 32
1725
9
FM-32T45210
i
STATUS
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- L INK OK- DISABLED
10/100 B ASE-T XMD I-X
4
20
1
17
8
24
5
21
12
28
9
25
16
32
13
29
1 2 3 4 5 6 7 8
10 11 12 13 14 15 16
18 19 20 21 22 23 24
26 27 28 29 30 31 32
17
25
9
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
CONSOL E
49 50
MGMT
PORT 49
PORT 50
Extreme Networks Summit48siR
1 2 3 4 A B 5 6 7 8
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
CO NSOL E
MGM T
COMPACTFL ASH
MSM-1XL60016
MST
REN
V
SYS
ERR
CO NSOL E
MGM T
COMPACTFL ASH
MSM-1XL60016
MST
REN
V
SYS
ERR
G60X61010
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
DS
G60X61010
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
DS
3804lpine
1
2
3
4
DIAGSTATUS
AB
PSU CONSOLE MODEM MGMT
PCMCIALINK\ACTIVE
SMM45014
i
GM-4X45112
i
STATUS
1000 B ASE -X
4321
GREENAMBER
FLASHING ORANGE
- ACTIVITY- LINK OK
- DISABLED1 2 3 4
FM-32T45210
i
STATUS
GREENAMBER
FLASHING ORANGE
- ACTIVITY- L INK OK
- DISABLED
10/100 B ASE-T XMD I-X
4
20
1
17
8
24
5
21
12
28
9
25
16
32
13
29
1 2 3 4 5 6 7 8
10 11 12 13 14 15 16
18 19 20 21 22 23 24
26 27 28 29 30 31 32
17
25
9
FM-32T45210
i
STATUS
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- L INK OK
- DISABLED
10/100 B ASE-T XMD I-X
4
20
1
17
8
24
5
21
12
28
9
25
16
32
13
29
1 2 3 4 5 6 7 8
10 11 12 13 14 15 16
18 19 20 21 22 23 24
26 27 28 29 30 31 32
17
25
9
1 2 3 4 A B 5 6 7 8
CO NSOL E
MGM T
COMPACTFL ASH
MSM-1XL60016
MST
REN
V
SYS
ERR
CO NSOL E
MGM T
COMPACTFL ASH
MSM-1XL60016
MST
REN
V
SYS
ERR
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
G60X61010
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
DS
FWE-WK134.225.255.5
CORE-WK
DMZ-WK
SLB-WK
DIST-LYL
DIST-SSE DIST-LON
DIS
T-W
KH
3808lpine
1
2
3
4
5
6
7
8
PSU45012
SER VIC E
DC ON DC ON
WHEN INSTALLED IN 3808 THIS WAY UP
WHEN INSTALLED IN 3804 THIS WAY UP A
V Hz A100 - 120200 - 240
5060
136
613
6050
200 - 240100 - 120
Hz V
SLIDE TO REMOVE
PSU
PSU45012
SER VIC E
DC ON DC ON
WHEN INSTALLED IN 3808 THIS WAY UP
WHEN INSTALLED IN 3804 THIS WAY UP A
V Hz A100 - 120200 - 240
5060
136
613
6050
200 - 240100 - 120
Hz V
SLIDE TO REMOVE
PSU
DIAGSTATUS
AB
PSU CONSOLE MODEM MGMT
PCMCIALINK\ACTIVE
SMM45014
i
GM-4X45112
i
STATUS
1000 B ASE -X
4321
GREENAMBER
FLASHING ORANGE
- ACTIVITY- LINK OK
- DISABLED1 2 3 4
GM-4X45112
i
STATUS
1000 B ASE -X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK- DISABLED1 2 3 4
GM-4X45112
i
STATUS
1000 B ASE -X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK- DISABLED1 2 3 4
FM-32T45210
i
STATUS
GREENAMBER
FLASHING ORANGE
- ACTIVITY- L INK OK
- DISABLED
10/100 B ASE-T XMD I-X
4
20
1
17
8
24
5
21
12
28
9
25
16
32
13
29
1 2 3 4 5 6 7 810 11 12 13 14 15 16
18 19 20 21 22 23 24
26 27 28 29 30 31 32
17
25
9
GM-4T45113
i
STATUS
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED
100/1000 B ASE -TX
1
MD I-X
2 3 4
1000 BASE-TX
1 2 3 4
1 2 3 4
GM-16X45121
31 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
GREENAMBER
FLASHING ORANGE
- ACTIVITY- L INK OK
- DISABLED
1 2 3 45 6 7 8
9 10 11 12
13 14 15 16STATUS
1000 B ASE -XSFP
GM-16T45122
31 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- L INK OK- DISABLED
1 2 3 4
5 6 7 89 10 11 12
13 14 15 16STATUS10/100/1000 BA SE-T
GM-16T45122
31 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- L INK OK
- DISABLED
1 2 3 4
5 6 7 8
9 10 11 1213 14 15 16STATUS
10/100/1000 BA SE-T
3808lpine
1
2
3
4
5
6
7
8
PSU45012
SER VIC E
DC ON DC ON
WHEN INSTALLED IN 3808 THIS WAY UP
WHEN INSTALLED IN 3804 THIS WAY UP A
V Hz A100 - 120200 - 240
5060
136
613
6050
200 - 240100 - 120
Hz V
SLIDE TO REMOVE
PSU
PSU45012
SER VIC E
DC ON DC ON
WHEN INSTALLED IN 3808 THIS WAY UP
WHEN INSTALLED IN 3804 THIS WAY UP A
V Hz A100 - 120200 - 240
5060
136
613
6050
200 - 240100 - 120
Hz V
SLIDE TO REMOVE
PSU
DIAGSTATUS
AB
PSU CONSOLE MODEM MGMT
PCMCIALINK\ACTIVE
SMM45014
i
GM-4X45112
i
STATUS
1000 BA SE- X
4321
GREENAMBER
FLASHING ORANGE
- ACTIVITY- LINK OK
- DISABLED1 2 3 4
GM-4X45112
i
STATUS
1000 BA SE- X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK- DISABLED1 2 3 4
GM-4X45112
i
STATUS
1000 BA SE- X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK- DISABLED1 2 3 4
GM-4X45112
i
STATUS
1000 BA SE- X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
GM-4X45112
i
STATUS
1000 BA SE- X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK
- DISABLED1 2 3 4
FM-32T45210
i
STATUS
GREENAMBER
FLASHING ORANGE
- ACTIVITY- L INK OK
- DISABLED
10/100 B ASE-T XMD I-X
4
20
1
17
8
24
5
21
12
28
9
25
16
32
13
29
1 2 3 4 5 6 7 810 11 12 13 14 15 16
18 19 20 21 22 23 24
26 27 28 29 30 31 32
17
25
9
3808lpine
1
2
3
4
5
6
7
8
PSU45012
SER VIC E
DC ON DC ON
WHEN INSTALLED IN 3808 THIS WAY UP
WHEN INSTALLED IN 3804 THIS WAY UP A
V Hz A100 - 120200 - 240
5060
136
613
6050
200 - 240100 - 120
Hz V
SLIDE TO REMOVE
PSU
PSU45012
SER VIC E
DC ON DC ON
WHEN INSTALLED IN 3808 THIS WAY UP
WHEN INSTALLED IN 3804 THIS WAY UP A
V Hz A100 - 120200 - 240
5060
136
613
6050
200 - 240100 - 120
Hz V
SLIDE TO REMOVE
PSU
DIAGSTATUS
AB
PSU CONSOLE MODEM MGMT
PCMCIALINK\ACTIVE
SMM45014
i
GM-4X45112
i
STATUS
1000 BA SE- X
4321
GREENAMBER
FLASHING ORANGE
- ACTIVITY- LINK OK
- DISABLED1 2 3 4
GM-4X45112
i
STATUS
1000 BA SE- X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVITY
- LINK OK- DISABLED1 2 3 4
GM-16X45121
31 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
GREENAMBER
FLASHING ORANGE
- ACTIVITY- L INK OK
- DISABLED
1 2 3 45 6 7 8
9 10 11 1213 14 15 16STATUS
1000 B ASE -XSFP
FWE-EG134.225.255.6
CORE-EG
DMZ-EG
SLB-EG
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
CONSOL E
49 50
MGMT
PORT 49
PORT 50
Extreme Networks Summit48siR
1 2 3 4 A B 5 6 7 8
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
CONSO LE
MGM T
COMPACTFL ASH
MSM-1XL60016
MST
REN
V
SYS
ERR
CONSO LE
MGM T
COMPACTFL ASH
MSM-1XL60016
MST
REN
V
SYS
ERR
G60X61010
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
DS
G60X61010
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
DS
PCMCIA
CONSOLE
MODEM
STATUS
ALARM
PWR 2
TEMP
FW
SESSION
SHAPEPCMCIA
VPN
HA
FA N
PWR 1
UNT RUS T1
1 23 4
10/100 MGT HA-1 HA-2
TOP = LIN K/ACTIVITYBOTTOM = 10/100 MbpsNE TSCRE EN 500
ISG 2000FE 8
1 2 3 4 5 6 7 8
PW R A LA RM TE M P S TA TU S HA
FA N M O D1 M O D2 M O D 3 FL A SH
COMPACT FLASHCONSOLE MODEM MGT
10/100
TX/RX LIN K
1 3
2 4
N E T S C R E E N
ISG 2000 LOCK
UNL OCK
ISG 2000FE 8
1 2 3 4 5 6 7 81
LINK
TX/RX
2
LINK
TX /RX
ISG 2000GB2
1
LINK
TX/RX
2
LINK
TX /RX
ISG 2000GB2
ISG 2000FE8
1 2 3 4 5 6 7 8
P WR AL AR M TE M P ST AT US H A
FA N M O D1 M OD 2 M O D 3 FL AS H
COMPACT FLASHCONSOLE MODEM MGT
10/100
TX/ RX LIN K
1 3
2 4
N E T S C R E E N
ISG 2000 LOCK
UNL OCK
ISG 2000FE8
1 2 3 4 5 6 7 81
LINK
TX/RX
2
LINK
TX/RX
ISG 2000GB2
1
LINK
TX/RX
2
LINK
TX/RX
ISG 2000GB2
FWA-WK
FW-FMD
HA
FLASH
ST ATUS-1
SESSION
POW ER
AL ARM
CO NSO LE M ODE M COMPACT FL ASH 1
10/100
TX /RX LINK2
10/100
TX/RX LINK3
10/100
TX/ RX LIN K4
10/100
TX /RX LINK
N e t S c r e e n – 5 0
7To put your footer here go to View > Header and Footer
Server connectivity upgrade
• Introduction of 10Gbit Ethernet into the core• Two new (large) switches to be installed into ITS
machine rooms– Each switch will have 10GBit/s to each core router (20Gbit/s)– Two switches connected to each other at 20Gbit/s– Each switch configured to connect up to 240 ports at 1Gbit/s– Switches configured as redundant pair for routing server
VLANs• Two small switches will provide secondary
connections– To be used by important systems only (Exchange, etc)
8To put your footer here go to View > Header and Footer
1 2 3 4 A B 5 6 7 8
CONSOLE
MGM T
COMPACTFLASH
MSM-1XL60016
MS
TRE
NV
SYS
ERR
CONSOLE
MGMT
COM PACTFLASH
MSM-1XL60016
MS
TRE
NV
SYS
ERR
10G6X61050
DS
1
2
3
4
5
6
1
2
3
4
5
6
G60X61010
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
DS
G60X61010
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
DS
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
1
2
3
4
7
8
9
10
6B
5A
Dia
gS
tat
G4 8T a 41 5 15
2 51 2 62 2 73 2 84 295 306 317 328 239 3410 3511 361 2 371 3 3 81 4 3 915 4 016 4117 4218 4319 4420 4521 4622 4723 4824
ab
Dia
gS
tat
G4 8T a 41 5 15
2 51 2 62 2 73 2 84 295 306 317 328 239 3410 3511 361 2 371 3 3 81 4 3 915 4 016 4117 4218 4319 4420 4521 4622 4723 4824
ab
Dia
gS
tat
G4 8T a 41 5 15
2 51 2 62 2 73 2 84 295 306 317 328 239 3410 3511 361 2 371 3 3 81 4 3 915 4 016 4117 4218 4319 4420 4521 4622 4723 4824
ab
Dia
gSt
at
G4 8T a 41 5 15
2 51 2 62 2 73 2 84 295 306 317 328 239 3410 3511 361 2 371 3 3 81 4 3 915 4 016 4117 4218 4319 4420 4521 4622 4723 4824
ab MSM-G8X 41211
ERR
ENV
1000BASE-X
1
5 8
4
MSTR/DIAG
SYS/STATCOMPACT F LASH
ACONSOLE
D RMGMT
4 83 72 61 5
MSM-G8X 41211
ERR
ENV
1000BASE-X
1
5 8
4
MSTR/DIAG
SYS/STATCOMPACT F LASH
ACONSOLE
D RMGMT
4 83 72 61 5
Dia
gS
tat
G4 8T a 41 5 15
2 51 2 62 2 73 2 84 295 306 317 328 239 3410 3511 361 2 371 3 3 81 4 3 915 4 016 4117 4218 4319 4420 4521 4622 4723 4824
ab
Diag
Stat
10GBASE-X1 32 4
10G4X 416 11
Diag
Stat
10GBASE-X1 32 4
10G4X 416 11
1 2 3 4 A B 5 6 7 8
CONSOLE
MGMT
COMPACTFLASH
MSM-1XL60016
MS
TREN
V
SYS
ERR
CONSOLE
MGMT
COMPACTFLASH
MSM-1XL60016
MS
TREN
V
SYS
ERR
10G6X61050
DS
1
2
3
4
5
6
1
2
3
4
5
6
G60X61010
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
DS
G60X61010
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
DS
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
G60T61030
DS
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
10
40
11
41
12
42
13
43
14
44
15
45
16
46
17
47
18
48
19
49
20
50
21
51
22
52
23
53
24
54
25
55
26
56
27
57
28
58
29
59
30
60
30 60
311
1
2
3
4
7
8
9
10
6B
5A
Dia
gS
tat
G48 Ta 41 5 1 5
251 262 273 284 295 306 3 17 3 28 239 3410 3511 3612 3713 3814 3915 4016 411 7 4 21 8 4319 4 42 0 4 521 4622 4723 4824
ab
Dia
gS
tat
G48 Ta 41 5 1 5
251 262 273 284 295 306 3 17 3 28 239 3410 3511 3612 3713 3814 3915 4016 411 7 4 21 8 4319 4 42 0 4 521 4622 4723 4824
ab
Dia
gS
tat
G48 Ta 41 5 1 5
251 262 273 284 295 306 3 17 3 28 239 3410 3511 3612 3713 3814 3915 4016 411 7 4 21 8 4319 4 42 0 4 521 4622 4723 4824
ab
Dia
gSt
at
G48 Ta 41 5 1 5
251 262 273 284 295 306 3 17 3 28 239 3410 3511 3612 3713 3814 3915 4016 411 7 4 21 8 4319 4 42 0 4 521 4622 4723 4824
ab MSM-G8X 41211
ERR
ENV
1000BASE-X
1
5 8
4
MSTR/DIAG
SYS/STATCOMPACT FLASH
ACONSOL E
D RMGM T
4 83 72 61 5
MSM-G8X 41211
ERR
ENV
1000BASE-X
1
5 8
4
MSTR/DIAG
SYS/STATCOMPACT FLASH
ACONSOL E
D RMGM T
4 83 72 61 5
Dia
gS
tat
G48 Ta 41 5 1 5
251 262 273 284 295 306 3 17 3 28 239 3410 3511 3612 3713 3814 3915 4016 411 7 4 21 8 4319 4 42 0 4 521 4622 4723 4824
ab
Diag
Stat
10GBASE-X1 32 4
10G4X 41611
Diag
Stat
10GBASE-X1 32 4
10G4X 41611
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
CONSOL E
49 50
MGMT
PORT 49
PORT 50
Extreme Networks Summit48siR
3804lpine
1
2
3
4
DIAG
ST ATUS
AB
PSU CONSOL E MODEM MGM T
PCM CIALINK\ACT IVE
SMM45014
i
GM-4X45112
i
ST AT US
1000 BASE-X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVIT Y
- LINK OK
- DI SABL ED1 2 3 4
GM-4X45112
i
ST AT US
1000 BASE-X
4321
GREEN
AMBER
FLASHING ORANGE
- ACTIVIT Y
- LINK OK
- DI SABL ED1 2 3 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
CONSOLE
49 50
MGMT
PORT 49
PORT 50
Extreme Networks Summit48s iR
3804lpine
1
2
3
4
DI AG
ST ATUS
A
B
PSU CO NSOL E MODEM MGMT
PCMCIALINK\ACT IVE
SMM45014
i
GM-4X45112
i
ST AT US
10 00 BASE-X
4321
GREEN
AM BER
FLASHI NG ORANGE
- ACTIVIT Y
- LINK OK
- DI SABLED1 2 3 4
GM-4X45112
i
ST AT US
10 00 BASE-X
4321
GREEN
AM BER
FLASHI NG ORANGE
- ACTIVIT Y
- LINK OK
- DI SABLED1 2 3 4
CONSOLE
FAN
PSU-i
PSU-E
St ackMGMT
SolidBlin kin g Extreme Networks Summit 400-48tR R
1 5
2 6
3 7
4 8
1x 2x 3x 4x 5 76 8 9 11 13 1510 12 14 161 32 4 25 27 29 3126 28 30 3217 19 21 2318 20 22 24 41 43 45 4742 44 46 4833 35 37 3934 36 38 40
Extreme NetworksSummit EPS-T
CONSOL E
FAN
PSU- i
PSU- E
Sta ckMGMT
So li dBlinking Extreme Networks Summit 400-48tR R
1 5
2 6
3 7
4 8
1x 2x 3x 4x 5 76 8 9 11 13 1510 12 14 161 32 4 25 27 29 3126 28 30 3217 19 21 2318 20 22 24 41 43 45 4742 44 46 4833 35 37 3934 36 38 40
Extreme NetworksSummit EPS-T
FWE-WK FWE-EG
DMZ-WK
SLB-WK SRV-WK SRV-EG
SRV-SEC-WK SRV-SEC-EG
SLB-WK
DMZ-EG
9To put your footer here go to View > Header and Footer
Server connectivity upgrade
10To put your footer here go to View > Header and Footer
Guest / wireless network changes
• Deployment of JANET Roaming / Eduroam– Web-based redirect no longer permitted to be
advertised as eduroam name– New wireless network across campus to sit alongside
existing service• SSID ‘eduroam’• Requires 802.1x and WPA / WPA2 encryption• Set up and forget – works everywhere that has
Eduroam
11To put your footer here go to View > Header and Footer
Guest / wireless network changes
• Changes to existing ‘rdg.ac.uk’ service– Will move outside firewall
• But retain protection from Internet hosts• Same set of base services as for JANET Roaming• Additional resilience through second BlueSocket device
– Web-based login will accept eduroam / JANET Roaming credentials
– Proposed service changes Summer 2008:• Users will no longer be able to sign on with plain
username– Must use ‘[email protected]’ instead
• Native CIFS access will be turned off – shares still accessible through NetDrive service (WebDAV gateway)
12To put your footer here go to View > Header and Footer
Guest / wireless network changes
• New IP address ranges:– 134.225.24.0 – 134.225.27.255 for JANET Roaming
service– 134.225.28.0 – 134.225.31.255 for plug-in and
‘rdg.ac.uk’ service• Old address ranges to be removed by
September 2007:– 134.225.8.0 – 134.225.15.255
13To put your footer here go to View > Header and Footer
Subnet changes• Psychology to complete move to .114 subnet• Soil and Plant Science to move to own subnets• Systems Engineering to vacate .4 and .56
subnets• Student subnets in Careers, Chaplaincy and
RUSU to be separated
14To put your footer here go to View > Header and Footer
DNS / DHCP infrastructure• Currently two central servers
– Sun hardware– Open source software– A bunch of in-house scripts to generate DNS zones– More in-house scripts to generate DHCP configuration– Painful to manage– Relatively slow turn-around for IP address allocation
15To put your footer here go to View > Header and Footer
DNS / DHCP infrastructure• New Infoblox 1550 appliances (HA pair)
– Take over as master DNS database– Replace Sun boxes for DHCP– GUI for managing IP address and hostname allocation– Should give faster turn-around on IP allocations– Possibility of delegation (at least read-only) to IT
supporters• Expansion of DNS topology
– Existing Sun boxes become dedicated DNS cache servers– Addition of DNS servers into DMZ for best practise– Possible additional IT Services managed DNS secondary
server at off-site co-location facility