DISTRIBUTION NETWORK SYSTEMS
Unit of boxes and cabinets especially designed
for protection and measurement in distribution
networks of electricity, water or gas.
They are divided into three ranges depending
on the application.
CGP Range
Box designed to be installed in the circuit break
protection of the general electric lines. It is therefore
suitable for the fixing of fuse bases.
PLANYLECT Range
Cabinets designed as enclosure for common
electrical material, but especially for electric,
water and gas meters.
PROMECO Range
The components of this range have been designed
to be used in electrical meter centers and to be
installed in the common area of a housing building.
METERING CENTRES
System of isolating modulesand panels accordingto the power supply company’snorms in every country.
GENERAL PROTECTIONAND METERING BOX
Unit for protection and meteringof 1 or 2 mono-phaseor three-phase supplies.
GENERALPROTECTION BOX
The boxes in the CGP rangeare designed to be installedin the circuit breakprotection of the generalelectric lines.
ELECTRICAL
GAS
WATER
URBANDISTRIBUTION BOX
Cabinet designedas an enclosure for electricalmaterial in generaland especiallyfor communications.
MATERIAL QUALITIES
For the manufacture of thecomponents of the different series,high-tech insulating materials areused which give the productsdistinctive features, whosecharacteristics are the following:
HIGH IMPACT RESISTANCE
SELF–EXTINGUISABLE
DOUBLE INSULATION
CORROSION PROOF
NON-HYGROSCOPIC
EASY MECHANIZATION
QUICK AND EASY ASSEMBLY
WEATHER PROOF
LIGHT
INSULATINGBEST IN SYSTEMS FOR
DISTRIBUTION NETWORK
98
CERTIFICATIONS
DEGREE OF PROTECTIONIP43 Series CGPIP43 Series PLANYLECTIP40 System PROMECOIP54 Cabinet ADURAccording to rulingsUNE 20324, EN 60529and IEC 60529
IMPACT RESISTANCE10 Joules (IK09) CGP20 Joules (IK10) PLANYLECT5 Joules (IK08) PROMECO10 Joules (IK09) ADURAccording to rulingsUNE-EN 50102 and IEC 62262
SELF EXTINGUISHABLE960° according to rulingsUNE-EN 60695-2-1/0and IEC 60695-2-10
DOUBLE INSULATIONAccording to rulingsUNE-EN 60439-and IEC 60439-1
THERMAL CLASSB 130° Series CGP, Series PLANYLECT and ADUR.A 105° System PROMECORuling UNE 21305
EN-HD 566S1 and IEC 60085
APPROVALSAND CERTIFICATIONS
AUTOVENTILATEDAuto ventilated,protection degree IP43,impact resistance IK09.
FIXINGThese can be fixed to a wall,surface or in a niche.
BOXESBoxes designed to hold fuse-basesin the interior, to protect the connections.
LOCKTriangular head screw of 11 mm,sealable and unloosable.
REMOVABLE COVERRemovable front cover, held to the boxwith a device, which hinders the coverfrom being totally unattached.
CGP BOX RANGE
The boxes in the CGP range are designed to hold fuse-bases in the interior,to protect the main lines of power distribution (according to the norms inevery country). The fuse-bases can be installed with the separators in thebottom of the box.
CHARACTERISTICS
Double isolated box, molded in Glass-fiber reinforced Polyester.Removable front cover, held to the box with a device, which stops the coverfrom being totally unattached.Self-extinguishable.Protection IP43.Impact Resistance IK09.Installation inside or outside.Can be fixed to a wall, surface or in a niche.Halogen free.
Box + cover for In from 20 to 40 A Ref. CPV-40Box + cover for In from 63 to 100 A Ref. CPV-100Box + cover + spliced cable joint-boxfor In From 160 to 400 A Ref. CPV-400
CGP RANGE
1110
DIMENSIONS (mm)TYPE A B C
CPV-40 245 155 75
CPV-100 340 216 105
CPV-400 635 328 180
PLANYLECT RANGE
1312
ROOF TOPSPossibility to mount roof tops, being fitted directly to the upper part,maintaining the IP grade. Can be used on the PLT-00, 1, 2 models.
PLATESComplete range of base plates (plainand mechanized plates for the fittingof meters and other equipment), whichcan be fixed directly to the fasteningdevices in the cabinet.
BOTTOMBottom of the box provided with inserts for the fixingof control gear and base plates.
4 FIXING SYSTEMS4 fixing systems depending on the utilization (wall surface,built-in, post clamp and fixed to post with metal clamp).
DIFFERENT SOLUTIONSDifferent finishing solutions in the bottom partof the cabinets, depending on the necessities.
DOOR CANALA canal in the door to facilitate drainageof water once installed outside or built-in.
SPECIAL HINGESSpecial hinges to facilitatethe removal of the doors.In the PLT-00, 1 and 2 models.
DOORThe door can be closed without the need to usethe key (slide-lock) with pad locking.
3 POINT LOCKDetail of 3-point lock.
WIDE RANGE OF LOCKSWide range of locks (triangular,rectangular, with key etc...).
ANAGRAMPersonalized anagram for every cabinetapplication: electrical power, water and gas.
OPENINGThe doors can be opened >180°.
RELIEF LINESThe doors and covers have vertical bandsto hinder collocation of posters and graffiti.
MECHANIZATION POSSIBILITIESDifferent possibilities to mechanize the doordepending on the usage.
SERIE PLANYLECT
1514
Ref.Characteristics:Type of lock:Size: 317 x 430 x 190
PLT-00Closed without inspection windowsTriangular DA
PLTA-00Closed without inspection windowsTriangular
Ref.Characteristics: Type of lock:Size: 515 x 532 x 234
PLT-1CClosed without inspection windowsTriangular DA
PLTA-1CClosed without inspection windowsTriangular
PLTG-1GPClosed without inspection windowsTriangular
Ref.Characteristics: Type of lock:Size: 515 x 532 x 234
PLTG-1GTClosed without inspection windowsTriangular screw lock
Ref.Characteristics: Type of lock:Size: 515 x 532 x 234
PLT-1Closed by bottom sealing plateTriangular DA
PLTG-1TClosed by bottom sealing plateTriangular screw lock
Ref.Characteristics: Type of lock:Size: 525 x 694 x 234
PLT-2C Closed without inspection windowsTriangular DA
PLTA-2C Closed without inspection windowsTriangular
PLTG-2GP Closed without inspection windowsTriangular
Ref.Characteristics: Type of lock:Size: 525 x 694 x 234
PLTG-2GT Closed without inspection windowsTriangular screw lock
Ref.Characteristics: Type of lock:Size: 525 x 694 x 234
PLT-2A Open with inspection windowsTriangular DA
Ref.Characteristics: Type of lock:Size: 485 x 350 x 195
PLT-23 Closed without inspection windowsTriangular
PLTG-23 Closed without inspection windowsTriangular screw lock
Ref.Characteristics: Type of lock:Size: 537 x 216 x 203
PLT-0PClosed with 1 inspection windowTriangular DA
Ref.Characteristics: Type of lock:Size: 551 x 275 x 200
PLT-0 Closed with 1 inspection windowTriangular DA
POWER EMBLEM WATER EMBLEM GAS EMBLEM
Ref.Characteristics: Type of lock:Size: 317 x 430 x 190
PLT-00/1M Closed with 1 inspection windowTriangular DA
Ref.Characteristics: Type of lock:Size: 317 x 430 x 190
PLT-00/2M Closed with 2 inspection windowsTriangular DA
Ref.Characteristics: Type of lock:Size: 515 x 532 x 234
PLT-1/1M Closed with plate and 1 inspectionwindowTriangular DA
Ref.Characteristics: Type of lock:Size: 515 x 532 x 234
PLT-1/2M Closed with plate and 2 inspectionwindowsTriangular DA
Ref.Characteristics: Type of lock:Size: 515 x 532 x 234
PLT-1C/1M Closed with 1 inspection windowTriangular DA
Ref.Characteristics: Type of lock:Size: 515 x 532 x 234
PLT-1C/2M Closed with 2 inspection windowsTriangular DA
Ref.Characteristics: Type of lock:Size: 525 x 694 x 234
PLT-2C/2M Closed with 2 inspection windowsTriangular DA
Ref.Characteristics: Type of lock:Size: 525 x 694 x 234
PLT-2C/3M Closed with 3 inspection windowsTriangular DA
Ref.Characteristics: Type of lock:Size: 525 x 694 x 234
PLT-2A/2M Open with 2 inspection windowsTriangular DA
Ref.Characteristics: Type of lock:Size: 525 x 694 x 234
PLT-2A/3M Open with 3 inspection windowsTriangular DA
POWER EMBLEM WATER EMBLEM GAS EMBLEM
NOTEThe PLT-OP, PLT-00 and PLT-1 standard cabinets are supplied with PM-00 windows, which are 120 x 120 mm.The PLT-0 and PLT-2 standard cabinets are supplied with PM-12 windows, which are 160 x 120 mm.
FULL RANGEPLANYLECT
DIMENSIONS (mm)
PLANYLECT RANGE
17
PRACTICABLE PLINTH
Access from the mountable front part, fixed to the plinth with the help of twotriangular head screws of 11 mm.Equipped with metal profiles for the fixing of tubes and conductive parts.The cover is supplied with two devices, which can be used for pad-locks if needed.Made in polyester.
For PLT-1 Ref. ZPLT-1
MOUNTING PLATES
Made in polyester.
For PLT-0P Ref. PB-0PFor PLT-0 Ref. KGP-463Para PLT-00 Ref. PB-00Para PLT-1 Ref. PB1Para PLT-2 Ref. PB2
MECHANIZED PLATES FOR METERS(Does not include screws for the fixing of the meter)
Mechanized mounting plate for the fixing of electrical meters.Made in polyester.
For a 1-phase meter in PLT-0P Ref. P1M/PLT0PFor a 1-phase or 3-phase meter in PLT-0P Ref. P1MT/PLT0PFor a 1-phase meter in PLT-0 Ref. P1M/PLT0For a 1-phase or 3-phase meter in PLT-0 Ref. P1MT/PLT0For a 1-phase meter and a clock in PLT-00 Ref. P1Mr/PLT0For a 1-phase or 3-phase meter and a clock in PLT-1 Ref. P1MTr/PLT1For two 3-phase meters in PLT-1 Ref. P2T/PLT1For two 3-phase meters and clock in PLT-2 Ref. P2TR/PLT2For three 1-phase or 3-phase meters in PLT-2 Ref. P3TM/PLT2
To be fixed directly to the bottom of the cabinet.Increasing height set for mounting plate Ref. EPB
ROOFS
To be fitted on the upper part of the cabinet.Made in polyester.
For PLT-00 Ref. TV-00For PLT-1 Ref. TV-1For PLT-2 Ref. TV-2
16
FIXINGThere are 4 ways of fixing this type of cabinet depending on usage.
FIXINGPLANYLECT
Wallsurface
PLT-OP 440 225 213PLT-0 540 270 174PLT-00 — 445 205PLT-1 364 551 250PLT-2 354 711 250PLT-23 405 390 215
Wallbuilt-in
PLT-0P 525 245 130PLT-0 540 270 174PLT-00 325 485 190PLT-1 500 510 210PLT-2 510 670 210PLT-23 500 360 200
Post clamp
PLT-0P 537 241 360PLT-0 540 270 360PLT-00 317 430 285PLT-1 517 600 285PLT-2 517 760 285
Post withmetal band
PLT-0P 537 241 360PLT-0 540 270 360PLT-00 317 430 360PLT-1 517 535 360PLT-2 517 678 360
Ground/polyesterplinth
PLT-1/2 120 440 12PLT-23 100 285 10
Ground/concreteplinth
PLT-1/2 120 440 12PLT-23 100 285 10
DIMENSIONS (mm)
A 537 551 317 515 525 485B 216 275 430 532 694 350C 203 200 190 234 234 195
ACCESSORIESPLANYLECT
TYPE PLT-0P PLT-0 PLT-00 PLT-1 PLT-2 PLT-23
ASSEMBLY CLOSET E F G
DIMENSIONS (mm)
PLANYLECT RANGE
1918
ACCESSORIESPLANYLECT
INSPECTION WINDOW
Supplied with watertight gaskets.Protected from ultraviolet (UV) radiation.Made of polycarbonate.
From 120 x 120 mm Ref. PM-00From 160 x 120 mm Ref. PM-12
CABLE CHANNELS
For the protection of the cables entering the bottom of the cables.Made in polyester.
For PLT-1 y PLT-2 Ref. PC
LOCKS
The normal lock for the Planylect range cabinets is a one-point lock, except forthe PLT-0 one, which is a two-point lock.
TRIANGULAR
The normal lock for the Planylect range cabinets is a 11mm triangular one.
Triangular lock for PLT-0 and PLT-0P cabinets Ref. PTT-0Triangular lock for PLT-00, PLT-1 and PLT-2 cabinets Ref. PCT-12
Triangular key Ref. LLT
THREE POINT TRIANGULAR CLOSING SYSTEM
Allows the cover of the cabinet to be closed in three points.The supply should be fitted in the cabinet.
Triangular three-point lock for PLT-00 cabinets Ref. PCT-00/3PTriangular three-point lock for PLT-1 cabinets Ref. PCT-1/3PTriangular three-point lock for PLT-2 cabinets Ref. PCT-2/3P
TRIANGULAR SCREW LOCK
Triangular screw lock for cabinets used for Gas applications.
Triangular screw lock for PLT-00, PLT-1, PLT-2and PLT-23 cabinets Ref. PTR-12
RECTANGULAR
Rectangular screw lock for PLT-00, PLT-1 and PLT-2 Ref.: PCR-12
KEY
Locking system with DIN key lock, which offers manypossible locking combinations.
Key-lock for cabinetsPLT-00, PLT-1 and PLT-2 Ref.: PCL-12
KEY AND THREE POINT CLOSING SYSTEM
Locking system, which offers many possible locking combinations.Allows the cover of the cabinet to be closed in three points.This lock should be fitted in the box when delivered.
Key and three point closing system for PLT-00 cabinets Ref. PCL-00/3PKey and three point closing system for PLT-1 cabinets Ref. PCL-1/3PKey and three point closing system for PLT-2 cabinets Ref. PCL-2/3P
PADLOCKING
Allows locking and/or sealing by the electrical utility company.
Padlocking for PLT-0P cabinets Ref. PEC-0P
Padlocking for PLT-0 cabinets Ref. PEC-0
Padlocking for PLT-00, PLT-1,PLT-2 cabinets Ref. PEC-12
FIXING OF THE PLANYLECT CABINETS
There are 4 ways of fixing this type of cabinet depending on usage:
WALL SURFACE OR BUILT-IN
The fixing is done with the help of brackets.Made of galvanized steel.
Sets of 4 brackets for PLT-0P Ref. OFPL-0PSets of 4 brackets for PLT-0 Ref. OFPL-0Sets of 2 brackets for PLT-00 Ref. OFPL-00Sets of 4 brackets for PLT-1 and PLT-2 Ref. OFPL-12Sets of 4 brackets for PLT-23 Ref. OFPL-3
ACCESSORIESPLANYLECT
PLANYLECT RANGE
2120
POST CLAMP
Fixing with the help of a post clamp.
Set for PLT-0P Ref. FPB-0PSet for PLT-0 Ref. FPB-0Set for PLT-00 Ref. FPB-00Set for PLT-1 Ref. FPB-1Set for PLT-2 Ref. FPB-2
POST WITH METAL BAND
Fixing with the help of a metal band.
Set for PLT-0P Ref. FPF-0PSet for PLT-0 Ref. FPF-0Set for PLT-00 Ref. FPF-00Set for PLT-1 Ref. FPF-1Set for PLT-2 Ref. FPF-2
METER FIXING SCREWS
Upper brass screw Ref. TFS
Lower brass screw Ref. TFI
Set of isolating screws (1 unit upper / 2 units lower) Ref. TFC-A
CABLE GLANDS
Rings of neoprene and cones for the passing of cables or tubes.To be fitted directly on the wall of the box, closing plates andcable cutouts.
ø CABLES ø TUBES ø HOLES10-28 mm 12-25 mm 31 mm Ref. C2812-35 mm 12-32 mm 41 mm Ref. C35
ø TUBES1” Ref. C1
1 1/2” Ref. C152” Ref. C2
Tube glands for gas 1 1/4” Ref. CPT
SET OF TERMINALS(Amplified terminal)
Is made of four contacts made of electrolytic cupper 70 x 3 mm, in which thebimetallic terminals of different sections, depending on what the user needs.The exits have four derivations per phase and neutral for a cable up to 35 mm.Covered with protection against accidental contacts.Sealable for the electrical utility company.Nominal voltage 690 V.Maximum permanent power 400 A.Derivation terminal fitted on a glass-fibre reinforced polyester pedestal.
PRINCIPAL LINE DERIVATION4 Bimetallic terminalsfrom 95 mm2 4 (4 x 35 mm2) Ref. SBD-4/1952 x 4 Bimetallic terminalsfrom 95 mm2 4 (4 x 35 mm2) Ref. SBD-4/2954 Bimetallic terminalsfrom 150 mm2 4 (4 x 35 mm2) Ref. SBD-4/11502 x 4 Bimetallic terminalsfrom 150 mm2 4 (4 x 35 mm2) Ref. SBD-4/21504 Bimetallic terminalsfrom 240 mm2 4 (4 x 35 mm2) Ref. SBD-4/12404 Bimetallic terminalsfrom 240 mm2 4 (4 x 35 mm2) Ref. SBD-4/2240
BIMETALLIC TERMINALS
Are made to link and fasten aluminium and cupper cables to bars or terminalsmade of cupper.A technical solution to problems arising from in the unification of two materials.
Terminals BMT-35 for neutral Ref. BMT-35NTerminals BMT-35 for short phase Ref. BMT-35FPCTerminals BMT-35 for long phase Ref. BMT-35FPLTerminals BMT-35 with wing Ref. BMT-35A
Terminals BMD-35 double neutral Ref. BMD-35NTerminals BMD-35 double neutral with wing Ref. BMD-35NATerminals BMD-35 double phase with wing Ref. BMD-35FA
Terminals BM-50 Ref. BM-50Terminals BM-95 Ref. BM-95Terminals BM-150 Ref. BM-150Terminals BM-240 Ref. BM-240Terminals BM-50/2P Ref. BM-50/2PTerminals BM-95/2P Ref. BM-95/2PTerminals BM-150/2P Ref. BM-150/2PTerminals BM-240/2P Ref. BM-240/2PParallel terminals 150 (1+2) Ref. BP-150/1+2Parallel terminals 240 Ref. BP-240
ACCESSORIESPLANYLECT
2322
FUNCTIONAL METERING UNITModular and panel functional metering unit.
SCREWSThe universal self-fixing screws, allows the mountingplate for meters, profiles support devices etc. to befixed directly to the box.
FITTINGFitting between boxes without the needfor connection pieces horizontally nor vertically.It is not needed when fitted to a Combiesterbox either.
MECHANIZATIONEvery kind of unit is mechanized, enablingfitting without further mechanization.
FIXING OF ELEMENTSFixing of the ground terminal and the profile/s,directly to the bottom of the functional unitof the subscriber exit.
PROMECO RANGE
FUNCTIONAL EXIT UNITExits to the subscribers on the upper partof the metering central (functional exit unit).
FUNCTIONAL UNITThe modular functional unitsare equipped with moulded canalsfor individual canalisations.
SWITCHA switch that can be coupled to both sidesof the functional unit, the general bar-unit or fuses.No connection pieces are needed.
CLOSING SCREWSScrews for fast closing of the box (1/4 turn),sealable and impossible to lose.
FIXING TO A WALLDifferent systems for fixing the cabinet to a wall(on a profile or with brackets).
The components of this range
have been designed, to be used in electrical
metering centres and to be installed
in common centralisation in a building.
PROMECO RANGE
2524
EXIT UNIT
Allows the fitting of the exit terminals (to the different subscribers)and to the protection bar.Consists of:
Cover + box with opening in the lower part to fit the meter unit.Self-fixing screws of protection bar and DIN-profile.
For 1 DIN profile PR-270B
For 2 DIN profiles PR-390B
METERING UNIT
Allows the fitting of metering equipment.Consists of:
Cover + box with opening in the lower and upper part to fit the meterand exit unit.Support plate for metering equipment with meter fixing screws.Self-fixing screws for the support plate.Cable stopper.
For 4 single-phase meters PR-270C
For 3 three-or single-phasemeters
PR-390C
METERING UNIT PANEL
Allows the fitting of double insulated metering equipment.With opening in the lower and upper part to fit the meter and exit unit.Consists of:
Panel.Support plate for metering equipment with meter fixing screws.Cable stopper.
For 4 single-phase meters PRP-280C
For 3 three-or single-phasemeters
PRP-400C
GENERAL BAR AND FUSE UNIT
Allows the fixing of the general bar-units and the fuses for everyindividual derivation.Consists of:
Cover + box with opening in the upper and side parts to fit the meter unit and connections.Bar supports.Self-fixing screws for support fixing.
For D02 fuse PR-270F
For D02 and D03 fuses PR-390F
270 x 626 x 180 390 x 626 x 200 280 x 626 x 40 400 x 626 x 40FUNCTIONAL UNITS. Measures: height x width x depth (mm)
FULL RANGEPROMECO
PROMECO RANGE
2726
METER FIXING SCREW
Upper brass screw Ref. TFS
Lower brass screw Ref. TFI
Set of insulating screws(1 unit upper/2 units lower) Ref. TFC-A
END PLATE
End Plates for the side openings of the bar unit.One of the sides in centralization is usually closed, because the bar boxes areinternally connected and does therefore not need a plate. This plate is neitherneeded when the net connection is made in another type of equipment.
For box PR-270F Ref. TC-270
For box PR-390F Ref. TC-390
FIXING SYSTEMS
WALL BRACKETS
To fix the centralization directly to the wall.Made of galvanized steel.
Wall brackets Ref. OFPR
BOX CONNECTION PIECE
To connect boxes.
Connection pieces Ref. UCP
SLOTTED RAIL “C”
To fix the centralisation or panel directly to the wall.Length 2 m.
Slotted rail Ref. CRPR
CLOSING SCREWS
Screws for fast closing of the box (1/4 turn), sealableand impossible to lose.
Set of four closing screws Ref. TCP
To facilitate sealing when low covers are surrounded by high ones.
Double seal closing screw Ref. TCDP
CANAL FOR PANEL
To separate the different derivations.Length 2,5 m.
Canal from PRP Ref. CPR
LABEL HOLDER
To identify the equipment and the corresponding subscriber.
Label holder Ref. PEC
SELF-FIXING UNIVERSAL METALLIC SCREWS
Allows the direct fixing of plates, canals and bar-holders.
Self-fixing screw Ref. TAPR
ACCESSORIESPROMECO
ACCESSORIESPROMECO
2928
BAR-HOLDERS
Allows the fixing of the bars and bar units.
Bar-holders Ref. SBPR
FUNCTIONAL UNIT OF MAIN SWITCH
This unit can be fitted into different boxes of the Combiester range, type E2727,E2736 and E3636 with switch disconnector in the Dumeco range, type S-22c/4of 160 A or S-22d/4 of 250 A.The fitting of this unit is done directly to the side of the bar-unit of the cen-tralization.
CONNECTION SET
A group of connections to unite the functional part of the bar unit with thefunctional unit of the main switch.Made in copper.
Connection set Ref. CONEXIONES
INSPECTION WINDOW
Allows the accessibility to the box, maintaining the grade of protection.Made of transparent Polycarbonate.
For a multifunctional meter (integrated) Ref. TR-24
VENTILATION DEVICE
To obtain air-circulation inside the cabinet.Made of Polyamide.
Standard size in RAL 7030 Ref. DV
CABLE BOX
Are used for the entering of cables or to facilitatethe expansion of cables.Made of Polyester.Colour RAL 7030.
Closed box (without holes) for opening 3 Ref. E403Box with 1 cable-gland ø max. 1 x 60 opening 3 Ref. E403/160Box with 2 cable-glands ø max. 2 x 60 opening 3 Ref. E403/260Closed box (without holes) for opening 4 Ref. E404Box with 1 cable-gland ø max. 1 x 60 opening 4 Ref. E404/160Box with 2 cable-glands ø max. 2 x 60 opening 4 Ref. E404/260Box with 3 cable-glands ø max. 3 x 60 opening 4 Ref. E404/360Box with 1 cable-gland ø max. 1 x 80 opening 4 Ref. E404/180Box with 2 cable-glands ø max. 2 x 80 opening 4 Ref. E404/280
CABLE DIVISION BOX
Are used for the entering of cables or to facilitate the expansion of cables.Supplied with two Neoprene rings which can be cut to ø 41, 46, 55 and 60 mm.Made of Polyester.Colour RAL 7030.
Box with 2 rings ø 2 x 60 opening 3 Ref. E4290
CABLE GLANDS
Neoprene rings and cones for cables, to be fitted directly to the cabinet wall orthe cable-boxes and closing plates cut to the ø of the cable.
Ø CABLE Ø TUBE Ø HOLE5-18 mm 12-16 mm 22 mm Ref. C1810-28 mm 12-25 mm 31 mm Ref. C2812-35 mm 12-32 mm 41 mm Ref. C3530-58 mm 32-50 mm 62 mm Ref. C5810-28 mm 12-25 mm 35 mm Ref. CP-1
4 (10-28) mm 4 (12-25) mm 90 mm Ref. D240/410-60 mm 10-60 mm 75 mm Ref. D6012-80 mm 12-80 mm 95 mm Ref. D80
ACCESSORIESPROMECO
NOMINAL AMP DUMECO COMBIESTER BOX160 A S-22c/4 K-433160 A S-22c/4 K-434160 A S-22c/4 K-444
250 A S-22d/4 K-434250 A S-22d/4 K-444
PROMECO RANGE
ACCESSORIESPROMECO
CABINET FOR URBANDISTRIBUTION
3130
STANDARD LOCK(TELEFONICA OF SPAIN)Triangular lock with padlocking.Other locks can be ordered.
PERSONALISATIONPossibility to personalize “logo” on the door,according to need and usage.
POSSIBILITY TO MECHANIZEDifferent possibilities to mechanize the door,for different solutions.
INSPECTION COVERPlinth with inspection cover. The cover is opened from the insideof the cabinet.
EASY TO UNASSEMBLEIt is easy to unassemble the door,without any tools.
OPENINGSThe cabinet door can be opened 270°.
LOWER PART OF CABINETDiaphragm for the entering and exitingof cables with the help of cable glands.
FIXING SYSTEMThree fixing systems for this cabinet, accordingto need and/or usage. (Surface, wall surfaceand built-in).
GASKET MADE OF NEOPRENEWatertightness for the protection of the cabinet.
BACKBack supplied with inserts forthe fixing of control gear and baseplates.
VENTILATIONVentilation devices (2 units) for naturalconvection.
BASE PLATEBase plate according to what is neededin polyester, metal or wood.
RELIEF LINESThe door in this cabinet has relief lines to makeit more difficult to put posters and graffition the door.
METERING CENTRES
Enclosure used: The PROMECO range.Nominal Voltage: 400 V.Nominal Current: 250 A.Range of isolated modules and panels for metering centres according to the norms in every country.To be used in all electricity supply and mainly for multi-household buildings.
GENERAL PROTECTION BOX
Enclosure used.CGP and PLANYLECT range.Nominal tension 440 V.The boxes in the CGP range have a very specific application, can be delivered with the fuses andneutral and earth terminals fitted in the interior. The quantity and placement of the accessoriesfor the exits depends on the type of product and the cables used in every case.The fuse-bases can be installed with bimetallic terminals, which permit a direct connectionwith cupper or aluminium cables. It is possible to make the entrances and exits in the upperor lower part.
THE STANDARD FITTING TYPES ARE:
In 80 A with cylindrical bases 58 x 23.In 160 A with bases NH size 00.In 160 A with bases NH size 0.In 250 A with bases NH size 1.In 400 A with bases NH size 2.In 630 A with bases NH size 3.
This equipment will comply with the norms in every country.
GENERAL PROTECTION AND METERING BOX
Enclosure used: PLANYLECT range.Nominal Voltage: 440 V.Nominal Current: 40, 80 and 100 A.Set for the protection and metering of1-phase or 3-phase electrical supplies.These equipments will comply withthe norms in every country.
The PLANYLECT enclosures are designedto contain meters for the supply ofwater and gas as well.
APPLICATIONS DISTRIBUTION NETSYSTEMS
3332
CABINET FOR URBAN DISTRIBUTION
Cabinet designed as enclosure for general electrical material and especiallyfor communications.
CHARACTERISTICS
Cabinet with double insulation in moulded fibreglass reinforced polyester.Self-extinguishable.IP54 protection degree.IK09 Impact resistance.In- or outside installation.Surface, wall-surface or built-in fixing.Halogen free.
Cabinet and plinth (without base plate) Ref.: ADUR
DIMENSIONS (mm)A A1 A2 B B1 B2 C C1 C2 D H
813 680 133 537,5 528 487 180 150 180 599,4 180
DISTRIBUTION NETSYSTEMS
35
FIRST CHARACTERISTIC NUMERALProtection of people against access to hazardous parts (see additionalletter) and protection against solid foreign objects.
SECOND CHARACTERISTIC NUMERALProtection against harmful intake of water.
ADDITIONAL LETTER
If the actual protection against access to hazardous parts is higher thanthat indicated by the first characteristic numeral.
SUPPLEMENTARY LETTERS
To provide ulterior information on the material.
DEGREES OF PROTECTIONACCORDING TO UNE 20324 IEC-EN 60529
SOLIDFOREIGNOBJECTS
ACCESS TOHAZARDOUS
PARTS
Non-protected.
Protected against solid foreign objects of50 mm Ø and larger (i.e. the back of thehand).
Protected against solid foreign objects of12.5 mm Ø and larger (i.e. with a finger).
Protected against solid foreign objects of2.5 mm Ø and larger (i.e. access to haz-ardous parts with a tool).
Protected against solid foreign objects of1.0 mm Ø and larger (i.e. access to haz-ardous parts with a wire).
Dust intake is not totally prevented, butdust shall not penetrate in such a quantityto interfere with satisfactory operation ofthe apparatus or to impair safety.
Dust-tight. No dust-intake.
Non-protected.
Protected against vertically fallingwater drops
Protected against vertically fallingwater drops when enclosure is tiltedup to 15°.
Water sprayed at an angle up to 60°on either side of the vertical shallhave no harmful effects.
Water splashed against the enclo-sure from any direction shall have noharmful effects.
Water projected in jets against theenclosure from any direction shallhave no harmful effects.
Protected against powerful waterjets.
Protected against the effects of tem-porary immersion of water.
Protected against the effect of con-tinuous immersion of water
LETTER LETTERSIGNIFICANCE SIGNIFICANCE
Protected against access with the back of the hand. Theaccess probe, sphere of 50 mm Ø shall have adequateclearance from hazardous parts.
Protected against access with a finger. The jointed testfinger of 12 mm Ø, 80 mm length shall have adequateclearance from hazardous parts.
Protected against access with a tool. The access probeof 2.5 mm Ø, 100 mm length shall have adequateclearance from hazardous parts.
Protected against access with a wire. The access probeof 1.0 mm Ø, 100 mm length shall have adequate clea-rance from hazardous parts.
High-voltage apparatus.
Tested for harmful effects due to water intake when themovable parts of the equipment (e.g. the rotor of therotating machine) are in motion.
Tested for harmful effects due to water intake when themovable parts of the equipment (e.g. the rotor of therotating machine) are stationary.
Suitable for use under specified weather conditions andprovided with additional protective features or processes.
TEST
DISTRIBUTION NETSYSTEMS
3736
AGRICULTURE
CHEMICAL INDUSTRY
CONSTRUCTION SITESAND SHIPYARDS
SPORTS COMPLEXESAND OTHER PLACES OFPUBLIC ENTERTAINMENT,TV AND FILM STUDIOS
FOOD INDUSTRY
HEAVY INDUSTRY
LIGHT INDUSTRY
INSTALLATIONSFOR EDP CENTRES
PORTS
AIRPORTS
WATER TREATMENTPLANTS
Mobile or portable equipment or appliancesused or stored in sheltered premises.
Indoors in premises for storage and mainte-nance purposes where connections are notexposed to the risk of immersion or chemi-cals.
Covered construction sites sheltered againstweathering though exposed to splashingwater.
In sheltered premises protected against theweather, though exposed to splashing, with-out high-connected loads.
In sheltered locations, in indoor premisesserving for storage and maintenance.
In sheltered storehouses, workshops formaintenance, minor assembly and moulding.
Locations without high humidity or ambientpollution serving for assembly, moulding,maintenance and storage.
Electrical connections executed above floorlevel.
In sheltered locations such as docks, repairshops, offices etc.
In sheltered locations, hangars, repair shops,storehouses.
Indoor use in repair shops, etc.
Outdoor installation of pumping, ventilation,drying equipment.
On premises without risk of explosions butwhere the connections are exposed to chemi-cals and subject to possible immersion.
In outdoor construction sites where the con-nections are left on humid ground exposed tofreezing, dust and weathering.
Outdoor systems exposed to rain, snow, mud,freezing and other critical weather condi-tions, where high load for lighting installa-tions, TV or audio is expected.
In locations subject to washing by hosingdown and where connections are subject toheavy duty.
In rolling mills, foundries, blast furnaces, etc.,where the connections are exposed to dust,metal swarf, coolants and are subject tovibrations and impact.
On premises subject to cleaning by means ofchemical solvents. Also where heavy loadsrequire high safety in connections.
Electrical connections executed under raisedfloors with risk of immersion. Where heavyloads require high safety in connections.
Quays, docks, piers, etc. Where there is risk ofhigh waves and partial flooding.
Outdoors for the connection between mobileor portable appliances and aircraft
In all locations with risk of flooding and foroutdoor use with pumps, aeration and venti-lation systems.
FIELD OF USE IP43/44 IP55/67
GUIDELINE FOR THE USE OF INDEX PROTECTION DEGREES PLASTIC MATERIALS
Plastic materials are used for many applications. Finished products are obtained by using heating processes.They have a molecular structure (made) of long chains of polymers created by the interaction of severalmolecules (monomers) or pair of molecules.Distinction between thermoplastics and thermo sets has to be made.
THERMOPLATICS
Its transformation is carried out by hot mould injection. The obtained pieces of thermoplastic, can be mouldeda number of times. Most thermoplastics are soluble in normal organic solvents.
THERMOSETS
Its transformation is carried out by hot mould compression. Finished products cannot be remoulded andthey are insoluble, due to the particular molecular structure. This type of plastic cannot be hot welded andis practically insoluble in most solvents found on the market.In some cases, it is possible to use specific solvents.
PLASTICS ADVANTAGES
Double insulation gives perfect safety against direct and indirect contacts.Frame does not need earthing.Unlike metal, plastic does not rust.Enclosures are homogeneous, no maintenance is required.Because of its lightweight plastic enclosures can be easily machined, handled and installed.
MECHANICALImpact strength ISO 179 KJ/m2 55 No rupture 40 40
Notched impact strength ISO 179 KJ/m2 55 30-50 15 25
Flexural strength ISO 178 MPa 150 No rupture No rupture No rupture
Tensile strength ISO 3268 MPa 50-60 65-70 37 60
ELECTRICALTracking resistance IEC 112 V/50dr KC600 KC200 KC175 KC600
Surface resistivity IEC 93 12 15 > 12 12
Special resistivity IEC 93 Ω.cm > 1012 > 1016 > 1014 > 1012
Dielectric strength IEC 243 kV/mm 18 35 16 34
PHYSICALDeflection temperature ISO 75/A °C > 250 135 95 60
Vicat softening point ISO 306/B50 °C 145-150 109 210-220
Temperature resistance Continuous °C –50 a + 150 –50 a + 130 –50 a +100 –40 a + 100
Tropicalization and resistanceto mold and fungus growth No degradation No degradation No degradation No degradation
Water absorption ISO 62/1 96h mg 45 10 7 320
Density ISO R1183 Kg/dm3 1,75 1,2 1,1 1,14
FLAME RESISTANCELimit oxygen index ISO 4589 %O2 26 24,3 27,5 23
Flammability UL 94 3 mm 94HB 94V2 94V1 94V2
Hot wire resistance IEC 695 2-1 °C 960 850 960 650
Toxicity of fumes ISO 04615 %CI Halogen-free Halogen-free Halogen-free Halogen-free
PROPERTIES NORM UNIT POLYESTER POLYCARBONATE POLYPHENYLENE POLYAMIDE
PLASTICS TECHNICAL DATA
38
COMPABILITY OF PLASTIC MATERIALS WITH CHEMICAL COMPOUNDS
Acetic acid 10% R R RAcetic acid 50% L L RAcetone R U UAluminium chloride L R RAluminium sulphate L R RAluminium hydroxide 10% U U UAmmonia U U LAniline U U UAmyl acetate – U LAmyl alcohol – L LAntifreeze – L RAqua regia – L UBenzene R U LBenzoic acid L U LBoric acid L U LBrake fluid – L LBromine – U UButyl acetate – U LButyl alcohol R R RButyl ether – U LButilic acid L U LCalcium chloride R R RCalcium hydroxide U – LCalcium nitrate L R RCarbon dioxide L – RCarbon disulphide R U LCarbon monoxide L – LCarbon tetrachloride R U LChlorine L L LChlorobenzene R U U Chloroform R U UChromic acid 10% U R LCitric acid 5% R R RClorox – R LCopper chloride L R –Copper sulphate L R LCresol U U UCrude oils L – LDiesel fuels – R RDimethyl sulfoxide U U –Dimethyl formamine U U LDioxane – U LEthyl acetate R U LEthyl alcohol R L REthyl ether R U REthyl chloride R U LEthyl dichloride R U UEthylene glycol L R REthylene oxide – R RFerric chloride L R RFormaldehyde 37% L R RFormic acid 10% R R LFreon 113 – L RFreon 22 – U LFreon TF L L LGasoline R L RHelium U – RHeptane R R RHexane – L R
CHEMICAL POLYAMIDE POLYCARBONATE POLYESTERENVIRONMENT
Hydraulic fluid R L RHydrazine U U –Hydrobromic acid L – LHydrochlorid acid 10% L L LHydrofloric acid 10% L R LHydrogen peroxide 30% – R RHydrogen sulphide L R RIsopropyl alcohol R R RJet aircraft fuels R L RKerosene R R RLacquers – R LLactic acid 10% L R RMagnesium chloride L R RMethyl alcohol R L LMethyl ethyl ketone R U LMethylene chloride R U UMineral oils L R RNaphta – R RNitric acid 10% L R LNitrobenzene L U LOleic acid L R ROleum U – UOxalic acid 10% L R ROxygen L R ROzone – U LPerchloroethylene R – UPetroleum ether – R RPhenol L U UPhosphoric acid 25% L L LPhtalic acid L – RPotassium chloride – R RPotassium dichromate U – LPotassium hydroxide 10% L U UPotassium nitrate L R RPotassium permangate 10% U R LPyridine L U –Sodium bicarbonate U R RSodium bisulphate 10% – R RSodium carbonate 10% U R RSodium chlorate 10% – R RSodium chloride 10% L R RSodium hydroxide 10% R U LSodium hypochlorite 10% U R LSodium nitrate L U RSulphur dioxide L L RSulphuric acid L L LTartaric acid L R RTetrahydrofuran – U UToluene L U LTrichloroacetic acid – R UTrichloroethane – U LTrichloroethylene L – LTrisodium phosphate U L –Turpentine – L RWater R R RXylene – U LZinc chloride L R RZinc sulphate L R R
CHEMICAL POLYAMIDE POLYCARBONATE POLYESTERENVIRONMENT
R=Recommended; L=Limited; U=Unsatisfactory
2.40
0/02