7
WALLS K-600 /A-585 DESCRIPTION K-600/50 K-600/100 K-600/25 A-585/50 ** A-585/25 * Fire Class B-15 B-30 B-15 B-15 B-15 Standard width 600 mm 600 mm 600 mm 585 mm 585 mm Module length up to 3000 mm up to 3000 mm up to 3000 mm up to 3000 mm up to 2500 mm Module width 600 mm 600 mm 600 mm 600 mm 600 mm Thickness 50 mm 100 mm 25 mm 50 mm 25 mm Weight 19.2 kg/m 2 25.2 kg/m 2 13.8 kg/m 2 12.3 kg/m 2 12.7 kg/m 2 Sound reduction R w =32 dB R w =32 dB R w =26 dB R w =27 dB Thermal Insulation U=0.65 W/m 2 K U=0.34 W/m 2 K U=1.16 W/m 2 K U=0.65 W/m 2 K U=1.16 W/m 2 K Application Partition and Lining Partition Partition and Lining Partition and Lining Lining * Alu/Steel **Alu/Alu K-600/25mm/B-15 K-600/50mm/B-15 A-585/50mm/B-15 A-585/25mm/B-15 K-600/2x25mm/A-60 100 mm 20 mm K-600 is designed with integrated joint profiles for rapid installation, leaving a flush surface with single seam joints. Available in standard or modular system. Approved B-15 with cable penetrations available for several wall types. The system have been shock tested. More information available on request. K-panels are also available in aluminium construction in B-15 with considerable weight savings. See technical description below. WEIGHT: All weights are based on system weight, including all profiles. WALLS 0575 [email protected] www.shipinteriorsystems.com 503-789-7599 SHIP INTERIOR SYSTEMS, LLC 1767 12th Street #128 Hood River, OR 97031

Upload: nathan-brennan

Post on 24-Mar-2016

260 views

Category:

Documents


1 download

DESCRIPTION

Norac Bulkheads

TRANSCRIPT

Page 1: Norac USA Bulkheads

Walls

K - 6 0 0 /A - 585

DESCRiPtiON K-600/50 K-600/100 K-600/25 A-585/50 ** A-585/25 * Fire Class B-15 B-30 B-15 B-15 B-15 Standard width 600 mm 600 mm 600 mm 585 mm 585 mm Module length up to 3000 mm up to 3000 mm up to 3000 mm up to 3000 mm up to 2500 mm Module width 600 mm 600 mm 600 mm 600 mm 600 mm thickness 50 mm 100 mm 25 mm 50 mm 25 mm Weight 19.2 kg/m2 25.2 kg/m2 13.8 kg/m2 12.3 kg/m2 12.7 kg/m2

Sound reduction Rw=32 dB Rw=32 dB Rw=26 dB Rw=27 dB – thermal insulation U=0.65 W/m2 K U=0.34 W/m2 K U=1.16 W/m2 K U=0.65 W/m2 K U=1.16 W/m2 K Application Partition and Lining Partition Partition and Lining Partition and Lining Lining

* Alu/Steel **Alu/Alu

K-600/25mm/B-15K-600/50mm/B-15A-585/50mm/B-15A-585/25mm/B-15

K-600/2x25mm/A-60

100 mm20 mm

K-600 is designed with integrated joint profiles for rapid installation, leaving a flush surface with single seam joints. Available in standard or modular system.Approved B-15 with cable penetrations available for several wall types. The system have been shock tested. More information available on request.

K-panels are also available in aluminium construction in B-15 with considerable weight savings.See technical description below.

Weight:All weights are based on system weight, including all profiles.

W

ALLS

0575

[email protected] www.shipinteriorsystems.com 503-789-7599

SHIP INTERIOR SYSTEMS, LLC 1767 12th Street #128 Hood River, OR 97031

Page 2: Norac USA Bulkheads

SOUND REDUCTION WALLS

Q - 6 0 0Q-600 is an acoustic wall system of sandwich construction with an exellent sound reduction quality. Q-600 is a rigid system with integrated joint profiles and allows for easy and rapid installation. Flush surface with single seam joints. Available as a modular system.50 mm panels available with vertical cable ducts in B-15. 70 mm panels have the possibility to draw cables horizontal and vertical.

Weight:All weights are based on system weight, including all profiles.

DESCRiPtiON Q-600/50, 43 dB Q-600/50, 46 dB Q-600/70 CF-600/50 CF-600/70 Fire Class B-15/B-30 B-15/B-30 B-15/B-30 B-15/B-30 B-15/B-30 Standard width 600 mm 600 mm 600 mm 600 mm 600 mm Module length up to 3000 mm up to 3000 mm up to 3000 mm up to 3000 mm up to 3000 mm Module width 600 mm 600 mm 600 mm 600 mm 600 mm thickness 50 mm 50 mm 70 mm 50 mm 70 mm Weight 19.8 kg/m2 21.4 kg/m2 19.9 kg/m2 25.8 kg/m 26.2 kg/m2

Sound reduction Rw = 43 dB Rw = 46 dB Rw = 45 dB Rw = 47 dB Rw = 49 dB thermal insulation U = 0.64 W/m2K U = 0.64 W/m2K U = 0.62 W/m2K U = 0.64 W/m2K U = 0.62 W/m2K Application Partition Partition Partition Partition Partition

Partition only

43-49 dB

Adjusted References Sound Reduction Index(Laboratory measurement)

Q-600/50, 46 dB

W

ALLS

0575

[email protected] www.shipinteriorsystems.com 503-789-7599

SHIP INTERIOR SYSTEMS, LLC 1767 12th Street #128 Hood River, OR 97031

Page 3: Norac USA Bulkheads

Walls

Additional panel concept for installation on existing walls. Ideal for refurbishing purposes, and where a better sound reduction between cabins is required. Thickness 20 mm only.

Weight:All weights are based on system weight, including all profiles.

A d d i t i o n a l p a n e l c o n c e p t

DESCRiPtiON C-600/20 Fire Class C-class Standard width 600 mm Module length up to 3000 mm Module width 600 mm thickness 20 mm Weight 12.4 kg/m2

Sound reduction* 42 up to 51 dB thermal insulation** Application Lining

* Achieved as additional insulation on 28 dB wall.** Depend on existing wall.

Uppgrading of existing cabins

W

ALLS

0575

[email protected] www.shipinteriorsystems.com 503-789-7599

SHIP INTERIOR SYSTEMS, LLC 1767 12th Street #128 Hood River, OR 97031

Page 4: Norac USA Bulkheads

Walls

Strength of hand rails attached to wall panels:

The tongue and groove system allow fixing of heavy objects to the wall without special reinforcement.

Both K-600/25 mm and K-600/50 mm are qualified according to the SOLAS regulation: “Strength test for B-class panels to which handrails are attached on RO-RO passenger ships”.

The result can be transferred to other Norac panel types. The full report is available on request.

General strength properties:

Norac have performed several series of other tests on strength properties. More information is available on request.

L o a d b e a r i n g C a p a c i t y

W

ALLS

0575

[email protected] www.shipinteriorsystems.com 503-789-7599

SHIP INTERIOR SYSTEMS, LLC 1767 12th Street #128 Hood River, OR 97031

Page 5: Norac USA Bulkheads

Walls

P a n e l s f o r w e t s p a c e s

Detail for wet room - 25 mm lining only. 50 mm panels with symmetric finish.

50 mm panels with asymmetric finish.

Standard thickness of flat bar 8 mm, others are available. Flatbar is normally part of the yard’s delivery.

8 mm

15 mm Height according to request

W

ALLS

0575

[email protected] www.shipinteriorsystems.com 503-789-7599

SHIP INTERIOR SYSTEMS, LLC 1767 12th Street #128 Hood River, OR 97031

Page 6: Norac USA Bulkheads

Walls

E x a m p l e o f s t a n d a r d s y s t e mA standard system is a flexible system allowing adjustments onboard the vessel during construction. The panels are delivered in one standard size and are cut to fit according to the on site measurements with use of standard profiles.Profiles are designed to leave as few visible screws/rivets as possible.

Standard profiles, see page 27–30.

W

ALLS

0575

[email protected] www.shipinteriorsystems.com 503-789-7599

SHIP INTERIOR SYSTEMS, LLC 1767 12th Street #128 Hood River, OR 97031

Page 7: Norac USA Bulkheads

INTERNAL ACOUSTIC WALLS

C . i . S 1 H o u r

DESCRiPtiON CiS-25 CiS-50 CiS-100Fire class Non Combustible B30 / 30 mins. A60 / 1 hourStandard width 575 575 575Panel height up to 3000 mm up to 4500 mm up to 6000 mmthickness 25 mm 50 mm 100 mmWeight 14.42 Kg/m2 19.35 Kg/m2 ** 30.62 Kg/m2

Sound reduction Rw= 30 dB Rw= 36 dB Rw= 46 dBthermal insulation U = 1.12 W/m2K U = 0.61 W/m2K U = 0.32 W/m2KApplication Lining Panel Partition Panel ** Partition Panel

Standing for “Clip In System”. It is the ease and speed with which the CIS panel systems are installed and demounted that makes this system the most popular and widely used system in the market place today. All panels within the CIS range are rigid in strength and extremely flexible in cut-ting and installing. Available as a standard or fully modular system.

C.i.S PANELS

Non-load bearing composite firewalls for the offshore and marine industries.The A60 wall doubles as the BD spe-cial acoustic partition system giving a good sound reduction of 46 dB and a good acoustic absorption factor of 1.03 at 500 Hz. The system is certi-fied for use with perforated steel to either one or both panel faces.All weights shown are for the fully installed system and include all pro-files.

DEtAiLS

** Available with light weight insulation core.

B30

A60

20 x 30 Conduit Raceways

Accoustic Membrane

30 / 36 / 46 dB

W

ALLS

0575

[email protected] www.shipinteriorsystems.com 503-789-7599