nox intrusion and access control system
TRANSCRIPT
IP ( GPRS )IP ( Ethernet )NOX - bus ( RS485 )Cable connection
NOX INTRUSION AND ACCESS CONTROL SYSTEMPLANNING ASSISTANCE
8 6 8 1
NOXMIO included in the control unit
NOXSYS G3Intrusion control unit
NOXXL G3Intrusion control unit
10 000
S 4 000
20 BUS
Any
A H2 × 17 Ah
100 000
400
10 000
S 4 000
20 BUS
Any
A H2 × 40 Ah
100 000
400
10 000
10 000
Dimensions:604 × 404 × 105 mm
Dimensions: 700 × 500 × 205 mm
Central components
1 1
2 2
3 3
Remote accessNOX Remote Access
Police emergency and service control centres
NTP time server
Connection to third-party systemsModbus / SIA IP / SSH / ESPA 4.4.4
3rd
Installation and serviceConfiguration tool
Management systems
NOXSIMSControl system
Third - party systemsFull integration of multiple manufacturers
TR
AN
SM
ISS
ION
RO
UT
E
Vers
ion
1.0
| 0
6/20
18
NOXTPATouch-panel control-ler 15 with graphic operating software
NOXCPC - MComfort control panel with integrated card reader
NOXUPEPIN - code keypad in Feller Edizio design
NOXTXOOptical wireless picture alarm
NOXLRGWireless gateway with LoRa®
NOXRXPParadox wireless gateway
NOXAOSStand-alone variant for local security
NOXKPDIlluminated PIN - code keypad with function keys
NOXUPKKey switch with indicator LEDs
12 V / 240 V
PC TPAPC licence for the graphic operating software on an external computer
PC control panelOperating software without graphic support
Mobile apps NOXMXAIP Ethernet bus extender
NOXPS5 G3Additional power supply
NOXRPT G3Bus repeater and serial interface
NOXIR3Bus connection for motion detector, PDM series
NOXM31Mini input / output module
NOXGM7Bus connection for noise detector, GM7xx series
NOXESPSerial interface RS232 ESPA 4.4.4
NOXBus connectionCable type, min. U72 1 × 4 × 0.5
35 ×Bus 4
127 ×
20 ×
NOXXL G3 NOXSYS G3 NOXONE G3
NOXPS5 XLAdditional power supply
Dimensions:700 × 500 × 205 mm
NOXPS5Additional power supply
Dimensions: 604 × 404 × 105 mm
NOXPS1Additional power supply
Dimensions: 380 × 240 × 101 mm
8
8
6
1
NOXMIO G2Multi I / O board with Wiegand interface
32
NOXO32Output module for LED activation
NOXAN1Analog input module, 0 - 10 V
NOXTHSIModule for measuring temperature and humidity
NOXIO1Input and output module 1 × input and 1 × relay output, potential free
NOXFLDWater detector
4 4
NOXIO4 G3Input and output module, 4 × inputs and 4 × open-collector outputs, 350 mA each
4
NOXRE4 G3Output module4 freely programmable electronic relay outputs
1
1
3
1
1
204
1
1
3
1
2
204
NOXCMUCard reader interface, Wiegand protocol
NOXCMOCard reader interface, OSDP protocol
• Links of messages in the system: AND, OR, NOT, DELAY, MAX, MIN
• Flexible generation of new functional sequences, e.g. of sluice controls
• Equations can be exported and imported
Example of a control
AND
Message 1
Delay time
Message 2 Message 3
Output 1
OR
1 200 m - ( can be extended )
A H
Primary inputs
Switch outputs
Relay outputs
Video cameras
User
Card reader
Offline memory
Battery capacity
S Secured areas
Control units
Doors
Links
Calendar functions
Outputs
Inputs
Encryption
Hardware features
Legend
Software features
2 × 40A H
2 × 17A H
2 × 17A H
Wireless handheld transmitters
Code reader / biometric system
Magnetic contact
Motion detectors
Glass breakage detectors
Fire detectors
External switching devicesBlock lock, electric opener, motorised lock
Door monitoringMagnetic contact, locking contact
1 × 17A H
EN 50131-G3
VdS-C
SSF 1014 ed. 5VSÖ
EN 50131-G3
VdS-C
SSF 1014 ed. 5VSÖ
EN 50131-G3
SSF 1014 ed. 5VSÖ
EN 50131-G3
EN 50131-G3
VdS-C
SSF 1014 ed. 5VSÖ
EN 50131-G3
VdS-C
SSF 1014 ed. 5VSÖ
EN 50131-G3
EN 50131-G3
VdS-C
SSF 1014 ed. 5VSÖ
EN 50131-G3
VdS-C
SSF 1014 ed. 5VSÖ
EN 50131-G3
SSF 1014 ed. 5VSÖ
EN 50131-G3
VdS-C
SSF 1014 ed. 5VSÖ
EN 50131-G3
VdS-C
SSF 1014 ed. 5VSÖ
EN 50131-G3
SSF 1014 ed. 5VSÖ
EN 50131-G3
VdS approved
EN 50131-G3
VdS-C
SES approved
SSF 1014 ed. 5VSÖ
EN 50131-G3
VdS-C
VSÖ approved
SSF 1014 ed. 5VSÖ
EN 50131-G3 SBSC approved
SSF 1014 ed. 5VSÖ
EN 50131-G3
Control panels / indicator Control - unit networkingInfrastructure components
NOX - bus detector components127 elements per bus, max. 200 elements per bus with repeater
Interfaces / repeaters Power supplies
Picture alarm system Wireless operation Access control Input / output modules
Complex controllers / equation editor
9 ×
2 000 Stk.
EN 50131-G3
VdS-C
SSF 1014 ed. 5VSÖ
EN 50131-G3
VdS-C
SSF 1014 ed. 5VSÖ
EN 50131-G3
SSF 1014 ed. 5VSÖ
EN 50131-G3
EN 50131-G3
VdS-C
SSF 1014 ed. 5VSÖ
EN 50131-G3
VdS-C
SSF 1014 ed. 5VSÖ
EN 50131-G3
EN 50131-G3
VdS-C
SSF 1014 ed. 5VSÖ
EN 50131-G3
VdS-C
SSF 1014 ed. 5VSÖ
EN 50131-G3
+ |
AB
+UB0 V
RS 485RS 485
NOXSYSTEMS PLANNING ASSISTANCE
Nox Systems AG
Alvierweg 17 | 9490 Vaduz | Liechtenstein | Tel + 423 370 25 25 | [email protected] | www.noxsystems.com
1
3
2
For a lasting partnershipAll of the components are carefully developed and are impressive thanks to their high durability. These high - quality products from NOX Systems come with a three - year warranty. The company also provides a 10 - year spare parts warranty on NOX products.
NOX Systems is a young, dynamic team of specialists with vast experience and expertise in the security industry. The consistent quality of our products and services is the focus of our work. The products we develop and offer are produced locally. This allows us to provide the performance that our customers all over Europe have come to value. NOX Systems offers customised security to meet the highest standards.
To ensure the highest level of security, our systems are subject to continuous further development in our own estab-lishment. Our know - how builds the basis for new innovations. All components are produced to the highest standards of quality, functionality and design. The result: maximum security and simple operation. We put great emphasis on stable, traditional values, a trusting relationship with employees, customers and suppliers as well as protection of the environment and our natural resources.
For the highest standardsThe NOX SYS was developed to meet the highest security standards. The system is certified in the highest class in accordance with EN 50131 grade 3 and class C of the VdS standards, and is recognised by the SES, VdS, VSÖ and SBSC associations. Many banks, office buildings, department stores, art galleries and residential buildings rely on it. The systems are continually further developed and adapted in line with current technical and IT threat situations.
Are you already a NOX customer?Do you already have a NOX alarm system? Not a problem. Just add the NOX ONE as a « slave control unit » at another location and manage your system as usual via your user interface. You are not dependent on any particular manufacturer when it comes to select-ing your detectors, sensors and readers for your alarm system.
YOU ARE RIGHT TO FEEL GOOD.
ABOUT US.
NOXSYSTEMS
NOXSYSTEMS
Consultation Speak to a specialised installer about your personal requirements and ideas to find the best possible individual solution together. You can find our select partners at noxsystems.com
24 - hour service Our specialist partners offer the best possible support and service should a problem arise.
Installation A trained expert installs the NOX SYS control unit and your selected modules. You are then provided with initial training on how to use the system.
Your specialist partner