nxio platform f r om “oemax nxio introduction cn rev4”
DESCRIPTION
NXIO Platform f r om “OEMax NXIO Introduction CN rev4.ppt”. Thomas Sugimoto Strategic Marketing Manager. Outline. PLC I/O Market Trends Birth of Distributed I/O NXIO 2 nd Generation Distributed I/O Product Features Target Market How to use NXIO to reduce costs Internal Quality. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/1.jpg)
TM
SMMaximum Value for OEMsMaximum Value for OEMs
Maximum Value for OEMsSM
NXIO PlatformNXIO Platform
ffrrom “OEMax NXIO Introduction CN rev4.ppt”om “OEMax NXIO Introduction CN rev4.ppt”
Thomas Sugimoto
Strategic Marketing Manager
Thomas Sugimoto
Strategic Marketing Manager
![Page 2: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/2.jpg)
2
OutlineOutline
PLC I/O Market TrendsBirth of Distributed I/O
NXIO 2nd Generation Distributed I/O
Product FeaturesTarget Market
How to use NXIO to reduce costs
Internal Quality
![Page 3: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/3.jpg)
3
PLC I/O Trends
![Page 4: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/4.jpg)
4
Large End Users and Complex OEMs are looking for ways to further reduce their costs
Hardware PLC and I/O costs keep decreasing so now Space, Labor and Maintenance of I/O Wiring is becoming a major cost
Networked I/O Trend
PLC I/O TrendsPLC I/O Trends
PLC HW COSTS - DOWN
SPACE, WIRING COSTS - UP
Large Factories - Refineries - Automotive
Complex MachineOEMs
![Page 5: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/5.jpg)
5
Customers purchasing I/O as a ComponentCustomers can buy any PLC Controller and use any I/O platform due to emergence of Global Network Standards (e.g. Profibus, DeviceNet)
e.g. Controller is Brand ZZZ and I/O is OE Max NXIO
PLC I/O TrendsPLC I/O Trends
Servo
OE Max Controls Bridge
OE MAXControls
NXPLC
NXIOBrandZZZ
BrandAAA
![Page 6: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/6.jpg)
6
Birth of the Distributed I/O Concept
![Page 7: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/7.jpg)
7
Improvement over PLC I/OImprovement over PLC I/O
Birth of “Distributed I/O” Concept to reduce Wiring costs
Combination of Network + Modular I/O + Terminal Block (TB)Network provides Diagnostic Data back to Controller for easy Maintenance
PLCController
NetworkMaster Network
Slave
NetworkSlave
I/O I/O I/O I/O
TB TB TB TB
I/O I/O I/O I/O
TB TB TB TB
Distributed I/O
![Page 8: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/8.jpg)
8
Improvement over PLC I/OImprovement over PLC I/O
Popular for over 10yrs in North America and Europe where space and labor are very expensive
Trend will continue into ChinaGrowing Number of Large Factories (e.g. Automotive, Food and Beverage) with Networking Requirements
Labor and Space Costs will increase over time
Productivity (not just low cost labor) will become a Competitive Advantage
Many Terminal Block or Sensor Suppliers start to sell Distributed I/O platforms
WAGO, Phoenix Contact, Beckhoff, Turck, Opto22
but they lack a PLC background
![Page 9: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/9.jpg)
9
NXIO
2nd Generation Distributed I/O Design
![Page 10: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/10.jpg)
10
PLC I/O PLC I/O 市场趋势市场趋势
The trend for the Semiconductor OEMs is to adopt Distributed I/O
DeviceNet is adopted as a Semiconductor Standard and has become very popular in Asia and North AmericaSaves on space and wiring
OE Max Controls launches NXIO in 20042nd Generation Distributed I/O DesignSlice-type with high granularity of I/O
![Page 11: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/11.jpg)
11
NXIO Specifications
![Page 12: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/12.jpg)
12
Product FeaturesProduct Features
Save spaceSmall Footprint1, 2, 4, 8, 16 point I/O ModulesExpansion up to 32 slots
Various I/O TypesDiscrete I/O: 24Vdc, Relay, Triac, SSRAnalog I/O: Current and VoltageThermo-couple, RTD inputHigh Speed Counter
![Page 13: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/13.jpg)
13
Easy to useProtected OutputRemovable Terminal BlockEasy wiring
Network ConnectivityDeviceNetProfibus-DPOthers: CanOpen, EtherNet/IP
CertificationsCE, UL, cTick
Product FeaturesProduct Features
![Page 14: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/14.jpg)
14
Product SpecificationsProduct Specifications
![Page 15: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/15.jpg)
15
Product FeaturesProduct Features
Field power
Removable Terminal Block
*
*
*
*
COM connectionDin-Rail Lock
Din-Rail&
Frame Ground
Sliding expansion
Color Code
Communication Status
I/O Status LEDOne-Touch Wiring
Test Pin
3 wire device
2 wired device
![Page 16: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/16.jpg)
16
Product FeaturesProduct Features
① Removable terminal block
② One-Touch Cabling without Screw Driver
③ Separated field power
④ Easy wiring for COM connection
⑤ I/O Status LED
⑥ Module identifier by color coding
⑦ Test pin for Easy and Safe operation
⑧ Sliding I/O expansion without Screw Driver
⑨ DIN-rail installation
⑩ Frame Ground to enhance noise immunity
Easy Wiring
Faster maintenance
Enhanced Structure
![Page 17: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/17.jpg)
17
Target MarketNXIO is not only for highly distributed
applications. Wherever you need networked I/O, you can use NXIO
![Page 18: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/18.jpg)
18
Target MarketsTarget Markets
DeviceNet MarketSave space (network power for sensors)
Motor Control Centers (overload diagnostics)
Semiconductor, Electronics Industry
Profibus DP MarketCost Reduction from using Siemens ET200 I/O
High Performance
SCADA (Supervisory Control and Data Acquisition)
DCS (Process Control – Distributed Control System)
Outdoor Applications (-20C to 55C Rating)
Future: Modbus TCP (Ethernet), Modbus Plus
![Page 19: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/19.jpg)
19
Target MarketsTarget Markets
Large Variety of Control Solutions
PLC
PC Based
Soft PLC
Web Based
VME Controller
Compact PCI
HMI
PC
![Page 20: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/20.jpg)
20
Advantages of using NXIOHow to use NXIO to reduce costs - At the same time improve the overall value of your
system.
![Page 21: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/21.jpg)
21
Lowering Your Total PLC HW CostLowering Your Total PLC HW Cost
Easy way to lower Total HW Cost is to use NXIO with your current Control Solution
Keeping same PLC minimizes redesign of system
Cost Reduction ExampleContinue to use Siemens S7-315DP Controller with Profibus
Replace Siemens ET-200 I/O (typically M or S series) with NXIO
S7-315DP Controller
S7-200M (S7-300) + Terminal Block
ProfibusNetwork
NXIO- Smaller- Easier to wire- Lower Cost
![Page 22: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/22.jpg)
22
Reduce your Labor CostsReduce your Labor Costs
Internal Field Power Bus eliminates extra Wires for Commons
Reduces wiring by over 25%Reduces wiring mistakes
Special Modules available for wiring Analog ShieldsNo extra terminal blocks needed for wiring
NXIO is a Terminal Block
“Spring Clamp” Terminal Block design eliminates need for Screwdriver
Guarantees good connection even under vibration
![Page 23: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/23.jpg)
23
Eliminate Wasted/Unused I/O PointsEliminate Wasted/Unused I/O Points
With Traditional PLC I/O platforms, I/O Points and Space can be wasted
e.g. Need 480pts of Digital I/O but only 2 Analog I/O and 1 High Speed Counter
NXIO is highly configurable
16pt Digital I/O
1 Channel HSC
2 Channel Analog
This lowers HW costs and saves Cabinet Space
Typical PLC16pt I/O Module
NXIO16pt ModuleSmaller Size
![Page 24: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/24.jpg)
24
The Quality InsideLet’s look inside NXIO
![Page 25: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/25.jpg)
25
Superior Vibration ResistanceSuperior Vibration Resistance
WAGO/BeckHoff
(Press fit type) (Contact Type)
OE Max
“Press fit” structure provides superior vibration resistance
![Page 26: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/26.jpg)
26
Optimized Communication ProtocolOptimized Communication Protocol
Reduced hardware cost by serial communication.
Efficient protocol for rapid response time – Change of State Inputs
Service Message Frame
I/O Message Frame
MessageHeader
MessageLength
FunctionCode
Service Data Field CRC 8
MessageHeader
I/O Data Field CRC 8MessageLength
Adapter
Slot#1
Output Data by Broadcasting
Slot#2 Slot#3 Slot#4 Slot#5 Slot#6
‘1
2
‘2
3
‘3
4
‘4
5
‘5 ‘6
Input Data sent using Change of State when Token is received
InputToken
1
![Page 27: NXIO Platform f r om “OEMax NXIO Introduction CN rev4”](https://reader035.vdocuments.net/reader035/viewer/2022062221/568145aa550346895db2a18b/html5/thumbnails/27.jpg)
27
TM
Maximum Value for OEMsSM