Page 1: O rto  T ech  D esign Ltd

Orto Tech Design Ltd.

RIGID MONOFIXATOR

MODEL ‘RAPID’

Page 2: O rto  T ech  D esign Ltd

TITLE PAGE OF THE PATENT

Page 3: O rto  T ech  D esign Ltd

GENERAL

The Rigid Monofixator is designed for orthopaedics and thraumatic surgery and is applied in treatment of long tubular bones.

The fixator is the fastest way of stabilizing, using the method of remote osteosynthesis of two fragments - with tightening of just one nut, a reliable fixation is achieved with unlimited number of bone screws.

Page 4: O rto  T ech  D esign Ltd

ADVANTAGES

Simple, reliable, light, versatile system.

Effective in healing of different types of displaced fractures

Very easy to apply within a short operative period.

Ensures hopeful fixation in fractures in reduction position.

Universal with respect to the choice of implant screws - it allows

tightening of screws from 3 mm to 6 mm in diameter.

Opportunity to choose freely where to mount the screws: quite near the

fracture line and as far from it as possible. Thus long carrying arms can

be formed ensuring maximum stability on the axis.

Isolator property achieved by hard anodized coating with Al2O3

Page 5: O rto  T ech  D esign Ltd

DESIGN

The design of the fixator is compact and has been simplified to the highest degree, allowing quick immobilization of moving bone fragments. The fixator contains of a carrier, shaped as a thin-wall tube (2), containing a body (1) with holes, shaped in it. Bone screws (3) are fixed in (A) and (B) holes by means of a nut (4). Thus remote rapid ostheosynthesis is achieved. The body can move axially in relation to the tube, but it cannot turn around. This is assured by a pin (5) which moves in a groove .

Page 6: O rto  T ech  D esign Ltd

SCREW DESIGN

Implant screws are combinations of a drill 1, screw tap 2 and screw 3. That allows screws to be fixed into the bone without preliminary preparation. At the beginning the screw is with an arc profile that slightly turns into cylindrical one.

The threading of the screw is with a special self-locking profile that ensures the preservation of maximum osseous tissue.

The end of the screw is with a triangular profile that allows fitting to a wrench with the same profile or to a three-jaw chuck.

1 2 3

Page 7: O rto  T ech  D esign Ltd

APPLICATION AREA

The Rigid Monofixator could be applied in following

cases: open and closed fractures in different places;

single and multiple fractures;

in-joint and out-joint fractures;

fractures with infections;

unhealed fractures and complex joints (pseudoarthrosis);

Page 8: O rto  T ech  D esign Ltd

APPLICATIONS

PHALANGES FRACTURES

Page 9: O rto  T ech  D esign Ltd

APPLICATIONS

PHALANGES FRACTURES

Page 10: O rto  T ech  D esign Ltd

APPLICATIONS

JAWS FRACTURES

Page 11: O rto  T ech  D esign Ltd

APPLICATIONS

ANTEBRACHIUM AND HUMERUS FRACTURES

Page 12: O rto  T ech  D esign Ltd

APPLICATIONS

TIBIA AND FEMUR FRACTURES

Page 13: O rto  T ech  D esign Ltd

OPERATING MANUAL

1. Operation planning2. Before the operation, concerning the plan, the orthopaedic surgeon chooses the necessary modules from the set and prepares them for sterilisation.3. Sterilisation is done according to the instructions:

Sterilisation approach Implants Fixators InstrumentsUnder pressure Yes Yes YesTermal Yes No YesWith X rays Yes Yes YesWith gas Yes Yes YesChemical Yes Yes Yes

4. Fixators are arranged on a surgical table, in accordance with technology, described in the operation plan.5. Treat the patient.

PREPARING STAGE

Page 14: O rto  T ech  D esign Ltd

OPERATING MANUAL

Depending on the position, character and complexity of a particular fracture, the necessary number of screws are inserted in the bones so that they should be against the holes of the fixator. Two of them are placed over and under the fracture line, in the fracture area, the rest are placed as far from the fracture as possible.

Guiders and protectors are used for more precise insertion and protection of the soft tissues from additional damage and traumata.

The screws should pass through the whole bone, but they shouldn’t penetrate into the opposite soft tissue.

After the screws’ insertion, the fixator is strung on the protruding screw stems and the fixator nut is tightened. Thus all the screws are tightened simultaneously and the bone fragments are stabilized. Because of the parallel misalignment of the screws increased solidity of tightening is achieved as a result of the wedging.

OPERATING WITH THE SET ‘RIGID MONOFIXATOR’

Page 15: O rto  T ech  D esign Ltd

OPERATING MANUAL

OPERATING WITH THE SET ‘RIGID MONOFIXATOR’

screwing a screw strunging a fixator tightening

Page 16: O rto  T ech  D esign Ltd

OPERATING MANUAL

Depending on the volume, size and strength of the broken bones, we propose a method for choosing the appropriate screws based on the following principle: not more than one third of the local bone thickness:

Bone Screw diameter [mm] Phalanges of the hands and feet /metacarpal, 2 or 3

metatarsal, heel bones/ Radius and ulna 3 or 4 Distal epiphysis of radius and proximal epiphysis of ulna 4 or 5 Distal epiphysis of humerus 4 Diaphyasis and proximal metadiaphyasis of humerus 4; 5 or 6 Femur 5 or 6 Pelvic bones 5 or 6

CHOOSING THE NECESSARY SCREWS

Page 17: O rto  T ech  D esign Ltd
Page 18: O rto  T ech  D esign Ltd

MODULES

cat. № Name

803000 Module with 9 holes

803000-01 Module with 11 holes

803000-02 Module with 13 holes

803000-03 Module with 15 holes

803000-04 Module with 17 holes

803000-05 Module with 19 holes

SET FOR UPPER EXTREMITY

Page 19: O rto  T ech  D esign Ltd

MODULES

cat. № Name803100 Module with 9 holes803100-01 Module with 11 holes803100-02 Module with 13 holes803100-03 Module with 15 holes803100-04 Module with 17 holes803100-05 Module with 19 holes803100-06 Module with 21 holes

SET FOR LOWER EXTREMITY

Page 20: O rto  T ech  D esign Ltd

MODULES

cat. № Name803200 Module with 4 holes803200-01 Module with 5 holes803200-02 Module with 6 holes803200-03 Module with 7 holes803200-04 Module with 8 holes803200-05 Module with 9 holes803200-06 Module with 10 holes

SET OF MINIFIXATORS

Page 21: O rto  T ech  D esign Ltd

SCREWS

cat. № Name700200-02 Ø 4 mm L 80/20 700200-03 Ø4 mm L 90/20 700200-04 Ø4 mm L 100/25 700200-05 Ø4 mm L 110/25700400-01 Ø5 mm L 90/30700400-03 Ø5 mm L 100/35700400-05 Ø4 mm L 110/35 700400-07 Ø5 mm L 120/40700400-09 Ø5 mm L 130/45700500-01 Ø6 mm L 90/30700500-03 Ø6 mm L 100/35 700500-15 Ø6 mm L 110/40 700500-07 Ø6 mm L 120/40700500-09 Ø6 mm L 130/40 700500-11 Ø6 mm L 140/40700500-13 Ø6 mm L 150/45700500-15 Ø6 mm L 160/50

Page 22: O rto  T ech  D esign Ltd

CANNULATED SCREWS

cat. № Name

700600-01 Ø6 mm L 90/30700600-03 Ø6 mm L 100/35 700600-05 Ø6 mm L 110/40 700600-07 Ø6 mm L 120/40700600-09 Ø6 mm L 130/40 700600-11 Ø6 mm L 140/40700600-13 Ø6 mm L 150/45700600-15 Ø6 mm L 160/50

Page 23: O rto  T ech  D esign Ltd

KIRSHNER WIRE WITH ROUND END

cat. № Name

790100 Ø1.5 mm L 70

790100-01 Ø2.0 mm L 70

790100-02 Ø2.2 mm L 70

790100-03 Ø2.2 mm L 70

Page 24: O rto  T ech  D esign Ltd

INSTRUMENTS

Page 25: O rto  T ech  D esign Ltd

INSTRUMENTS

cat. № Name qty.900100-01 Wrench 8 1900100-08 Wrench 15 1900100-09 Wrench 17 1900300 Blocking bar 1 905100-01 Screw wrench Ø 4 1905100-02 Screw wrench Ø 5 1905100-03 Screw wrench Ø 6 1909200 Wrench for trocars and protectors 1901400 Guide 1901500 Guide for Kirshner wires 1922100-01 Protector short Ø 4 4922100-02 Protector short Ø 5 4922100-03 Protector short Ø 6 4923000-01 Trocar Ø 4 4923000-02 Trocar Ø 5 4923000-03 Trocar Ø 6 4

Page 26: O rto  T ech  D esign Ltd
Page 27: O rto  T ech  D esign Ltd

CLINICAL CASE #1

R.A. 28 year old, d.r. No 1145/28.10.1995

Dg. Osteomielitis femuris hronika fistulosa. Fistula.

Chronic thraumatic purulent osteitis of the femur after intramedular osteosynthesis a modo Kuntscher. Engagement of the medular canal and unstable synthesis is seen from the fistulo-graphia. Micrbiologic examination - staphylococcus pureus. Strong necessity of external fixation and removing the nail. The medular canal is strip-drilled and cleaned with antiseptic solutions. Gentamycin pearls (PMMA) are mounted for preparing of the implantation place. After fistulectomia the wound is closed hermetically.

Page 28: O rto  T ech  D esign Ltd

CLINICAL CASE #1

Page 29: O rto  T ech  D esign Ltd

CLINICAL CASE #1

Redon drainage in the canal from the proximal femur. On the 20 th day PMMA are removed and the place is filled with graft from spina ilacia anterior superior, and the donor place is filled with graft from the bone bank /Popkirov/. Redon drainage for 7 days. Smooth postoperative period. Early limb loading. Infection - under control.

Page 30: O rto  T ech  D esign Ltd

CLINICAL CASE #1

Five months later roentgenography shows graft reconstruction. Bone defect recovery. Removed external fixator. Full rehabilitation. Excellent results.

Page 31: O rto  T ech  D esign Ltd

CLINICAL CASE #1

Page 32: O rto  T ech  D esign Ltd

CLINICAL CASE #1

Indications:1. Corrupted intramedular synthesis.2. Thraumatic purulent osteitis.3. Wide access to the wound, allowing second operation and wound observation.4. Early moving of neighbour joints.

Page 33: O rto  T ech  D esign Ltd

CLINICAL CASE #2

Page 34: O rto  T ech  D esign Ltd

CLINICAL CASE #2

Page 35: O rto  T ech  D esign Ltd

CLINICAL CASE #2

Page 36: O rto  T ech  D esign Ltd

CLINICAL CASE #2

Page 37: O rto  T ech  D esign Ltd

CLINICAL CASE #2

Page 38: O rto  T ech  D esign Ltd

CLINICAL CASE #2

Page 39: O rto  T ech  D esign Ltd

CLINICAL CASE #2

Page 40: O rto  T ech  D esign Ltd

CLINICAL CASE #2

Page 41: O rto  T ech  D esign Ltd