OCCUPATIONAL HEALTH AND WELLNESS CENTER · remove existing cmu & gyp. bd. on furring to accommodate new addition and provide new masonry lintel, bottom at 7'-4" a.f.f. remove existing
7
HILLSBOROUGH COUNTY SHERIFF'S OFFICE OCCUPATIONAL HEALTH AND WELLNESS CENTER 9550 EAST COLUMBUS DRIVE TAMPA, FLORIDA 33619 RFP 12-18 HEALTH CENTER ADDITION AND RENOVATIONS ADDITION AND INTERIOR RENOVATIONS TO: CHAD CHRONISTER, SHERIFF DATE: FEBRUARY 20, 2018 DESIGN DEVELOPMENT DOCUMENTS - EXHIBIT-A
DATE: FEBRUARY 20, 2018DESIGN DEVELOPMENT DOCUMENTS - EXHIBIT-A
HILLSBOROUGH COUNTY
SHERIFF'S OFFICE
CHAD CHRONISTER, SHERIFF
P.O. BOX 3371
TAMPA, FLORIDA 33601
www.hcso.tampa.fl.us
PREPARED BY:
PROJECT PHASE:
DRAWN BY:
REVISIONS:
HILLSBOROUGH COUNTY SHERIFF'S OFFICE
GENERAL
SERVICES
FACILITIES
MAINTENANCE
UNIT
DESIGN
DEVELOPMENT
SHEET NAME:
SHEET NUMBER:
a.cordova
ISSUE DATE:
PROJECT:
ADDITION & RENOVATION TO:
OCCUPATIONAL
HEALTH
AND
WELLNESS
CENTER
2214 N. FALKENBERG ROAD
TAMPA, FLORIDA 33619
02-20-2018
SEE GRAPHIC SCALE
SITE SURVEY
A-2.1
SITE SURVEY
EXHIBIT - A
SHEET LIST:
A-2.1
A-2.15
A-2.2
A-5.1
A-5.2
A-10.1
HILLSBOROUGH COUNTY
SHERIFF'S OFFICE
CHAD CHRONISTER, SHERIFF
P.O. BOX 3371
TAMPA, FLORIDA 33601
www.hcso.tampa.fl.us
PREPARED BY:
PROJECT PHASE:
DRAWN BY:
REVISIONS:
HILLSBOROUGH COUNTY SHERIFF'S OFFICE
GENERAL
SERVICES
FACILITIES
MAINTENANCE
UNIT
DESIGN
DEVELOPMENT
SHEET NAME:
SHEET NUMBER:
a.cordova
ISSUE DATE:
PROJECT:
ADDITION & RENOVATION TO:
OCCUPATIONAL
HEALTH
AND
WELLNESS
CENTER
2214 N. FALKENBERG ROAD
TAMPA, FLORIDA 33619
02-20-2018
SEE GRAPHIC SCALE
SITE TOPOGRAPHIC SURVEY
A-2.15
SITE TOPOGRAPHIC SURVEY
EXHIBIT - A
SHEET LIST:
A-2.1
A-2.15
A-2.2
A-5.1
A-5.2
A-10.1
EXISTING
CLINIC
PROPOSED
ADDITION
FUTURE
EXPANSION
AVAILABLE
AREA FOR
WATER
RETENTION
EXISTING
METAL
BUILDING
ONE WAY
ONE WAYONE WAY
TWO WAY
TWO WAY
TWO WAY
TWO WAY
TWO WAY
TWO WAY
TWO WAY
DO NOT
ENTER
DO NOT
ENTER
O N
L
Y
3,200 SQ FT.
1,600 SQ FT.
1,600 SQ FT.
HILLSBOROUGH COUNTY
SHERIFF'S OFFICE
CHAD CHRONISTER, SHERIFF
P.O. BOX 3371
TAMPA, FLORIDA 33601
www.hcso.tampa.fl.us
PREPARED BY:
PROJECT PHASE:
DRAWN BY:
REVISIONS:
HILLSBOROUGH COUNTY SHERIFF'S OFFICE
GENERAL
SERVICES
FACILITIES
MAINTENANCE
UNIT
DESIGN
DEVELOPMENT
SHEET NAME:
SHEET NUMBER:
a.cordova
ISSUE DATE:
PROJECT:
ADDITION & RENOVATION TO:
OCCUPATIONAL
HEALTH
AND
WELLNESS
CENTER
2214 N. FALKENBERG ROAD
TAMPA, FLORIDA 33619
02-20-2018
SCALE: 1/16" = 1'-0"
PARTIAL SITE PLAN
A-2.2
PARTIAL SITE PLAN
AERIAL PHOTOS
GENERAL NOTES
EXHIBIT - A
SHEET LIST:
A-2.1
A-2.15
A-2.2
A-5.1
A-5.2
A-10.1
AutoCAD SHX Text
RELOCATE EXISTING FENCE LINE TO THE NORTH ALIGNED W/ TOE OF RAMP BEYOND
AutoCAD SHX Text
RELOCATE EXISTING ROLLING GATE
AutoCAD SHX Text
NEW PR. 6 FT. GATES
AutoCAD SHX Text
STRIPE FOR (7) 10' X 25' PARALLEL PARKING SPACES
AutoCAD SHX Text
REMOVE CONCRETE CURBING & INSTALL (5) NEW ASPHALT PARKING SPACES & NEW CURBS
AutoCAD SHX Text
5 FT. WIDE CONCRETE WALK
AutoCAD SHX Text
5 FT. WIDE CONCRETE WALK
AutoCAD SHX Text
4 FT. WIDE CONCRETE WALK
AutoCAD SHX Text
4 FT. WIDE CONCRETE WALK
AutoCAD SHX Text
4 FT. WIDE CONCRETE WALK
AutoCAD SHX Text
NEW 5 FT. WIDE CONCRETE WALK
AutoCAD SHX Text
REMOVE EXISTING CONCRETE WALKS THIS AREA
AutoCAD SHX Text
REMOVE EXISTING CONCRETE WALK THIS AREA
AutoCAD SHX Text
EXISTING ROLLING GATE & FENCE TO REMAIN
AutoCAD SHX Text
RELOCATE EXISTING ABOVE GROUND PROPANE TANK
AutoCAD SHX Text
A.THE EXISTING SITE AND PROPOSED IMPROVEMENTS THE EXISTING SITE AND PROPOSED IMPROVEMENTS SHALL REVIEWED AND ADJUSTED TO MEET ALL LOCAL, STATE, AND FEDERAL REQUIREMENTS HAVING JURISDICTION INCLUDING SWFWMD. B.THE SITE SHALL BE ANALYZED TO RELATIVE TO THE THE SITE SHALL BE ANALYZED TO RELATIVE TO THE NEW IMPERVIOUS AREA BEING ADDED AND DETERMINE THE ACTUAL AREA REQUIRED FOR ON-SITE WATER RETENTION. AN AREA HAS BEEN DESIGNATED FOR WATER RETENTION, ACTUAL SIZE TO BE DETERMINED BY A CIVIL ENGINEER. C.THE EXISTING SEPTIC SYSTEM SHALL BE REVIEWED TO THE EXISTING SEPTIC SYSTEM SHALL BE REVIEWED TO DETERMINE IF ADDED FIXTURES CAN BE SUPPORTED BY THE EXISTING SYSTEM'S CAPACITY. D.THE FENCE LINE SHOWN TO BE RELOCATED IS TO THE FENCE LINE SHOWN TO BE RELOCATED IS TO FACILITATE FIRE DEPARTMENT TURN AROUND SPACE AND TO ALLOW BETTER ACCESS AROUND THE SITE FOR STAFF AND PATRONS. E.THE SITE SHALL BE INVESTIGATED FOR UNDERGROUND THE SITE SHALL BE INVESTIGATED FOR UNDERGROUND UTILITIES AND SERVICES THAT MIGHT AFFECT CONSTRUCTION OF THE ADDITION AND PARKING AREAS.
PROPOSED ADDITION TO:
PLAN LEGEND
EXISTING LAYOUT
(BEFORE)
AUDIO
BOOTH
STAFF
TOILET
HVAC
EQUIP.
X-RAY ROOM
NURSE PRACTIONER
OFFICE MANAGER
MEDICAL
SUPPLY
STORAGE
MEDICATION
STORAGE
NURSE PRACTIONER
STORAGE STORAGE
EXISTING LAYOUT
(BEFORE)
fgggggg
WALL LEGEND - EXISTING WALL LEGEND - NEW
SCALE: 1/8" = 1'-0"
S
S
S
S
DEMOLITION LEGEND
EXISTING
DEMO
HILLSBOROUGH COUNTY
SHERIFF'S OFFICE
CHAD CHRONISTER, SHERIFF
P.O. BOX 3371
TAMPA, FLORIDA 33601
www.hcso.tampa.fl.us
PREPARED BY:
PROJECT PHASE:
DRAWN BY:
REVISIONS:
HILLSBOROUGH COUNTY SHERIFF'S OFFICE
GENERAL
SERVICES
FACILITIES
MAINTENANCE
UNIT
DESIGN
DEVELOPMENT
SHEET NAME:
SHEET NUMBER:
a.cordova
ISSUE DATE:
PROJECT:
ADDITION & RENOVATION TO:
OCCUPATIONAL
HEALTH
AND
WELLNESS
CENTER
2214 N. FALKENBERG ROAD
TAMPA, FLORIDA 33619
02-20-2018
DATE: 1/20/2018
PROPOSED ADDITION TO:
EXISTING FLOOR PLAN
A-5.1VIEW DETAILS OF NURSES STATION AREA
SCALE: 1/8" = 1'-0"
SCALE: 1/8" = 1'-0"
EXHIBIT - A
SHEET LIST:
A-2.1
A-2.15
A-2.2
A-5.1
A-5.2
A-10.1
AutoCAD SHX Text
36"H. TYP
AutoCAD SHX Text
30"H. TYP
AutoCAD SHX Text
EXISTING CLINC TO REMAIN
AutoCAD SHX Text
EXISTING AREA REMODELED W/ADDITION
AutoCAD SHX Text
PROPOSED NEW ADDITION & REMODELED AREAS
AutoCAD SHX Text
NEW CONCRETE WALK
AutoCAD SHX Text
EXISTING CMU & GYP. BD. ON FURRING
AutoCAD SHX Text
EXISTING CMU & GYP. BD. ON FURRING ADD LAYER GYP. BD. ON FURRING OPP. SIDE
AutoCAD SHX Text
EXISTING CMU & GYP. BD. ON FURRING
AutoCAD SHX Text
CMU & GYP. BD. ON METAL FURRING
AutoCAD SHX Text
3-5/8" METAL STUDS 16" O.C. W/ 5/8" GYP. WALL BD. FIRE RATED
AutoCAD SHX Text
NEW CONC. WALK
AutoCAD SHX Text
EXISTING CONCRETE WALK
AutoCAD SHX Text
EXISTING GENERATOR
AutoCAD SHX Text
RELOCATE EYE WASH HERE
AutoCAD SHX Text
36"H. TYP
AutoCAD SHX Text
NEW CONCRETE WALK
AutoCAD SHX Text
NEW CONC. WALK
AutoCAD SHX Text
RELOCATE EYE WASH HERE
AutoCAD SHX Text
EXISTING CONCRETE WALK
AutoCAD SHX Text
EXISTING CMU & GYP. BD. ON FURRING
AutoCAD SHX Text
EXISTING CMU & GYP. BD. ON FURRING ADD LAYER GYP. BD. ON FURRING OPP. SIDE
AutoCAD SHX Text
EXISTING GYP. BD. ON METAL OR WOOD STUDS
AutoCAD SHX Text
REMOVE EXISTING CMU & GYP. BD. ON FURRING TO ACCOMMODATE NEW ADDITION AND PROVIDE NEW MASONRY LINTEL, BOTTOM AT 7'-4" A.F.F.
AutoCAD SHX Text
REMOVE EXISTING DOOR & FRAME
AutoCAD SHX Text
REMOVE EXISTING GYP. BD. ON METAL OR WOOD STUDS
AutoCAD SHX Text
REMOVE EXISTING WINDOW & SILL, FILL OPENING NEW CMU
AutoCAD SHX Text
REMOVE EXISTING EXTERIOR DOOR & INSTALL NEW INTERIOR DOOR TO MATCH EXISTING
AutoCAD SHX Text
RELOCATED EXISTING HVAC COMPRESSORS
AutoCAD SHX Text
REMOVE EXISTING CONC. SLABS & RELOCATE EYE WASH
AutoCAD SHX Text
RELOCATED EXISTING ELEC. PANEL
AutoCAD SHX Text
RELOCATED APPLICABLE EXISTING MILLWORK & APPLIANCES TO NEW BREAK ROOM
LOW LEVEL LED FLAT STRIP LIGHTING UNDERSIDE OF STEPS
AutoCAD SHX Text
EXISTING RECEPT (DUPLEX)
AutoCAD SHX Text
NEW RECEPT (DUPLEX)
AutoCAD SHX Text
RELOCATED EXISTING RECEPT (DUPLEX)
AutoCAD SHX Text
EXISTING WALL BOX, W/ BLANK COVER PLATE
AutoCAD SHX Text
EXISTING RECEPT (QUAD)
AutoCAD SHX Text
NEW DATA BOX & EMPTY CONDUIT STUBBED JUST ABOVE CEILING (WIRING & PLATES FOR DATA WILL BE PROVIDED BY OWNER)
AutoCAD SHX Text
MOVE
AutoCAD SHX Text
LIGHT FIXTURES TO BE REMOVED OR REUSE AT OTHER LOCATIONS
AutoCAD SHX Text
MOVE
AutoCAD SHX Text
MOVE
AutoCAD SHX Text
LIGHT FIXTURES TO BE REMOVED OR REUSE AT OTHER LOCATIONS
AutoCAD SHX Text
LIGHT FIXTURES TO BE RELOCATED AS INDICATED
AutoCAD SHX Text
LIGHT FIXTURES TO BE RELOCATED AS INDICATED
AutoCAD SHX Text
HVAC GRILLE TO BE RELOCATED AS INDICATED
AutoCAD SHX Text
MOVE
AutoCAD SHX Text
NEW LIGHT FIXTURES TO MATCH EXISTING
AutoCAD SHX Text
NEW LIGHT FIXTURES AS REQUIRED FOR STANDARD LIGHTING LEVELS
AutoCAD SHX Text
NEW LED STRIP LIGHTING FIXTURES AT UNDERSIDE OF OVERHEAD CABINETS
AutoCAD SHX Text
NOTE: DIMENSION SHALL BE COORDINATED WITH ACTUAL TRUSS LAYOUT. DISCREPANCIES SHALL BE RESOLVED WITH OWNER PRIOR TO INSTALLATION OF LIGHT FIXTURES, TYP.
AutoCAD SHX Text
NEW HVAC GRILLES, SEE DEMO PLAN FOR RELOCATED EXISTING GRILLES
AutoCAD SHX Text
A.ALL NEW CONSTRUCTION AND REMODELED AREAS, ALL NEW CONSTRUCTION AND REMODELED AREAS, INTERIOR AND EXTERIOR, SHALL MATCH EXISTING QUALITY OF MATERIALS, FINISHES, TEXTURES, BRANDS (IF POSSIBLE), ETC. ANY SUBSTITUTIONS FOR NON-MATCHING PRODUCTS SHALL BE APPROVED BY THE HCSO PROJECT MANAGER. B.NEW FLOORING SHALL MATCH EXISTING AS CLOSE AS NEW FLOORING SHALL MATCH EXISTING AS CLOSE AS POSSIBLE. IF NOT, THE FLOOR PATTERN DETAILS SHOWS THE PATTERN AT 45 DEGREES WITH BORDER WOOD STRIPS THAT CAN ACT AS AN ACCENT RATHER THAN EXACT MATCH. C.3D SKETCHES ARE PROVIDED OF THE NURSES AREA TO 3D SKETCHES ARE PROVIDED OF THE NURSES AREA TO HELP ILLUSTRATE MORE DETAIL OF THE AREA. THE MILLWORK SHALL BE COVERED IN PLASTIC LAMINATE. ALL MILLWORK SHALL HAVE LOCKS. D.SHELVING SHOWN IN THE MEDICAL ROOM SHALL BE SHELVING SHOWN IN THE MEDICAL ROOM SHALL BE WALL MOUNTED BRACKETS W/ ADJUSTABLE SHELF SUPPORTS AND WOOD SHELVING. E.COORDINATION WILL BE REQUIRED, ESPECIALLY WITH COORDINATION WILL BE REQUIRED, ESPECIALLY WITH EXISTING TRUSSES, FOR ANY PENETRATIONS REQUIRED IN THE EXISTING AND NEW CEILINGS.
WEST ELEVATION
EAST ELEVATION
NORTH ELEVATION
EXTERIOR ELEVATIONS
SCALE: 1/8" = 1'-0"
HILLSBOROUGH COUNTY
SHERIFF'S OFFICE
CHAD CHRONISTER, SHERIFF
P.O. BOX 3371
TAMPA, FLORIDA 33601
www.hcso.tampa.fl.us
PREPARED BY:
PROJECT PHASE:
DRAWN BY:
REVISIONS:
HILLSBOROUGH COUNTY SHERIFF'S OFFICE
GENERAL
SERVICES
FACILITIES
MAINTENANCE
UNIT
DESIGN
DEVELOPMENT
SHEET NAME:
SHEET NUMBER:
a.cordova
ISSUE DATE:
PROJECT:
ADDITION & RENOVATION TO:
OCCUPATIONAL
HEALTH
AND
WELLNESS
CLINIC
2214 N. FALKENBERG ROAD
TAMPA, FLORIDA 33619
02-20-2018
EXTERIOR ELEVATIONS
A-10.1
EXHIBIT - A
GENERAL NOTES
SHEET LIST:
A-2.1
A-2.15
A-2.2
A-5.1
A-5.2
A-10.1
AutoCAD SHX Text
A.ALL NEW CONSTRUCTION AND REMODELED AREAS, ALL NEW CONSTRUCTION AND REMODELED AREAS, INTERIOR AND EXTERIOR, SHALL MATCH EXISTING QUALITY OF MATERIALS, FINISHES, TEXTURES, BRANDS (IF POSSIBLE), ETC. ANY SUBSTITUTIONS FOR NON-MATCHING PRODUCTS SHALL BE APPROVED BY THE HCSO PROJECT MANAGER. B.COORDINATION WILL BE REQUIRED, ESPECIALLY WITH COORDINATION WILL BE REQUIRED, ESPECIALLY WITH EXISTING TRUSSES, FOR ANY PENETRATIONS REQUIRED IN THE EXISTING AND NEW CEILINGS.