remove existing culvert. - talco
TRANSCRIPT
101.70 x
CB
1
T/G
=101.40
21m
-400m
m Ø
C
SP
21m-4
50mm
Ø C
SP
150Ø
R
OO
F D
RA
IN
RM
M
150mm SANITARY CONNECTiON TO EXISTING
SANITARY MAIN STUB.
STUB INV. = 98.44
CITY OF OTTAWA STD. DETAIL W33. (REFER TO
NOTE 13 & 23)
RE
MO
VE
E
XIS
TIN
G
CU
LV
ER
T.
IN
V.=
99.03
IN
V.=
99.41
25.4m - 200Ø STM SEWER @ 1.0%
17.5m
- 150Ø
S
AN
S
EW
ER
@
1.0%
150Ø
R
OO
F D
RA
IN
EX
. C
BM
H 106
T/G
=
101.50
SW
IN
V.=
99.15
E IN
V.=
99.12
26.2m -200Ø STM SEWER @ 1.0%
SE
IN
V.=
99.00
W IN
V.=
99.06
1
4
.
9
m
-
3
0
0
Ø
S
T
M
S
E
W
E
R
@
0
.
4
%
EX. 1.5m - 300Ø
STM SEWER @
0.4%
EX
.S
TO
RM
CE
PT
OR
S
TC
750
EX. CBMH 101
T\G=101.48
SW INV.=98.90
NW INV.=98.84
SE INV.=98.82
NW INV.=98.88
NE INV.=98.82
31.0m
- 300Ø
S
TM
S
EW
ER
@
0.4%
N IN
V.=
99.05
SE
IN
V.=
99.11
9.3m
- 200Ø
S
TM
SE
WE
R @
1.0%
84.2 m
- 50 m
mØ
W
M T
YP
E K
1.0m - 150Ø STORM SEWER @
1.00%
0+10
0+00
0+
20
0+40
0+60
1+
10
1+
00
1+
20
STMH101 c/w HYDROVEX
MODEL ( 100SVHV-2)
0+
80
NE INV.=98.98
SW INV.=98.98
NW INV.=99.04
SE INV.=99.01
EX. 21.1m - 300Ø STM SEWER @ 0.34%
EX. 25.0m - 300Ø STM SEWER @ 0.65%
1
0
.
3
m
-
3
0
0
Ø
S
T
M
S
E
W
E
R
@
0
.
4
%
EX. STMH 101
T/G = 101.52
ST
MH
102
T\G
=101.68
EX. CBMH 102
T\G=101.50
NE
IN
V.=
98.98
SW
IN
V.=
99.01
7.1m - 300Ø STM
SEWER @ 0.4%
5.1m - 300Ø STM
SEWER @
0.4%
CB
MH
103
T\G
=101.45
IN
V.=
98.95
CB
MH
108
T\G
=101.48
CB
3
T/G
=101.48
IN
V.=
99.20
INLET INV=98.80
OUTLET INV=100.50
OUTLET OVERFLOW INV=101.00
(FOR PUMP STATION DETAILS REFER TO DWG. DT1)
EX. DUPLEX FIBERGLASS PUMP STATION
T/G=101.80
EX. 2.8m - 300Ø STM
SEWER @ 0.4%
DIT
CH
E
LE
V.=
100.42
31.0m - 38mm Ø WM
TYPE K
1+
30
11.3m
-150m
Ø
S
TM
SE
WE
R @
1.0%
DC
D
C
3 X
50m
m P
VC
C
ON
DU
IT
F
OR
P
OW
ER
C
ON
TR
OL
CA
BLE
S
PR
OP
OS
ED
P
UM
PS
C
ON
TR
OL
PA
NE
L DC
DC
EX. 3.3m - 300Ø
STM SEWER @
4.5%
EX .CBMH 104
T\G=101.50
SWINV.=99.29
NE INV.=99.26
NE INV.= 99.14
SW INV. = 99.19
37.9m - 150 Ø SAN SEWER
@ 1.0%
EX. CBMH 105
T\G=101.54
NW INV= 98.62
E INV = 98.65
SE INV = 98.65
SW INV. = 98.88
EX. SANMH 101
T\G=101.44
14.2m - 150 Ø SAN SEWER @ 1.0%
IN
V.=
98.79
CE
NT
ER
LIN
E O
F R
EA
LIG
NE
D D
IT
CH
PR
OP
OS
ED
D
IT
CH
1
3
.5
m
-
4
0
0
m
m
Ø
C
S
P
A
S
P
H
A
LT
S
ID
E
W
A
LK
CO
NC
RE
TE
SID
EW
ALK
D
C
D
C
DC
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
///
///
////
///
///
////
///
///
////
///
///
////
///
///
////
///
///
////
/////
////
///
///
/////
///
//
// /
/ /
MR
/ / / / /
/ / / / /
/ / / / /
/ / / / / / / / / / / / / / // / / / /
// /
/ /
±7
.0
ALL CONSTRUCTION
TRAFFIC TO CROSS
MUD MAT WHEN
EXITING THE SITE
RIPRAP STONE
(100mm TO 150mm
SIZE TWO LAYERS
THICK)
50mm CLEAR LIMESTONE
ACCESS ROAD AS
REQUIRED UP TO EX.
ROAD PAVEMENT
±5.0m
PROVIDE GEOTEXTILE
FILTER CLOTH PRIOR
TO PLACING RIPRAP
MATERIAL
NOT VALID UNLESS SIGNED AND DATED
PROJECT NO.
1015105
DESIGNED BY: APPROVED BY:DRAWN BY:
CLIENT
I.J. D.G. I.J.
ENTERPRISE HOLDINGS
2300 STEVENAGE DR.
OTTAWA, ON K1G 3W3
T: (613) 274-6945
DRAWING TITLE
PROJECT
ENTERPRISE
225 HUNTMAR DRIVE
OTTAWA, ON K2S 1B9
GENERAL NOTES:
THE ENGINEER WAIVES ANY AND ALL RESPONSIBILITY AND
LIABILITY FOR PROBLEMS WHICH ARISE FROM FAILURE TO
FOLLOW THE PLANS, SPECIFICATIONS AND THE DESIGN INTENT
THEY CONVEY, OR FOR PROBLEMS WHICH ARISE FROM
OTHERS' FAILURE TO OBTAIN AND/OR FOLLOW THE ENGINEER'S
GUIDANCE WITH RESPECT TO ANY ERRORS, OMISSIONS,
INCONSISTENCIES AMBIGUITIES OR CONFLICTS WHICH ARE
ALLEGED.
CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY THE
ENGINEER OF ANY DISCREPANCIES BEFORE WORK
COMMENCES. DO NOT SCALE DRAWINGS.
www.mmm.caf: 613.736.8710t: 613.736.7200
Ottawa, ON Canada K1V 0Y31145 Hunt Club Dr.
V:\10-40 M
unicipal Infrastructure\1015105 - E
nterprise R
ent A
C
ar\3. D
raw
ings\W
orking D
raw
ing\1015105 - E
ngineering plans.dw
g
Nov 04, 2019 - 12:52pm
, caw
y069741
FILE
NA
ME
:
PLO
TD
AT
E:
01 ISSUED FOR SPA I.J.APRIL 22, 2016
BYNo. REVISIONS DATE
DISTANCES SHOWN ON THIS PLAN ARE IN METRES AND CAN BE
CONVERTED TO FEET BY DIVIDING BY 0.3048
D07-12-16-0066
DWG. NO.
02
ISSUED AS PER CITY
COMMENTS
I.J.SEPT 30, 2016
03
ISSUED AS PER CITY
COMMENTS
I.J.JAN 18, 2017
I. M. JAFFERJEE
100164153
2019-11-04
04
ISSUED AS PER CITY
COMMENTS
I.J.MARCH 10, 2017
05
ISSUED AS PER CITY
COMMENTS
I.J.APRIL 20, 2017
06 I.J.NOV 04, 2019
ISSUED FOR TENDER
EROSION & SEDIMENT CONTROL AND
GRADING & DRAINAGE PLAN
C.02
05m 2 5m
SCALE: 1:200
KEY PLAN
(N.T.S)
HORIZONTAL SCALE: