AFPELEVATOR-Omega64 Datasheet 1 | Page OMEGA 64 Microprocessor Elevator Control Panel www.afpelevator.com Data Sheet Version 89.1 (Software: AFP141) Manufacture by: AFP AFP AFP AFP ELEVATOR CO. Registered To: ISO9001: 2000 By:

Upload: hadien

Post on 10-May-2018

264 views

Category:

Documents


16 download

TRANSCRIPT

Page 1: Omega 64 - AFP Elevator · OMEGA 64 Microprocessor Elevator Control ... • Hardware connection through the RS232 & RS485 by means of MOD BUS ... GSM Modem, VVVF DRIVES,

AFPELEVATOR-Omega64 Datasheet

1 | P a g e

OMEGA 64

Microprocessor Elevator Control Panel

www.afpelevator.com

Data Sheet Version 89.1

(Software: AFP141)

Manufacture by:

AFPAFPAFPAFP ELEVATOR CO.

Registered To: ISO9001: 2000

By:

Page 2: Omega 64 - AFP Elevator · OMEGA 64 Microprocessor Elevator Control ... • Hardware connection through the RS232 & RS485 by means of MOD BUS ... GSM Modem, VVVF DRIVES,

AFPELEVATOR-Omega64 Datasheet

2 | P a g e

Page 3: Omega 64 - AFP Elevator · OMEGA 64 Microprocessor Elevator Control ... • Hardware connection through the RS232 & RS485 by means of MOD BUS ... GSM Modem, VVVF DRIVES,

AFPELEVATOR

OMEGA 64

Omega64 has been designed as the mai

the elevator system. This Micro-up to 32 stops is equipped with parallel connection with the hall buttons and has

two separate serial connections too.

Omega 64 connections:

1 – Serial Connection to Car Codec (CAR: Terminals BXC & AXC connect to terminals AX & BX on the Car

2 – Parallel Connection to the Hall Buttons by two means

AFPELEVATOR-Omega64 Datasheet

has been designed as the main board of control panel to co

-controller which is capable of servicing elevators is equipped with parallel connection with the hall buttons and has

two separate serial connections too.

Codec (CAR-16B) BXC & AXC connect to terminals AX & BX on the Car Codec

Parallel Connection to the Hall Buttons by two means

3 | P a g e

to commanding

is capable of servicing elevators is equipped with parallel connection with the hall buttons and has

Codec

Page 4: Omega 64 - AFP Elevator · OMEGA 64 Microprocessor Elevator Control ... • Hardware connection through the RS232 & RS485 by means of MOD BUS ... GSM Modem, VVVF DRIVES,

AFPELEVATOR-Omega64 Datasheet

4 | P a g e

Related modules with Omega 64:

• Car Codec system for reducing the cabin wiring length(CAR-16B)

• Omega 64 Extension Board(Omega-EXT-V3)

• Hall Codec system for reducing the hall wiring length(S panel)

• Voice enunciator Board (TETA32 – V2)

Note:

� Car Codec must be installed together with Omega64 at all times…

� In three case, Omega-EXT is used: ���� Selective-Collective maneuver lower than 16 floors(1 piece)

���� Selective-Collective maneuver upper than 16 floors(3 Pieces) ���� Down-Collective maneuver upper than 16 floors(1 piece)

This board is connected through the MODBUS with Omega-64…

Page 5: Omega 64 - AFP Elevator · OMEGA 64 Microprocessor Elevator Control ... • Hardware connection through the RS232 & RS485 by means of MOD BUS ... GSM Modem, VVVF DRIVES,

AFPELEVATOR-Omega64 Datasheet

5 | P a g e

Omega64 Features:

• Ability to service up to 32 stops both in serial and parallel modes, Simplex & Duplex control

• Powerful software and full programmable to control different Lifts.

• Virtual movement control in Normal mode & Programmable to work without Car Codec Board at the initial install mode(Inspection mode)

• Produced with SMD Technology

• Compatible with EN-81 Standard

• Hardware connection through the RS232 & RS485 by means of MOD BUS Protocol

• RS232: for monitoring the elevator situation including inputs request, outputs, Cabin …

• RS485: Serial hardware connection by means of BXC & AXC terminals to cabin and BXH & AXH terminals to Hall Codec

• MODBUS: serial communication with other equipments like Access control , GSM Modem, VVVF DRIVES, Hall codec

Page 6: Omega 64 - AFP Elevator · OMEGA 64 Microprocessor Elevator Control ... • Hardware connection through the RS232 & RS485 by means of MOD BUS ... GSM Modem, VVVF DRIVES,

AFPELEVATOR-Omega64 Datasheet

6 | P a g e

• Ability to record and display 100 Error messages along with exact time of Error occurrence

• Equipped with short-circuit protection for the indicator

• Adapted to work with different kind of LCDs with language selection manually • Capable to show the status of door locks and door contacts in case of using of

Spanel. • Accelerated calculation speed through powerful micro-controller

• Expandable software with Fire floor determining

• Equipped with protection system for operation under 5V • Capable to situate the cabin by means of shaft encoder

• Ability to indicate the cabin inputs status

• Equipped with two digit 7-Segment to show all characters

• To raise safety, the contactors are commanded through relays

• Equipped with clock IC and backup batteries to calculate time and date

• Ability to display correct connection between two control panels in Duplex and correct connection to car codec system

• Equipped with 3 programmable relays for especial cases like: Hoist way lighting and Y-transformation in Hydraulic controllers

LEF LED,…, , CONNECTION LED

Page 7: Omega 64 - AFP Elevator · OMEGA 64 Microprocessor Elevator Control ... • Hardware connection through the RS232 & RS485 by means of MOD BUS ... GSM Modem, VVVF DRIVES,

AFPELEVATOR-Omega64 Datasheet

7 | P a g e

Installation Diagram:

This map is shows how is the

Omega 64 structure is work…

Main board Features:

•••• Ability to control all types of lifts :2-speed,hydraulic & VVVF systems

•••• Powerful software and

full programmable & monitoring by PC

•••• The new word technology design.

•••• Ability to simplex and Groups control

•••• Serial communications for cabin and hall by RS485

•••• Compatible with all of high accuracy Encoders through the program menu

•••• Ability to display Doors and locks status for each floor.

Page 8: Omega 64 - AFP Elevator · OMEGA 64 Microprocessor Elevator Control ... • Hardware connection through the RS232 & RS485 by means of MOD BUS ... GSM Modem, VVVF DRIVES,

AFPELEVATOR-Omega64 Datasheet

8 | P a g e

CAR CODEC System

MODEL: CAR-16 B

This system is designed to diminish the number of traveling cables in the hoist way. Thus making data transfer from the car to controllers more feasible. Features:

Powerful software for preventing errors caused by noise.

Data transfer through RS485 system between car & controller. Compatible with two kind of controllers: Omega64, EC-16

Full SMD production Installed inside the terminal Box

Show of input, output & floor position.

Simplifies quick installation upper than 16 floors.

Reducing time & cost Trouble shooting in high buildings.

Page 9: Omega 64 - AFP Elevator · OMEGA 64 Microprocessor Elevator Control ... • Hardware connection through the RS232 & RS485 by means of MOD BUS ... GSM Modem, VVVF DRIVES,

AFPELEVATOR

TETA 32-V2

This board is marketed under the commercial name TETA32 – V2. The Enunciator Board TETA32 –announce floor numbers and play music while the cabin

is in motion.

Features:

•••• Equipped with flash memory with

AFPELEVATOR-Omega64 Datasheet

This board is marketed under the commercial name

– V2 is designed to announce floor numbers and play music while the cabin

Equipped with flash memory with 4 MB of memory

9 | P a g e

Page 10: Omega 64 - AFP Elevator · OMEGA 64 Microprocessor Elevator Control ... • Hardware connection through the RS232 & RS485 by means of MOD BUS ... GSM Modem, VVVF DRIVES,

AFPELEVATOR-Omega64 Datasheet

10 | P a g e

•••• Capable of playing eight pieces of music with 20

second length and in frequency of 11.025Khz

•••• Capable of communicating with Car Codec through MODBUS

•••• Small size and SMD production

•••• Possibility to change the music & announcement files simplify

•••• Horizontal installation on Car Codec

Connect to Car codec system through the 2 *6 pin header

Voice Enunciator board

TETA 32-V2

Page 11: Omega 64 - AFP Elevator · OMEGA 64 Microprocessor Elevator Control ... • Hardware connection through the RS232 & RS485 by means of MOD BUS ... GSM Modem, VVVF DRIVES,

AFPELEVATOR-Omega64 Datasheet

11 | P a g e

SPANEL (Serial Panel):

Spanel Board is used to reduce wire connection number with Hall Buttons. This

board is connected to the control panel through the cable network CAT5 or CAT6.

Once the hall button is pressed, the micro controller recognizes the signal and sends the floor information to Omega64.

The technical name for this board is Delta7 and we have chosen Spanel as the

commercial name for it.

Features:

•••• Capable to service between 2 to 32 floors

•••• Serial communication with Omega64 through RJ45 terminals

•••• Equipped with one or two digit 7Segment and two displays to show the the position and the direction the cabin is moving in.

•••• Capable to connect to Collective-Selective buttons

•••• Equipped with the Fire Floor Input & thermometer

Page 12: Omega 64 - AFP Elevator · OMEGA 64 Microprocessor Elevator Control ... • Hardware connection through the RS232 & RS485 by means of MOD BUS ... GSM Modem, VVVF DRIVES,

AFPELEVATOR-Omega64 Datasheet

12 | P a g e

•••• Designed in 3 models:

���� Spanel with one 7-Segments display (Two Button)

���� Spanel with two 7-Segments display (Two Buttons)

���� Spanel with Graphic LCD display (Two Buttons)

•••• Capable to be produced in one or two digits or Graphic LCD…

(One Digit) Display -9 to 9

(Two Digit)

Display -9 to 99

Page 13: Omega 64 - AFP Elevator · OMEGA 64 Microprocessor Elevator Control ... • Hardware connection through the RS232 & RS485 by means of MOD BUS ... GSM Modem, VVVF DRIVES,

AFPELEVATOR-Omega64 Datasheet

13 | P a g e

Spanel Connection Map:

The Serial Panel connection method as shown here…

Features:

•••• Capable to service between 2 to 32 floors

•••• Serial communication with Omega64

through CAT5 or CAT6 by RJ45 terminal

•••• Equipped with one or two digit 7Segment

and two displays to show the the position and the direction the cabin is moving in.

•••• Equipped with the Fire Floor Input & thermometer.

•••• Capable to connect to

Collective-Selective buttons

•••• Designed in 3 models ���� 1 Digit -Two Buttons ���� 2 Digit -Two Buttons ���� Graphic LCD Display

For the first landing floor, it must be put the Node jumper on

the Spanel board

Spanel on the First floor

Spanel on Nth floor

Page 14: Omega 64 - AFP Elevator · OMEGA 64 Microprocessor Elevator Control ... • Hardware connection through the RS232 & RS485 by means of MOD BUS ... GSM Modem, VVVF DRIVES,

AFPELEVATOR-Omega64 Datasheet

14 | P a g e

Spanel installation In the Single Button panel:

• To connect the Spanel to Omega64, connect the terminal RJ45 from omega

64 to the same corresponding terminal on the Spanel. This is used by means

of ModBus Technology through the CAT5 or CAT6 Cable.

• At the lowest landing floor it must be set the special jumper (Node) on the

Spanel board.

Serial panel board in Panel Back view

Panel Front view

Jumper (Node)