omf010003 power control issue1.5

50
www.huawei.com Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Power Control

Upload: laurochi

Post on 23-Oct-2014

110 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: OMF010003 Power Control ISSUE1.5

www.huawei.com

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Power Control

Page 2: OMF010003 Power Control ISSUE1.5

Page2Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Contents

1. Power Control Overview

2. HWⅠPower Control

3. HWⅡPower Control

Page 3: OMF010003 Power Control ISSUE1.5

Page3Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Power Control Overview

Power control

Adjust the transmitting power of BTS and MS when

needed.

Based on measurement reports of BTS and MS

Purpose

Save the power of BTS and MS

Reduce the interference of the network

Increase the quality of the network

Page 4: OMF010003 Power Control ISSUE1.5

Page4Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Power Control Overview Power control includes uplink power control and

downlink power control, Which are performed

independently

Uplink power control: Adjust TX power of MS to let BTS

receive stable signal, reduce the uplink co-channel and

adjacent channel interference, reduce power consumption

of MS

Downlink power control: Adjust BTS TX power to let MS

receive stable signal, reduce the downlink co-channel and

adjacent channel interference, reduce power consumption

of BTS

Page 5: OMF010003 Power Control ISSUE1.5

Page5Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Power Control Overview

Process of power control commands

It takes 3 measurement report periods(480ms/period)

from command sending to execution.

SA0 SA1SA0 SA0SA1SA1 SA2SA2SA2 SA3SA3SA3

BTS sends the command for power control and TA in SACCH header.

MS obtains SACCH block

MS begins to send the measurement report of the last multi-frame.

In the 26 multi-frames, frame 12 sends SACCH.

BTS receives the measurement report

SACCCH report period: 26X4=104 frames (480ms)

MS adopts the new power level and TA

MS begins to set up a new SACCH header to report the new TA and power control message.

Page 6: OMF010003 Power Control ISSUE1.5

Page6Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Power Control Overview

Huawei power control algorithm: HW I and HW II power control

Measurement report pre-processing

Power control

algorithm selection

HW I power control

algorithm

HW II power control

algorithm

GSM0508 power control

algorithm

Page 7: OMF010003 Power Control ISSUE1.5

Page7Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Power Control Overview Power control judgment and the selection of HWI algorithm or

HWII algorithm

Power control algorithm selected in power control data table

Power control judgment is controlled by BTS measurement report

pre-processing item which can be selected in handover control

data table

MR. Pre-process (measurement report pre-processing): This switch

decide where power control be processed. If measurement report

pre-processing is “yes”, power control is processed in BTS, and

when setting it “no”, power control is processed in BSC

Page 8: OMF010003 Power Control ISSUE1.5

Page8Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Contents

1. Power Control Overview

2. HWⅠPower Control

3. HWⅡPower Control

Page 9: OMF010003 Power Control ISSUE1.5

Page9Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW I Power Control

HW I power control

Process of HW I power control

MR pre-processing

Data configuration for HW I power control

Comparison of uplink power control with downlink power

control

Page 10: OMF010003 Power Control ISSUE1.5

Page10Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Process of HW I power control

Measurement report pre-processing

Aim achieved

Power control calculation and adjustment

N

Y

HW I Power ControlHW I Power Control

Page 11: OMF010003 Power Control ISSUE1.5

Page11Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Original data of power control -- measurement report

Network

Downlink Downlink measurement measurement

reportreport

Uplink MRUplink MR

BTS

HW I Power ControlHW I Power Control

Page 12: OMF010003 Power Control ISSUE1.5

Page12Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Uplink Uplink measurement measurement

reportreport

Downlink Downlink measurement measurement

reportreport

HW I Power ControlHW I Power Control Measurement report

Page 13: OMF010003 Power Control ISSUE1.5

Page13Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Measurement report pre-processing -- interpolation

Each measurement report has a serial number. When the serial

numbers are discontinuous, this indicates that some

measurement reports must be missed. In this case, the network

will fill up the measurement report according to interpolation

algorithm.

MR MR MR MR MR

Measurement report serial number n

Measurement report serial number n+4

Consecutive measurement report flow

3 missing measurement reports3 missing measurement reports

HW I Power ControlHW I Power Control

Page 14: OMF010003 Power Control ISSUE1.5

Page14Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Measurement report pre-processing -- filtering

Calculate average results of several consecutive

measurement reports to obtain the current

information, reduce the influence of some abnormal

measurement reports for the judgment of power

control.

MR MR

MR

MR

MR MR

Consecutive measurement report flow

FilterFilter

HW I Power ControlHW I Power Control

Page 15: OMF010003 Power Control ISSUE1.5

Page15Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW I power control judgment (Stable adjustment stage)

Transmitting power adjustment =

(expected stable uplink or downlink RXLEV – actual uplink or

downlink RXLEV) * uplink or downlink RXLEV compensation

factor + (actual uplink or downlink RXQUAL - expected uplink or

downlink RXQUAL)*10* uplink or downlink quality compensation

factor

The final adjustment power level should not exceed the

maximum power control step size

Final stable level = current level + transmitting power

adjustment

HW I Power ControlHW I Power Control

Page 16: OMF010003 Power Control ISSUE1.5

Page16Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW I Power Control

HW I power control judgment (Initial adjustment stage) Transmitting power adjustment = (actual initial RXLEV – expec

ted initial RXLEV) * uplink RXLEV compensation factor

Final transmitting power = initial RXLEV – transmitting power adjustment

If the RXLEV lower than the expected initial RXLEV, power control will not occur within initial adjustment stage

Page 17: OMF010003 Power Control ISSUE1.5

Page17Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

[BTS power control table][BTS power control table]

HW I Power Control Configuration HW I power control data configuration and parameter

introduction

Parameter name

Meaning Value range

Recommended value

DL RX_LEV Expected

The expected signal level of MS in stable status, Expected stable downlink signal level > downlink edge HO threshold,Otherwise, ping-pang HO will be caused.

0~63 (-110 dBm– -47 dBm)

35

DL RX_LEV Compensati

on

The power adjustment value varies with this parameter. The adjustment value caused by power level equal to the difference between the expected signal level and the actual receiving signal level multiply this factor.

0~100%

80% (signal ex-signal

rx)*80%=adjustment value

DL Qual. Expected

Expected signal quality of MS in stable status. 0~7

Levels 1

DL Qual.Comp

ensation

The power adjustment value varies with this parameter. The adjustment value caused by signal quality equal to 10*difference between the expected signal quality level and the actual receiving signal quality level multiply this factor.

0~100%

20% [10*(quality RX-quality EX)*20%]

MAX PC Step

Maximum adjustment range in one BTS power control command

Levels 0~16,

2dB each step

8

Page 18: OMF010003 Power Control ISSUE1.5

Page18Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW I Power Control Configuration[BTS power control table][BTS power control table]

Parameter name

Meaning Value range Recommended

value BTS PC Period

Time interval for implementing two power control commands (unit count of SACCH period)

1~10 5

Filter length for DL

RX_LEV

Content: indicating the number of measurement reports in which the average of uplink signal strength is taken before MS power adjustment at stable stage. The purpose is to remove the influence of some abnormal reports. When the filter length is too long, the influence due to abnormal reports will be weakened, but the MS power adjustment is not timely.

1~32 5

BTS Min Tx power

Indicating the minimum transmitting power allowed by the base station. No matter what the original base station power is, how many levels it can be down-tuned, the transmitting power of the base station cannot be lower than this value.

0~36dBm 4

PC Adj. Range

Indicating the maximum level the base station dynamic power can be adjusted

1~16, corresponding

to 0~30dB 16

Page 19: OMF010003 Power Control ISSUE1.5

Page19Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

[MS power control data table][MS power control data table]

HW I Power Control Configuration

Parameter name

Meaning Value range Recom-mended

value Initial

RX_LEV expected

The expected BTS receiving signal level in the initial stage when MS access the network. 0~63

(-110 dBm – -47 dBm) 30

Stable EX_LEV Expected

The expected BTS receiving signal level in stable status. Expected stable signal level > uplink margin HO threshold (HO parameter). Otherwise, “ping-pang” HO will be caused.

0~63 (-110 dBm – -47 dBm) 30

UL RX_LEV compensati

on

Give an adjustment for the power control level value, the actual power level value MS should change is the result of this parameter multiply the difference between the expected uplink signal level and the actual BTS receiving signal level.

0~100% 80%

UL Qual. Expected

The expected BTS receiving signal quality in stable status.

UL Qual. compensat

ion

The power adjustment value varies with this parameter. The adjustment value caused by signal quality equal to 10*difference between the expected signal quality level and the actual receiving signal quality level times this factor.

0~100% 20%

Max PC step

The maximum level of MS power that can be dynamically adjusted.

Level 1~16, 2dB/level.

8

Page 20: OMF010003 Power Control ISSUE1.5

Page20Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Parameter name Meaning Value

range Value recommended

PC interval Time interval between the implementations of two power control algorithms; unit: SACCH period

0~30 5

Filter length for Initial RX_LEV

This is the number of measurement reports required for predicting the signal strength at the initial stage. Unit: Measurement reports

1~32 2

Filter length for stable RX_LEV

This is the number of measurement reports required for predicting the signal strength at the stable power control stage. Unit: Measurement reports

1-31 5

Filter length for Qual.

This is the number of the measurement reports required for assessing signal quality at the stable stage. Unit: Number of measurement reports

1~30 6

[MS power control table][MS power control table]

HW I Power Control ConfigurationHW I Power Control Configuration

Page 21: OMF010003 Power Control ISSUE1.5

Page21Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW I Power Control

Power control will not occur in case of these four

conditions

Both level and quality equal to the setting values (HW I

power control), or level and quality are within threshold

band(HW II power control)

Adjusting range for MS less than error tolerance

Adjusting range less than minimum power control step of BTS

The RXLEV lower than the expected initial RXLEV within initial

adjustment stage

Page 22: OMF010003 Power Control ISSUE1.5

Page22Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW I Power Control HW I power control judgment

Before judging the signal level to be adjusted, query the error

tolerance table according to the current transmitting power

level. Adjustment will not be done if the power adjustment

value is less than the error tolerance value.

Error tolerance table for 900M and 1800M is as follows:1800M:

Level 0 1 2 3 4 5 6 7 8 9 10 11

12 13 14

15 16

17 18

19

Error tolerance

2 2 2 2 2 2 2 2 2 3 3 3 3 3 4 4 4 2 2 2

900M:

Level 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

17 18

19

Error tolerance

2 2 2 4 4 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6

Page 23: OMF010003 Power Control ISSUE1.5

Page23Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW I Power Control

Comparison uplink and downlink of HW I power control .

Similarity:

1. To avoid frequently changes of signal level, the PC interval time

between the two consecutive uplink and downlink power control

are limited.

2. To reduce the influence caused by abnormal reports, all

measurement reports should be filtered.

3. Both uplink and downlink power controls include level-specific

and quality-specific power controls.

4. Both uplink and downlink power controls have maximum power

control step size limit and compensating factor.

Page 24: OMF010003 Power Control ISSUE1.5

Page24Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Comparison uplink and downlink of HW I power control .

Differentia:

1. Including power control for the stable stage, MS also has

power control when MS access the network, thus to reduce

transmitting power of MS as soon as possible.

2. For uplink, precautions are ready for increase MS

transmitting power in case HO fails.

3. For downlink, there are maximum and minimum

transmitting power limits in power control data configuration.

4. MS has the error tolerance table.

HW I Power ControlHW I Power Control

Page 25: OMF010003 Power Control ISSUE1.5

Page25Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW I power control exercise Given conditions:

900M MS transmitting at the maximum power, uplink receiving level of the 900M BTS is –60dBm, uplink quality level is always 0.

Parameter configuration in [BTS power/MS power control table] is as follows – “stable RX_LEV Expected” is 35, “UL RX_LEV Compensation” is 80, “UL Qual. expected ” is 1, and “UL Qual. compensation” is 20, and the max. PC step is 16dB.

HW I Power ControlHW I Power Control

Page 26: OMF010003 Power Control ISSUE1.5

Page26Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW I power control exercise

Question:

1. Suppose that power control will no longer be done once

the power value to be adjusted is less than 2dB, what is

the approximate stable power value after power control

with the above data configuration?

2. According to the error tolerance list, suppose the initial

MS transmitting power is level 3, what is the maximum

uplink receiving level in stable status after power control?

ExerciseExercise

Page 27: OMF010003 Power Control ISSUE1.5

Page27Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW I power control exercise

Answers for question 1: Stable level = current actual level + [(expected signal intensity in stable statu

s – current actual level) * uplink path loss compensating factor] + [actual current quality – expected uplink signal quality) * 10 * uplink quality compensating factor] = -60+[(-75-(-60))*80 % ]+[(0-1)*10*20 % ] = -60-12-2 = -74dBm. Now it’s necessary to adjust -14dB (no larger than the maximum power control step size), but it needs further adjustment because it fails to reach -75dBm, the “expected signal level in stable status”. Use -74 in the above formula again for calculation, and the power to be adjusted is -2.8dB. Because no power control adjustment will be done when the power value to be adjusted is smaller than -2, it still needs to be changed 2dB lower, so the uplink receiving level is -76dBm at last.

ExerciseExercise

Page 28: OMF010003 Power Control ISSUE1.5

Page28Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Answers for question 2:

Query the error tolerance table, the tolerance of level 3 is

4dB, the power to be adjusted for the second time is 2.8,

which is less than 4 and up to the requirement, so the

final uplink receiving level is -74dBm in stable status.

ExerciseExercise

Page 29: OMF010003 Power Control ISSUE1.5

Page29Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Contents

1. Power Control Overview

2. HWⅠPower Control

3. HWⅡPower Control

Page 30: OMF010003 Power Control ISSUE1.5

Page30Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW II Power Control

Power control judgment process

Measurement report pre-processing

The power control demand according to the

receiving level

Send the power control command

The power control demand according to receiving quality

General power control judgement

Page 31: OMF010003 Power Control ISSUE1.5

Page31Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW II Power Control Measurement report compensation

Purpose: Ensure the accuracy of selection of the history measurement report before filtering.

Implementation steps: 1. Put the current receiving measurement report into the

measurement report compensation queue.

2. Record the changed information of the transmitting power according to the MS and BTS power levels in the measurement report.

3. After finish the measurement report interpolation, system will compensate the receiving level of the history measurement report according to the power change information. The compensated measurement reports will be the original data in the filter process.

4. Filter the compensated measurement reports.

Page 32: OMF010003 Power Control ISSUE1.5

Page32Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW II Power Control Measurement report compensation

The expected receiving signal level: 30

The power control will be more effective with measurement report compensation.

The expected receiving signal level: 30

The power control will be more effective with measurement report compensation.

X axis

1 2 3 4 5 6 7 8 910

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

500

10

20

30

40

50

60

70

Y a

xis

Power control diagram when there is measurement report compensation

Diagram when there is no power control

Power control diagram when there is no measurement report compensation

Power control effect diagram of measurement report compensation

Page 33: OMF010003 Power Control ISSUE1.5

Page33Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW II Power Control Measurement report prediction

Purpose: Avoid power control later than needed, the delay

is dangerous in case of poor level or bad quality

Implementation procedure

1. Analyze the tendency of MR by the historical measurement

reports after interpolation.

2. Guide by the tendency, to predict the values of

measurement report to be received. There are 0~3

measurement reports prediction, which are configured on

OMC.

3. Filter the interpolated, compensated and predicted

measurement reports, and implement power control judgment.

Page 34: OMF010003 Power Control ISSUE1.5

Page34Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW II Power Control Measurement report prediction

1 2 3 4 5 6 7 8 910

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

X axis

15

20

25

30

35

40

45

50

Y a

xis

No power control

Mean filter power control

Prediction filter power control

Diagram of power control effect comparison between prediction filter and mean filter

The expected receiving signal level: 30

The power control with prediction filter will be more effective than that with mean filter

The expected receiving signal level: 30

The power control with prediction filter will be more effective than that with mean filter

Page 35: OMF010003 Power Control ISSUE1.5

Page35Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW II Power Control Implementation Power control demand based on receiving level.

After measurement report pre-processing, the power

control module makes a comparison between the expected

signal level and the current receiving signal level.

Calculate the transmitting power level step size to be

adjusted, making the receiving level value closer to the

expected value.

Adopt variable step size when adjusting the transmitting

power according to the receiving level, so as to achieve the

expected level as soon as possible.

Page 36: OMF010003 Power Control ISSUE1.5

Page36Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW II Power Control Implementation Power control demand based on receiving quality

After measurement report pre-processing, the power control

module makes comparison between the expected quality level

and the current receiving quality level.

Calculate the step size of the transmitting power level to be

adjusted.

Increase the transmitting power in case of poor receiving quality.

Decrease the transmitting power in case of good receiving quality.

Adopt fixed step size when adjust the transmitting power

according to the receiving quality.

Page 37: OMF010003 Power Control ISSUE1.5

Page37Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW II Power Control Implementation General power control judgment

Power control by receiving

level

Power control by receiving

quality

Power control by signal level and

quality

↓ AdjStep_Lev ↓ AdjStep_Qul ↓ max(AdjStep_Lev,AdjStep_Qul)

↓ AdjStep_Lev ↑ AdjStep_Qul No action

↓ AdjStep_Lev No action ↓ AdjStep_Lev

↑ AdjStep_Lev ↓ AdjStep_Qul ↑ AdjStep_Lev

↑ AdjStep_Lev ↑ AdjStep_Qul ↑ max(AdjStep_Lev,AdjStep_Qul)

↑ AdjStep_Lev No action ↑ AdjStep_Lev

No action ↓ AdjStep_Qul ↓ AdjStep_A

No action ↑ AdjStep_Qul ↑ AdjStep_B

No action No action No action

Page 38: OMF010003 Power Control ISSUE1.5

Page38Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW II Power Control Feature Adaptive power control:

Adaptive power control refers to changeable power control

strategy according to the communication environment, it

makes power control more effective and stable.

Automatically change the adjustable maximum step size of

power control according to different communication

environment (different receiving quality).

Adopt different power control strategies according to different

communication environments (different receiving quality and

level).

Max. step is different between increase and decrease.

Page 39: OMF010003 Power Control ISSUE1.5

Page39Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW II Power Control Feature

Power control within the upper/lower thresholds

As for HW II power control in case of calculating power

control step size according to signal level and quality, the

signal level and quality have upper/lower thresholds.

Power control will not execute if the signal level and

quality is within the threshold bands.

Avoid the signal level up-and-down caused by power

control.

The upper threshold can be increased dynamically in case

of bad quality.

Page 40: OMF010003 Power Control ISSUE1.5

Page40Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Measurement report compensation -- makes power

control judgment more accurate

Measurement report prediction --to avoid power

control later than needed, the delay is dangerous in

case of poor level or bad quality

Power control expected signal level and quality

threshold falls within a band, this avoids receiving

signal level fluctuate up and down frequently

HW II Power Control Advantages

Page 41: OMF010003 Power Control ISSUE1.5

Page41Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW II Power Control Configuration[HW II power control table] main parameters – 1 [HW II power control table] main parameters – 1

Parameter name

Meaning Value range

Recommended value

filter length for UL

RX_LEV

How many uplink measurement reports obtained for the average uplink signal level to be used for uplink power control adjustment.

1~20 6

filter length for DL

RX_LEV

How many downlink measurement reports obtained for the average downlink signal level to be used for downlink power control adjustment.

1~20 6

filter length for UL Qual.

How many uplink measurement reports obtained for the average uplink quality level to be used for uplink power control adjustment.

1~20 6

filter length for DL Qual.

How many downlink measurement reports obtained for the average downlink quality level to be used for downlink power control adjustment.

1~20 6

MR compensation

allowed

If “yes”, System put the currently received measurement report into the measurement report compensation queue, and record the transmitting power information according to MS and BTS power values. And then interpolation, compensate the receiving level value of the record measurement report according to the power change information.

Yes, no Yes

UL MR number

predicted

The number of uplink pred. MR in the filter using for power control judgment.

0~3 reports

2

DL MR number

predicted

The number of downlink pred. MR in the filter using for power control judgment.

0~3 reports

2

Page 42: OMF010003 Power Control ISSUE1.5

Page42Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW II Power Control Configuration[HW II power control table] main parameters – 2[HW II power control table] main parameters – 2

Parameter name

Meaning Value range

Recommended value

PC interval Time between two power control command implementation 1~30

(SACCH period)

5

UL RX_LEV upper

threshold

This parameter specifies the uplink signal level upper threshold. When the signal level higher than this value, calculate a power

decrement [=receiving level - (upper threshold + lower threshold)/2]. This decrement value should consider together with

the maximum step size allowed for different quality zone which the receiving signal quality located.

0~63 (-110 dBm – -47 dBm)

35

UL RX_LEV lower

threshold

This parameter specifies the uplink signal level lower threshold. When the signal level lower than this value, calculate a power

increase [= (upper threshold + lower threshold)/2- receiving level]. This increase also consider together with the maximum step size

allowed for different quality zone which the receiving signal quality located.

0~63 (-110 dBm – -47 dBm)

25

UL Qual. upper

threshold This parameter specifies the uplink quality upper threshold.

Level 0~7

0

UL Qual. lower

threshold

This parameter specifies the uplink quality lower threshold for power control

Level 0~7

2

Page 43: OMF010003 Power Control ISSUE1.5

Page43Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW II Power Control Configuration[HW II power control table] main parameters [HW II power control table] main parameters –– 33

Parameter name

Meaning Value range

Recommended value

DL RX_LEV upper threshold

This parameter specifies the downlink signal level upper threshold. When the signal level higher than this value, calculate a power decrement [=receiving level – (upper threshold + lower threshold)/2]. This decrement should consider together with the maximum step size allowed for different quality zone which the receiving signal quality located.

0~63 (-110 dBm –

-47 dBm) 40

DL EX_LEV lower threshold

This parameter specifies the downlink signal level lower threshold. When the signal level lower than this value, calculate a power increase [= (upper threshold + lower threshold)/2- receiving level]. This increase also consider together with the maximum step size allowed for different quality zone which the receiving signal quality located.

0~63 (-110 dBm –

-47 dBm) 30

DL Qual. upper threshold

This parameter specifies the downlink quality upper threshold for power control

Level 0~7 0

DL Qual. lower threshold

This parameter specifies the downlink quality lower threshold for power control

Level 0~7 2

Page 44: OMF010003 Power Control ISSUE1.5

Page44Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

[HW II power control table] main parameters [HW II power control table] main parameters –– 44Parameter

name Meaning Value range

Recommended value

MAX Down Adj. value Qual.

zone 0

This parameter specifies the maximum downward power adjustment value when the Rx quality is 0.

0~30dB 16

MAX Down Adj. value Qual.

zone 1

This parameter specifies the maximum downward power adjustment value when the Rx quality is 1 or

2 0~30dB 8

MAX Down Adj. value Qual.

zone 2

This parameter specifies the maximum downward power adjustment value when the Rx quality is

equal to or more than 3. 0~30dB 4

MAX Down Adj. PC Value by

Qual.

The adjustment step allowed for the downward power control due to receiving signal quality.

0~4dB 4

HW II Power Control Configuration

Page 45: OMF010003 Power Control ISSUE1.5

Page45Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW II Power Control Configuration[HW II power control table] main parameters [HW II power control table] main parameters –– 55

Parameter name

Meaning Value range Recommended

value

MAX Up Adj. PC Value by

RX_LEV

It is used to set the maximum adjustment step for upward power control by receive level.

0~32dB 16

MAX Up Adj. PC Value by

Qual.

It is used to set the maximum adjustment step for upward power control by receive quality.

0~32dB 8

UL Qual. Bad TrigThrsh

In uplink power control, when the receiving quality of uplink is not less than this start threshold, the

actual "upper threshold of signal strength of uplink" will be added with "upper threshold offset of level when the receiving quality of uplink is poor" in the

data configuration. Thus, the expected level in uplink power control can be increased furthermore.

0~7 5

UL Qual. Bad UpLEVDiff

In uplink power control, when the receiving quality is not less than "start threshold when the receiving

quality of uplink is poor", the actual "upper threshold of signal strength of uplink" will be added with this

offset value.

0~63dB 0

Page 46: OMF010003 Power Control ISSUE1.5

Page46Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

HW II Power Control Configuration[HW II power control table] main parameters [HW II power control table] main parameters –– 66

Parameter name

Meaning Value range Recommended

value

DL Qual. Bad TrigThrsh

In downlink power control, when the receiving quality of downlink is not less than this start

threshold, the actual "upper threshold of signal strength of downlink" will be added with "upper

threshold offset of level when the receiving quality of downlink is poor" in the data configuration. Thus, the expected level in downlink power control can be

increased furthermore.

0~7 5

DL Qual. Bad UpLEVDiff

In downlink power control, when the receiving quality is not less than "start threshold when the receiving quality of downlink is poor", the actual

"upper threshold of signal strength of downlink" will be added with this offset value.

0~63dB 0

Page 47: OMF010003 Power Control ISSUE1.5

Page47Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Exercises for HW II power control

Given conditions: The uplink receiving level is -55dBm, the quality is level 0. Power

control algorithm is HW II.

Data configuration is as follows: Uplink signal level upper threshold: -60dBm, uplink signal level lower threshold: - 80dBm. Uplink signal upper quality threshold: level 1. Uplink signal lower quality threshold: level 2. The downward adjustable step size of quality band 0 is 16dB, of quality band 1 is 8dB, and of quality 2 is 4 dB. The upward adjustable step size of receiving level is 16dB. The upward or downward adjustable step size for power control by quality are both 4dB.

Question: What will be the uplink stable receiving level after power control?

ExerciseExercise

Page 48: OMF010003 Power Control ISSUE1.5

Page48Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Exercise Exercises for HW II power control

Answer. First, transmitting power to be reduced according to receiving level = a

ctual receiving level -(uplink signal level upper threshold + uplink signal level lower threshold)/2 = -55- (-60 + (-80))/2 = (-55)-(-70) = 15dB. As the receiving quality is level 0, downward adjustable step size of quality band 0 can be used -- decrease 16dB.

Second, the transmitting power to be decreased according to receiving quality = as “power control adjustment step size by quality” is 4dB, thus decrease 4dB.

Therefore, according to the general judgement on power control, 15dB should be decreased.

Page 49: OMF010003 Power Control ISSUE1.5

Page49Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.

Exercise

Exercises for HW II power control

Answer .

After the implementation of step 1 power control, the

receiving level becomes: -55dBm-15dB= -70dBm, Suppose

the quality reach already in level 1 here.

First: the receiving level value is between -80dBm~-60dBm,

needn’t adjust.

Second: the receiving quality value is between 0 and 2,

needn’t adjust.

Therefore, the uplink stable receiving level =-70dBm.

Page 50: OMF010003 Power Control ISSUE1.5

Thank youwww.huawei.com