6
Cooling 100÷465 kW Heating 100÷480 kW General High efficiency modular multifunctional units for 4-pipe systems. Scroll compressors, 2 refrigerant circuits. Plate heat exchangers for cooling- and heating water circu- its. Air source, axial fans. Configurations HE: high efficiency unit /LN: low noise unit SLN: super low noise unit Omicron Rev S4 Multi-functional units for 4-pipe systems Bullet points High efficiency in every condition Single equipment to satisfy the whole system’s load Minimized impact of defrost on heating mode Extended operation limits Bluethink advanced control with integrated web server Multilogic function for multiple units’ system (op- tion) Blueye supervision system (option) Flowzer: system with variable water flow (options). Flowzer VFPP implemented on each water circuit Integrated hydraulic modules (options): one or two pumps on each water loop, also inverter-driven

Upload: others

Post on 22-Jun-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Omicron Rev S4 · 2019-10-14 · OMICRON REV S4 can operate down to -15°C, granting heating output without interruptions. In fact, the defrost cycle can be a critical condition:

Blue Box Group S.r.l.Via Valletta, 5 - 30010 Cantarana di Cona, (VE) Italywww.bluebox.it - [email protected] +39 0426 921111 - Fax +39 0426 302222

Cool

ing 1

00÷

465

kWH

eatin

g 1

00÷

48

0 kW

General

High efficiency modular multifunctional units for 4-pipe systems. Scroll compressors, 2 refrigerant circuits. Plate heat exchangers for cooling- and heating water circu-its. Air source, axial fans.

Configurations

HE: high efficiency unit/LN: low noise unitSLN: super low noise unit

Omicron Rev S4Multi-functional units for 4-pipe systems

Bullet points

► High efficiency in every condition

► Single equipment to satisfy the whole system’s load

► Minimized impact of defrost on heating mode

► Extended operation limits

► Bluethink advanced control with integrated web server

► Multilogic function for multiple units’ system (op-tion)

► Blueye supervision system (option)

► Flowzer: system with variable water flow (options). Flowzer VFPP implemented on each water circuit

► Integrated hydraulic modules (options): one or two pumps on each water loop, also inverter-driven

Page 2: Omicron Rev S4 · 2019-10-14 · OMICRON REV S4 can operate down to -15°C, granting heating output without interruptions. In fact, the defrost cycle can be a critical condition:

Year

Load

MAX

S AV I N G€

MAX

S AV I N G€

Mode: heating(full load)

-15°CT air

Mode: cooling(full load)

up to

45°CT air

Heating(for T air down to -1°C)

or Combined mode

up to

55°CT water

THE SOLUTION FOR

4-PIPE SYSTEMS

PERFORMANCE EXTENDED THROUGHOUT THE YEAR

With nowadays construction techniques and increased ther-mal insulation, depending on solar exposure more and more commercial buildings require simultaneous cooling and heat-ing during mid season and winter.

Moreover, latest European regulations are incentivizing the use of electrical heat pumps for heating, even in Northern European countries.

OMICROV REV S4 range has been designed to fulfill this mar-ket demand about providing cooling and heating simultane-ously for warm and cold climates as well.

Operational limits favourable also for the heating mode: up to 55°C leav-ing water temperature.This is ideal for modern, energy-effi-cient buildings.

OMICRON REV S4 can operate down to -15°C, granting heating output without interruptions.In fact, the defrost cycle can be a critical condition: OMICRON REV S4 features totally independent coils’ sections for each refrigerant circuit, thanks to its modular layout.By this way, the unit can still operate in heating mode while one circuit is defrosting, with limited disruption on delivered water temperatures.

Page 3: Omicron Rev S4 · 2019-10-14 · OMICRON REV S4 can operate down to -15°C, granting heating output without interruptions. In fact, the defrost cycle can be a critical condition:

HE: Highefficiency

SLN: Super low noise

100

above

3.16above

3.30

EER COP

kW

coming soon (additional sizes with 8 compressors, 4 circuits)

450 900

WIDE CAPACITY RANGE

COMPACT& EASY

HighEfficiencyExcellent efficiency at full load, especially for cooling mode.

Moreover, outstanding part-load performances can be achieved thanks to the partialization steps and the smart logic developed for OMICRON REV S4, also in the case of multiple units integrated into a single large system.

Efficient multifunctional units such as OMICRON REV S4 allow to obtain better ratings, compared to alternative tradi-tional systems, in programmes or incentives based on energy efficiency and sustainability.Qualifying the system in such a way provides also an intrinsically higher value for the building.

Capacity exceeding 200 kW in just 2,3 m length.

This means an easy design that mini-mizes the footprint occupied by the unit and the auxiliary equipment as well.

A peculiar advantage for refurbish-ment projects, involving the replace-ment of two different generators and their pipings for heating and cooling.

Also for new buildings, a simplified and smart layout of the whole system provides a remarkable benefit.

Super low noise version (SLN) has the same dimensions as the HE version.

Net cooling capacity according to EN14511Conditions: EER=A35 W12-7; COP=A7(6) W40-45All data are PRELIMINARY

Page 4: Omicron Rev S4 · 2019-10-14 · OMICRON REV S4 can operate down to -15°C, granting heating output without interruptions. In fact, the defrost cycle can be a critical condition:

c o n t r o l p l a t f o r m

Set pointoperating unit set

point

Servicethermoregulation and

dynamic setpoint

Alarmalarm history

In/Outdigital and

analogic output and input signal

Synopticgraphic or chart unit

diagram

Graphsin-out temparature,

pressure, superheat in real time

Integrated web server

main features

USB, RS485 and Ethernet ports as standard Recording of unit parameters one month long

MULTILOGIC FUNCTION Multiple units can be managed with different function logics according to different installa-

tion requirements The system is fully embedded in the control and factory-preset

BLUEYE Supervision system by Blue Box that allows several function and advantages as monitoring

one or more units, pumps, energy meters, valves, record parameters and graphs in the cloud

FLOWZERThe new family of hydraulic management scalable options. Associated to the wide range of built-in pump modules (offered as options), FLOWZER provides the best-fitting solution for the water distribution to the system, at minimized operational cost: Flowzer VP: Inverter pump for fixed speed, with double setting Flowzer VD: Constant delta P regulation with inverter pump Flowzer VFPP: Variable flow on primary circuit

ECAXIAL FANSEC axial fans with electronically commu-tated brushless motor as option.

15% energy saving per fan

2.000* €/y saving

(*unit with 8 fans; operating 8700 hours/year; 0,10€/kW)

NIGHT SHIFT SYSTEMThe unit can operate in high efficiency mode or super low noise mode accor-ding to daytime setting.

Omicron Rev S4 HE* Omicron Rev S4 SLN

up to 3 dB(A) of sound power reduction

*Omicron Rev S4 HE must be appropriately configured

24

12

618

123 222321

420519

717

816915

10141113

Page 5: Omicron Rev S4 · 2019-10-14 · OMICRON REV S4 can operate down to -15°C, granting heating output without interruptions. In fact, the defrost cycle can be a critical condition:

MONTE DEI PASCHI DI SIENASiena - Italy

4x multifunctional unitsSupply -> 2,16 MW

Page 6: Omicron Rev S4 · 2019-10-14 · OMICRON REV S4 can operate down to -15°C, granting heating output without interruptions. In fact, the defrost cycle can be a critical condition:

Blue Box applied product rangefind out the complete product range on our web site and catalogues

Blue Box Group S.r.l.Via Valletta, 5 - 30010 Cantarana di Cona, (VE) Italywww.bluebox.it - [email protected] +39 0426 921111 - Fax +39 0426 302222

Epsilon Echos series > 6÷44 kW High efficiency air cooled chillers and heat pumps.

EC

Zeta Rev > 40÷240 kW Beta Rev > 40÷240 kW High efficiency air cooled chillers and heat pumps.

EC & AC

Kappa Rev series > 296÷1983 kW High efficiency air cooled modular chillers and heat pumps.

Omega Rev series > 143÷1569 kW Water-cooled chillers and heat pumps.

Omicron V Evo > 335÷773 kW Air cooled multifunctional units for 4-pipe systems or independent production of domestic hot water, heating and cooling.

Tetris 2 series > 84÷913 kW High efficiency air cooled modular chillers and heat pumps.

Kappa V Evo series > 637÷1750 kW Air cooled water chiller.

Tetris W Rev series > 32÷615 kW High efficiency water cooled chillers and heat pumps.