omnipcx office

31
Arquitectura Arquitectura

Upload: 82068740

Post on 21-Oct-2015

77 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: OmniPCX Office

ArquitecturaArquitectura

Page 2: OmniPCX Office

2

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Las PYMEs necesitan una arquitectura ampliable

Vida de la compañía

Usuarios y/o servicios

Capacidad necesaria

Page 3: OmniPCX Office

3

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Arquitectura modular y ampliable: índice

Solución Alcatel: Arquitectura

Arquitectura modular y escalable Producto modular: rack 1/2/3 Arquitectura general Placas de Aplicaciones y de Procesamiento Placas de líneas Placas de enlaces Llaves software: modularidad mejorada Capacidades Conclusiones

Page 4: OmniPCX Office

4

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Es posible cualquier

combinación de rack: hasta 3

racks

Rack 1Rack 1

Rack 2Rack 2

Rack 3Rack 3

Arquitectura ampliable : Plataforma única

+

Una plataforma única:Hardware comúnSoftware único : misma CPU

Capacidades máximas de usuarios :

84 puertos de datos 10/1006 Go para datos (Proxy, Caching, e-mail…)6 Go para voz (Mensajería Vocal, música, directorio…)236 abonados telefónicos

Page 5: OmniPCX Office

5

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Producto Modular: rack S/M/L

Diseño apilable y en rack: Apilable: se pueden apilar hasta 3 racks

Montaje en rack: con un kit de montaje (“anclajes”) el producto se puede colocar en un rack Nota : 1U = 1,75 pulgadas = 44,45 mm so Rack S= 1.5 U, Rack M= 2.5U, Rack L 3.5U

Anchura=442mm

Fondo=

400mmAltura=66mmRack 1

Altura=110mm

Rack 2

Altura=154mm

Rack 3

Page 6: OmniPCX Office

6

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

CPUCPU

Para todos los racks el slot de CPU es dedicado.

BRA-4BRA-4

UA-16UA-16

CPUCPU

CPUCPU

Producto Modular: placas

Rack 12 slots universales: cualquier placa en

cualquier slot (excepto SLI 16).

Fuente de alimentación con batería.Rack 2

5 slots universales: cualquier placa en

cualquier slot

Fuente de alimentación con batería.Rack 3

4 slots universales

4 slots específicos = cualquier

placa excepto placas Mixtas y UAI

16

Fuente de alimentación con

batería.

ARA-4ARA-4

1 2 3 4

ARA-16ARA-16

9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8

BRA-4BRA-4

1 2 3 4

PRAPRA

|| XBUSY RAI AIS NOS CRC LOS

ZLA-8ZLA-8

1 2 3 4 5 6 7 8

ZLA-8ZLA-8

ZLA-16ZLA-16

ARA-8ARA-8

ZLA-16ZLA-16

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

CoCPUCoCPU LS5 LS6 LAN WAN

LS1 LS2 LS3 LS4

CoCPUCoCPU LS5 LS6 LAN WAN

LS1 LS2 LS3 LS4

PRAPRA

|| X

ZLA-4ZLA-4

1 2 3 4

Page 7: OmniPCX Office

7

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Slot 1 Slot 2

Slot 3 Slot 4 Slot 5

Slot 6 Slot 7 Slot 8

CPUCPU

Rack 3: placas

4 slots universales : slot 1, 2, 3,

4.

4 slots específicos : slot 5, 6, 7, 8.

Cualquier placa excepto UAI 16 y

Placas Mixtas Board Slot1-2-3-4

Slot5-6-7-8

CPU,CPUe ,MEXCoCPU,CoCPU@ OOKK OOKKBRA-2,4,8 OOKK OOKKPRA-T2/E1 OOKK OOKKATA-4 OOKK OOKKUAI16 OOKKUAI-4,8 OOKK OOKKSLI-4,8,16 OOKK OOKKMIXx/y/z OOKKLanX8 LanX16 OOKK OOKK

Page 8: OmniPCX Office

8

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Ampliable : ampliación de armarios

Se pueden conectar hasta 2 armarios adicionales al armario principal. Es posible cualquier

combinación. Rack 1+ Rack 2 o Rack 2+Rack 1 o…

La CPU del armario principal

gestiona el resto de los

armarios. Hay una única CPU

por sistema.

El sistema se puede ampliar gracias a la unión HSL y a la placa MEX.

CoCPUCoCPU

PRAPRA

|| X

SLI-8SLI-8

CPUCPU

BRA-4BRA-4

UAI-16UAI-16

SLI-8SLI-8

UAI-16UAI-16

UAI-16UAI-16

[Armario Principal]

MEXMEX

CoCPUCoCPU UAI-8UAI-8

[Armario Satélite 2]

FANPOWER

UAI-16UAI-16 SLI-8SLI-8

MEXMEX CoCPU@CoCPU@ SLI-8SLI-8

BRA-4BRA-4

[Armario Satélite 1]

FANPOWER

Unión HSL

(En Entrada Master de

MEX) Unión HSL

(En Entrada Master de MEX)

Page 9: OmniPCX Office

10

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Modular y fácilmente ampliable

Parte Frontal

Arquitectura General

Baterías

Fuente de Alimentación

Toma Principal

Backpanel

Area técnica de refrigeración

Area de Placas

No hay cableado interno dentro del rack

La extracción y fijación de las placas de Aplicaciones y de CPU se realizan únicamente con un tornillo...

Page 10: OmniPCX Office

11

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Placas de Procesamiento y Aplicaciones

(1) se necesita CPUe para mensajería vocal de 6 o más puertos

SoloSolo

VOZ (1)VOZ (1) + VPN+ VPN+ Proxy, + Proxy,

caché,caché,

servidor e-servidor e-mail mail

SS

MM

L, L, XLXL

CPU CPUe

+CoCPU@

+ Disco duro de Datos

VOZ +VOZ +

ACCESOACCESO

INTERNEINTERNETT

+ Disco duro de Datos

VoIP,VoIP,

Telfonía IPTelfonía IP

+ Disco duro de Datos

CPUe (con SDRAM 128)

+

CoCPUy

placa hija VoIP

Page 11: OmniPCX Office

12

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Placas de Procesamiento:CPU/CPUe

Interface V24 para conexión a PC (PM5)

Unión Ethernet 10/100BaseT: conexión a LAN del cliente

Conexión de armarios de expansión a través de la unión HSL ( Se necesita placa hija HSL )

Megafonía y alarma( Se necesita placa hija AFU )

Portero A y B ( Se necesita la placa hija AFU )

Equipo de audio o música exetrna + 12V para control y usuario( Se necesita placa hija AFU)

Interruptor de Shutdown

Timbre General Equipado de base

Led bicolor de fallo de ventilador

CPU para Voz

CPUe para Voz y Acceso InternetLed de

alimentación

No usado

Page 12: OmniPCX Office

13

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Placas hijas en Unidad de Procesamiento (CPU)

XMEM 64 : expansión de memoria tanto para servicios de voz como aplicaciones internet

HSL1 or 2 : Inter-conexión entre armarios.

. HSL1: placa hija para la conexión de un primer módulo adicional

. HSL2: placa hija para la conexión de dos módulos adicionales

AFU : conexión de funciones auxiliares, Música en espera (entrada/salida audio, bucle, silencio), portero, alarma

Disco duro de Voz: expansión de memoria para servicos de voz mejorados (almacenamiento de mensajería vocal desde 80mn a 200 horas, operadora automática con todas las facilidades, audiotext, grabación en línea,…)

Placas hijas en Unidad de Procesamiento (CPU)

Page 13: OmniPCX Office

14

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Estructura de placas CPU/CPUe

Estructura de CPU ,CPUe CPU

Hard Disk

XMEM or VoIP

SDRAM

AFU

HSL

Con

ecto

r M

ETR

IC a

backp

an

el

Fro

nta

l R

J-4

5

Con

ecto

res C

at.

5

System signals

Sh

utd

ow

n S

wit

ch

Xmem or VoIP &

2.5” HD

AFU Aux function Module

SDRAM Module

ASPEN

HSL Led

272 mm

134mm

Page 14: OmniPCX Office

15

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Placas de Procesamiento para Aplicaciones :

CoCPU/CoCPU@

Placa de Co-procesamiento VoIP: CoCPU

16 Canales VoIP

Placa de Co-procesamiento : CoCPU@

3 x 10/100 Base T Puertos Ethernet de la placa hija SLANX4 10/100 Base T Ethernet Up-Link de

placa hija SLANX4

Leds de Estado de Línea y Actividad de puertos de SLANX4

Page 15: OmniPCX Office

16

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Placas hijas en unidad de Coprocesamiento (CoCPU)

SlanX4 : LANswitch para interconectar una CPU con hasta 2 CPU

Disco duro de datos: Expansión de memoria para servicios Internet (servidor Proxy/Cache, servidor e-mai)- conectable solo en CoCPU@.

Conectividad Ethernet (WAN): Conexión para módem ADSL o router externo conectable en CoCPU@

VoIP: Recursos de Voz sobre IP (canales IP) - Modularidad: 4, 8, 16 canales IP conectables en CoCPU.

Descripción del hardware

Page 16: OmniPCX Office

17

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

CoCPU,CoCPU@ Descripción del hardware

Hardware CoCPU ,CoCPU@ .C

on

ecto

r M

ETR

IC a

backp

an

el

Fro

nta

l R

J-4

5

Con

ecto

r C

at.

5

System signals

Sh

utd

ow

n S

wit

ch

Xmem or VoIP &

2.5” HD

only on CoCPU

WAN

only on CoCPU@ SDRAM Module

ASPEN

CPU

Disco duro

XMEM o VoIP

SDRAM

SlanX

SlanX

Led

Módulo 32MBytes SDRAM para CoCPU

Módulo 128MBytes SDRAM para CoCPU@

Page 17: OmniPCX Office

18

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Conexión entre Placas de Procesamiento y Co-Procesamiento

Una única conexión a la LAN del cliente

CoCPU@ con placa hija SLANX

Estas placas no están necesariamente en el mismo armario

Page 18: OmniPCX Office

19

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Placas de Líneas Placa interfaz Reflexes : UAI

modularidad: 4, 8, 16

Placa interface Analógico : SLI modularidad:

4, 8, 16

Placas de Líneas

Page 19: OmniPCX Office

20

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Placas de enlaces Acceso RDSI T0 : BRA

modularidad 2, 4, 8

Acceso RDSI T2: placa PARA-T2

Placas de enlaces

Conector de categoría 3

apantallada RJ45

Leds de Alarmas de

Red

Conexión al Punto de Terminación de Red ( NT1) Red de PABXs ( QSIG)

ISDN ACCESS -E1

BUSY

AISRAI

NOS CRC LOS PBX X

NETW ||

PRA-T2

Page 20: OmniPCX Office

21

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

6 Placas Mixtas:

2T0/4UA/4Z, 4T0/4UA/8Z,4T0/8UA/4Z,

4UA/4Z, 4UA/8Z, 8UA/4Z

Placas Mixtas

Mixed Lines

1 2 3 4 5 6 7 8

1 2 3 4 1 2 3 4

Digital Interface

Analog Interface MIX4/8/4 ISDN T0

P.e. : placa de 4T0-8UA-4Z

Conector RJ45 apantallado de Categoría 3

Page 21: OmniPCX Office

22

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Placas Mixtas

Placa 4T0-4UA-8Z

Placa 2T0-4UA-4Z

Placa 4T0-8UA-4Z

Mixed Lines

1 2 3 4 5 6 7 8

1 2 3 4 1 2 3 4

Digital Interface

Analog Interface MIX4/8/4 ISDN T0

Mixed Lines

1 2 3 4 1 2 3 4

1 2 3 4 5 6 7 8

Digital Interface

Analog Interface MIX4/4/8 ISDN T0

Analog Interface

Mixed Lines

1 2 3 4 1 2 3 4

1 2 Not Used Not Used Not Used Not Used Not Used Not Used

Digital Interface

MIX2/4/8 ISDN T0

Analog Interface

Conector RJ45 apantallado de Categoría 3

Page 22: OmniPCX Office

23

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Placas Mixtas

Placa 0T0-8UA-4Z

Placa 0T0-4UA-8Z

Mixed Lines

1 2 3 4

1 2 3 4

5 6 7 8

Digital Interface

Analog Interface

MIX0/4/8

Analog Interface

Mixed Lines

1 2 3 4

5 6 7 8

1 2 3 4

Digital Interface

Analog Interface

MIX0/8/4 Not Used Not Used Not Used Not

Used

Not Used Not Used Not Used Not Used

Conector RJ45 apantallado de Categoría 3

Placa 0T0-4UA-4Z

Mixed Lines MIX0/4/8

1 2 3 4

1 2 3 4

Digital Interface

Analog Interface

Page 23: OmniPCX Office

24

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Lanswitch Ethernet 10/100 BaseT : LANX

LANX16 Ethernet LanSwitch

9 10 11 12 13 14 15 Up-Link

1 2 3 4 5 6 7 8

LanX16

LanX

LANX8

Puerto Ethernet 10/100 Base TTipo de conexión MDI-X

Led de estado de la línea y Actividad

Led Indicador de Velocidad

Puerto Up - Link Ethernet 10/100 Base TTipo de Conexión MDI-II

Conector RJ45 apantallado de Categoría 3

ON : Full Duplex

Off: Half Duplex

Parpadeando: Colisión

ON: Conectado

Off: no conectado

Parpadeando:Actividad

Page 24: OmniPCX Office

25

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Fuente de Alimentación

Fuente de Alimentación PS1--> Rack 1 PS2--> Rack 2 PS3--> Rack 3

Baterías Rack 1 : 1 batería, autonomía de 10-20 mn. Rack 2 : 2 baterías en paralelo, autonomía de 10-20 mn. Rack 3 : 3 baterías montadas en serie, autonomía de 10-20 mn. Capacidad de la batería: 12V/1,2 Ah

UPS Modelo S : 300 VA / Autonomía 1 h. Modelo M: 650 VA / Autonomía 1 h. Modelo L : 1200 VA / Autonomía 1h. Modelo XL: 1200 VA/ Autonomía 40 mn. Se colocará una UPS por cada 2 módulos de OmniPCX Office

Page 25: OmniPCX Office

26

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Todo el software está cargado en la CPU para Datos Internet Voz

Para implementar nuevos servicios o aumentar el número de usuarios

Cambiar llave software Fácil de hacer remotamente

Fundamento de las Llaves Software

Llaves Software : mejorando la modularidad

Page 26: OmniPCX Office

27

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Capacidades del Sistema

Límites Máximos

SistemaAsociación de armarios hasta 3 armariosNº total de slots incluyendo CPU y placas MEX

27

Slots libres 24Co-processing CPU (CoCPU) de las cuales hay 1 CoCPU@ max. por sistema

6

Canales DSP en CoCPU 96Disco Duro 2Capacidad de Disco Duro 6 GbytesPuertos de ComunicacionesPuertos de Usuario (Reflexes + Analógico)

200

Multi-Reflexes Hubs 18

Placas LANswitch 6 x LanX16

Puertos LANswitch libres (1) 84Enlaces Analógicos(2) (NDDI - DDI - TieLine)

72

Accesos Primarios 9Accesos Básicos 12Enlaces IP 120

Total Enlaces 120

Puertos para conmutación de

Paquetes (LAN): 84

Puertos para conmutación de

Circuitos

200

(1) Se utilizan 2 puertos LAN:

1 para interconectar LAN a CPU 1 uplink reservado para conectar un LANswitch externo

(2) Disponible en Release 1.1

Page 27: OmniPCX Office

28

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Capacidades:Servidor de Voz, e-server

2 Discos duros :

6 Go para datos

Proxy, Caching, e-mail

6 Go para voz

Mensajería Vocal, música, directorio...

Capacidades Máximase-serverAcceso Internet Compartido* RDSI hasta 128 Kbps (2 canales B)* Módem o router ADSL externo hasta 2 MbpsAutenticación PAP/CHAPUsuarios Internet 200Firewall Filtrado IP / NATProxy/caché 1,5 Gb para caché web

servidor e-mail POP3/SMTP/MIME/ETRN

E-mail boxes 200

Capacidad de almacenamiento e-mail 3,7 Gb.VPN PPTP/IPSecServidor de VozPuertos de Mensajería Vocal de 2 a 8 Almacenamiento en MV hasta 200 horas

Operadora Automática2 niveles / 10 opciones por

nivel/subnivelGrupos Cíclico/paralelo/secuencialBienvenida hasta 8Música en espera hasta 10 mn.Idiomas hasta 4Entradas de directorio 3000Relección Automática de Ruta (SAR) 500 entradas

Page 28: OmniPCX Office

29

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Capacidades:Terminales, Lugar de trabajo &

Movilidad

Terminales y Lugar de Trabajo

Número de Abonabos en Directorio 250

Terminales Reflexes+analógicos 236

Terminales Reflexes 236Terminales Analógicos 196Abonados IP (IP Reflexes + PIMPhony IP Media)

200

Clientes H323 PC 150Clientes PIMphony con servidor CTI integrado (incluyendo IP PIMphony Media) 25Sesiones CSTA 28Monitorizaciones CSTA 208Opciones de Reflexes Módulos add-on (max 2 por puerto) 136Adaptador S0, V24, Z 48

Adaptador V24 tarificación 1

EDN múltiple por S0 98MovilidadIBS (alimentación remota) 60IBS (alimentación local) 199

Mobile Reflexes 235

Page 29: OmniPCX Office

30

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Una única arquitectura para una amplia gama de mercado: Voz, datos e internet 236 usuarios (IP, analógico, DECT,softphone) Fácil gestión de stock para distribuidores

Modular & Ampliable : Gama de placas (las placas mixtas permiten

una configuración precisa) Gama de racks (3) con slots universales Ampliación a través de racks adicionales Llaves software

Beneficios de la arquitectura OmniPCX Office

ArquitecturaConclusión

Page 30: OmniPCX Office

31

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

Page 31: OmniPCX Office

37

All

rig

hts

rese

rved

-Pass

ing

on a

nd

cop

yin

g o

f th

is d

ocu

ment,

use

and

com

munic

ati

on

of

its

conte

nts

not

perm

itte

d w

ithout

wri

tten a

uth

ori

zati

on f

rom

Alc

ate

l

Alcatel OmniPCX Office / Arquitectura / Marketing

RESPUESTAS

1.- b- Comunicaciones de voz y datos en infraestructura de circuitos y de paquetes

2.- a- & b- Es fiable e integra los principales protocolos Internet

3.- a- 1 : una única CPU por sistema. Tenemos 2 tipos de CPU: CPU y CPUe pero hay una única CPU por sistema. Es posible tener hasta 6 CoCPU en un sistema, de las cuales hay una única CoCPU@

4.- a- & c- servidor e-mail y servidor CTI 5.- c- e-communication appliance 6.- c- numerosos 7.- c- 3 racks y 1 software 8.- b- El slot de la placa MEX y el de la CPU

9.- a- CPUe 10.- b- CoCPU 11.- a- CoCPU@ 12.- b- SLI 4 13.- a- 4, 8,16 14.- c- un switch Ethernet10/100BT 15.- c- hasta 235 16.- b- 6