Standard Use Guidelines: For life threatening hemorrhage situa- tions. For the military in the Care Under Fire situation, treatment normally consists of using a tourniquet immediately to stop ma- and authorized rescuer will perform all treatment necessary us- ing the TMT as a last resort and should only be applied when bleeding cannot be stopped and the situation is life threatening. FDA Registered This is a SINGLE USE device. Always store in one-handed configuration. ONE-HANDED OPERATION INSTRUCTIONS Hold the end of the strap by the white time label tab, allow the TMT to fall open with the word “PULL” facing away from you. Place around the injured extremity high and tight above the wound. Pull time tab until Velcro ® Brand material tail is separated from the TMT. and away from the body and then downward in a quick ratcheting motion. Repeat step until snug around extremity. Adjust/rotate the TMT on extremity for ease of access to the torsion bar. Twist torsion bar until bleeding stops and the pulse is not present. Lock the torsion bar into the retainer. Secure excess strap with Velcro ® Brand material. TO RELEASE/REMOVE THE TMT: Unwrap excess tail from the Velcro ® Brand material, put positive pressure on torsion bar, apply upward pressure on the retaining clip and push torsion bar out, then unhook buckle. store in one-handed Savior Global 8 Ash Gardens Hamworthy, Poole, Dorset BH15 4DE United Kingdom EC REP 1 2 3 4 5 REMOVAL GRIP PULL UP PULL DOWN ADJUST TWIST Grip tail close to the buckle, firmly pull up, out Patent Pending jor bleeding of the extremities. In field care situation, the trained TACTICAL MECHANICAL TOURNIQUET Distrbuted by: Combat Medical 5555 Harrisburg Industrial Park Drive Harrisburg, NC 28075 USA 1-855-428-6074 www.combatmedicalsystems.com 31-115 | CMS-PUB-TMT-04-003 TM Alphapointe 3611 14th Avenue Brooklyn, NY 11218 USA CAGE Code: 056F9 Made in USA Pat. Info: combatmedicalsystems.com/ip NSN: 6515-01-656-6191 V3 Limitation of liability: Alphapointe, its employees, agents, con- tractors, suppliers, and distributors shall assume no liability for injury or damages arising from the application and use of the TMT. ONLY use the TMT as directed in the instructions for use. Do not remove the slider from the strap. The user assumes all risk liability. It is recommended to receive appropriate first aid training. ISO 9001:2015 Certified

Upload: others

Post on 02-Aug-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ONE-HANDED OPERATION INSTRUCTIONS 1 2 TWIST LOCK 3 4 1 ... · 3 4 1 TACTICAL MECHANICAL TOURNIQUET Cage: 056F9PN# 60064 Cage: 056F9PN# 60064 ONE-HANDED OPERATION INSTRUCTIONS 2 Limitation

3 4

1

TACTICAL MECHANICAL TOURNIQUET

Cage: 056F9 PN# 60064

ONE-HANDED OPERATION INSTRUCTIONS

2

Limitation of liability: Alphapointe, its employees, agents, con-tractors, suppliers, and distributors shall assume no liability for in-jury or damages arising from the application and use of the TMT. The user assumes all risk liability. The TMT should only be used as directed in the military service component guidelines, EMS authority, or under direct supervision of a physician. Standard Use Guidelines: For life threatening hemorrhage situa-tions. For the military in the Care Under Fire situation, treatment normally consists of using a tourniquet immediately to stop ma-

and authorized rescuer will perform all treatment necessary us-ing the TMT as a last resort and should only be applied when bleeding cannot be stopped and the situation is life threatening.

Alphapointe3611 14th AvenueBrooklyn, NY 11218

FDA Registered This is a SINGLE USE device. ISO 9001: 2008 Certified

Always store in one-handed configuration.

Made in U.S.A.

3 4

1

TACTICAL MECHANICAL TOURNIQUET

Cage: 056F9 PN# 60064

ONE-HANDED OPERATION INSTRUCTIONS

2

Limitation of liability: Alphapointe, its employees, agents, con-tractors, suppliers, and distributors shall assume no liability for in-jury or damages arising from the application and use of the TMT. The user assumes all risk liability. The TMT should only be used as directed in the military service component guidelines, EMS authority, or under direct supervision of a physician. Standard Use Guidelines: For life threatening hemorrhage situa-tions. For the military in the Care Under Fire situation, treatment normally consists of using a tourniquet immediately to stop ma-

and authorized rescuer will perform all treatment necessary us-ing the TMT as a last resort and should only be applied when bleeding cannot be stopped and the situation is life threatening.

Alphapointe3611 14th AvenueBrooklyn, NY 11218

FDA Registered This is a SINGLE USE device. ISO 9001: 2008 Certified

TMTAlways store in one-handed con�guration.

Made in U.S.A.

Hold the end of the strap by the white time label tab, allow the TMT to fall open with the word “PULL” facing away from you. Place around the injured extremity high and tight above the wound.

Pull time tab until Velcro® Brand material tail is separated from the TMT. and away from the body and then downward

in a quick ratcheting motion. Repeat step until snug around extremity.

Adjust/rotate the TMT on extremity for ease of access to the torsion bar. Twist torsion bar until bleeding stops and the pulse is not present.

Lock the torsion bar into the retainer. Secure excess strap with Velcro® Brand material.

TO RELEASE/REMOVE THE TMT: Unwrap excess tail from the Velcro® Brand material, put positive pressure on torsion bar, apply upward pressure on the retaining clip and push torsion bar out, then unhook buckle.

NSN: 6515-01-656-6191

TACTICAL MECHANICAL TOURNIQUET

3 4TWIST LOCK

PN# 60064 Cage: 056F9

up, allow tourniquet to fall open. Place around injured extremity HIGH AND TIGHT above wound.

Dual Locking Mechanism will maintain pressure when tourniquet is applied, evenif hook and loop is not completely secure.

Twist the torsion bar (tightening the band) until bright red bleeding stops and the distal pulse is non-palpable.

Lock the torsion bar into retainer. Ensure the torsion bar is secure before release of positive control. Secure excess strap length by wrapping over torsion bar providing additional security.

TO RELEASE: Maintain positive control. Lift retainer clip up and push torsion bar out, then unhook strap.

Limitation of liability: Alphapointe, its employees, agents, con-tractors, suppliers, and distributors shall assume no liability for in-jury or damages arising from the application and use of the TMT. The user assumes all risk liability. The TMT should only be used as directed in the military service component guidelines, EMS authority, or under direct supervision of a physician. Standard Use Guidelines: For life threatening hemorrhage situa-tions. For the military in the Care Under Fire situation, treatment normally consists of using a tourniquet immediately to stop ma-

and authorized rescuer will perform all treatment necessary us-ing the TMT as a last resort and should only be applied when bleeding cannot be stopped and the situation is life threatening.

Alphapointe3611 14th AvenueBrooklyn, NY 11218

FDA Registered This is a SINGLE USE device.

Always store in one-handed

“CLICK”

Made in U.S.A.

MECHANICAL TOURNIQUET

TACTICAL MECHANICAL TOURNIQUET

NSN: 6515-01-656-6191 Cage: 056F9 PN# 60064

FDA Registered Patent Pending

This is a SINGLE USE device ISO 9001:20008 Certi�ed

Alphapointe3611 14th AvenueBrooklyn, NY 11218 Made in U.S.A.

Always storein one-handed

Savior Global8 Ash GardensHamworthy, Poole, DorsetBH15 4DE United Kingdom

EC REP

TOURNIQUET

To Release/Remove the TMT: Unwrap excess tail from the VELCRO® Brand material, put positive pressure on torsion bar, apply upward pressure on the retaining clip and push torsion bar out. Loosen at buckle and then unhook buckle.

Adjust/rotate the TMT on extremity for ease of access to the torsion bar. Twist torsion bar until bleeding stops and the pulse is not present.

Lock the torsion bar into the retainer. Secure excess strap with VELCRO® Brand material.

Grip tail close to the buckle, firmly pull up, out, and away from the body and then downward in a quick ratcheting motion. Repeat step until snug around extremity.

Hold the end of the strap by the white Time label tab, allow the TMT to fall open with the word “PULL” facing away from you. Place around the injured extremity high and tight above the wound.

Pull ,me tab un,l VELCRO® Brand material is separated.

TACTICAL MECHANICAL TOURNIQUET

3 4TWIST LOCK

1

PN# 60064 Cage: 056F9

ONE-HANDED OPERATION INSTRUCTIONS

2WRAP PULL

While holding end of strap with white Time Label up, allow tourniquet to fall open. Place around injured extremity HIGH AND TIGHT above wound.

Pull strap until tight around limb and secure remaining strap length down on itself. Dual Locking Mechanism will maintain pressure when tourniquet is applied, evenif hook and loop is not completely secure.

Twist the torsion bar (tightening the band) until bright red bleeding stops and the distal pulse is non-palpable.

Lock the torsion bar into retainer. Ensure the torsion bar is secure before release of positive control. Secure excess strap length by wrapping over torsion bar providing additional security.

TO RELEASE: Maintain positive control. Lift retainer clip up and push torsion bar out, then unhook strap.

Limitation of liability: Alphapointe, its employees, agents, con-tractors, suppliers, and distributors shall assume no liability for in-jury or damages arising from the application and use of the TMT. The user assumes all risk liability. The TMT should only be used as directed in the military service component guidelines, EMS authority, or under direct supervision of a physician. Standard Use Guidelines: For life threatening hemorrhage situa-tions. For the military in the Care Under Fire situation, treatment normally consists of using a tourniquet immediately to stop ma-

and authorized rescuer will perform all treatment necessary us-ing the TMT as a last resort and should only be applied when bleeding cannot be stopped and the situation is life threatening.

Alphapointe3611 14th AvenueBrooklyn, NY 11218

FDA Registered This is a SINGLE USE device.

Always store in one-handed

“CLICK”

Made in U.S.A.

MECHANICAL TOURNIQUET

TACTICAL MECHANICAL TOURNIQUET

NSN: 6515-01-656-6191 Cage: 056F9 PN# 60064

FDA Registered Patent Pending

This is a SINGLE USE device ISO 9001:20008 Certi�ed

Alphapointe3611 14th AvenueBrooklyn, NY 11218 Made in U.S.A.

Always storein one-handed

Savior Global8 Ash GardensHamworthy, Poole, DorsetBH15 4DE United Kingdom

EC REP

TOURNIQUET

1 2

3 4

1

5

TACTICAL MECHANICAL TOURNIQUET

3 4TWIST LOCK

PN# 60064 Cage: 056F9

up, allow tourniquet to fall open. Place around injured extremity HIGH AND TIGHT above wound.

Dual Locking Mechanism will maintain pressure when tourniquet is applied, evenif hook and loop is not completely secure.

Twist the torsion bar (tightening the band) until bright red bleeding stops and the distal pulse is non-palpable.

Lock the torsion bar into retainer. Ensure the torsion bar is secure before release of positive control. Secure excess strap length by wrapping over torsion bar providing additional security.

TO RELEASE: Maintain positive control. Lift retainer clip up and push torsion bar out, then unhook strap.

Limitation of liability: Alphapointe, its employees, agents, con-tractors, suppliers, and distributors shall assume no liability for in-jury or damages arising from the application and use of the TMT. The user assumes all risk liability. The TMT should only be used as directed in the military service component guidelines, EMS authority, or under direct supervision of a physician. Standard Use Guidelines: For life threatening hemorrhage situa-tions. For the military in the Care Under Fire situation, treatment normally consists of using a tourniquet immediately to stop ma-

and authorized rescuer will perform all treatment necessary us-ing the TMT as a last resort and should only be applied when bleeding cannot be stopped and the situation is life threatening.

Alphapointe3611 14th AvenueBrooklyn, NY 11218

FDA Registered This is a SINGLE USE device.

Always store in one-handed

“CLICK”

Made in U.S.A.

MECHANICAL TOURNIQUET

TACTICAL MECHANICAL TOURNIQUET

NSN: 6515-01-656-6191 Cage: 056F9 PN# 60064

FDA Registered Patent Pending

This is a SINGLE USE device ISO 9001:20008 Certi�ed

Alphapointe3611 14th AvenueBrooklyn, NY 11218 Made in U.S.A.

Always storein one-handed

Savior Global8 Ash GardensHamworthy, Poole, DorsetBH15 4DE United Kingdom

EC REP

TOURNIQUET

To Release/Remove the TMT: Unwrap excess tail from the VELCRO® Brand material, put positive pressure on torsion bar, apply upward pressure on the retaining clip and push torsion bar out. Loosen at buckle and then unhook buckle.

Adjust/rotate the TMT on extremity for ease of access to the torsion bar. Twist torsion bar until bleeding stops and the pulse is not present.

Lock the torsion bar into the retainer. Secure excess strap with VELCRO® Brand material.

Grip tail close to the buckle, firmly pull up, out, and away from the body and then downward in a quick ratcheting motion. Repeat step until snug around extremity.

Hold the end of the strap by the white Time label tab, allow the TMT to fall open with the word “PULL” facing away from you. Place around the injured extremity high and tight above the wound.

Pull ,me tab un,l VELCRO® Brand material is separated.

TACTICAL MECHANICAL TOURNIQUET

3 4TWIST LOCK

1

PN# 60064 Cage: 056F9

ONE-HANDED OPERATION INSTRUCTIONS

2WRAP PULL

While holding end of strap with white Time Label up, allow tourniquet to fall open. Place around injured extremity HIGH AND TIGHT above wound.

Pull strap until tight around limb and secure remaining strap length down on itself. Dual Locking Mechanism will maintain pressure when tourniquet is applied, evenif hook and loop is not completely secure.

Twist the torsion bar (tightening the band) until bright red bleeding stops and the distal pulse is non-palpable.

Lock the torsion bar into retainer. Ensure the torsion bar is secure before release of positive control. Secure excess strap length by wrapping over torsion bar providing additional security.

TO RELEASE: Maintain positive control. Lift retainer clip up and push torsion bar out, then unhook strap.

Limitation of liability: Alphapointe, its employees, agents, con-tractors, suppliers, and distributors shall assume no liability for in-jury or damages arising from the application and use of the TMT. The user assumes all risk liability. The TMT should only be used as directed in the military service component guidelines, EMS authority, or under direct supervision of a physician. Standard Use Guidelines: For life threatening hemorrhage situa-tions. For the military in the Care Under Fire situation, treatment normally consists of using a tourniquet immediately to stop ma-

and authorized rescuer will perform all treatment necessary us-ing the TMT as a last resort and should only be applied when bleeding cannot be stopped and the situation is life threatening.

Alphapointe3611 14th AvenueBrooklyn, NY 11218

FDA Registered This is a SINGLE USE device.

Always store in one-handed

“CLICK”

Made in U.S.A.

MECHANICAL TOURNIQUET

TACTICAL MECHANICAL TOURNIQUET

NSN: 6515-01-656-6191 Cage: 056F9 PN# 60064

FDA Registered Patent Pending

This is a SINGLE USE device ISO 9001:20008 Certi�ed

Alphapointe3611 14th AvenueBrooklyn, NY 11218 Made in U.S.A.

Always storein one-handed

Savior Global8 Ash GardensHamworthy, Poole, DorsetBH15 4DE United Kingdom

EC REP

TOURNIQUET

1 2

3 4

1

5

1 2 3

4 5 REMOVAL

GRIP PULL UP PULL DOWN

ADJUST TWIST

Grip tail close to the buckle, firmly pull up, out

Patent Pending

jor bleeding of the extremities. In field care situation, the trained

TACTICAL MECHANICAL

TOURNIQUETDistrbuted by:Combat Medical5555 Harrisburg Industrial Park DriveHarrisburg, NC 28075 USA1-855-428-6074www.combatmedicalsystems.com

31-115 | CMS-PUB-TMT-04-003

TM Alphapointe3611 14th AvenueBrooklyn, NY 11218 USACAGE Code: 056F9

Made in USAPat. Info: combatmedicalsystems.com/ipNSN: 6515-01-656-6191

V3

Limitation of liability: Alphapointe, its employees, agents, con-tractors, suppliers, and distributors shall assume no liability for injury or damages arising from the application and use of the TMT. ONLY use the TMT as directed in the instructions for use. Do not remove the slider from the strap. The user assumes all risk liability. It is recommended to receive appropriate first aid training.

ISO 9001:2015 Certified

Page 2: ONE-HANDED OPERATION INSTRUCTIONS 1 2 TWIST LOCK 3 4 1 ... · 3 4 1 TACTICAL MECHANICAL TOURNIQUET Cage: 056F9PN# 60064 Cage: 056F9PN# 60064 ONE-HANDED OPERATION INSTRUCTIONS 2 Limitation

3 4

1

TACTICAL MECHANICAL TOURNIQUET

Cage: 056F9 PN# 60064

ONE-HANDED OPERATION INSTRUCTIONS

2

Limitation of liability: Alphapointe, its employees, agents, con-tractors, suppliers, and distributors shall assume no liability for in-

The user assumes all risk liability. The TMT should only be used as directed in the military service component guidelines, EMS authority, or under direct supervision of a physician. Standard Use Guidelines: For life threatening hemorrhage situa-tions. For the military in the Care Under Fire situation, treatment normally consists of using a tourniquet immediately to stop ma-

-ing the TMT as a last resort and should only be applied when bleeding cannot be stopped and the situation is life threatening.

Alphapointe3611 14th AvenueBrooklyn, NY 11218

FDA Registered This is a SINGLE USE device. ISO 9001: 2008 Certified

TMTAlways store in one-handed con�guration.

Made in U.S.A.

Hold the end of the strap by the white time label tab, allow the TMT to fall open. Grab TMT by the buckle and separate the two sections.

Wrap/Feed the TMT around the injured extremity high and tight above the wound, ensuring device is not twisted. Reconnect the buckle.

Pull time tab until VELCRO® Brand material is separated.

up, out and away from the body and then downward in a quick ratcheting motion. Repeat step until snug around extremity.

Adjust/rotate the TMT on extremity for ease of access to the torsion bar. Twist torsion bar until bleeding stops and the pulse is not present.

NSN: 6515-01-656-6191

1 2 3

4 5

TWO-HANDED OPERATION INSTRUCTIONS

Lock the torsion bar into the retainer. Secure excess strap with VELCRO® Brand material.6

GRIP PULL UP PULL DOWN

ADJUST

“CLICK”

GRIP PULL UP PULL DOWN

ADJUST

“CLICK”

ADJUST

GRIP PULL UP PULL DOWN

“CLICK”

GRIP PULL UP PULL DOWN

ADJUST

“CLICK”

GRIP PULL UP PULL DOWN

ADJUST

“CLICK”

3 4

1

TACTICAL MECHANICAL TOURNIQUET

Cage: 056F9 PN# 60064

ONE-HANDED OPERATION INSTRUCTIONS

2

Limitation of liability: Alphapointe, its employees, agents, con-tractors, suppliers, and distributors shall assume no liability for in-

The user assumes all risk liability. The TMT should only be used as directed in the military service component guidelines, EMS authority, or under direct supervision of a physician. Standard Use Guidelines: For life threatening hemorrhage situa-tions. For the military in the Care Under Fire situation, treatment normally consists of using a tourniquet immediately to stop ma-

-ing the TMT as a last resort and should only be applied when bleeding cannot be stopped and the situation is life threatening.

Alphapointe3611 14th AvenueBrooklyn, NY 11218

FDA Registered This is a SINGLE USE device. ISO 9001: 2008 Certified

TMTAlways store in one-handed con�guration.

Made in U.S.A.

Hold the end of the strap by the white 3me label tab, allow the TMT to fall open. Grab TMT by the buckle and separate the two sec3ons. 1

4 �TWIST LOCK

1 PULL

TWO-HANDED OPERATION INSTRUCTIONS

2 3WRAP SNAP PULL

Wrap the TMT around the limb HIGH and TIGHT above wound site.

Snap the slider into receiving hook. Pull strap until tight around limb and secure additional strap length down on itself. Dual Locking Mechanism will maintain pressure when tourniquet is applied, even if hook and loop is not completely secure.

Twist the torsion bar (tightening the band) until bright red bleeding stops and the distal pulse is non-palpable.

Lock the torsion bar into retainer. Ensure the torsion bar is secure before release of positive control. Secure excess strap length by wrapping over torsion bar providing additional security.

TO RELEASE: Maintain positive control. Lift retainer clip up and push torsion bar out, then unhook strap.

TACTICAL MECHANICAL TOURNIQUET

PN# 60064 Cage: 056F9

FDA Registered This is a SINGLE USE device.

9 Line MEDEVAC RequestLine 1: Location of the pick-up site

Line 3: Number of patients by precedenceLine 4: Special equipment requiredLine �: Number of patientsLine 6: Security at pick-up siteLine �: Method of marking pick-up siteLine 8: Patient nationality and statusLine 9: NBC Contamination (Peacetime: Terrain)

“CLICK”

“CLICK”

Alphapointe3611 14th AvenueBrooklyn, NY 11218 Made in U.S.A.

MECHANICAL TOURNIQUET

TACTICAL MECHANICAL TOURNIQUET

NSN: 6515-01-656-6191 Cage: 056F9 PN# 60064

FDA Registered Patent Pending

This is a SINGLE USE device ISO 9001:20008 Certi�ed

Alphapointe3611 14th AvenueBrooklyn, NY 11218 Made in U.S.A.

TOURNIQUET

4 �TWIST LOCK

1 PULL

TWO-HANDED OPERATION INSTRUCTIONS

2 3WRAP SNAP PULL

Wrap the TMT around the limb HIGH and TIGHT above wound site.

Snap the slider into receiving hook. Pull strap until tight around limb and secure additional strap length down on itself. Dual Locking Mechanism will maintain pressure when tourniquet is applied, even if hook and loop is not completely secure.

Twist the torsion bar (tightening the band) until bright red bleeding stops and the distal pulse is non-palpable.

Lock the torsion bar into retainer. Ensure the torsion bar is secure before release of positive control. Secure excess strap length by wrapping over torsion bar providing additional security.

TO RELEASE: Maintain positive control. Lift retainer clip up and push torsion bar out, then unhook strap.

TACTICAL MECHANICAL TOURNIQUET

PN# 60064 Cage: 056F9

FDA Registered This is a SINGLE USE device.

9 Line MEDEVAC RequestLine 1: Location of the pick-up site

Line 3: Number of patients by precedenceLine 4: Special equipment requiredLine 5: Number of patientsLine 6: Security at pick-up siteLine 7: Method of marking pick-up siteLine 8: Patient nationality and statusLine 9: NBC Contamination (Peacetime: Terrain)

“CLICK”

“CLICK”

Alphapointe3611 14th AvenueBrooklyn, NY 11218 Made in U.S.A.

MECHANICAL TOURNIQUET

TACTICAL MECHANICAL TOURNIQUET

NSN: 6515-01-656-6191 Cage: 056F9 PN# 60064

FDA Registered Patent Pending

This is a SINGLE USE device ISO 9001:20008 Certi�ed

Alphapointe3611 14th AvenueBrooklyn, NY 11218 Made in U.S.A.

TOURNIQUET

Wrap/Feed the TMT around the injured extremity high and 3ght above the wound, ensuring device is not twisted. Reconnect the buckle. 2 Pull 3me tab un3l

VELCRO® Brand material is separated. 3

Grip tail close to the buckle, firmly pull up, out and away from the body and then downward in a quick ratche3ng mo3on. Repeat step un3l snug around extremity. 4 Adjust/rotate the TMT on extremity

for ease of access to the torsion bar. Twist torsion bar un3l bleeding stops and the pulse is not present. 5 Lock the torsion bar

into the retainer. Secure excess strap with VELCRO® Brand material.

6

Hold the end of the strap by the white 3me label tab, allow the TMT to fall open. Grab TMT by the buckle and separate the two sec3ons. 1

4 �TWIST LOCK

1 PULL

TWO-HANDED OPERATION INSTRUCTIONS

2 3WRAP SNAP PULL

Wrap the TMT around the limb HIGH and TIGHT above wound site.

Snap the slider into receiving hook. Pull strap until tight around limb and secure additional strap length down on itself. Dual Locking Mechanism will maintain pressure when tourniquet is applied, even if hook and loop is not completely secure.

Twist the torsion bar (tightening the band) until bright red bleeding stops and the distal pulse is non-palpable.

Lock the torsion bar into retainer. Ensure the torsion bar is secure before release of positive control. Secure excess strap length by wrapping over torsion bar providing additional security.

TO RELEASE: Maintain positive control. Lift retainer clip up and push torsion bar out, then unhook strap.

TACTICAL MECHANICAL TOURNIQUET

PN# 60064 Cage: 056F9

FDA Registered This is a SINGLE USE device.

9 Line MEDEVAC RequestLine 1: Location of the pick-up site

Line 3: Number of patients by precedenceLine 4: Special equipment requiredLine �: Number of patientsLine 6: Security at pick-up siteLine �: Method of marking pick-up siteLine 8: Patient nationality and statusLine 9: NBC Contamination (Peacetime: Terrain)

“CLICK”

“CLICK”

Alphapointe3611 14th AvenueBrooklyn, NY 11218 Made in U.S.A.

MECHANICAL TOURNIQUET

TACTICAL MECHANICAL TOURNIQUET

NSN: 6515-01-656-6191 Cage: 056F9 PN# 60064

FDA Registered Patent Pending

This is a SINGLE USE device ISO 9001:20008 Certi�ed

Alphapointe3611 14th AvenueBrooklyn, NY 11218 Made in U.S.A.

TOURNIQUET

4 �TWIST LOCK

1 PULL

TWO-HANDED OPERATION INSTRUCTIONS

2 3WRAP SNAP PULL

Wrap the TMT around the limb HIGH and TIGHT above wound site.

Snap the slider into receiving hook. Pull strap until tight around limb and secure additional strap length down on itself. Dual Locking Mechanism will maintain pressure when tourniquet is applied, even if hook and loop is not completely secure.

Twist the torsion bar (tightening the band) until bright red bleeding stops and the distal pulse is non-palpable.

Lock the torsion bar into retainer. Ensure the torsion bar is secure before release of positive control. Secure excess strap length by wrapping over torsion bar providing additional security.

TO RELEASE: Maintain positive control. Lift retainer clip up and push torsion bar out, then unhook strap.

TACTICAL MECHANICAL TOURNIQUET

PN# 60064 Cage: 056F9

FDA Registered This is a SINGLE USE device.

9 Line MEDEVAC RequestLine 1: Location of the pick-up site

Line 3: Number of patients by precedenceLine 4: Special equipment requiredLine �: Number of patientsLine 6: Security at pick-up siteLine �: Method of marking pick-up siteLine 8: Patient nationality and statusLine 9: NBC Contamination (Peacetime: Terrain)

“CLICK”

“CLICK”

Alphapointe3611 14th AvenueBrooklyn, NY 11218 Made in U.S.A.

MECHANICAL TOURNIQUET

TACTICAL MECHANICAL TOURNIQUET

NSN: 6515-01-656-6191 Cage: 056F9 PN# 60064

FDA Registered This is a SINGLE USE device Alphapointe3611 14th AvenueBrooklyn, NY 11218 Made in U.S.A.

TOURNIQUET

Wrap/Feed the TMT around the injured extremity high and 3ght above the wound, ensuring device is not twisted. Reconnect the buckle. 2 Pull 3me tab un3l

VELCRO® Brand material is separated. 3

Grip tail close to the buckle, firmly pull up, out and away from the body and then downward in a quick ratche3ng mo3on. Repeat step un3l snug around extremity. 4 Adjust/rotate the TMT on extremity

for ease of access to the torsion bar. Twist torsion bar un3l bleeding stops and the pulse is not present. 5 Lock the torsion bar

into the retainer. Secure excess strap with VELCRO® Brand material.

6 GRIP PULL UP PULL DOWN ADJUST TWIST

Grip tail close to the buckle, firmly pull

Line 2: Radio frequency, call sign, and suffix

Patent Pending ISO 9001:2008 Certified

TACTICAL MECHANICAL

TOURNIQUETDistrbuted by:Combat Medical5555 Harrisburg Industrial Park DriveHarrisburg, NC 28075 USA1-855-428-6074www.combatmedicalsystems.com

31-115 | CMS-PUB-TMT-04-003

TM Alphapointe3611 14th AvenueBrooklyn, NY 11218 USACAGE Code: 056F9

Made in USAPat. Info: combatmedicalsystems.com/ipNSN: 6515-01-656-6191

V3ISO 9001:2015 Certified