opc with profitrace - er-softadding opc tags save tag data when ready (also during operation) 1)...
TRANSCRIPT
PROCENTEC Product Support Copyright © 2010 PROCENTEC. All rights reservedOPC with ProfiTrace
PROCENTEC Product Support Copyright © 2010 PROCENTEC. All rights reserved
18 March 2010 2OPC with ProfiTrace
First install the OPC drivers
Y i t ll th d i th P fiT f ld iYou can install the driversdirectly from the file folders…..
….. or the ProfiTrace folder in the Start menu (easier!)
1) It takes a relatively long time to install the drivers!
PROCENTEC Product Support Copyright © 2010 PROCENTEC. All rights reserved
18 March 2010 3OPC with ProfiTrace
the drivers!
Select Setup OPC Tag Settings
Select Setup OPC Tag Settings
PROCENTEC Product Support Copyright © 2010 PROCENTEC. All rights reserved
18 March 2010 4OPC with ProfiTrace
Adding OPC TagsSave Tag Data when ready(also during operation)
1) Keep in mind that many Tags make the system slow To solve this you can filter Tagsthis you can filter Tags in the client you are using.
Adding a variable tagpointing to slave data
Tags which are already available(Live List, Statistics, etc.)
Confirm the
PROCENTEC Product Support Copyright © 2010 PROCENTEC. All rights reserved
18 March 2010 5
settings
OPC with ProfiTrace
Select Setup OPC server
Select Setup OPC Server
PROCENTEC Product Support Copyright © 2010 PROCENTEC. All rights reserved
18 March 2010 6OPC with ProfiTrace
Create an OPC Server1) Maximum 16 Servers
can be created each with its own Tag groups
Add a new OPC server
groups.
PROCENTEC Product Support Copyright © 2010 PROCENTEC. All rights reserved
18 March 2010 7OPC with ProfiTrace
Setting up the OPC Server
1. Give it a name or keep the default name
4. Confirm the settings
1) When multiple Servers are created, it is best that you work with Tag files (* PTO)
2. Connect it to a specific ProfiCore or any
with Tag files ( .PTO).
which is attached
3. File name with Tags orjust use the default Tags
Ready!
just use the default Tags
PROCENTEC Product Support Copyright © 2010 PROCENTEC. All rights reserved
18 March 2010 8OPC with ProfiTrace
OPC Server is now available
The Server can be modifiedduring operation
The Server is now available forexternal applications
Ready!
PROCENTEC Product Support Copyright © 2010 PROCENTEC. All rights reserved
18 March 2010 9OPC with ProfiTrace
PROCENTEC Product Support Copyright © 2010 PROCENTEC. All rights reserved
18 March 2010 10OPC with ProfiTrace
Connecting to the ProfiTrace OPC Server
1. Search/Add the OPC server
2. Connect withthe OPC server
3 Adding tags3. Adding tags
PROCENTEC Product Support Copyright © 2010 PROCENTEC. All rights reserved
18 March 2010OPC with ProfiTrace 11
Select ProfiTrace Tags
1. Untick this!!!
3. Add Tags here
2. Browse Tags2. Browse Tags
Ready!
PROCENTEC Product Support Copyright © 2010 PROCENTEC. All rights reserved
18 March 2010OPC with ProfiTrace 12
Exploring the Tags / Adding more Tags
Selected Tags
Add additional Tags
PROCENTEC Product Support Copyright © 2010 PROCENTEC. All rights reserved
18 March 2010OPC with ProfiTrace 13
PROCENTEC Product Support Copyright © 2010 PROCENTEC. All rights reserved
18 March 2010OPC with ProfiTrace 14