Open Path Eddy Covariance System With IRGASON or EC150/CSAT3A Quick Deploy Guide

March 2014

Page 2: Open Path Eddy Covariance System Quick Deploy …s.campbellsci.com/documents/br/manuals/opec-system-quick...Microsoft Word - Open Path Eddy Covariance System Quick Deploy Guide 3-5-14.docx

1. Setup tripod and mount enclosures.

Datalogger Enclosure 

EC100 Electronics 

Page 3: Open Path Eddy Covariance System Quick Deploy …s.campbellsci.com/documents/br/manuals/opec-system-quick...Microsoft Word - Open Path Eddy Covariance System Quick Deploy Guide 3-5-14.docx

2. Ground tripod and enclosures.

Ground Lug

Grounding Rod 

Page 4: Open Path Eddy Covariance System Quick Deploy …s.campbellsci.com/documents/br/manuals/opec-system-quick...Microsoft Word - Open Path Eddy Covariance System Quick Deploy Guide 3-5-14.docx

3. Setup tripod or mast with CM20X Crossarm.

Crossarm‐To‐Pole 

Bracket 

CM20X Crossarm

Page 5: Open Path Eddy Covariance System Quick Deploy …s.campbellsci.com/documents/br/manuals/opec-system-quick...Microsoft Word - Open Path Eddy Covariance System Quick Deploy Guide 3-5-14.docx

4. Mount the IRGASON or EC150/CSAT3A and point into the prevailing wind.

 

 

 

 

 

 

 

 

 

 

 

IRGASON

CM20X Crossarm  

IRGASON Boom 

Adapter 

IRGASON 

Mounting Bracket  Leveling 

Bubble 

EC150

CSAT3A

CSAT3A Boom 

Adapter 

CSAT3A Mounting 

Bracket 

OR

Leveling 

Bubble 

Page 6: Open Path Eddy Covariance System Quick Deploy …s.campbellsci.com/documents/br/manuals/opec-system-quick...Microsoft Word - Open Path Eddy Covariance System Quick Deploy Guide 3-5-14.docx

5. Mount the radiation shield and IRGASON or EC150/CSAT3A Temperature Probe. 

 

 

 

 

 

 

 

 

 

 

 

 

CM20X Crossarm  

Radiation Shield  

IRGASON or EC150/CSAT3A

Temperature Probe  

Page 7: Open Path Eddy Covariance System Quick Deploy …s.campbellsci.com/documents/br/manuals/opec-system-quick...Microsoft Word - Open Path Eddy Covariance System Quick Deploy Guide 3-5-14.docx

6. Connect gas analyzer, sonic anemometer, and temperature probe cables to EC100 Electronics.

Temperature Probe Cable 

Gas Analyzer Cable

Sonic Anemometer Cable

Page 8: Open Path Eddy Covariance System Quick Deploy …s.campbellsci.com/documents/br/manuals/opec-system-quick...Microsoft Word - Open Path Eddy Covariance System Quick Deploy Guide 3-5-14.docx

7. Connect system wiring and insert CompactFlash (CF) card.

Datalogger 

Enclosure 

EC100 Power and SDM Cables 

Insert CF card

Page 9: Open Path Eddy Covariance System Quick Deploy …s.campbellsci.com/documents/br/manuals/opec-system-quick...Microsoft Word - Open Path Eddy Covariance System Quick Deploy Guide 3-5-14.docx

SDM Cable 

Otherwise connect 

cable from +12 Vdc 

power supply here 

Power Cable 

Power Cable (can connect here or 

directly to +12 Vdc power supply) 

SDM Cable

If datalogger has 

rechargeable base, 

connect cable from 

+17‐28 Vdc or +18 Vac 

power supply here 

Page 10: Open Path Eddy Covariance System Quick Deploy …s.campbellsci.com/documents/br/manuals/opec-system-quick...Microsoft Word - Open Path Eddy Covariance System Quick Deploy Guide 3-5-14.docx

8. Turn on the power supply and use the datalogger keyboard display to set settings. (Follow the stepsfrom left to right, top to bottom).

System ControlSonic Azmth :0.00000Change Press Source > On Site Zero & Span > System Menu

Select “Sonic Azmth”.

Press <Esc> to activate the display. Press <Enter> to display the System Control Menu.

CampbellScientific

CR3000 Datalogger 01/01/2012, 14:00:08.4 CPU: OPEC_basic_vx_x.cr3 Running.

Page 11: Open Path Eddy Covariance System Quick Deploy …s.campbellsci.com/documents/br/manuals/opec-system-quick...Microsoft Word - Open Path Eddy Covariance System Quick Deploy Guide 3-5-14.docx

Modify Value NUM Sonic Azmth

Current Value: 0.00000 New Value: 150

Enter in the azimuth (the angle in degrees between true north and the direction the IRGASON or EC150/CSAT3A points), and press <ENTER>.

Press <Esc> to exit.

Campbell Scientific

CR3000 Datalogger 01/01/2012, 14:00:08.4 CPU: OPEC_basic_vx_x.cr3 Running.

Page 12: Open Path Eddy Covariance System Quick Deploy …s.campbellsci.com/documents/br/manuals/opec-system-quick...Microsoft Word - Open Path Eddy Covariance System Quick Deploy Guide 3-5-14.docx

Please visit www.campbellsci.com to obtain contact information for your local US or International representative.