Optics Optical Systems Free Space Isolators E-O Devices Spherical Singlets Multi-Element Lenses Cylindrical Lenses Aspheric Lenses Mirrors Diffusers & Lens Arrays Windows Prisms Gratings Polarization Optics Beamsplitters Filters & Attenuators Gas Cells 852 www.thorlabs.com Gas Reference Cells Overview Applications: Tunable Laser Calibration Stabilized Frequency Source OSA Calibration Gas Analyzer Calibration Calibration of Wavelength Meter Frequency Standards Gas reference cells, hereafter referred to as reference cells, are often used in applications where the wavelength of light needs to be accurately determined. Although spectrometers and optical spectrum analyzers are built specifically for this purpose, both need to be accurately calibrated in order to yield accurate absolute wavelength measurements. A reference cell consists of a cylindrical container (cell) containing a high purity molecular compound or atomic element. During the manufacturing of the reference cell, the temperature and pressure inside the cell are precisely regulated since these factors affect the reference cell performance. A reference cell can serve as an absolute wavelength calibration source because the reference cell will only absorb light at wavelengths that correspond to the allowed transitions between energy levels of the material inside the reference cell. For the materials offered in the reference cells sold by Thorlabs, the absorption lines (wavelengths of light that are absorbed) are well known. The absolute wavelength of the absorption lines can be found in peer reviewed journals and in some cases online at www.nist.gov. In order to reproduce the absorption lines reported by these sources, the temperature and contents of the reference cell need to be identical to the cell used in the reported measurement since changes in temperature, pressure, and material can cause shifts and/or broadening of the absorption lines. Reference Cell Contents The alkali atoms are located in the first column of the periodic table. Thorlabs offers alkali reference cells that contain sodium, potassium, rubidium, and cesium. In alkali atom reference cells, the bulk of the material in the cell will be coalesced in a solid or liquid form on the cell walls. However, since the cell was sealed with vacuum conditions inside the cell, alkali vapor will be present. The atomic vapor will absorb light with wavelengths corresponding to the allowed transitions between the energy levels of the atoms. When the reference cell is at room temperature, the light absorbed will be principally due to transitions between the ground state and excited electronic states of the atom. A reference cell that contains an alkali atom source is sometimes referred to as a vapor reference cell. Additional vapor reference cells offered by Thorlabs include cells with water or iodine as the source material. The iodine vapor forms the diatomic molecule I 2 . Water and iodine absorb light corresponding to transitions between rotational and/or vibrational energy levels in the molecule. In addition to vapor reference cells, cells that contain molecules that exist in the gaseous state at room temperature are available. When these reference cells are loaded with the molecular gas and sealed, the pressure and temperature are precisely controlled so that it is possible to reproduce the conditions, and as a result, the location of the absorption lines reported in literature. The molecular gas reference cells sold by Thorlabs include acetylene, hydrogen cyanide, carbon monoxide, carbon dioxide, nitrogen dioxide, methane, ethane, and ethylene. Each gas has a unique set of absorption lines corresponding to allowed transitions between rotational and vibrational energy levels. Due to the number of absorption lines in the NIR region of the electromagnetic spectrum, molecular gas reference cells make excellent calibration sources for light sources and test equipment used in the Telecom industry. The National Institute of Standards and Technology (NIST) have created wavelength reference standards for the Telecom industry based on Standard Reference Materials (SRM): 2515 (carbon monoxide), 2517a (acetylene), and 2519 (hydrogen cyanide). Reference Cell Containers Thorlabs’ reference cells are made from either Pyrex or quartz. Pyrex is an inexpensive material with good optical transmission characteristics. Between 350 and 2400nm, the transmission of Pyrex is over 92% as can be seen on the plot below. Pyrex is also durable in that it is less susceptible to breaking or chipping than quartz. Due to its chemical stability, 0 0 2 0 4 0 6 0 8 0 0 1 0 8 1 3 0 8 1 2 0 8 1 1 0 8 1 h t g n e l e v a W % Transmission x e r y P Cesium Absorption Lines at 852nm Typical saturated absorption experiment using a cesium reference cell that yields a plot of the Doppler-free Cs absorption line at 852nm.

Upload: lehanh

Post on 24-Jul-2018

225 views

Category:

Documents


0 download

TRANSCRIPT

Optics

Optical Systems

Free Space Isolators

E-O Devices

Spherical Singlets

Multi-ElementLenses

Cylindrical Lenses

Aspheric Lenses

Mirrors

Diffusers& Lens Arrays

Windows

Prisms

Gratings

Polarization Optics

Beamsplitters

Filters& Attenuators

Gas Cells

852 www.thorlabs.com

Gas Reference Cells Overview

Applications:■ Tunable Laser Calibration■ Stabilized Frequency Source■ OSA Calibration■ Gas Analyzer Calibration■ Calibration of Wavelength Meter■ Frequency Standards

Gas reference cells, hereafter referred to asreference cells, are often used inapplications where the wavelength of lightneeds to be accurately determined.Although spectrometers and opticalspectrum analyzers are built specifically forthis purpose, both need to be accuratelycalibrated in order to yield accurateabsolute wavelength measurements. Areference cell consists of a cylindricalcontainer (cell) containing a high puritymolecular compound or atomic element.During the manufacturing of the referencecell, the temperature and pressure insidethe cell are precisely regulated since thesefactors affect the reference cellperformance. A reference cell can serve as an absolutewavelength calibration source because thereference cell will only absorb light atwavelengths that correspond to theallowed transitions between energy levelsof the material inside the reference cell.For the materials offered in the reference

cells sold by Thorlabs, the absorption lines(wavelengths of light that are absorbed)are well known. The absolute wavelengthof the absorption lines can be found inpeer reviewed journals and in some casesonline at www.nist.gov. In order toreproduce the absorption lines reported bythese sources, the temperature andcontents of the reference cell need to beidentical to the cell used in the reportedmeasurement since changes intemperature, pressure, and material cancause shifts and/or broadening of theabsorption lines.Reference Cell Contents

The alkali atoms are located in the firstcolumn of the periodic table. Thorlabsoffers alkali reference cells that containsodium, potassium, rubidium, andcesium. In alkali atom reference cells, thebulk of the material in the cell will becoalesced in a solid or liquid form on thecell walls. However, since the cell wassealed with vacuum conditions inside thecell, alkali vapor will be present. Theatomic vapor will absorb light withwavelengths corresponding to the allowedtransitions between the energy levels ofthe atoms. When the reference cell is atroom temperature, the light absorbed willbe principally due to transitions betweenthe ground state and excited electronicstates of the atom. A reference cell thatcontains an alkali atom source issometimes referred to as a vapor referencecell. Additional vapor reference cells offered byThorlabs include cells with water oriodine as the source material. The iodinevapor forms the diatomic molecule I2.Water and iodine absorb lightcorresponding to transitions betweenrotational and/or vibrational energy levelsin the molecule. In addition to vapor reference cells, cellsthat contain molecules that exist in thegaseous state at room temperature are

available. When these reference cells areloaded with the molecular gas and sealed,the pressure and temperature are preciselycontrolled so that it is possible toreproduce the conditions, and as a result,the location of the absorption linesreported in literature. The molecular gasreference cells sold by Thorlabs includeacetylene, hydrogen cyanide, carbonmonoxide, carbon dioxide, nitrogendioxide, methane, ethane, and ethylene.Each gas has a unique set of absorptionlines corresponding to allowed transitionsbetween rotational and vibrational energylevels. Due to the number of absorption lines inthe NIR region of the electromagneticspectrum, molecular gas reference cellsmake excellent calibration sources for lightsources and test equipment used in theTelecom industry. The National Instituteof Standards and Technology (NIST) havecreated wavelength reference standards forthe Telecom industry based on StandardReference Materials (SRM): 2515 (carbonmonoxide), 2517a (acetylene), and 2519(hydrogen cyanide). Reference Cell ContainersThorlabs’ reference cells are made fromeither Pyrex or quartz. Pyrex is aninexpensive material with good opticaltransmission characteristics. Between 350and 2400nm, the transmission of Pyrex isover 92% as can be seen on the plotbelow. Pyrex is also durable in that it isless susceptible to breaking or chippingthan quartz. Due to its chemical stability,

0

02

04

06

08

001

081308120811081 htgnelevaW

% T

ran

smis

sio

n

xeryP

Cesium Absorption Lines at 852nm

Typical saturated absorption experiment using a cesium reference cell thatyields a plot of the Doppler-free Cs absorption line at 852nm.

18 Gas Cells 851-857.qxd.P 7/11/07 3:44 PM Page 852

853

Optics

Optical Systems

Free Space Isolators

E-O Devices

Spherical Singlets

Multi-ElementLenses

Cylindrical Lenses

Aspheric Lenses

Mirrors

Diffusers& Lens Arrays

Windows

Prisms

Gratings

Polarization Optics

Beamsplitters

Filters& Attenuators

Gas Cells

www.thorlabs.com

Pyrex Reference CellsThe quality Pyrex reference cells offered by Thorlabs have optical quality SchottBorofloat windows and are tested to ensure that the transmission of off resonant lightthrough the reference cell exceeds 84%. The transmission loss is primarily due tosurface reflections from the windows. The content of the reference cell is also tested bymeasuring the absorption spectra of a well known transition using a tunable diode laser.The following transitions are used for each reference cell: 764nm for potassium, 589nmfor sodium, 780nm for rubidium, and 852nm for cesium.

The standard reference cells are evacuated before the fill material is added and the cell issealed so that the fill material is the only material inside the cell. However, the referencecells can be ordered with the fill material and a buffer gas at a specified pressure. Thenoble gases as well as nitrogen are commonly used as buffer gases. The presence of abuffer gas will cause the central wavelength of the absorption lines to shift and thewidth of the absorption lines to broaden.

ITEM # $ £ € RMB PRESSURE DESCRIPTION

CP25075-RB $ 434.50 £ 273.70 € 404,10 ¥ 4,149.50 >1x10-7 Torr Ref. Cell, Pyrex Ø25 x 75mm, Rubidium (Rb)CP25075-CS $ 434.50 £ 273.70 € 404,10 ¥ 4,149.50 >1x10-7 Torr Ref. Cell, Pyrex Ø25 x 75mm, Cesium (Cs)CP25075-K $ 434.50 £ 273.70 € 404,10 ¥ 4,149.50 >1x10-7 Torr Ref. Cell, Pyrex Ø25 x 75mm, Potassium (K)CP25075-NA $ 434.50 £ 273.70 € 404,10 ¥ 4,149.50 >1x10-7 Torr Ref. Cell, Pyrex Ø25 x 75mm, Sodium (Na)

Specifications■ Window Material: Schott

Borofloat Glass■ Cell Diameter: 25mm■ Fill Stem: <10mm■ Window Angle: 0°■ Window Type: Flat■ Window Thickness: 3mm

Email tech support at [email protected] for custom reference cells.

Gas Reference Cells Overview… (cont)Pyrex is suitable for holding K, Na, Cs,and Rb. The standard sized Pyrex cell is25mm in diameter and 75mm in length.Quartz is a more expensive material withexcellent optical characteristics. The cell iscomposed of a cylindrical quartz tubewith UV fused silica (synthetic fusedquartz) windows on each end. The opticaltransmission plot for the UV fused silicacan be seen to the right. Notice that thetransmission range extends much fartherinto the UV than it does for Pyrex. Inaddition, the UV grade fused silicawindows have an optical flatness of λ/4for minimal wavefront distortion of thelight passing through the cell. Quartz has

a low coefficient of thermal expansion thatmakes it resilient to thermal shock. Thethermal properties as well as the welded

construction of the quartz cell make itsuitable for high-temperature applications(up to 850°C). The quartz cells are

constructed with windows that have a 2°wedge. In addition, the window is alsomounted at an angle with respect to thelength of the cell to minimize saturationand interference effects due to surfacereflections. The angled surfaces preventthe surface reflection from retracing thesame optical path as the incident light.Except for potassium and sodium, allother materials are available in a quartzreference cell. 0

02

04

06

08

001

081308120811081mn htgnelevaW

% T

ran

smis

sio

n

aciliS desuF

A tunable laser is used to scan the wavelength of light propagating through the Rb referencecell. The detector measures the intensity of the transmitted light as a function of wavelenth,and an oscilloscope records the output of the detector as a function of time. The plot showsthe Doppler broadened absorption spectrum of the D2 line of Rb.

18 Gas Cells 851-857.qxd.P 7/11/07 3:44 PM Page 853

Norm

aliz

ed T

rans

mitt

ance

Norm

aliz

ed T

rans

mitt

ance

Norm

aliz

ed T

rans

mitt

ance

Norm

aliz

ed T

rans

mitt

ance

Norm

aliz

ed T

rans

mitt

ance

Wavelength (nm)

Tran

smitt

ance

(dB)

855

Optics

Optical Systems

Free Space Isolators

E-O Devices

Spherical Singlets

Multi-ElementLenses

Cylindrical Lenses

Aspheric Lenses

Mirrors

Diffusers& Lens Arrays

Windows

Prisms

Gratings

Polarization Optics

Beamsplitters

Filters& Attenuators

Gas Cells

Molecular Gas Cells

www.thorlabs.com

The complex absorption line spectrum of the molecular gases offered by Thorlabsmake them excellent fill materials for reference cells used to calibrate the absolutewavelength of light over a range of wavelengths from 0.5-10µm. The multitude ofabsorption lines is a result of the large number of allowed transition between thevarious rotational and vibrational energy levels.

Due to the number of absorption lines in the NIR region of the electromagneticspectrum, molecular gas reference cells make excellent calibration sources for the lightsources and test equipment used in the Telecom industry. The National Institute ofStandards and Technology (NIST) have created wavelength reference standards for theTelecom industry based on Standard Reference Materials (SRM):2515 (carbonmonoxide), 2517a (Acetylene), and 2519 (hydrogen cyanide). In addition to thesegases, Thorlabs also sells molecular gas reference cells with carbon dioxide, nitrogendioxide, methane, ethane, and ethylene.

ITEM # $ £ € RMB PRESSURE DESCRIPTION

CQ09050-CH12 $ 434.50 £ 273.70 € 404,10 ¥ 4,149.50 50Torr Ref. Cell, Quartz Ø9 x 50mm, Acetylene (12C2H2)CQ09050-CH13 $ 434.50 £ 273.70 € 404,10 ¥ 4,149.50 50Torr Ref. Cell, Quartz Ø9 x 50mm, Acetylene (13C2H2)CQ09075-HCN13 $ 434.50 £ 273.70 € 404,10 ¥ 4,149.50 100Torr Ref. Cell, Quartz Ø9 x 75mm, Hydrogen Cyanide (H13C14N)CQ09150-CO12 $ 434.50 £ 273.70 € 404,10 ¥ 4,149.50 600Torr Ref. Cell, Quartz Ø9 x 150mm, Carbon Monoxide (12C16O)CQ09150-CO13 $ 434.50 £ 273.70 € 404,10 ¥ 4,149.50 600Torr Ref. Cell, Quartz Ø9 x 150mm, Carbon Monoxide (13C16O)CQ09150-CO2 $ 434.50 £ 273.70 € 404,10 ¥ 4,149.50 200Torr Ref. Cell, Quartz Ø9 x 150mm, Carbon Dioxide (CO2)CQ09150-NO2 $ 434.50 £ 273.70 € 404,10 ¥ 4,149.50 400Torr Ref. Cell, Quartz Ø9 x 150mm, Nitrogen Dioxide (NO2)CQ09075-CH4 $ 434.50 £ 273.70 € 404,10 ¥ 4,149.50 200Torr Ref. Cell, Quartz Ø9 x 75mm, Methane (CH4)CQ09075-C2H6 $ 434.50 £ 273.70 € 404,10 ¥ 4,149.50 200Torr Ref. Cell, Quartz Ø9 x 75mm, Ethane (C2H6)CQ09075-C2H4 $ 434.50 £ 273.70 € 404,10 ¥ 4,149.50 200Torr Ref. Cell, Quartz Ø9 x 75mm, Ethylene (C2H4)

Custom molecular gas reference cells areavailable by request. For example, reference cellscan be created with a mixture of gases atdifferent pressures to create a calibration sourcewith absorption lines in more than one spectralregion. A plot is shown below of the absorptionspectrum of a cell that contains a mixture ofacetylene and methane gas. This cell hasabsorption lines from 1510-1545nm due toacetylene as well as absorption lines from 1630-1670nm due to methane. Other common gasmixtures used include HCN and carbonmonoxide (12C16O), or HCN and carbonmonoxide (13C16O).

HCN Absorption Spectrum Carbon Monoxide Isotope 12 Absortion Spectrum Methane-Acetylene Mixture Absorption Spectrum

Acetylene Isotope 13 Absorption Spectrum Methane Absorption Spectrum Carbon Monoxide Isotope 13 Absorption Spectrum

18 Gas Cells 851-857.qxd.P 7/11/07 3:44 PM Page 855