outdoor cables - prysmian group · 1 gbe dist (m) 10 gbe dist (m) g6 = om1 (62.5μm) 850/1300...

114
Telecom Solutions Outdoor Cables 2018 Telecom Catalog – Outdoor Cables_v1 2018

Upload: others

Post on 19-May-2020

5 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

Telecom SolutionsOutdoor Cables

2018 Telecom Catalog – Outdoor Cables_v1

2018

Page 2: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF
Page 3: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

INTRO & OVERVIEW ..................................................... 4-13

OUTDOOR - Ordering Guide ........................................14-15

• LOOSE TUBE / CENTRAL TUBEExpressLT™ (dry)........................................................16-19ExpressLT™ (gel) ......................................................20-23LT 2.0 (gel) ...............................................................24-27LT 2.0 (dry) ............................................................... 28-31CentraLink™ CD .......................................................32-33CentraLink™ Double Armored .................................34-35ezMICROUNITUBE™ ................................................36-37ExpressLT™ All Dielectric Armored .......................... 38-39

• RIBBONFusionLink™ RICT (gel) ............................................40-41FusionLink™ RICT Amored (gel) .............................. 42-43Dry FusionLink™ RICT ............................................. 44-45Dry FusionLink™ RICT Armored .............................. 46-47MassLink™ .............................................................. 48-49MassLink™ 1728 ....................................................... 50-51

• FLEXRIBBONMini FlexTube ..........................................................52-53

• DROPCentral LT 300 ..........................................................54-55ResiLink™ ADF Flat Drop Dielectric ..........................56-57ResiLink™ TF Flat Drop Toneable ............................ 58-59Toneable Round Drop ..............................................60-61ezDrop™ Figure-8 .....................................................62-63ResiLink™ Universal Service Drop ........................... 64-65ezMICROUNITUBE ...................................................66-67

TABLE OF CONTENTS

• MICRODUCTezMICRODUCT™ ..................................................... 68-69

• FIGURE-8AeroLink™ Figure-8 ...................................................70-71AeroLink™ Figure-8, Armored .................................. 72-73

• ADSSezSPAN® ADSS ........................................................74-83Long Span ADSS ......................................................84-91

• TOOLSBuffer Tube Slitter ...................................................92-93ezTOOLS™ Buffer Tube Midspan Access Tool ......... 94-95

• FLAME RATED (FR) CABLE INTRO .......................96-97

INDOOR - Ordering Guide ................................... 98-99

INDOOR/OUTDOOR - Ordering Guide ............. 100-101

SPECIALTY - Ordering Guide ............................102-103

• ADDITIONAL RESOURCESFiber Code Addendum ................................................ 104Pre-Ordering Guide ..................................................... 105Color Codes ...........................................................106-107Excess Fiber Lengths for OTDR Setup ................. 108-109Wooden Reel Table ............................................... 110-113

Page 4: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

4

Vision

The Prysmian Group believesin the effective, efficientand sustainable supplyof Energy and Informationas a primary driverin the developmentof communities

Mission

The Prysmian Group providesits customers worldwidewith superior cable solutionsbased on pioneering technologyand consistent excellence inexecution, ultimately deliveringsustainable growth and profit.

Values

ExcellenceEvery day we relentlessly purseexcellence in all we do

UnderstandingWe listen closely to our customersto really understand their needs

IntegrityWe uphold the highest standardsof integrity in our actions

Prysmian Group

Market, innovation and technology leader in the global cables industry.

Prysmian Group is world leader in the energy and telecom cables and systems industry. With

more than 130 years of experience, sales in excess of 7.9 billion dollars in 2017, over 21,000

employees in 50 countries and 88 production sites, the Group offers the widest possible range of

products, services, technology and know-how for every type of industry thanks to an extensive

commercial presence and 17 R&D centers in Europe, the United States, South America and China,

with more than 500 qualified R&D professionals.

Prysmian is a public company, listed on the Italian Stock Exchange in the FTSE MIB index.

PRYSMIAN GROUPVISION, MISSION, VALUES

Page 5: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

5

PRODUCT PORTFOLIO: PRODUCT PORTFOLIO: PRODUCT PORTFOLIO:

TELECOMSOLUTIONS

CABLING SOLUTIONSused fortelecommunicationnetworks

PRODUCTION AND DEVELOPMENTof optical fiber

OPTIC ALFIBER

ACCESS & SPECIALT YSOLUTIONS

CABLING SOLUTIONSfor communication needs in premise, industrial, wireless and transport infrastructures

PRODUCT PORTFOLIO:

- Single-Mode Fiber

- Multimode Fiber

- Specialty Fiber

PRODUCT PORTFOLIO:

- Riser

- Plenum

- LSZH (Low Smoke Zero Halogen)

- Interlock Armor

- Copper/Fiber Hybrid

- Harsh Environment

PRODUCT PORTFOLIO:

- Loose Tube

- Ribbon

- Drop

- ADSS

- OPGW

- Tight Buffer

PRODUCTS

Page 6: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

6

OUR STRENGTHS

World leader in the energy & telecom cables andsystems industry, partner of the world’s key players

WIDE RANGE OF PRODUCTS, SERVICES, TECHNOLOGIES

STRONG POSITION IN HIGH TECH SECTORS

Page 7: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

7

OWNERSHIP

PRYSMIAN GROUP IS A PUBLIC COMPANY

A listed company without a controlling shareholder, managed on a transparent basis and leveraging its ability to gain and maintain the continued confidence of its investors.

OWNERSHIP STRUCTURE BY MAIN INVESTORS

OWNERSHIP STRUCTURE

BY GEOGRAPHY3%Ireland

3%Switzerland

4%Germany

10%Rest ofEurope 2%

Hong KongChina

14%Italy

26%UK

22%US

10%France

2%Rest ofthe world

4%Norway

77.8%Institutional

Investors

217.5MILLIONSHARES

10.9%Other

8.3%Retail

3%Treasuryshares

3%Ireland

3%Switzerland

4%Germany

10%Rest ofEurope 2%

Hong KongChina

14%Italy

26%UK

22%US

10%France

2%Rest ofthe world

4%Norway

77.8%Institutional

Investors

217.5MILLIONSHARES

10.9%Other

8.3%Retail

3%Treasuryshares

Page 8: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

8

NORTHAMERICA

9PLANTS

SOUTHAMERICA

7PLANTS

APAC

18PLANTS

50 Countries

88 Plants

17 R&D Centers

19,000 Employees

GLOBAL PRESENCEEMEA

Ivory CoastAbidjan

DenmarkBrøndby

EstoniaKeila

FinlandPikkalaOulu

FranceAmfrevilleAngyCharvieuChavanozGronNeuf PréParonXoulcesDouvrinCalaisSainte Genevieve

GermanyNeustadtSchwerinNurembergWuppertalBerlin

ItalyArco FeliceBattipagliaGiovinazzoLivornoMerlinoPignataro MaggioreQuattordio

NorwayDrammen

OmanMuscatSohar

NetherlandsEindhovenDelftAmsterdamEmmenDelfzijlNieuw-Bergen

Czech RepublicVelké Meziříčí

RomaniaSlatina

RussiaRybinsk

SlovakiaPrešov

SpainVilanova y la GeltrúSantanderSanta Perpètua

SwedenNässjö

TunisiaGrombalia

TurkeyMudanya

UAEFujairah

UKAberdareBishopstokeWrexhamWashington

HungaryBalassagyarmatKistelek

South America

ArgentinaLa RosaQuilmes

BrasilJoinvilleSorocaba (2)Santo AndréVila Velha

APAC

AustraliaDee WhyLiverpool

ChinaBaoyingTianjinWuxiWuhanHaixanShanghaiSuzhouZhongyao

PhilippinesCebu

IndiaPuneChiplun

IndonesiaCicampek

MayalsiaKuala LumpurMelacca

New ZealandAuckland

ThailandRayong

North America

CanadaPrescott

MexicoDurango

USAAbbevilleLexingtonNorth DightonBridgewaterRocky MountClaremontSchuylkill Haven

Headquarters

O§ces

Energy

Telecom

Combined Energy & Telecom

EMEA

54PLANTS

Page 9: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

9

NORTHAMERICA

9PLANTS

SOUTHAMERICA

7PLANTS

APAC

18PLANTS

50 Countries

88 Plants

17 R&D Centers

19,000 Employees

GLOBAL PRESENCEEMEA

Ivory CoastAbidjan

DenmarkBrøndby

EstoniaKeila

FinlandPikkalaOulu

FranceAmfrevilleAngyCharvieuChavanozGronNeuf PréParonXoulcesDouvrinCalaisSainte Genevieve

GermanyNeustadtSchwerinNurembergWuppertalBerlin

ItalyArco FeliceBattipagliaGiovinazzoLivornoMerlinoPignataro MaggioreQuattordio

NorwayDrammen

OmanMuscatSohar

NetherlandsEindhovenDelftAmsterdamEmmenDelfzijlNieuw-Bergen

Czech RepublicVelké Meziříčí

RomaniaSlatina

RussiaRybinsk

SlovakiaPrešov

SpainVilanova y la GeltrúSantanderSanta Perpètua

SwedenNässjö

TunisiaGrombalia

TurkeyMudanya

UAEFujairah

UKAberdareBishopstokeWrexhamWashington

HungaryBalassagyarmatKistelek

South America

ArgentinaLa RosaQuilmes

BrasilJoinvilleSorocaba (2)Santo AndréVila Velha

APAC

AustraliaDee WhyLiverpool

ChinaBaoyingTianjinWuxiWuhanHaixanShanghaiSuzhouZhongyao

PhilippinesCebu

IndiaPuneChiplun

IndonesiaCicampek

MayalsiaKuala LumpurMelacca

New ZealandAuckland

ThailandRayong

North America

CanadaPrescott

MexicoDurango

USAAbbevilleLexingtonNorth DightonBridgewaterRocky MountClaremontSchuylkill Haven

Headquarters

O§ces

Energy

Telecom

Combined Energy & Telecom

EMEA

54PLANTS

Page 10: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

10

MARKETS

Page 11: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

11

MARKETS

Page 12: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

12

1.2 Million Square Foot Campus

Fiber Manufacturing, Cable Manufacturing, Research & Development

TL9000, ISO 9001, ISO 14001 and ISO 17025 Certified

- 10 plants in North America serving the telecom and energy markets.

- Offers over 100,000 designs of indoor, indoor-outdoor, outdoor and specialty fiber optic cable.

- Two fiber optic manufacturing facilities in the United States covering 1.5 million square feet, including the only co-located fiber and cable facility in North America.

Claremont, NC Facility

Page 13: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

13

300,000 Square Foot Campus

TL9000, ISO 9001, ISO 14001 and ISO 17025 Certified

Fiber Cable Manufacturing

Research & Development

North American Headquarters for Telecom & Energy Divisions

- Best in class rating for many of the TL 9000 categories.

- The highest level of certifications in the industry: ISO 9001, ISO 14001, ISO 17025, ISO TS 16949, IRIS and TL9000 certified.

- Drives change and innovation while constantly connecting with our customers to help them respond to challenges more efficiently.

- Expanded our product and service offer in terms of products, brands and technologies.

- 17 research and development centers in ten countries and 5,000 patents granted or filed.

- As a combined company, our greater reach, range and service enables us to meet or exceed customer requirements.

Certified

Lexington, SC Facility

Page 14: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

14

ORDERING GUIDE - OUTDOOR

F EDH 1A1J 12 HB 072 E3

2 PRODUCT FAMILY 3 CONSTRUCTION 4 FIBER

GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADELENGTH MARKINGS1

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

PART NUMBER CONTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

REFER to OUTDOOR PRODUCT TABLE

3 CONTRUCTION

1JKT = Single Jacket

1A1J = Single Armor, Single Jacket

1A2J = Single Armor, Dual Jacket

2A2J = Double Armor, Dual Jacket

2A3J = Double Armor, Triple Jacket

NA2J = Non Armored, Dual Jacket

NATJ = Non Armored, Toneable (used with flat drop)

4 FIBER GROUPING

12 = 12f per unit or tube

24 = 24f per unit or tube

36 = 36f per unit or tube

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 C & D)

CE = Corning™ SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & G.652.D)

BB = BendBright™ Single-Mode (ITU G.657.A1 & G.652.D)

CU = Corning™ Ultra Single-Mode (ITU G.657.A1 & G.652.D)

BX = BendBrightXS™ Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

TU = TeraLight™ Ultra Single-Mode (ITU G.655 & G.656)

LE = LEAF NZDSF (ITU G.655)

MULTIMODEWavelength

(mm)Bandwidth

(MHz)1 GbE

Dist (m)10 GbE

Dist (m)

G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___

G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___

G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___

G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___

6 FIBER COUNT

004 TO 1728 fibers

7 FIBER GRADE

SINGLE-MODE MULTIMODE

Attenuation (dB/km) Wavelength (nm) Fiber Type Attenuation (dB/km) Wavelength (nm)

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, or CE M2 = 3.5/1.0 850/1300

E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, CE, B1, BB, CU or BX M3 = 3.0/1.0 850/1300

NA = 0.40/0.25 1310/1550 TeraLight Ultra Single-ModeOther cable constructions and fiber performance grades available.

N1 = 0.25 1550 NZDSF Single-Mode

The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance.The appropriate part number can be configured using the process described below:

Example: ExpressLT gel-free | single armor single Jacket (12f/tube) with 72 single-mode fibers 0.35/0.35/0.25 dB/Km @ 1310/1383/1550 (printed in feet)

Page 15: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

15

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2018 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued June 2018.

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

2 PRODUCT FAMILY

LOOSE TUBE

EDH 2 to 432f ExpressLT™ (12f per tube) Dry

ETH 2 to 432f ExpressLT™ (12f per tube) Gel-Tubes

E2G 2 to 456f LT 2.0™ Gel-Tubes

E2D 2 to 456f LT 2.0™ Dry

E3H 2 to 288f ExtremeLink™ Gel-Tubes

EAH 2 to 288f ExtremeLink™ Dry

CL6 2 to 12f CentraLink™ CD Gel-Tube

D6H 2 to 12f CentraLink™ CD Dry

C6H 2 to 12f CentraLink™ CD Double Armor Gel-Tube

E23 2 to 12f LT 2.0™ 300 N/A

E24 2 to 12f LT 2.0™ 300 Gel-Tube

FXT 12 to 288f Mini FlexTube® Gel

RIBBON

RCG 12 to 864f FusionLink™ RICT Gel-Tube

RCD60 to 432f,612 to 864f

FusionLink™ RICT (Coupled Design) Dry

RCU 12 to 48, 576f FusionLink™ RICT (Uncoupled Design) Dry

RLG 288 to 864f MassLink™ (12f ribbons) Gel-Tubes

RLG 1296 to 1728f MassLink™ (12 & 24f ribbons) Gel-Tubes

DROP

DFD 1 to 12f ResiLink™ Flat Drop Dielectric or Toneable

DF8 1 to 6f Figure-8 3/32” Messenger

CL6 1 to 12f CentraLink™ CD Gel-Tube

C3H 1 or 12f CentralLT™ 300 without ripcords Gel-Tube

C3R 1 or 12f CentralLT™ 300 with ripcords Gel-Tube

D3H 1 or 12f CentralLT™ 300 without ripcords Dry

D3R 1 or 12f CentralLT™ 300 with ripcords Dry

UMH 2 to 24f MicroUnitube™ (12f bundles) Gel-Tube

MICROPRODUCT

MDS 2 to 144f ezMICRODUCT™ (12f bundles) Gel-Tubes

MDS 108 to 144f ezMICRODUCT™ (24f bundles) Gel-Tubes

MD1 2 to 60f ezMICRODUCT™ 100 Gel-Tubes

MDM 144, 288f ezMICRODUCT™ (1.5mm Tube, BIF) Gel-Tubes

MDM 96 to 144f ezMICRODUCT™ (2.2mm, 24f per Tube, BIF) Gel-Tubes

FIGURE-8

F8A 2 to 216f Loose Tube Figure-8, 1/4” Messenger Gel-Tubes

F8D 2 to 216f Loose Tube Figure-8, 1/4” Messenger Dry

ADSS

ADE 2 to 144f ezSPAN™ ADSS Gel-Tubes

ADF 2 to 144f ezSPAN™ ADSS Dry

ADL 2 to 432f Long Span™ ADSS Gel-Tubes

Note: See the data sheet since a different part number configuration is used.

Page 16: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

16

500A

DS0

16 E

XPR

ESSL

T D

RY

04-1

7

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

ExpressLT™ DryDry loose tube cable (2.5 mm)

MANUFACTURED IN

Outer Strength Members (where applicable)Dry Buffer Tube Containing up to 12 Fibers

Water Blocking TapeMDPE Inner Jacket (Double Jacket Designs Only)

MDPE Outer Jacket

Central Strength Member

ezPREP® Corrugated Steel Armor (optional)Ripcord

A versatile, multi-purpose fiber cable designed for ease of use and buffer tube mid-span storage applications OverviewPrysmian’s popular ExpressLT™ cable combines buffer tubes with enhanced flexibility, a completely dry water-blocking system, and optional ezPREP® armor. The buffer tubes are also rated for mid-span storage applications. This combination of features makes ExpressLT™ an ideal solution for applications requiring frequent sheath access and express tube storage. Product Snapshot Applications Multi-purpose outdoor, aerial lashed, duct, direct buried (when armored) Constructions Dielectric, armored, double armored, dual jacket Count 4 to 432 fibers in color-coded buffer tubes Fiber Types Single-mode, multimode, bend-insensitive SM, NZDS Options Steel central member, 22 or 24 AWG copper pair(s), 16 AWG tonewire, striped Jacket, factory-installed pulling eye Similar Gel-filled buffer tubes / LT 2.0 / heavy duty / Alternatives central / indoor-outdoor / indoor / self-support / microduct Performance Tested in accordance with TIA 455 series FOTPs for fiber optic cables. Complies with ICEA 640, RUS 7 CFR 1755 (PE90 listed), Telcordia GR-20, and IEC 60794-3-11 Registered ISO 9001, ISO 14001, TL 9000, Supplier and OHSAS 18001

Features and Benefits Easy Cable Entry and Preparation

- Dry water-blocked core speeds cable access

- Dry water-blocked tubes reduce prep time by an average of 15 minutes per cable end - Available with ezPREP® armor to allow easy access to the core in mid-sheath entries - Reverse oscillating stranded core facilitates mid-span access of fibers. Tubes can easily be removed from the core - Ripcord speeds cable entry & outer jacket removal Available with ezPREP® Armor

- The jacket can be easily separated from the armor without a heat gun or torch - Armored cable access, bonding and grounding are faster, easier and safer Flexible Routing and Termination

- Buffer tubes can be stored in FTTx pedestals, closures and cabinets in lengths up to 20' - 2.5 mm buffer tubes with enhanced flexibility simplify routing and splice preparation

Multi-Purpose Design

- Suitable for aerial lashed, duct, and direct buried installation (when armored) - Small diameter and light weight, extends reel and installation lengths - Optional ezPREP® corrugated steel tape armor provides mechanical protection and rodent resistance

RUSLISTED

LOO

SE T

UB

E /

CEN

TRA

L TU

BE

Page 17: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

17

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

16 E

XPR

ESSL

T D

RY

04-1

7

ExpressLT™ DryDry loose tube cable (2.5 mm)

Dielectric (Non-Armored) (EDH1JKT)

Fiber Count# of Buffer

TubesDiameter

Inches (mm)Approximate Cable Weight

lb/kft (kg/km)Bend Radius | Load

Inches (cm)Bend Radius | No Load

inches (cm)

4 to 60 5 0.40 (10.1) 43 (64) 8 (20) 4 (10)

62 to 72 6 0.43 (10.9) 50 (75) 8 (22) 4 (11)

74 to 96 8 0.50 (12.6) 65 (97) 10 (25) 5 (13)

98 to 120 10 0.55 (14.1) 81 (121) 11 (28) 6 (14)

122 to 144 12 0.63 (15.9) 105 (156) 13 (32) 6 (16)

146 to 216 18 0.63 (15.9) 105 (156) 13 (32) 6 (16)

228 to 264 22 0.68 (17.3) 128 (190) 14 (35) 7 (17)

276 to 288 24 0.72 (18.3) 145 (216) 14 (37) 7 (18)

290 to 432 36 0.80 (20.4) 154 (229) 16 (41) 8 (21)

Single Jacket Armored (SP) (EDH1A1J)

Fiber Count# of Buffer

TubesDiameter

Inches (mm)Approximate Cable Weight

lb/kft (kg/km)Bend Radius | Load

Inches (cm)Bend Radius | No Load

inches (cm)

4 to 60 5 0.46 (11.8) 89 (132) 9 (24) 5 (12)

62 to 72 6 0.50 (12.6) 97 (145) 10 (25) 5 (13)

74 to 96 8 0.56 (14.3) 125 (186) 11 (29) 6 (14)

98 to 120 10 0.62 (15.8) 148 (220) 12 (32) 6 (16)

122 to 144 12 0.69 (17.6) 176 (262) 14 (35) 7 (18)

146 to 216 18 0.70 (17.9) 176 (262) 14 (36) 7 (18)

228 to 264 22 0.76 (19.4) 196 (291) 15 (39) 8 (19)

276 to 288 24 0.81 (20.7) 214 (319) 16 (42) 8 (21)

290 to 432 36 0.90 (23.0) 230 (342) 18 (46) 9 (23)

Double Jacket Single Armored (PSP) (EDH1A2J)

Fiber Count# of Buffer

TubesDiameter

Inches (mm)Approximate Cable Weight

lb/kft (kg/km)Bend Radius | Load

Inches (cm)Bend Radius | No Load

inches (cm)

4 to 60 5 0.53 (13.5) 107 (160) 11 (27) 5 (14)

62 to 72 6 0.55 (14.0) 122 (181) 11 (28) 5 (14)

74 to 96 8 0.61 (15.5) 137 (204) 12 (31) 6 (16)

98 to 120 10 0.67 (17.1) 167 (249) 13 (34) 7 (17)

122 to 144 12 0.74 (18.9) 198 (294) 15 (38) 7 (19)

146 to 216 18 0.76 (19.2) 198 (294) 15 (38) 8 (19)

228 to 264 22 0.80 (20.4) 220 (327) 16 (41) 8 (20)

276 to 288 24 0.86 (21.8) 239 (356) 17 (44) 9 (22)

290 to 432 36 0.94 (24.0) 257 (382) 19 (48) 9 (24)

Temperature RangeShipping and Storage: -40o F to +167o F (-40o C to +75o C)Installation: -22o F to +140o F (-30o C to +60o C)Operation: -40o F to +158o F (-40o C to +70o C)

InstallationMaximum installation load: 600 lbf (2700 N)Maximum operation load: 180 lbf (800 N)

LOO

SE TUB

E / CENTR

AL TU

BE

Page 18: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

18

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

16 E

XPR

ESSL

T D

RY

04-1

7

ExpressLT™ DryDry loose tube cable (2.5 mm)

Temperature RangeShipping and Storage: -40o F to +167o F (-40o C to +75o C)Installation: -22o F to +140o F (-30o C to +60o C)Operation: -40o F to +158o F (-40o C to +70o C)

InstallationMaximum installation load: 600 lbf (2700 N)Maximum operation load: 180 lbf (800 N)

Dielectric Double Jacket (PDP) (EDHNA2J)

Fiber Count# of Buffer

TubesDiameter

Inches (mm)Approximate Cable Weight

lb/kft (kg/km)Bend Radius | Load

Inches (cm)Bend Radius | No Load

inches (cm)

4 to 60 5 0.46 (11.7) 63 (96) 9 (23) 5 (12)

62 to 72 6 0.48 (12.2) 73 (108) 10 (25) 5 (12)

74 to 96 8 0.54 (13.8) 89 (133) 11 (28) 5 (14)

98 to 120 10 0.61 (15.4) 111 (165) 12 (31) 6 (15)

122 to 144 12 0.67 (17.1) 133 (198) 13 (34) 7 (17)

146 to 216 18 0.67 (17.1) 137 (204) 13 (34) 7 (17)

218 to 264 22 0.74 (18.7) 159 (237) 15 (37) 7 (19)

266 to 288 24 0.78 (19.8) 179 (266) 16 (40) 8 (20)

Double Jacket Double Armored (SPSP) (EDH2A2J)

Fiber Count# of Buffer

TubesDiameter

Inches (mm)Approximate Cable Weight

lb/kft (kg/km)Bend Radius | Load

Inches (cm)Bend Radius | No Load

inches (cm)

4 to 60 5 0.64 (16.3) 182 (272) 13 (33) 6 (16)

62 to 72 6 0.67 (17.1) 194 (289) 13 (34) 7 (17)

74 to 96 8 0.75 (19.1) 226 (336) 15 (38) 8 (19)

98 to 120 10 0.80 (20.4) 258 (384) 16 (41) 8 (20)

122 to 144 12 0.88 (22.4) 312 (465) 18 (45) 9 (22)

146 to 216 18 0.88 (22.4) 305 (454) 18 (45) 9 (22)

218 to 264 22 0.94 (23.9) 338 (503) 19 (48) 9 (24)

266 to 288 24 0.98 (24.9) 368 (547) 20 (50) 10 (25)

Triple Jacket Double Armored (PSPSP) (EDH2A3J)

Fiber Count# of Buffer

TubesDiameter

Inches (mm)Approximate Cable Weight

lb/kft (kg/km)Bend Radius | Load

Inches (cm)Bend Radius | No Load

inches (cm)

4 to 60 5 0.70 (17.8) 215 (320) 14 (36) 7 (18)

62 to 72 6 0.73 (18.6) 228 (339) 15 (37) 7 (19)

74 to 96 8 0.78 (19.9) 265 (394) 16 (40) 8 (20)

98 to 120 10 0.86 (21.9) 313 (466) 17 (43) 9 (22)

122 to 144 12 0.93 (23.7) 367 (546) 19 (47) 9 (24)

146 to 216 18 0.93 (23.7) 367 (546) 19 (47) 9 (24)

218 to 264 22 0.98 (25.0) 402 (598) 20 (50) 10 (25)

266 to 288 24 1.02 (26.0) 429 (639) 20 (52) 10 (26)

LOO

SE T

UB

E /

CEN

TRA

L TU

BE

Page 19: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

19

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

16 E

XPR

ESSL

T D

RY

04-1

7

Ordering Guide

The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2017 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued April 2017.

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

EDH = ExpressLT™ Dry

3 CONSTRUCTION

1JKT = Single Jacket

1A1J = Single Armor, Single Jacket

1A2J = Single Armor, Dual Jacket

2A2J = Double Armor, Dual Jacket

2A3J = Double Armor, Triple Jacket

NA2J = Non Armored, Dual Jacket

4 FIBER GROUPING

12 = 12f per tube

F EDH 1A1J 12 HB 072 E3

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 C & D)

CE = Corning™ SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

TU = TeraLight Ultra Single-Mode (ITU G.655 & G.656)

LE = LEAF NZDSF (ITU G.655)

MULTIMODE Wavelength Bandwidth 1 GbE 10 GbE (nm) (MHz) Dist (m) Dist (m)

G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___

G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___

G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___

G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___

6 FIBER COUNT

004 to 432 fibers

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, or CE

E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, CE, B1, or B2

NA = 0.40/0.25 1310/1550 TeraLight Ultra Single-Mode

N1 = 0.25 1550 LE

MULTIMODE Attenuation (dB/km) Wavelength (nm)

M2 = 3.5/1.0 850/1300

M3 = 3.0/1.0 850/1300

Other cable constructions and fiber performance grades available on request.

1

Example: ExpressLT™ dry (gel-free) | single armor single jacket (12 fibers/tube) with 72 single-mode fibers (printed in feet)

LOO

SE TUB

E / CENTR

AL TU

BE

Page 20: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

20

LOO

SE T

UB

E /

CEN

TRA

L TU

BE

500A

DS0

15 E

XPR

ESSL

T G

EL 0

1-17

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

ExpressLT™ GelGel-filled loose tube cable (2.5mm)

MANUFACTURED IN

Outer Strength Members (where applicable)

Gel-Filled Buffer Tube Containing up to 12 Fibers

Water Blocking Tape

MDPE Inner Jacket (Double Jacket Designs Only)

MDPE Outer Jacket

Central Strength Member

ezPREP® Corrugated Steel Armor (optional)

Ripcord

A versatile, multipurpose fiber cable designed for ease of use and buffer tube mid-span storage applications OverviewPrysmian’s popular ExpressLT™ cable combines gel-filled buffer tubes with enhanced flexibility, a dry water-blocked core, and optional ezPREP® armor. The buffer tubes are also rated for mid-span storage applications. This combination of features makes ExpressLT™ an ideal solution for applications requiring frequent sheath access and express tube storage. Product Snapshot Applications Multi-purpose outdoor, aerial lashed, duct, direct buried (when armored) Constructions Dielectric, armored, double armored, dual jacket Count 4 to 432 fibers in color-coded buffer tubes Fiber Types Single-mode, multimode, bend-insensitive, NZDS Options Steel central member, 22 or 24 AWG copper pair(s), 16 AWG tonewire, striped jacket, factory-installed pulling eye Similar Dry buffer tubes / LT 2.0 / heavy duty Alternatives central / indoor-outdoor / indoor / self-support / microduct Performance Tested in accordance with TIA 455 series FOTPs for fiber optic cables. Complies with ICEA 640, RUS 7 CFR 1755 (PE90 listed), Telcordia GR-20, and IEC 60794-3-11

Registered ISO 9001, ISO 14001, TL 9000, Supplier and OHSAS 18001

Features and Benefits Easy Cable Entry and Preparation

- Dry water-blocked core speeds cable access - Available with ezPREP® armor to allow easy access to the core in mid-sheath entries - Reverse oscillating stranded core facilitates mid-span access of fibers. Tubes can easily be removed from the core - Ripcord speeds cable entry & outer jacket removal Available with ezPREP® Armor

- The jacket can be easily separated from the armor without a heat gun or torch - Armored cable access, bonding and grounding are faster, easier and safer Flexible Routing and Termination

- Buffer tubes can be stored in FTTx pedestals, closures and cabinets in lengths up to 20' - 2.5 mm buffer tubes with enhanced flexibility simplify routing & splice preparation

Multi-Purpose Design

- Suitable for aerial lashed, duct, and direct buried installation (when armored) - Small diameter and light weight, extends reel and installation lengths - Proven water-blocking with swellable core elements and gel-filled buffer tubes - Optional ezPREP® corrugated steel tape armor provides mechanical protection and rodent resistance

RUSLISTED

Page 21: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

21

LOO

SE TUB

E / CENTR

AL TU

BE

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

15 E

XPR

ESSL

T G

EL 0

1-17

ExpressLT™ Gel Gel-filled loose tube cable (2.5 mm)

Dielectric (Non-Armored) (ETH1JKT)

Fiber Count# of Buffer

TubesDiameter

inches (mm)Approximate Cable Weight

lb/kft (kg/km)Bend Radius | Load

inches (cm)Bend Radius | No Load

inches (cm)

4 to 60 5 0.40 (10.1) 46 (69) 8 (20) 4 (10)

62 to 72 6 0.43 (10.9) 55 (81) 8 (22) 4 (11)

74 to 96 8 0.50 (12.6) 71 (105) 10 (25) 5 (13)

98 to 120 10 0.55 (14.1) 88 (131) 11 (28) 6 (14)

122 to 144 12 0.63 (15.9) 117 (174) 13 (32) 6 (16)

146 to 216 18 0.63 (15.9) 120 (179) 13 (32) 6 (16)

218 to 264 22 0.68 (17.3) 143 (212) 14 (35) 7 (17)

266 to 288 24 0.72 (18.3) 162 (240) 14 (37) 7 (18)

290 to 432 36 0.80 (20.4) 188 (281) 16 (41) 8 (21)

Single Jacket Armored (SP) (ETH1A1J)

Fiber Count# of Buffer

TubesDiameter

inches (mm)Approximate Cable Weight

lb/kft (kg/km)Bend Radius | Load

inches (cm)Bend Radius | No Load

inches (cm)

4 to 60 5 0.46 (11.8) 92 (137) 9 (24) 5 (12)

62 to 72 6 0.50 (12.6) 101 (151) 10 (25) 5 (13)

74 to 96 8 0.56 (14.3) 130 (194) 11 (29) 6 (14)

98 to 120 10 0.62 (15.8) 155 (230) 12 (32) 6 (16)

122 to 144 12 0.69 (17.6) 188 (280) 14 (35) 7 (18)

146 to 216 18 0.70 (17.9) 188 (280) 14 (36) 7 (18)

218 to 264 22 0.76 (19.4) 210 (313) 15 (39) 8 (19)

266 to 288 24 0.81 (20.7) 230 (343) 16 (42) 8 (21)

290 to 432 36 0.90 (23.0) 277 (385) 18 (46) 9 (23)

Double Jacket Armored (PSP) (ETH1A2J)

Fiber Count# of Buffer

TubesDiameter

inches (mm)Approximate Cable Weight

lb/kft (kg/km)Bend Radius | Load

inches (cm)Bend Radius | No Load

inches (cm)

4 to 60 5 0.53 (13.5) 111 (165) 11 (27) 5 (14)

62 to 72 6 0.55 (14.0) 126 (187) 11 (28) 5 (14)

74 to 96 8 0.61 (15.5) 143 (212) 12 (31) 6 (16)

98 to 120 10 0.67 (17.1) 174 (259) 13 (34) 7 (17)

122 to 144 12 0.74 (18.9) 210 (312) 15 (38) 7 (19)

146 to 216 18 0.76 (19.2) 210 (312) 15 (38) 8 (19)

218 to 264 22 0.80 (20.4) 235 (349) 16 (41) 8 (20)

266 to 288 24 0.86 (21.9) 255 (380) 17 (44) 9 (22)

290 to 432 36 0.94 (24.0) 285 (424) 19 (48) 9 (24)

Temperature RangeShipping and Storage: -40o F to +167o F (-40o C to +75o C)Installation: -22o F to +140o F (-30o C to +60o C)Operation: -40o F to +158o F (-40o C to +70o C)

InstallationMaximum installation load: 600 lbf (2670 N)Maximum operation load: 180 lbf (800 N)

Page 22: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

22

LOO

SE T

UB

E /

CEN

TRA

L TU

BE

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

15 E

XPR

ESSL

T G

EL 0

1-17

ExpressLT™ Gel Gel-filled loose tube cable (2.5 mm)

Temperature RangeShipping and Storage: -40o F to +167o F (-40o C to +75o C)Installation: -22o F to +140o F (-30o C to +60o C)Operation: -40o F to +158o F (-40o C to +70o C)

InstallationMaximum installation load: 600 lbf (2670 N)Maximum operation load: 180 lbf (800 N)

Dielectric Double Jacket (PDP) (ETHNA2J)

Fiber Count# of Buffer

TubesDiameter

inches (mm)Approximate Cable Weight

lb/kft (kg/km)Bend Radius | Load

Inches (cm)Bend Radius | No Load

Inches (cm)

4 to 60 5 0.46 (11.7) 68 (101) 9 (23) 5 (12)

62 to 72 6 0.48 (12.2) 78 (116) 10 (25) 5 (12)

74 to 96 8 0.54 (13.8) 97 (144) 11 (28) 5 (14)

98 to 120 10 0.61 (15.4) 121 (180) 12 (31) 6 (15)

122 to 144 12 0.67 (17.1) 145 (216) 13 (34) 7 (17)

146 to 216 18 0.67 (17.1) 154 (228) 13 (34) 7 (17)

218 to 264 22 0.74 (18.7) 179 (266) 15 (37) 7 (19)

266 to 288 24 0.78 (19.8) 200 (298) 16 (40) 8 (20)

Double Jacket Double Armored (SPSP) (ETH2A2J)

Fiber Count# of Buffer

TubesDiameter

inches (mm)Approximate Cable Weight

lb/kft (kg/km)Bend Radius | Load

Inches (cm)Bend Radius | No Load

Inches (cm)

4 to 60 5 0.64 (16.3) 186 (277) 13 (33) 6 (16)

62 to 72 6 0.67 (17.1) 198 (295) 13 (34) 7 (17)

74 to 96 8 0.75 (19.1) 231 (344) 15 (38) 8 (19)

98 to 120 10 0.80 (20.4) 265 (394) 16 (41) 8 (20)

122 to 144 12 0.88 (22.4) 325 (483) 18 (45) 9 (22)

146 to 216 18 0.88 (22.4) 317 (472) 18 (45) 9 (22)

218 to 264 22 0.94 (23.9) 353 (525) 19 (48) 9 (24)

266 to 288 24 0.98 (24.9) 384 (571) 20 (50) 10 (25)

Triple Jacket Double Armored (PSPSP) (ETH2A3J)

Fiber Count# of Buffer

TubesDiameter

inches (mm)Approximate Cable Weight

lb/kft (kg/km)Bend Radius | Load

Inches (cm)Bend Radius | No Load

Inches (cm)

4 to 60 5 0.70 (17.8) 218 (325) 14 (36) 7 (18)

62 to 72 6 0.73 (18.6) 232 (345) 15 (37) 7 (19)

74 to 96 8 0.79 (20.1) 270 (402) 16 (40) 8 (20)

98 to 120 10 0.86 (21.9) 320 (476) 17 (43) 9 (22)

122 to 144 12 0.83 (23.7) 379 (564) 19 (47) 9 (24)

146 to 216 18 0.93 (23.7) 379 (564) 19 (47) 9 (24)

218 to 264 22 0.98 (25.0) 417 (620) 20 (50) 10 (25)

266 to 288 24 1.02 (26.0) 446 (663) 20 (52) 10 (26)

Page 23: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

23

LOO

SE TUB

E / CENTR

AL TU

BE

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

15 E

XPR

ESSL

T G

EL 0

1-17

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2017 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued January 2017.

Ordering Guide

The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

ETH = ExpressLT™ Gel-Filled Tubes

3 CONSTRUCTION

1JKT = Single Jacket

1A1J = Single Armor, Single Jacket

1A2J = Single Armor, Dual Jacket

2A2J = Double Armor, Dual Jacket

2A3J = Double Armor, Triple Jacket

NA2J = Non Armored, Dual Jacket

4 FIBER GROUPING

12 = 12f per tube

F ETH 1A1J 12 HB 072 E3

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 C & D)

CE = Corning™ SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

TU = TeraLight Ultra Single-Mode (ITU G.655 & G.656)

LE = LEAF NZDSF (ITU G.655

MULTIMODE Wavelength Bandwidth 1 GbE 10 GbE (nm) (MHz) Dist (m) Dist (m)

G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___

G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___

G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___

G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___

6 FIBER COUNT

004 to 432 fibers

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, or CE

E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, CE, B1, or B2

NA = 0.40/0.25 1310/1550 TeraLight Ultra Single-Mode

N1 = 0.25 1550 LEAF Single-Mode

MULTIMODE Attenuation (dB/km) Wavelength (nm)

M2 = 3.5/1.0 850/1300

M3 = 3.0/1.0 850/1300

Other cable constructions and fiber performance grades available on request.

Example: ExpressLT™ gel-filled, single armor single jacket (12 fibers/tube) with 72 single-mode fibers (printed in feet)

1

Page 24: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

24

LOO

SE T

UB

E /

CEN

TRA

L TU

BE

500A

DS0

19A

LT

2.0

08-1

7

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

LT 2.0 with Bend Insensitive FiberGel loose tube cable

MANUFACTURED IN

ezPrep® Corrugated Steel Armor (optional)

2.0 mm Buffer Tube (gel-filled)

MDPE Outer Jacket

Water Blocking Tape

Ripcord

Central Strength Member

Compact multi-purpose fiber cable; robust performance with simple loose tube access and preparation Overview

A compact, bend-optimized solution for the outside plant, LT 2.0 is a multi-purpose loose tube cable offering up to a 10% to 20% reduction in diameter depending on the design and up to 30% reduction in weight while meeting or exceeding RUS/RDUP and GR20 industry standards. This product platform utilizes bend-insensitive single-mode fiber to deliver superior bending tolerance and cold temperature performance. Product Snapshot Applications Multi-purpose outdoor - aerial lashed, duct, direct buried Constructions Dielectric, armored, double armored, dual Jacket (armored designs) Fiber Count 4 to 456 fibers in color-coded buffer tubes Fiber Types G657.A1 or A2 bend-insensitive single-mode Options Dry buffer tubes Other Versions Loose tube with 2.5 buffer tubes for indoor, outdoor, indoor-outdoor applications Performance ICEA 640, RUS 7 CFR 1755, Telcordia GR-20 and IEC 60794-3-11 Registered ISO 9001, ISO 14001, TL 9000, Supplier and OHSAS 18001

Features and Benefits Up to 20% Smaller Than Standard Loose Tube Cable - Counts up to 456 can be placed in a 1-inch duct - Smaller, less-expensive duct can be used - Can be placed into occupied ducts

Improved Reel Capacities - Up to 40% more cable on a reel - Longer lengths can be installed from the same reel or, smaller, lighter reels can be used - Saves money on storage & overcomes pay-off limitations

Up to 30% Lighter Than Standard Loose Tube Cable - Easier to handle during installation - Less load on aerial structures - Further reduces total weight (reel + cable)

Smaller Cable Bend Radius - Easier to install in tight spaces - Allows use of smaller pedestals and hand-holes

RDUP/RUS PE90 Compliant Cable and Buffer Tube - Up to 20 feet of tube can be stored in closures

Smaller Buffer Tube Bend Radius - Flexible 2.0 mm tube is highly kink-resistant - Can be stored in a 20 mm radius with G657.A2 fiber - More tube can be stored in a small space - Allows use of smaller splice trays and closures

Bend-Insensitive Fiber - ITU G657.A1 fiber is rated for bends down to 10 mm - ITU G657.A2 fiber is rated for bends down to 7.5 mm - Fully compliant to G.652.D SSMF specs

Improved Cable Entry and Preparation - ezPREP® armor greatly improves mid-sheath cable entry - Dual ripcords speed armored cable entry and outer jacket removal - Dry core design speeds cable preparation

RUSLISTED

Page 25: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

25

LOO

SE TUB

E / CENTR

AL TU

BE

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

19A

LT

2.0

08-1

7

LT 2.0 with Bend-Insensitive FiberGel loose tube cable

All-Dielectric (Non-Armored) Gel Tube (E2G1JKT)

Fiber Count # of Buffer Tubes

Diameterinches (mm)

Approximate Cable Weight

lb/kft (kg/km)

Bend Radius Load

inches (cm)

Bend Radius No Load

inches (cm)

4 to 72 6 0.37 (9.5) 45 (67) 8 (19) 4 (10)

74 to 84 7 0.40 (10.3) 52 (78) 8 (21) 4 (10)

86 to 96 8 0.42 (10.6) 56 (83) 8 (21) 4 (11)

98 to 108 9 0.42 (10.7) 57 (85) 8 (21) 5 (11)

110 to 120 10 0.45 (11.5) 66 (98) 9 (23) 5 (12)

122 to 132 11 0.48 (12.2) 74 (110) 10 (24) 5 (12)

134 to 144 12 0.50 (12.7) 81 (120) 10 (25) 5 (13)

156 to 216 18 0.53 (13.4) 87 (130) 11 (27) 5 (13)

228 to 264 22 0.56 (14.1) 99 (147) 11 (28) 6 (14)

276 to 288 24 0.58 (14.7) 108 (160) 12 (29) 6 (15)

290 to 456 38 0.70 (17.8) 156 (233) 14 (35) 7 (18)

Single Jacket Armored (SP) Gel Tube (E2G1A1J)

Fiber Count # of Buffer Tubes

Diameterinches (mm)

Approximate Cable Weight

lb/kft (kg/km)

Bend Radius Load

inches (cm)

Bend Radius No Load

inches (cm)

4 to 72 6 0.44 (11.2) 90 (133) 9 (22) 4 (11)

74 to 84 7 0.47 (12.0) 102 (151) 9 (24) 5 (12)

86 to 96 8 0.48 (12.2) 107 (159) 10 (24) 5 (12)

98 to 108 9 0.51 (13.0) 118 (175) 10 (26) 5 (13)

110 to 120 10 0.54 (13.8) 131 (195) 11 (28) 5 (14)

122 to 132 11 0.56 (14.3) 140 (209) 11 (29) 6 (14)

134 to 144 12 0.58 (14.8) 152 (227) 12 (30) 6 (15)

156 to 216 18 0.58 (14.8) 152 (227) 12 (30) 6 (15)

228 to 264 22 0.64 (16.3) 172 (257) 13 (33) 6 (16)

276 to 288 24 0.66 (16.8) 181 (269) 14 (35) 7 (17)

290 to 456 38 0.76 (19.4) 226 (337) 15 (39) 8 (19)

Double Jacket Single Armored (PSP) Gel Tube (E2G1A2J)

Fiber Count # of Buffer Tubes

Diameterinches (mm)

Approximate Cable Weight

lb/kft (kg/km)

Bend Radius Load

inches (cm)

Bend Radius No Load

inches (cm)

4 to 72 6 0.49 (12.5) 104 (156) 10 (25) 5 (13)

74 to 84 7 0.51 (13.0) 111 (165) 10 (26) 5 (13)

86 to 96 8 0.52 (13.3) 116 (173) 10 (27) 5 (13)

98 to 108 9 0.55 (14.0) 128 (190) 11 (28) 6 (14)

110 to 120 10 0.58 (14.8) 141 (210) 12 (30) 6 (15)

122 to 132 11 0.60 (15.3) 150 (223) 12 (31) 6 (15)

134 to 144 12 0.62 (15.8) 159 (237) 12 (32) 6 (16)

156 to 216 18 0.63 (16.1) 163 (243) 13 (32) 6 (16)

228 to 264 22 0.68 (17.3) 185 (275) 14 (35) 7 (17)

276 to 288 24 0.72 (18.3) 194 (288) 14 (36) 7 (18)

290 to 456 36 0.82 (20.9) 253 (377) 16 (42) 8 (21)

Page 26: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

26

LOO

SE T

UB

E /

CEN

TRA

L TU

BE

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

19A

LT

2.0

08-1

7

LT 2.0 with Bend-Insensitive FiberGel loose tube cable

Dielectric Double Jacket (PDP) Gel Tube (E2GNA2J)

Fiber Count # of Buffer Tubes

Diameterinches (mm)

Approximate Cable Weight

lb/kft (kg/km)

Bend Radius Load

inches (cm)

Bend Radius No Load

inches (cm)

4 to 72 6 0.42 (10.8) 58 (86) 8 (22) 4 (11)

74 to 84 7 0.45 (11.5) 66 (98) 9 (23) 5 (12)

86 to 96 8 0.47 (12.0) 71 (105) 9 (24) 5 (12)

98 to 108 9 0.50 (12.6) 79 (118) 10 (25) 5 (13)

110 to 120 10 0.52 (13.3) 87 (130) 10 (27) 5 (13)

122 to 132 11 0.55 (14.0) 97 (144) 11 (28) 5 (14)

134 to 144 12 0.57 (14.5) 105 (156) 11 (29) 6 (15)

156 to 216 18 0.57 (14.5) 105 (156) 11 (29) 6 (15)

218 to 264 22 0.63 (15.9) 125 (186) 13 (32) 6 (16)

266 to 288 24 0.65 (16.5) 135 (202) 13 (33) 7 (17)

Double Jacket Double Armored (SPSP) Gel Tube (E2G2A2J)

Fiber Count # of Buffer Tubes

Diameterinches (mm)

Approximate Cable Weight

lb/kft (kg/km)

Bend Radius Load

inches (cm)

Bend Radius No Load

inches (cm)

4 to 72 6 0.63 (16.1) 182 (270) 13 (32) 6 (16)

74 to 84 7 0.66 (16.8) 201 (299) 13 (34) 7 (17)

86 to 96 8 0.67 (17.1) 209 (310) 13 (34) 7 (17)

98 to 108 9 0.70 (17.8) 225 (335) 14 (36) 7 (18)

110 to 120 10 0.73 (18.6) 246 (365) 15 (37) 7 (19)

122 to 132 11 0.75 (19.1) 262 (390) 15 (38) 8 (19)

134 to 144 12 0.77 (19.6) 278 (414) 15 (39) 8 (20)

134 to 216 18 0.77 (19.6) 275 (409) 15 (39) 8 (20)

218 to 264 22 0.83 (21.1) 306 (455) 17 (42) 8 (21)

266 to 288 24 0.85 (21.6) 320 (476) 17 (43) 9 (22)

Triple Jacket Double Armored (PSPSP) Gel Tube (E2G2A3J)

Fiber Count # of Buffer Tubes

Diameterinches (mm)

Approximate Cable Weight

lb/kft (kg/km)

Bend Radius Load

inches (cm)

Bend Radius No Load

inches (cm)

4 to 72 6 0.68 (17.3) 206 (307) 14 (35) 7 (17)

74 to 84 7 0.70 (17.8) 215 (320) 14 (36) 7 (18)

86 to 96 8 0.71 (18.1) 226 (337) 14 (36) 7 (18)

98 to 108 9 0.74 (18.9) 244 (362) 15 (38) 7 (19)

110 to 120 10 0.77 (19.6) 261 (385) 15 (39) 8 (20)

122 to 132 11 0.79 (20.1) 275 (409) 16 (40) 8 (20)

134 to 144 12 0.81 (20.6) 285 (424) 16 (41) 8 (21)

146 to 216 18 0.82 (20.9) 290 (432) 16 (42) 8 (21)

218 to 264 22 0.87 (22.2) 321 (478) 17 (44) 9 (22)

266 to 288 24 0.91 (23.2) 332 (494) 18 (45) 9 (23)

Temperature RangeShipping and Storage: -40o F to +167o F (-40o C to +75o C)Installation: -22o F to +140o F (-30o C to +60o C)Operation: -40o F to +158o F (-40o C to +70o C)

Tensile RatingMaximum installation load: 600 lbf (2700 N)Maximum operation load: 180 lbf (800 N)

Page 27: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

27

LOO

SE TUB

E / CENTR

AL TU

BE

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

19A

LT

2.0

08-1

7

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2017 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued August 2017.

Ordering Guide

The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance.The appropriate part number can be configured using the process described below.

F E2G 1A1J 12 B1 072 E3

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

E2G = LT 2.0 | Gel Tube

3 CONSTRUCTION

1JKT = Single Jacket

1A1J = Single Armor, Single Jacket

1A2J = Single Armor, Dual Jacket

2A2J = Double Armor, Dual Jacket

2A3J = Double Armor, Triple Jacket

NA2J = Non Armored, Dual Jacket

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE

Example: LT 2.0 gel | single armor, single jacket (12 fibers/tube) with 72 G657.A1 bend insensitive fibers (printed in feet)

FIBER INFORMATION

4 FIBER GROUPING

12 = 12f per tube

5 FIBER TYPE

SINGLE-MODE

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

BX = BendBrightXS Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

6 FIBER COUNT

004 to 456 fibers

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm)

E3 = 0.35/0.35/0.25 dB/km 1310/1383/1550 nm

Other cable constructions & fiber performance grades available on request.

1

Page 28: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

28

LOO

SE T

UB

E /

CEN

TRA

L TU

BE

500A

DS0

19B

LT

2.0

DR

Y 08

-17

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

LT 2.0 with Bend-Insensitive FiberDry loose tube cable

MANUFACTURED IN

Compact multi-purpose fiber cable that has a robust performance with simple loose tube preparation and access.

Overview

A compact, bend-optimized solution for the outside plant, LT2.0 is a multi-purpose loose tube cable offering a 10% to 20% reduction in diameter depending on the design and up to 30% reduction in weight while meeting or exceeding RUS/RDUP and GR20 industry standards This product platform utilizes ITU G657.A2 bend-insensitive single-mode fiber to deliver superior bending tolerance and cold temperature performance. Product Snapshot Applications Multi-purpose outdoor - aerial lashed, duct, direct buried Constructions Dielectric, armored, double armored, dual Jacket (armored designs) Fiber Count 4 to 456 fibers in color-coded buffer tubes Fiber Types G657.A2 bend-insensitive single-mode Options Gel buffer tubes Other Versions Loose tube with 2.5 buffer tubes for indoor, outdoor, or indoor-outdoor applications Performance ICEA 640, RUS 7 CFR 1755, Telcordia GR-20, and IEC 60794-3-11 Registered ISO 9001, ISO 14001, TL 9000, Supplier and OHSAS 18001

Features and Benefits Up to 20% Smaller Than Standard Loose Tube cable - Counts up to 456 can be placed in a 1-inch duct - Smaller, less-expensive duct can be used - Can be placed into occupied ducts

Improved reel capacities - Up to 40% more cable on a reel - Longer lengths can be installed from the same reel or smaller, lighter reels can be used - Saves money on storage & overcomes pay-off limitations

Up to 30% Lighter Than Standard Loose Tube Cable - Easier to handle during installation - Less load on aerial structures - Further reduces total weight (reel + cable)

Smaller Cable Bend Radius - Easier to install in tight spaces - Allows use of smaller pedestals and hand-holes

RDUP/RUS PE90 Compliant Cable and Buffer Tube - Up to 20 feet of tube can be stored in closures

Smaller Buffer Tube Bend Radius - Flexible 2.0 mm tube is highly kink-resistant - Can be stored in a 20 mm radius - More tube can be stored in a small space - Allows use of smaller splice trays and closures

Bend-Insensitive Fiber - ITU G657.A2 fiber is rated for bends down to 7.5 mm - Fully compliant to G.652.D SSMF specs - Complies with G.657.A2

Improved Cable Entry and Preparation - Dry option simplifies access and clean-up - ezPREP® armor greatly improves mid-sheath cable entry - Dual ripcords speed armored cable entry and outer jacket removal - Dry core design speeds cable preparation

ezPrep® Corrugated Steel Armor (optional)

2.0 mm Dry Buffer Tube

MDPE Outer Jacket

Water Blocking Tape

Ripcord

Central Strength Member

RUSLISTED

Page 29: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

29

LOO

SE TUB

E / CENTR

AL TU

BE

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

19B

LT

2.0

DR

Y 08

-17

LT 2.0 with Bend-Insensitive Fiber Dry loose tube cable

All-Dielectric (Non-Armored) Dry (E2D1JKT)

Fiber Count # of Buffer Tubes

Diameterinches (mm)

Approximate Cable Weight

lb/kft (kg/km)

Bend Radius Load

inches (cm)

Bend Radius No Load

inches (cm)

4 to 72 6 0.37 (9.5) 41 (61) 8 (19) 4 (10)

74 to 84 7 0.40 (10.3) 48 (71) 8 (21) 4 (10)

86 to 96 8 0.42 (10.6) 50 (75) 8 (21) 4 (11)

98 to 108 9 0.42 (10.7) 52 (77) 8 (21) 5 (11)

110 to 120 10 0.45 (11.5) 59 (88) 9 (23) 5 (12)

122 to 132 11 0.48 (12.2) 66 (99) 10 (24) 5 (12)

134 to 144 12 0.50 (12.7) 73 (108) 10 (25) 5 (13)

156 to 216 18 0.53 (13.4) 75 (112) 11 (27) 5 (13)

228 to 264 22 0.56 (14.1) 84 (125) 11 (28) 6 (14)

276 to 288 24 0.58 (14.7) 92 (136) 12 (29) 6 (15)

290 to 456 38 0.70 (17.8) 130 (194) 14 (35) 7 (18)

Single Jacket Armored (SP) Dry (E2D1A1J)

Fiber Count # of Buffer Tubes

Diameterinches (mm)

Approximate Cable Weight

lb/kft (kg/km)

Bend Radius Load

inches (cm)

Bend Radius No Load

inches (cm)

4 to 72 6 0.44 (11.2) 85 (127) 9 (22) 4 (11)

74 to 84 7 0.47 (12.0) 97 (144) 9 (24) 5 (12)

86 to 96 8 0.48 (12.2) 101 (151) 10 (24) 5 (12)

98 to 108 9 0.51 (13.0) 112 (166) 10 (26) 5 (13)

110 to 120 10 0.54 (13.8) 124 (185) 11 (28) 5 (14)

122 to 132 11 0.56 (14.3) 133 (198) 11 (29) 6 (14)

134 to 144 12 0.58 (14.8) 144 (215) 12 (30) 6 (15)

156 to 216 18 0.58 (14.8) 137 (204) 12 (30) 6 (15)

228 to 264 22 0.64 (16.3) 158 (235) 13 (33) 6 (16)

276 to 288 24 0.66 (16.8) 165 (245) 14 (35) 7 (17)

290 to 456 38 0.76 (19.4) 201 (299) 15 (39) 8 (19)

Double Jacket Single Armored (PSP) Dry (E2D1A2J)

Fiber Count # of Buffer Tubes

Diameterinches (mm)

Approximate Cable Weight

lb/kft (kg/km)

Bend Radius Load

inches (cm)

Bend Radius No Load

inches (cm)

4 to 72 6 0.49 (12.5) 100 (150) 10 (25) 5 (13)

74 to 84 7 0.51 (13.0) 106 (158) 10 (26) 5 (13)

86 to 96 8 0.52 (13.3) 111 (165) 10 (27) 5 (13)

98 to 108 9 0.55 (14.0) 122 (181) 11 (28) 6 (14)

110 to 120 10 0.58 (14.8) 134 (200) 12 (30) 6 (15)

122 to 132 11 0.60 (15.3) 142 (212) 12 (31) 6 (15)

134 to 144 12 0.62 (15.8) 151 (225) 12 (32) 6 (16)

156 to 216 18 0.63 (16.1) 151 (225) 13 (32) 6 (16)

228 to 264 22 0.68 (17.3) 170 (253) 14 (35) 7 (17)

276 to 288 24 0.72 (18.3) 177 (264) 14 (36) 7 (18)

290 to 456 36 0.82 (20.9) 228 (339) 16 (42) 8 (21)

Page 30: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

30

LOO

SE T

UB

E /

CEN

TRA

L TU

BE

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

19B

LT

2.0

DR

Y 08

-17

LT 2.0 with Bend-Insensitive Fiber Dry loose tube cable

Dielectric Double Jacket (PDP) Dry (E2DNA2J)

Fiber Count # of Buffer Tubes

Diameterinches (mm)

Approximate Cable Weight

lb/kft (kg/km)

Bend Radius Load

inches (cm)

Bend Radius No Load

inches (cm)

4 to 72 6 0.42 (10.8) 54 (80) 8 (22) 4 (11)

74 to 84 7 0.45 (11.5) 61 (91) 9 (23) 5 (12)

86 to 96 8 0.47 (12.0) 66 (97) 9 (24) 5 (12)

98 to 108 9 0.50 (12.6) 73 (109) 10 (25) 5 (13)

110 to 120 10 0.52 (13.3) 81 (120) 10 (27) 5 (13)

122 to 132 11 0.55 (14.0) 89 (133) 11 (28) 5 (14)

134 to 144 12 0.57 (14.5) 97 (144) 11 (29) 6 (15)

156 to 216 18 0.57 (14.5) 97 (144) 11 (29) 6 (15)

218 to 264 22 0.63 (15.9) 110 (164) 13 (32) 6 (16)

266 to 288 24 0.65 (16.5) 119 (178) 13 (33) 7 (17)

Double Jacket Double Armored (SPSP) Dry (E2D2A2J)

Fiber Count # of Buffer Tubes

Diameterinches (mm)

Approximate Cable Weight

lb/kft (kg/km)

Bend Radius Load

inches (cm)

Bend Radius No Load

inches (cm)

4 to 72 6 0.63 (16.1) 178 (264) 13 (32) 6 (16)

74 to 84 7 0.66 (16.8) 196 (292) 13 (34) 7 (17)

86 to 96 8 0.67 (17.1) 203 (302) 13 (34) 7 (17)

98 to 108 9 0.70 (17.8) 219 (326) 14 (36) 7 (18)

110 to 120 10 0.73 (18.6) 239 (355) 15 (37) 7 (19)

122 to 132 11 0.75 (19.1) 254 (379) 15 (38) 8 (19)

134 to 144 12 0.77 (19.6) 270 (402) 15 (39) 8 (20)

134 to 216 18 0.77 (19.6) 263 (391) 15 (39) 8 (20)

218 to 264 22 0.83 (21.1) 291 (433) 17 (42) 8 (21)

266 to 288 24 0.85 (21.6) 304 (452) 17 (43) 9 (22)

Triple Jacket Double Armored (PSPSP) Dry (E2D2A3J)

Fiber Count # of Buffer Tubes

Diameterinches (mm)

Approximate Cable Weight

lb/kft (kg/km)

Bend Radius Load

inches (cm)

Bend Radius No Load

inches (cm)

4 to 72 6 0.68 (17.3) 202 (301) 14 (35) 7 (17)

74 to 84 7 0.70 (17.8) 210 (313) 14 (36) 7 (18)

86 to 96 8 0.71 (18.1) 221 (329) 14 (36) 7 (18)

98 to 108 9 0.74 (18.9) 238 (353) 15 (38) 7 (19)

110 to 120 10 0.77 (19.6) 255 (379) 15 (39) 8 (20)

122 to 132 11 0.79 (20.1) 267 (398) 16 (40) 8 (20)

134 to 144 12 0.81 (20.6) 277 (412) 16 (41) 8 (21)

146 to 216 18 0.82 (20.9) 278 (414) 16 (42) 8 (21)

218 to 264 22 0.87 (22.2) 306 (456) 17 (44) 9 (22)

266 to 288 24 0.91 (23.2) 316 (470) 18 (45) 9 (23)

Temperature RangeShipping and Storage: -40o F to +167o F (-40o C to +75o C)Installation: -22o F to +140o F (-30o C to +60o C)Operation: -40o F to +158o F (-40o C to +70o C)

Tensile RatingMaximum installation load: 600 lbf (2700 N)Maximum operation load: 180 lbf (800 N)

Page 31: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

31

LOO

SE TUB

E / CENTR

AL TU

BE

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

19B

LT

2.0

DR

Y 08

-17

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2017 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued August 2017.

Ordering GuideThe Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below.

F E2D 1A1J 12 B2 072 E3

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

E2D = LT 2.0 Dry

3 CONSTRUCTION

1JKT = Single Jacket

1A1J = Single Armor, Single Jacket

1A2J = Single Armor, Dual Jacket

2A2J = Double Armor, Dual Jacket

2A3J = Double Armor, Triple Jacket

NA2J = Non Armored, Dual Jacket

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE

Example: LT2.0 dry | single armor, single jacket (12 fibers/tube) with 72 bend-insensitive fibers (printed in feet)

FIBER INFORMATION

4 FIBER GROUPING

12 = 12f per tube

5 FIBER TYPE

SINGLE-MODE

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & B2 & G.652.D)

BX = BendBrightXS Single-Mode (ITU G.657.A2 & B2 & G.652.D)

6 FIBER COUNT

004 to 456 fibers

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm)

E3 = 0.35/0.35/0.25 dB/km 1310/1383/1550 nm

Other cable constructions and fiber performance grades available on request.

1

Page 32: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

32

LOO

SE T

UB

E /

CEN

TRA

L TU

BE

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS1

18 C

ENTR

ALI

NK

CD

A 1

0-16

CentraLink™ CD Central loose tube cable (gel or dry)

MANUFACTURED IN

Water Blocking Tape

Corrugated Steel Armor

Water Blocking Strength Members

MDPE Outer Jacket

Gel or Dry Buffer Tube

Ripcords

RUSLISTED

Economical armored protection for lower fiber counts, ideal for multipurpose aerial and underground use near the network edge. Overview Prysmian’s CentraLink™ CD cable packs all the benefits and performance packed into an efficient design with a single central loose tube with ezPrep® armor. A better fit and cost-effective alternative for low fiber count designs, this central loose tube cable provides easy cable entry and flexible routing for multipurpose installation of up to 12 fibers. Product Snapshot Applications Multi-purpose outdoor – aerial lashed, duct, direct buried Constructions Central loose tube, armored (single or double) Fiber Count 2 to 12 fibers Fiber Types Single-mode / bend-insensitive / multimode / hybrid Options Gel and dry Similar Central loose tube 300 / ExpressLT™/ Alternatives LT 2.0 / indoor-outdoor Performance ANSI/ICEA 640, IEC 60794-3-11, ANSI/ICEA S-110-717-2003, RUS 7 CFR 1755.903 (RUS Listed), Telcordia GR-20 Registered ISO 9001, ISO 14001, TL 9000, Supplier and OHSAS 18001

Features and Benefits Easy Cable Entry and Preparation - ezPrep® armor greatly improves mid-entry - The jacket can be easily separated from the armor - Ripcord speeds cable entry & outer jacket removal - Flexible buffer tube simplifies routing and splicing preparation - Single buffer tube eliminates removal of empty filler tubes

Flexible Routing and Termination - Single central buffer tube reduces size and bend diameter - Flexible strength members bend in any direction - Available with bend-insensitive single-mode fiber - Up to 20' of express buffer tube storage - Armored cable access, bonding and grounding are faster, easier and more safe Multi-Purpose Installation and Use - Suitable for aerial lashed, duct, and direct buried installation - Small diameter & light weight extend installation lengths - ezPrep® corrugated steel tape armor provides mechanical protection and rodent resistance

Page 33: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

33

LOO

SE TUB

E / CENTR

AL TU

BE

500A

DS1

18 C

ENTR

ALI

NK

CD

A 1

0-16

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2016 All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless authorized by Prysmian Group. Issued October 2016.

Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below.

Single Armor, Single Jacket

Part Number

Fiber Count

Tube Construction

Diameterinches (mm)

Cable Weightlb/kft (kg/km)

Bend Radius LOADinches (cm)

Bend Radius NO LOADinches (cm)

CL61A1J 2 to 12 Gel Tube 0.36 (9.1) 62 (93) 7 (18) 4 (9)

D6H1A1J 2 to 12 Dry 0.38 (9.7) 63 (94) 8 (20) 6 (15)

Temperature RangeShipping and Storage: -40o F to +167o F (-40o C to +75o C)Installation: -22o F to +140o F (-30o C to +60o C)Operation: -40o F to +158o F (-40o C to +70o C)

InstallationMaximum installation load: 600 lbf (2700 N)Maximum operation load: 180 lbf (800 N)

Nominal Design Parameters

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

CL6 = CentraLink™ CD Gel Tube

D6H = CentraLink™ CD Dry Tube (SMF with B1 or B2 fiber only)

3 CONSTRUCTION

1A1J = Single Armor, Single Jacket

4 FIBER GROUPING

12 = 12f per tube

F CL6 1A1J 12 HB 012 E3

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 C & D)

CE = Corning™ SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2 & G.652.D)

MULTIMODE Wavelength Bandwidth 1 GbE 10 GbE (nm) (MHz) Dist (m) Dist (m)

G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___

G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___

G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___

G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___

6 FIBER COUNT

001 to 012 fibers

1

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, CE, B1, or B2

E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, CE, B1, or B2

MULTIMODE Attenuation (dB/km) Wavelength (nm) Fiber Type

M2 = 3.5/1.0 850/1300 OM1 (62.5μm)

M3 = 3.0/1.0 850/1300 OM2+, OM3, OM4 (50μm)

Other cable constructions and fiber performance grades available on request.

Example: CentraLink CD, single armor, single jacket (12 fibers/tube) with 12 G.652.D LWP single-mode fIbers (printed in feet)

Page 34: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

34

LOO

SE T

UB

E /

CEN

TRA

L TU

BE

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS1

11A

CEN

TRA

LIN

K C

D D

A 1

1-16

CentraLink™ CD Double Armored Central loose tube cable

MANUFACTURED IN

RUSLISTED

Water Blocking Tape

Corrugated Steel Armor (inner layer)

Water Blocking Strength Members

Gel-Filled Buffer Tube Containing up to 12 Fibers

Inner Jacket

Corrugated Steel Armor (outer layer)

Outer Jacket

Ripcord (typical)

Features and Benefits Two Layers of Corrugated Steel Armor - Provides additional mechanical protection Dry Water-Blocking Technology - Permits rapid cable preparation and termination - Water-blocking materials are easily removed Flexible Buffer Tube - Superior kink resistance - Increased flexibility - Facilitates route management in closure - Eliminates need for closure transportation tubing Medium Density Polyethylene Jacket - Low friction installation - Excellent protection from environmental hazards Sheath Markings - Provide positive identification and length verification - Custom print available - Optional embedded stripe available for additional cable identification No Strength Members Embedded In The Jacket - Jacket and armor can be removed from the end in a single step - Mid-span access is safer and easier Easy Cable Entry and Preparation - ezPrep® armor greatly improves mid-entry - The jacket can be easily separated from the armor - Ripcord speeds cable entry & outer jacket removal

Performance - Meets or exceeds the requirements of Telcordia GR-20 and ICEA 640 and is tested in accordance with relevant EIA/TIA-455 series - RDUP listed (tested in accordance with PE-90) Registered Supplier - ISO 9001, ISO 14001, TL 9000, and OHSAS 18001

PERFORMANCE SPECIFICATIONS Bend RadiusDynamic 20 x Cable OD

Static 10 x Cable OD

Tensile Rating N lbf

Installation 2700 600

Residual 800 180

Crush Resistance N/cm lbf/in

Short/ Long Term 440/220 250/125

Temperature Ratings °C °F

Operation -40 to +70 -40 to +158

Installation -30 to +60 -22 to +140

Storage/Shipping -40 to +75 -40 to +167

Page 35: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

35

LOO

SE TUB

E / CENTR

AL TU

BE

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS1

11A

CEN

TRA

LIN

K C

D D

A 1

1-16

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2016 All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless authorized by Prysmian Group. Issued November 2016.

Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below.

Nominal Design Parameters

Fiber Count 2 to 12

Buffer Tube OD(mm) 3.0

(inches) 0.118

Cable OD(mm) 14.5

(inches) 0.57

Cable Weight(kg/km) 211(lb/kft) 142

Max. Length(m) 12,800(ft) 41,984

Example: 6 fiber CentraLinkTM CD Double Armored /Double Jacketed Cable with G.652.D LWP single-mode fiber and 0.35/0.35/0.25 attenuation.

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

C6H = CentraLink™ CD

3 CONSTRUCTION

2A2J = Double Armor, Double Jacket

4 FIBER GROUPING

12 = 12f per tube

Note: Please refer to the Fiber Code Addendum for additional fiber options, or contact us for help.

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 BB, CU, or B1

E3 = 0.35/0.35/0.25 1310/1383/1550 BB, CU, B1, or B2

MULTIMODE Attenuation (dB/km) Wavelength (nm) Fiber Type

M2 = 3.5/1.0 850/1300 OM1 (62.5μm)

M3 = 3.0/1.0 850/1300 OM2+, OM3, OM4 (50μm)

Other cable constructions and fiber performance grades available on request.

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

BB = BendBright™ Single-Mode (ITU G.657.A1 & G.652.D)

CU = Corning™ Ultra Single-Mode (ITU G.657.A1 & G.652.D)

MULTIMODE Wavelength Bandwidth 1 GbE 10 GbE (nm) (MHz) Dist (m) Dist (m)

G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___

G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___

G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___

G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___

6 FIBER COUNT

002 to 012 fibers

F C6H 2A2J 12 B1 006 E3

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE1

Page 36: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

36

500A

DS0

8 EZ

MIC

RO

UN

ITU

BE

01-1

8

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

ezMICROUNITUBE™ Central tube cable (gel)

MANUFACTURED IN

MDPE Outer Jacket

Armor (optional)

Dry Water Blocking Material

Strength Member(s)

Gel-Filled Buffer Tube

Optical Fibers

RUSLISTED

Simple central tube design with flexible access for up to 24 fibers Overview Prysmian’s ezMICROUNITUBE™ cables combine fiber bundles into a single central buffer tube. Users gain quick access to all fibers, with fiber bundles separated by color-coded binder threads. All ezMICROUNITUBE™ cables utilize longitudinal strength members for robust tensile strength and anti-buckling. Steel members are used with armored cable, dielectric is used with non-armored cable. The combination of adhesive armor, a flexible core tube, swellable water-blocking make ezMICROUNITUBE™ the easiest central tube cable to access and preparation.

Product Snapshot Applications Multi-purpose outdoor – aerial lashed, duct, direct buried Constructions Dielectric, armored Fiber Count 2 to 24 fibers in fiber bundles separated by color-coded binder threads Fiber Types Single-mode / bend-insensitive / NZDSF / multimode / hybrid Performance ANSI / ICEA 640, RUS 7 CFR 755 (RUS Listed), Telcordia GR-20 Registered ISO 9001, ISO 14001, TL 9000, Supplier and OHSAS 18001

Features and Benefits Easy Cable Entry and Preparation - Adhesive bond armor (armored version) greatly improves mid-entry - Ripcord speeds cable entry & outer jacket removal - Single core tube allows quick access to fibers - Flexible routing and termination - Single central buffer tube reduces size and bend diameter - Quick access to all fibers - Bend-insensitive single-mode fiber option Multi-Purpose Installation and Use - Suitable for aerial lashed, duct, and direct buried installation - Small diameter and light weight extend installation lengths - Corrugated steel tape armor provides mechanical protection and rodent resistance (armored version) Reliable Lifetime Performance - Proven water-blocking with swellable core tape and gel-filled buffer tube - Guaranteed standards-based performance

LOO

SE T

UB

E /

CEN

TRA

L TU

BE

Page 37: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

37

500A

DS0

8 EZ

MIC

RO

UN

ITU

BE

01-1

8

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

ORDERING GUIDEThe Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2017 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued April 2017.

Dielectric (UMH1JKT)

Fiber Count Diameterinches (mm)

Cable Weightlb/kft (kg/km)

Bend Radius | Loadinches (cm)

Bend Radius | No Loadinches (cm)

2 to 12 0.35 (8.8) 40 (60) 7 (18) 4 (9)

Armored (SP) (UMH1A1J)

Fiber Count Diameterinches (mm)

Cable Weightlb/kft (kg/km)

Bend Radius | Loadinches (cm)

Bend Radius | No Loadinches (cm)

2 to 24 0.41 (10.3) 77 (114) 8 (21) 6 (15)

Temperature RangeShipping and Storage: -40o F to +167o F (-40o C to +75o C)Installation: -22o F to +140o F (-30o C to +60o C)Operation: -40o F to +158o F (-40o C to +70o C)

InstallationMaximum installation load: 600 lbf (2670 N)Maximum operation load: 180 lbf (800 N)

Nominal Design Parameters

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

UMH = ezMICROUNITUBE

3 CONSTRUCTION

1JKT = Single Jacket (2 to 12f)

1A1J = Single Armor, Single Jacket (2 to 24f)

4 FIBER GROUPING

12 = 12f per unit or tube

24 = Two 12 fiber binder groups (14 to 24f)

F UMH 1A1J 12 HB 012 E3

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 C & D)

CE = Corning™ SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

MULTIMODE Wavelength Bandwidth 1 GbE 10 GbE (nm) (MHz) Dist (m) Dist (m)

G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___

G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___

G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___

G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___

6 FIBER COUNT

001 to 024 fibers

1

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

MULTIMODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, or CE M2 = 3.5/1.0 850/1300 OM1 (62.5μm)

E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, CE, B1 or B2 M3 = 3.0/1.0 850/1300 OM2+, OM3, OM4 (50μm)

Other cable constructions and fiber performance grades available on request.

Example: ezMICROUNITUBE, single armor single jacket with 12 single-mode fibers (printed in feet)

7 FIBER GRADE

LOO

SE TUB

E / CENTR

AL TU

BE

Page 38: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

38

500A

DS0

70 E

XPR

ESSL

T A

LL-D

IELE

CTR

IC A

RM

0R 0

1-17

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

ExpressLT™All-Dielectric Armor Cable

MANUFACTURED IN

RUSLISTED

Versatile all-dielectric cable for added robustness and small rodent retardent protection. OverviewPrysmian’s all-dielectric armor loose tube cable provides all the benefits of Prysmian’s loose tube cable along with enhanced mechanical protection. Multiple layers of fiberglass provide dielectric armoring, superior tensile strength, and small rodent retardant protection. Product Snapshot Applications Multi-purpose outdoor - aerial lashed, duct, direct buried Constructions Gel or dry buffer tubes Fiber Count 4 to 432 fibers in color-coded buffer tubes Fiber Types Single-mode / bend-insensitive / NZDSF / multimode / hybrid Options Steel central member / 22 or 24 AWG copper pair(s) / 16 AWG tonewire Other Versions Standard loose tube all-dielectric non-armor or metallic armor cable, gel or dry Performance ANSI/ICEA640, RUS 7 CFR 1755 (RUS Compliant), Telcordia GR-20 Registered ISO 9001, ISO 14001, TL 9000, Supplier and OHSAS 18001

Features and Benefits Enhanced Mechanical Protection - All-dielectric armor provides enhanced mechanical and from small rodent retardent protection - 1000 lbf tensile strength – 66% higher strength compared to standard loose tube cable - Multiple layers of fiberglass armoring between 2 polyethylene jackets maintain cable flexibility and easy cable handling, especially during cable terminations - Thicker outer jacket of high density polyethylene (HDPE) provide enhanced durability - Suitable for aerial lashed, duct, and direct buried applications Easy Cable Entry & Termination - Up to 20 foot mid-span buffer tube storage capability, allowing for easy mid-cable access - 2.5 mm flexible polypropylene buffer tubes provide flexibility for easy routing in closures up to 432 fibers - Available with G657.A2 fiber which has a bending loss 100 times lower than single-mode fiber Reliable Lifetime Performance - Tested for resistance against small rodents - Guaranteed standards-based performance

- Available with gel or dry buffer tubes - Proven water-blocking with swellable core elements and gel-filled buffer tubes

MDPE Inner Jacket

HDPE Outer Jacket

Ripcords

Fiberglass Yarn

Water Blocking Elements

Gel or Dry Buffer Tube Containing up to 12 Fibers

Central Strength Member

LOO

SE T

UB

E /

CEN

TRA

L TU

BE

Page 39: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

39

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom 50

0A D

S070

EX

PRES

SLT

ALL

-DIE

LECT

RIC

AR

M0R

01-

17

Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2017 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued January 2017.

All-Dielectric Armor Loose Tube (EDHDA2J) (ETHDA2J)

Fiber Count

Number of Buffer

Tubes

Buffer TubeDiameter

(mm)Buffer Tube

Material

NumberFibers

Per Tube

Mid-SpanTube Storage Length ft (m)

Diameterinches (mm)

Approximate Cable Weightlb/kft (kg/km)

Approximate Cable Weightlb/kft (kg/km)

Bend RadiusLoad

inches (cm)

Bend RadiusNo Load

inches (cm)

2 to 60 5 2.5 PP 12 20 (6.1) 0.50 (12.6) 77 (114) 80 (119) 10 (25) 5 (13)2 to 72 6 2.5 PP 12 20 (6.1) 0.53 (13.4) 86 (128) 90 (134) 11 (27) 5 (13)

74 to 96 8 2.5 PP 12 20 (6.1) 0.58 (14.7) 110 (163) 115 (171) 12 (29) 6 (15)98 to 120 10 2.5 PP 12 20 (6.1) 0.64 (16.3) 134 (200) 141 (210) 13 (32) 6 (17)122 to 144 12 2.5 PP 12 20 (6.1) 0.71 (18.1) 155 (230) 169 (252) 14 (36) 7 (18)146 to 216 18 2.5 PP 12 20 (6.1) 0.72 (18.4) 162 (241) 172 (256) 14 (37) 7 (18)218 to 288 24 2.5 PP 12 20 (6.1) 0.83 (21.0) 198 (264) 214 (318) 17 (42) 8 (21)290 to 432 18 3.0 PBT 24 16 (4.9) 0.81 (20.7) n/a 200 (298) 16 (41) 8 (21)

* PP = polypropylene 24 fiber tube contains two 12 fiber binder groups (blue & orange)

Nominal Design Parameters

Temperature RangeShipping and Storage: -40o F to +167o F (-40o C to +75o C)Installation: -22o F to +140o F (-30o C to +60o C)Operation: -40o F to +158o F (-40o C to +70o C)

InstallationMaximum installation load: 1000 lbf (4500 N)Maximum operation load: 300 lbf (1333 N)

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 C & D)

CE = Corning™ SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

TU = TeraLight Ultra Single-Mode (ITU G.655 & G.656)

LE = LEAF NZDSF (ITU G.655)

MULTIMODE Wavelength Bandwidth 1 GbE 10 GbE (nm) (MHz) Dist (m) Dist (m)

G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___

G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___

G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___

G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___

6 FIBER COUNT

004to 432 fibers

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

ETH = ExpressLT™ | Gel-filled tube

EDH = ExpressLT™ | Dry

3 CONSTRUCTION

DA2J = All-Dielectric Armor, Dual Jacket

4 FIBER GROUPING

12 = 12f per unit or tube

24 = 24f per tube with two 12 fiber groups

F EDH DA2J 12 HB 072 E3

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, or CE

E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, CE, B1, or B2

NA = 0.40/0.25 1310/1550 TeraLight Ultra SM

N1 = 0.25 1550 LEAF SM

MULTIMODE Attenuation (dB/km) Wavelength (nm) Fiber Type

M2 = 3.5/1.0 850/1300 OM1 (62.5μm)

M3 = 3.0/1.0 850/1300 OM2+, OM3, OM4 (50μm)

Example: ExpressLT™ dry loose tube | all-dielectric armor dual jacket, 72 fiber single-mode fibers (printed in feet)

1 LOO

SE TUB

E / CENTR

AL TU

BE

Page 40: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

40

RIB

BO

N

500A

DS1

00 F

USI

ON

LIN

K R

ICT

05-1

8

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-669-0808 | website: na.prysmiangroup.com/telecom

FusionLink™ RICT Ribbon central tube (gel) cable

MANUFACTURED IN

MANUFACTURED IN

Features and Benefits Compact Design - Efficient packaging of higher fiber counts - Lightweight and easy to handle during installation Easily Removable Ribbon Matrix - Allows for ease of stripping and fiber breakout - Improves mid-span strippability Precision Ribbon Geometry - Time and labor savings during fiber splicing Flexible Buffer Tube - Superior kink resistance - Increased flexibility - Facilitates route management in closures Dry Water-Blocking Technology - Permits rapid cable preparation and termination - Water-blocking materials are easily removed All-Dielectric Strength Elements - Jacket can be removed from the end in a single step - Mid-span access is safer and easier

Performance - Meets or exceeds the requirements of Telcordia GR-20 & ICEA 640 and is tested in accordance with relevant EIA/TIA-455 series FOTPs for fiber optic cables - RDUP listed (tested in accordance with PE-90)

Registered Supplier - ISO 9001, ISO 14001, TL 9000, and OHSAS 18001

PERFORMANCE SPECIFICATIONS Bend RadiusDynamic 20 x Cable OD

Static (Single Bend) 10 x Cable OD

Static (Cable Coil) 15 x Cable OD

Tensile Rating N lbf

Installation 2700 600

Residual 800 180

Crush Resistance N/cm lbf/inShort/ Long Term 220/110 125/63

Temperature Ratings °C °F

Operation -40 to +70 -40 to +158

Installation -30 to +60 -22 to +140

Storage/Shipping -40 to +75 -40 to +167

Water Blocking Tape

Ripcord

Gel-filled Buffer Tube

Strength Member

Ribbon Stack

MDPE Outer Jacket

RUSLISTED

Page 41: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

41

RIB

BO

N

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-669-0808 | website: na.prysmiangroup.com/telecom 50

0A D

S100

FU

SIO

NLI

NK

RIC

T 05

-18

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2018 All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless authorized by Prysmian Group. Issued May 2018.

Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below

Fiber Count 12-72 84-96 108-144 156-216 240-432* 456-576* 612-864*

Ribbon Count 1-6 7-8 9-12 13-18 10-18 19-24 17-24

Fibers/Ribbon 12 12 12 12 24 24 36

Buffer Tube OD(mm) 6.2 8.4 9.9 11.0 14.3 15.4 17.9

(inches) 0.24 0.33 0.39 0.43 0.56 0.61 0.70

Cable OD(mm) 12.9 15.1 16.6 17.7 21.0 20.0 22.7

(inches) 0.51 0.59 0.65 0.70 0.83 0.79 0.89

Cable Weight(kg/km) 130 173 207 247 370 374 424(lb/kft) 87 116 139 166 249 251 285

Max. Length(m) 11,821 10,470 9,162 9,162 5,445 5,445 3,267(ft) 38,773 34,342 30,051 30,051 17,864 17,864 10,718

Nominal Design Parameters

* Note: This design uses 24 fiber ribbons for counts of 240 to 576 and 36 fiber ribbons for 612 to 864 fibers.

Please refer to ribbon in loose tube designs for higher fiber counts using 12 fiber ribbons.

If on reel attuation testing is required for the 612-864 fiber designs, a reel with 60" drum must be specified on the order.

Example: 96 count FusionLinkTM cable with G.652.D LWP single-mode fiber and 0.40/0.40/0.30 attenuation. (printed in feet)

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

CE = Corning® SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

CU = Corning™ Ultra Single-Mode (ITU G.657.A1 & G.652.D)

6 FIBER COUNT

012 to 864 fibers

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, CE, B1, or CU

E3 = 0.35/0.35/0.25 1310/1383/1550 HB, CE, B1, or CUNote: Please refer to the Fiber Code Addendum for additional fiber options, or contact us for help.

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

RCG = FusionLink RICT

3 CONSTRUCTION

1JKT = Single Jacket

4 FIBER GROUPING

12 = 12f Ribbons

24 = 24f Ribbons

36 = 36f Ribbons

F RCG 1JKT 12 HB 096 E1

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE1

Page 42: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

42

RIB

BO

N

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS1

01 F

USI

ON

LIN

K A

05-

18

FusionLink™ ArmoredRibbon central tube (gel) cable

MANUFACTURED IN

MANUFACTURED IN

Features and Benefits Compact Design - Efficient packaging of higher fiber counts - Light weight and easy to handle during installation Easily Removable Ribbon Matrix - Allows for ease of stripping and fiber breakout - Improves mid-span strippability Precision Ribbon Geometry - Time and labor savings during fiber splicing Flexible Buffer Tube - Superior kink resistance - Increased flexibility - Facilitates route management in closures Dry Water-Blocking Technology - Permits rapid cable preparation and termination - Water-blocking materials are easily removed ezPrep® Corrugated Steel Armor - Provides additional mechanical protection - Special coating reduces time and effort to remove jacket

Performance - Meets or exceeds the requirements of Telcordia GR-20 & ICEA 640 and is tested in accordance with relevant EIA/TIA-455 series FOTPs for fiber optic cables - RDUP listed (tested in accordance with PE-90)

Registered Supplier - ISO 9001, ISO 14001, TL 9000, and OHSAS 180001

RUSLISTED

Corrugated Steel Armor

Steel Strength Member

Ribbon Stack

Water Blocking Tape

MDPE Outer Jacket

Ripcord

Gel-Filled Buffer Tube

PERFORMANCE SPECIFICATIONS Bend RadiusDynamic 20 x Cable OD

Static (Single Bend) 10 x Cable OD

Static (Cable Coil) 15 x Cable OD

Tensile Rating N lbf

Installation 2700 600

Residual 800 180

Crush Resistance N/cm lbf/inShort/ Long Term 220/110 125/63

Temperature Ratings °C °F

Operation -40 to +70 -40 to +158

Installation -30 to +60 -22 to +140

Storage/Shipping -40 to +75 -40 to +167

Page 43: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

43

RIB

BO

N

500A

DS1

01 F

USI

ON

LIN

K A

05-

18

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-669-0808 | website: na.prysmiangroup.com/telecom

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2018 All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless authorized by Prysmian Group. Issued May 2018.

Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below.

Fiber Count 12-72 84-96 108-216 240-432* 456-576* 612-864*

Ribbon Count 1-6 7-8 9-18 10-18 19-24 17-24

Fibers/Ribbon 12 12 12 24 24 36

Buffer Tube OD(mm) 6.2 8.4 11.0 14.3 15.4 17.9

(inches) 0.24 0.33 0.43 0.56 0.61 0.70

Cable OD(mm) 12.6 14.8 17.4 21.8 22.9 25.9

(inches) 0.50 0.58 0.69 0.86 0.90 1.02

Cable Weight(kg/km) 159 200 263 459 492 595(lb/kft) 107 134 176 308 331 400

Max. Length(m) 12,100 12,100 10,130 5,445 5,445 3,267(ft) 39,688 39,688 33,226 17,864 17,864 10,719

Nominal Design Parameters

Example: 96 count armored FusionLinkTM cable with G.652.D LWP single-mode fiber and 0.40/0.40/0.30 attenuation. (printed in feet)

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

CE = Corning® SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

CU = Corning™ Ultra Single-Mode (ITU G.657.A1 & G.652.D)

6 FIBER COUNT

012 to 864 fibers

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, CE, B1, or CU

E3 = 0.35/0.35/0.25 1310/1383/1550 HB, CE, B1, or CUNote: Please refer to the Fiber Code Addendum for additional fiber options, or contact us for help.

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

RCG = FusionLink™ Armored

3 CONSTRUCTION

1A1J = Single Armor, Single Jacket

4 FIBER GROUPING

12 = 12f Ribbons

24 = 24f Ribbons

36 = 36f Ribbons

F RCG 1A1J 12 HB 096 E1

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE1

* Note: This design uses 24 fiber ribbons for counts of 240 to 576 and 36 fiber ribbons for 612 to 864 fibers.

Please refer to ribbon in loose tube designs for higher fiber counts using 12 fiber ribbons.

If on reel attuation testing is required for the 612-864 fiber designs, a reel with 60" drum must be specified on the order.

Page 44: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

44

500A

DS1

02 D

RY

FUSI

ON

LIN

K 0

6-18

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-669-0808 | website: na.prysmiangroup.com/telecom

Dry FusionLink™ Ribbon central tube (dry) cable

Features and Benefits Compact Design - Efficient packaging of higher fiber counts - Lightweight and easy to handle during installation Easily Removable Ribbon Matrix - Allows for ease of stripping and fiber breakout - Improves mid-span strippability Precision Ribbon Geometry - Time and labor savings during fiber splicing Flexible Buffer Tube - Superior kink resistance - Increased flexibility - Facilitates route management in closures Dry Water-Blocking Technology - Buffer tube and core are completely dry -no gel - Permits rapid cable preparation and termination - Water-blocking materials are easily removed All-Dielectric Strength Elements - Jacket can be removed from the end in a single step - Mid-span access is safer and easier Available Uncoupled or Coupled Designs - Coupled design (RCD product) couples the ribbon stack with the cable which elimates the need for splice point coupling coils in aerial application - Un-coupled design (RCU product) requires the use of coupling coils at the splice points in aerial applications to prevent fiber retraction in closures

Performance - Meets or exceeds the requirements of Telcordia GR-20 & ICEA 640 and is tested in accordance with relevant EIA/TIA-455 series FOTPs for fiber optic cables - RDUP listed (tested in accordance with PE-90)

Registered Supplier - ISO 9001, ISO 14001, TL 9000, and OHSAS 18001

RUSLISTED

Dry Water-Blocked Buffer Tube

Strength Rod

Core Water Blocking Tape

MDPE Outer Jacket

Ribbon Stack

Ripcord

Water Blocking Tape (In Tube)

TH

E U S A /C A NADA

MANUFACTURED IN

PERFORMANCE SPECIFICATIONS Bend RadiusDynamic 20 x Cable OD

Static (Single Bend) 10 x Cable OD

Static (Cable Coil) 15 x Cable OD

Tensile Rating N lbf

Installation 2700 600

Residual 800 180

Crush Resistance N/cm lbf/inShort/ Long Term 220/110 125/63

Temperature Ratings °C °F

Operation -40 to +70 -40 to +158

Installation -30 to +60 -22 to +140

Storage/Shipping -40 to +75 -40 to +167

RIB

BO

N

Page 45: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

45

500A

DS1

02 D

RY

FUSI

ON

LIN

K 0

6-18

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-669-0808 | website: na.prysmiangroup.com/telecom

Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless authorized by Prysmian Group. Issued June 2018.

RCD Coupled Design Example (for 60 to 432, 612 to 864):

96 count Dry FusionLinkTM with G.652.D LWP single-mode fiber and 0.40/0.40/0.30 attenuation with coupling. (printed in feet)

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

CE = Corning® SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

CU = Corning™ Ultra Single-Mode (ITU G.657.A1 & G.652.D)

6 FIBER COUNT

12 to 864 fibers

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, CE, B1, or CU

* E3 = 0.35/0.35/0.25 1310/1383/1550 HB, CE, B1, or CU

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

RCD = Dry FusionLink™ Coupled Design (60 to 432, 612 to 864)

RCU = Dry FusionLink™ Uncoupled Design (12 to 48, 576): aerial coupling coils required

3 CONSTRUCTION

1JKT = Single Jacket

4 FIBER GROUPING

12 = 12f Ribbons

24 = 24f Ribbons

36 = 36f Ribbons

F RCD 1JKT 12 HB 096 E1

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE1

RCU Uncoupled Design Example (for 12 to 48, 576):

48 count Dry FusionLinkTM with G.652.D LWP single-mode fiber and 0.40/0.40/0.30 attenuation without coupling. (printed in feet)

F RCU 1JKT 12 HB 048 E1

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE1

1.

2.

* Note: This design uses 24 fiber ribbons for counts of 240 to 576 fibers and 36 fiber ribbons for 612 to 864 fibers. Please refer to ribbon in loose tube designs for higher fiber counts using 12 fiber ribbons. If on reel testing is required for the 612-864 fiber designs, a reel with 60" drum must be specified on the order.

PRODUCT FAMILY RCU1JKT RCD1JKT

Fiber Count 12-48 576* 60-72 84-96 108-144 156-216 240-288* 312-432* 612-864*

Ribbon Count 1-4 24 5-6 7-8 9-12 9-18 10-12 13-18 17-24

Fibers/Ribbon 12 24 12 12 12 12 24 24 36

Aerial Coupling Coils Required yes yes no no no no no no no

Buffer Tube OD(mm) 6.2 19.8 8.8 9.5 10.6 12.3 14.3 15.4 19.8

(inches) 0.24 0.78 0.35 0.37 0.42 0.48 0.56 0.61 0.78

Cable OD(mm) 12.7 24.6 15.3 16.0 17.1 18.8 20.3 20.0 24.6

(inches) 0.50 0.97 0.60 0.63 0.67 0.74 0.80 0.79 0.97

Cable Weight(kg/km) 114 345 155 162 176 202 247 256 345(lb/kft) 77 231 104 108 118 136 167 172 231

Max. Length(m) 11,706 5,445 11,706 11,706 10,248 8,479 5,445 5,445 3,267(ft) 38,405 17,864 38,405 38,405 33,622 27,818 17,864 17,864 10,718

Nominal Design Parameters

*612 to 864 fibers limited to E1 attenuation code.Note: Please refer to the Fiber Code Addendum for additional fiber options or contact us for help.

RIB

BO

N

Page 46: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

46

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

_DS1

03_D

RY_

FUSI

ON

LIN

K_A

RM

OR

ED_0

6-18

Dry FusionLink™ Armored Ribbon central tube (dry) cable

MANUFACTURED IN

Ribbon Stack

Water-Blocking Tape (In tube)

Water Blocking Tape

MDPE Outer Jacket

Ripcord

Dry Water-Blocked Buffer Tube

MANUFACTURED IN

Features and Benefits Compact Design - Efficient packaging of higher fiber counts - Lightweight and easy to handle during installation Easily Removable Ribbon Matrix - Allows for ease of stripping and fiber breakout - Improves mid-span strippability Precision Ribbon Geometry - Time and labor savings during fiber splicing Flexible Buffer Tube - Superior kink resistance - Increased flexibility - Facilitates route management in closures Dry Water-Blocking Technology - Buffer tube and core are completely dry —no gel - Permits rapid cable preparation and termination - Water-blocking materials are easily removed ezPrep® Corrugated Steel Armor - Provides additional mechanical protection - Special coating reduces time and effort to remove jacket Available Uncoupled or Coupled Designs - Coupled design (RCD product) couples the ribbon stack with the cable which elimates the need for splice point coupling coils in aerial application - Un-coupled design (RCU product) requires the use of coupling coils at the splice points in aerial applications to prevent fiber retraction in closures

Performance - Meets or exceeds the requirements of Telcordia GR-20 & ICEA 640 and is tested in accordance with relevant EIA/TIA-455 series FOTPs for fiber optic cables - Tested in accordance with relevant EIA/TIA-455 series FOTPs for fiber optic cables - Complies with RUS PE-90

Registered Supplier - ISO 9001, ISO 14001, TL 9000, and OHSAS 18001

RUSLISTED

PERFORMANCE SPECIFICATIONS Bend RadiusDynamic 20 x Cable OD

Static (Single Bend) 10 x Cable OD

Static (Cable Coil) 15 x Cable OD

Tensile Rating N lbf

Installation 2700 600

Residual 800 180

Crush Resistance N/cm lbf/inShort/ Long Term 220/110 125/63

Temperature Ratings °C °F

Operation -40 to +70 -40 to +158

Installation -30 to +60 -22 to +140

Storage/Shipping -40 to +75 -40 to +167

RIB

BO

N

Page 47: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

47

500A

_DS1

03_D

RY_

FUSI

ON

LIN

K_A

RM

OR

ED_0

6-18

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-669-0808 | website: na.prysmiangroup.com/telecom

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2018 All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless authorized by Prysmian Group. Issued June 2018.

PRODUCT FAMILY RCU1A1J RCD1A1J

Fiber Count 12-48 576* 60-72 84-96 108-144 156-216 240-288* 312-432* 612-864*

Ribbon Count 1-4 24 5-6 7-8 9-12 13-18 10-12 13-18 17-24

Fibers/Ribbon 12 24 12 12 12 12 24 24 36

Aerial Coupling Coils Required yes yes no no no no no no no

Buffer Tube OD(mm) 6.2 19.8 8.8 9.5 10.6 12.3 14.3 15.4 19.8

(inches) 0.24 0.78 0.35 0.37 0.42 0.48 0.56 0.61 0.78

Cable OD(mm) 12.5 27.8 16.3 17.0 18.1 19.8 21.4 22.9 27.8

(inches) 0.50 1.09 0.64 0.67 0.71 0.78 0.84 0.90 1.09

Cable Weight(kg/km) 152 533 224 233 258 285 364 391 533(lb/kft) 102 358 151 157 173 192 245 262 358

Max. Length(m) 11,187 4,960 11,187 10,095 8,880 7,580 5,445 5,445 3,267(ft) 36,693 16,275 36,693 33,111 29,126 24,862 17,864 17,864 10,718

Nominal Design Parameters

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

CE = Corning® SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

CU = Corning™ Ultra Single-Mode (ITU G.657.A1 & G.652.D)

6 FIBER COUNT

012 to 864 fibers

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, CE, B1, or CU

* E3 = 0.35/0.35/0.25 1310/1383/1550 HB, CE, B1, or CU

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

RCD = Dry FusionLink™ Coupled Design (60 to 432, 612 to 864)

RCU = Dry FusionLink™ Uncoupled Design (12 to 48, 576): aerial coupling coils required

3 CONSTRUCTION

1A1J = Single Armor, Single Jacket

4 FIBER GROUPING

12 = 12f Ribbons

24 = 24f Ribbons

36 = 36f Ribbons

Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below

RCD Coupled Design Example (for 60 to 432, 612 to 864):

96 count Dry FusionLinkTM Armored with G.652.D LWP single-mode fiber and 0.40/0.40/0.30 attenuation with coupling. (printed in feet)

F RCD 1A1J 12 HB 096 E1

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE1

RCU Uncoupled Design Example (for 12 to 48, 576):

48 count Dry FusionLinkTM Armored with G.652.D LWP single-mode fiber and 0.40/0.40/0.30 attenuation without coupling. (printed in feet)

F RCU 1A1J 12 HB 048 E1

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE1

1.

2.

* Note: This design uses 24 fiber ribbons for counts of 240 to 576 fibers and 36 fiber ribbons for 612 to 864 fibers. Please refer to ribbon in loose tube designs for higher fiber counts using 12 fiber ribbons. If on reel testing is required for the 612-864 fiber designs, a reel with 60" drum must be specified on the order.

* 612-864 fibers limited to E1 attenuation code.Note: Please refer to the Fiber Code Addendum for additional fiber options or contact us for help.

RIB

BO

N

Page 48: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

48

RIB

BO

N

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS1

04 M

ASS

LIN

K 6

-17

MassLink™ Multi-Tube Ribbon Cable

MANUFACTURED IN

Features and Benefits Compact Design - Efficient packaging of higher fiber counts - Lightweight and easy to handle during installation Easily Removable Ribbon Matrix - Allows for ease of stripping and fiber breakout Precision Ribbon Geometry - Time and labor savings during fiber splicing Dry Water-Blocking Technology - Permits rapid cable preparation and termination - Water-blocking materials are easily removed

Multiple Buffer Tubes Stranded In Reverse Oscillated Lay - Facilitates access of fibers when cable slack is not available - Smaller tubes have superior kink resistance and increased flexibility - Simplifies access, handling and management of fibers and ribbons - Eliminates need for closure transportation tubing and furcation kits Corrugated Steel Armor (Optional) - Provides additional mechanical protection (Prysmian recommends that only armored designs should be used in direct-buried applications) Copper Tracer Wires Available - Permits tone location of unarmored designs

Performance - Meets or exceeds the requirements of Telcordia GR-20 & ICEA 640 and is tested in accordance with relevant EIA/TIA-455 series - RDUP (RUS) listed (tested in accordance with PE-90, 7CFR 1755.900) Registered Supplier - ISO 9001, ISO 14001, TL 9000, and OHSAS 18001

PERFORMANCE SPECIFICATIONS Bend RadiusDynamic 20 x Cable OD

Static 10 x Cable OD

Tensile Rating N lbf

Installation 4500 1000

Residual 800 180

Crush Resistance N/cm lbf/in Short/ Long Term 220/110 125/63

Temperature Ratings °C °F

Operation -40 to +70 -40 to +158

Installation -30 to +60 -22 to +140

Storage/Shipping -40 to +75 -40 to +167

RUSLISTED

Outer Strength Members

Gel-Filled Buffer Tube With Fiber Ribbons

Water Blocking Tape

MDPE Inner Jacket (Double Jacket Designs Only)

MDPE Outer Jacket

Central Strength Member

Corrugated Steel Armor (Armored Designs Only)

Ripcord

Page 49: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

49

RIB

BO

N

500A

DS1

04 M

ASS

LIN

K 6

-17

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2017 All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless authorized by Prysmian Group. Issued June 2017.

Nominal Design Parameters

Jacket Design All-Dielectric All-DielectricSingle ArmorSingle Jacket

Single ArmorSingle Jacket

Single ArmorDouble Jacket

Fiber Count 288-432 444-864 288-432 444-864 288-432

#12f Ribbon/Tube 1-6 1-12 1-6 1-12 1-6

Tube Positions 6 6 6 6 6

Buffer Tube OD(mm) 6.2 7.9 6.2 7.9 6.2

(inches) 0.24 0.31 0.24 0.31 0.24

Cable OD(mm) 21.35 26.7 24.7 29.8 27.0

(inches) 0.84 1.05 0.97 1.17 1.06

Cable Weight(kg/km) 310 442 464 618 519(lb/kft) 208 297 311 415 348

Max. Length(m) 6,575 4,204 4,932 3,515 4,366(ft) 21,566 13,789 16,181 11,529 14,320

Example: 864 count armored MassLinkTM cable with G.652.D LWP single-mode fiber and 0.40/0.40/0.30 attenuation.

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 C & D)

CE = Corning™ SMF28e+ Single-Mode

LE = LEAF NZDSF (ITU G.655)

6 FIBER COUNT

288 to 864 fibers

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, or CE

E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, or CE

N1 = 0.25 1550 LEAF Single-Mode

Note: Please refer to the Fiber Code Addendum for additional fiber options, or contact us for help.

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

RLG = MassLink

3 CONSTRUCTION

1JKT = Single Jacket

1A1J = Single Armor, Single Jacket

1A2J = Single Armor, Double Jacket

4 FIBER GROUPING

12 = 12f Ribbons

F RLG 1A1J 12 HB 864 E1

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE1

Page 50: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

50

RIB

BO

N

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS1

05 M

ASS

LIN

K 1

728

02-1

8

MassLink™ 1728 Multi-Tube Ribbon Cable

MANUFACTURED IN

Ripcord

Gel-Filled Buffer Tube Containing Fiber Ribbons

Outer Strength Members

Water Blocking Tape

Steel Armor (where applicable)

Central Strength Member

Filler Rod

MDPE Outer Jacket

Features and Benefits Highest Fiber Count Available - Maximizes duct utilization in critical installations like bridge crossings - Ideal for connecting very large fiber distribution hubs - Lightweight and easier to handle than multiple smaller cables Easily Removable Ribbon Matrix - Both 12 and 24-fiber ribbons are easy to mass-strip - Individual fibers can be broken out quickly and cleanly Precision Ribbon Geometry - Time and labor savings during fiber splicing - Ribbons are easily split from 24-fiber units into separate 12-fiber units Available with ECCS ezPrep® (Steel) Armor - Rodent-Resistant - Facilitates tone location and increases resistance to mechanical stresses Dry Water-Blocking Technology - Permits rapid cable preparation and termination - Water-blocking materials are easily removed

Multiple Buffer Tubes Stranded in Reverse Oscillated Lay - Cable is uniformly flexible in all directions - Simplifies access, handling and management of fibers and ribbons - Termination management is easier with fewer ribbons in each tube

Performance - RDUP (RUS) listed (tested in accordance with PE-90, 7CFR 1755.900)

Registered Supplier - ISO 9001, ISO 14001, TL 9000, and OHSAS 18001

PERFORMANCE SPECIFICATIONS Bend RadiusDynamic 20 x Cable OD

Static 10 x Cable OD

Tensile Rating N lbf

Installation 4500 1000

Residual 800 180

Crush Resistance N/cm lbf/in Short/ Long Term 220/110 125/63

Temperature Ratings °C °F

Operation -40 to +70 -40 to +158

Installation -30 to +60 -22 to +140

Storage/Shipping -40 to +75 -40 to +167

RUSLISTED

Page 51: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

51

RIB

BO

N

500A

DS1

05 M

ASS

LIN

K 1

728

02-1

8

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2018 All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless authorized by Prysmian Group. Issued February 2018.

Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below.

Jacket Design All-Dielectric Single Armor / Single-Jacket

Fiber Count 1296-1728 1296-1728

Fibers/Tube 432 432

Tube Positions 4 4

Buffer Tube OD(mm) 12.1 12.1

(inches) 0.476 0.476

Cable OD(mm) 31.5 35.1

(inches) 1.24 1.38

Cable Weight(kg/km) 749 965(lb/kft) 503 647

Max. Length(m) 3,020 2,170(ft) 9,908 7,118

Nominal Design Parameters

Example: 1728 count armored MassLinkTM cable with G.652.D LWP single-mode fiber and 0.40/0.40/0.30 attenuation. (printed in feet)

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

CE = Corning™ SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

CU = Corning™ Ultra Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & B2 & G.652.D)

6 FIBER COUNT

1296 to 1728 fibers

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, CE, B1, CU or B2

Note: Please refer to the Fiber Code Addendum for additional fiber options, or contact us for help.

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

RLG = MassLink 1728

3 CONSTRUCTION

1JKT = Single Jacket

1A1J = Single Armor, Single Jacket

4 FIBER GROUPING

MX = Mix of 12f and 24f ribbons per unit or tube

F RLG 1A1J MX HB 1728 E1

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE1

Page 52: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

52

FLEX

TUB

E

500A

DS1

30 M

INI F

LEX

TUB

E 04

-15

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

Mini FlexTube® Duct dielectric optical flexible tube cable

Extremely flexible micro modules provide easy mid-span finger access to fibers without tools Overview Prysmian’s Mini FlexTube® dielectric cable with its small diameter is optimized for outdoor installations in duct by pulling or blowing. The cable can also be used in aerial lashed applications. With extremely flexible “kink-proof” micro modules, the cable allows faster terminations in closures and provides easy routing of modules. The micro module design allows easy finger access to fiber (no tools) in both end and mid-span applications.

Product Snapshot Applications Multi-purpose outdoor – duct and aerial lashed Construction All-dielectric Fiber Count 12 fibers bundles up to 288f Fiber Types Single-mode, bend-insensitive fiber Performance IEC 60794-3-11

PERFORMANCE SPECIFICATIONS Bend RadiusDynamic 20 x Cable OD

Static 10 x Cable OD

Crush Resistance N/cm lbf/inShort/Long Term 200 113

Impact Nm3 impacts, r=300mm 200

Temperature Ratings °C °FOperation -30 to +60 -22 to +140Installation -5 to +40 +23 to +104Storage/Shipping -40 to +70 -40 to +158

Features and Benefits Micro Module Unit Design - Very soft and flexible module material provides an extremely flexible, effectively “kink proof” unit - No tube memory, extreme flexibility, and small diameter allows for easy routing of units in closures. - The small micro units have very little gel, making them practically gel-free which makes cleaning easy - Finger strippable module, even in mid-span applications, with no tube removal tools required - Micro module is not affected by mid-span express unit storage,longer lengths can be stored in closure

Easy Cable Entry and Preparation

- Fast access to fibers; easy to remove module material without tools - The small 1.3mm unit has ¼ the volume of conventional 2.5 mm tubes - Store 3.5 times more units or length in the same space - Small micro modules allow for storage in smaller closures - Up to 50% time savings in mid-sheath closure installations - G.657.A2 bend insensitive fiber allows for smaller tube or fiber radius storage. Use smaller closures or splice trays

Optimized Jetting Performance in Duct Applications

- Compact, small diameter cable design reduces cable space up to 40% - Smaller cable diameter improves blowing performance

HDPE Outer Jacket

Micro-Module

Glass Reinforced Member(s)Water tightness

Page 53: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

53

FLEXTU

BE

500A

DS1

30 M

INI F

LEX

TUB

E 04

-15

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2015 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued April 2015.

Nominal Design Parameters

Fiber Count 24-48 72 144 288

Micro Module OD (mm) 1.3 1.3 1.3 1.3

Cable OD(mm) 8 10 11.5 14

(inches) 0.31 0.39 0.45 0.55

Cable Weight(kg/km) 50 70 90 140

(lb/kft) 34 47 60 94

Max. installation Tension(lbf) 225 360 495 607

(N) 1000 1,600 2,200 2,700

Example: 48 count Mini-FlexTube, single jacketed cable with bend-insensitive fiber

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & G.652.D)

BX = BendBrightXS Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

6 FIBER COUNT

024 to 288 fibers

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E3 = 0.35/0.35/0.25 1310/1383/1550 HB, B1, B2 or BX

Other cable constructions and fiber performance grades available on request.

Note: Please refer to the Fiber Code Addendum for additional fiber options, or contact us for help.

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = feet or M = meters

2 PRODUCT FAMILY

FXT = Mini-FlexTube®

3 CONSTRUCTION

1JKT = Single Jacket

4 FIBER GROUPING

12 = 12f per tube

F FXT 1JKT 12 B2 048 E3

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE1

Ordering GuideThe Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described in the example.

Page 54: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

54

DR

OP

500A

DS0

11 C

ENTR

AL

LT 3

00 1

0-16

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

MANUFACTURED IN

Central Loose Tube 300 Central loose tube cable (gel or dry)

Water Blocking Tape

Corrugated Steel Armor

Water Blocking Strength Members

MDPE Outer Jacket

Buffer Tube - up to 12 Fibers

Ripcords

RUSLISTED

Economical armored protection for lower fiber counts, ideal for multi-purpose aerial and underground use near the network edge Overview Prysmian’s Central Loose Tube 300 cable is an excellent cost effective 300 lb tensile rated design for low fiber counts and provides flexible routing including multi-purpose drop applications. Product Snapshot Applications Multi-purpose outdoor – aerial lashed, duct, direct buried Constructions Central loose tube, armored (single jacket) Fiber Count 1 to 12 fibers Fiber Types Bend-insensitive single-mode (standard), multimode Options Ripcords, gel or dry Similar Central loose tube / ExpressLT / LT 2.0 / Alternatives indoor-outdoor/ Flat Drop Performance ANSI/ICEA S-110-717, RUS 7 CFR 1755.903 (RUS Listed), Telcordia GR-20 Registered ISO 9001, ISO 14001, TL 9000, Supplier and OHSAS 18001

Features and Benefits Easy Cable Entry and Preparation - ezPrep® armor greatly improves mid-entry - The jacket can be easily separated from the armor - Optional ripcord speeds cable entry & outer jacket removal - Flexible gel or dry buffer tube simplifies routing and splicing preparation - Single buffer tube eliminates removal of empty filler tubes

Flexible Routing and Termination - Single central buffer tube reduces size and bend diameter - Flexible strength members bend in any direction - Standard bend-insensitive single-mode fiber Multi-purpose Installation and Use - Suitable for aerial lashed, duct, and direct buried installation - Small diameter & light weight extend installation lengths - ezPrep® corrugated steel tape armor provides mechanical protection & rodent resistance Reliable Lifetime Performance - Guaranteed standards-based performance

Page 55: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

55

DR

OP

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

11 C

ENTR

AL

LT 3

00 1

0-16

ORDERING GUIDEThe Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2016 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued October 2016.

Temperature RangeShipping and Storage: -40o F to +167o F (-40o C to +75o C)Installation: -22o F to +140o F (-30o C to +60o C)Operation: -40o F to +158o F (-40o C to +70o C)

InstallationMaximum installation load: 300 lbf (1335 N)Maximum operation load: 90 lbf (400 N)

Fiber Count

Tube Construction

Diameterinches (mm)

Cable Weightlb/kft (kg/km)

Bend Radius LOADinches (cm)

Bend Radius NO LOADinches (cm)

1 to 12 Gel Tube 0.38 (9.7) 57 (85) 8 (20) 6 (15)

1 to 12 Dry Tube 0.38 (9.7) 56 (83) 8 (20) 6 (15)

Nominal Design Parameters

Example: Central loose tube 300, sIngle armor single jacket (12 fibers/tube) with 12 bend-insensitive single-mode fibers in a gel tube, no ripcord.

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

C3H = Central Loose Tube 300 Without Ripcord

C3R = Central Loose Tube 300 With Ripcord

D3H = Central Loose Tube 300 Dry Without Ripcord

D3R = Central Loose Tube 300 Dry With Ripcord

3 CONSTRUCTION

1A1J = Single Armor, Single Jacket

4 FIBER GROUPING

12 = 12f per tube

F C3H 1A1J 12 B1 012 E3

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE1

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & B2 & G.652.D)

MULTIMODE Wavelength Bandwidth 1 GbE 10 GbE (nm) (MHz) Dist (m) Dist (m)

G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___

G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___

G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___

G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___

6 FIBER COUNT

001 to 012 fibers

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 B1 or B2

E3 = 0.35/0.35/0.25 1310/1383/1550 B1 or B2

MULTIMODE Attenuation (dB/km) Wavelength (nm)

M2 = 3.5/1.0 850/1300

M3 = 3.0/1.0 850/1300

Other cable constructions and fiber performance grades available on request.

Page 56: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

56

DR

OP

500A

DS1

12A

RES

ILIN

K A

DF

01-1

8

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

MANUFACTURED IN

ResiLink™ ADF | Flat Drop DielectricAll-dielectric flat drop cable

HDPE Outer Jacket

Strength Member

Gel-Filled Buffer Tube (up to 12 Fibers)

Water-Blocking Material

MANUFACTURED IN

Dimensions and Weights

Buffer Tube OD 3.0 mm (0.12 in)

Cable Thickness 4.7 mm (0.19 in)

Cable Width 8.3 mm (0.33 in)

Cable Weight 32.6 kg/km (21.9 lbs/kft)

Max Cable Length 25,000 m (82,000 ft)

Features and Benefits Easy Access Design - The jacket can be easily opened with a knife - The buffer tube is easily separated from the jacket and strength members All-Dielectric Messengers - No bonding or grounding required - Flexible and kink resistant Dry Water-Blocking Technology - Permits rapid cable preparation and termination - Water-blocking materials are easily removed Versatile Design - Small cross-section and high strength provide good aerial performance - Can be pushed or pulled through duct - Highly crush-resistant Dual Strength Member Design - More flexible than a single, all-dielectric rod of the same strength - Easier to handle and coil than comparable all-dielectric figure-8 designs - A great alternative where steel strength members are not permissible High Density Polyethylene Jacket - Low friction installation - Excellent protection from environmental hazards

Sheath Markings - Provides positive identification and length verification Performance - RDUP listed (tested in accordance with PE-90) - Complies with Telcordia GR-20, ICEA 717 and RUS 1755.903 Registered Supplier - ISO 9001, ISO 14001, TL 9000, and OHSAS 18001

PERFORMANCE SPECIFICATIONS Bend Radius mm inchesDynamic 150 5.9

Static 100 3.9

Tensile Rating N lbfInstallation Load 1336 300

Temperature Ratings °C °FOperation -40 to +70 -40 to +158Installation -30 to +60 -22 to +140

Storage/Shipping -40 to +75 -40 to +167

Maximum Span Distance

Installation SAG

NESC Heavyft (m)

NESC Medium ft (m)

NESC Lightft (m)

1% 150 (45) 260 (79) 330 (100)1.5% 160 (49) 280 (85) 370 (112)3% 185 (56) 330 (100) 450 (137)

Page 57: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

57

DR

OP

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS1

12A

RES

ILIN

K A

DF

01-1

8

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2018 All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless authorized by Prysmian Group. Issued January 2018.

Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below

Package Options

Package Dimensions H x W x Dinches (cm)

Capacityft (m)

Ship Weightlbs (kg)

18” Plywood Reel 18 x 15 x 8 (46 x 38 x 20) 2600 (800) 74 (33.6)

29.5” Plywood Reel 29.5 x 18 x 12 (76 x 46 x 30) 8000 (2450) 249 (113)

24” Plywood Reel 23.5 x 9.25 x 12 (60 x 25 x 30) 2600 (800) 91 (41)

30” Plywood Reel 29 x 12 x 12 (74 x 30 x 30) 4300 (1300) 150 (68)

*Note: This reel is not rated for long term outdoor storage. This cable is also available in longer lengths on standard OSP reels

Example: ResiLink flat dielectric, flat drop (12 fibers/tube) with 2 single-mode fibers (printed in feet)

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

DFD = ResiLink All-Dielectric Flat Drop Cable

3 CONSTRUCTION

1JKT = Non-Armored

4 FIBER GROUPING

12 = 12f per tube

F DFD 1JKT 12 B1 002 E3

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

CU = Corning™ Ultra Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

6 FIBER COUNT

001 to 012 fibers

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E3 = 0.35/0.35/0.25 1310/1383/1550 B1, CU or B2

Other cable constructions and fiber performance grades available on request.

Mounting Hardware - Clamp

ManufacturerCatalog Number

ClampDescription

Belden 23-88881 2 Pair Stainless Steel Drop Wire Clamp

Hardware available at:Power & Telephone Supply Company: 800-238-7514

1

ResiLink™ ADF | Flat Drop DielectricAll-dielectric flat drop cable

Page 58: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

58

DR

OP

500A

DS1

13A

RES

ILIN

K T

F 01

-18

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

MANUFACTURED IN

MANUFACTURED IN

ResiLink™ TF | Flat Drop ToneableToneable flat drop cable

24 AWG Tracer Wire

Features and Benefits Easy Access Design - The jacket can be easily opened with a knife - The buffer tube is easily separated from the jacket and strength members

External Tracer Wire in a Webbed Configuration - Simplifies location of the cable after installation - Can be grounded or accessed without opening the rest of the cable - Easily separated from the rest of the cable without compromising the jacket All-Dielectric Messengers - No bonding or grounding required - Flexible and kink resistant Dry Water-Blocking Technology - Permits rapid cable preparation and termination - Water-blocking materials are easily removed Versatile Design - Small cross-section and high strength provide good aerial performance - Can be pushed or pulled through duct - Highly crush-resistant Dual Strength Member Design - Provides more flexibility than a single rod of the same strength - Easier to handle and coil than comparable figure-8 designs - A great alternative where steel strength members are not permissible

Medium Density Polyethylene Jacket - Low friction installation - Excellent protection from environmental hazards Sheath Markings - Provides positive identification and length verification Performance - RDUP listed (tested in accordance with PE-90) - Complies with Telcordia GR-20, ICEA 717 and RUS 1755.903 Registered Supplier - ISO 9001, ISO 14001, TL 9000, and OHSAS 18001

Dimensions and Weights

Buffer Tube OD 3.0 mm (0.12 in)

Cable Thickness 4.7 mm (0.19 in)

Cable Width 10.5 mm (0.41 in)

Cable Weight 36 kg/km (24 lbs/kft)

Max Cable Length 25,000 m (82,000 ft)

PERFORMANCE SPECIFICATIONS Bend Radius mm inchesDynamic 150 5.9

Static 100 3.9

Tensile Rating N lbfInstallation Load 1336 300

Temperature Ratings °C °FOperation -40 to +70 -40 to +158Installation -30 to +60 -22 to +140

Storage/Shipping -40 to +75 -40 to +167

Maximum Span Distance

Installation SAG

NESC Heavyft (m)

NESC Medium ft (m)

NESC Lightft (m)

1% 150 (45) 260 (79) 330 (100)1.5% 160 (49) 280 (85) 370 (112)3% 185 (56) 330 (100) 450 (137)

HDPE Outer Jacket

Strength Member

Gel-Filled Buffer Tube (up to 12 Fibers)

Water-Blocking Material

Page 59: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

59

DR

OP

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS1

13A

RES

ILIN

K T

F 01

-18

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2018 All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless authorized by Prysmian Group. Issued January 2018.

Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below.

Package Options

PackageDimensions H x W x D

inches (cm)Capacity

ft (m)Ship Weight

lbs (kg)

18” Plywood Reel 18 x 15 x 8 (46 x 38 x 20) 1800 (550) 55 (24.9)

29.5” Plywood Reel 29.5 x 18 x 12 (76 x 46 x 30) 8000 (2450) 243 (110.2)

24” Plywood Reel 23.5 x 9.25 x 12 (60 x 25 x 30) 1800 (550) 73 (33.1)

30” Plywood Reel 29 x 12 x 12 (74 x 30 x 30) 3000 (925) 122 (553)

*Note: This reel is not rated for long term outdoor storage. This cable is also available in longer lengths on standard OSP reels.

Mounting Hardware - Clamp

ManufacturerCatalog Number

ClampDescription

Belden 23-88881 2 Pair Stainless Steel Drop Wire Clamp

Example: ResiLink flat toneable, flat drop (12 fibers/tube) with 2 single-mode fibers (printed in feet)

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

DFD = ResiLink Flat Drop Cable

3 CONSTRUCTION

NATJ = Non- Armor, Toneable Jacket

4 FIBER GROUPING

12 = 12f per tube

F DFD NATJ 12 B1 002 E3

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE

Hardware available at:Power & Telephone Supply Company: 800-238-7514

1

ResiLink™ TF | Flat Drop ToneableToneable flat drop cable

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

CU = Corning™ Ultra Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

6 FIBER COUNT

001 to 012 fibers

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E3 = 0.35/0.35/0.25 1310/1383/1550 B1, CU or B2

Other cable constructions and fiber performance grades available on request.

Page 60: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

60

DR

OP

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom 50

0A D

S086

TO

NEA

BLE

RO

UN

D D

RO

P 10

-16

Toneable Round Drop

MANUFACTURED IN

Subunit can be easily seperated for routing into dwelling. Tone wire allows for easy cable location in underground applications.

Overview Prysmian’s versatile outdoor rated drop for duct applications that contains a 2 fiber indoor riser rated MDU cable and a 22 AWG tone wire. Features and Benefits Versatile Design - Outdoor rated cable contains 22 AWG wire for toning - Internal white 4.9mm round sub-unit (Riser/FT4 flame rated) allows routing directly into customer premise - MDU unit contains two EZstrip™ tight buffered units for easy connectorization or splicing - MDU sub-unit is compatible with stapling (T25 Round Crown Staples)

Easy Access Design - Jacket ridge shows location of strength element for safe cable entry - Subunit is easily separated from the cable - EZstrip tight buffered fibers allow for fast fiber stripping - Ripcords for easy removal of long sub-unit lengths Reliability - Rugged 4.9mm sub-unit - ITU G657.B3 Bend-Insensitive fiber provides extreme bending performance (down to 5mm radius) - 200 kpsi fibers are proof tested at twice the load of standard fibers for enhanced lifetime reliability - Tone wire allows easy location to avoid damage when installing other cables

Armid Strength Yarns

Linear Low Density PE Jacket

Poly Ripcords

2 Tight Buffer Fibers

GRP

22 AWG Copper Wire4.9mm White PVC Riser Subunit

MANUFACTURED IN

PERFORMANCE SPECIFICATIONS (Below Test per GR20 & ICEA 717 Requirements) Bend RadiusDynamic 20 x Cable OD

Static 10 x Cable OD

Tensile Rating N lbfInstallation 450 100

Residual 135 30

Crush Resistance N/cm lbf/in

Short/Long Term 440/130 250/75

Temperature Ratings °C °FOperation -40 to +70 -40 to +158Installation -20 to +60 -4 to +140

Storage/Shipping -40 to +75 -40 to +167

Cable Twist 2m twist, 10 cycles per ICEA 717

Cyclic Flex 25 cycles per ICEA 717

Low High Bend -30C & +60C per ICEA 717

Staple Test (20 T25) < 0.10 dB at 1550nm

Water Penetration 3m length

Dimensions and Weights

Buffer Tube OD 4.9 mm (0.19 in)

Cable OD 7.6 mm (0.3 in)

Cable Weight 49 kg/km (33 lbs/kft)

Registered Supplier - ISO 9001, ISO 14001, TL 9000, and OHSAS 18001

Page 61: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

61

DR

OP

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom 50

0A D

S086

TO

NEA

BLE

RO

UN

D D

RO

P 10

-16

Ordering Guide

The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2015 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued October 2016.

EXAMPLE: 2 fiber round toneable drop with ITUG657.B3 bend insensitive fiber

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

DTR = Round Toneable Drop

3 CONSTRUCTION

1JKT = Non-Armored

4 FIBER GROUPING

2 = 2f per unit

F DTR 1JKT 02 B3 002 E3

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

B3 = Bend-Insensitive Single-Mode (ITU G.657.B3 Bend-Insensitive Fiber)

BE = BendBright Elite Bend-Insensitive Single Mode (ITU G.657.B3 & G.652.D)

6 FIBER COUNT

001 to 002 fibers

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E3 = 0.35/0.35/0.25 1310/1383/1550 B3 or BE

Other cable constructions and fiber performance grades available on request.

1

Page 62: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

62

DR

OP

500A

DS0

82 E

ZD

RO

P FI

GU

RE8

10-

16

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

Versatile “Figure 8” fiber drop cable with integrated messenger for self-support and/or underground location.

Overview Prysmian’s ezDROP® Figure 8 cable provides easy FTTx (Fiber-To-The-x) installation and termination using existing hardware and methods for drops to homes and businesses. The integrated steel messenger provides self-support strength up to 400 feet (125 meters) and acts as a toning wire for underground location capability. It is attached by a web for easy tear-away separation from the cable. Portable spools simplify widespread deployment. Prysmian’s exclusive Bend-Insensitive fiber provides craft-friendly bend tolerance.

Product Snapshot Applications Multi-purpose FTTx - aerial self-support, direct buried, duct Constructions Integrated messenger, non-armored Fiber Count 2 to 6 fibers Fiber Types Bend-Insensitive single-mode fiber standard Options Packaging: spool / bulk Performance ANSI/ICEA 717, IEC, RUS 7 CFR 1755

(RUS LISTED), Telcordia GR-20 (drop cable requirements)

Registered ISO 9001, ISO 14001, TL 9000, Supplier and OHSAS 18001

ezDrop™ Figure 8Integrated Messenger Drop Cable

Features and Benefits Easy Cable Entry and Preparation - 3/32" stranded galvanized steel messenger for flexibility - Compatible with existing figure 8 installation hardware and methods - Tear-away messenger simplifies grounding - Ripcord speeds cable entry and jacket removal - Toneable messenger enables underground locating Flexible Routing and Termination - Flexible buffer tube simplifies routing and splicing - Standard G657.A1 bend-sensitive single-mode fiber Multi-Purpose Installation and Use - Suitable for aerial lashed, duct, and direct buried installation - Portable spool packaging Reliable Lifetime Performance - Guaranteed standards-based performance - Gel-filled buffer tube

MANUFACTURED IN

Fiber Sub-Unit

Messenger Jacket

Aramid Strength Yarns

Gel-Filled Buffer Tube Containing up to 12 Fibers

Jacket Web

Stranded Galvanized Steel Messenger

RUSLISTED

Page 63: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

63

DR

OP

500A

DS0

82 E

ZD

RO

P FI

GU

RE8

10-

16

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

ezDrop™ Figure 8Integrated Messenger Drop Cable

Dielectric (DF81JKT)

Fiber CountBuffer Tube Inches (mm)

Diameter Inches (mm)

Heightinches (mm)

Approximate Cable Weight

lb/kft (kg/km)

Bend RadiusLoad

inches (cm)

Bend Radius No Load

inches (cm)

1 - 6 0.075 (1.9) 0.16 (4.1) 0.34 (8.8) 33 (49) 6 (15) 6 (15)

Aerial Loading Specifications

@ 1% Installation Sag Maximum Span feet (m)

Maximum Installation Tension lbs (N)

NESC Heavy 150 (45) 62 (275)

NESC Medium 265 (80) 109 (485)

NESC Light 410 (125) 169 (750)

Package Options

Description Capacityft (m)

Dimensions H x W x DInches (cm)

Shipping Weightlbs (kg)

R-18 Ply 2100 (640) 18 x 15 x 8 (46 x 38 x 20) 75 (34)

R-30 Ply 9500 (2895) 30 x 18 x 20 (76 x 46 x 51) 370 (190)

ATTACHMENT HARDWARE:Wirevise and Wirelink Clamps -available from MacLean Power Systems (Formerly Reliable Power Products) Catalog/Part# 5056

Temperature Range

Installation

Shipping and Storage: -40o F to +167o F (-40o C to +75o C)Installation: -22o F to +140o F (-30o C to +60o C)Operation: -40o F to +158o F (-40o C to +70o C)

Maximum short term pulling load: 300 lbf (1335 N)

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2016 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued October 2016.

Ordering Guide

EXAMPLE: ezDROP | Figure 8, Single Jacket (6 Fibers/Bundle) with 2 Bend-Insensitive Single-Mode Fibers (printed in feet)

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

DF8 = ezDROP Figure 8

3 CONSTRUCTION

1JKT = Single Jacket

4 FIBER GROUPING

6 = 6f per unit or tube

F DF8 1JKT 06 B1 002 E1

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE

The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & B2 & G.652.D)

6 FIBER COUNT

002 to 006 fibers

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 B1 or B2

E3 = 0.35/0.35/0.25 1310/1383/1550 B1 or B2

Other cable constructions and fiber performance grades available on request.

1

Page 64: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

64

DR

OP

500A

DS1

14 R

ESIL

INK

USD

DIE

LECT

RIC

OR

TO

NEA

BLE

10-

16

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

MANUFACTURED IN

ResiLink™ USDUniversal service drop cable (dielectric and toneable)

Features and Benefits Dual Purpose Design - The complete cable is used as an outdoor drop - The inner sub-unit is a stand-alone 3 mm simplex cable with 900 micron tight buffer fiber All-Dielectric or Toneable - All-dielectric version eliminates the need for bonding or grounding - Optional 24 AWG tone wire is easily separated from the cable Dry Water-Blocking Technology - Permits rapid cable preparation and termination - Water-blocking materials are easily removed Versatile Design - Robust outer cable stands up to tough conditions in the outside plant - Outer cable is easily removed for segments that go indoors - Simplex sub-unit is compact and UL listed for indoor use. 900 micron tight buffer for easy connectorization - Can be used aerially or in duct Dual Strength Member Design - Fits into a standard wedge clamp (P-clamp) - Fully self-supporting - A great alternative where steel strength members are not permissible Medium Density Polyethylene Outer Jacket - Low friction installation - Excellent protection from environmental hazards

Sheath Markings - Provides positive identification and length verification - Custom print available Performance - Complete cable meets GR-20 - Sub-unit is rated OFNR-LS and meets GR-409 (indoor cable) **NOTE: that outer cable should be removed prior to installing indoors **

Registered Supplier - ISO 9001, ISO 14001, TL 9000, and OHSAS 18001

PERFORMANCE SPECIFICATIONS Bend Radius mm inchesDynamic 150 5.9

Static 100 3.9

Tensile Rating N lbfInstallation Load 1336 300

Span Rating* m ft

NESC Light Load District 100 330

NESC Medium Load District 76 250

NESC Heavy Load District 46 150

Temperature Ratings °C °F

Operation -40 to +70 -40 to +158

Installation -30 to +60 -22 to +140

Storage/Shipping -40 to +75 -40 to +167

*Minimum 1% installed sag

Outer Jacket

Strength Member

2.9mm Simplex Sub-Unit w/ 900 micron TB

Optional 24 AWG Tracer Wire

Page 65: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

65

DR

OP

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS1

14 R

ESIL

INK

USD

DIE

LECT

RIC

OR

TO

NEA

BLE

10-

16

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2016 All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless authorized by Prysmian Group. Issued October 2016.

Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below.

Dimensions and Weights

Dielectric ToneableSub-Unit OD 2.9 mm (0.11 in) 2.9 mm (0.11 in)

Cable Thickness 4.4 mm (0.17 in) 4.4 mm (0.17 in)

Cable Width 8.1 mm (0.32 in) 10.3 mm (0.41 in)

Cable Weight 32 kg/km (22 lbs/kft) 36 kg/km (24 lbs/kft)

Max Cable Length 12,500 m (41,000 ft) 12,500 m (41,000 ft)

Reel Size (Max Length) 2,000 m (6,560 ft)

Compact Reels*

30" x 12" Reel

Reel Weight 17 kg (38 lbs)

Reel Capacity 1,300 m (4,300 ft)

24" x 12" Rreel

Reel Weight 10 kg ( 23 lbs)

Reel Capacity 800 m (2,600 ft)

*Note: This reel is not rated for long-term outdoor storage. This cable is also available in longer lengths on standard OSP reels.

Example: 1 fiber ResiLinkTM all-dielectric USD cable with G.657.A2 & G.652.D bend-insensitive s ingle-mode fiber with 0.40/0.40/0.30 attenuation.

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

6 FIBER COUNT

001 fiber

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 B2

Note: Please refer to the Fiber Code Addendum for additional fiber options, or contact us for help.

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

D3D = ResiLink™ USD

3 CONSTRUCTION

NATJ = Non-Armor, Toneable Jacket

1JKT = Single Jacket

4 FIBER GROUPING

01 = 1f per unit or tube

F D3D 1JKT 01 B2 001 E1

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE1

Page 66: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

66

500A

DS0

8 EZ

MIC

RO

UN

ITU

BE

01-1

8

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

ezMICROUNITUBE™ Central tube cable (gel)

MANUFACTURED IN

MDPE Outer Jacket

Armor (optional)

Dry Water Blocking Material

Strength Member(s)

Gel-Filled Buffer Tube

Optical Fibers

RUSLISTED

Simple central tube design with flexible access for up to 24 fibers Overview Prysmian’s ezMICROUNITUBE™ cables combine fiber bundles into a single central buffer tube. Users gain quick access to all fibers, with fiber bundles separated by color-coded binder threads. All ezMICROUNITUBE™ cables utilize longitudinal strength members for robust tensile strength and anti-buckling. Steel members are used with armored cable, dielectric is used with non-armored cable. The combination of adhesive armor, a flexible core tube, swellable water-blocking make ezMICROUNITUBE™ the easiest central tube cable to access and preparation.

Product Snapshot Applications Multi-purpose outdoor – aerial lashed, duct, direct buried Constructions Dielectric, armored Fiber Count 2 to 24 fibers in fiber bundles separated by color-coded binder threads Fiber Types Single-mode / bend-insensitive / NZDSF / multimode / hybrid Performance ANSI / ICEA 640, RUS 7 CFR 755 (RUS Listed), Telcordia GR-20 Registered ISO 9001, ISO 14001, TL 9000, Supplier and OHSAS 18001

Features and Benefits Easy Cable Entry and Preparation - Adhesive bond armor (armored version) greatly improves mid-entry - Ripcord speeds cable entry & outer jacket removal - Single core tube allows quick access to fibers - Flexible routing and termination - Single central buffer tube reduces size and bend diameter - Quick access to all fibers - Bend-insensitive single-mode fiber option Multi-Purpose Installation and Use - Suitable for aerial lashed, duct, and direct buried installation - Small diameter and light weight extend installation lengths - Corrugated steel tape armor provides mechanical protection and rodent resistance (armored version) Reliable Lifetime Performance - Proven water-blocking with swellable core tape and gel-filled buffer tube - Guaranteed standards-based performance

DR

OP

Page 67: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

67

500A

DS0

8 EZ

MIC

RO

UN

ITU

BE

01-1

8

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

ORDERING GUIDEThe Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2017 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued April 2017.

Dielectric (UMH1JKT)

Fiber Count Diameterinches (mm)

Cable Weightlb/kft (kg/km)

Bend Radius | Loadinches (cm)

Bend Radius | No Loadinches (cm)

2 to 12 0.35 (8.8) 40 (60) 7 (18) 4 (9)

Armored (SP) (UMH1A1J)

Fiber Count Diameterinches (mm)

Cable Weightlb/kft (kg/km)

Bend Radius | Loadinches (cm)

Bend Radius | No Loadinches (cm)

2 to 24 0.41 (10.3) 77 (114) 8 (21) 6 (15)

Temperature RangeShipping and Storage: -40o F to +167o F (-40o C to +75o C)Installation: -22o F to +140o F (-30o C to +60o C)Operation: -40o F to +158o F (-40o C to +70o C)

InstallationMaximum installation load: 600 lbf (2670 N)Maximum operation load: 180 lbf (800 N)

Nominal Design Parameters

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

UMH = ezMICROUNITUBE

3 CONSTRUCTION

1JKT = Single Jacket (2 to 12f)

1A1J = Single Armor, Single Jacket (2 to 24f)

4 FIBER GROUPING

12 = 12f per unit or tube

24 = Two 12 fiber binder groups (14 to 24f)

F UMH 1A1J 12 HB 012 E3

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 C & D)

CE = Corning™ SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

MULTIMODE Wavelength Bandwidth 1 GbE 10 GbE (nm) (MHz) Dist (m) Dist (m)

G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___

G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___

G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___

G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___

6 FIBER COUNT

001 to 024 fibers

1

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

MULTIMODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, or CE M2 = 3.5/1.0 850/1300 OM1 (62.5μm)

E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, CE, B1 or B2 M3 = 3.0/1.0 850/1300 OM2+, OM3, OM4 (50μm)

Other cable constructions and fiber performance grades available on request.

Example: ezMICROUNITUBE, single armor single jacket with 12 single-mode fibers (printed in feet)

7 FIBER GRADE

DR

OP

Page 68: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

68

MIC

RO

DU

CT

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom 50

0A D

S064

EZ

MIC

RO

DU

CT 0

3-18

ezMICRODUCT™Jetted microduct loose tube cable

Jacket (optimized for Jetting)

Ripcord

Water Blocking Elements

Gel-Filled Buffer Tube Containing up to 12 Fibers

Central Strength Member

RUSLISTED

Features and Benefits Optimal Jetting Performance - Reduced size and weight for installation in microduct - Up to 65% reduction in cross-section vs. conventional - Demonstrated results more than 1-1/4 miles (single) and 6 miles (cascaded) - Simple and standard loose tube entry via ripcords, swellable binders, and flexible buffer tubes Reduced Total Installed Cost - Reduce total Installed Cost - Defer CAPEX by maximizing duct utilization - Reduce installation and upgrade costs - Minimize disruption to underground infrastructure - Quick installation - long lengths and high speeds

- Allow use of ducts already containing cable - Microduct options available with mid-span express buffer tube storage capabilities up to 20 feet depending on the design (see table below).

Minimum Microduct ID (mm)

Optimum Microduct ID (mm)

Part Number Family

FiberCount

# Tube/Filler

# Fibers/

Tube

Tube Size

(mm)TubeType

SMFMaximum

Express TubeStorage (ft)

Cable Diameter

inches (mm)

Cable Weight

lb/kf (kg/km)

Bend Radiuswith Load

inches (cm)

Bend RadiusNo Load

inches (cm)

Tensile LoadMaximum / Opertating

(lbf)

8 10 MD11JKT-12 2 - 60 5 12 1.9 PBT 0 0.26 (6.7) 22 (32) 5 (13) 4 (10) 100/30

10 10 MDS1JKT-12 2 - 72 6 12 1.9 PBT 0 0.28 (7.0) 28 (41) 6 (14) 4 (11) 300/90

12 12 MDS1JKT-12 74 - 96 8 12 1.9 PBT 0 0.33 (8.4) 42 (62) 7 (17) 5 (13) 300/90

13 13 MDL1JKT-12 2 - 72 6 12 2.5 PP 20 0.35 (8.9) 42 (63) 7 (18) 5 (13) 300/90

13 13 MDL1JKT-12 74 - 84 7 12 2.5 PP 20 0.38 (9.7) 47 (69) 8 (20) 5 (15) 300/90

13 14 MDL1JKT-12 86 -96 8 12 2.5 PP 20 0.41 (10.5) 55 (82) 8 (21) 5 (16) 300/90

13 14 MDS1JKT-24 98 - 144 6 24 3.0 PBT 16 0.41 (10.5) 60 (89) 8 (21) 6 (16) 300/90

10 12 MDM1JKT-24 96 - 144 6 24 2.2 PBT 8 0.30 (7.7) 42 (62) 6 (16) 5 (12) 300/90

12 12 MDM1JKT-12 96 - 144 12 12 1.5 PBT 8 0.34 (8.6) 42 (63) 7 (17) 5 (13) 300/90

13 14 MDM1JKT-12 216 - 288 24 12 1.5 PBT 8 0.40 (10.1) 55 (82) 10 (25) 6 (15) 375/112

13 14MDM1JKT + Tone Wire

216 - 300 26 12 1.5 PBT 8 0.41 (10.6) 68 (101) 10 (26) 6 (16) 375/112

Installation note: Cables should be blown, not pulled. * The optimum duct size may provide longer blowing distances and/or provides a larger margin of error from unexpected tube deformations

Optimized for jetted microduct installations OverviewPrysmian’s ezMICRODUCT cables provide optimized jetting performance for underground microduct installations or jetting directly over existing cable. Prysmain offers microduct product solutions for microducts ranging from 8 mm to 13 mm, or larger, inside diameters. These small diameter cables combine high reliability with reduced size and weight for optimum blowing performance. With this approach, network operators can maximize duct utilization, defer capital expenditures to match revenue streams, maintain flexibility for future growth, and reduce installation and upgrade costs. Product Snapshot Applications Jetted microduct deployment, installed in microducts or partially filled duct Constructions Stranded dielectric loose tube/specialized jacket and construction Fiber Count 2 to 288 fibers in color coded buffer tubes Fiber Types Bend-insensitive SMF and multimode Performance ANSI/ICEA 744, IEC, RUS, GR-20 Options Tonewire Registered ISO 9001, ISO 14001, TL 9000 Supplier and OHSAS 18001

TH

E U S A /C A NADA

MANUFACTURED IN

Page 69: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

69

500A

DS0

64 E

ZM

ICR

OD

UCT

03-

18

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2018 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued March 2018.

Part Number Family

FiberCount

TEMPERATURE RANGE CompressionN/cm per ICEA640,

GR20

Impact Energy

Nom (FOTP25)Operating oF (oC) Installation oF (oC)

MD11JKT-12 2 - 60 -40 to +158 (-40 to +70) -22 to +140 (-30 to +60) 220 4.4

MDS1JKT-12 2 - 72 -40 to +158 (-40 to +70) -22 to +140 (-30 to +60) 220 4.4

MDS1JKT-12 74 - 96 -40 to +158 (-40 to +70) -22 to +140 (-30 to +60) 220 4.4

MDL1JKT-12 2 - 72 -40 to +158 (-40 to +70) -22 to +140 (-30 to +60) 220 4.4

MDL1JKT-12 74 - 84 -40 to +158 (-40 to +70) -22 to +140 (-30 to +60) 220 4.4

MDL1JKT-12 86 - 96 -40 to +158 (-40 to +70) -22 to +140 (-30 to +60) 220 4.4

MDS1JKT-24 98 - 144 -40 to +158 (-40 to +70) -22 to +140 (-30 to +60) 220 4.4

MDM1JKT-24 96 - 144 -22 to +158 (-30 to +70) +14 to +122 (-10 to +50) 100 4.4

MDM1JKT-12 144 -22 to +158 (-30 to +70) +14 to +122 (-10 to +50) 100 4.4

MDM1JKT-12 216 - 288 -22 to +158 (-30 to +70) +14 to +122 (-10 to +50) 100 4.4

Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described in the example.

Example: ezMICRODUCT loose tube cable | single jacket dielectric (12 fibers/tube) with 72 single-mode fibers (printed in feet)

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

MDS = ezMICRODUCT™ (BIF ONLY)

MD1 = ezMICRODUCT™ 100 (BIF ONLY)

MDL = ezMICRODUCT™ with 2.5 mm polypropylene tubes

MDM = ezMICRODUCT™ with 1.5 mm 12f tubes (BIF ONLY)

MDM = ezMICRODUCT™ with 2.2 mm 24f tubes (BIF ONLY)

3 CONSTRUCTION

1JKT = Single Jacket

4 FIBER GROUPING

12 = 12f per tube

24 = 24f per tube (12 fibers per unit)

F MDS 1JKT 12 B1 072 E3

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

CU = Corning™ Ultra Single-Mode (ITU G.657.A1 & G.652.D)

* MULTIMODE Wavelength Bandwidth 1 GbE 10 GbE (nm) (MHz) Dist (m) Dist (m)

G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___

G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___

G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___

G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___

6 FIBER COUNT

002 to 288 fibers

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Type

E3 = 0.35/0.35/0.25 1310/1383/1550 B1, B2, or CU

* MULTIMODE Attenuation (dB/km) Wavelength (nm)

M2 = 3.5/1.0 850/1300

M3 = 3.0/1.0 850/1300

1

Other cable constructions and fiber performance grades available on request.

* Multimode fiber is restricted to MDS1JKT and MDL1JKT designs

ProductTube Size

(mm)RecommendedMid-Span Tool

MD11JKT-12

1.9

Prysmian Buffer Tube Midspan Access Tool, 1.9

mm insert (20021564)or Prysmian 1.9mm

Buffer Tube Slitter Tool (9000090000)

MDS1JKT-12

MDS1JKT-24 3.0Prysmian Buffer Tube

Midspan Access Tool, 3.0 mm insert (20021570)

MDL1JKT-12 2.5

Prysmian Buffer Tube Midspan Access Tool, 2.5

mm insert or Prysmian 2.5 mm Buffer Tube Slitter Tool

(9000090001)

MDM1JKT-12 1.5Ripley Miller MSAT16

(MB01-7000) Tool, use 1.5 mm setting #4

MICR

OD

UCT

Page 70: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

70

FIG

UR

E-8

500A

DS1

20 A

ERO

LIN

K 1

0-16

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

MANUFACTURED IN

AeroLink™ Figure-8Self-supporting cable

Features and Benefits Integral Stranded, Galvanized Steel Messenger - Self-supporting design requires no over-lashing, allowing installation in a single pass - Standard 1/4" EHS (6.6M) galvanized strand - Web, jacket and strand dimensions sized for standard hardware Dry Water-Blocking Technology - Available with gel or dry buffer tubes - Permits rapid cable preparation and termination - Water-blocking materials are easily removed Flexible Buffer Tubes - Enhanced kink resistance and increased flexibility - Facilitates route management in closures - Eliminates need for closure transportation tubes Medium Density Polyethylene Jacket - Low friction installation - Excellent protection from environmental hazards - Embedded stripe on outer jacket available for additional cable identification Sheath Markings - Provide positive identification and length verification - Custom print available

Reverse Oscillated Lay Stranding Method - Facilitates access of fibers

Performance - Meets or exceeds the requirements of Telcordia GR-20, ICEA 640, and RUS PE90 - Tested in accordance with relevant EIA/TIA-455 series FOTPs for fiber optic cables

Registered Supplier - ISO 9001, ISO 14001, TL 9000 and OHSAS 18001

PERFORMANCE SPECIFICATIONS Bend RadiusDynamic 20 x Cable OD

Static 10 x Cable OD

Tensile Rating N lbf

MRCL with Messenger* 14,923 3350

Cable Installation w/o Messenger 2,700 600

Cable Residual w/o Messenger 800 180

Crush Resistance N/cm lbf/inShort/ long Term 220/110 125/63

Temperature Ratings °C °F

Operation -40 to +70 -40 to +158

Installation -30 to +60 -22 to +140

Storage/Shipping -40 to +75 -40 to +167

* Installation load should be lower than Maximum Rated Cable Load to allow for wind and ice loading in accordance with NESC guidelines.

1/4" Galvanized Steel Strand (6.6M)

Dry or Gel Buffer Tube with Optical Fibers

MDPE Outer Jacket

Water Blocking Tape

Ripcord

Jacket Web

Central Strength Member

RUSLISTED

Page 71: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

71

FIGU

RE-8

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS1

20 A

ERO

LIN

K 1

0-16

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2016 All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless authorized by Prysmian Group. Issued October 2016.

*Typical Sag Values are for a 150 foot span installed at the listed tensions

Nominal Design ParametersFiber Count 2-60 62-72 74-96 98-144 146-216

Buffer Tube Count 5 6 8 12 18

Max. Fiber/Tube 12 12 12 12 12

Buffer Tube OD(mm) 2.5 2.5 2.5 2.5 2.5

(inches) 0.098 0.098 0.098 0.098 0.098

Cable OD(mm) 10.1 x 21.8 10.9 x 22.6 12.6 x 24.3 15.9 x 27.6 15.9 x 27.6

(inches) 0.40 x 0.86 0.43 x 0.89 0.50 x 0.96 0.63 x 1.09 0.63 x 1.09

Cable Weight | Dry (F8D)(kg/km) 282 293 315 374 374(lb/kft) 189 197 212 251 251

Cable Weight | Gel (F8A)(kg/km) 287 299 323 392 397(lb/kft) 193 201 217 263 267

Max. Length(m) 10,380 9,749 7,989 5,768 5,615(ft) 35,522 31,977 26,204 18,919 18,417

Sag*@750 lbs (ft) 0.78 0.81 0.88 1.07 1.04@1000 lbs (ft) 0.58 0.61 0.66 0.80 0.78@1250 lbs (ft) 0.47 0.49 0.53 0.64 0.62

Example: 36 count AeroLinkTM dry, figure-8 cable with G.652.D LWP single-mode fiber and 0.35/0.35/0.25 attenuation.

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 C & D)

CE = Corning™ SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

TU = TeraLight Ultra Single-Mode (ITU G.655 & G.656)

LE = LEAF NZDSF (ITU G.655)

MULTIMODE Wavelength Bandwidth 1 GbE 10 GbE (nm) (MHz) Dist (m) Dist (m)

G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___

G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___

G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___

G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___

6 FIBER COUNT

002 to 216 fibers

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

F8D = AeroLink™ Figure-8 (Dry Tubes)

F8A = AeroLink™ Figure-8 (Gel Tubes)

3 CONSTRUCTION

1JKT = Single Jacket

4 FIBER GROUPING

12 = 12f per tube

F F8D 1JKT 12 HB 036 E3

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE1

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, or CE

E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, CE, BB, or BX

NA = 0.40/0.25 1310/1550 TeraLight Ultra Single-Mode

N1 = 0.25 1550 LEAF Single-Mode

MULTIMODE Attenuation (dB/km) Wavelength (nm)

M2 = 3.5/1.0 850/1300

M3 = 3.0/1.0 850/1300

Other cable constructions and fiber performance grades available on request.

Note: Please refer to the Fiber Code Addendum for additional fiber options, or contact us for help.

Page 72: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

72

FIG

UR

E-8

500N

DS1

21 A

ERO

LIN

K A

RM

OR

ED 1

0-16

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

AeroLink™ Figure 8 ArmoredSelf-supporting cable

MANUFACTURED IN

1/4" Galvanized Steel Strand (6.6M)

Jacket Web

MDPE Outer Jacket

Dry or Gel Buffer Tube with up to 12 Optical Fibers

Water Blocking Tape

Corrugated Steel Armor

Central Strength Member

Ripcord

Features and Benefits Integral Stranded, Galvanized Steel Messenger - Self-supporting design requires no over-lashing, allowing installation in a single pass - Standard 1/4" EHS (6.6M) galvanized strand - Web, jacket and strand dimensions sized for standard hardware Dry Water-Blocking Technology - Available with gel or dry buffer tubes - Permits rapid cable preparation and termination - Water-blocking materials are easily removed Flexible Buffer Tubes - Superior kink resistance and increased flexibility - Facilitates route management in closures - Eliminates need for closure transportation tubes Medium Density Polyethylene Jacket - Low friction installation - Excellent protection from environmental hazards - Embedded stripe on outer jacket available for additional cable identification Sheath Markings - Provide positive identification and length verification - Custom print available Reverse Oscillated Lay Stranding Method - Facilitates access of fibers

Performance - Meets or exceeds the requirements of Telcordia GR-20, ICEA 640, and RUS PE90 - Tested in accordance with relevant EIA/TIA-455 series FOTPs for fiber optic cables

Registered Supplier - ISO 9001, ISO 14001, TL 9000 and OHSAS 18001

PERFORMANCE SPECIFICATIONS Bend RadiusDynamic 20 x Cable OD

Static 10 x Cable OD

Tensile Rating N lbf

MRCL with Messenger* 14,923 3350

Cable Installation w/o Messenger 2,700 600

Cable Residual w/o Messenger 800 180

Crush Resistance N/cm lbf/inShort/ long Term 220/110 125/63

Temperature Ratings °C °F

Operation -40 to +70 -40 to +158

Installation -30 to +60 -22 to +140

Storage/Shipping -40 to +75 -40 to +167

RUSLISTED

Page 73: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

73

FIGU

RE-8

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500N

DS1

21 A

ERO

LIN

K A

RM

OR

ED 1

0-16

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2016 All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless authorized by Prysmian Group. Issued October 2016.

Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below

*Typical Sag Values are for a 150 foot span installed at the listed tensions

Nominal Design ParametersFiber Count 2-60 62-72 74-96 98-144 146-216

Buffer Tube Count 5 6 8 12 18

Max. Fiber/Tube 12 12 12 12 12

Buffer Tube OD(mm) 2.5 2.5 2.5 2.5 2.5

(inches) 0.098 0.098 0.098 0.098 0.098

Cable OD(mm) 11.8 x 23.5 12.6 x 24.3 14.3 x 26.0 17.6 x 29.3 17.9 x 29.6

(inches) 0.46 x 0.93 0.50 x 0.96 0.560 x 1.02 0.69 x 1.15 0.70 x 1.17

Cable Weight | Dry (F8D)(kg/km) 350 363 404 480 480(lb/kft) 235 244 271 232 323

Cable Weight | Gel (F8A)(kg/km) 355 375 398 498 498(lb/kft) 239 252 267 355 335

Max. Length(m) 10,693 8,726 7,267 5,102 4,975(ft) 35,073 28,621 23,826 16,735 16,318

Sag* @750 lbs (ft) 0.89 0.95 1.03 1.27 1.25 @1000 lbs (ft) 0.67 0.72 0.77 0.95 0.94 @1250 lbs (ft) 0.53 0.57 0.62 0.76 0.75

Example: If you need a 36 count AeroLinkTM Dry Figure-8 Armored Cable with G.652.D LWP Single-Mode fiber and 0.35/0.35/0.25 attenuation.

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 C & D)

CE = Corning™ SMF28e+ Single-Mode

BB = BendBright Single-Mode (ITU G.657.A1 & G.652.D)

BX = BendBrightXS Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

TU = TeraLight Ultra Single-Mode (ITU G.655 & G.656)

LE = LEAF NZDSF (ITU G.655)

MULTIMODE Wavelength Bandwidth 1 GbE 10 GbE (nm) (MHz) Dist (m) Dist (m)

G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___

G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___

G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___

G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___

6 FIBER COUNT

002 to 216 fibers

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

F8D = AeroLink™ Figure 8 (Dry Tubes)

F8A = AeroLink™ Figure 8 (Gel Tubes)

3 CONSTRUCTION

1A1J = Single Armor, Single Jacket

4 FIBER GROUPING

12 = 12f per unit or tube

F F8D 1A1J 12 HB 036 E3

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE1

7 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, or CE

E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, CE, BB, or BX

NA = 0.40/0.25 1310/1550 TeraLight Ultra Single-Mode

N1 = 0.25 1550 LEAF Single-Mode

MULTIMODE Attenuation (dB/km) Wavelength (nm)

M2 = 3.5/1.0 850/1300

M3 = 3.0/1.0 850/1300

Other cable constructions and fiber performance grades available on request.

Note: Please refer to the Fiber Code Addendum for additional fiber options, or contact us for help.

Page 74: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

74

500A

DS0

62 E

ZSP

AN

AD

SS 0

5-18

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

ezSPAN® ADSSAll-dielectric self-supporting loose tube cable

MANUFACTURED IN

RUSLISTED

All-Dielectric Self-Support (ADSS) easy entry fiber cable for up to 1200' (365m) spans typical in distribution. Overview Prysmian’s ezSPAN® ADSS provides reliable self-support performance for up to 1200 feet (365 meters). Each ezSPAN® ADSS cable is custom engineered for each application based on its full weather load, ensuring safe, reliable lifetime performance. Flexible buffer tubes enable ease of mid-entry, preparation and routing in splice closures. These cables uniquely combine flexible buffer tubes and swellable water-blocking to make ezSPAN the easiest ADSS cables to prep and access.

Product Snapshot Applications Self-supporting aerial deployment for communications & power transmission Constructions All-dielectric round - typical span lengths up to 1,200' (305m), single and dual jacket Fiber Count 12 to 144 fibers in color coded buffer tubes Fiber Types Single-mode / bend-insensitive / NZDSF / multimode / hybrid Standards IEEE 1222-2011, ANSI / ICEA 640, IEC, RUS 7 CFR 1755 (RUS LISTED), Telecordia GR-20 Registered ISO 9001, ISO 14001, TL 9000, Supplier and OHSAS 18001 Other Versions Long Span ADSS

Features and Benefits

Easy Cable Entry and Preparation - 12 fibers per tube construction up to 144 fiber designs allow easy termination and mid-span fiber access - Flexible buffer tubes and single jacket option enhance mid-entry - Ripcord speeds cable entry and outer jacket removal - Swellable binders speed cable preparation Flexible Routing and Termination - Flexible buffer tubes simplify routing, storage and prep - Available with G657.A1 and G657.A2 bend-insensitive single-mode fiber Versatile Installation and Use - Tailored designs span distances up to 1200’ (305m) without interrupting power - Easy mid-entry is ideal for FTTx distribution applications - Matching pole attachment hardware (dead-ends, suspension clamps) Reliable Lifetime Performance - Custom engineered for operation under full load - Guaranteed standards-based performance

Water Blocking Material

Aramid Strength Yarns

Inner Jacket Polyethylene (optional)

Gel-Filled Buffer Tube Containing up to 12 Fibers

Ripcord

Central Strength Member

AD

SS

Page 75: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

75

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

62 E

ZSP

AN

AD

SS 0

5-18

ezSPAN® ADSSAll-Dielectric Self-Supporting Loose Tube Cable

Temperature RangeShipping and Storage -40o F to +167o F (-40o C to +75o C)Installation -22o F to +140o F (-30o C to +60o C)Operation -40o F to +158o F (-40o C to +70o C)

Minimum Bend Radius With load: 20x cable diameter

No load: 10x cable diameter

PLP ATTACHMENT HARDWARE CONSIDERATIONS

- Dead-ends indicated are Limited & Medium Tension dead-ends. The Limited Tension dead-end is designed for a maximum long-term tension of 1000 lbs and short-term tension of 2500 lbs. The Medium Tension dead-end is designed for 2000 lbs for long-term tensions and 4000 lbs for short-term loads. Semi-high or High Tension dead-ends should be used for higher tension ratings. - Limited Tension dead ends are limited to a maximum span length of 600 feet. - C1E1 designates thimble clevis and extension link (recommended). - Aluminum Suspension is designed for in-line support with a maximum angle change of 20° and a maximum span of 600 feet. - Spans of > 600 to 1200 feet require reinforcing rods (SSR). - The “S” designates anchor shackle and eye-nut (recommended). - Vibration dampers may be required. - Aluminum support is designed for in-line support with a maximum angle change of 20° and a maximum span of 600 feet.

INSTALLATION SPECIFICATIONS

Maximum Stringing Tension: 600 lbs

AD

SS

Page 76: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

76

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

62 E

ZSP

AN

AD

SS 0

5-18

ezSPAN® ADSSAll-Dielectric Self-Supporting Loose Tube Cable

6-30 Fibers (6 fibers per tube)

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 430 0.393 465 1.5 F-ADSS0465-06-HB-XXX 2872000C1E1 4450198S - 4450098

12-60 Fibers (12 fibers per tube)

up to 328 0.398 415 1.5 F-ADSS0415-12-HB-XXX1 2872000C1E1 4450198S - 4450098

NESC Light Loading ezSPAN Single Jacket

12-72 Fibers

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 328 0.420 495 1.58 F-ADSS0495-12-HB-XXX 2872001C1E1 4450198S - 4450098

up to 600 0.482 1025 1.5 F-ADES1025-12-HB-XXX 2872004C1E1 4450200S 4470200S 4450100

700 0.482 1025 1.5 F-ADES1025-12-HB-XXX 2872100C1E1 4450200S 4470200S 4450100

800 0.483 1075 1.5 F-ADES1075-12-HB-XXX 2872100C1E1 4450200S 4470200S 4450100

900 0.486 1205 1.5 F-ADES1205-12-HB-XXX 2872100C1E1 4450200S 4470200S 4450100

1000 0.489 1345 1.5 F-ADES1345-12-HB-XXX 2872100C1E1 4450200S 4470200S 4450100

1100 0.491 1475 1.5 F-ADES1475-12-HB-XXX 2872100C1E1 4450200S 4470200S 4450100

1200 0.494 1615 1.5 F-ADES1615-12-HB-XXX 2872100C1E1 4450200S 4470200S 4450100

84-96 Fibers

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 600 0.567 1025 1.5 F-ADES1025-12-HB-XXX 2872006C1E1 4450201S 4470202S 4450101

700 0.568 1115 1.5 F-ADES1115-12-HB-XXX 2872102C1E1 4450201S 4470202S 4450101

800 0.571 1255 1.5 F-ADES1255-12-HB-XXX 2872102C1E1 4450201S 4470202S 4450101

900 0.574 1435 1.5 F-ADES1435-12-HB-XXX 2872102C1E1 4450201S 4470202S 4450101

1000 0.577 1615 1.5 F-ADES1615-12-HB-XXX 2872102C1E1 4450202S 4470202S 4450102

1100 0.580 1795 1.5 F-ADES1795-12-HB-XXX 2872103C1E1 4450202S 4470202S 4450102

1200 0.582 1925 1.5 F-ADES1925-12-HB-XXX 2872103C1E1 4450202S 4470202S 4450102

108-144 Fibers

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 400 0.733 1025 1.5 F-ADES1025-12-HB-XXX 2872010C1E1 4450204S 4470204S 4450104

500 0.734 1075 1.5 F-ADES1075-12-HB-XXX 2872010C1E1 4450204S 4470204S 4450104

600 0.737 1295 1.5 F-ADES1295-12-HB-XXX 2872010C1E1 4450204S 4470204S 4450104

700 0.740 1525 1.5 F-ADES1525-12-HB-XXX 2872107C1E1 4450204S 4470205S 4450104

800 0.742 1705 1.5 F-ADES1705-12-HB-XXX 2872107C1E1 4450204S 4470205S 4450104

900 0.745 1925 1.5 F-ADES1925-12-HB-XXX 2872107C1E1 4450204S 4470205S 4450104

1000 0.748 2155 1.5 F-ADES2125-12-HB-XXX 2872107C1E1 4450204S 4470205S 4450104

AD

SS

Page 77: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

77

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

62 E

ZSP

AN

AD

SS 0

5-18

ezSPAN® ADSSAll-Dielectric Self-Supporting Loose Tube Cable

6-30 Fibers (6 fibers per tube)

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

280 0.393 465 1.5 F-ADSS0465-06-HB-XXX 287500TE 4450198S - 4450098

NESC Medium Loading ezSPAN Single Jacket

12-72 Fibers

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 500 0.482 1025 1.5 F-ADES1025-12-HB-XXX 2872004C1E1 4450200S 4470200S 4450100

600 0.484 1115 1.5 F-ADES1115-12-HB-XXX 2872004C1E1 4450200S 4470200S 4450100

700 0.488 1295 1.5 F-ADES1295-12-HB-XXX 2872100C1E1 4450200S 4470200S 4450100

800 0.492 1525 1.5 F-ADES1525-12-HB-XXX 2872100C1E1 4450200S 4470200S 4450100

900 0.496 1705 1.5 F-ADES1705-12-HB-XXX 2872100C1E1 4450200S 4470200S 4450100

84-96 Fibers

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 500 0.567 1025 1.5 F-ADES1025-12-HB-XXX 2872006C1E1 4450201S 4470202S 4450101

600 0.571 1255 1.5 F-ADES1255-12-HB-XXX 2872006C1E1 4450201S 4470202S 4450101

700 0.575 1475 1.5 F-ADES1475-12-HB-XXX 2872102C1E1 4450201S 4470202S 4450101

800 0.578 1705 1.5 F-ADES1705-12-HB-XXX 2872103C1E1 4450202S 4470202S 4450102

900 0.582 1885 1.5 F-ADES1885-12-HB-XXX 2872103C1E1 4450202S 4470202S 4450102

108-144 Fibers

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 400 0.733 1025 1.5 F-ADES1025-12-HB-XXX 2872010C1E1 4450204S 4470204S 4450104

500 0.737 1295 1.5 F-ADES1295-12-HB-XXX 2872010C1E1 4450204S 4470204S 4450104

600 0.740 1565 1.5 F-ADES1565-12-HB-XXX 2872011C1E1 4450204S 4470205S 4450104

700 0.744 1835 1.5 F-ADES1835-12-HB-XXX 2872107C1E1 4450204S 4470205S 4450104

800 0.747 2105 1.5 F-ADES2105-12-HB-XXX 2872107C1E1 4450204S 4470205S 4450104

900 0.751 2375 1.5 F-ADES2375-12-HB-XXX 2872107C1E1 4450205S 4470205S 4450105

AD

SS

Page 78: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

78

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

62 E

ZSP

AN

AD

SS 0

5-18

ezSPAN® ADSSAll-Dielectric Self-Supporting Loose Tube Cable

6-30 Fibers (6 fibers per tube)

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

165 0.393 465 1.5 F-ADSS0465-06-HB-XXX 287500TE 4450198S - 4450098

NESC Heavy Loading ezSPAN Single Jacket

12-72 Fibers

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 330 0.482 1025 1.5 F-ADES1025-12-HB-XXX 2872004C1E1 4450200S 4470200S 4450100

350 0.483 1075 1.5 F-ADES1075-12-HB-XXX 2872004C1E1 4450200S 4470200S 4450100

400 0.487 1255 1.5 F-ADES1255-12-HB-XXX 2872004C1E1 4450200S 4470200S 4450100

450 0.490 1385 1.5 F-ADES1385-12-HB-XXX 2872004C1E1 4450200S 4470200S 4450100

500 0.492 1525 1.5 F-ADES1525-12-HB-XXX 2872004C1E1 4450200S 4470200S 4450100

550 0.496 1705 1.5 F-ADES1705-12-HB-XXX 2872004C1E1 4450200S 4470200S 4450100

600 0.500 1885 1.5 F-ADES1885-12-HB-XXX 2872004C1E1 4450200S 4470200S 4450100

700 0.506 2195 1.5 F-ADES2195-12-HB-XXX 2872100C1E1 4450200S 4470201S 4450100

84-96 Fibers

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 310 0.567 1025 1.5 F-ADES1025-12-HB-XXX 2872006C1E1 4450201S 4470202S 4450101

350 0.569 1165 1.5 F-ADES1165-12-HB-XXX 2872006C1E1 4450201S 4470202S 4450101

400 0.572 1345 1.5 F-ADES1345-12-HB-XXX 2872006C1E1 4450201S 4470202S 4450101

450 0.575 1525 1.5 F-ADES1525-12-HB-XXX 2872006C1E1 4450201S 4470202S 4450101

500 0.578 1705 1.5 F-ADES1705-12-HB-XXX 2872007C1E1 4450202S 4470202S 4450102

550 0.582 1885 1.5 F-ADES1885-12-HB-XXX 2872007C1E1 4450202S 4470202S 4450102

600 0.584 2015 1.5 F-ADES2015-12-HB-XXX 2872007C1E1 4450202S 4470202S 4450102

700 0.590 2375 1.5 F-ADES2375-12-HB-XXX 2872103C1E1 4450202S 4470202S 4450102

108-144 Fibers

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 250 0.733 1025 1.5 F-ADES1025-12-HB-XXX 2872010C1E1 4450204S 4470204S 4450104

300 0.736 1205 1.5 F-ADES1205-12-HB-XXX 2872010C1E1 4450204S 4470204S 4450104

350 0.738 1385 1.5 F-ADES1385-12-HB-XXX 2872010C1E1 4450204S 4470205S 4450104

400 0.741 1615 1.5 F-ADES1615-12-HB-XXX 2872011C1E1 4450204S 4470205S 4450104

450 0.743 1795 1.5 F-ADES1795-12-HB-XXX 2872011C1E1 4450204S 4470205S 4450104

500 0.746 1975 1.5 F-ADES1975-12-HB-XXX 2872011C1E1 4450204S 4470205S 4450104

550 0.748 2195 1.5 F-ADES2195-12-HB-XXX 2872011C1E1 4450204S 4470205S 4450104

600 0.751 2375 1.5 F-ADES2375-12-HB-XXX 2872011C1E1 4450205S 4470205S 4450105

AD

SS

Page 79: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

79

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

62 E

ZSP

AN

AD

SS 0

5-18

ezSPAN® ADSSAll-Dielectric Self-Supporting Loose Tube Cable

NESC Light Loading ezSPAN Double Jacket 12-72 Fibers

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 600 0.533 1031 1.5 F-ADED1031-12-HB-XXX 2872005C1E1 4450201S 4470201S 4450101

700 0.534 1071 1.5 F-ADED1071-12-HB-XXX 2872101C1E1 4450201S 4470201S 4450101

800 0.537 1211 1.5 F-ADED1211-12-HB-XXX 2872101C1E1 4450201S 4470201S 4450101

900 0.540 1391 1.5 F-ADED1391-12-HB-XXX 2872101C1E1 4450201S 4470201S 4450101

1000 0.542 1521 1.5 F-ADED1521-12-HB-XXX 2872101C1E1 4450201S 4470201S 4450101

1100 0.546 1701 1.5 F-ADED1701-12-HB-XXX 2872102C1E1 4450201S 4470201S 4450101

1200 0.549 1881 1.5 F-ADED1881-12-HB-XXX 2872102C1E1 4450201S 4470201S 4450101

1300 0.552 2021 1.5 F-ADED2021-12-HB-XXX 2872102C1E1 4450201S 4470202S 4450101

1400 0.555 2201 1.5 F-ADED2201-12-HB-XXX 2872102C1E1 4450201S 4470202S 4450101

1500 0.558 2381 1.5 F-ADED2381-12-HB-XXX 2872102C1E1 4450201S 4470202S 4450101

1600 0.561 2561 1.5 F-ADED2561-12-HB-XXX 2872102C1E1 4450201S 4470202S 4450101

84-96 Fibers

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 575 0.618 1031 1.5 F-ADED1031-12-HB-XXX 2872008C1E1 4450202S 4470202S 4450102

600 0.619 1071 1.5 F-ADED1071-12-HB-XXX 2872008C1E1 4450202S 4470202S 4450102

700 0.622 1251 1.5 F-ADED1251-12-HB-XXX 2872104C1E1 4450202S 4470202S 4450102

800 0.625 1431 1.5 F-ADED1431-12-HB-XXX 2872104C1E1 4450202S 4470202S 4450102

900 0.628 1661 1.5 F-ADED1661-12-HB-XXX 2872104C1E1 4450203S 4470203S 4450103

1000 0.631 1841 1.5 F-ADED1841-12-HB-XXX 2872104C1E1 4450203S 4470203S 4450103

1100 0.634 2021 1.5 F-ADED2021-12-HB-XXX 2872104C1E1 4450203S 4470203S 4450103

1200 0.636 2201 1.5 F-ADED2201-12-HB-XXX 2872104C1E1 4450203S 4470203S 4450103

1300 0.640 2421 1.5 F-ADED2421-12-HB-XXX 2872104C1E1 4450203S 4470203S 4450103

1400 0.643 2621 1.5 F-ADED2621-12-HB-XXX 2872104C1E1 4450203S 4470203S 4450103

108-144 Fibers

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 425 0.785 1031 1.5 F-ADED1031-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105

500 0.787 1211 1.5 F-ADED1211-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105

600 0.791 1481 1.5 F-ADED1481-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105

700 0.793 1701 1.5 F-ADED1701-12-HB-XXX 2872108C1E1 4450205S 4470205S 4450105

800 0.796 1971 1.5 F-ADED1971-12-HB-XXX 2872108C1E1 4450205S 4470205S 4450105

900 0.799 2201 1.5 F-ADED2201-12-HB-XXX 2872108C1E1 4450205S 4470205S 4450105

1000 0.802 2471 1.5 F-ADED2471-12-HB-XXX 2872108C1E1 4450205S 4470205S 4450105

1100 0.806 2751 1.5 F-ADED2751-12-HB-XXX 2872108C1E1 4450205S 4470205S 4450105

AD

SS

Page 80: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

80

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

62 E

ZSP

AN

AD

SS 0

5-18

ezSPAN® ADSSAll-Dielectric Self-Supporting Loose Tube Cable

NESC Medium Loading ezSPAN Double Jacket 12-72 Fibers

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 500 0.533 1031 1.5 F-ADED1031-12-HB-XXX 2872005C1E1 4450201S 4470201S 4450101

600 0.537 1211 1.5 F-ADED1211-12-HB-XXX 2872005C1E1 4450201S 4470201S 4450101

700 0.541 1431 1.5 F-ADED1431-12-HB-XXX 2872101C1E1 4450201S 4470201S 4450101

800 0.545 1661 1.5 F-ADED1661-12-HB-XXX 2872102C1E1 4450201S 4470201S 4450101

900 0.549 1881 1.5 F-ADED1881-12-HB-XXX 2872102C1E1 4450201S 4470201S 4450101

1000 0.553 2111 1.5 F-ADED2111-12-HB-XXX 2872102C1E1 4450201S 4470202S 4450101

1100 0.556 2291 1.5 F-ADED2291-12-HB-XXX 2872102C1E1 4450201S 4470202S 4450101

84-96 Fibers

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 450 0.618 1031 1.5 F-ADED1031-12-HB-XXX 2872008C1E1 4450202S 4470202S 4450102

500 0.620 1161 1.5 F-ADED1161-12-HB-XXX 2872008C1E1 4450202S 4470202S 4450102

600 0.624 1391 1.5 F-ADED1391-12-HB-XXX 2872008C1E1 4450202S 4470202S 4450102

700 0.627 1611 1.5 F-ADED1611-12-HB-XXX 2872104C1E1 4450203S 4470203S 4450103

800 0.631 1841 1.5 F-ADED1841-12-HB-XXX 2872104C1E1 4450203S 4470203S 4450103

900 0.635 2111 1.5 F-ADED2111-12-HB-XXX 2872104C1E1 4450203S 4470203S 4450103

1000 0.638 2331 1.5 F-ADED2331-12-HB-XXX 2872104C1E1 4450203S 4470203S 4450103

1100 0.643 2621 1.5 F-ADED2621-12-HB-XXX 2872104C1E1 4450203S 4470203S 4450103

108-144 Fibers

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 350 0.785 1031 1.5 F-ADED1031-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105

400 0.787 1161 1.5 F-ADED1161-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105

500 0.790 1431 1.5 F-ADED1431-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105

600 0.794 1751 1.5 F-ADED1751-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105

700 0.797 2021 1.5 F-ADED2021-12-HB-XXX 2872108C1E1 4450205S 4470205S 4450105

800 0.801 2331 1.5 F-ADED2331-12-HB-XXX 2872108C1E1 4450205S 4470205S 4450105

900 0.804 2621 1.5 F-ADED2621-12-HB-XXX 2872108C1E1 4450205S 4470205S 4450105

AD

SS

Page 81: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

81

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

62 E

ZSP

AN

AD

SS 0

5-18

ezSPAN® ADSSAll-Dielectric Self-Supporting Loose Tube Cable

NESC Heavy Loading ezSPAN Double Jacket 12-72 Fibers

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 300 0.533 1031 1.5 F-ADED1031-12-HB-XXX 2872005C1E1 4450201S 4470201S 4450101

350 0.536 1161 1.5 F-ADED1161-12-HB-XXX 2872005C1E1 4450201S 4470201S 4450101

400 0.539 1341 1.5 F-ADED1341-12-HB-XXX 2872005C1E1 4450201S 4470201S 4450101

450 0.542 1481 1.5 F-ADED1481-12-HB-XXX 2872005C1E1 4450201S 4470201S 4450101

500 0.545 1661 1.5 F-ADED1661-12-HB-XXX 2872006C1E1 4450201S 4470201S 4450101

550 0.548 1841 1.5 F-ADED1841-12-HB-XXX 2872006C1E1 4450201S 4470201S 4450101

600 0.552 2021 1.5 F-ADED2021-12-HB-XXX 2872006C1E1 4450201S 4470202S 4450101

650 0.555 2201 1.5 F-ADED2201-12-HB-XXX 2872102C1E1 4450201S 4470202S 4450101

700 0.558 2381 1.5 F-ADED2381-12-HB-XXX 2872102C1E1 4450201S 4470202S 4450101

750 0.560 2511 1.5 F-ADED2511-12-HB-XXX 2872102C1E1 4450201S 4470202S 4450101

84-96 Fibers

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 290 0.618 1031 1.5 F-ADED1031-12-HB-XXX 2872008C1E1 4450202S 4470202S 4450102

300 0.619 1071 1.5 F-ADED1071-12-HB-XXX 2872008C1E1 4450202S 4470202S 4450102

350 0.622 1251 1.5 F-ADED1251-12-HB-XXX 2872008C1E1 4450202S 4470202S 4450102

400 0.625 1431 1.5 F-ADED1431-12-HB-XXX 2872008C1E1 4450202S 4470202S 4450102

450 0.627 1611 1.5 F-ADED1611-12-HB-XXX 2872008C1E1 4450203S 4470203S 4450103

500 0.631 1841 1.5 F-ADED1841-12-HB-XXX 2872008C1E1 4450203S 4470203S 4450103

550 0.634 2021 1.5 F-ADED2021-12-HB-XXX 2872008C1E1 4450203S 4470203S 4450103

600 0.636 2201 1.5 F-ADED2201-12-HB-XXX 2872008C1E1 4450203S 4470203S 4450103

650 0.639 2381 1.5 F-ADED2381-12-HB-XXX 2872104C1E1 4450203S 4470203S 4450103

700 0.642 2561 1.5 F-ADED2561-12-HB-XXX 2872104C1E1 4450203S 4470203S 4450103

108-144 Fibers

PLP Attachment Hardware Part #

Span Distance (ft)

Cable Outside Diameter (in)

Maximum RatedCable Load

(MRCL) (lbs)Initial

Sag (%)*Cable Part Numbers Dead End

Al Suspension w/o SSR (< 600 ft)

Al Suspension with SSR

Al Support Spans

< 600 ft

up to 240 0.785 1031 1.5 F-ADED1031-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105

250 0.786 1071 1.5 F-ADED1071-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105

300 0.788 1301 1.5 F-ADED1301-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105

350 0.791 1521 1.5 F-ADED1521-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105

400 0.794 1751 1.5 F-ADED1751-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105

450 0.796 1931 1.5 F-ADED1931-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105

500 0.798 2157 1.5 F-ADED2157-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105

550 0.801 2381 1.5 F-ADED2381-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105

600 0.804 2621 1.5 F-ADED2621-12-HB-XXX 2872108C1E1 4450205S 4470205S 4450105

AD

SS

Page 82: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

82

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

62 E

ZSP

AN

AD

SS 0

5-18

ezSPAN® ADSSAll-Dielectric Self-Supporting Loose Tube Cable

ORDERING CHECK LIST

1 Installation Location: City _____________________________ State ___________

2 Cable Length Marking £ Feet £ Meters

3 # of Jackets: £ Single Jacket £ Dual Jacket

4 Number of Fibers: _______________

5 Fiber Type & Grade: _______________

6 Max. Span Length: (ft or m) _______________

7 Installation Sag: £ 1.5% £ Other (Please Specify) _____________

8 NESC Loading Condition: £ Light £ Medium £ Heavy

£ Other (Define Ice & Wind Load) __________________

9 Line Voltage: £ None £ Distribution Line

Transmission Line ______ Phase to Phase (kV) ______ Phase to Ground _______

10 Fiber Strain: £ Safe Strain £ Zero Strain

AD

SS

Page 83: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

83

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

500A

DS0

62 E

ZSP

AN

AD

SS 0

5-18

Ordering Guide

The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below

F ADE S XXXX 12 HB 144 E3

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 5 FIBER GROUPING 6 FIBER TYPE4 LOAD

RATING

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

ADE = ezSpan ADSS

ADS = Short Span ADSS

3 CONSTRUCTION

S = Single Jacket

D = Double Jacket

4 LOAD RATING

Max Rated Cable Load (lbs)

5 FIBER GROUPING

12 = 12f per tube

FIBER INFORMATION

6 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 C & D)

CE = Corning™ SMF28e+ Single-Mode

B1 = Bend-Insenitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insenitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

TU = TeraLight™ Ultra Single-Mode (ITU G.655 & G.656)

LE = LEAF NZDSF (ITU G.655)

MULTIMODE Wavelength Bandwidth 1 GbE 10 GbE (nm) (MHz) Dist (m) Dist (m)

G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___

G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___

G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___

G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___

7 FIBER COUNT

004 to 144 fibers

8 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, or CE

E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, CE, B1, or B2

NA = 0.40/0.25 1310/1550 TeraLight™ Ultra Single-Mode

N1 = 0.25 1550 LEAF Single-Mode

MULTIMODE Attenuation (dB/km) Wavelength (nm)

M2 = 3.5/1.0 850/1300

M3 = 3.0/1.0 850/1300

Other cable constructions and fiber performance grades available on request.

7 FIBER COUNT 8 FIBER GRADE1

Example: ezSpan™ ADSS | single jacket (12 fibers/tube) with 144 single-mode fibers (printed in feet)

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2018 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued May 2018.

AD

SS

Page 84: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

84

AD

SS

500A

DS0

63 L

ON

G S

PAN

AD

SS 1

-17

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

MANUFACTURED IN

Long Span ADSSAll-dielectric self-supporting loose tube cable

Water Blocking Tube

Aramid Strength Yarns

Inner Jacket Polyethylene (optional)

HDPE Outer Jacket

Gel-Filled Buffer Tube Material

Ripcord

All-Dielectric Self-Support (ADSS) fiber cable for up to 2600' (800m) spans common in transmission. OverviewPrysmian’s Long Span ADSS version provides reliable self-support performance for up to 2,600 feet (800 meters). Each Long Span ADSS cable is custom engineered for optimum placement on utility towers and to operate under full weather load, ensuring safe reliable lifetime performance. For installation on high-voltage lines up to 275 kV, an optional track-resistant jacket prevents dry-band arcing damage. Available up to 288 fibers, cables greater than 72 fibers utilize a 24 fiber per tube design to reduce environmental load (12 fibers per tube design is also available for fiber counts of 84-144). Product Snapshot Applications Self-supporting aerial deployment for communications & power transmission space Constructions All-dielectric round - typical span lengths up to 2,600’ (800m), single and dual jacket, and track resistant Fiber Count 12 to 288 fibers in color-coded buffer tubes Fiber Types Single-mode /bend-insensitive/ NZDSF / multimode / hybrid Options Track resistant jacket, SafeStrain or ZeroStrain designs Performance IEEE 1222-2011, ANSI / ICEA 640, RUS 7 CFR 1755 (RUS LISTED), Telecordia GR-20 IEC 60794-4-20 Registered ISO 9001, ISO 14001, TL 9000, Supplier and OHSAS 18001 Other Versions ezSPAN ADSS

Features and Benefits Proven Long Span Installation & Use - Tailored designs span distances up to 2,600' (800m) without interrupting power - Higher count designs utilize 24 fiber per tube to reduce diameter and environmental loading

Easy Cable Entry & Preparation - Ripcord speeds cable entry & outer jacket removal - Swellable binders speed cable preparation - Available bend-insensitive single-mode fiber - 2.6 mm tube with 12 fibers per tube; 3.0 mm tube with 24 fibers per tube (with two 12 fiber binder groups)

Reliable Lifetime Performance - Custom engineered for operation under full load - Available with zero fiber strain at the maximum rated cable load (MRCL) or with a SafeStrain design limiting fiber strain to 0.20%. - Guaranteed standards-based performance

Temperature RangeShipping and Storage: -40o F to +167o F (-40o C to +75o C)Installation: -22o F to +140o F (-30o C to +60o C)

Operation: -40o F to +158o F (-40o C to +70o C)

Minimum Bend Radius With load: 20x cable diameter

No load: 10x cable diameter

INSTALLATION SPECIFICATIONS

Central Strength Member

RUSLISTED

Page 85: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

85

AD

SS

500A

DS0

63 L

ON

G S

PAN

AD

SS 1

-17

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

Long Span ADSSAll-Dielectric Self-Supporting Loose Tube Cable

Temperature RangeShipping and Storage: -40o F to +167o F (-40o C to +75o C)Installation: -22o F to +140o F (-30o C to +60o C)

Operation: -40o F to +158o F (-40o C to +70o C)

Minimum Bend Radius With load: 20x cable diameter

No load: 10x cable diameter

INSTALLATION SPECIFICATIONS

PLP ATTACHMENT HARDWARE CONSIDERATIONS - Dead-ends indicated are Limited & Medium Tension dead-ends. The Limited Tension dead-end is designed for a maximum long-term tension of 1000 lbs and short-term tension of 2500 lbs. The Medium Tension dead-end is designed for 2000 lbs for long-term tensions and 4000 lbs. for short-term loads. Semi-High or High Tension dead-ends should be used for higher tension ratings. - Limited tension dead ends are limited to a maximum span length of 600 feet. - C1E1 designates thimble clevis and extension link (recommended). - Aluminum suspension is designed for in-line support with a maximum angle change of 20° and a maximum span of 600 feet. - Spans of > 600 to 1200 feet require reinforcing rods (SSR). - The “S” designates anchor shackle and eye-nut (recommended). - Vibration dampers are recommended. - Aluminum support is designed for in-line support with a maximum angle change of 20° and a maximum span of 600 feet.

Page 86: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

86

AD

SS

500A

DS0

63 L

ON

G S

PAN

AD

SS 1

-17

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

Long Span ADSSAll-Dielectric Self-Supporting Loose Tube Cable

84 to 144F

Span Distance(ft)

Cable Part Number

Maximum RateCable Load

(MRCL) (lbf)

Cable OD

(inches)

Installation Load (lbf)

InstallationSag Dead End

Al Support < 600 ft

Span

Al Suspension w/o SSR (< 600 ft)

Al Suspension

with SSR

up to 600 ADLS1025-24-HB-XXX 1025 0.492 491 1.5 2872004C1E1 4450100 4450200S 4470200S

700 ADLS1025-24-HB-XXX 1025 0.492 491 1.5 2872100C1E1 4450100 4450200S 4470200S

800 ADLS1115-24-HB-XXX 1115 0.494 565 1.5 2872100C1E1 4450100 4450200S 4470200S

900 ADLS1295-24-HB-XXX 1295 0.498 644 1.5 2872100C1E1 4450100 4450200S 4470200S

Single HDPE Jacket (without track resistance) SafeStrain Design | ADLSNESC Light Load6-72 fibers ezSPAN ADSS design is recommended

156 to 216F

Span Distance(ft)

Cable Part Number

Maximum RateCable Load

(MRCL) (lbf)

Cable OD

(inches)

Installation Load (lbf)

InstallationSag Dead End

Al Support < 600 ft

Span

Al Suspension w/o SSR (< 600 ft)

Al Suspension

with SSR

up to 500 ADLS1025-24-HB-XXX 1025 0.616 500 1.5 2872008C1E1 4450102 4450202S 4470202S

600 ADLS1115-24-HB-XXX 1115 0.618 603 1.5 2872008C1E1 4450102 4450202S 4470202S

700 ADLS1295-24-HB-XXX 1295 0.621 709 1.5 2872104C1E1 4450102 4450202S 4470202S

800 ADLS1475-24-HB-XXX 1475 0.624 818 1.5 2872104C1E1 4450102 4450202S 4470202S

900 ADLS1655-24-HB-XXX 1655 0.626 928 1.5 2872104C1E1 4450103 4450203S 4470203S

1000 ADLS1835-24-HB-XXX 1835 0.629 1040 1.5 2872104C1E1 4450103 4450203S 4470203S

228 to 288F

Span Distance(ft)

Cable Part Number

Maximum RateCable Load

(MRCL) (lbf)

Cable OD

(inches)

Installation Load (lbf)

InstallationSag Dead End

Al Support < 600 ft

Span

Al Suspension w/o SSR (< 600 ft)

Al Suspension

with SSR

up to 450 ADLS1025-24-HB-XXX 1025 0.743 608 1.5 2872011C1E1 4450104 4450204S 4470205S

500 ADLS1155-24-HB-XXX 1155 0.745 678 1.5 2872011C1E1 4450104 4450204S 4470205S

600 ADLS1385-24-HB-XXX 1385 0.748 820 1.5 2872011C1E1 4450105 4450204S 4470205S

700 ADLS1605-24-HB-XXX 1605 0.751 965 1.5 2872107C1E1 4450105 4450205S 4470205S

800 ADLS1835-24-HB-XXX 1835 0.754 1111 1.5 2872107C1E1 4450105 4450205S 4470205S

900 ADLS2105-24-HB-XXX 2105 0.757 1262 1.5 2872107C1E1 4450105 4450205S 4470205S

1000 ADLS2325-24-HB-XXX 2325 0.760 1413 1.5 2872107C1E1 4450105 4450205S 4470205S

For longer span applications, contact Prysmian for specific cable designs

Page 87: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

87

AD

SS

500A

DS0

63 L

ON

G S

PAN

AD

SS 1

-17

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

Long Span ADSSAll-Dielectric Self-Supporting Loose Tube Cable

84 to 144F

Span Distance(ft)

Cable Part Number

Maximum RateCable Load

(MRCL) (lbf)

Cable OD

(inches)

Installation Load (lbf)

InstallationSag Dead End

Al Support < 600 ft

Span

Al Suspension w/o SSR (< 600 ft)

Al Suspension

with SSR

up to 500 ADLS1025-24-HB-XXX 1025 0.492 351 1.5 2872004C1E1 4450100 4450200S 4470200S

600 ADLS1155-24-HB-XXX 1155 0.495 425 1.5 2872004C1E1 4450100 4450200S 4470200S

700 ADLS1385-24-HB-XXX 1385 0.500 505 1.5 2872100C1E1 4450100 4450200S 4470200S

800 ADLS1565-24-HB-XXX 1565 0.503 584 1.5 2872100C1E1 4450100 4450200S 4470201S

900 ADLS1785-24-HB-XXX 1785 0.508 668 1.5 2872100C1E1 4450100 4450200S 4470201S

1000 ADLS2015-24-HB-XXX 2015 0.513 754 1.5 2872101C1E1 4450100 4450200S 4470201S

Single HDPE Jacket (without track resistance) SafeStrain Design | ADLSNESC Medium Load6-72 fibers ezSPAN ADSS design is recommended

156 to 216F

Span Distance(ft)

Cable Part Number

Maximum RateCable Load

(MRCL) (lbf)

Cable OD

(inches)

Installation Load (lbf)

InstallationSag Dead End

Al Support < 600 ft

Span

Al Suspension w/o SSR (< 600 ft)

Al Suspension

with SSR

up to 400 ADLS1025-24-HB-XXX 1025 0.616 400 1.5 2872008C1E1 4450102 4450202S 4470202S

500 ADLS1155-24-HB-XXX 1155 0.619 503 1.5 2872008C1E1 4450102 4450202S 4470202S

600 ADLS1385-24-HB-XXX 1385 0.622 611 1.5 2872008C1E1 4450102 4450202S 4470202S

700 ADLS1655-24-HB-XXX 1655 0.626 722 1.5 2872104C1E1 4450103 4450203S 4470203S

800 ADLS1875-24-HB-XXX 1875 0.630 834 1.5 2872104C1E1 4450103 4450203S 4470203S

900 ADLS2105-24-HB-XXX 2105 0.634 948 1.5 2872104C1E1 4450103 4450203S 4470203S

1000 ADLS2375-24-HB-XXX 2375 0.638 1067 1.5 2872104C1E1 4450103 4450203S 4470203S

228 to 288F

Span Distance(ft)

Cable Part Number

Maximum RateCable Load

(MRCL) (lbf)

Cable OD

(inches)

Installation Load (lbf)

InstallationSag Dead End

Al Support < 600 ft

Span

Al Suspension w/o SSR (< 600 ft)

Al Suspension

with SSR

up to 375 ADLS1025-24-HB-XXX 1025 0.743 506 1.5 2872011C1E1 4450104 4450204S 4470205S

400 ADLS1115-24-HB-XXX 1115 0.745 542 1.5 2872011C1E1 4450104 4450204S 4470205S

500 ADLS1385-24-HB-XXX 1385 0.748 684 1.5 2872011C1E1 4450105 4450204S 4470205S

600 ADLS1655-24-HB-XXX 1655 0.752 828 1.5 2872011C1E1 4450105 4450205S 4470205S

700 ADLS1925-24-HB-XXX 1925 0.755 975 1.5 2872107C1E1 4450105 4450205S 4470205S

800 ADLS2235-24-HB-XXX 2235 0.759 1127 1.5 2872107C1E1 4450105 4450205S 4470205S

900 ADLS2505-24-HB-XXX 2505 0.762 1279 1.5 2872107C1E1 4450105 4450205S 4470205S

For longer span applications, contact Prysmian for specific cable designs

Page 88: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

88

AD

SS

500A

DS0

63 L

ON

G S

PAN

AD

SS 1

-17

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

Long Span ADSSAll-Dielectric Self-Supporting Loose Tube Cable

84 to 144F

Span Distance(ft)

Cable Part Number

Maximum RateCable Load

(MRCL) (lbf)

Cable OD

(inches)

Installation Load (lbf)

InstallationSag Dead End

Al Support < 600 ft

Span

Al Suspension w/o SSR (< 600 ft)

Al Suspension

with SSR

up to 300 ADLS1025-12-HB-XXX 1025 0.492 210 1.5 2872004C1E1 4450100 4450200S 4470200S

400 ADLS1295-24-HB-XXX 1295 0.498 286 1.5 2872004C1E1 4450100 4450200S 4470200S

500 ADLS1605-24-HB-XXX 1605 0.504 266 1.5 2872004C1E1 4450100 4450200S 4470201S

600 ADLS1925-24-HB-XXX 1925 0.511 450 1.5 2872005C1E1 4450100 4450200S 4470201S

700 ADLS2285-24-HB-XXX 2285 0.518 538 1.5 2872101C1E1 4450100 4450200S 4470201S

800 ADLS2615-24-HB-XXX 2615 0.525 630 1.5 2872101C1E1 4450100 4450200S 4470201S

Single HDPE Jacket (without track resistance) SafeStrain Design | ADLSNESC Heavy Load6-72 fibers ezSPAN ADSS design is recommended

156 to 216F

Span Distance(ft)

Cable Part Number

Maximum RateCable Load

(MRCL) (lbf)

Cable OD

(inches)

Installation Load (lbf)

InstallationSag Dead End

Al Support < 600 ft

Span

Al Suspension w/o SSR (< 600 ft)

Al Suspension

with SSR

up to 200 ADLS1025-24-HB-XXX 1025 0.616 200 1.5 2872008C1E1 4450102 4450202S 4470202S

300 ADLS1115-24-HB-XXX 1115 0.618 301 1.5 2872008C1E1 4450102 4450202S 4470202S

400 ADLS1475-24-HB-XXX 1475 0.624 409 1.5 2872008C1E1 4450102 4450202S 4470202S

500 ADLS1835-24-HB-XXX 1835 0.629 520 1.5 2872008C1E1 4450103 4450203S 4470203S

600 ADLS2195-24-HB-XXX 2195 0.635 635 1.5 2872008C1E1 4450103 4450203S 4470203S

700 ADLS2555-24-HB-XXX 2555 0.641 753 1.5 2872104C1E1 4450103 4450203S 4470203S

240 to 288F

Span Distance(ft)

Cable Part Number

Maximum RateCable Load

(MRCL) (lbf)

Cable OD

(inches)

Installation Load (lbf)

InstallationSag Dead End

Al Support < 600 ft

Span

Al Suspension w/o SSR (< 600 ft)

Al Suspension

with SSR

up to 250 ADLS1025-24-HB-XXX 1025 0.743 338 1.5 2872011C1E1 4450104 4450204S 4470205S

300 ADLS1245-24-HB-XXX 1245 0.746 408 1.5 2872011C1E1 4450104 4450204S 4470205S

400 ADLS1655-24-HB-XXX 1655 0.752 552 1.5 2872011C1E1 4450105 4450205S 4470205S

500 ADLS2105-24-HB-XXX 2105 0.757 701 1.5 2872011C1E1 4450105 4450205S 4470205S

600 ADLS2505-24-HB-XXX 2505 0.762 853 1.5 2872011C1E1 4450105 4450205S 4470205S

For longer span applications, contact Prysmian for specific cable designs

Page 89: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

89

AD

SS

500A

DS0

63 L

ON

G S

PAN

AD

SS 1

-17

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

Long Span ADSSAll-Dielectric Self-Supporting Loose Tube Cable

Fiber Count Spanft (m)

NESC Heavy, 1% Sag NESC Medium, 1% Sag NESC Light, 1% Sag

Diameterinches (mm)

Weightlb/kft (kg/km)

Diameterinches (mm)

Weightlb/kft (kg/km)

Diameterinches (mm)

Weightlb/kft (kg/km)

2 - 72 200 (61) 0.53 (13.4) 97 (144) 0.52 (13.3) 95 (142) 0.52 (13.3) 95 (142)

400 (122) 0.55 (13.9) 103 (153) 0.53 (13.5) 98 (146) 0.53 (13.4) 97 (144)

600 (183) 0.57 (14.4) 109 (162) 0.55 (13.9) 103 (153) 0.54 (13.6) 99 (148)

800 (244) 0.60 (15.3) 122 (182) 0.56 (14.2) 106 (158) 0.55 (13.9) 103 (153)

1000 (305) 0.64 (16.2) 135 (201) 0.57 (14.5) 111 (165) 0.56 (14.1) 106 (157)

1200 (366) 0.67 (17.0) 147 (218) 0.60 (15.3) 122 (182) 0.57 (14.4) 110 (163)

1600 (488) 0.65 (16.5) 140 (208) 0.62 (15.7) 127 (189)

2000 (610) 0.69 (17.6) 157 (234) 0.65 (16.6) 141 (210)

84 - 144 200 (61) 0.57 (14.6) 114 (169) 0.57 (14.6) 114 (169) 0.57 (14.6) 114 (169)

400 (122) 0.59 (15.1) 120 (179) 0.58 (14.8) 116 (172) 0.58 (14.6) 114 (170)

600 (183) 0.61 (15.5) 127 (188) 0.59 (15.1) 120 (179) 0.59 (14.9) 117 (175)

800 (244) 0.65 (16.5) 141 (210) 0.60 (15.4) 124 (184) 0.60 (15.1) 121 (180)

1000 (305) 0.68 (17.3) 154 (229) 0.62 (15.8) 130 (193) 0.60 (15.4) 124 (184)

1200 (366) 0.71 (17.9) 164 (244) 0.65 (16.5) 141 (210) 0.62 (15.7) 129 (192)

1600 (488) 0.77 (19.6) 192 (286) 0.70 (17.8) 161 (240) 0.67 (16.9) 147 (219)

2000 (610) 0.74 (18.8) 179 (267) 0.71 (17.9) 164 (244)

156 - 216 200 (61) 0.70 (17.8) 157 (234) 0.70 (17.8) 156 (233) 0.70 (17.8) 156 (233)

400 (122) 0.72 (18.3) 165 (245) 0.71 (18.0) 160 (238) 0.70 (17.9) 159 (236)

600 (183) 0.75 (19.0) 178 (265) 0.72 (18.3) 166 (247) 0.72 (18.2) 163 (243)

800 (244) 0.77 (19.6) 189 (281) 0.73 (18.6) 171 (254) 0.73 (18.4) 168 (250)

1000 (305) 0.80 (20.4) 202 (301) 0.76 (19.3) 182 (272) 0.74 (18.7) 172 (255)

1200 (366) 0.83 (21.0) 215 (319) 0.78 (19.9) 193 (288) 0.76 (19.4) 184 (274)

1600 (488) 0.83 (21.0) 215 (319) 0.80 (20.4) 202 (301)

2000 (610) 0.87 (22.0) 235 (349) 0.84 (21.3) 220 (327)

240 - 288 200 (61) 0.83 (21.1) 207 (308) 0.83 (21.0) 205 (305) 0.83 (21.0) 205 (305)

400 (122) 0.85 (21.5) 216 (321) 0.84 (21.3) 211 (313) 0.83 (21.2) 209 (311)

600 (183) 0.87 (22.2) 229 (340) 0.85 (21.6) 218 (324) 0.84 (21.5) 215 (319)

800 (244) 0.90 (22.9) 244 (363) 0.87 (22.2) 229 (340) 0.86 (21.7) 220 (327)

1000 (305) 0.93 (23.5) 257 (382) 0.89 (22.6) 238 (354) 0.88 (22.3) 232 (345)

1200 (366) 0.95 (24.2) 272 (404) 0.91 (23.2) 249 (371) 0.90 (22.8) 242 (360)

1600 (488) 0.96 (24.3) 274 (408) 0.94 (23.8) 264 (393)

2000 (610) 0.97 (24.7) 284 (422)

For zero strain and rack resistant Jacket options, Contact your Prysmian representative or for information about designs with alternative span requirements

or cable diameters. Cable diameters and weights may vary depending on specific span design requirements.

Dual HDPE Jacket (without track resistance) SafeStrain™ Design | ADLD

Page 90: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

90

AD

SS

500A

DS0

63 L

ON

G S

PAN

AD

SS 1

-17

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

Ordering Guide

The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below

Example: Long Span ADSS | single jacket (24 fibers/tube with two 12 fiber binder groups) with 144 single-mode fibers (printed in feet)

F ADL S XXXX 24 HB 144 E3

LENGTH MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 5 FIBER GROUPING 6 FIBER TYPE 7 FIBER COUNT 8 FIBER GRADE

FIBER INFORMATION

6 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 C & D)

CE = Single-Mode Corning® SMF28e+

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2/B2 & G.652.D)

TU = TeraLight™ Ultra Single-Mode

LE = LEAF® NZDSF (ITU G.655)

MULTIMODE Wavelength Bandwidth 1 GbE 10 GbE (nm) (MHz) Dist (m) Dist (m)

G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___

G5 = OM2+ BIF (50μm) 850/1300 700/500 800/550 150/___

G3 = OM3 BIF (50μm) 850/1300 1500/500 1000/550 300/___

G4 = OM4 BIF (50μm) 850/1300 3500/500 1100/550 550/___

7 FIBER COUNT

002 to 288 fibers

8 FIBER GRADE

SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, or CE

E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, CE, B1, or B2

NA = 0.40/0.25 1310/1550 TeraLight™ Ultra Single-Mode

N1 = 0.25 1550 LEAF® Single-Mode

MULTIMODE Attenuation (dB/km) Wavelength (nm)

M2 = 3.5/1.0 850/1300

M3 = 3.0/1.0 850/1300

Other cable constructions and fiber performance grades available on request.

4 LOAD RATING

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

ADL = Long Span ADSS

3 CONSTRUCTION

S = Single Jacket

D = Double Jacket

T = Track Resisitant Jacket

4 LOAD RATING

Max Rated Cable Load (lbs)

5 FIBER GROUPING

12 = 12f per tube

24 = 24f per tube (12 fibers per unit)

1

Page 91: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

91

AD

SS

500A

DS0

63 L

ON

G S

PAN

AD

SS 1

-17

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

ORDERING CHECK LIST

1 Installation Location: City _____________________________ State ___________

2 Cable Length Marking ” Feet ” Meters

3 # of Jackets: ” Single Jacket ” Dual Jacket

4 Number of Fibers: ______________

5 Fiber Type & Grade: ______________

6 Max. Span Length: (ft or m) _______________

7 Installation Sag: ” 1.5% ” Other (Please Specify) _____________

8 NESC Loading Condition: ” Light ” Medium ” Heavy

” Other (Define Ice & Wind Load) __________________

9 Line Voltage: ” None ” Distribution Line

Transmission Line _____ Phase to Phase (kV)______ Phase to Ground_______

10 Fiber Strain: ” Safe Strain ” Zero Strain

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2017 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued January 2017.

Page 92: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

92

TOO

LS

500E

DSO

124

BU

FFER

TU

BE

SLIT

TER

06-

17

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

Buffer Tube SlitterHand tool for easy mid-span access to buffer tubes

Features and Benefits Precision Engineering

- No adjustment or tuning required- Depth of cut is optimized for each specific tube size- Buffer tube walls are slit open without risk of fiber damage

Rugged Construction- Body is machined from solid aluminum- Built for use in the real world

Recessed Blades- Cutting surfaces are protected- Minimal blade projection enhances tool safety

Compact and Lightweight- Easy to transport - Saves room in the toolkit

Clearly and Permanently Marked- Both halves of the tool are engraved with size information- Correct slitting direction is clearly marked- All critical information is machined directly into the tool and cannot rub off

Heavy Duty Retaining Cord- Keeps the two halves together for easier location and use

Buffer Tube Sizing Guides- Allows tube dimensions to be checked without applying the tool

Quick, Safe and Easy Mid-Span Access- Saves time, avoids injuries and protects fiber assets

Economical- Pays for itself by avoiding dangerous work practices - Just as effective and more durable than units costing many times more

Page 93: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

93

TOO

LS

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom 50

0E D

SO12

4 B

UFF

ER T

UB

E SL

ITTE

R 0

6-17

*Note: Always check the current datasheet for the cable you are using to verify the buffer tube size prior to selecting a buffer tube slitter.

Buffer Tube SlitterHand tool for easy mid-span access to buffer tubes

Spare Parts Quanity Per Tool Part Number

Blades (2) 2 9000090015

Retainer Cord 1 9000090008

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2017. All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued June 2017.

PART NUMBERS

Cable Design Fiber Count Nominal Tube OD (mm) Part Number

ActionLink™ 2 - 72 1.9 9000090000

AeroLink™ ADSS 2 - 144 2.5 9000090001

AeroLink™ fig 8 2 - 216 2.65 9000090017

AeroLink ™fig 8 2 - 216 2.5 9000090001

CampusLink™ 2 - 12 4.1 9000090003

CentraLink™ 2 - 12 4.1 9000090003

CentraLink™ CD 2 - 12 2.8 9000090014

Express™ LT 2- 288 2.5 9000090001

FirstLink™/FlexLink™ 2 - 312 2.65 9000090017

FlexLink™ Dry 2- 288 2.8 9000090014

FusionLink™ RICT 12 - 72 6.2 9000090004

FusionLink™ RICT 84 - 96 8.4 9000090005

FusionLink ™RICT 108 - 144 9.9 9000090019

FusionLink™ RICT 156 - 216 11.0 9000090006

FusionLink™ RICT 240 - 432 14.3 9000090018

FusionLink™ RICT 456 - 576 15.4 9000090038

FusionLink™ RICT Dry 12 - 48 6.2 9000090004

FusionLink™ RICT Dry 60 - 96 9.5 9000090007

FusionLink™ RICT Dry 108 - 144 10.6 9000090010

FusionLink™ RICT Dry 156 - 216 12.3 9000090012

FusionLink™ RICT Dry 240 - 288 14.3 9000090018

FusionLink™ RICT Dry 312 - 432 15.4 9000090038

FusionLink™ RICT I/O 12 - 96 8.4 9000090005

FusionLink™ RICT I/O 108 - 216 11 9000090006

LT 2.0 4 - 456 2.0 9000090039

MassLink™ Multi-Tube Ribbon 288 - 432 6.2 9000090004

MassLink™ Multi-Tube Ribbon 444 - 864 7.9 9000090009

MassLink™ Multi-Tube Ribbon 1296 - 1728 12.1 9000090040

MassLink™ Multi-Tube Ribbon I/O 216 - 432 6.2 9000090004

MiniLink™ 2 - 144 1.9 9000090000

Resilink™ ADF 1 - 12 2.8 9000090014

Page 94: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

94

TOO

LS

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | www.prysmiangroup.com Sales and Distribution: 2512 Penny Road | Claremont, NC 28610 | +1-800-879-9862 50

0E D

S122

EZ

TOO

LS B

UFF

ER T

UB

E M

IDSP

AN

ACC

ESS

TOO

L 20

17-0

9-06

Product Snapshot Applications Reliable midspan entry to access fibers in loose tube cables. Easy change inserts for a variety of manufacturers’ tube sizes. Cable Types Loose Tube, ADSS, Microduct & Specialty Tool Type One Hand Operation / Shaving Action Quick Change Inserts / Rugged Options Kit (1 tool, 3 inserts, accessories) / Inserts (10) to fit a Variety of Buffer Tube Sizes Content may be subject to change without notification

ezTOOLS™ | Buffer Tube Midspan Access ToolBuffer Tube Midspan Access Tool (1.8 to 3.0 mm)

The simplest and most reliable midspan access tool for loose buffer tubes. OverviewPrysmian’s ezACCESS | Buffer Tube Access Tool provides quick and easy access to fibers every time. Designed for midspan entry in buffer tubes to access fibers, this is the one-stop tool for the veteran or the new installer.

Specially designed inserts hold the buffer tube firmly in place where a precision-ground blade “shaves” only the tube wall - providing reliable access without damage to the fiber or coating. An industry study revealed that Prysmian’s ezACCESS Buffer Tube Access tool provides the most consistent, safe and reliable access while other tools frequently damaged fibers and / or coatings.

Interchangeable labeled inserts support a wide variety of buffer tubes sizes used for different fiber counts and cable designs. The tool’s thick guage steel alloy construction and a hard shell tote case mean years of reliable field use. These interchangeable inserts change in and out within 15 seconds.

Kit Contains- 1 Buffer Tube Access Tool with Carrying Case

- Two Kit Options: • 3 inserts (2.5mm, 2.0mm, 3.0mm – common sizes) • 3 inserts (2.5mm, 2.7mm, 3.0mm)

- Spare parts: 1 spare blade, 1 socket head screw

Features and Benefits Reliable Tube Access

- Reliable and repeatable access to fibers without damage- Lab tested & field proven- No calibration required - Rugged and built to last Simple & Flexible Support of Multiple Size Buffer Tubes

- Multi-purpose tool supports up to 10 insert sizes- 15 second change out of inserts - Cleaner midspan access

Page 95: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

95

TOO

LS

500E

DS1

22 E

ZTO

OLS

BU

FFER

TU

BE

MID

SPA

N A

CCES

S TO

OL

2017

-09-

06

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2017 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued September 2017.

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | www.prysmiangroup.com Sales and Distribution: 2512 Penny Road | Claremont, NC 28610 | +1-800-879-9862

Ordering Guide

Inserts for Draka Products

Tube Diameter mm

Fibers Per Tube Draka Cable Description

Part Number (Tool)

1.9 12 ezMICROduct™, ezDROP™ | Flat (≤ 6 fibers), ezDROP | Figure 8 20021564

*2.0 12 LT20 20022885

*2.5 12 ExpressLT™ Gel & Gel-Free 20021566

2.6 12Loose Tube | Indoor-Outdoor (> 36 fibers)

ADSS | Long Span (2 to 84 fibers)20021602

*2.7 12 ezPREP Loose Tube | Gel & Gel-Free (discontinued April 2010) 20030089

*3.0 12ExtremeLink™ Loose Tube

ezSPAN™ ADSS Loose Tube | Figure 820021569

3.0 24ADSS | Long Span (96-288 fibers, 24 fibers / tube)

Loose Tube | High Count (> 288 fibers, 24 fibers / tube)20021570

Item Description Part Number

Tool Kit Includes: 1 Buffer Tube Access Tool with carrying case 3 Inserts (2.5mm / 2.0mm / 3.0mm) Spare Parts: 1 spare blade, 1 spare socket head screw Accessories: 1 fiber spatula, 1 allen wrench

CUS10003914

Tool Kit Includes: 1 Buffer Tube Access Tool with carrying case 3 Inserts (2.5mm / 2.7mm / 3.0mm - common sizes) Spare Parts: 1 spare blade, 1 spare socket head screw Accessories: 1 fiber spatula, 1 allen wrench

20021562

Spare Parts Kit Includes: 2 blades, 2 socket head screws, 1 fiber spatula

20021563

ezTOOLS™ | Buffer Tube Midspan Access ToolBuffer Tube Midspan Access Tool (1.9 to 3.0 mm)

*Replacement inserts are also available for purchase individually.

Page 96: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

96

Flame Rated (FR) CablesPrysmian offers a wide variety of indoor and indoor/outdoor cables

Optical fiber networks usually begin

and end inside buildings or other

environmentally controlled structures

that house the network transmission

equipment. As a result, outside plant

optical cables typically transition to

indoor or indoor-outdoor optical cables

as the cables enter the building.

PRYSMIAN’S INDOOR AND INDOOR/OUTDOOR CABLES In addition to the typical optical and mechanical performance requirements, in-building cables are subject to fire and safety requirements as defined within the American National Electric Code (NEC), Canadian Standards Association’s (CSA), Canadian Electric Code (CEC), or local codes.

Such standards define cable performance requirements for flame propagation and smoke generation characteristics according to environmental conditions of a cable’s installed location. In-building cables are tested to these standards in qualified laboratories and “listed” according to their flame and smoke performance characteristics. Indoor and indoor/outdoor cables must be labeled (printed) with the appropriate listing information. Prysmian flame retardant cables are typically printed with both NEC and CSA designations.

FLAME/SMOKE RATINGS

The NEC flame requirements are divided into three separate rating categories: Plenum, Riser, and General Purpose. These categories are defined as follows:

1. Plenum: These cables are used within buildings in ducts, plenums, or other spaces used for environmental (HVAC) air distribution. Cables located in the air handling spaces should either meet the plenum standard or they must be installed in metal conduits. The required plenum performance test – NFPA 262 (formerly UL 910) – measures both flame propagation and smoke generation in a high intensity flame and constant air flow environment. FT-6 is the equivalent Canadian test procedure. A plenum rating is the most stringent of all flame retardant listings.

2. Riser: These cables transition between floors and are typically installed in vertical building shafts. Cables installed between floors must either have plenum or riser listings or be placed in metal conduits. The riser rated cables must meet the UL 1666 performance test requirements. An equivalent Canadian test to the UL 1666 riser test does not exist. Riser Rating is less stringent than the Plenum Rating.

3. General Purpose (Vertical Tray): General purpose cables are installed in non-plenum or non-riser applications and are intended for general use within buildings. These cables are typically used in non-plenum horizontal applications. UL 1581-1160 is the requisite NEC flame performance standard and FT-4 is the requisite Canadian standard. Due to their superior flame characteristics, riser and plenum cables can also be used for general purpose deployments.

NEC Cable Fire Test Hierarchy

OFNG OFN OFCG OFCGeneralPurpose

OFNR OFCRRiser

Plenum

NONCONDUCTIVE CONDUCTIVE

OFNP OFCP

A B Cable A may be used in place of cable B

FLA

ME

RA

TED

Page 97: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

97

Due to concerns with smoke generation during cable combustion, North American cable standards have evolved to include reduced smoke generation requirements. Cables that achieve the smoke density requirements of UL 1685 obtain an OFN-LS (optical fiber non-conductive with low smoke) or OFC-LS listing. Cables that pass the smoke generation specifications from UL 1685 along with the flame spread requirements of UL 1666 receive an OFNR-LS listing.

Also, due to the harmful effects of halogenated smoke on humans and electronic equipment, interest in cables made with non-halogen materials continues to grow. Most low smoke rated cables are also manufactured using zero halogen materials giving rise to the term LSZH (Low Smoke Zero Halogen).

UL 1685Limited Smoke

CSA FT4-ST1Limited Smoke

CSA FT1No Smoke Requirements

UL 1581-1080/VW1No Smoke Requirements

UL 1666No Smoke Requirements

NFPA 262 (CSA FT-6) Low Smoke

NEC Cable Smoke Test Hierarchy

The NEC label terminology for various cable listings designations is shown in Table 1. These designations are often used as “shorthand” for identifying the cable types according to their flame and smoke listings.

NEC Rating Description

OFNP (CSA FT-6) Non-conductive optical fiber plenum cable

OFCP (CSA FT-6) Conductive optical fiber plenum cable

OFNR Non-conductive optical fiber riser cable

OFCR Conductive optical fiber riser cable

OFNG (CSA FT-4) Non-conductive optical fiber general purpose cable

OFCG (CSA FT-4) Conductive optical fiber general purpose cable

OFN Non-conductive optical fiber general purpose cable

OFC Conductive optical fiber general purpose cable

Table 1

INDUSTRY STANDARDS In addition to adhering to the flame & smoke standards, Prysmian’s indoor and indoor/outdoor flame retardant cables also comply with the various national and international standards that define optical cable performance. These standards are as follows:

- TIA/EIA-568: Commercial Building Telecommunications Cabling Standard - TIA/EIA-598: Optical Fiber Cable Color Coding - ANSI/ICEA S-83-596: Standard for Indoor Optical Fiber Cable - ANSI/ICEA S-87-640: Standard for Optical Fiber Outside Plant Communications Cable - ANSI/ICEA S-104-696: Standard for Optical Fiber indoor/OutOutdoor Fiber Cable - Telcordia GR-409-CORE: Generic Requirements for Indoor Fiber Optic Cable - Telcordia GR-20-CORE: Generic Requirements for Optical Fiber and Optical Fiber Cable

FLAM

E RA

TED

Page 98: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

98

ORDERING GUIDE - INDOOR

F 400 AJ 00 HB 012 EB

2 PRODUCT FAMILY 3 CONSTRUCTION 4 FIBER

GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADELENGTH MARKINGS1

Other cable constructions and fiber performance grades available.

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

PART NUMBER CONTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

REFER to INDOOR PRODUCT TABLE

3 CONTRUCTION

INTERLOCK ARMOR (optional)

(blank) = none

AJ = Jacketed Aluminum

SJ = Jacketed Steel

4 FIBER GROUPING

00 = no grouping

01 = 1f per unit or tube

06 = 6f per unit or tube

08 = 8f per unit or tube

12 = 12f per unit or tube or ribbon

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 D)

CE = Corning™ Single-Mode (ITU G.652 D Compliant)

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

MULTIMODEWavelength

(mm)Bandwidth

(MHz)1 GbE

Dist (m)10 GbE

Dist (m)

G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___

G5 = OM2+ BIF (50μm) 850/1300 700/500 800/550 150/___

G3 = OM3 BIF (50μm) 850/1300 1500/500 1000/550 300/___

G4 = OM4 BIF (50μm) 850/1300 3500/500 1100/550 550/___

6 FIBER COUNT

002 TO 216 fibers

7 FIBER GRADE

SINGLE-MODE | Tight Buffer (TB) MULTIMODE

Attenuation (dB/km) Wavelength (nm) Fiber Type Attenuation (dB/km) Wavelength (nm) Type

EA = 0.50/0.50/0.50 1310/1383/1550 HB, ES, CE, B1, or B2 M1 = 3.5/1.5 850/1300 OM2+, OM3, OM4

EB = 0.70/0.70/0.70 1310/1383/1550 HB, ES, CE, B1, or B2 M2 = 3.5/1.0 850/1300 OM1

E7 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, CE, B1, or B2 M3 = 3.0/1.0 850/1300 OM2+, OM3, OM4

SINGLE-MODE | Ribbon & Loose Fiber

Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, CE, B1, or B2

E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, CE, B1, or B2

The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance.The appropriate part number can be configured using the process described below:

Example: ezDISTRIBUTION, tight buffer, interlock armor riser rated with 12 single-mode fibers 0.70/0.70/0.70 dB/Km @ 1310/1383/1550.

FLA

ME

RA

TED

Page 99: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

99

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2018 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued May 2018.

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

2 PRODUCT FAMILY

900 MICRON TIGHT BUFFER InterLock Flame Rating

ezINTERCONNECT™900 = 1f 900 Micron Diameter - PVC N N/A

900F = 1f 900 Micron Diameter - PVDF N N/A

900H = 1f 900 Micron Diameter - Polyester Elastomer N N/A

900Z = 1f 900 Micron Diameter - LSZH N N/A

ezINTERCONNECT™ Simplex and Duplex516 = 1f ezINTERCONNECT™ Riser Simplex (1.6mm) N/A OFNR/FT4

520 = 1f ezINTERCONNECT™ Riser Simplex (2.0mm) N/A OFNR/FT4

529 = 1f ezINTERCONNECT™ Riser Simplex (2.9mm) N/A OFNR/FT4

516Z = 2f ezINTERCONNECT™ Riser Zipcord (1.6mm) N/A OFNR/FT4

520Z = 2f ezINTERCONNECT™ Riser Zipcord (2.0mm) N/A OFNR/FT4

529Z = 2f ezINTERCONNECT™ Riser Zipcord (2.9mm) N/A OFNR/FT4

529R = 2f ezINTERCONNECT™ Riser Round (2.9mm) N/A OFNR/FT4

548R = 2 to 4f ezINTERCONNECT™ Riser Round (1.6mm) N/A OFNR/FT4

816 = 1f ezINTERCONNECT™ Plenum Simplex (1.6mm) N/A OFNP/FT6

820 = 1f ezINTERCONNECT™ Plenum Simplex (2.0mm) N/A OFNP/FT6

829 = 1f ezINTERCONNECT™ Plenum Simplex (2.9mm) N/A OFNP/FT6

816Z = 2f ezINTERCONNECT™ Plenum Zipcord (1.6mm) N/A OFNP/FT6

820Z = 2f ezINTERCONNECT™ Plenum Zipcord (2.0mm) N/A OFNP/FT6

829Z = 2f ezINTERCONNECT™ Plenum Zipcord (2.9mm) N/A OFNP/FT6

829R = 2f ezINTERCONNECT™ Plenum Round (2.9mm) N/A OFNP/FT6

848R = 2 to 4f ezINTERCONNECT™ Plenum Round (4.8mm) N/A OFNP/FT6

LSZH16 = 1f ezINTERCONNECT™ LSZH Riser Simplex (1.6mm) N/A OFNR/FT4

LSZH20 = 1f ezINTERCONNECT™ LSZH Riser Simplex (2.0mm) N/A OFNR/FT4

LSZH29 = 1f ezINTERCONNECT™ LSZH Riser Simplex (2.9mm) N/A OFNR/FT4

LSZH16Z = 2f ezINTERCONNECT™ LSZH Riser Zipcord (1.6mm) N/A OFNR/FT4

LSZH20Z = 2f ezINTERCONNECT™ LSZH Riser Zipcord (2.0mm) N/A OFNR/FT4

LSZH29Z = 2f ezINTERCONNECT™ LSZH Riser Zipcord (2.9mm) N/A OFNR/FT4

LSZH20R = 2f ezINTERCONNECT™ LSZH Riser Round (2.9mm) N/A OFNR/FT4

ezDISTRIBUTION™400 = 2 to 144f ezDISTRIBUTION™ Riser Y OFNR/FT4

800 = 2 to 144f ezDISTRIBUTION™ Plenum Y OFNP/FT6

600 = 2 to 144f ezDISTRIBUTION™ Riser LSZH N OFNR-LS/FT4

ezBREAKOUT™516 = 2 to 12f ezBREAKOUT XS™ Riser (1.6mm subunits) N OFNR/FT4

525 = 2 to 24f ezBREAKOUT™ Riser (2.5mm subunits) Y OFNR/FT4

825 = 2 to 24f ezBREAKOUT™ Plenum (2.5mm subunits) Y OFNP/FT6

LSZH25 = 2 to 24f ezBREAKOUT™ Riser (2.5mm subunits) Y OFNR/FT4

RIBBON PRODUCTS InterLock Flame Rating

ezRibbon™ & COLink™ RibbonFRP = 12f ezRIBBON™ Interconnect Ribbon N OFNP/FT6

RRCDK = 12 to 432f COLink™ RCLT Riser Ribbon Distribution Y OFNR/FT4

RPCDK = 12 to 144f COLink™ RCLT Plenum Ribbon Distribution N OFNP/FT6

RRLDK = 144 to 576f COLink™ Multi-Tube Ribbon Riser Distribution N OFNR/FT4

RIBBON PRODUCTS InterLock Flame Rating

Micro Fiber (MFC)MFC14 = 12 to 48f 1.4mm unit MFC Plenum Micro Fiber Round N OFNP/FT6

MFCL14 = 12 to 48f 1.4mm unit MFC Riser-LSZH Micro Fiber Round N OFNR/FT4

MFC20 = 8 to 216f 2mm unit MFC Plenum Micro Fiber Round N OFNP/FT6

MFC30 = 16 to 24f 3mm MFC Plenum Micro Fiber round N OFNP/FT6

MFC = 8 to 72f 3mm unit MFC Plenum Micro Fiber Round Y OFNP/FT6

MFCL = 8 to 24f 3mm unit MFC Riser-LSZH Micro Fiber Round N OFNR/FT4

MFCZ = 16 to 24f 3mm unit MFC Plenum Zipcord Micro Fiber Round N OFNP/FT6

MFC36 = 16 to 24f 3.6mm MFC Plenum Micro Fiber Round N OFNP/FT6

MFCL36 = 16 to 24f 3.6mm MFC Riser-LSZH Micro Fiber Round N OFNR/FT4

Note: See the data sheet since a different part number configuration is used.

FLAM

E RA

TED

Page 100: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

100

ORDERING GUIDE - INDOOR/OUTDOOR

F DRLDB AJ 12 HB 072 E1

2 PRODUCT FAMILY 3 CONSTRUCTION 4 FIBER

GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADELENGTH MARKINGS1

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

PART NUMBER CONTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

REFER to INDOOR/OUTDOOR PRODUCT TABLE

3 CONTRUCTION

INTERLOCK ARMOR (optional)

(blank) = none

AJ = Jacketed Aluminum

SJ = Jacketed Steel

AB = Bare Aluminum

SB = Bare Steel

4 FIBER GROUPING

00 = no grouping | Central LT

06 = 6f per unit or tube

12 = 12f per unit or tube or ribbon

24 = 24f per ribbon

36 = 36f per ribbon

MX = Multi-Fiber ribbons

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE (LT)

Wavelength: 1310/1383/1150 nm | Attenuation: 0.4/0.4/0.3 dB/km

HB = Single-Mode (ITU G.652 D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 D)

CE = Corning™ Single-Mode (ITU G.652 D Compliant)

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

MULTIMODE (LT)Wavelength

(mm)Bandwidth

(MHz)1 GbE

Dist (m)10 GbE

Dist (m)

G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___

G5 = OM2+ BIF (50μm) 850/1300 700/500 800/550 150/___

G3 = OM3 BIF (50μm) 850/1300 1500/500 1000/550 300/___

G4 = OM4 BIF (50μm) 850/1300 3500/500 1100/550 550/___

6 FIBER COUNT

002 TO 432 fibers

7 FIBER GRADE

SINGLE-MODE | Loose Tube (LT) MULTIMODE

Attenuation (dB/km) Wavelength (nm) Fiber Type Attenuation (dB/km) Wavelength (nm) Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, CE, B1, or B2 M1 = 3.5/1.5 850/1300 OM2+, OM3, OM4

E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, CE, B1, or B2 M2 = 3.5/1.0 850/1300 OM1

M3 = 3.0/1.0 850/1300 OM2+, OM3, OM4

The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance.The appropriate part number can be configured using the process described below:

Example: CampusLink™ with InterLock™ armor, riser rated (12 fibers/tube) with 72 single-mode fibers with 0.40/0.40/0.30 (printed in feet)

FLA

ME

RA

TED

Page 101: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

101

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2017 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued July 2017.

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

2 PRODUCT FAMILY

LOOSE TUBE InterLock Flame Rating

Stranded - Riser - Gel-filled Tubes

DRLTB = 2 to 144f CampusLink LT™ I/O Riser, All-Dieletric , 1 Jacket Y OFNR/FT4

DRLTC = 2 to 144f CampusLink LT™ I/O Riser, All-Dieletric, 2 Jackets N OFNR/FT4

DRLTD = 2 to 144f CampusLink LT™ I/O Riser, Armored ,2 Jackets N OFNR/FT4

Stranded - Riser - Dry (Gel-free)

DRLDB = 2 to 288f CampusLink LT™ I/O Riser, All-Dieletric, 1 Jacket Y OFNR/FT4

DRLDC = 2 to 144f CampusLink LT™ I/O Riser, All-Dieletric, 2 Jackets N OFNR/FT4

DRLDD = 2 to 144f CampusLink LT™ I/O Riser, Armored, 2 Jackets N OFNR/FT4

Stranded - Plenum - Dry (Gel-free)

DPLDB = 2 to 144f CampusLink LT™ I/O Plenum, 1 Jacket Y OFNP/FT6

Central Loose Tube - Riser & Plenum - Dry (Gel-free)

DRLDB = 2 to 12f CampusLink LT™ I/O Riser, All-Dieletric, 1 Jacket Y OFNR/FT4

DDLSZHB = 2 to 12f CampusLink LT™ LSZH Riser, All-Dieletric, 1 Jacket Y OFNG-LS/FT4

DPLDB = 2 to 12f CampusLink LT™ I/O Plenum, 1 Jacket Y OFNP/FT6

RIBBON InterLock Flame Rating

RRIOCDK = 12 to 432f FusionLINK™ I/O Riser, Central LT (dry) N OFNR/FT4

RRCTK = 12 to 216f FusionLINK™ I/O Riser, Central LT (gel) N OFNR/FT4

RRCTK = 576 to 864f FusionLINK™ 864 I/O Riser, Central LT (gel) N OFNR/FT4

RRLTK = 288 to 432f MassLINK™ I/O Riser, Multi-Tube Ribbon N OFNR/FT4

RRIOLDK = 864 to 1728f MassLINK™ I/O 1728 Multi-Tube Ribbon (dry) N OFNR/FT4

RZLTK = 216 to 432f MassLINK™ I/O LSZH, Multi-Tube Ribbon N OFN

TIGHT BUFFER InterLock Flame Rating

C1181 = 2 to 144f ezDISTIBUTION™ I/O Riser Y OFNR/FT4

C1182 = 2 to 96f ezDISTIBUTION™ I/O Plenum Y OFNP/FT6

700 = 2 to 24f ezDISTIBUTION™ I/O LSZH Riser N OFNG-LS/FT4

Note: See the data sheet since a different part number configuration is used.

FLAM

E RA

TED

Page 102: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

102

ORDERING GUIDE - SPECIALTY

F DLSZHB AJ 12 HB 072 E1

2 PRODUCT FAMILY 3 CONSTRUCTION 4 FIBER

GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADELENGTH MARKINGS1

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

PART NUMBER CONTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

REFER to SPECIALTY PRODUCTS TABLE

3 CONTRUCTION

INTERLOCK ARMOR (optional)

(blank) = none

AJ = Jacketed Aluminum

SJ = Jacketed Steel

AB = Bare Aluminum

SB = Bare Steel

4 FIBER GROUPING

00 = no grouping | Central LT

06 = 6f per unit or tube

12 = 12f per unit or tube

FIBER INFORMATION

5 FIBER TYPE (LT) LOOSE TUBE

SINGLE-MODE (LT)

Wavelength: 1310/1383/1150 nm | Attenuation: 0.4/0.4/0.3 dB/km

HB = Single-Mode (ITU G.652 D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 D)

CE = Corning™ Single-Mode (ITU G.652 D Compliant)

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

BX = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

MULTIMODEWavelength

(mm)Bandwidth

(MHz)1 GbE

Dist (m)10 GbE

Dist (m)

G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___

G5 = OM2+ BIF (50μm) 850/1300 700/500 800/550 150/___

G3 = OM3 BIF (50μm) 850/1300 1500/500 1000/550 300/___

G4 = OM4 BIF (50μm) 850/1300 3500/500 1100/550 550/___

6 FIBER COUNT

002 TO 288 fibers

7 FIBER GRADE

SINGLE-MODE | Tight Buffer (TB) MULTIMODE

Attenuation (dB/km) Wavelength (nm) Fiber Type Attenuation (dB/km) Wavelength (nm) Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, CE, B1, B2, or BX M2 = 3.5/1.0 dB/km 850/1300 OM1 (62.5μm)

SINGLE-MODE | Tight Buffer (TB) M3 = 3.0/1.0 dB/km 850/1300 OM2+, OM3, OM4 (50μm)

Attenuation (dB/km) Wavelength (nm) Fiber TypeOther cable constructions and fiber performance grades available.

EB = 0.70/0.70/0.70 1310/1383/1550 HB, ES, CE, B1, B2, or BX

The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance.The appropriate part number can be configured using the process described below:

Example: EzLink LSZH, interlock armor (12 fibers/tube) with 72 single-mode fibers 0.40/0.40/0.30 dB/km @ 1310/1383/1550.

FLA

ME

RA

TED

Page 103: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

103

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2017 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued July 2017.

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

2 PRODUCT FAMILY

LOOSE TUBE InterLock Flame Rating

Stranded - Low-Smoke / Zero Halogen LSZH - Gel-filled Tubes - LT

DLSZHB = 2 to 216f ezLink™ Transit LSZH I/O Riser, 1 Jacket Y OFN-LS

DLSZHC = 2 to 216f ezLink™ Transit LSZH, All-Dieletric, 2 Jackets N OFN-LS

DLSZDE = 2 to 216f ezLink™ Transit LSZH, Armored, 1 Jacket N OFC-LS

Stranded - Low-Smoke / Zero Halogen LSZH - Dry (Gel-free) - LT

DDLSZHB = 2 to 288f ezLink™ Transit LSZH, All-Dieletric, 1 Jacket Y OFNR-LS/FT4

DDLSZHC = 2 to 288f ezLink™ Transit LSZH, All-Dieletric, 2 Jackets N OFNR-LS/FT4

DDLSZHE = 2 to 288f ezLink™ Transit LSZH, Armored, 1 Jacket N OFNR-LA/FT4

Airguard Harsh Environment / Petro Chemical / Tray - LT

XPLTM = 2 to 288f Oil & Gas, Harsh, Low Temp Cable, Tray, 2 Jackets N OFNG-LS/FT4 ST1

XPRLTMB = 2 to 216f I/O Harsh,1 Jackets N OFN

XPRLTMD = 2 to 216f I/O Harsh, Armored, 2 Jackets N OFC

Mining

RLTM = 2 to 144f MINEnet. I/O Riser, 2 Jacket N OFNR/FT4

Industrial / Tray - LT

IRZHB = 2 to 288f ezLink™ Indust. Riser, All-Dieletric, Tray, 1 Jacket Y OFNR-LS/FT4

IRZHC = 2 to 288f ezLink™ Indust. Riser, All-Dieletric, Tray, 2 Jackets N OFNR-LS/FT4

IRZHD = 2 to 288f ezLink™ Indust. Riser, Tray, Armored, 2 Jackets N OFNR-LS/FT4

Heavy Duty - Harsh Environment / Tray - LT

IRZHF = 2 to 288f ezLink™ Oil & Gas, HD, All-Dieletric, Tray, 1 Jacket N OFNR-LS/FT4 ST1

Airport Cable (FAA) - LT

FAACF = 2 to 60f ezLink™ Loose Tube, All-Dieletric, 2 Jackets N N/A

Multi-Dwelling Unit (MDU) - TB

MDU829 = 1f ezINTERCONNECT™ Indoor 2.9mm Dropd N OFNR/FT4

MDU548 = 1f ezINTERCONNECT™ Indoor, 4.8mm Drop N OFNR/FT4

MDU548BK = 1f ezINTERCONNECT™ I/O 4.8mm Drop N OFNR/FT4

Note: See the data sheet since a different part number configuration is used.

FLAM

E RA

TED

Page 104: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

104

AD

DIT

ION

AL

RES

OU

RCE

S

FIBER CODE ADDENDUMADDITIONAL FIBER CODES FOR USE WHEN ORDERING PRYSMIAN CABLES

The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance.The appropriate part number can be configured using the process described below:

F EDH 1A1J 12 ES 072 E3

2 PRODUCT FAMILY 3 CONSTRUCTION 4 FIBER

GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADELENGTH MARKINGS1

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 +1-800-879-9862 | +1-800-669-0808 | website: na.prysmiangroup.com/telecom

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 C & D)

CE = Single-Mode Corning™ SMF28e+

SC = Single-Mode (ITU G.652 C & D)

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & G.652.D)

B3 = Bend-Insensitive Single-Mode (ITU G.657.B3 & G.652.D)

BB = BendBright™ Single-Mode (ITU G.657.A1 & G.652.D)

CU = Corning™ Ultra Single-Mode (ITU G.657.A1 & G.652.D)

BX = BendBrightXS™ Single-Mode (ITU G.657.A2 & .B2 & G.652.D)

BE = BendBright™ Elite Single-Mode (ITU G.657.B3 & G.652.D)

CY = ClearCurve® LBL (ITU G.657.A2 & G.652.D)

CZ = ClearCurve® ZBL (ITU G.657.B3 & G.652.D)

TU = TeraLight™ Ultra Single-Mode (ITU G.655 & G.656)

LE = LEAF NZDSF (ITU.G655)

MULTIMODEWavelength

(mm)Bandwidth

(MHz)1 GbE

Dist (m)10 GbE

Dist (m)

G6 = OM1 (62.5μm) 850/1300 200/500 300/500 ---/---

C1 = OM1 Infincore (62.5μm) 850/1300 200/500 300/500 ---/---

6S = OM1 Draka (62.5μm) 850/1300 200/500 300/550 33/---

G5 = OM2 (50μm) BIF 850/1300 700/500 750/--- 150/---

G3= OM3 (50μm) BIF 850/1300 1500/500 1000/--- 300/---

G4 = OM4 (50μm) BIF 850/1300 3500/500 1100/--- 550/---

C2 = OM2 ClearCurve™ (50μm) 850/1300 700/500 750/--- 150/---

C3 = OM3 ClearCurve™ (50μm) 850/1300 1500/500 1000/--- 300/---

C4 = OM4 ClearCurve™ (50μm) 850/1300 3500/500 1100/--- 550/---

5E = MaxCap-BB-OM2+ (50μm) 850/1300 700/500 800/550 150/---

5F = MaxCap-BB-OM3 (50μm) 850/1300 1500/500 1000/550 300/---

5G = MaxCap-BB-OM4 (50μm) 850/1300 3500/500 1100/550 550/---

7 FIBER GRADE

SINGLE-MODE

Attenuation (dB/km) Wavelength (nm) Fiber Type

E1 = 0.40/0.40/0.30 1310/1383/1550 All but TU & LE

E3 = 0.35/0.35/0.25 1310/1383/1550 All but TU & LE

NA = 0.40/0.25 1310/1550 TU

N1 = 0.25 1550 TU or LE

EB = 0.7/0.7/0.7 for tight buffer products 1310/1383/1550 All but TU & LE

EA = 0.5/0.5/0.5 for tight buffer products or IC ribbon

1310/1383/1550 All but TU & LE

E7 = 0.4/0.4/0.3 for tight buffer products 1310/1383/1550 B2, BX, CY, B3, BE,

or CZ

SINGLE-MODE

Attenuation (dB/km) Wavelength (nm) Fiber Type

M2 = 3.5/1.0 850/1300 2.5μm

M3 = 3.0/1.0 850/1300 62.5μm or all 50μm

* 1383 nm attenuation specified as un-cabled fiber post hydrogen aging.

Example: ExpressLT™ Dry (gel-free) | single armor single jacket (12 fibers/tube) with 72 ESMF single-mode fibers (printed in feet)

© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2017 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued July 2017.

Page 105: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

105

AD

DITIO

NA

L RESO

UR

CES

5b: Select the jacket (sheath) configuration for this cable. (Select One)

£ Dielectric (non-armor)

£ All-Dielectric Armor

£ Single Armor – Single Jacket

£ Single Armor- Double Jacket

£ Double Armor – Triple Jacket

£ Double Jacket – Aramid Yarns between Jackets

£ Double Jacket – Fiber Glass Yarns between Jackets

£ Double Jacket – Small Rodent Resistance

- INDOOR CABLES -6a: Select the safety flame rating or special performance desired

for this cable. (Select One)

£ General Purpose

£ Riser Rated (FT4)

£ Plenum Rated (FT6)

£ Low-Smoke Zero-Halogen

£ Chemical Resistant

£ Mining Rated (MSHA)

6b: Select the cable construction you desire for this cable. (Select One)

£ Simplex (1 fiber only)

£ MDU (1 fiber only)

£ Zipcord (2 fibers only)

£ Tight Buffered Distribution

£ Tight Buffered Breakout

£ Flat Ribbon Interconnect (12 fibers only)

£ Round Central Tube Ribbon Riser

£ Data Center (12 to 72 fibers) Micro Fiber

6c: Do you desire the cable to be placed inside of interlock armor? (Select One)

£ Aluminum £ Steel £ None

- INDOOR/OUTDOOR CABLES - 7a: Select the format of the fibers for this cable.(Select One)

£ Loose Tube with Gel Tubes

£ Loose Tube with Dry Tubes

£ Tight Buffered

7b: Select the safety flame rating or special performance desired for this cable.

(Select One)

£ Riser Rated (FT4)

£ Plenum Rated (FT6)

£ Low-Smoke Zero-Halogen

- TOOLS -8: Do you need tools to help install, open or splice your fiber cable? (select one)

£ Loose Tube Tool £ Central Tube Ribbon Tool

£ Jacket Sheath Cutting Tool

1. How many fibers are needed in this cable? Choose 1-864: ____________Advice: When above 12 fibers, order in units divisible by 12 (ex: 24, 36, 48)

What type of fiber is required in this cable?(Select One)

£ Low Water Peak Single-Mode G. 652.D

£ Bend-Insensitive Fiber G.657.A1 & G.652.D

£ Bend-Insensitive Fiber, G.657.B2 & A2, G.652.D

£ Bend-Insensitive Fiber, G.657.B3 & A2, G.652.D

£ Non-Zero Dispersion Shifted Single-Mode – Large area – (NZDS-LA), G.655

£ Non-Zero Dispersion Shifted Single-Mode – TeraLight – (NZDS-TLU), G.655 & G.656

£ 62.5 micron OM1 Multimode Fiber

£ 50 micron OM2 Multimode Fiber (OM2+)

£ 50 micron OM3 10 GbE Multimode Fiber (OM3)

£ 50 micron OM4 10/40 GbE Multimode Fiber (OM4)

£ Ultra Low Loss (Long Distance)

3. Total length of cable needed? ______________ meters or feet

Advice: Prysmian has a minimum order quantity of 1,640 feet for indoor cable and 3,280 feet for outdoor cable.

4. Do you need the cable cut into specific lengths or packaged in a unique way?

Please explain:__________________________________________________Advice: Prysmian typically places cables on non-returnable wood reels.

Advice: Cables cut to lengths less than 3,280 feet (outdoor cable) or 1,640 feet (indoor cable) will require a cutting fee.

5. Is this cable for indoor, outdoor or indoor-outdoor use?(Select One)

£ For Outdoor Cables (answer questions 5A – 5B)

£ For Indoor Cables (answer questions 6A – 6C)

£ For Indoor / Outdoor Cables (answer questions 7A – 7B)

- OUTDOOR CABLES -5a: Select the cable construction you desire for this cable.(Select One)

£ Loose Tube with Gel Tubes

£ Loose Tube with Dry Tubes

£ Central Tube Ribbon with Gel-Filled Tubes (12 to 864 fibers)

£ Central Tube Ribbon with Dry Tubes (12 to 432 fibers)

£ Ribbon in Loose Tube (>288 to 864 fibers)

£ ADSS (All Dielectric Self-Support Cable)

£ Figure-8 Cable

£ Central Tube Cable (1-12 fibers only) 600 lb. strength

£ Gel Tubes £ Dry Tubes

£ Central Tube Cable (1-12 fibers only) Gel-filled 300

£ with ripcord £ without ripcord £ Gel Tubes £ Dry Tubes

£ Flat Drop Cable Dielectric (1–12 fibers only)

£ Flat Drop Cable Toneable (1-12 fibers only)

£ Hybrid Fiber & Copper

Fiber Optic Cable Pre-Ordering GuidePrysmian Group manufactures more than 100,000 varieties of fiber optic cable. We have prepared this guide to help you select the ideal cable for your application.

Page 106: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

106

AD

DIT

ION

AL

RES

OU

RCE

S

General InformationPrysmian uses the US industry standard repeating 12-color sequence. When cables go beyond 12 units, the colors repeat but use a stripe to distinguish units. Individual tubes containing 24 fibers may have a blue and orange colored binder thread separating the two 12 fiber groups.

1 2 3 4 5 6 7 8 9 10 11 12

Blue Orange Green Brown Slate White Red Black Yellow Violet Rose Aqua

Color Code Guide For Fiber Optic Specifications

Unit Position Color Code for Loose Tube (TIA-598)

PositionBuffer Tube

ColorPosition Buffer Tube Color Position Buffer Tube Color

1 Blue 13 Blue/Black Stripe 25 Blue/Red Stripe

2 Orange 14 Orange/Black Stripe 26 Orange/Red Stripe

3 Green 15 Green/Black Stripe 27 Green/Red Stripe

4 Brown 16 Brown/Black Stripe 28 Brown/Red Stripe

5 Slate (Gray) 17 Slate/Black Stripe 29 Slate/Red Stripe

6 White 18 White/Black Stripe 30 White/Red Stripe

7 Red 19 Red/Black Stripe 31 Red/Yellow Stripe

8 Black 20 Black/Black Stripe 32 Black/Red Stripe

9 Yellow 21 Yellow/Black Stripe 33 Yellow/Red Stripe

10 Violet 22 Violet/Black Stripe 34 Violet/Red Stripe

11 Rose (Pink) 23 Rose/Black Stripe 35 Rose/Red Stripe

12 Aqua 24 Aqua/Black Stripe 36 Aqua/Red Stripe

37 Blue/Green Stripe

38 Orange/Green Stripe

Page 107: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

107

AD

DITIO

NA

L RESO

UR

CES

Premise Jacket Color Code Guide

OM3/OM4Interconect Series, Riser, Plenum and LSZH

MMF - 62.5/50µm, OM1/0M2+Interconect Series,Riser, Plenum and LSZH

Single-Mode including Bend-Insenstive FiberInterconect Series, Riser, Plenum and LSZH

HybridIndoor/Outdoor Cables and Outside Plant Cable All Fiber Types

Fiber Optic Color Code for Jackets (TIA-598)

Fiber Specifications

Fiber Class Fiber Type1 GbE

Max. Distance 850nm / 1300nm

10 GbE Max. Distance

850nm / 1300nm

Bandwidth MHz-hm (OFL)

850nm / 1300nm

Indoor CableJacket Color

62.5 µm 200/500 MHz.km OM1 275m/550m 36m/300m 200/500

50 µm 700/500 MHz.km OM2 550m/550m 82m/300m 1500/500

50 µm 300 OM3 1000m/550m 300m/300m 1500/500

50 µm 550 OM4 1100m/550m 550m/300m 3500/500

Single-Mode OS1 & OS2 5-40km @ 1310nm 10km @ 1310nm40km @ 1550nm N/A

Bend-Insensitive Single-Mode Fiber

OS2 5-40km @ 1310nm 10km @ 1310nm40km @ 1550nm

N/A

Page 108: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

108

AD

DIT

ION

AL

RES

OU

RCE

S

ExpressLT™ Cable Designs

Fiber CountNumber

of Tubes/Fillers

Number of

Tube Layers

Number of Tube/Fillers

in Each Layer

Fiber Position For

Each Layer

Typical Fiber Overlength

Factor

2 to 60 5 1 5 2 to 60 1.018

62 to 72 6 1 6 62 to 72 1.028

74 to 96 8 1 8 74 to 96 1.024

98 to 120 10 1 10 98 to 120 1.030

122 to 144 12 1 12 122 to 144 1.038

146 to 216 18 26 1 to 72 1.028

12 73 to 216 1.038

228 to 264 22 28 1 to 96 1.024

14 97 to 264 1.045

276 to 288 24 29 1 to 108 1.030

15 109 to 288 1.049

300 to 360 30 212 1 to 144 1.038

18 145 to 360 1.043

372 to 432 36 3

6 1 to 72 1.028

12 73 to 216 1.038

18 217 to 432 1.043

Excess Fiber Lengths for OTDR Setup

Page 109: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

109

AD

DITIO

NA

L RESO

UR

CES

Excess Fiber Lengths for OTDR Setup

LT 2.0 Cable Designs

Fiber CountNumber

of Tubes/Fillers

Number of

Tube Layers

Number of Tube/Fillers

in Each Layer

Fiber Position For

Each Layer

Typical Fiber Overlength

Factor

2 to 60 5 1 5 2 to 60 1.024

62 to 72 6 1 6 62 to 72 1.025

74 to 96 8 1 8 74 to 96 1.025

98 to 120 10 1 10 98 to 120 1.026

122 to 144 12 1 12 122 to 144 1.033

146 to 216 18 26 1 to 72 1.024

12 73 to 216 1.033

228 to 264 22 28 1 to 96 1.025

14 97 to 264 1.045

276 to 288 24 29 1 to 108 1.042

15 109 to 288 1.061

300 to 372 30 213 1 to 156 1.050

18 157 to 372 1.070

384 to 456 36 3

7 1 to 84 1.031

13 85 to 240 1.050

18 241 to 456 1.070

Page 110: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

110

AD

DIT

ION

AL

RES

OU

RCE

S

Wooden Reel Length (feet)

Flange (in) 29.5 PLY 38 48 59 72 78 85 96 96

Traverse (in) 18 27 22 40 36 39.75 39.75 48 52

Drum (in) 12 20 24 32 36 40 42 42 42

Outside (in) 20 31 26 44 42 46 46 54 58

Weight (lbs) 40 90 178 300 616 690 830 1,150 1,150

Cable OD (in)

0.300 5,490 12,633 19,153 N/A N/A N/A N/A N/A N/A

0.325 4,827 11,180 15,782 41,010 41,010 N/A N/A N/A N/A

0.350 3,955 9,264 13,561 36,943 41,010 N/A N/A N/A N/A

0.375 3,513 8,205 11,675 32,060 41,010 N/A N/A N/A N/A

0.400 3,088 7,193 10,674 28,019 41,010 N/A N/A N/A N/A

0.425 2,682 6,334 8,962 25,459 38,016 41,010 N/A N/A N/A

0.450 2,359 5,615 8,052 21,786 34,120 41,010 N/A N/A N/A

0.475 2221 4,843 7,336 19,938 29,975 38,758 41,010 N/A N/A

0.500 1976 4,728 6,642 18,147 26,800 34,546 41,010 N/A N/A

0.525 1689 4,090 5,832 16,419 24,535 31,882 38,790 41,010 N/A

0.550 1614 3,568 5,335 14,759 22,682 28,386 34,901 41,010 N/A

0.575 1,398 3,385 5,130 13,368 19,845 26,291 32,524 41,010 N/A

0.600 1,372 2,973 4,529 12,034 18,446 24,249 30,195 41,010 N/A

0.625 N/A 2,868 4,078 11,787 16,785 22,267 27,919 41,010 N/A

0.650 N/A 2,761 3,886 10,518 15,469 20,688 24,928 41,010 N/A

0.675 N/A 2,385 3,465 9,475 15,069 18,826 22,824 39,850 41,010

0.700 N/A 2,286 3,390 9,235 13,801 17,347 21,172 37,129 40,405

0.725 N/A 1,941 2,992 8,249 12,578 15,917 20,630 34,999 37,650

0.750 N/A 1,903 2,918 8,015 11,647 15,770 19,398 32,903 35,473

0.775 N/A 1,811 2,843 7,090 11,268 14,388 17,836 30,349 33,334

0.800 N/A 1,771 2,475 7,004 10,376 13,061 16,329 28,834 31,237

0.825 N/A 1,467 2,404 6,134 10,003 12,905 15,199 26,871 29,187

Yellow highlighted items cannot be used with armored cable. Orange highlighted items are limited to the cable production length.

Wooden Reel Chart

Page 111: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

111

AD

DITIO

NA

L RESO

UR

CES

Wooden Reel Length (feet)

Flange (in) 29.5 PLY 38 48 59 72 78 85 96 96

Traverse (in) 18 27 22 40 36 39.75 39.75 48 52

Drum (in) 12 20 24 32 36 40 42 42 42

Outside (in) 20 31 26 44 42 46 46 54 58

Weight (lbs) 40 90 178 300 616 690 830 1,150 1,150

Cable OD (in)

0.850 N/A 1,431 2,065 6,049 9,155 11,637 14,694 24,960 27,188

0.875 N/A 1,394 2,080 5,833 9,012 11,477 13,610 23,106 25,245

0.900 N/A 1,403 2,013 5,154 8,198 10,513 13,420 21,721 23,361

0.925 N/A 1,365 1,943 5,070 7,850 10,112 12,083 21,104 23,173

0.950 N/A 1,097 1,712 4,984 7,088 9,203 11,889 19,764 21,345

0.975 N/A 1,064 1,649 4,350 6,948 9,044 10,897 18,454 19,960

1.000 N/A 1,070 1,660 4,270 6,405 8,177 10,705 18,239 19,758

1.025 N/A N/A 1,596 4,188 6,270 8,022 9,757 16,603 18,047

1.050 N/A N/A 1,317 4,104 6,133 7,864 9,568 16,380 17,836

1.075 N/A N/A 1,325 3,527 5,449 7,051 8,666 15,165 16,544

1.100 N/A N/A 1,333 3,450 5,318 7,096 8,725 14,941 16,331

1.125 N/A N/A 1,274 3,372 5,352 6,943 8,540 13,770 15,082

1.150 N/A N/A 1,282 3,293 4,708 6,173 7,680 13,547 14,868

1.175 N/A N/A 1,032 3,311 4,584 6,027 7,501 12,425 13,667

1.200 N/A N/A 1,037 2,791 4,611 6,062 7,548 12,517 13,455

1.225 N/A N/A N/A 2,719 4,484 5,338 6,735 11,428 12,307

1.250 N/A N/A N/A 2,732 3,894 5,200 6,563 11,213 12,098

1.275 N/A N/A N/A 2,660 3,916 5,228 6,601 10,994 11,885

1.300 N/A N/A N/A 2,586 3,797 5,087 5,838 9,970 11,078

1.325 N/A N/A N/A 2,598 3,817 4,577 5,870 10,036 10,873

1.350 N/A N/A N/A 2,138 3,696 4,447 5,706 9822 10,664

Yellow highlighted items cannot be used with armored cable. Orange highlighted items are limited to the cable production length.

Wooden Reel Chart

Page 112: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

112

AD

DIT

ION

AL

RES

OU

RCE

S

Wooden Reel Chart

Wooden Reel Length (meters)

Flange (in) 29.5 PLY 38 48 59 72 78 85 96 96

Traverse (in) 18 27 22 40 36 39.75 39.75 48 52

Drum (in) 12 20 24 32 36 40 42 42 42

Outside (in) 20 31 26 44 42 46 46 54 58

Weight (lbs) 40 90 178 300 616 690 830 1,150 1,150

Cable OD (mm)

8.0 1,509 3,464 5,137 12,500 12,500 N/A N/A N/A N/A

8.5 1,332 3,104 4,492 12,110 12,500 N/A N/A N/A N/A

9.0 1,187 2.796 4,148 11,097 12,500 N/A N/A N/A N/A

9.5 1,070 2,500 3,557 9,766 12,500 N/A N/A N/A N/A

10.0 937 2,217 3.240 9,006 12,500 N/A N/A N/A N/A

10.5 910 1,979 2,990 7,872 11.906 12,500 N/A N/A N/A

11.0 804 1,909 2,692 7,252 11,090 12,500 N/A N/A N/A

11.5 703 1,686 2,459 6,651 9,888 12,500 N/A N/A N/A

12.0 695 1,501 2,233 6,070 9,244 11,938 12,500 N/A N/A

12.5 600 1,436 2,016 5,579 8,613 11,057 12,500 N/A N/A

13.0 591 1,264 1,945 5,105 7,996 9,906 12,500 N/A N/A

13.5 502 1,226 1,784 4,954 7,057 9,213 11,709 12,500 N/A

14.0 493 1,066 1,587 4,501 6,590 8,658 10,645 12,500 N/A

14.5 426 1,053 1,561 4,127 6,452 7,998 9,892 12,500 N/A

15.0 417 1,016 1,413 3,983 5,899 7,471 9,299 12,500 N/A

15.5 N/A 890 1,387 3,628 5,462 6,956 8,718 12,500 N/A

16.0 N/A 856 1,211 3,286 5,128 6,802 8,150 12,500 N/A

16.5 N/A 842 1,185 3,206 4,715 6,305 7,597 12,500 N/A

17.0 N/A 726 1,054 2,883 4,582 5,824 7,414 12,111 12,500

17.5 N/A 713 1,029 2,854 4,270 5,359 6,879 11,420 12,413

18.0 N/A 699 1,037 2,774 3,887 5,306 6,477 10,743 11,705

18.5 N/A 593 913 2,472 3,839 4,858 5,972 10,081 11,012

19.0 N/A 580 889 2,442 3,548 4,804 5,908 10,020 10,803

Yellow highlighted items cannot be used with armored cable. Orange highlighted items are limited to the cable production length.

Page 113: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

113

AD

DITIO

NA

L RESO

UR

CES

Wooden Reel Chart

Wooden Reel Length (feet)

Flange (in) 29.5 PLY 38 48 59 72 78 85 96 96

Traverse (in) 18 27 22 40 36 39.75 39.75 48 52

Drum (in) 12 20 24 32 36 40 42 42 42

Outside (in) 20 31 26 44 42 46 46 54 58

Weight (lbs) 40 90 178 300 616 690 830 1,150 1,150

Cable OD (in)

0.300 5,490 12,633 19,153 N/A N/A N/A N/A N/A N/A

0.325 4,827 11,180 15,782 41,010 41,010 N/A N/A N/A N/A

0.350 3,955 9,264 13,561 36,943 41,010 N/A N/A N/A N/A

0.375 3,513 8,205 11,675 32,060 41,010 N/A N/A N/A N/A

0.400 3,088 7,193 10,674 28,019 41,010 N/A N/A N/A N/A

0.425 2,682 6,334 8,962 25,459 38,016 41,010 N/A N/A N/A

0.450 2,359 5,615 8,052 21,786 34,120 41,010 N/A N/A N/A

0.475 2221 4,843 7,336 19,938 29,975 38,758 41,010 N/A N/A

0.500 1976 4,728 6,642 18,147 26,800 34,546 41,010 N/A N/A

0.525 1689 4,090 5,832 16,419 24,535 31,882 38,790 41,010 N/A

0.550 1614 3,568 5,335 14,759 22,682 28,386 34,901 41,010 N/A

0.575 1,398 3,385 5,130 13,368 19,845 26,291 32,524 41,010 N/A

0.600 1,372 2,973 4,529 12,034 18,446 24,249 30,195 41,010 N/A

0.625 N/A 2,868 4,078 11,787 16,785 22,267 27,919 41,010 N/A

0.650 N/A 2,761 3,886 10,518 15,469 20,688 24,928 41,010 N/A

0.675 N/A 2,385 3,465 9,475 15,069 18,826 22,824 39,850 41,010

0.700 N/A 2,286 3,390 9,235 13,801 17,347 21,172 37,129 40,405

0.725 N/A 1,941 2,992 8,249 12,578 15,917 20,630 34,999 37,650

0.750 N/A 1,903 2,918 8,015 11,647 15,770 19,398 32,903 35,473

0.775 N/A 1,811 2,843 7,090 11,268 14,388 17,836 30,349 33,334

0.800 N/A 1,771 2,475 7,004 10,376 13,061 16,329 28,834 31,237

0.825 N/A 1,467 2,404 6,134 10,003 12,905 15,199 26,871 29,187

Yellow highlighted items cannot be used with armored cable. Orange highlighted items are limited to the cable production length.

Page 114: Outdoor Cables - Prysmian Group · 1 GbE Dist (m) 10 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ G3 = OM3 BIF

Prysmian Group

LINKING the FUTURE

For more information, visit:website: na.prysmiangroup.com/telecom

+1-800-669-0808

2018 Telecom Catalog – Outdoor Cables_v1