Betriebsanleitung Operating instructions WISI TOPLINE HEADEND OV 75M Grundmodul / Basic module - Statischer / statically Remultiplexer REMUX (XX11) 2) - Dual QAM channel transmodulator - mit/with NIT 1) CS 76 (XX21) 2) ohne/without NIT (XX31) 2) - COFDM channel transmodulator (XX41) 1. Durchschleifeingang F Looped-through input F 2. Durchschleifausgang F Looped-through output F 3. Optional / Option abhängig vom Eingangsmodul dep. on input module 4. Programmier-Schnittstelle Mini-DIN Programming interface 5. Befestigungsschraube Fixing screw 6. Anzeige / Display 7. Bedienfeld / Control panel 8. DC-Versorgungsstecker DC connector 2 module slots for input modules 3) - DVB-S, - DVB-S2, - DVB-T, - DVB-C, - Audio/Video Encoder, - ASI in-/ output, - ASI dual input, - Fast Ethernet input (IP) - SDI Integrated stuffing unit for constant output data rate Integrated transportstream (SI, NIT) handling Output configuration loop/single switchable Connector for remote management (OV51A / 52). 1) 256 PID filter, NIT handling, Stuffing with PCR correction 2) Refer to ordering informations 3) Factory setting! OC/1-OT-595 3 4 5 6 7 1 2 8 2 Modulsteckplätze zur Aufnahme der Eingangsmodule 3) - DVB-S, - DVB-S2, - DVB-T, - DVB-C, - Audio/Video Encoder, - ASI in-/ output, - ASI dual input, - Fast Ethernet input (IP) - SDI Stuffing zur Einstellung einer konstanten Ausgangs- Datenrate Transportstrom (SI, NIT) Handling Einzel -/ Durchschleifbetrieb schaltbar Anschluß für Remote management (OV51A / 52) 1) 256 PID-Filter, NIT-Bearbeitung, Stuffing mit PCR-Korrekt. 2) siehe Bestellinformationen 3) Im Werk voreingestellt! 046 319 Upgrade: www.wisi.de - Service - Download (password login)

Upload: others

Post on 18-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 1 -

BetriebsanleitungOperating instructions

WISI TOPLINE HEADEND OV 75M Grundmodul / Basic module - Statischer / statically Remultiplexer REMUX (XX11)2) - Dual QAM channel transmodulator - mit/with NIT1) CS 76 (XX21)2)

ohne/without NIT (XX31)2)

- COFDM channel transmodulator (XX41)

1. Durchschleifeingang F Looped-through input F 2. Durchschleifausgang F Looped-through output F

3. Optional / Option abhängig vom Eingangsmodul dep. on input module

4. Programmier-Schnittstelle Mini-DIN Programming interface

5. Befestigungsschraube Fixing screw

6. Anzeige / Display

7. Bedienfeld / Control panel

8. DC-Versorgungsstecker DC connector

2 module slots for input modules3)

- DVB-S, - DVB-S2,

- DVB-T, - DVB-C,

- Audio/Video Encoder, - ASI in-/ output,

- ASI dual input, - Fast Ethernet input (IP)

- SDI

Integrated stuffing unit for constant output data rate

Integrated transportstream (SI, NIT) handling

Output configuration loop/single switchable

Connector for remote management (OV51A / 52).

1) 256 PID filter, NIT handling, Stuffing with PCR correction2) Refer to ordering informations3) Factory setting! OC/1-OT-595

3

4

5

6

7

12

8

2 Modulsteckplätze zur Aufnahme der Eingangsmodule3)

- DVB-S, - DVB-S2,

- DVB-T, - DVB-C,

- Audio/Video Encoder, - ASI in-/ output,

- ASI dual input, - Fast Ethernet input (IP)

- SDI

Stuffing zur Einstellung einer konstanten Ausgangs-

Datenrate

Transportstrom (SI, NIT) Handling

Einzel -/ Durchschleifbetrieb schaltbar

Anschluß für Remote management (OV51A / 52)

1) 256 PID-Filter, NIT-Bearbeitung, Stuffing mit PCR-Korrekt.2) siehe Bestellinformationen3) Im Werk voreingestellt!

046 319Upgrade: www.wisi.de - Service - Download (password login)

Page 2: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 2 -

Anschlussübersicht / Connections

Kanal B Channel

Kanal AChannel

F-Anschlüsse / ConnectorsDVB-S / DVB-S2 / DVB-T / DVB-C Module / Modules

Audio rechts / right (rot / red)Audio links / left (weiss / white)

Video (gelb / yellow)Kanal A Channel

Cinch-Anschlüsse / ConnectorsAV-MPEG Modul / Module

BNC-Anschlüsse / ConnectorsASI Modul / Module

out

inKanal A Channel

ASI

BNC, Klinke 3,5 mm Anschlüsse / BNC, phone jack 3.5 mm ConnectorsSDI Modul / Module

Serial Digital Video

Audio (Klinke 3,5mm phone jack)

Kanal A Channel

RJ-Anschluss / ConnectorIP Modul / Module

Kanal A Channel

RJ 45

Page 3: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 3 -

? ? ? ? ? ? Signal ?

Warnhinweis

Dieses kann folgende Ursachen haben:1. kein Eingangssignal. 2. Eingangsfrequenz falsch. 3. QPSK-Symbolrate falsch.

Inhaltsverzeichnis / Index

Beschreibung Anschlüsse / Tasten 1- Beschreibung optionale Anschlüsse 2 Auflistung der Geräteeigenschaften 1Werkseitige Einstellungen 1

Blockdarstellung 40 Bedienung Grundmodule

- Anschlussübersicht 2

- Dual QAM 4- REMUX 5- COFDM Remux-Mode 6-7 Hierarchical-Mode 8-9 NonHierarchical-Mode 10-11 DVBT-Repeater-Mode 12

Bedienung Eingangsmodule- DVB-S 13 - DVB-S2 13- DVB-T 14- DVB-C 14- AV-MPEG 15- ASI in/out 15- IP (100 Mb) 16- SDI - MPEG 17

Technische Daten - Dual QAM - COFDM 32

- REMUX 33- DVB S 34 - DVB S2 34- DVB-T 34- DVB-C 35- AV-MPEG 35 - ASI in/out 36- IP (100 Mb) 36- SDI - MPEG 37

Bestellhinweise 38- Kanalschlüssel 38

Description of connectors / buttons 1 - Description of option. connectors 2Feature list 1Factory settings 1

Block diagram 40 Operation basic modules

- Connections 2

- Dual QAM 18- REMUX 19- COFDM Remux-Mode 20-21 Hierarchical-Mode 22-23 NonHierarchical-Mode 24-25 DVBT-Repeater-Mode 26

Operation input modules- DVB-S 27- DVB-S2 27- DVB-T 28- DVB-C 28- AV-MPEG 29- ASI in/out 29- IP (100 Mb) 30- SDI - MPEG 31Specifications - Dual QAM - COFDM 32

- REMUX 33 - DVB S 34 - DVB S2 34- DVB-T 34- DVB-C 35- AV-MPEG 35 - ASI in/out 36- IP (100 Mb) 36- SDI - MPEG 37 Ordering information 38 - Key code 38

? ? ? ? ? ? Signal ?

Note

Displaying :1. No input signal. 2. Input frequency incorrect. 3. QPSK symbol rate incorrect.

Overfl siehe Bedienung REMUXbusy blinkt während des Init-Laufes. Keine Eingabe möglich, bis busy erlischt.

Overfl refer to operation REMUXWhile initialising, busy flashes. Control panel locked till Busy is off: Control panel unlocked.

Page 4: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 4 -

nur beiKanal A*Kanal B**

OV75M A/B=Kanal1237MHz= Eingangsfrequenz A/B479.00=Ausgangsfrequenz A/B,<1.0e-4=BER, Anzeige alternierend

Channel

OV75MV1.00busy

Kanal A/B

F-Out*

Offset**

45-862 MHz, 1-MHz-Schritte

4-8 MHz- Ausgangskanalabstand, Bsp.:Kanal A = 471,25 MHz + 8MHz Offset=Kanal B

loop = Durchschleifbetriebsingle = Einzelausgang

1.000-7.499 kBaud?Symbolrate? Wert liegt ausserhalb des Einstellbereiches????? siehe Warnhinweis

auto/on/off : auto:QAM-Signal schaltet ab, wenn Bedingung im Warnhinweis erfüllt ist. on: Signal schaltetnicht ab; off: Signal schaltet ab.

OUT-Att* 0-10 dB Augangspegel, 1-dB-Schritte

OutConf*

Stuffin on, off - autom. Einfügen von Datenbits

QAMRate

QAMCarr

QAMSpec normal / inverse

PIDFlt 0-9 0-9, 10 Filter, Eingabe in Hex / off

Modules* Anzeige der eingesetzten ModuleA: DVBS - ModulB: DVBS - ModulDual-QAM

Mod-No* Anzeige Modulnummer 0-9

Version* Anzeige Version Grundgerät, Software ModulSoftware version QAM-Modulinterne Daten

ModVers Anzeige Hard- Softwareversion EingangsmoduleA: DVBS - ModulS1.0003 - SoftwareversionH1.0000 - Hardwareversion

OV75MV1.00Ch. A

Hier - Einstellungen für Eingangsmodul einfügen

16, 32, 64, 128, 256 QAM ModulationsartQAMMode

Op-ID Operator ID, 0x0001-0xFFFF, Eingabe in Hex / off

(1)

(1)

(2)

(2)

VersionV 1.00160702000

Einstellungen Dual QAM (Kanalschlüssel XX2/3X mit/ohne Transportstream handling)

BedienungAuswahl des Menüpunktes und Ein-

stellen der Ziffern in entsprechen-

der Menüzeile mit den UP/DOWN-

Tasten . Eingabe der Werte

und Ein- Ausstieg in die Menüzeile

Speichern: Automatisch nach dem

Einstellen. Nach einem Netzausfall

bleiben alle Daten erhalten.

Module mit TS-Handling

1) OP-ID und PIDFlt werden bei Wechsel der Eingangsfre-quenz auf OFF gesetzt!

2) nur in Dual QAM mit TS handling und DVB-S und/oder ASI, DVB-S2 Modulen!

Page 5: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 5 -

OV75M A/B=Kanal1237 MHz= Eingangsfrequenz A/B471.00=Ausgangsfrequenz BER <1.0e-4=Bitfehlerrate

Channel

OV75MV1.00busy

Eingangskanal A/B

F-Out* 45-862 MHz, 1-MHz-Schritte

loop = Durchschleifbetriebsingle = Einzelausgang

1.000-7.499 kBaud?Symbolrate? Wert liegt ausserhalb des Einstellbereiches????? siehe Warnhinweis

auto/on: auto:QAM-Signal schaltet ab, wenn Bedingung im Warnhinweis erfüllt ist. on: Signal schaltet nicht ab

Out-Att* 0-10 dB Augangspegel, 1-dB-Schritte

OutConf*

QAMRate*

QAMCarr*

QAMSpec* normal / inverse

Modules*

Mod-No* Anzeige Modulnummer 0-9

Version*

Overflow-Zähler zeigt die Häufigkeit des "Überlaufens"an. Reset des Zählers mit

ModVers

Program Die Liste zeigt die Programmnamen des empfangenen Transponders an. Auswahl der Programme mit Pfeiltaste . Ein * bestätigt die Selektion. Je Kanal muß mindestens 1 Programm selektiert sein.Ist die Summendatenrate zu hoch, kommt die Meldung: !Overfl.nach Verlassen des Menüs. Programmanzahl reduzieren.

MUXStat Anzahl der selektierten Programme auf Kanal A/BMUX on - Statusanzeige

Hier - Einstellungen für Eingangsmodul einfügen

OV75MV1.00

Mod No /Mod init /

REMUX init

!Overflow

QAMMode* 16, 32, 64, 128, 256 QAM Modulationsart

Anzeige der eingesetzten Module A:DVBS - Modul B:DVBS - Modul Remux

T=TVR=Radio = verschlüsselt

Version Grundmodul, Softwareversion ModulSoftwareversion QAM-ModulOverflow Zähler

VersionV 1.00160702000...99

Anzeige Hard- Softwareversion EingangsmoduleA: DVBS - ModulS1.0003 - SoftwareversionH1.0000 - Hardwareversion

BedienungAuswahl des Menüpunktes und

Einstellen der Ziffern in ent-

sprechender Menüzeile mit den

UP/DOWN-Tasten . Eingabe

der Werte und Ein- Ausstieg in die

Menüzeile

Speichern: Automatisch nach dem

Einstellen. Nach einem Netzausfall

bleiben alle Daten erhalten.

Einstellungen Remux-QAM (Kanalschlüssel XX11)

nur beiKanal A*Kanal B**

Hinweis: Verschlüsselte Programme werden nur im Kanal A durchgereicht.

Page 6: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 6 -

Einstellungen COFDM Remux-Mode (Kanalschlüssel XX41)

OV75M A/B=Kanal476MHz= Eingangsfrequenz A/B479.00=Ausgangsfrequenz A/B,<1.0e-4=BER, Anzeige alternierend

Channel

OV75MV1.00busy

Kanal A/B

Mode* Remux, Betriebsart RemultiplexerNonHier, Betriebsart: NonHierarchischer Hier, Betriebsart: Hierarchischer DVBTRep, Repeater-Mode, wenn DVB-T-Modul gesteckt

OV75M AV1.00busy

Hier - Einstellungen für Eingangsmodul einfügen

F-Out* 45-862 MHz, 0.25-MHz-Schritte

loop = Durchschleifbetrieb, single = Einzelausgang

auto/on: auto:COFDMCarrier-Signal schaltet ab, wenn Bedingung im Warnhinweis erfüllt ist. on: Schaltet nicht ab

Out-Att* 0-16 dB Augangspegel, 1-dB-Schritte

OutConf*

Out-BW*

COFDMCa*

COFDMSp* normal / inverse COFDM-Spektrum

Modules*

Mod-No* Anzeige Modulnummer 0-9

Version*

Overflow-Zähler zeigt die Häufigkeit des "Überlaufens"an. Reset des Zählers mit

ModVers

Program Die Liste zeigt die Programmnamen des empfangenen Transponders an. Auswahl der Programme mit Pfeiltaste . Ein * bestätigt die Selektion. Je Kanal muß mindestens 1 Programm selektiert sein.Summendatenrate zu hoch: !Overfl.nach Verlassen des Menüs erscheint. Programmanzahl reduzieren. Anzeigen: T=TV; R=Radio; = verschlüsselt

MUXStat Anzahl der selektierten Programme auf Kanal A/BMUX on - Statusanzeige

QAMMode* 16 QAM, 64 QAM, QPSK Modulationsart

A:DVBT - Modul - Anzeige der eingesetzten Module B:DVBS - Modul

Version Grundmodul, Softwareversion Modulinterne DatenOverflow Zähler

VersionV 1.00 110901200...99

Anzeige Hard- Softwareversion EingangsmoduleA: DVBS - ModulS1.0003 - SoftwareversionH1.0000 - Hardwareversion

5, 6, 7, 8 MHz = Ausgangsbandbreite

Coderat 1/2, 2/3, 3/4, 5/6, 7/8 Coderate

k-Mode* 2k, 8k k-Mode

Guardin* 1/4, 1/8, 1/16, 1/32 Guard-Intervall

NIT-Ins On, off Network Information Table Eingabe

NetName Netzwerkname 7stellig

off oder HEX code 0 x 0000 Network identifier F F F F

OrgTsId

NetwId

offoder HEX code 0 x 0000 Transport Stream identifier F F F F

TsId

A

off oder HEX code 0 x 0000 Original Transport Stream F F F F Identifier

nur beiKanal A*Kanal B** B

Hinweis: Einstellungen, die mit A markiert sind.Einige SetTopBoxen benö-tigen Zugriff auf die NIT-Informationen, um den Transportstrom korrekt dar-zustellen. Ab COFDM-Version 11...

Werkseitig: auf on

Page 7: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 7 -

OV75M A/B=Kanal476MHz= Eingangsfrequenz A/B479.00=Ausgangsfrequenz A/B,<1.0e-4=BER, Anzeige alternierend

Channel

OV75MV1.00busy

Kanal A/B

Mode* Remux, Betriebsart RemultiplexerNonHier, Betriebsart: NonHierarchischer Hier, Betriebsart: Hierarchischer DVBTRep, Repeater-Mode, wenn DVB-T-Modul gesteckt

OV75M AV1.00busy

Hier - Einstellungen für Eingangsmodul einfügen

F-Out* 45-862 MHz, 0.25-MHz-Schritte

loop = Durchschleifbetrieb, single = Einzelausgang

auto/on: auto:COFDMCarrier-Signal schaltet ab, wenn Bedingung im Warnhinweis erfüllt ist. on: Schaltet nicht ab

Out-Att* 0-16 dB Augangspegel, 1-dB-Schritte

OutConf*

Out-BW*

COFDMCa*

COFDMSp* normal / inverse COFDM-Spektrum

Modules*

Mod-No* Anzeige Modulnummer 0-9

Version*

Overflow-Zähler zeigt die Häufigkeit des "Überlaufens"an. Reset des Zählers mit

ModVers

Program Die Liste zeigt die Programmnamen des empfangenen Transponders an. Auswahl der Programme mit Pfeiltaste . Ein * bestätigt die Selektion. Je Kanal muß mindestens 1 Programm selektiert sein.Summendatenrate zu hoch: !Overfl.nach Verlassen des Menüs erscheint. Programmanzahl reduzieren. Anzeigen: T=TV; R=Radio; = verschlüsselt

MUXStat Anzahl der selektierten Programme auf Kanal A/BMUX on - Statusanzeige

QAMMode* 16 QAM, 64 QAM, QPSK Modulationsart

A:DVBT - Modul - Anzeige der eingesetzten Module B:DVBS - Modul

Version Grundmodul, Softwareversion Modulinterne DatenOverflow Zähler

VersionV 1.00 110901200...99

Anzeige Hard- Softwareversion EingangsmoduleA: DVBS - ModulS1.0003 - SoftwareversionH1.0000 - Hardwareversion

5, 6, 7, 8 MHz = Ausgangsbandbreite

Coderat 1/2, 2/3, 3/4, 5/6, 7/8 Coderate

k-Mode* 2k, 8k k-Mode

Guardin* 1/4, 1/8, 1/16, 1/32 Guard-Intervall

NIT-Ins On, off Network Information Table Eingabe

NetName Netzwerkname 7stellig

off oder HEX code 0 x 0000 Network identifier F F F F

OrgTsId

NetwId

offoder HEX code 0 x 0000 Transport Stream identifier F F F F

TsId

A

off oder HEX code 0 x 0000 Original Transport Stream F F F F Identifier

B

Page 8: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 8 -

Einstellungen COFDM Hierarchical-Mode (Kanalschlüssel XX41)

OV75M A/B=Kanal476 MHz= Eingangsfrequenz A/B479.00=Ausgangsfrequenz A/B,<1.0e-4=BER, Anzeige alternierend

Channel

OV75MV1.00busy

Kanal A/B

Mode* Remux, Betriebsart RemultiplexerNonHier, Betriebsart Hierarchischer Betrieb AUSHier, Betriebsart Hierarchischer Betrieb EIN

OV75M AV1.00busy

Hier - Einstellungen für Eingangsmodul einfügen

F-Out* 45-862 MHz, 0.25-MHz-Schritte

loop = Durchschleifbetrieb, single = Einzelausgang

Out-Att* 0-16 dB Augangspegel, 1-dB-Schritte

OutConf*

Out-BW*

HPProgr

MUXStat Anzahl der selektierten Programme auf Kanal A/BMUX on - Statusanzeige

QAMMode* 16 QAM, 64 QAM, QPSK Modulationsart

5, 6, 7, 8 MHz = Ausgangsbandbreite

LPProgr** Die Liste zeigt die Programmnamen des empfangenen Transponders an. Auswahl der Low Priority Programme mit Pfeiltaste .

LP CR** 1/2, 2/3, 3/4, 5/6, 7/8 Low Priority Coderatee

Die Liste zeigt die Programmnamen des empfangenen Transponders an. Auswahl der High priority Programmemit Pfeiltaste . Ein * bestätigt die Selektion. Je Kanal muß mindestens 1 Programm selektiert sein.Ist die Summendatenrate zu hoch, kommt die Meldung: !Overfl.nach Verlassen des Menüs. Programmanzahl reduzieren. Anzeigen: T=TV; R=Radio; = verschlüsselt

NIT-Ins On, off Network Information Table Eingabe

NetName Netzwerkname 7stellig

off oder HEX code 0 x 0000 Network identifier F F F F

OrgTsId

NetwId

offoder HEX code 0 x 0000 Transport Stream identifier F F F F

TsId

A

off oder HEX code 0 x 0000 Original Transport Stream F F F F Identifier

Bnur beiKanal A*Kanal B**

Hinweis: Einstellungen, die mit A markiert sind.Einige SetTopBoxen benö-tigen Zugriff auf die NIT-Informationen, um den Transportstrom korrekt dar-zustellen. Ab COFDM-Version

11...

Werkseitig: auf on

Bei zwei Frontend-Modulen kann einem Modul die Prio-rität zugewiesen werden.

Page 9: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 9 -

B

nur beiKanal A*Kanal B**

auto/on: auto:COFDMCarrier-Signal schaltet ab, wenn Bedingung im Warnhinweis erfüllt ist. on: Schaltet nicht abCOFDMCa*

COFDMSp* normal / inverse COFDMSpektrum

Modules*

Mod-No* Anzeige Modulnummer 0-9

Version*

Overflow-Zähler zeigt die Häufigkeit des "Überlaufens"an. Reset des Zählers mit

ModVers

A:DVBT - Modul - Anzeige der eingesetzten Module B:DVBS - Modul

Version Grundmodul, Softwareversion Modulinterne DatenOverflow Zähler

VersionV 1.00110901200...99

Anzeige Hard- Softwareversion EingangsmoduleA/B: DVBS - ModulS1.0003 - SoftwareversionH1.0000 - Hardwareversion

HP CR* 1/2, 2/3, 3/4, 5/6, 7/8 High Priority Coderate

k-Mode* 2k, 8k k-Mode

Guardin* 1/4, 1/8, 1/16, 1/32 Guard-Intervall

Alpha* alpha 1, 2, 4 Spreizung Constellationsdiagramm

Page 10: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 10 -

Einstellungen COFDM NonHierarchical-Mode (Kanalschlüssel XX41)

OV75M A=Kanal476 MHz= Eingangsfrequenz A479.00=Ausgangsfrequenz A,<1.0e-4=BER, Anzeige alternierend

OV75MV1.00busy

Mode* Remux, Betriebsart RemultiplexerNonHier, Betriebsart: NonHierarchischer für einFrontend-Modul ch AHier, Betriebsart: Hierarchischer

OV75M AV1.00busy

Hier - Einstellungen für Eingangsmodul einfügen

F-Out* 45-862 MHz, 0.25-MHz-Schritte

loop = Durchschleifbetrieb, single = Einzelausgang

auto/on: auto:COFDMCarrier-Signal schaltet ab, wenn Bedingung im Warnhinweis erfüllt ist. on: Schaltet nicht ab

Out-Att* 0-16 dB Augangspegel, 1-dB-Schritte

OutConf*

Out-BW*

COFDMCa*

COFDMSp* normal / inverse COFDMSpektrum

Modules*

Mod-No* Anzeige Modulnummer 0-9

Version*

Overflow-Zähler zeigt die Häufigkeit des "Überlaufens"an. Reset des Zählers mit

ModVers

MUXStat Anzahl der selektierten Programme auf Kanal AMUX on - Statusanzeige

QAMMode* 16 QAM, 64 QAM, QPSK Modulationsart

A:DVBT - Modul - Anzeige der eingesetzten Module

Version Grundmodul, Softwareversion Modulinterne DatenOverflow Zähler

VersionV 1.00110901200...99

Anzeige Hard- Softwareversion EingangsmoduleA: DVBT - ModulS1.0003 - SoftwareversionH1.0000 - Hardwareversion

5, 6, 7, 8 MHz = Ausgangsbandbreite

k-Mode* 2k, 8k k-Mode

Guardin* 1/4, 1/8, 1/16, 1/32 Guardintervall

Coderat 1/2, 2/3, 3/4, 5/6, 7/8 Coderate

NIT-Ins On, off Network Information Table Eingabe

NetName Netzwerkname 7stellig

off oder HEX code 0 x 0000 Network identifier F F F F

OrgTsId

NetwId

offoder HEX code 0 x 0000 Transport Stream identifier F F F F

TsId

A

off oder HEX code 0 x 0000 Original Transport Stream F F F F Identifier

nur beiKanal A*Kanal B** B

Hinweis: Einstellungen, die mit A markiert sind.Einige SetTopBoxen benö-tigen Zugriff auf die NIT-Informationen, um den Transportstrom korrekt dar-zustellen. Ab COFDM-Version

11...

Werkseitig: auf on

Page 11: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 11 -

OV75M A=Kanal476 MHz= Eingangsfrequenz A479.00=Ausgangsfrequenz A,<1.0e-4=BER, Anzeige alternierend

OV75MV1.00busy

Mode* Remux, Betriebsart RemultiplexerNonHier, Betriebsart: NonHierarchischer für einFrontend-Modul ch AHier, Betriebsart: Hierarchischer

OV75M AV1.00busy

Hier - Einstellungen für Eingangsmodul einfügen

F-Out* 45-862 MHz, 0.25-MHz-Schritte

loop = Durchschleifbetrieb, single = Einzelausgang

auto/on: auto:COFDMCarrier-Signal schaltet ab, wenn Bedingung im Warnhinweis erfüllt ist. on: Schaltet nicht ab

Out-Att* 0-16 dB Augangspegel, 1-dB-Schritte

OutConf*

Out-BW*

COFDMCa*

COFDMSp* normal / inverse COFDMSpektrum

Modules*

Mod-No* Anzeige Modulnummer 0-9

Version*

Overflow-Zähler zeigt die Häufigkeit des "Überlaufens"an. Reset des Zählers mit

ModVers

MUXStat Anzahl der selektierten Programme auf Kanal AMUX on - Statusanzeige

QAMMode* 16 QAM, 64 QAM, QPSK Modulationsart

A:DVBT - Modul - Anzeige der eingesetzten Module

Version Grundmodul, Softwareversion Modulinterne DatenOverflow Zähler

VersionV 1.00110901200...99

Anzeige Hard- Softwareversion EingangsmoduleA: DVBT - ModulS1.0003 - SoftwareversionH1.0000 - Hardwareversion

5, 6, 7, 8 MHz = Ausgangsbandbreite

k-Mode* 2k, 8k k-Mode

Guardin* 1/4, 1/8, 1/16, 1/32 Guardintervall

Coderat 1/2, 2/3, 3/4, 5/6, 7/8 Coderate

NIT-Ins On, off Network Information Table Eingabe

NetName Netzwerkname 7stellig

off oder HEX code 0 x 0000 Network identifier F F F F

OrgTsId

NetwId

offoder HEX code 0 x 0000 Transport Stream identifier F F F F

TsId

A

off oder HEX code 0 x 0000 Original Transport Stream F F F F Identifier

B

Die NIT - Network Information Table enthält die Spezifikationen der Transponder und der Programme, die in einem Datenstrom übertragen werden, wie z. Bsp- Sendefrequenz - Symbolrate- Informationen für Receiver und Settop-Boxen

NIT - Information

Abb. Auszug aus TS-Analyse mit OTxxxx Transport Stream Multiplexer

Page 12: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 12 -

Einstellungen COFDM DVBT-Repeater-Mode (Kanalschlüssel 4041)

OV75M A/B=Kanal1237MHz= Eingangsfrequenz A/B479.00=Ausgangsfrequenz A/B,<1.0e-4=BER, Anzeige alternierend

OV75MV1.00busy

Mode DVBTRep, Repeater-Mode, wenn DVB-T-Modul gesteckt ist. Eingangsparameter werden an COFDM weitergereicht!Remux, Betriebsart RemultiplexerNonHier, Betriebsart: NonHierarchischer Hier, Betriebsart: Hierarchischer

OV75M AV1.00busy

Hier - Einstellungen für DVB-T-Eingangsmodul einfügen

F-Out 45-862 MHz, 0.25-MHz-Schritte

loop = Durchschleifbetrieb, single = Einzelausgang

auto/on: auto:COFDMCarrier-Signal schaltet ab, wenn Bedingung im Warnhinweis erfüllt ist. on: Signal schaltet nicht ab.

Out-Att 0-16 dB Augangspegel, 1-dB-Schritte

OutConf

COFDMCa

COFDMSp normal / inverse COFDMSpektrum

Modules

Mod-No Anzeige Modulnummer 0-9

Version

Overflow-Zähler zeigt die Häufigkeit des "Überlaufens"an. Reset des Zählers mit

ModVers

MUXStat Anzahl der selektierten Programme MUX on - Statusanzeige

A:DVBT - Modul - Anzeige der eingesetzten Module

Version Grundmodul, Softwareversion Modulinterne DatenOverflow Zähler

VersionV 1.00 110901200...99

Anzeige Hard- Softwareversion EingangsmoduleA: DVBT - ModulS1.0003 - SoftwareversionH1.0000 - Hardwareversion

Page 13: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 13 -

Sat-IF 950-2150 MHz Auswahl der SAT-ZF, 1-MHz-Schritte

SymRate

BerRate

2.000-45.000 kSps Symbolrate

<1.0 e-4Die BER ist ein Mass für die Übertragungsfehler und damit für die Signalqualität.<1.0 e-4 = sehr geringe Fehler1.0 e-3 = geringe Anzahl von Fehlern1.0 e-2 = Schaltschwelle für Anzeige: Signal? Signal zu schlecht!41,25 Mb = Eingangsdatenrate

DVBmode S QPSK - 1/2, 2/3, 3/4, 5/6, 7/8S2 8QPSK - 3/5, 2/3, 3/4, 5/6, 8/9, 9/10S2 QPSK - 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10

Pilot on / off

Einstellungen für Eingangsmodul

Sat-IF 950-2150 MHz Auswahl der SAT-ZF, 1-MHz-Schritte

SymRate 2.000-45.000 kSps Symbolrate

Einstellungen für Eingangsmodul

BerRate <1.0 e-4Die BER ist ein Mass für die Übertragungsfehler und damit für die Signalqualität.<1.0 e-4 = sehr geringe Fehler1.0 e-3 = geringe Anzahl von Fehlern1.0 e-2 = Schaltschwelle für Anzeige: Signal? Signal zu schlecht!41,25 Mb = Eingangsdatenrate

Einstellungen DVB-S (Kanalschlüssel 1XXX)

Einstellungen DVB-S2 (Kanalschlüssel 3XXX)

Eingangsmodule

Page 14: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 14 -

In-Freq 146-858 MHz Auswahl der Eingangsfrequenz, 0.25-MHz-Schritte

In-Offs

BerRate

Eingangs-Offset-166 kHz, 0, +166 kHz bei 8 MHz-125 kHz, 0, +125 kHz bei 7 MHz

<1.0 e-4Die BER ist ein Mass für die Übertragungsfehler und damit für die Signalqualität.<1.0 e-4 = sehr geringe Fehler1.0 e-3 = geringe Anzahl von Fehlern1.0 e-2 = Schaltschwelle für Anzeige:Signal? Signal zu schlecht!14,46 Mb = Eingangsdatenrate

In-BW Bandbreite 7 / 8 MHz

Einstellungen für Eingangsmodul

HierMod Hierarchie-Auswahl (ab "ModVers":H2.000)high (Priority)low (Priority)

In-ATT 0 dB, 20 dB Eingangsdämpfglied (ab "ModVers":H2.000)

Einstellungen DVB-T (Kanalschlüssel 4XXX)

Einstellungen DVB-C (Kanalschlüssel 5XXX)

In-Freq 50-862 MHz Auswahl der Eingangsfrequenz, 0.5-MHz-Schritte

In-Mode

BerRate

16, 32, 64, 128, 256 QAM

<1.0 e-4Die BER ist ein Mass für die Übertragungsfehler und damit für die Signalqualität.<1.0 e-4 = sehr geringe Fehler1.0 e-3 = geringe Anzahl von Fehlern1.0 e-2 = Schaltschwelle für Anzeige: Signal? Signal zu schlecht!38,15 Mb = Eingangsdatenrate

In-Att 0 dB, 20 dB Eingangsdämpfglied

Einstellungen für Eingangsmodul

SymRate 1750-7125 kSps Eingangssymbolrate Bei zu hoher Kanallast, selektives Kanalfilter in den HF-Eingang schalten.

Page 15: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 15 -

VidRate 3,0: 4,5; 6,0; 9,0 Mbit/s Ausgangs-Videodatenrate

A-Mode Stereo, JointSt, Dual, Single

Name Eingabe des Programm-Namens 7 stellig

Provid.

Einstellungen für Eingangsmodul

TP-Gen on / off blaues Testbild

Eingabe des Provider-Namens 7 stellig

TSID Transport Stream Identifier; Eingabe in HEX 0 x FFFF

SID Service Identifier; Eingabe in HEX 0 x FFFF

VidNorm PAL, NTSC, SECAM Videonorm auswählen!

Encode Aud/Vid = Eintrag in die TV-Liste des KabelreceiversAudio = Eintrag in die Radio-Liste des Kabelreceivers Encodiert nur das Audiosignal

Einstellungen AV-MPEG (Kanalschlüssel 6XXX)

Einstellungen ASI in/out (Kanalschlüssel 7XXX)

ASI loop

Einstellungen für Eingangsmodul

on / schaltet das ASI-Modul zwischen Frontend und QAM-Modulator (Kanal A). (B) wird abgeschaltet.off

A B

DVB-S ASI

Descrambler

A=on

QAMB=off

Hinweis: Sind mehrere AV-MPEG-oder SDI Module eingebaut, dürfen keine glei-chen HEX-Adressen verwendet werden.Dies gilt auch für mehrere Module in einer Kopfstelle!

Beispiel: ASI loop: on

Page 16: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 16 -

Einstellungen IP (100 Mb) (Kanalschlüssel 9XXX)

IPAddr 0 172 Cursor unter die einzustellende Zahl schieben und mit ändern. IP-Adresse einstellen

29 IP-Adresse einstellen

1 IP-Adresse einstellen

Einstellungen für Eingangsmodul

Port 0-65535 Port-Adresse einstellen

91 IP-Adresse einstellen

IPAddr 1

IPAddr 2

IPAddr 3

MCAddr 0

MCAddr 1

MCAddr 2

MCAddr 3

ARPTime Menü wird eingeblendet, wenn Multicast auf off steht. ARPTime: off / 2-255s einstellbar.

MCast

239 Cursor unter die einzustellende Zahl schieben und mit ändern. Multi-Cast-Adresse einstellen

255 Multi-Cast-Adresse einstellen

off/on Multi-Cast on/off

255 Multi-Cast-Adresse einstellen

255 Multi-Cast-Adresse einstellen

MACAddr. 00039800000E - Anzeige MAC-Adresse0.9905 - Anzeige FPGA-Version

172 - die einzustellende Adresse 0-3 wird in der obersten Zeile angezeigt172. 291. 91

Page 17: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 17 -

Einstellungen SDI- MPEG (Kanalschlüssel AXXX)

VidRate 3,0: 4,5; 6,0; 9,0 Mbit/s Ausgangs-Videodatenrate

A-Mode Stereo, JointSt, Dual, Single

Name Eingabe des Programm-Namens 7 stellig

Provid.

Einstellungen für Eingangsmodul

TP-Gen on / off blaues Testbild

Eingabe des Provider-Namens 7 stellig

TSID Transport Stream Identifier; Eingabe in HEX 0 x FFFF

SID Service Identifier; Eingabe in HEX 0 x FFFF

Encode Aud/Vid = Eintrag in die TV-Liste des KabelreceiversAudio = Eintrag in die Radio-Liste des Kabelreceivers Encodiert nur das Audiosignal

Aud-Grp analog, 7/8; 5/6; 3/4; 1/2 Auswahl der Audio-Gruppe

Aud-Vol -18 ... +18 dB 6-dB-Schritte

Hinweis: Sind mehrere AV-MPEG-oder SDI Module eingebaut, dürfen keine glei-chen HEX-Adressen verwendet werden.Dies gilt auch für mehrere Module in einer Kopfstelle!

Page 18: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 18 -

only atChannel A*Channel B**

OV75M A/B= channel1237MHz=Input frequency A/B479.00=output frequency A/B<1.0e-4=BER, alternating

Channel

OV75MV1.00busy

Channel A/B

F-Out*

Offset**

45-862 MHz, 1 MHz steps

4-8 MHz-OffsetExp.: Ch A = 471,25 MHz + 8-MHz-Offset = Ch B

loop = Loop through modesingle = Single output

1.000-7.499 kBaud?Symbol rate? Incorrect symbole rate????? refer to note

auto/on/off : auto:QAM signal switches off autom. on: signal doesn't switch off automatically.off: signal switches to off

Out-Att* 0-10 dB Output level, 1dB steps

OutConf*

Stuffin on, off - autom. insert of data bits

QAMRate

QAMCarr

QAMSpec normal / inverse

PIDFlt 0-9 0-9, 10 filter, Hex code / off

Modules* Displaying: modulesA: DVBS - moduleB: DVBS - moduleDual-QAM

Mod-No* Displaying: module number 0-9

Version* version of basic unit, software version modulesoftware version QAM moduleundocumented command

ModVers Displaying: hard and software version of input modulesA: DVBS - moduleS1.0003 - software versionH1.0000 - hardware version

Insert here - input modules settings

16, 32, 64, 128, 256 QAM type of modulation.QAMMode

OV75MV1.00Ch. A

(1)

(1) Op-ID Operator ID, 0x0001-0xFFFF, Hex. / off

(2)

(2)

VersionV 1.00160702000

Settings Dual QAM (Key code XX2/3X with/without transport stream handling)

OperationSelect the menu item and adjust the values in a menu line with the UP/DOWN keys . Enter values and enter and exit from menu lines with the LEFT/RIGHT keys .Saving: Data are saved automatically. Data are retained in the case of a power failure.

GB

Modules with TS handling

1) Setting the input frequency: the "OP-ID" and "PIDFlt turns to OFF

2) Only for Dual QAM with TS handling and DVB-S and/orASI, DVB-S2 modules

Page 19: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 19 -

OV75M A/B= channel1237MHz=Input frequency A/B 471.00=output frequency,BER <1.0 e-4= Bit error rate

Channel

OV75MV1.00busy

Input channel A/B

ProgramDisplays the list of transponder name. Select program with A * confirms the selected programmes.Important: Select one programme per channel If !Overfl is displayed, (total data rate to high) reduce the program numbers.

loop = Loop through modeSingle = Single output

1.000-7.499 kBaud?Symbol rate? Incorrect symbole rate????? refer to note

auto/on: auto:QAM signal switches off atom. (see note),on: signal doesn't switch off automatically.

Out-Att* 0-10 dB Output level, 1dB steps

OutConf*

QAMRate*

QAMCarr*

QAMSpec* normal / inverse

Modules* Displaying: modules A:DVBS - moduleB:DVBS - moduleRemux

Mod-No* Displaying: module number 0-9

Version*

ModVers Displaying: hard and software version of input modules A:DVBS - moduleS1.0003 - software versionH1.0000 - hardware version

F-Out* 45-862 MHz, 1 MHz steps

MUXStat Sum of selected programmes channel A/BMux on - displaying status of Remux

Insert here - input module settings

OV75MV1.00

Mod No/Mod init/

REMUX init

!Overflow

16, 32, 64, 128, 256 QAM type of modulationQAMMode*

Overflow counter shows the account of "overflows". Counter reset: press simultaneously

version of basic unit, software version modulesoftware version QAM moduleOverflow counter

VersionV 1.00160702000...99

T=tvR=radio = encrypted

OperationSelect the menu item and adjust the values in a menu line with the UP/DOWN keys . Enter values and enter and exit from menu lines with the LEFT/RIGHT keys .Saving: Data are saved automatically. Data are retained in the case of a power failure.

GB

Settings Remux-QAM (Key code XX11)

only atChannel A*Channel B**

Note: Encryted programmes are passed through only via channel A!

Page 20: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 20 -

Settings COFDM Remux mode (Key code XX41)

only atChannel A*Channel B**

OV75M A/B=channel1237MHz= input frequency A/B479.00=output frequency A/B,<1.0e-4=BER, alternating display

Channel

OV75MV1.00busy

Input channel A/B

Mode* Remux, Remultiplexer modeNonHier, NonHierarchical modeHier, Hierarchical mode DVBTRep, Repeater mode (available with DVB-T modul)

OV75M AV1.00busy

Please set all parameters of the frontend module settings

F-Out* 45-862 MHz, 0.25-MHz steps

loop = Loop thru mode , single = single output

auto/on : auto:COFDMCarrier signal switches off. On: signal doesn't switch off.

Out-Att* 0-16 dB output level, 1-dB steps

OutConf*

Out-BW*

COFDMCa*

COFDMSp* normal / inverse COFDMSpectrum

Modules*

Mod-No* Displaying module number 0-9

Version*

Overflow counter shows the account of "overflows".Counter reset: press simultaneously

ModVers

Program Displays the list of transponder name. Select program with. A * confirms the selection . Select programme per channel. Indication of !Overfl .shows: (total data rate to high) T=TV; R=Radio; = encrypted

MUXStat Sum of selected programmes ch A/BMUX on - displaying status of Remux

QAMMode* 16 QAM, 64 QAM, QPSK type of modulation

A:AV-MPEG - module - displaying modules B:AV-MPEG - module - displaying modules

basic unit version, software version moduleundocumented commandOverflow counter

VersionV 1.00110901200...99

Displaying: hard and software version of input modulesA: AV-MPEG - moduleS1.0003 - software versionH1.0000 - hardware version

5, 6, 7, 8 MHz = output bandwidth

Coderat 1/2, 2/3, 3/4, 5/6, 7/8 Code rate

k-Mode* 2k, 8k k mode

Guardin* 1/4, 1/8, 1/16, 1/32 Guard intervall

NIT-Ins On, off Network Information Table insertion

NetName network name 7 digits

off or set HEX code 0 x 0000 Network identifier F F F F

OrgTsId

NetwId

off or set HEX code 0 x 0000 Transport Stream Identifier F F F F

TsId

off or set HEX code 0 x 0000 Original Transport Stream F F F F Identifier

A

Output settings

GB B

Note: Settings marked with ASome SetTopBoxes on the mar-ket requires additional informa-tions about NIT to scan correct Transport Stream. Available from COFDM version 11..Factory setting: on

Page 21: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 21 -

OV75M A/B=channel1237MHz= input frequency A/B479.00=output frequency A/B,<1.0e-4=BER, alternating display

Channel

OV75MV1.00busy

Input channel A/B

Mode* Remux, Remultiplexer modeNonHier, NonHierarchical modeHier, Hierarchical mode DVBTRep, Repeater mode (available with DVB-T modul)

OV75M AV1.00busy

Please set all parameters of the frontend module settings

F-Out* 45-862 MHz, 0.25-MHz steps

loop = Loop thru mode , single = single output

auto/on : auto:COFDMCarrier signal switches off. On: signal doesn't switch off.

Out-Att* 0-16 dB output level, 1-dB steps

OutConf*

Out-BW*

COFDMCa*

COFDMSp* normal / inverse COFDMSpectrum

Modules*

Mod-No* Displaying module number 0-9

Version*

Overflow counter shows the account of "overflows".Counter reset: press simultaneously

ModVers

Program Displays the list of transponder name. Select program with. A * confirms the selection . Select programme per channel. Indication of !Overfl .shows: (total data rate to high) T=TV; R=Radio; = encrypted

MUXStat Sum of selected programmes ch A/BMUX on - displaying status of Remux

QAMMode* 16 QAM, 64 QAM, QPSK type of modulation

A:AV-MPEG - module - displaying modules B:AV-MPEG - module - displaying modules

basic unit version, software version moduleundocumented commandOverflow counter

VersionV 1.00110901200...99

Displaying: hard and software version of input modulesA: AV-MPEG - moduleS1.0003 - software versionH1.0000 - hardware version

5, 6, 7, 8 MHz = output bandwidth

Coderat 1/2, 2/3, 3/4, 5/6, 7/8 Code rate

k-Mode* 2k, 8k k mode

Guardin* 1/4, 1/8, 1/16, 1/32 Guard intervall

NIT-Ins On, off Network Information Table insertion

NetName network name 7 digits

off or set HEX code 0 x 0000 Network identifier F F F F

OrgTsId

NetwId

off or set HEX code 0 x 0000 Transport Stream Identifier F F F F

TsId

off or set HEX code 0 x 0000 Original Transport Stream F F F F Identifier

A

Output settings

B

Page 22: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 22 -

Settings COFDM Hierarchical mode (Key code XX41)

only atChannel A*Channel B**

OV75M A/B=channel476 MHz= input frequency A/B479.00=output frequency A/B,<1.0e-4=BER, alternating display

Channel

OV75MV1.00busy

Input channel A/B

Mode* Remux, Remultiplexer modeNonHier, NonHierarchical modeHier, Hierarchical mode. chA/B one of the modules gets the priority

OV75M AV1.00busy

Please set all parameters of the frontend modules

F-Out* 45-862 MHz, 0.25-MHz steps

loop = Loop thru mode, single = single output

Out-Att* 0-16 dB output level, 1-dB steps

OutConf*

Out-BW*

HP Progr*

MUXStat Sum of selected programmes ch A/BMUX on - displaying status

QAMMode*

5, 6, 7, 8 MHz = output bandwidth

LP Progr** Displays the list of transponder name. Select low priorityprogram with. A * confirms the selection. Select programme per channel. T=TV; R=Radio; = encrypted

LP CR** 1/2, 2/3, 3/4, 5/6, 7/8, Low Priority Code Rate

Displays the list of transponder name. Select high priorityprogram with. A * confirms the selection. Select programme per channel. Indication of !Overfl.shows: (total data rate to high) T=TV; R=Radio; = encrypted

16 QAM, 64 QAM, QPSK type of modulation

Output settings

NIT-Ins On, off Network Information Table insertion

NetName network name 7 digits

off or set HEX code 0 x 0000 Network identifier F F F F

OrgTsId

NetwId

off or set HEX code 0 x 0000 Transport Stream identifier F F F F

TsId

A

off or set HEX code 0 x 0000 Original Transport Stream F F F F Identifier

BGB

Note: Settings marked with ASome SetTopBoxes on the mar-ket requires additional informa-tions about NIT to scan correct Transport Stream. Available from COFDM version 11..Factory setting: on

Hierarchical mode supports two frontend modules ch A/B. Set priority to one of them.

Page 23: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 23 -

GB

B

auto/on: auto:COFDMCarrier signal switches off autom.on: signal doesn't switch off automatically.

COFDMCa*

COFDMSp* normal / inverse COFDMSpectrum

Modules*

Mod-No* Displaying module number 0-9

Version*

Overflow counter shows the account of "overflows".Counter reset: press simultaneously

ModVers

A:AV-MPEG - module - displaying modules B:AV-MPEG - module - displaying modules

basic unit version, software version moduleundocumented commandOverflow counter

VersionV 1.00110901200...99

Displaying: hard and software version of input modulesA: AV-MPEG - moduleS1.0003 - software versionH1.0000 - hardware version

k-Mode* 2k, 8k k mode

Guardin* 1/4, 1/8, 1/16, 1/32 Guard intervall

HP CR* 1/2, 2/3, 3/4, 5/6, 7/8 High Priority Coderate

Alpha* alpha 1, 2, 4 Spreding of constellation diagram

Page 24: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 24 -

GB

Settings COFDM NonHierarchical mode (Key code XX41)

only atChannel A*Channel B**

OV75M A=channel476 MHz= input frequency A479.00=output frequency A,<1.0e-4=BER, alternating display

OV75MV1.00busy

Mode* Remux, Remultiplexer modeNonHier, NonHierarchical mode (channel A - one frontend module)Hier, Hierarchical mode

OV75M AV1.00busy

F-Out* 45-862 MHz, 0.25-MHz steps

loop = Loop thru mode, single = single mode

Out-Att* 0-16 dB output level, 1-dB steps

OutConf*

Out-BW*

MUXStat Sum of selected programmes ch AMUX on - displaying status of Remux

5, 6, 7, 8 MHz = output bandwidth

Please set all parameters of the DVB-T frontend module

Output settings

auto/on: auto:COFDMCarrier signal switches off. On: signal doesn't switch off.

COFDMCa*

COFDMSp* normal / inverse COFDMSpectrum

Modules*

Mod-No* Displaying module number 0-9

Version*

Overflow counter shows the account of "overflows".Counter reset: press simultaneously

ModVers

QAMMode* 16 QAM 64 QAM, QPSK type of modulation

DVBT-MPEG - module - displaying modules

basic unit version, software version moduleundocumented commandOverflow counter

VersionV 1.00110901200...99

Displaying: hard and software version of input modulesA: DVBT - moduleS1.0003 - software versionH1.0000 - hardware version

k-Mode* 2k, 8k k mode

Guardin* 1/4, 1/8, 1/16, 1/32 Guard intervall

Coderat 1/2, 2/3, 3/4, 5/6, 7/8 Coderate

NIT-Ins On, off Network Information Table insertion

NetName network name 7 digits

off or set HEX code 0 x 0000 Network identifier F F F F

OrgTsId

NetwId

off or set HEX code 0 x 0000 Transport Stream identifier F F F F

TsId

A

off or set HEX code 0 x 0000 Original Transport Stream F F F F Identifier

B

NonHierarchical mode supports one frontend module ch A

Note: Settings marked with ASome SetTopBoxes on the mar-ket requires additional informa-tions about NIT to scan correct Transport Stream. Available from COFDM version 11..Factory setting: on

Page 25: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 25 -

OV75M A=channel476 MHz= input frequency A479.00=output frequency A,<1.0e-4=BER, alternating display

OV75MV1.00busy

Mode* Remux, Remultiplexer modeNonHier, NonHierarchical mode (channel A - one frontend module)Hier, Hierarchical mode

OV75M AV1.00busy

F-Out* 45-862 MHz, 0.25-MHz steps

loop = Loop thru mode, single = single mode

Out-Att* 0-16 dB output level, 1-dB steps

OutConf*

Out-BW*

MUXStat Sum of selected programmes ch AMUX on - displaying status of Remux

5, 6, 7, 8 MHz = output bandwidth

Please set all parameters of the DVB-T frontend module

Output settings

auto/on: auto:COFDMCarrier signal switches off. On: signal doesn't switch off.

COFDMCa*

COFDMSp* normal / inverse COFDMSpectrum

Modules*

Mod-No* Displaying module number 0-9

Version*

Overflow counter shows the account of "overflows".Counter reset: press simultaneously

ModVers

QAMMode* 16 QAM 64 QAM, QPSK type of modulation

DVBT-MPEG - module - displaying modules

basic unit version, software version moduleundocumented commandOverflow counter

VersionV 1.00110901200...99

Displaying: hard and software version of input modulesA: DVBT - moduleS1.0003 - software versionH1.0000 - hardware version

k-Mode* 2k, 8k k mode

Guardin* 1/4, 1/8, 1/16, 1/32 Guard intervall

Coderat 1/2, 2/3, 3/4, 5/6, 7/8 Coderate

NIT-Ins On, off Network Information Table insertion

NetName network name 7 digits

off or set HEX code 0 x 0000 Network identifier F F F F

OrgTsId

NetwId

off or set HEX code 0 x 0000 Transport Stream identifier F F F F

TsId

A

off or set HEX code 0 x 0000 Original Transport Stream F F F F Identifier

B

NIT - Information

Fig. extract of TS Analyzer OTxxxx Transport Stream Mul-tiplexer

The NIT – Network Information Table – contains the specifications of the transponders and the programs transmitted in the data stream, e.g.- Transmission frequency- Symbol rate- Information for receivers and set-top boxes

Page 26: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 26 -

Setting COFDM DVBT-Repeater mode (Key code 4041)

OV75M A/B=channel476 MHz= input frequency A/B479.00=output frequency A/B,<1.0e-4=BER, alternating display

OV75MV1.00busy

Mode* DVBTRep, Repeater mode (available with DVB-T module). Input parameters are passed on toCOFDM Remux, Remultiplexer modeNonHier, NonHierarchical modeHier, Hierarchical mode

OV75M AV1.00busy

Please set all parameters of the DVB-T frontend module

F-Out 45-862 MHz, 0.25-MHz steps

loop = Loop thru mode, single = single output

auto/on: auto:COFDMCarrier signal switches off. On: signal doesn't switch off.

Out-Att 0-16 dB output level, 1-dB steps

OutConf

COFDMCa

COFDMSp normal / inverse COFDMSpectrum

Modules

Mod-No Displaying module number 0-9

Version

Overflow counter shows the account of "overflows".Counter reset: press simultaneously

ModVers

MUXStat Sum of selected programmes MUX on - displaying status of Remux

A:DVBT - module - displaying modules

basic unit version, software version moduleundocumented commandOverflow counter

VersionV 1.00110901200...99

Displaying: hard and software version of input modulesA: DVBT - moduleS1.0003 - software versionH1.0000 - hardware version

Output settings

GB

You require this mode when only one DVB-T front-end mo-dule is plugged in. In this mode input parameters as e.g. BW and all other parameters are co-pied to the output. Advantage: You have to set only the output frequency/attenuation parame-ters.

Page 27: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 27 -

DVB-S module settings

Sat-IF 950-2150 MHz Selection of Sat-IF, 1 MHz steps

SymRate

BerRate

2.000-45.000 kSps symbol rate

<1.0 e-4The BER is an indication of the number of transmission errors and thus of the signal quality.<1.0 e-4 = very low numbers of errors1.0 e-3 = low number of errors1.0 e-2 = threshold for display: Signal? bad signal41.25 Mb = Input data rate

Sat-IF 950-2150 MHz Selection of Sat-IF, 1 MHz steps

SymRate

BerRate

2.000-45.000 kSps symbol rate

<1.0 e-4The BER is an indication of the number of transmission errors and thus of the signal quality.<1.0 e-4 = very low numbers of errors1.0 e-3 = low number of errors1.0 e-2 = threshold for display: Signal? bad signal41.25 Mb = Input data rate

DVBmode S QPSK - 1/2, 2/3, 3/4, 5/6, 7/8S2 8QPSK - 3/5, 2/3, 3/4, 5/6, 8/9, 9/10S2 QPSK - 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10

Pilot on / off

DVB-S2 module settings

GB

Settings DVB-S (Key code 1XXX)

Settings DVB-S2 (Key code 3XXX)

Input modules

Page 28: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 28 -

BerRate <1.0 e-4The BER is an indication of the number of transmission errors and thus of the signal quality.<1.0 e-4 = very low numbers of errors1.0 e-3 = low number of errors1.0 e-2 = threshold for display: Signal? bad signal14.46 Mb = Input data rate

In-Freq 146-858 MHz Selection of input frequency, 0.25 MHz steps

In-Offs Input offset-166 kHz, 0, +166 kHz @ 8 MHz-125 kHz, 0, +125 kHz @ 7 MHz

In-BW Bandwidth 7 / 8 MHz

HierMod Hierarch mode (available from "ModVers: H2.000)high (Priority)low (Priority)

In-ATT 0 dB, 20 dB input attenuator (available from "ModVers: H2.000)

DVB-T frontend module settings

GB

Channel overload, insert selective channel filter into RF input signal

BerRate <1.0 e-4The BER is an indication of the number of transmission errors and thus of the signal quality.<1.0 e-4 = very low numbers of errors1.0 e-3 = low number of errors1.0 e-2 = threshold for display: Signal? bad signal38.15 Mb = Input data rate

In-Freq 50-862 MHz Selection of input frequency, 0.5 MHz steps

SymRate 1750-7125 kSps input symbol rate

In-ATT 0 dB, 20 dB input attenuator

In-Mode 16, 32, 64, 128, 256 QAM

DVB-C frontend module settings

Settings DVB-T (Key code 4XXX)

Settings DVB-C (Key code 5XXX)

Page 29: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 29 -

VidRate 3,0: 4,5; 6,0; 9,0 Mbit/s output videodatarate

A-Mode Stereo, JointSt, Dual, Single

Name Programme name 7 digits

Provid. Provider name 7 digits

TP-Gen on / off blue screen

TSID Transport Stream Identifier; settings in HEX code 0 x FFFF

SID Service Identifier; settings in HEX code 0 x FFFF

VidNorm PAL, NTSC, SECAM; Video norm selection

Encode Aud/Vid = stored in TV list of the cable receiverAudio = stored in Radio list of the cable receiver - encoding of the audio signal

ASV frontend module settings

Settings AV-MPEG (Key code 6XXX)

GB

Settings ASI in/out (Key code 7XXX)

ASI loop

ASI frontend module settings

on / the ASI module is set in between Frontend and QAM modulator (ch A). Ch B is set to "off"off

A B

DVB-S ASI

Descrambler

A=on

QAMB=off

Ex: ASI loop: on

Note: Do not use same HEX address twice.OV 75 M 6641 with 2 AV front-end modulesSID mode: set Service identifier in HEXe.g. AV modul 1 HEX 0x002F AV modul 2 HEX 0x003F

Page 30: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 30 -

Settings IP 100 Mb (Key code 9XXX)

IPAddr 0 172 Move cursor under digit and select with Set IP address

29 Set IP address

1 Set IP address

Port 0-65535 Set Port address

91 Set IP address

IPAddr 1

IPAddr 2

IPAddr 3

MCAddr 0

MCAddr 1

MCAddr 2

MCAddr 3

MACAddr. 00039800000E - display MAC address0.9905 - display FPGA version

MCast

239 Move cursor under digit and select with Set Multicast address

255 Set Multicast address

off/on Multicast on/off

172 - the "address 0-3" to be selected is displayed on top172. 291. 91

255 Set Multicast address

255 Set Multicast address

ARPTime Menue is displayed when Multicast is set to off. ARPTime: off / adjustable from 2 to 255s.

IP frontend module settings

Page 31: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 31 -

Settings SDI-MPEG (Key code AXXX)

VidRate 3,0: 4,5; 6,0; 9,0 Mbit/s output videodatarate

A-Mode Stereo, JointSt, Dual, Single

Name Programme name 7 digits

Provid. Provider name 7 digits

TP-Gen on / off blue screen

TSID Transport Stream Identifier; settings in HEX code 0 x FFFF

SID Service Identifier; settings in HEX code 0 x FFFF

Encode Aud/Vid = stored in TV list of the cable receiverAudio = stored in Radio list of the cable receiver encoding of the audio signal

Aud-Grp analogue, 7/8; 5/6; 3/4; 1/2 selection of the audio group

Aud-Vol -18 ... +18 dB in 6 dB steps

SDI frontend module settings

Note: Do nut use HEX address twice

Page 32: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 32 -

Eingang / InputSiehe Eingangsmodule / Refer to input modules QAM modulatorAusgangskanalbandbreite / Output channel bandwidth 8 MHz(abhängig von der QAM-Symbolrate / depends on QAM symbolrate)Ausgangspegel / Output level loop (16-128 QAM) 64–74 dBµV (256 QAM) 70–80 dBµV

single (16-128 QAM) 74–84 dBµV (256 QAM) 80–90 dBµVAusgangspegelsteller / Output level 1 dB steps 0-10 dBModulation / Modulation type 16-, 32-, 64-, 128-, 256-QAMSymbolrate / Symbol rate 1,0–7,499 MS/sMER gemessen bei 256 QAM / measurement conditions 256 QAM typ. 42 dBFiltering Nyquist √ cosRoll-off 15 %Fehlercode / FEC outer code RS (204,188,16)Spectral inversion normal/invertedInterleaving Conv., I=12Nebenaussendungen / Spurious emissions

-innerhalb TV-Kanäle / inside TV-channels > 50 dB-ausserhalb eines TV-Kanals / outside a TV-channel > 50 dB

COFDM modulatorOutput channel bandwidth 5, 6, 7, 8 MHzOutput level loop 58 – 74 dBµV single 68 – 84 dBµVOutput attenuation 1 dB steps 0-16 dBModulation QPSK, QAM 16, QAM 64MER > 36 dBFEC 1/2, 2/3, 3/4, 5/6, 7/8Guard interval 1/4, 1/8, 1/16, 1/32FFT mode 2k, 8kShoulder attenuation > 50 dB Standard compliance- ETSI EN 300744 V1.51 Digital Video Broadcasting (DVB); Framing structure, channel coding and modulation for digital terrestrial television

Ausgang / OutputAusgangsimpedanz / Output impedance 75 OhmAusgangsfrequenz / Output frequency (ch A) 45 –862 MHzAbstimmschritte / Output frequency steps (ch A) 250 kHzKanalabstand A-B / Offset (ch A - B) 1 MHz steps 4–8 MHz nur bei Dual-QAM / only in Dual QAM modeRückflußdämpfung / Return loss > 14 dB

Technische Daten Dual-QAM Modul / Specifications Dual-QAM module

Page 33: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 33 -

Technische Daten REMUX-QAM Modul / Specifications REMUX-QAM module

Eingang / InputSiehe Eingangsmodule / Refer to input modules QAM-Ausgang / QAM outputAusgangsimpedanz / Output impedance 75 OhmAusgangsfrequenz / Output frequency (ch A) 45–862 MHzAbstimmschritte / Output frequency steps (ch A) 250 kHzBandbreite / Bandwidth (abhängig von der QAM-Symbolrate / depends on QAM symbolrate)Ausgangspegel / Output level loop (16-128 QAM) 64–74 dBµV (256 QAM) 70–80 dBµV

single (16-128 QAM) 74–84 dBµV (256 QAM) 80–90 dBµVAusgangspegelsteller / Output level 10 dB- Einstellschritte / Output level steps 1 dBRückflußdämpfung / Return loss > 14 dBModulation / Modulation type 16-, 32-, 64-, 128-, 256-QAMSymbolrate / Symbol rate 1,0–7,499 MS/sMER gemessen bei 256 QAM / measurement conditions 256 QAM typ. 43 dBFiltering Nyquist √ cosRoll-off 15 %Fehlercode / FEC outer code RS (204,188)Spectral inversion normal/invertedInterleaving Conv., I=12Nebenaussendungen / Spurious emissions (45-862 MHz) > 50 dB Ausgang / OutputAusgangsimpedanz / Output impedance 75 OhmAusgangsfrequenz / Output frequency (ch A) 45 –862 MHzAbstimmschritte / Output frequency steps (ch A) 250 kHzRückflußdämpfung / Return loss > 14 dB

Page 34: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 34 -

QPSK-Eingang / InputEingangsimpedanz / Input impedance 75 OhmEingangsfrequenz / Input frequency 950–2150 MHzAbstimmschritte / Input frequency steps 1 MHzEingangspegel / Input level 44-84 dBµVModulationsart / Type of modulation QPSKFehlerkorrektur / FEC 1/2, 2/3, 3/4, 5/6, 7/8Symbolrate / Symbol rate 2–45 MS/sTransportstrom-Ausgang / Transport stream output

Technische Daten DVB-S Modul / Specifications DVB-S module

QPSK-Eingang / InputEingangsimpedanz / Input impedance 75 OhmEingangsfrequenz / Input frequency 950–2150 MHzAbstimmschritte / Input frequency steps 1 MHzEingangspegel / Input level 47-70 dBµVModulationsart / Type of modulation DVB-S QPSK DVB-S2 QPSK / 8 QPSKFehlerkorrektur / FEC DVB-S 1/2, 2/3, 3/4, 5/6, 7/8 DVB-S2 1/4, 1/3, 2/5, 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10Symbolrate / Symbol rate DVB-S 2–45 MS/s DVB-S2 10-30 MS/sTransportstrom-Ausgang / Transport stream output

Technische Daten DVB-S2 Modul / Specifications DVB-S2 module

DVB-T-Eingang / InputEingangsimpedanz / Input impedance 75 OhmEingangsfrequenz / Input frequency 146–858 MHzAbstimmschritte / Input frequency steps 0,25 MHzBandbreite / Bandwidth 7 / 8 MHzFrequenz-Offset / Frequency offset 8 MHz + 166 kHz 7 MHz + 125 kHz

Eingangspegel / Input level 40-90 dBµV

Modulationsart / Type of modulation QPSK, 16, 64 QAM

COFDM 2k-FFT, 8k-FFT

Guard intervall 1/4, 1/8, 1/16, 1/32

Fehlerkorrektur / FEC 1/2, 2/3, 3/4, 5/6, 7/8Transportstrom-Ausgang / Transport stream output

Technische Daten DVB-T Modul / Specifications DVB-T module

Page 35: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 35 -

Video-Eingang / Video inputEingangsimpedanz / Input impedance 75 OhmEingangsformat / Input format Composite PALEingangspegel / Input level 1 VppEncoder-Standard / Encoding Standard ISO / IEC 13818-2 MP@ML (4:2:0)Bitrate / Bit rate 1,5 Mbit/s-9 Mbit/sUnterstützte Auflösung / Supported resolutions Full D1Betriebsart / Operation mode CBR, VBR

Audio-Eingang / Audio inputEingangsformat / Input format Analog (left, right) 83-9Eingangspegel / Input level 0 dBm / 600 OhmAbtastrate / Sampling frequency 48 kHzEncoder-Standard / Encoding Standard MPEG1 Layer 2 Bitrate / Bit rate 192 kbit/sEntzerrung / Emphasis noneBetriebsart / Mode stereo, join stereo, dual, single channel

Technische Daten AV Modul / Specifications AV module

Eingang / InputEingangsimpedanz / Input impedance 75 OhmEingangsfrequenz / Input frequency 50–862 MHzAbstimmschritte / Input frequency steps 0,5 MHzEingangspegel / Input level 45-90 dBµV - Dämpfungssteller auf 20 dB geschaltet / Attenuator set to 20 dB 65-110 dBµVEingangsdämpfungssteller schaltbar / Input signal attenuator 0 dB / 20 dBModulationsart / Type of modulation 16, 32, 64, 128, 256-QAMSymbolrate / Symbol rate 1.75–7.125 MS/sTransportstrom-Ausgang / Transport stream output

Technische Daten DVB-C Modul / Specifications DVB-C module

Page 36: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 36 -

ASI-TransmitterLVTTL - Eingang / LVTTL inputDatenformat / Data format DVB-SPI (LVTTL), EN50083-9Packete / Packet framing 188 / 204 byte per packet

ASI-Ausgang / ASI outputDatenformat / Data format DVB A010 ASI-C, EN50083-9Packete / Packet framing 188 / 204 byte per packetBitrate 270 Mb/sASI-Betriebsart / ASI mode BurstSignalpegel / Signal level 800mV (p-p)Deterministic jitter 10%

ASI-Eingang / ASI inputEingangsimpedanz / Input impedance 75 OhmDatenformat / Data format DVB A010 ASI-C, EN50083-9Bitrate 270 Mb/sASI-Betriebsart / ASI mode Burst or continuousPackete / Packet framing 188 / 204 byte per packetEmpfindlichkeit / Sensitivity 200mV (p-p)Max. Signalpegel / Max. signal level 880mV(p-p)Eingangs-Rückflussdämpfung / Input return loss > 17 dB (27-270 MHz)

LVTTL-Ausgang / outputDatenformat / Data format DVB-SPI (LVTTL), EN50083-9Packete / Packet framing 188 / 204 byte per packet

Technische Daten ASI-Modul / Specifications ASI module

Technische Daten IP-Modul / Specifications IP module

Ethernet-Eingang / Ethernet inputInterface 10/100 Base (RJ45)Frame Format Ethernet IIRate 10/100 Mbps autosensingProtokoll / Protocol UDP/IP, ARP, ICMP(ping), IGMPv2Ethernet Übertragung / Ethernet tansmitting Unicast, Multicast

Page 37: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 37 -

Technische Daten SDI-Modul / Specifications SDI module

Video-Eingang / Video inputEingangsformat / Input format SDI SMPTE 259M-C 270Mb/s 625Z with embedded audio SMPTE 272M-AEingangspegel / Input level 200 mVpp ohne / without equalizerEingangsimpedanz / Input impedance 75 OhmEncodingstandard / Encoding standard MPEG 2 ISO/IEC 13818-2 MP@ML (4:2:0)Bitrate / Bit rate 1,5 Mbit/s up to 9 Mbit/sUnterstütze Auflösungen / Supported resolutions Full D1Bildgröße / Frame format horizontal/vertical 720/576 pixel

Audio-Eingang / Audio inputEingangsformat / Input format Analog (left,right) or digital (SDI with embedded Audio)Eingangspegel / Input level 0 dBm / 600 OhmEncodingstandard / Encoding standard MPEG 1 L1/2 ISO/IEC 13818-3Bitrate / Bit rate up to 192 kbit/sEmphasis keine / noneAudiomode stereo, joint stereo, dual, singleAbtastfrequenz / Sampling frequency 48 kHz

Transportstrom-Ausgang / Transport stream outputStream type MPEG 2 transport streamElementary streams Video. Audio,System multiplexing ISO/IEC 13818-1Tabellen / Tables PAT, PMTSystem Bitrate / System bit rate 1,6875 … 13,5 MB/sBetriebsart / Operation mode CBR, VBR

Allgemeines / GeneralGehäuse / Housing Zinkdruckguss / Zinc die-castAbmessungen / Dimensions 30 x 260 x 200 mmAnschlüsse / Sockets HF-Ein-Ausgang / RF input and output F-typeBetriebsspannung / Operating voltage 5,2 VDC / 1350 mA max.* 12,5 VDC / 400 mA max.*Betriebstemperaturbereich / Operating temperatur range 0°C ... +50°CLagertemperatur / Storage temperatur -25°C ...+75°CMax. Luftfeuchte, nicht kondensierend / Max. humidity, non condensing 95%EMV / EMC EN 50083-2 *je nach Konfigu-

rationdep. on config

Page 38: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 38 -

Beispiel / ExampleOV 75 M 11 21 = 2 x DVB-S Dual-QAMOV 75 M 44 11 = 2 x DVB-T Remux-QAMOV 75 M 47 11 = DVB-T / ASI Remux-QAMOV 75 M 66 41 = 2x AV-Encoder Remux-COFDMOV 75 M 40 41 = DVB-T-COFDM Repeater

0 - n.a.1 - DVB-S 2 - n.a.3 - DVB-S2 4 - DVB-T 5 - DVB-C 6 - AV-MPEG 7 - ASI - Input/Output 8 - n.a.9 - Ethernet - Input (IP)A - SDI - MPEG

1 - Remux QAM

2 - Dual QAM (with transportstream handling*)

3 - Dual QAM (without transportstream handling)

4 - Remux COFDM

O V 7 5 M x x x 1

KanalschlüsselKey code

Ausgang Output

Eingang Input 1 2

Option 1

Bestellinformationen / Ordering informations

keine Anwendung fürno application:2 x DVB-S2

Hinweis: *SI table editor mit CS 76 (separat bestellen)!!Note: SI table editor with CS 76 (Order separately)

Bestellbeispiele / Ordering samples

Remux QAMEingangsmodule slot 1/2 Input modules slot 1/2

7111 ASI In,Out / DVB-S 7611 ASI In,Out / AV-MPEG7711 ASI In,Out / ASI In/Out6611 AV-MPEG / AV-MPEG

5311 DVB-C / DVB-S25511 DVB-C / DVB-C 5611 DVB-C / AV-MPEG

1111 DVB-S / DVB-S1411 DVB-S / DVB-T1611 DVB-S / AV-MPEG1711 DVB-S / ASI In/Out

3011 DVB-S2 / —3111 DVB-S2 / DVB-S3711 DVB-S2 / ASI In/Out

Dual QAM + NITEingangsmodule slot 1/2 Input modules slot 1/2

7021 ASI In,Out / —

6621 AV-MPEG / AV-MPEG

6721 AV-MPEG / ASI In/Out

7621 ASI In/Out / AV-MPEG7721 ASI In,Out / ASI In/Out

5021 DVB-C / —

5521 DVB-C / DVB-C5721 DVB-C / ASI In,Out

1021 DVB-S / —1121 DVB-S / DVB-S1321 DVB-S / DVB-S21421 DVB-S / DVB-T1721 DVB-S / ASI In/Out

3021 DVB-S2 / —3721 DVB-S2 / ASI In/Out

4411 DVB-T / DVB-T4511 DVB-T / DVB-C 4611

9511 Ethernet In (IP) / DVB-C

Page 39: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 39 -

Dual QAM ohne / without NITEingangsmodule slot 1/2 Input modules slot 1/2

7731 ASI In,Out / ASI In/Out

1131 DVB-S / DVB-S

3031 DVB-S2 / —

Remux COFDMEingangsmodule slot 1/2 Input modules slot 1/2

7041 ASI In/Out / —

7741 ASI In,Out / ASI In,Out

9741 Ethernet In (IP) / ASI In, Out 1041 DVB-S / — 1141 DVB-S / DVB-S

3141 DVB-S2 / DVB-S

4041 DVB-T / — (COFDM Repeater) 4441 DVB-T / DVB-T

AA41 SDI / SDI

4021 DVB-T / —4421 DVB-T / DVB-T4721 DVB-T / ASI In,Out

9121 Ethernet In (IP) / DVB-S9421 Ethernet In (IP) / DVB-T9721 Ethernet In (IP) / ASI In, Out9921 Ethernet In (IP) / Ethernet In (IP)

Blockdarstellung / Block diagram

DVB - SDVB - S2DVB - TASIIPAVSDI

DVB - SDVB - S2DVB - TASIIPAVSDI

QAMModulator

*

*

QAMModulator

IFRF

DVB - SDVB - S2DVB - TASIIPAVSDI

DVB - SDVB - S2DVB - TASIIPAVSDI

Multiplexer

*

*

QAMor

COFDMModulator

IFRT

*Required front end:please specify with your order

*Required front end:please specify with your order.1xDVB-T input module is required for Repeater mode.Note: 2x DVB-S2 - no application

Page 40: OV 75M Grundmodul / Basic module statically Remultiplexer ...€¦ · Factory settings 1 Block diagram 40 Operation basic modules - Connections 2 - Dual QAM 18 - REMUX 19 - COFDM

- 40 -

11/ 0

8

WISI Communications GmbH & Co. KGEmpfangs- und VerteiltechnikWilhelm-Sihn-Straße 5-7, 75223 Niefern-ÖschelbronnTel . 07233 / 66-0, Fax. 66-320, http://www.wisi.de

Technische Änderungen und Druckfehler vorbehalten!Technical Modifications reserved. WISI cannot be held liable for any printing error.