IBJ-QUALITY CONTROL LABORATORY 1
Overall Quality Testing Methods and Analysis
PREPARED BY: MITUL TEWAR
IBJ-QUALITY CONTROL LABORATORY 2
INTRODUCTION Importance Of Quality Control Types of Samples Test Parameters Spec For Samples Reference Standards Hazards & Safety
IBJ-QUALITY CONTROL LABORATORY 3
Importance Of Quality Control Maintain Quality of product throughout process. Prevent the Defect or Contamination during the process. Prevent Product rejection from the customer. Reduce the cost of Reprocess the sample. Quality Control Data useful for process improvement.
IBJ-QUALITY CONTROL LABORATORY 4
Types of SamplesWater Samples Gas Samples CS2 Sulfur MDEA1. BOILER2. CIRCULATING3. COOLING TOWER4. STP5. GIDC6. DM / DE OXIDE7. CONDENSET8. +7 & -35°
1. ACID GAS2. PROCESS GAS3. TAIL GAS4. NATURAL GAS
1. 265 IP 3842. IV 501 A/B/C3. IV 502 A/B4. Tanker
1. Solid sulfur 1. V 3012. P 301
IBJ-QUALITY CONTROL LABORATORY 5
Test ParametersWater Samples Gas Samples CS2 Sulfur MDEA1. pH2. CONDUCTIVITY3. TDS4. P -ALK AND T- ALK5. CHLORIDE6. PO47. TURBIDITY8. HARDNESS9. IRON
1. Qualitative 2. Quantitative analysis
1. SPGR2. DISTILLATION RANGE3. NVM4. IODINE REDUCING SULFUR
1. MOISTURE2. ASH3. ACIDITY4. PURITY
1. % OF MDEA2. H2S CONTENT
IBJ-QUALITY CONTROL LABORATORY 6
Spec For SamplesWATER SAMPLES
PARAMETER BOILER DM / DE OXIDE CIRCULATING CONDENSET +7 & -35 GIDC STP
pH 10 -12 7.5 -8.5 7.0 -8.5 10 -12 7.0 – 9.0 7 – 8.5 7 – 8.5
P-Alk ≤ 5 mmol/L - - ≤ 6 mmol/L - - -
T-Alk ≤ 8 mmol/L - - ≤ 10 mmol/L - - -
Chloride ≤ 300 mg/L - - - - - -
Hardness - ≤ 0.03mmol/L ≤ 50mmol/L ≤ 0.1 mmol/L - - -
Conductivity ≤ 20μS/cm ≤ 15μS/cm - ≤ 50μS/cm - 350 -
TDS - - - - - 150 -
Turbidity - ≤ 1 NTU - - -
IBJ-QUALITY CONTROL LABORATORY 7
Spec For SamplesGAS SAMPLES
PARAMETER ACID GAS PROCESS GAS NATURAL GAS TAIL GAS
H2S 90 – 95% 4 - 8% - 1.0 -2.0 %
SO2 - 0 - 4% - NIL
H2S/SO2 - 1.8 - 2.2 - -
CH4 0 - 3% - 95 – 98% -
CS2 0 - 3% - - -
N2 0 - 3% - - 90 - 95 %COS - - - -
CO2 - - - 1.5 - 2.5 %
H2 - - - 2.0 -4.0 %
IBJ-QUALITY CONTROL LABORATORY 8
Spec For SamplesCS2 SAMPLES
PARAMETER High Class First Class Confermity Class
SPGR 1.262~1.265 1.262~1.267 1.262~1.267DIST. RANGE (45.6~46.6°C),101.32 Pa
98.00%≥ 97.00% 96.00%
% NVM 0.001 0.007 0.01
IODINE REDUCING SULFUR 0.0002 0.0005 0.0008
SULFUR AND SULFIDES Pass Pass Pass
IBJ-QUALITY CONTROL LABORATORY 9
Spec For SamplesSULFUR & MDEA SAMPLES
PARAMETER SULFUR PARAMETER MDEA
Moisture ≤ 0.1% % of MDEA 30 - 32 %Ash ≤ 0.03% H2S content < 1 g/L
Acidity ≤ 0.003%
Purity 99.90% ≤
IBJ-QUALITY CONTROL LABORATORY 10
Reference Standards Chinese Laboratory Manual.
Indian Standards (IS)
Certified Standard Gas Mixtures.
NIST traceable pH Buffers.
IBJ-QUALITY CONTROL LABORATORY 11
Safety Precautions Use H2S cartridge mask during Acid and Process gas Sampling.
Use concentrated NaOH slurry for flushing out of all those gases which may contain H2S.
Take H2S Detector during plant side sampling, specially for Acid and Process gas sampling.
Wear heat resistance hand gloves and goggle during Boiler water sampling.
Always cut the sample gas bag first before discard it in predefine area.
Strictly follow the SOPs for discarding sample gas bags, chemicals and laboratory used items.
IBJ-QUALITY CONTROL LABORATORY 12
THANK YOU….