PROFESSIONAL INSECT LIGHT TRAPS OWNER'S MANUAL INSTALLATION • OPERATION • PARTS For Models: 711, 601T, 601TJ, 601E, 601C, 220, 607, 705, 605 2000GT, 2002GT, 1999GT, 2004GT, 2012GT, 225GT, 601GT, 219GT, 747GT CAUTION: All Repairs Must Be Performed By Qualified Personnel READ THIS FIRST Before use, inspect the unit for in transit damage. Report any dam- age to the delivering carrier for immediate "claim for damage" to the unit. Before returning a unit for repair, notify your distributor or factory for return authorization. Do not discard the box or packing material until you are certain the unit is in good working order. Once installed, if trap does not light. make sure the safety actua- tor switch is engaged by either closing the guard or securing the tray, depending on the particular model. All electrocuting light traps have one such safety switch. If lamp flickers, try reversing lamp(s). Gilbert Industries, Inc. 5611 Krueger Drive, Jonesboro, Arkansas 72401 TOLL-FREE SERVICE PHONE (800)643-0400 PHONE: 870-932-6070 FAX: 870-932-5609 WEBSITE: www.gilbertinc.com ® 6999 #312 Printed with Soy Ink on Recycled Paper LIMITED 1 YEAR WARRANTY LIMITED 5 YEAR WARRANTY To the original purchaser of this new Gilbert® 230 volt or Flying Venus™ Wall Sconce/Fly Traps, we warrant that we will replace or repair free of charge any part found by us to be defective in factory workmanship or material for a period of one year from date of purchase. This replacement or repair of defective parts shall constitute the sole and exclusive remedy of the original purchaser. THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRAN- TIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS, AND OF ANY OTHER OBLIGATION ON THE PART OF GILBERT INDUSTRIES, INC. IN NO EVENT SHALL GILBERT INDUS- TRIES, INC. BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, nor for damage due to accident, abuse, lack of reasonable care, normal wear, unauthorized repair or operation on a power source other than that specified. The provisions of this warranty shall be governed by and construed under the laws of the state of Arkansas. To the original purchaser of a new Gilbert® Insect Light Trap (except 230 volt units or the Flying Venus™), we warrant that we will replace or repair free of charge any part found by us to be defective in factory workmanship or material for a period of five years from date of purchase. This replacement or repair of defective parts shall constitute the sole and exclusive remedy of the original purchaser. THE FOREGOING WAR- RANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS, AND OF ANY OTHER OBLIGA- TION ON THE PART OF GILBERT INDUSTRIES, INC. IN NO EVENT SHALL GILBERT INDUSTRIES, INC. BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, nor for damage due to accident, abuse, lack of reasonable care, normal wear, unauthorized repair or operation on a power source other than 120 volt, 60 Hertz. The provisions of this warranty shall be governed by and construed under the laws of the state of Arkansas. Gilbert Hg - LAMPS CONTAIN MERCURY MANAGE IN ACCORD WITH DISPOSAL LAWS See: www.lamprecycle.org or 1- 800-643-0400

Upload: others

Post on 15-Mar-2020

15 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: OWNER'S MANUAL - Gilbert Industries, Inc. · OWNER'S MANUAL INSTALLATION • OPERATION • PARTS For Models: 711, 601T, 601TJ, 601E, 601C, 220, 607, 705, 605 2000GT, 2002GT, 1999GT,

PROFESSIONALINSECT LIGHT TRAPS

OWNER'S MANUALINSTALLATION • OPERATION • PARTS

For Models: 711, 601T, 601TJ, 601E, 601C, 220, 607, 705, 6052000GT, 2002GT, 1999GT, 2004GT, 2012GT, 225GT, 601GT, 219GT, 747GT

CAUTION: All Repairs Must Be Performed By Qualified Personnel

READ THIS FIRSTBefore use, inspect the unit for in transit damage. Report any dam-age to the delivering carrier for immediate "claim for damage" to the unit. Before returning a unit for repair, notify your distributor or factory for return authorization. Do not discard the box or packing material until you are certain the unit is in good working order.

Once installed, if trap does not light. make sure the safety actua-tor switch is engaged by either closing the guard or securing the tray, depending on the particular model. All electrocuting light traps have one such safety switch. If lamp flickers, try reversing lamp(s).

Gilbert Industries, Inc.5611 Krueger Drive, Jonesboro, Arkansas 72401

TOLL-FREE SERVICE PHONE (800)643-0400PHONE: 870-932-6070 FAX: 870-932-5609 WEBSITE: www.gilbertinc.com

®

6999 #312 Printed with Soy Ink on Recycled Paper

LIMITED 1 YEAR WARRANTYLIMITED 5 YEAR WARRANTYTo the original purchaser of this new Gilbert® 230 volt or Flying Venus™ Wall Sconce/Fly Traps, we warrant that we will replace or repair free of charge any part found by us to be defective in factory workmanship or material for a period of one year from date of purchase. This replacement or repair of defective parts shall constitute the sole and exclusive remedy of the original purchaser. THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRAN-TIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS, AND OF ANY OTHER OBLIGATION ON THE PART OF GILBERT INDUSTRIES, INC. IN NO EVENT SHALL GILBERT INDUS-TRIES, INC. BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, nor for damage due to accident, abuse, lack of reasonable care, normal wear, unauthorized repair or operation on a power source other than that specified. The provisions of this warranty shall be governed by and construed under the laws of the state of Arkansas.

To the original purchaser of a new Gilbert® Insect Light Trap (except 230 volt units or the Flying Venus™), we warrant that we will replace or repair free of charge any part found by us to be defective in factory workmanship or material for a period of five years from date of purchase. This replacement or repair of defective parts shall constitute the sole and exclusive remedy of the original purchaser. THE FOREGOING WAR-RANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS, AND OF ANY OTHER OBLIGA-TION ON THE PART OF GILBERT INDUSTRIES, INC. IN NO EVENT SHALL GILBERT INDUSTRIES, INC. BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, nor for damage due to accident, abuse, lack of reasonable care, normal wear, unauthorized repair or operation on a power source other than 120 volt, 60 Hertz. The provisions of this warranty shall be governed by and construed under the laws of the state of Arkansas.

Gilbert

Hg - LAMPS CONTAIN MERCURYMANAGE IN ACCORD WITH DISPOSAL LAWS

See: www.lamprecycle.org or 1- 800-643-0400

Page 2: OWNER'S MANUAL - Gilbert Industries, Inc. · OWNER'S MANUAL INSTALLATION • OPERATION • PARTS For Models: 711, 601T, 601TJ, 601E, 601C, 220, 607, 705, 605 2000GT, 2002GT, 1999GT,

2

CAUTION

CAUTION

SAFETY INSTRUCTIONS

Do not insert foreign objects into this product. Extension cords are available and devices for retaining an extension cord connection to the power supply cord are also available through your local electri-cal supply house. Use extension cord marked SJW-A, SJEW-A, or SJTW-A only. Use only extension cords which have plugs and receptacles which accept the product's plug. Replace or repair dam-aged cords. The electrical rating of the extension cord must be as great as the electrical rating of the product. Don't abuse cord--never carry product by cord or yank it to disconnect from receptacle. Keep cord from heat, oil, and sharp edges. Disconnect the product from the power supply when not in use, before servicing, when changing lamps, cleaning and the like.

All repairs and maintenance must be performed by qualified personnel. Removal of insects and user maintenance such as relamping may be performed by user.

Do not use any electric flytraps in explosion sensitive areas. See National Electric Code.

Remove all packing material (paper, etc.) from unit BEFORE connecting to power. Packing materials left in unit could result in fire.

Switch off power before servicing. Primary circuits are 120 volt, 60HZ and secondary grid voltage is 4500 volts at 9.8MA max.

Do not defeat interlock. ATTENTION: Ne pas nuire a l'action du verrouillage de securite.

For commercial indoor use only. Device not constructed for use outdoors or in wet locations. To avoid risk of fire or electric shock, do not use where it may be exposed to water or direct sunlight, including roofed but open porches. Reserve pour usage commercial a l'interieur. Ce dispositif ne convient pas pour l'exterie ou les emplacements mouilles.

CAUTION

EXTERIOR FINISHGENERAL SPECIFICATIONS

Underwriters' Laboratories listed units display the U.L. trademarks and fully comply with standards established by O.S.H.A., U.S.D.A. and other inspection agencies.

All our flytraps are Canadian Standards Association approved. Units display C.S.A. label.Registered with the Environmental Protection Agency, EPA Est. 39032-AR-1.Each unit is equipped with the properly rated spectral energy lamp for maximum insect attractancy. Lamp replacement should be the same brand and number for optimum efficiency. New Shattercatch® coated lamps are available for areas where shatter proof lamps are required.

Anodized aluminum construction is standard (optional fin-ishes available on request). Models 601T and 601TJ are constructed entirely of aluminized steel.

• Frame and load carrying parts constructed of aluminized- steel. Model 220 is constructed of 100% aluminum for ligh weight portability.• 6 foot, 3 wire grounded power cord.• Operates from standard 115 volt, 60 Hertz power source at .52 to .84 amps. (38 to 93 watts).• Transformer Secondary is 4500 volts at 9.8MA max.• All transformers are high reactance, shunt-protected and true current limiting.

INTERIOR

FDA has measured ultraviolet radiation emission from a typical insect attracting device and has concluded that there is not a significant concern about acute health problems. The conclusion was based on Threshold Limit Values (TLV) of exposure as recommended by the American Conference on Governmental Industrial Hygienists (ACGIH) as presented and discussed by Phillips (1983). However, since it's scientifically impossible to rule out possible long-term exposure effects, on our own accord, as a precautionary measure, we suggest it might be prudent for operators to position these devices so that employees are not required to work continuously in close eye level proxim-ity, i.e. over a sink or table where an employee would be within one meter continuously. See: www.gilbertinc.com/lamps.htm

CAUTION

CAUTION

CAUTION

CAUTION

Page 3: OWNER'S MANUAL - Gilbert Industries, Inc. · OWNER'S MANUAL INSTALLATION • OPERATION • PARTS For Models: 711, 601T, 601TJ, 601E, 601C, 220, 607, 705, 605 2000GT, 2002GT, 1999GT,

GROUNDINGRECEPTACLE

Flying Insects are highly attracted to our trap designs and the lamps we have selected. Coupled with good integrated management procedures, Gilbert® traps provide unequaled flying insect control. And, a few even provide beauty and style.Good strategy emphasizes eliminating flies early, well before they get into the area(s) you most need to protect (i.e. kitchens, production areas, dining areas, etc.). When possible, find the source of the problem and deal with it. Dumpster control tactics, sanitation, physical exclusion, strategic lighting, employee education, the judicious use of approved chemicals, and Gilbert® traps are all part of a well integrated fly management program.Place the first traps at entrance(s), then bottlenecks. Spread traps out along the flyways from outside entrances (especially those near dumpsters) to the area(s) you need to protect. Be careful not to position traps too close to an entrance drawing an excess of insects inside. Window tinting film will screen out most UV and reduce night-fliers congregating on glass doorways.Light traps are more attractive to (finicky) flies when placed down low. Night fliers are more immediately responsive to traps (you've seen how insanely they are drawn to porch lights). Night fliers will go down to traps much more readily than flies will go up. Most traps should be placed down low, the lower the better. See: gilbertinc.com/strategic.htm.Consider ADA (American Disabilities Act) when installing traps (See: gilbertinc.com/ada.htm)

All units are equipped with 3-wire grounding plug and to reduce the risk of an electric shock should be plugged into an appropriate outlet that is properly installed and grounded. Consult a qualified electrician or serviceman if the grounding instructions are not completely understood, or if doubt as to whether proper grounding exists.

Use only 3-wire extension cords which have 3-prong grounding type plugs and 3-pole receptacles which accept the product's plug. Replace or repair damaged cords.

Models: 711, 601T, 601E, 601C, 607, 705SCHEMATICS--ELECTRICAL CIRCUITS

Model: 747GT

Models1999GT, 2000GT, 2002GT, 2004GT, 2012GT, 225GT,

601GT, 219GT

Models; 601TJ, 220

MAINTENANCE1. Empty and clean catch trays (or replace glueboards) fre-quently. Cultures may result from leaving dead insects in the unit. Clean bi-weekly or at least as often as local codes require. 2. Disconnect power and wash the lamps and inner-body with a warm soapy solution and rinse as needed. Clean the grid section of electrocuters with a stiff brush. All exterior finishes require cleaning and care to maintain their original luster.

Never clean brass surface with ammonia cleaner to avoid removing protective lacquer.3. Replace lamps/glueboards regularly: gilbertinc.com/lamprep.htm. See also: gilbertinc.com/glueboard.htm

Hg - LAMPS CONTAIN MERCURYMANAGE IN ACCORD WITH DISPOSAL LAWS

See: www.lamprecycle.org or 1- 800-643-0400

3

STRATEGIC INSTALLATION

Model: 605

Page 4: OWNER'S MANUAL - Gilbert Industries, Inc. · OWNER'S MANUAL INSTALLATION • OPERATION • PARTS For Models: 711, 601T, 601TJ, 601E, 601C, 220, 607, 705, 605 2000GT, 2002GT, 1999GT,

4528-S(2)

4530-S(2)

Models 601T Don™, 601E Executive™ & 601TJ Junior™INSTALLATION INSTRUCTIONS1. LAMPS SHOULD BE IN A VERTICAL POSITION WHEN UNIT IS PROP-ERLY INSTALLED.2. FOR FLAT-WALL MOUNTING: USING A LEVEL AND PENCIL, DRAW A STRAIGHT 7" LINE APPROX. 5' ABOVE FLOOR. COME IN 1/4" FROM ONE END AND MARK ACROSS THAT LINE. MEASURE 5 1/4" FROM THAT POINT AND MAKE A SECOND MARK. MOUNT THE TWO SCREWS (PROVIDED) AT THE CROSSPOINTS, LEAVING 1/2" OF THE SCREW STICKING OUT. SLIDE UNIT ONTO MOUNTING SCREWS AND CONNECT TO AC POWER. 3. FOR CORNER MOUNTING: USING A LEVEL AND PENCIL, DRAW A STRAIGHT 8 1/2" LINE FROM THE CORNER IN BOTH DIRECTIONS, AP-PROX. 5' ABOVE FLOOR. MAKE A CROSS MARK AT THE END OF BOTH LINES. MOUNT THE TWO SCREWS (PROVIDED) AT THE CROSSPOINTS, LEAVING 1/2" OF THE SCREW STICKING OUT. SLIDE UNIT ONTO MOUNT-ING SCREWS AND CONNECT TO AC POWER.4. AFTER MOUNTING UNIT, OPEN THE GUARD AND PUT THE 2 ADDI-TIONAL SCREWS (PROVIDED) IN THE 2 SLOTS AT THE BOTTOM.5. MODELS 601E & 601C (ONLY) MAY BE RECESS MOUNTED IN WALL.NOTE: IF MOUNTING ON MASONRY, USE A 3/16" BIT (NOT PROVIDED) AND DRILL OUT THE TWO CROSS MARKS AND INSERT THE TWO PLAS-TIC ANCHORS (PROVIDED) BEFORE MOUNTING THE TWO SCREWS.

The Don™, Executive™ and Junior™ are for use indoors to control flies and other flying insects. These models have key-hole slots located on the back for wall or corner installation and should be mounted 6" to 12" above floor for best results.

To recess mount the Executive™, remove wing nut at bottom of inner body (which contains all electrical components), pull out bottom of inner body, slide down and out. Mount outer case permanently into wall. Reverse process to insert inner body.

INSTALLATION INSTRUCTIONS

1. LAMPS SHOULD BE IN A HORIZONTAL POSITION WHEN UNIT IS PROP-ERLY INSTALLED.

2. USING A LEVEL AND PENCIL, DRAW A STRAIGHT 33" LINE APPROX. 3' ABOVE FLOOR. COME IN 1/4" FROM ONE END AND MARK ACROSS THAT LINE. MEASURE 32" FROM THAT POINT AND MAKE A SECOND MARK. MOUNT THE TWO SCREWS (PROVIDED) AT THE CROSSPOINTS, LEAV-ING 1/2" OF THE SCREW STICKING OUT. SLIDE UNIT ONTO MOUNTING SCREWS AND CONNECT TO AC POWER. NOTE: IF MOUNTING ON MASONRY, USE A 3/16" BIT (NOT PROVIDED) AND DRILL OUT THE TWO CROSS MARKS AND INSERT THE TWO PLASTIC ANCHORS (PROVIDED) BEFORE MOUNTING THE TWO SCREWS.

The Flying Lion™ is a superior trap to control flies and other flying insects. Keyhole slots are located on back for wall installation. Generally speaking, the lower any trap is placed, the more effective it is against flies. The Flying Lion™ is normally mounted 24" above the floor.

Model 711 Flying Lion™

4

MODEL: Gilbert® 711 "Flying Lion"

PROFESSIONAL ELECTROCUTING LIGHT TRAPS

INSTALLATION AND APPLICATIONREMOVE ALL PACKING MATERIALS BEFORE INSTALLATION

See Parts List (Page 16) For Part Descriptions

Page 5: OWNER'S MANUAL - Gilbert Industries, Inc. · OWNER'S MANUAL INSTALLATION • OPERATION • PARTS For Models: 711, 601T, 601TJ, 601E, 601C, 220, 607, 705, 605 2000GT, 2002GT, 1999GT,

4526 (4)

4539 (2)

4560 (2)

4538 (2)

4526(2)

5

MODEL: Gilbert® 601T "Don" MODEL: Gilbert® 601TJ "Junior"

MODEL: Gilbert® 601E "Executive"

See Parts List (Page 16) For Part Descriptions

Page 6: OWNER'S MANUAL - Gilbert Industries, Inc. · OWNER'S MANUAL INSTALLATION • OPERATION • PARTS For Models: 711, 601T, 601TJ, 601E, 601C, 220, 607, 705, 605 2000GT, 2002GT, 1999GT,

MODEL: Gilbert® 220 "Guerrilla"

WALL -MOUNTED CEILING-HUNGOR USED AS

LIGHTWEIGHT-PORTABLE

Model 220 Guerrilla™ - Multiple Applications:

INSTALLATION INSTRUCTIONS

1. THIS UNIT IS DESIGNED FOR INDOOR USE ONLY.

2. LAMPS SHOULD BE IN A HORIZONTAL POSITION WHEN UNIT IS PROPERLY INSTALLED.

3. SUSPEND BY CHAIN (NOT PROVIDED) 7 TO 10 FEET HIGH OR 6 INCHES ABOVE PRODUCT STOCK.

INSTALLATION INSTRUCTIONS

1. THIS UNIT IS DESIGNED FOR INDOOR USE ONLY.

2. LAMPS SHOULD ALWAYS BE IN A HORIZONTAL POSITION.

3. MAY BE USED WITH PROPER EXTENSION CORD FOR TEMPO-RARY SURVEILLANCE OR SPOT CONTROL (OVERNIGHT, FOR EX-AMPLE). MOST EFFECTIVE WHEN PLACED ON FLOOR IN MIDDLE OF TARGET AREA.

INSTALLATION INSTRUCTIONS

1.THIS UNIT IS DESIGNED FOR INDOOR USE ONLY.

2. LAMPS SHOULD BE IN A HORIZONTAL POSITION WHEN UNIT IS PROP-ERLY INSTALLED.

3. USING A LEVEL AND PENCIL, DRAW A SRAIGHT 28" LINE 24"-48" ABOVE FLOOR. COME IN 1/4" FROM ONE END AND MARK ACROSS THAT LINE. MEASURE 27" FROM THAT POINT AND MAKE A SECOND MARK. MOUNT THE TWO SCREWS (PROVIDED) AT THE CROSSPOINTS, LEAVING 1/2" OF THE SCREW STICKING OUT. SLIDE UNIT ONTO MOUNTING SCREWS AND CONNECT TO AC POWER. NOTE: IF MOUNTING ON MASONRY, USE A 3/16" BIT (NOT PROVIDED) AND DRILL OUT THE TWO CROSS MARKS AND INSERT THE TWO PLASTIC ANCHORS (PROVIDED) BEFORE MOUNTING THE TWO SCREWS.

6

PROFESSIONAL ELECTROCUTING LIGHT TRAP

INSTALLATION AND APPLICATIONREMOVE ALL PACKING MATERIALS BEFORE INSTALLATION

See Parts List (Page 16)For Part Descriptions

Place wall-mounted traps down low to best catch day-flying insects like the housefly.

With very few exceptions, the lower any light trap is placed the more effective it will be against flies!

Page 7: OWNER'S MANUAL - Gilbert Industries, Inc. · OWNER'S MANUAL INSTALLATION • OPERATION • PARTS For Models: 711, 601T, 601TJ, 601E, 601C, 220, 607, 705, 605 2000GT, 2002GT, 1999GT,

4528-S(2)

4530-S (2)

Model 607 Hall Stalker™

INSTALLATION INSTRUCTIONS

1. THIS UNIT IS DESIGNED FOR INDOOR USE ONLY.

2. LAMPS SHOULD BE IN A HORIZONTAL POSITION WHEN UNIT IS PROPERLY INSTALLED.

3. FLUSH WITH CEILING OR SUSPEND 7 1/2 - 10 FEET ABOVE FLOOR OR 6" ABOVE PRODUCT STACKS.

The Hall Stalker™ features flush-mount capability for low ceiling areas. Most effective against night-fliers, but fairly effective against flies when there is not room for a low, wall-mounted trap or sconce trap. Mount flush with ceiling or suspend from ceiling using eyebolts. To replace lamps, guard must be removed from tray side of trap by the removal of 4 screws.

MODEL: Gilbert® 607 "Hall Stalker"

7

PROFESSIONAL ELECTROCUTING LIGHT TRAP

INSTALLATION AND APPLICATIONREMOVE ALL PACKING MATERIALS BEFORE INSTALLATION

See Parts List (Page 16) For Part Descriptions

Ceiling traps will catch flies, but it is in the nature of flies to be below five feet high(even skimming the floor) when they are most responsive.

Traps are also more easily and more likely to be maintained when installed at waist level.

Ceiling-hung flytraps are the best choice for night-fliers. However, night-fliers respond to light more quickly and at greater distances than day-fliers,

and can usually be handled with strategic use of lighting and a well designed systemconsisting primarily of low, wall-mounted, professional flytraps.

Traps placed in double or triple-door entrance foyers are most effective. Bottlenecks, corners,and stairwells also make excellent trap locations to intercept flying insects before they reach

a production area, kitchen, dining area, or operating room.

Page 8: OWNER'S MANUAL - Gilbert Industries, Inc. · OWNER'S MANUAL INSTALLATION • OPERATION • PARTS For Models: 711, 601T, 601TJ, 601E, 601C, 220, 607, 705, 605 2000GT, 2002GT, 1999GT,

15

8 3/4"

1/8"

EYEHOOK (2)

6001

4512

SIDE COVER

6011(2)

46044614

4581

WO

RKH

ORS

E 5

4530-S(2)

6005 (2)

5009 (2)SEEDETAIL A

4010 (2) 4041 (4)

4049 (4)

6033(PLUNGE) 6062 (2)

(KNOB)

TRAY

6027

53"

DIVIDER (2)

DETAIL A:GROUND TERMINAL:8-32x1/4" RHMS SECURED BY8-32 HEX NUT

BACK PANEL

4528-S(2)

MODEL: Gilbert® 705 "Night Hawk"

8

INSTALLATION INSTRUCTIONS

1. THIS UNIT IS DESIGNED FOR INDOOR USE ONLY.

2. LAMPS SHOULD BE IN A HORIZONTAL POSITION WHEN UNIT IS PROPERLY INSTALLED.

3. SUSPEND 8-10 FEET ABOVE FLOOR.OR 6" ABOVE PRODUCT STACKS.

The Night Hawk™ features excellent effectiveness against night flying insects and is fairly effective against flies. Trap position (high for night-fliers / low for flies) has more to do with this than trap design. Ceiling suspend the Night Hawk™ with chain (not included) approximately 8' above floor or 6" above product stacks.

Model 705 Night Hawk™PROFESSIONAL ELECTROCUTING LIGHT TRAP

INSTALLATION AND APPLICATIONREMOVE ALL PACKING MATERIALS BEFORE INSTALLATION

See Parts List (Page 16) For Part Descriptions

Light traps will catch flies better when there is less sunlight to compete with.Window tinting film will screen out most UV (ultraviolet) which is the most

attractive part of sunlight for most flying insects.

Don't worry. ordinary lighting (such as flourescent lamps) will not competewith or reducethe effectiveness of Insect Light Traps (ILTs) much, if at all.

Light traps will do their best as the sun goes down.The theory is that flies see light traps as open windows.

And, as the sun sets, they attempt to leave the dark room and instead are caught in the trap.

Page 9: OWNER'S MANUAL - Gilbert Industries, Inc. · OWNER'S MANUAL INSTALLATION • OPERATION • PARTS For Models: 711, 601T, 601TJ, 601E, 601C, 220, 607, 705, 605 2000GT, 2002GT, 1999GT,

INSTALLATION INSTRUCTIONS

1. THIS UNIT IS DESIGNED FOR INDOOR USE ONLY.

2. LAMPS SHOULD BE IN A HORIZONTAL POSITION WHEN UNIT IS PROPERLY INSTALLED.

3. FOR CEILING MOUNTING: SUSPEND 8-10 FEET ABOVE FLOOR OR 6" ABOVE PRODUCT STACKS.

4. FOR FLAT-WALL MOUNTING: USING A LEVEL AND PEN-CIL, DRAW A SRAIGHT 33" LINE 24"-48" ABOVE FLOOR. COME IN 1/4" FROM ONE END AND MARK ACROSS THAT LINE. MEASURE 32" FROM THAT POINT AND MAKE A SEC-OND MARK. MOUNT THE TWO SCREWS (PROVIDED) AT THE CROSSPOINTS, LEAVING 1/2" OF THE SCREW STICKING OUT. SLIDE UNIT ONTO MOUNTING SCREWS AND CON-NECT TO AC POWER.

NOTE: IF MOUNTING ON MASONRY, USE A 3/16" BIT (NOT PROVIDED) AND DRILL OUT THE TWO CROSS MARKS AND INSERT THE TWO PLASTIC ANCHORS (PROVIDED) BEFORE MOUNTING THE TWO SCREWS.

GROUND TERMINAL:8-32x3/8" RHMS SECURED BY8-32 HEX NUT

DETAIL A

TRAY

4039(4)

4049(8)

4010 (4)

5009 (2)

4512 6001

SEE DETAIL A

4581

4530-S(2)

4614

4604

4528-S(2)

6027

EYEHOOK (2)

6062 (2)6033(ACTIVATOR PLUNGE)

8354(2)

8354(2)

54"

7"

13"

4604

9

The Night Eagle™ features superior effectiveness against night-flying insects (especially those with large circular flight patterns). This trap is most often used above and perpendicular to shipping/reciev-ing docks (take care not to locate any traps where additional insects can be attracted into the facility). Adding optional back reflector panel converts 605 to 605WD Wild Dragon in order to target flies (with low wall-mount installation).

Model 605 Night Eagle™

MODEL: Gilbert® 605 "Night Eagle"

Model: Gilbert® 605WD "Wild Dragon" is identical to 605 except the "WD"

includes a reflector panel for wall mounting.

See Parts List (Page 16) For Part Descriptions

PROFESSIONAL ELECTROCUTING LIGHT TRAP

INSTALLATION AND APPLICATIONREMOVE ALL PACKING MATERIALS BEFORE INSTALLATION

See Parts List (Page 16) For Part Descriptions

Taking into account the photoperidoc nature of flies, an effort should be made to spread the trapsevenly throughout a facility so that when such an insect does enter a responsive period

there will be a trap nearby.

Page 10: OWNER'S MANUAL - Gilbert Industries, Inc. · OWNER'S MANUAL INSTALLATION • OPERATION • PARTS For Models: 711, 601T, 601TJ, 601E, 601C, 220, 607, 705, 605 2000GT, 2002GT, 1999GT,

ELECTRICALCOVER

4560 (2)

4538 (2)Starter Base

6012 (2)Bushings

5003

4539 Starter(2)

4582 BACK

FRONT

BODY

ELECTRICALCOVER

LAMPHOLDER PLATE

REFLECTOR

GROUND SCREW & NUT

4515

5003(2)

4526 (4)

4520 (2)

TOP

Gilbert® Flying Venus™WALL-SCONCE / FLY TRAPS

First, be sure to remove protective plastic sheet-ing from brass units. Nev-er clean brass surface with ammonia cleaner to avoid removing protec-tive lacquer.

The Flying Venus™ is a serious integrated pest management tool. Though not as powerful as our larger traps, Venus goes unrec-ognized as a flytrap in elegant dining rooms, hospital hallways, etc., adding a whole new line of defense, increasing the effec-tiveness of the overall system and helping to reduce the need for chemical methods of control.

A decorative electrical cord (120v grounded) is provided. How-ever, we recommend having Venus hardwired for aesthetics (universal and keyhole mounts provided).

Lamps should be replaced regularly to maintain peak perfor-mance: See gilbertinc.com/lamprep.htm

NOTE: All sconce flytraps have both 16" & 19 3/16" keyhole mounting centers. For mounting on wood, use th 2 screws pro-vided. For mounting on masonary, drill a 3/16" hole and insert the plastic anchors first.

4538 Starter Base(2)

4539 Starter(2)

2012GT "FLYING VENUS"1999GT "FLYING VENUS"

2000GT "FLYING VENUS" 2002GT "FLYING VENUS"

10

See Parts List(Page 16)

See Parts List(Page 16)

See Parts List(Page 16)

See Parts List(Page 16)

DA

MA

R

REPLACE STARTERIn our most beautiful, super-thin (only 2-3/4" deep), 2000GT Flying Venus™, Gilbert® glueboards are scored for bending into a "V" shape for a perfect, space saving fit .

If necessary, to prevent lamp heated glue from oozing out the end of the "V", bend 1/2" up at each end (form-ing a tray to contain glue).

If it should ever be necessary, remove two screws to access and replace starter (located in-side the triangular compartment on all Flying Venus™ traps).

Venus' fly-catching glueboard is completely concealed; yet with the lift of a finger, her magnetic face swings up for easy glueboard replacement.

Glueboards are easily placed flat in both the 2002GT AND 2012GT.

This trap is being replaced by themore effective 2012GT (at right).

Page 11: OWNER'S MANUAL - Gilbert Industries, Inc. · OWNER'S MANUAL INSTALLATION • OPERATION • PARTS For Models: 711, 601T, 601TJ, 601E, 601C, 220, 607, 705, 605 2000GT, 2002GT, 1999GT,

11

MODEL: Gilbert® 2004GT"Leonardo Da Trapi"

PROFESSIONAL GLUEBOARD LIGHT TRAP

INSTALLATION AND APPLICATIONREMOVE ALL PACKING MATERIALS BEFORE INSTALLATION

See Parts List (Page 16)For Part Descriptions

24 - 60”

INSTALLATION INSTRUCTIONS

1. THIS UNIT IS DESIGNED FOR INDOOR USE ONLY.

2. LAMPS SHOULD BE IN A HORIZONTAL POSITION WHEN UNIT IS PROPERLY INSTALLED.

3. USING A LEVEL AND PENCIL, DRAW A STRAIGHT 20" LINE 24"-60" ABOVE FLOOR. COME IN 1/4" FROM ONE END AND MARK ACROSS THAT LINE. MEASURE 19 3/16" FROM THAT POINT AND MAKE A SECOND MARK. MOUNT THE TWO SCREWS (PROVIDED) AT THE CROSSPOINTS, LEAVING 1/2" OF THE SCREW STICKING OUT. SLIDE UNIT ONTO MOUNTING SCREWS AND CONNECT TO AC POWER. NOTE: IF MOUNTING ON MASONRY, USE A 3/16" BIT (NOT PRO-VIDED) AND DRILL OUT THE TWO CROSS MARKS AND INSERT THE TWO PLASTIC ANCHORS (PROVIDED) BEFORE MOUNTING THE TWO SCREWS.

4. WE HIGHLY RECOMMEND THE HARDWIRED, CORDLESS LOOK.

The Gilbert® 2004GT Leonardo Da Trapi™ is the world's first, serious flytrap art. You can stick with Leo's Mona Lisa Masterpiece (included) or slip-in a masterpiece (or ad) of your own. (See gilbertinc.com/masterpiece.htm). Really set yourself apart with premium custom-punched frames.

The Leonardo Da Trapi™ is hung, like other masterpieces, where it looks the best.

However, keep in mind, the lower any trapis placed, almost always, makes it more

effective against flies.

Though glueboard flytraps are quite snugwith a bug; we highly recommend that NO

insect light trap be placed directly overfood or food preparation surfaces.

For Most Complete info:How To Use Flytrapswww.gilbertinc.com

Phone (800) 643-0400

CHOOSE! (1) the standard six foot, 3-wire power cord, or (2) the highly recommended hard-wire version! Yes, we highly recom-mend the optional hard-wire version for the more aesthetically pleasing, cordless look. Universal knockouts and keyhole mounting slots provided.

Page 12: OWNER'S MANUAL - Gilbert Industries, Inc. · OWNER'S MANUAL INSTALLATION • OPERATION • PARTS For Models: 711, 601T, 601TJ, 601E, 601C, 220, 607, 705, 605 2000GT, 2002GT, 1999GT,

-1

The Sticky Fox™ has key-hole slots for wall-mounting and knock-outs for under-counter mounting. Generally, the lower any trap is placed, the more effective it is against flies. The Fox is normally mounted about 24" above floor. Holds 1-3 large 22 x 5" glueboards.

Be sure to bend the 1/2" scored-edge of glueboards up to help retain insects! The first bent glueboard should be wedged into the bottom of the two removable trays (one tray goes in the bottom of the trap, the second will slide-in on pegs between the lamps). An-other glueboard may be slipped into holder behind top lamp (lower scored edge will fold).

MODEL: Gilbert® 225GT"Sticky Fox"

See Parts List (Page 16) For Part Descriptions

Model 225GT Sticky Fox™INSTALLATION INSTRUCTIONS

1. THIS UNIT IS DESIGNED FOR INDOOR USE ONLY.

2. FOR HORIZONTAL MOUNTING: USING A LEVEL AND PENCIL, DRAW A STRAIGHT 17" LINE 24"-48" ABOVE FLOOR. COME IN 1/4" FROM ONE END AND MARK ACROSS THAT LINE. MEASURE 16" FROM THAT POINT AND MAKE A SECOND MARK. MOUNT THE TWO SCREWS (PROVIDED) AT THE CROSSPOINTS, LEAVING 1/2" OF THE SCREW STICKING OUT. SLIDE UNIT ONTO MOUNTING SCREWS AND CONNECT TO AC POWER.

3. FOR VERTICAL MOUNTING: USING A LEVEL AND PENCIL, DRAW A STRAIGHT 7" LINE 24"-48" ABOVE FLOOR. COME IN 1/4" FROM ONE END AND MARK ACROSS THAT LINE. MEASURE 5 3/4" FROM THAT POINT AND MAKE A SECOND MARK. MOUNT THE TWO SCREWS (PROVIDED) AT THE CROSSPOINTS, LEAVING 1/2" OF THE SCREW STICKING OUT. SLIDE UNIT ONTO MOUNTING SCREWS AND CONNECT TO AC POWER.

NOTE: IF MOUNTING ON MASONRY, USE A 3/16" BIT (NOT PROVIDED) AND DRILL OUT THE TWO CROSS MARKS AND INSERT THE TWO PLASTIC ANCHORS (PROVIDED) BEFORE MOUNTING THE TWO SCREWS.

5/8" BEND >

Another tray andglueboard will >will slip In between the lamps

12

PROFESSIONAL GLUEBOARD LIGHT TRAP

INSTALLATION AND APPLICATIONREMOVE ALL PACKING MATERIALS BEFORE INSTALLATION

See Parts List (Page 16)For Part Descriptions

The first glueboard may be placed in the removable tray in the bottom of the trap.

Yet another glueboard may alos be placed in the clip between the lamps.

When mounted horixontally, there are 3 places for glueboards to be placed in the trap. Use any one or all three:

When mounted vertically, the clip between the lamps is the best place to place a glueboard. Another in the side tray (a special clip designed to hold this tray and glueboard in place is available).

Page 13: OWNER'S MANUAL - Gilbert Industries, Inc. · OWNER'S MANUAL INSTALLATION • OPERATION • PARTS For Models: 711, 601T, 601TJ, 601E, 601C, 220, 607, 705, 605 2000GT, 2002GT, 1999GT,

13

MODEL: Gilbert® 601GT "Sticky Lizard"

Model 601GT Sticky LizardPROFESSIONAL GLUEBOARD LIGHT TRAP

INSTALLATION AND APPLICATIONREMOVE ALL PACKING MATERIALS BEFORE INSTALLATION

See Parts List (Page 16)For Part Descriptions

Contrary to midleading sales talk and misused research, flies do not explode in electrocuters. Theissue deserves consideration, but sincere scientific consideration, not exaggerated marketing hype.

Gilbert® makes both electrocuters and glueboard flytraps and has long emphasized thoughtful,proper placement, and eliminating flies before they get into highly critical areas.

Join the scientific revolution: www/gilbertinc.com/eltvsgt.htm

6 - 32”

FLOOR

INSTALLATION INSTRUCTIONS

1. FOR VERTICAL, FLAT-WALL MOUNTING: USING A LEVEL AND PENCIL, DRAW A STRAIGHT 10" LINE 32"-57" ABOVE FLOOR. COME IN 1/4" FROM ONE END AND MARK ACROSS THAT LINE. MEASURE 8 3/4" FROM THAT POINT AND MAKE A SECOND MARK. MOUNT THE TWO SCREWS (PROVIDED) AT THE CROSSPOINTS, LEAVING 1/2" OF THE SCREW STICKING OUT. SLIDE UNIT ONTO MOUNTING SCREWS AND CONNECT TO AC POWER.

2. FOR HORIZONTAL, FLAT-WALL MOUNTING: USING A LEVEL AND PENCIL, DRAW A STRAIGHT 21" LINE 20"-46" ABOVE FLOOR. COME IN 1/4" FROM ONE END AND MARK ACROSS THAT LINE. MEASURE 19 5/8" FROM THAT POINT AND MAKE A SECOND MARK. MOUNT THE TWO SCREWS (PROVIDED) AT THE CROSSPOINTS, LEAVING 1/2" OF THE SCREW STICKING OUT. SLIDE UNIT ONTO MOUNTING SCREWS AND CONNECT TO AC POWER.

3. FOR VERTICAL, CORNER MOUNTING: USING A LEVEL AND PENCIL, DRAW A STRAIGHT 9" LINE FROM THE CORNER IN BOTH DIRECTIONS, 32"-57" ABOVE FLOOR. MEASURE 9 13/16" FROM THE CORNER AND MAKE A CROSS MARK ON BOTH LINES. MOUNT THE TWO SCREWS (PROVIDED) AT THE CROSSPOINTS, LEAVING 1/2" OF THE SCREW STICKING OUT. SLIDE UNIT ONTO MOUNTING SCREWS AND CONNECT TO AC POWER.

NOTE: IF MOUNTING ON MASONRY, USE A 3/16" BIT (NOT PROVIDED) AND DRILL OUT THE TWO CROSS MARKS AND INSERT THE TWO PLASTIC ANCHORS (PROVIDED) BEFORE MOUNTING THE TWO SCREWS.

The Sticky Lizard™ is for use indoors to control flies and other flying insects. It has keyhole slots located on the back for horizontal and vertical wall or corner installation and should be mounted 6" to 32" above floor for best results. When vertical, glueboards either slip into standard clips on each side of lamps or are folded, placed into Lizard's wings, and held in place by gravity, guard door and latch. When horizontal, the primary glueboard slips into a Lizard wing or clip in the bottom of the trap. A second (optional) glueboard will slip into the clip above the lamps.

Page 14: OWNER'S MANUAL - Gilbert Industries, Inc. · OWNER'S MANUAL INSTALLATION • OPERATION • PARTS For Models: 711, 601T, 601TJ, 601E, 601C, 220, 607, 705, 605 2000GT, 2002GT, 1999GT,

MODEL: Gilbert®219GT "Sticky Tiger"

INSTALLATION INSTRUCTIONS

1. THIS UNIT IS DESIGNED FOR INDOOR USE ONLY.

2. LAMPS SHOULD BE IN A HORIZONTAL POSITION WHEN UNIT IS PROPERLY IN-STALLED.

3. USING A LEVEL AND PENCIL, DRAW A SRAIGHT 17" LINE 24"-48" ABOVE FLOOR. COME IN 1/4" FROM ONE END AND MARK ACROSS THAT LINE. MEASURE 16" FROM THAT POINT AND MAKE A SECOND MARK. MOUNT THE TWO SCREWS (PROVIDED) AT THE CROSSPOINTS, LEAVING 1/2" OF THE SCREW STICKING OUT. SLIDE UNIT ONTO MOUNTING SCREWS AND CONNECT TO AC POWER. NOTE: IF MOUNTING ON MASONRY, USE A 3/16" BIT (NOT PROVIDED) AND DRILL OUT THE TWO CROSS MARKS AND INSERT THE TWO PLASTIC ANCHORS (PROVIDED) BE-FORE MOUNTING THE TWO SCREWS.

4. USE AS FREE-STANDING PORTABLE (HANDLE AND 3 MAR-RESISTANT FEET).

.

The 219GT Sticky Tiger™ has key hole slots located on back for wall installation (usually mounted approximately 24" above floor). The Tiger may also be used as a free-standing portable (see Guerrilla portable use instructions at left). A 2nd (optional) glueboard can be wedged into holder behind top lamp and folded at dotted-line to help retain glue.

Model 219GT Sticky Tiger™

14

PROFESSIONAL GLUEBOARD LIGHT TRAP

INSTALLATION AND APPLICATIONREMOVE ALL PACKING MATERIALS BEFORE INSTALLATION

See Parts List (Page 16)For Part Descriptions

Gilbert® has had superior trap designs since Don Gilbert built the first, truly professional flytrap in 1967.Yet, he maintained, it was not his trap designs, but his philosophy that was most responsible for his success.

Don (and his distributors) were so successful at it, Gilbert® was granted a registered trademark.

Page 15: OWNER'S MANUAL - Gilbert Industries, Inc. · OWNER'S MANUAL INSTALLATION • OPERATION • PARTS For Models: 711, 601T, 601TJ, 601E, 601C, 220, 607, 705, 605 2000GT, 2002GT, 1999GT,

4528-S

4530-S

15

MODEL: Gilbert® 747GT "Sticky Bear"

INSTALLATION INSTRUCTIONS

1. THIS UNIT IS DESIGNED FOR INDOOR USE ONLY.

2. LAMPS SHOULD BE IN A HORIZONTAL POSITION WHEN UNIT IS PROPERLY INSTALLED.

3. USING A LEVEL AND PENCIL, DRAW A STRAIGHT 33" LINE APPROX. 3' ABOVE FLOOR. COME IN 1/4" FROM ONE END AND MARK ACROSS THAT LINE. MEASURE 32" FROM THAT POINT AND MAKE A SECOND MARK. MOUNT THE TWO SCREWS (PRO-VIDED) AT THE CROSSPOINTS, LEAVING 1/2" OF THE SCREW STICKING OUT. SLIDE UNIT ONTO MOUNTING SCREWS AND CONNECT TO AC POWER.

NOTE: IF MOUNTING ON MASONRY, USE A 3/16" BIT (NOT PROVIDED) AND DRILL OUT THE TWO CROSS MARKS AND INSERT THE TWO PLASTIC ANCHORS (PROVIDED) BEFORE MOUNTING THE TWO SCREWS.

The 747GT Sticky Bear™ features superior effectiveness for control of flies and other flying insects. The Bear has key hole slots located on back for wall installation. Generally speaking, the lower any trap is placed, the more effective it is against flies. The Bear is normally mounted 24" above floor. Two glueboards are normally placed in the catch tray of the trap. 2 (optional) glueboards can be wedged into holder behind top lamp and folded at dotted-line to help retain glue.

Model 747GT Sticky Bear™PROFESSIONAL GLUEBOARD LIGHT TRAP

INSTALLATION AND APPLICATIONREMOVE ALL PACKING MATERIALS BEFORE INSTALLATION

See Parts List (Page 16) For Part Descriptions

Don Gilbert's idea of flytraps, as only one tool in his bag, to be applied with a sincere desireto help customers in any way he could, was simple and honest.

Today, Don's son endeavors to carry that philosophy forward,leading the way to the truly professional, scientific use of flytraps

Page 16: OWNER'S MANUAL - Gilbert Industries, Inc. · OWNER'S MANUAL INSTALLATION • OPERATION • PARTS For Models: 711, 601T, 601TJ, 601E, 601C, 220, 607, 705, 605 2000GT, 2002GT, 1999GT,

TROUBLESHOOTING GUIDEAll repairs must be performed by qualified personnel. Repair can be accomplished with a few simple tools.

Do not attempt any major repair without consulting the factory.PROBLEM PROBABLE CAUSE CORRECTION

1. Remove lamp from its socket. Reverse ends and replace in socket. (Turn lamp upside down).

2. Replace Starter (Models 1998GT, 1999GT, 2000GT, 2002GT, 2012GT, 219GT, 220, 225GT & 601TJ).

1. Not grounded.

2. Bad Starter.

1. Check fuse or circuit breaker.

2. Check connections from line cord.

3. Repair or replace.

4. Check actuator for proper closure on guard or tray.

1. Not plugged in to a live receptacle.

2. Loose connections.

3. Faulty line cord.

4. Interlock switch.

No lightsor voltage to the grid.

LampFlickers

1. Shorted grid wires.

2. Loose connection.

3. Faulty transformer.

1. Disconnect power. Examine grid wires to verify that no two wires are touching each other. Be sure there is sufficient gap between two wires. Bend back into alignment.

2. Disconnect power. (a) Make sure high-voltage leads are connected to the grid lugs. (b) Remove the unit's cover by drilling out rivets (on Model 601C see specific instructions for removing inner-body on page 4). Check all connections to and from transformer then retest.

3. Replace (See schematic).

Lights but no voltageto grid.

1. Arc the grid with screwdriver.

2. Check all sockets for proper seating and alignment.

3. Replace.

4. (a) Remove cover by drilling out rivets (on Model 601C see specific instructions for removing inner-body on page 4). Check all connections to and from ballast.

5. Replace.

6. Replace ballast (see Schematic).

7. Replace Starter (1998GT, 1999GT, 219GT, 601GT, 220, 225GT, 601TJ, 2000GT, 2002GT, 2012GT).

1. Temp. under 70 degrees F.

2. Lamps not seated properly.

3. Cracked lamp socket.

4. Loose connection.

5. Burned out lamp(s).

6. Faulty ballast.

7. Bad Starter

No lights,but voltageto grid(if one).

1. Unplug unit and bend grid wires into alignment.

2. Remove any and all material from grid or insulator(s).

3. Unit specifically designed to operate on either 120 volt, 60HZ, or 230volt, 50HZ. Check line voltage.

4. Check for hairline cracks or breaks. Replace if cracked.

5. Allow unit to operate until dry. Intermittent arcing will continue until completely dry.

1. Gap between grid wires is not sufficient.

2. Foreign material stuck on grid or insulator(s).

3. Excessive line voltage.

4. Cracked insulator.

5. Moisture.

Intermittentor continousarcingbetweengrid wires.

71146044581500946144049

4528-S4530-S40104041

4512

6062

60546044581500946144049

4528-S4530-S40104039

4512

6062

219GT

45605005

45284530

4043

45126064604960624539

4220

1999GT/2012GT

45605003

4524

4515

4539

4219

225GT

45605005

45284530

4044

4512

45396033-14220

747GT

45815009

4528-S4530-S

4041

4512

6062

4220

2002GT

45605005

4524

4515

4539

4220

MODEL TRANSFORMERBALLASTLAMPSWITCHINSULATORLAMPHOLDERLAMPHOLDERGRID GUARDDIFFUSER DEFLECTORCORDHANDLE FEETKNOBSTARTERTRAY PEGGLUEBOARD

PARTS LIST - 120V, 60HZ (See Reference Drawings For Parts Locations)

601T460445815009461440484526453640054031

40644512

6062

601E460445815009461440484526

400540334066

4512

2204604456050054614404945284530

4010x4041

45126064604960624539

70546044581500946144049

4528-S4530-S40104041

4512

6062

60746044581500946144048

4528-S4530-S40054037

4512

6062

601TJ460445605005461440484524453640054021

40644512

60624539

2000GT

45605005

4524

4515

4539

4219

601GT

45605005

45284530

4021

4512

4539

4220

2004GT

45605005

4524

4515

45396033-14220