p he re initial controller alarm light illuminates … · clean rain sensor #8 screw level line...

1
TOP VE HE LE L RE TOP LEVEL HERE " $ ACCESS HERE TO CLEAN RAIN SENSOR #8 SCREW LEVEL LINE ESP-SMT SMART MODULAR CONTROLLER Allow 11" clearance to the left side of the template to allow the door to open fully. MOUNTING TEMPLATE #8 SCREW #8 SCREW #8 SCREW P/N: 637654-01 ALARM ENGLISH ESPAÑOL ESP-SMT SMART MODULAR CONTROLLER FINE-TUNE WATERING SET DATE & TIME AUTO SPECIAL FEATURES SYSTEM REVIEW INPUT ZONE INFORMATION CONFIGURE CONTROLLER RESTORE SETTINGS MANUAL WATERING OFF " ESP-SMT Smart Modular Control System Installation & Operation Guide LAWN SPRINKLER CONTROL -DOMESTIC- INPUT: 120 VAC, 0.3 AMPS, 60Hz OUTPUT: 25.5 VAC, 1.0 AMPS, 60Hz SMX SENSOR ACCESSORY IF DISPLAY IS SCRAMBLED OR BLANK, PUSH THE RISK OF FIRE, EXPLOSION AND ELECTRICAL SHOCK. THIS CONTROLLER USES A NON-REPLACEABLE LITHIUM BATTERY. DISPOSE OF ALL ELECTRONIC PRODUCTS IN ACCORDANCE WITH LOCAL LAWS AND FEDERAL REGULATIONS. RESET RESET BUTTON This device complies with Part 15 of the FCC Rules. Operation is subjected to the following two conditions: (1) (2) This class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Cet appariel Numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. This device may not cause harmful interference and This device must accept any interference received, including interference that may cause undesired operation. WARNING LAWN SPRINKLER CONTROL -DOMESTIC- INPUT: 120 VAC, 0.3 AMPS, 60Hz OUTPUT: 25.5 VAC, 1.0 AMPS, 60Hz SMX SENSOR ACCESSORY IF DISPLAY IS SCRAMBLED OR BLANK, PUSH THE RI SK OF FI RE , EX PL OS IO N AN D EL EC TR IC AL SH OC K. TH IS CO NT RO LL ER US ES A NO N- RE PL AC EA BL E LI TH IU M BA TT ER Y. DI SP OS E OF AL L EL EC TR ON IC PR OD UC TS IN AC CO RD AN CE WI TH LO CA L LA WS AN D FE DE RA L RE GU LA TI ON S. RESET RESET BUTTON This device complies with Part 15 of the FCC Rules. Operation is subjected to the following two conditions: (1) (2) This class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Cet appariel Numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. This device may not cause harmful interference and This device must accept any interference received, including interference that may cause undesired operation. WARNING & ALARM ENGLISH ESPAÑOL ESP-SMT SMART MODULAR CONTROLLER FINE-TUNE WATERING SET DATE & TIME AUTO SPECIAL FEATURES SYSTEM REVIEW INPUT ZONE INFORMATION CONFIGURE CONTROLLER RESTORE SETTINGS MANUAL WATERING OFF LAWN SPRINKLER CONTROL -DOMESTIC- INPUT: 120 VAC, 0.3 AMPS, 60Hz OUTPUT: 25.5 VAC, 1.0 AMPS, 60Hz SMX SENSOR ACCESSORY IF DISPLAY IS SCRAMBLED OR BLANK, PUSH THE RI SK OF FI RE , EX PL OS IO N AN D EL EC TR IC AL SH OC K. TH IS CO NT RO LL ER US ES A NO N- RE PL AC EA BL E LI TH IU M BA TT ER Y. DI SP OS E OF AL L EL EC TR ON IC PR OD UC TS IN AC CO RD AN CE WI TH LO CA L LA WS AN D FE DE RA L RE GU LA TI ON S. RESET RESET BUTTON This device complies with Part 15 of the FCC Rules. Operation is subjected to the following two conditions: (1) (2) This class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Cet appariel Numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. This device may not cause harmful interference and This device must accept any interference received, including interference that may cause undesired operation. WARNING $ ( " ENGLISH ESPAÑOL ENGLISH ESPAÑOL OFF FINE-TUNE WATERING SET DATE & TIME AUTO SPECIAL FEATURES SYSTEM REVIEW INPUT ZONE INFORMATION CONFIGURE CONTROLLER MANUAL WATERING RESTORE SETTINGS SET CURRENT DATE AND TIME 02 PM RETR. SIG. 24 Mar 2009 :54 Welcome To The Rain Bird ESP-SMT Smart Control System Initial Controller Setup Controls, Switches and Indicators Set Date & Time Page 7-8 of User-manual Box Contents and Required Tools Locate The Sensor Input Zone Information Page 19-33 of User-manual Installing The Sensor Page 68-69 of User-manual Installing The Controller Page 56-67 of User-manual Configure Controller Page 9-18 of User-manual ESP-SMT Smart Modular Control System Quick I (for ESP-SMT panels with a March 31, 2011 date code or newer) nstallation & Setup Guide ESP-SMT Controller (or retro-fit panel only) * Controller Mounting Hardware * Controller Mounting Template ESP-SMT Installation & Operation Guide ESP-SMT Site Profile Chart ESP-SMT Installation & Quick Setup Poster SMT Weather Sensor Weather Sensor Debris Screen Weather Sensor Mounting Bracket Mounting Bracket Hardware Sensor Wire - 25 feet of 20-2 UV rated wire (not rated for direct burial) * Controller models only Installation Tools (not shown) Do’s Don't’s Marking pencil for template Wire stripper Torpedo level Drill bit & hammer drill Ladder (if mounting sensor more than 6' above grade) Phillips slot-head screwdriver Box Contents Mount and Wire the Sensor " $ SITE ZIP CODE Enter Site Zip Code 92010 NEXT BACK BLOCK WATERING ON SPECIFIC DAY OF WEEK None Monday Tuesday Wednesday Thursday Friday Saturday Sunday Sat & Sun SELECT BACK SELECT ALLOWED WATER DAYS No Restrictions By Days of the Week Even Days: 2,4,6,… 30 Odd Days: 1,3,5,…no31 Cyclical: Every x Days BACK INITIAL CONTROLLER & ZONE SET-UP DIAL POSITIONS (LIGHT BLUE) ALARM LIGHT ILLUMINATES WHEN CONDITIONS PREVENT IRRIGATION LARGE BACK-LIT DOT-MATRIX DISPLAY SCREEN TITLE SCREEN TEXT FUNCTION LABELS FOR SET-UP & NAVIGATION NAVIGATION BUTTONS WITH ACCELERATOR ENGLISH/SPANISH BUTTON FOR EASY SWITCHING OF DISPLAY LANGUAGE ZONE SETUP Zone Setup Wizard Copy Zone to Zone SELECT SELECT ZONE ENABLED Zone 3 NEXT BACK OFFENABLE SELECT ZONE Zone 3 NEXT BACK OFF PLANT TYPE Grass Lawn Annuals Ground Cover Shrubs Desert Plants Trees Mixed Planting - OR - Custom Plant Factors Zone 1 SELECT BACK PLANT WATER NEED Mixed Plants High Average Low SELECT BACK Zone 1 PLANT DENSITY Dense Medium Sparse SELECT BACK Zone 1 Mixed Plants PLANT MATURITY Established - OR - Newly Planted SELECT BACK Zone 2 Grow-in Period NEWLY PLANTED Day For Next 14 Days Water Every Calendar Cycles per Day 6 Minutes Per Cycle 09:00 AM to 04:00 PM 8 Zone 2 NEXT BACK REVIEW ON Rotor 0.45 in/hr 8° - up Medium 75% Shade Sandy Loam Slope Shrubs Plants Established Zone 2 CHANGE Sparse ACCEPT Thank you for doing your part to conserve our most precious natural resource... WATER! The Rain Bird ESP-SMT “Smart” Modular Control System has many advanced features based on scientific agronomic principles. It is designed for you to easily and conveniently keep your client’s landscape healthy and vibrant by optimizing the irrigation schedule to match the plant water needs associated with changing weather conditions. You are about to install a controller that many of our field test participants commented that this control system is what they need to irrigate correctly and save water. They also stated that this controller is much easier and faster to program than any other controller they have used. To leverage the water savings potential of the ESP-SMT control system, it is important that you become familiar with both the basic as well as advanced capabilities of the controller. If you would like to better understand Plant-Soil-Water relationship principles or learn more about how to maximize the water savings and your profits with the ESP-SMT Smart Control System, we offer a free, comprehensive on-line tutorial program. To learn more, visit the Rain Bird website... www.rainbird.com Drive a mounting screw through hole in upper left corner of mounting base into mounting surface (do not tighten yet). Align mounting base to approximate level position. Drive a second screw into slot in lower right corner of mounting base (do not tighten yet). Assure mounting base is level, then tighten the screw in slot. To secure base, assure that all 3 additional screws are tightened to the mounting surface. Unscrew the captured screw to remove the wiring compartment cover and expose the wiring terminals. Strip the wire insulation 3/8” and insert bare, copper-leads into the tool-less connectors (polarity is not important). If the controller is powered, the green LED located adjacent to the terminal strip will illuminate once communication is established. Route the wire through the two openings in the wiring compartment cover, then tighten the captured screw to secure cover. Route the wires through the 3 holes located in the 2 mounting bracket arms for strain relief. Slide the sensor housing assembly over the top of the mounting arm and secure with the provided thumb screw. Adjust each of the mounting arms to assure that the sensor is secured in a level position. Slip the sensor debris cover onto top of sensor. Mount the Controller Remove the controller door from cabinet hinges. Open the face panel by grasping the crescent shaped finger hold on the top right side of the cabinet. Disconnect cable from back of panel. Remove controller panel from cabinet hinge pins. Drive a screw at eye level into the mounting wall surface. Leave approximately a 3/8" gap from wall. Slide controller keyhole slot (located on back of the cabinet) onto the screw. Secure controller by driving 3 screws into wall thru the holes located at bottom of controller. Set current Month. Set current Day of Month Set current Year. Set current Hour (assure AM or PM is correct). Set current Minutes. The ESP-SMT Smart Modular controller panel is designed to upgrade previously installed ESP-Modular controllers (ESP-SMT RETRO). Connect Sensor Wire to Controller " $ & Run provided wire or 18-2 AWG direct burial, UV rated wire from sensor to controller (200 ft. max). Strip wire insulation approx 3/8" and insert leads into connector located on back of front panel (polarity not important). Route the two wires through the provided channel and out through one of the knockouts, located in the bottom of the controller cabinet. Remote Programming of Controller Panel ( Insert 9-volt battery into the back of front panel to program the controller without AC power to the unit. Once completed, remove 9- volt battery from unit. NOTE: All of the programmed info- rmation will be saved in non-volatile memory so you can pre-program the controller in advance of AC power availability. Connect Field Wiring Connect each valves separate power wire to the corresponding station (zone) terminal. Connect a common wire to one of the leads on each valve. Connect the other end of the common wire to the terminal location labeled COM. NOTE: All 120V Power and Field Wiring (Valves & Pumps) is performed in the same manner as any other traditional time-based controller. For Pump, Master Valve and Control Valve Wiring Details, See User Manual – pages 61 to 62. ! ! Install sensor in a location that receives afternoon sun in order to measure the daily high temperature (South or West exposure is ideal). Mount weather sensor at least six feet above grade. Assure that sensor is free from obstructions to allow for collection and accurate measurement of rainfall. Do NOT install sensor in a location where spray from the sprinkler will collect in the sensor. Do NOT install the sensor where it will be located in the shade during the hottest part of the day. Do NOT install the sensor where rainfall will be blocked from entering the sensor funnel. ESP-SMT CONTROLLER SENSOR WIRE (MAX 200 FT.) SET CURRENT DATE AND TIME 24 Mar 2009 10:16 AM BACK NEXT WIRES FROM SMT SENSOR Enter SITE ZIP CODE Enter 1st Watering Window Select BLOCK WATER DAYS (if necessary) Select ALLOWED WATER DAYS Review Entered Info (Change or Accept) Enter GROW-IN Watering Window Enter 2nd Watering Window Select ZONE SETUP WIZARD method Select SPRINKLER TYPE Select SOIL TYPE Select DEGREE SLOPE Select SHADE FACTOR (all plants) Enter PLANT DENSITY (non grass) Enter PLANT MATURITY (all plants) Select ZONE # Select PLANT TYPE Enter NEWLY PLANTED schedule (if needed) ENABLE zone Enter PLANT WATER NEED (non grass) Review Entered Info (Change or Accept) Repeat process for all desired Zones. Rotate dial to INPUT ZONE INFORMATION position ALLOWED WATERING By Days of the Week 05:00 AM To 06:00 09:00 Grow-in: Daily PM AM To To 09:00 AM 11:45 04:00 PM PM CHANGE ACCEPT Mo We Fr SHADE FACTOR Full Sun 25% Shade 50% Shade 75% Shade Full Shade SELECT BACK Zone 1 P/N: 637728-01 03/31/11 Rotate dial to SET DATE & TIME position. " Rotate dial to CONFIGURE CONTROLLER position. $ & ( " SET ALLOWED WATER TIME 1st Watering Window AM To 06:00 06:00 PM 2nd Watering Window OFF NEXT BACK GROW-IN WATER WINDOW Water every day between AM To 05:00 09:00 PM NEXT BACK SOIL TYPE Sand Loamy Sand Sandy Loam Loam Clay Loam Silty Clay Clay Help SELECT BACK Zone 2 SPRINKLER TYPE Zone 2 Sprays Rotors Bubblers Rotary Nozzle Drip - OR - Time-Based SELECT BACK SET ALLOWED WATER TIME 1st Watering Window AM To 09:00 05:00 AM PM To 11:45 06:00 PM NEXT BACK 2nd Watering Window ON CYCLE/SOAK Select Slope in Deg. 0-2° 3-4° 5-7° 8°-up Cycle/Soak Automatic Max Cycle Min Min Soak (6) (40) Min Zone xx NEXT BACK

Upload: others

Post on 09-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: P HE RE INITIAL CONTROLLER ALARM LIGHT ILLUMINATES … · CLEAN RAIN SENSOR #8 SCREW LEVEL LINE ESP-SMT SMART MODULAR CONTROLLER Allow 11" clearance to the left side of the template

TOPVE HELE L RE

TOPLEVEL HERE

ACCESS HERE TOCLEAN RAIN SENSOR

#8 SCREW

LEVEL LINE

ESP-SMT SMART MODULAR CONTROLLER

Allow 11" clearance to the left side of thetemplate to allow the door to open fully.

MOUNTING TEMPLATE

#8 SCREW #8 SCREW #8 SCREW

P/N: 637654-01

ALARM

ENGLISH

ESPAÑOL

ENGLISH

ESPAÑOL

ESP-SMTSMART MODULAR CONTROLLER

FINE-TUNEWATERING

SET DATE& TIME

AUTO

SPECIALFEATURES

SYSTEMREVIEW

INPUT ZONEINFORMATION

CONFIGURECONTROLLER

RESTORESETTINGS

MANUALWATERING

OFF

ESP-SMT Smart Modular Control SystemInstallation & Operation Guide

LAWN SPRINKLER CONTROL-DOMESTIC-INPUT: 120 VAC, 0.3 AMPS, 60HzOUTPUT: 25.5 VAC, 1.0 AMPS, 60Hz

SMX SENSOR

ACCESSORY

IF DISPLAY IS SCRAMBLEDOR BLANK, PUSH THE

RISK OF FIRE, EXPLOSION AND ELECTRICAL SHOCK.THIS CONTROLLER USES A NON-REPLACEABLE LITHIUMBATTERY. DISPOSE OF ALL ELECTRONIC PRODUCTS INACCORDANCE WITH LOCAL LAWS AND FEDERAL REGULATIONS.

RESET

RESET BUTTON

This device complies with Part 15 of the FCC Rules.

Operation is subjected to the following two conditions:

(1)

(2)

This class B digital apparatus meets all requirements of the

Canadian Interference Causing Equipment Regulations.

Cet appariel Numérique de la classe B respecte toutes les

exigences du Règlement sur le matériel brouilleur du Canada.

This device may not cause harmful interference and

This device must accept any interference received,

including interference that may cause undesired operation.

WARNING

LAWN SPRINKLER CONTROL-DOMESTIC-INPUT: 120 VAC, 0.3 AMPS, 60HzOUTPUT: 25.5 VAC, 1.0 AMPS, 60Hz

SMX SENSOR

ACCESSORY

IF DISPLAY IS SCRAMBLEDOR BLANK, PUSH THE

RI SK OF FI RE , EX PL OS IO N AN D EL EC TR IC AL SH OC K.TH IS CO NT RO LL ER US ES A NO N- RE PL AC EA BL E LI TH IU MBA TT ER Y. DI SP OS E OF AL L EL EC TR ON IC PR OD UC TS INAC CO RD AN CE WI TH LO CA L LA WS AN D FE DE RA L RE GU LA TI ON S.

RESET

RESET BUTTON

This device complies with Part 15 of the FCC Rules.

Operation is subjected to the following two conditions:

(1)

(2)

This class B digital apparatus meets all requirements of the

Canadian Interference Causing Equipment Regulations.

Cet appariel Numérique de la classe B respecte toutes les

exigences du Règlement sur le matériel brouilleur du Canada.

This device may not cause harmful interference and

This device must accept any interference received,

including interference that may cause undesired operation.

WARNING

ALARM

ENGLISH

ESPAÑOL

ENGLISH

ESPAÑOL

ESP-SMTSMART MODULAR CONTROLLER

FINE-TUNEWATERING

SET DATE& TIME

AUTO

SPECIALFEATURES

SYSTEMREVIEW

INPUT ZONEINFORMATION

CONFIGURECONTROLLER

RESTORESETTINGS

MANUALWATERING

OFF

LAWN SPRINKLER CONTROL-DOMESTIC-INPUT: 120 VAC, 0.3 AMPS, 60HzOUTPUT: 25.5 VAC, 1.0 AMPS, 60Hz

SMX SENSOR

ACCESSORY

IF DISPLAY IS SCRAMBLEDOR BLANK, PUSH THE

RI SK OF FI RE , EX PL OS IO N AN D EL EC TR IC AL SH OC K.TH IS CO NT RO LL ER US ES A NO N- RE PL AC EA BL E LI TH IU MBA TT ER Y. DI SP OS E OF AL L EL EC TR ON IC PR OD UC TS INAC CO RD AN CE WI TH LO CA L LA WS AN D FE DE RA L RE GU LA TI ON S.

RESET

RESET BUTTON

This device complies with Part 15 of the FCC Rules.

Operation is subjected to the following two conditions:

(1)

(2)

This class B digital apparatus meets all requirements of the

Canadian Interference Causing Equipment Regulations.

Cet appariel Numérique de la classe B respecte toutes les

exigences du Règlement sur le matériel brouilleur du Canada.

This device may not cause harmful interference and

This device must accept any interference received,

including interference that may cause undesired operation.

WARNING

ENGLISH

ESPAÑOL

ENGLISH

ESPAÑOL

OFF

FINE-TUNEWATERING

SET DATE& TIME

AUTO

SPECIALFEATURES

SYSTEMREVIEW

INPUT ZONEINFORMATION

CONFIGURECONTROLLER

MANUALWATERING

RESTORESETTINGS

SET CURRENT DATE AND TIME

02 PM

RETR. SIG.

24 Mar 2009

:54

Welcome To The Rain Bird ESP-SMT Smart Control System

Initial Controller SetupControls, Switches and Indicators

Set Date & TimePage 7-8 of User-manual

Box Contents and Required Tools

Locate The Sensor Input Zone InformationPage 19-33 of User-manual

Installing The SensorPage 68-69 of User-manual

Installing The ControllerPage 56-67 of User-manual

Configure ControllerPage 9-18 of User-manual

ESP-SMT Smart Modular Control SystemQuick I

(for ESP-SMT panels with a March 31, 2011 date code or newer)nstallation & Setup Guide

ESP-SMT Controller (or retro-fit panel only)

* Controller Mounting Hardware

* Controller Mounting Template

ESP-SMT Installation & Operation Guide

ESP-SMT Site Profile Chart

ESP-SMT Installation & Quick Setup Poster

SMT Weather Sensor

Weather Sensor Debris Screen

Weather Sensor Mounting Bracket

Mounting Bracket Hardware

Sensor Wire - 25 feet of 20-2 UV rated wire(not rated for direct burial)

* Controller models only

Installation Tools (not shown)

Do’s Don't’s

Marking pencil for template

Wire stripper

Torpedo level

Drill bit & hammer drill

Ladder (if mounting sensor more than 6' above grade)

Phillips slot-head screwdriver

Box Contents

Mount and Wire the Sensor

SITE ZIP CODE

Enter Site Zip Code

92010NEXTBACK

BLOCK WATERING ONSPECIFIC DAY OF WEEKNone MondayTuesday WednesdayThursday FridaySaturday SundaySat & Sun

SELECTBACK

SELECT

ALLOWED WATER DAYS

No RestrictionsBy Days of the WeekEven Days: 2,4,6,… 30Odd Days: 1,3,5,…no31

Cyclical: Every x DaysBACK

INITIAL CONTROLLER & ZONE SET-UP DIAL POSITIONS (LIGHT BLUE)

ALARM LIGHT ILLUMINATES WHEN CONDITIONS PREVENTIRRIGATION

LARGE BACK-LITDOT-MATRIXDISPLAY

SCREEN TITLE

SCREEN TEXT

FUNCTION LABELS FOR SET-UP &NAVIGATION

NAVIGATION BUTTONS WITHACCELERATOR

ENGLISH/SPANISH BUTTON FOR EASY SWITCHING OF DISPLAYLANGUAGE

ZONE SETUP

Zone Setup WizardCopy Zone to Zone

SELECT

SELECT ZONE

ENABLEDZone 3

NEXTBACK OFF ENABLE

SELECT ZONE

Zone 3

NEXTBACKOFF

PLANT TYPE Grass Lawn AnnualsGround Cover ShrubsDesert Plants TreesMixed Planting

- OR - Custom Plant Factors

Zone 1

SELECTBACK

PLANT WATERNEEDMixed Plants

HighAverageLow

SELECTBACK

Zone 1

PLANT DENSITY

Dense Medium Sparse

SELECTBACK

Zone 1

Mixed Plants

PLANT MATURITY

Established- OR -

Newly Planted

SELECTBACK

Zone 2

Grow-in Period

NEWLY PLANTED

Day For Next 14 DaysWater Every Calendar

Cycles per Day 6Minutes Per Cycle09:00 AM to 04:00 PM

8

Zone 2

NEXTBACK

REVIEW ONRotor 0.45 in/hr

8° - upMedium

75% Shade

Sandy LoamSlopeShrubs

Plants Established

Zone 2

CHANGE

Sparse

ACCEPT

Thank you for doing your part to conserve our most precious natural resource... WATER!

The Rain Bird ESP-SMT “Smart” Modular Control System has many advanced features based on scientific agronomic principles. It is designed for you to easily and conveniently keep your client’s landscape healthy and vibrant by optimizing the irrigation schedule to match the plant water needs associated with changing weather conditions.

You are about to install a controller that many of our field test participants commented that this control system is what they need to irrigate correctly and save water. They also stated that this controller is much easier and faster to program than any other controller they have used.

To leverage the water savings potential of the ESP-SMT control system, it is important that you become familiar with both the basic as well as advanced capabilities of the controller. If you would like to better understand Plant-Soil-Water relationship principles or learn more about how to maximize the water savings and your profits with the ESP-SMT Smart Control System, we offer a free, comprehensive on-line tutorial program. To learn more, visit the Rain Bird website... www.rainbird.com

Drive a mounting screw through hole in upper left corner of mounting base into mounting surface (do not tighten yet).

Align mounting base to approximate level position. Drive a second screw into slot in lower right corner of mounting base (do not tighten yet).

Assure mounting base is level, then tighten the screw in slot.

To secure base, assure that all 3 additional screws are tightened to the mounting surface.

Unscrew the captured screw to remove the wiring compartment cover and expose the wiring terminals.

Strip the wire insulation 3/8” and insert bare, copper-leads into the tool-less connectors (polarity is not important).

If the controller is powered, the green LED located adjacent to the terminal strip will i l l u m i n a t e o n c e c o m m u n i c a t i o n i s established.

Route the wire through the two openings in the wiring compartment cover, then tighten the captured screw to secure cover.

Route the wires through the 3 holes located in the 2 mounting bracket arms for strain relief.

Slide the sensor housing assembly over the top of the mounting arm and secure with the provided thumb screw.

Adjust each of the mounting arms to assure that the sensor is secured in a level position.

Slip the sensor debris cover onto top of sensor.

Mount the Controller

Remove the controller door from cabinet hinges.

Open the face panel by grasping the crescent shaped finger hold on the top right side of the cabinet.

Disconnect cable from back of panel.

Remove controller panel from cabinet hinge pins.

Drive a screw at eye level into the mounting wall surface. Leave approximately a 3/8" gap from wall.

Slide controller keyhole slot (located on back of the cabinet) onto the screw.

Secure controller by driving 3 screws into wall thru the holes located at bottom of controller.

Set current Month.

Set current Day of Month

Set current Year.

Set current Hour(assure AM or PM is correct).

Set current Minutes.

The ESP-SMT Smart Modular controller panel is designed to upgrade previously installed ESP-Modular controllers (ESP-SMT RETRO).

Connect Sensor Wire to Controller

Run provided wire or 18-2 AWG direct burial, UV rated wire from sensor to controller (200 ft. max).

Strip wire insulation approx 3/8" and insert leads into connector located on back of front panel (polarity not important).

Route the two wires through the provided channel and out through one of the knockouts, located in the bottom of the controller cabinet.

Remote Programming of Controller Panel

Insert 9-volt battery into the back of front panel to program the controller without AC power to the unit. Once completed, remove 9-volt battery from unit.

NOTE: All of the programmed info-rmation will be saved in non-volatile memory so you can pre-program the controller in advance of AC power availability.

Connect Field Wiring

Connect each valves separate power wire to the corresponding station (zone) terminal.

Connect a common wire to one of the leads on each valve.

Connect the other end of the common wire to the terminal location labeled COM.

NOTE: All 120V Power and Field Wiring (Valves & Pumps) is performed in the same manner as any other traditional time-based controller. For Pump, Master Valve and Control Valve Wiring Details, See User Manual – pages 61 to 62.

!

!

Install sensor in a location that receives afternoon sunin order to measure the daily high temperature (Southor West exposure is ideal).

Mount weather sensor at least six feet above grade.

Assure that sensor is free from obstructions to allow forcollection and accurate measurement of rainfall.

Do NOT install sensor in a location where spray from thesprinkler will collect in the sensor.

Do NOT install the sensor where it will be located in theshade during the hottest part of the day.

Do NOT install the sensor where rainfall will be blockedfrom entering the sensor funnel.

ESP-SMTCONTROLLER

SENSOR WIRE(MAX 200 FT.)

SET CURRENT DATE AND TIME

24 Mar 2009

10:16 AM

BACK NEXT

WIRES FROMSMT SENSOR

Enter SITE ZIP CODEEnter 1st WateringWindow

Select BLOCK WATERDAYS (if necessary)

Select ALLOWEDWATER DAYS

Review Entered Info(Change or Accept)

Enter GROW-INWatering Window

Enter 2nd WateringWindow

Select ZONE SETUPWIZARD method

Select SPRINKLER TYPE

Select SOIL TYPE

Select DEGREE SLOPE

Select SHADEFACTOR (all plants)

Enter PLANT DENSITY(non grass)

Enter PLANTMATURITY (all plants)

Select ZONE # Select PLANT TYPEEnter NEWLY PLANTEDschedule (if needed)

ENABLE zoneEnter PLANT WATERNEED (non grass)

Review Entered Info(Change or Accept)

Repeat process for alldesired Zones.

Rotate dial to INPUTZONE INFORMATIONposition

ALLOWED WATERINGBy Days of the Week

05:00 AM To 06:00

09:00 Grow-in: Daily

PM

AM

To

To

09:00 AM11:45

04:00

PM

PMCHANGE ACCEPT

Mo We Fr

SHADE FACTOR

Full Sun 25% Shade 50% Shade 75% Shade Full Shade

SELECTBACK

Zone 1

P/N: 637728-0103/31/11

Rotate dial to SET DATE & TIME position.

Rotate dial to CONFIGURE CONTROLLER position.

SET ALLOWED WATER TIME1st Watering Window

AM To 06:0006:00 PM

2nd Watering WindowOFF

NEXTBACK

GROW-IN WATER WINDOW

Water every day between

AM To 05:0009:00 PM

NEXTBACK

SOIL TYPE

Sand Loamy SandSandy Loam LoamClay Loam Silty ClayClay

Help SELECTBACK

Zone 2

SPRINKLER TYPE Zone 2Sprays Rotors

BubblersRotary Nozzle

Drip- OR -

Time-BasedSELECTBACK

SET ALLOWED WATER TIME1st Watering Window

AM To 09:0005:00 AM

PM To 11:4506:00 PMNEXTBACK

2nd Watering WindowON

CYCLE/SOAKSelect Slope in Deg.0-2° 3-4°5-7° 8°-upCycle/Soak AutomaticMax Cycle MinMin Soak

(6)(40) Min

Zone xx

NEXTBACK