Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

Upload: sharyl-lambert

Post on 14-Dec-2015

218 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

RPC cablingRPC cabling

• HV & LV cables

• Signal cables

• Position and composition of racks in UXC and USC

Page 2: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

HV cable layout (from UXC55 vs USC55)HV cable layout (from UXC55 vs USC55)

Conductor @ 15 KV(DC)with individual insulating sheath

Braided shield

Signal return

Required characteristicCERN safety instruction IS23:•Flame retardant (IEC 60332-3 Cat. C)•Zero halogene (IEC 60754-1)•Smoke density (IEC 61034)•Corrosiveness of combustion gases (IEC 60754-1)•Maximum current per conductor: 500 uA•Maximum voltage per conductor: 15 KV-DC

External sheath

Internal sheath

Page 3: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

HV cables characteristicsHV cables characteristics

• Multiconductor cable 8 x (3x0.22) H2M1 Halogene Free 15 kV cc (from patch panels towards tower to patch panel on USC)– External diameter 26.2 mm (nominal)– Weight (indicative) 826 g/m

• Cable 1 x (3x0.22) H2M1 Halogene Free 15 kV cc (from detector towards patch panels on towers)– External diameter 7.7 mm (nominal)– Weight (indicative) 82 g/m

• Manufacturer: NOVACAVI

Page 4: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

LV cable characteristicsLV cable characteristics

• Cable 12 x 0.75 (RB2/3 case):– Braided shield: copper

– External diameter (nominal): 10.1 mm

– Weight (indicative): 175 g/m

• Cable 8 x 0.75 (RB2/2 case):– Braided shield: copper

– External diameter (nominal): 9.0 mm

– Weight (indicative): 156 g/m

• Manufacturer: NOVACAVI

Page 5: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

Signal cable characteristicsSignal cable characteristics

• 20 twisted pairs cable• Very low skew cable (1-2 ns between pairs for 25 m max length)• Conductor cross section: 28 AWG• Insulator: PE• Global shield: tinned copper braid• External shield: PE• Total external diameter: 12-13 mm• Rated voltage: 10 V (used for LVDS signal transmission)• Operating temperature: 0°/+60°C• Characteristic impedance: 110 (10%)• CERN safety instruction IS23 compliant:

– Flame retardant (IEC 60332-3 Cat. C)– Zero halogene (IEC 60754-1)– Smoke density (IEC 61034)– Corrosiveness of combustion gases (IEC 60754-1)

• Competitor manufacturers: Kabelwerk EUPEN - NOVACAVI

Page 6: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

Possible cabling layoutPossible cabling layout

Drawn by L. Roscilli

Page 7: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

Possible cabling layoutPossible cabling layout

Drawn by L. Roscilli

Page 8: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

Barrel RPC: sector cables (except sectors 4-9-10-11)

Barrel RPC: sector cables (except sectors 4-9-10-11)

RB2_OUT

RB2_IN

RB1_OUT

RB1_IN

RB3 RB3

RB4 RB4

6 LV 8 HV

To balconies

12

78 SGN6 DCS

To LBBOX

12

18 (12)

12 (18)

12

12

17p

17p

110p (17p)

17p

17p

Wheel 0, ±1 (Wheel ±2 )

18w

18w

112w (18w)

18w

18w

18w (112w) 17p (110p)

Page 9: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

Barrel RPC: sector cables (sector 4)Barrel RPC: sector cables (sector 4)

RB2_OUT

RB2_IN

RB1_OUT

RB1_IN

RB3 RB3

RB4

7 LV 10 HV

To balconies

12

90 SGN7 DCS

To LBBOX

12

18(12)

12(18)

12

RB4 RB4 RB4

Wheel 0, ±1 (Wheel ±2 )

17p

17p

110p (17p)

17p

17p

17p (110p)

17p

18w

18w

112w (18w)

18w

18w

18w (112w)

18w

12

12

Page 10: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

Barrel RPC: sector cables (sector 10)Barrel RPC: sector cables (sector 10)

RB2_OUT

RB2_IN

RB1_OUT

RB1_IN

RB3 RB3

RB4 RB4

7 LV 8 HV

To balconies

12

86 SGN7 DCS

To LBBOX

12

12

10

Wheel 0, ±1 (Wheel ±2 )

18w

18w

112w (18w)

18w

18w

18w (112w)

18w

18(12)

12(18)

17p

17p

110p (17p)

17p

17p

17p (110p)

17p

10

Page 11: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

Barrel RPC: sector cables (sectors 9-11)Barrel RPC: sector cables (sectors 9-11)

RB2_OUT

RB2_IN

RB1_OUT

RB1_IN

RB3 RB3

RB4

6 LV 7 HV

To balconies

12

72 SGN6 DCS

To LBBOX

12

12

6

Wheel 0, ±1 (Wheel ±2 )

18w

18w

112w (18w)

18w

18w

18w (112w)

18(12)

12(18)

17p

17p

110p (17p)

17p

17p

17p (110p)

Page 12: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

Numbers and lengthsNumbers and lengthsUpdated by F. Montecassiano

Page 13: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

Numbers and lengthsNumbers and lengthsUpdated by F. Montecassiano

Page 14: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

Cables length specification (Wheel 0/ Z-)Cables length specification (Wheel 0/ Z-)

updated by L. Roscilli

Page 15: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

Cables length specification (Wheel 0/ Z+)Cables length specification (Wheel 0/ Z+)

updated by L. Roscilli

Page 16: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

Rack composition in USCRack composition in USC

EASY4000

EASY3000

EASY4000

EASY3000

HV Patch Panel

1. SY1527:9 or 11 A1676 Branch Controllers

1. EASY crates2. HV modules (A3512):

7 modules/crate

Full Option:1020 HV channels

Chamber Option:480 HV channels

Station Option:360 HV channels

170 HV modules

25 EASY crates+ 1 SY1527 + 20 HV patch panel

80 HV modules

12 EASY crates+ 1 SY1527 + 20 HV patch panel

60 HV modules

9 EASY crates+ 1 SY1527 + 20 HV patch panel

+

Page 17: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

Rack position in USCRack position in USC

Page 18: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

Rack composition in UXCRack composition in UXC

Calculation per quadrant (Barrel)• 3 LV modules (A3003)/quadrant (6 EASY crate slots)• Current absorption calculations:

– 2 Lbboxes x 13 LBs = 26 LBs– 1 Lbbox x 15 LBs = 15 LBs– 41 LBs/quadrant– Current absorption: 14A/LB (estimation)– 14A x 41 LBs = 574 A/quadrant– We need 6 A3100 CAEN LV module (4 slots width each)– We need a total of 24 slots 1 + 1/5 EASY crates per

tower– This fit with the 2 x 6U crates foreseen for RPC.

Page 19: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

Rack composition in UXC towersRack composition in UXC towers

Page 20: Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

PaolucciINFN-Napoli

PaolucciINFN-NapoliMuon Annul Review

Cern 15 September 2003

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

ConclusionsConclusions

• We are ready for asking a cable PRR– we are just collecting all necessary documentations

• Before the end of this year we start tenders– this implies to know exactly total lengths

• Open issues:– Cable path (to be approved very soon)