Catalogue HY17-8249/USMarch 2004
HydraulicMotor/PumpSeries F11/F12 zp12
Fixed Displacement zp11
Conversion factors1 kg ............................................................... 2.20 lb1 N.............................................................. 0.225 lbf1 Nm........................................................ 0.738 lbf ft1 bar .............................................................14.5 psi1 l ....................................................0.264 US gallon1 cm3 .......................................................0.061 cu in1 mm ........................................................... 0.039 in9/5°C + 32 .......................................................... 1 °F
3 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
Catalogue HY17-8249/US
Content
Content PageGeneral information ................................................ 4F11 cross section ................................................... 4F12 cross sections ................................................. 5Specifications ......................................................... 6Ordering codesF11-CETOP ............................................................ 7F11-ISO .................................................................. 8F11-SAE ................................................................. 9F12-ISO ................................................................ 10F12-Cartridge ....................................................... 11F12-SAE ............................................................... 12Prefered versions F11/F12 ................................... 13Technical informationBearing life ........................................................... 14Bearing life calculation.......................................... 14Required information ............................................ 14Noise level ............................................................ 15Efficiency .............................................................. 15Selfpriming speed and required inlet pressure ..... 16Installation dimensionsF11-5 CETOP ....................................................... 17F11-10 CETOP ..................................................... 18F11-14 CETOP ..................................................... 19F11-19 CETOP ..................................................... 20F11-14 ISO ........................................................... 21F11-14 SAE .......................................................... 22F11-19 SAE .......................................................... 23F12-30, -40, -60, -80 and -110 ISO ................ 24-25F12-30, -40, -60, -80 and -110 Cartridge ........ 26-27F12-30, -40, -60, -80 and -110 4 bolt flange .... 28-29F12-30, -40, and -60 2 bolt flange ................... 30-31F11-150 CETOP ................................................... 32F11-150 SAE ........................................................ 33F11-250 SAE ........................................................ 34Technical informationF11 saw motors .................................................... 35F11 fan motors ..................................................... 35F12 integrated flushing valve ................................ 36F12 accessory valve blocks .................................. 36Type BT brake valve ............................................. 37Type SR pressure relief/make-up valve ................ 37Type SV pressure relief valve ............................... 38Speed sensor ....................................................... 38F12 main port suction fittings ............................... 39Suction fittings ...................................................... 39Suction fitting kits ................................................. 39Split-flange kits ..................................................... 39Installation information ......................................... 40Direction of rotation .............................................. 40Hydraulic fluids ..................................................... 40Operating temperature ......................................... 40Installation informationViscosity ............................................................... 41Filtration ............................................................... 41Case pressure ...................................................... 41Case drain connections ........................................ 42Before start-up ..................................................... 42
4 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F11 cross section
1. Barrel housing
2. Valve plate
3. Cylinder barrel
4. Guide spacerwith O-rings
5. Timing gear
6. Roller bearing
7. Bearing housing
8. Shaft seal
9. Output/input shaft
10. Piston with laminatedpiston ring 10
1 2 3 4 5 6 7 8 9
F11 and F12 are bent axis, fixed displacement heavy-duty motor/pump series. They can be used in numer-ous applications in both open and closed loop circuits.• Series F11 is available in the following frame sizes
and versions:- F11-5, -10, -14, 19 and -150 with CETOP mounting
flange and shaft end- F11-14 with ISO flange and shaft- F11-14, -19, -150 and -250 with SAE flange and
shaft• Series F12 conforms to current ISO and SAE
mounting flange and shaft end configurations. A verycompact cartridge version is also available.
• Thanks to the unique spherical piston design, F11/F12motors can be used at unusually high shaft speeds.Operating pressures to 480 bar provides for the highoutput power capability.
• The 40° angle between shaft and cylinder barrelallows for a very compact, lightweight motor/pump.
• The laminated piston ring offers importantadvantages such as low internal leakage and thermalshock resistance.
• The pump version has highly engineered valve platesfor increased selfpriming speed and low noise,available with left and right hand rotation.
• The F11/F12 motors produce very high torque atstart-up as well as at low speeds.
• Our unique timing gear design synchronizes shaftand cylinder barrel, making the F11/F12 very tolerantto high 'G' forces and torsional vibrations.
• Heavy duty roller bearings permit substantial externalaxial and radial shaft loads.
• The F11's and F12's have a simple and straight-forward design with very few moving parts, makingthem very reliable motors/pumps.
• The unique piston locking, timing gear and bearingset-up as well as the limited number of parts add upto a very robust design with long service life and,above all, proven reliability.
Catalogue HY17-8249/US
General information
5 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
1 2 3 4 5 6 7 8 9
1 2 3 10 4 5 6 7 8 9
11
F12 cross sections
1. Barrel housing
2. Valve plate
3. Cylinder barrel
4. Piston with piston ring
F12-30, -40, -60 and -80(F12-60 shown)
5. Timing gear
6. Tapered roller bearings
7. Bearing housing
8. Shaft seal
9. Output/input shaft
10. Port E (F12-110)
11. Needle bearings (F12-110)
F12-110
Legend:
Catalogue HY17-8249/US
General information
6 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
Frame size F11-5 -10 -14 -19 F12-30 -40 -60 -80 -110 F11-150 -250
Displacement [cm3/rev] 4.9 9.8 14.3 19.0 30.0 40.0 59.8 80.4 110.1 150 242[cu in/rev] 0.30 0.60 0.87 1.16 1.83 2.44 3.65 4.91 6.72 9.15 14.8
Operating pressuremax intermittent1) [bar] 420 420 480 480 420 420
[psi] 6 000 6 000 7 000 7 000 6 000 6 000
max continuous [bar] 350 350 420 420 350 350[psi] 5 000 5 000 6000 6000 5 000 5 000
Motor operating speed [rpm]max intermittent1) 12 000 11 000 10 000 9 000 7 100 6 400 5 600 5 200 4 700 3 000 2 700
max continuous 10 800 9 900 9 000 8 100 5 600 5 000 4 300 4 000 3 600 2 600 2 400
min continuous 50 50
Max pump selfpriming speed2)
L or R function; max [rpm] 4 600 4 200 3 900 3 500 3150 2870 2500 2300 2290 1 700 1 500
Motor input flowmax intermittent1) [l/min] 58 108 143 171 213 256 335 418 517 450 650
[gpm] 15.3 28.5 37.8 45.2 56.3 67.6 88.5 110.4 136.6 119.0 172.8
max continuous [l/min] 52 97 128 153 168 200 257 322 396 390 580[gpm] 13.7 25.6 33.8 40.4 44.4 52.8 67.9 85.1 104.6 103.0 153.6
Main circuit temp.3), max [°C] 80 80[°F] 175 175
min [°C] -35 -35 -30 -35 -35 -35 -35 -35[°F] -31 -31 -22 -31 -31 -31 -31 -31
Mass moment of inertia(x10-3) [kg m2] 0.16 0.39 0.42 1.1 1.7 2.9 5 8.4 11.2 40 46(x10-2) [lbft2] 0.38 0.92 1.00 2.61 4.03 6.88 11.86 19.93 26.58 94.92 109.16
Weight [kg] 5 7.5 8.3 11 12 16.5 21 26 36 70 77[lb] 11 16.5 18.8 24 26 36 46 57 79 154 170
1) Intermittent: max 6 seconds in any one minute.2) Selfpriming speed valid at sea level.3) See also installation information, operating temperature.
Catalogue HY17-8249/US
Specifications
Torque (M)
M = [Nm]
Basic formulas for hydraulic motors
Flow (q)
q = [l/min]
Power (P)
P = [kW]
D x n 1000 x ηv
D x ∆p x ηhm 63
q x ∆p x ηt 600
D - displacement [cm3/rev]n - shaft speed [rpm]
ηv - volumetric efficiency∆p - differential pressure [bar]
(between inlet and outlet)ηhm - mechanical efficiency
ηt - overall efficiency(ηt = ηv x ηhm)
7 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F11-CETOP
x: Available (x): Optional – : Not available1) Internal drain2) BSP threads3) NBR - Nitrile rubber4) FPM - Fluor rubber
Catalogue HY17-8249/US
Ordering codes
Frame sizeCode Displacem.
(cm3/rev)5 4.9
10 9.814 14.319 19.0
150 150.0
Frame size 5 10 14 19 150Code Main ports
B BSP threads x x x x -R With anti-cavitation
valve; clockwise rot’n2) - x x x -L With anti-cavitation
valve; counter clockw.2) - x x x -U SAE, UN threads (x) (x) - (x) -F SAE 6000 psi flange - - - - x
Frame size 5 10 14 19 150Code Function
M Motor x x - x xH Motor, high pressure x x x x xQ Motor, silent (x) (x) - (x) (x)J Motor, clockwise rot'n1) (x) (x) - (x) (x)G Motor, counter clockw.1) (x) (x) - (x) (x)R Pump, clockwise rot'n x x x x xL Pump, counter clockw. x x x x x
Frame size 5 10 14 19 150Code Mounting flange
C CETOP flange x x x x xW Saw motor flange - x x x -
Frame size 5 10 14 19 150Code Shaft seal
N NBR3), low pressure x x - x xH NBR3), high pressure x x - x xE FPM4), low pressure,
high temperature x x x x xV FPM4), high pressure,
high temperature - x x x -
Frame size 5 10 14 19 150Code Shaft
K Metric key x x x x xD Spline, DIN 5480 (x) (x) (x) (x) (x)
Version number(assigned for specialversions)
F11 — — —— — — —
Frame
size
Function Main
ports
Mounting
flange
Shaft
seal
Shaft Version
number
Option
page 36
Option
page 38
Frame size 5 10 14 19 150Code Option
S With speed sensor - - x x -P Prepared for speed
sensor - - x x -
OptionNone
Pump
Motor
8 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F11-ISO
x: Available (x): Optional – : Not available1) FPM - Fluor rubber
Catalogue HY17-8249/US
Ordering codes
Frame sizeCode Displacem.
(cm3/rev)14 14.3
Frame size 14Code Main ports
F SAE 6000 psi flange x
Frame size 14Code Function
H Motor, high pressure xR Pump, clockwise rot'n xL Pump, counter clockw. x
Frame size 14Code Mounting flange
I ISO flange x
Frame size 14Code Shaft seal
E FPM1), low pressure,high temperature x
V FPM1), high pressure,high temperature x
Frame size 14Code Shaft
K Metric key xD Spline, DIN 5480 (x)
Version number(assigned for specialversions)
F11 — — —— — — —
Frame
size
Function Main
ports
Mounting
flange
Shaft
seal
Shaft Version
number
Option
page 36
Option
page 38
Frame size 14Code Option
S With speed sensor xP Prepared for speed
sensor x
OptionNone
Pump
Motor
9 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
Catalogue HY17-8249/US
Ordering codes
Pump
Motor
F11-SAE
x: Available (x): Optional – : Not available1) Internal drain2) Metric thread3) BSP threads4) NBR - Nitrile rubber5) FPM - Fluor rubber
Frame sizeCode Displacem.
(cm3/rev)14 14.319 19.0
150 150.0250 242.0
Frame size 14 19 150 250Code Main ports
U SAE, UN threads x x - -B BSP threads - (x) - -F SAE 6000 psi flange2) - - x xR With anti-cavitation
valve; clockwise rot’n3) x x - -L With anti-cavitation
valve; counter clockw.3) x x - -
Frame size 14 19 150 250Code Function
M Motor - x x -H Motor, high pressure x x x -Q Motor, silent - (x) (x) xJ Motor, clockwise rot'n1) - (x) (x) -G Motor, counter clockw.1) - (x) (x) -R Pump clockwise rot'n x x x xL Pump counter clockw. x x x x
Frame size 14 19 150 250Code Mounting flange
S SAE flange x x x x
Frame size 14 19 150 250Code Shaft seal
N NBR4), low pressure - x x xH NBR4), high pressure - x x xE FPM5), low pressure,
high temperature x x x xV FPM5), high pressure,
high temperature x x - -
Frame size 14 19 150 250Code Shaft
T SAE key x x x -S SAE spline (x) (x) (x) (x)K Metric key - - - xF SAE spline - - - (x)
Version number(assigned for specialversions)
F11 — — —— — — —
Frame
size
Function Main
ports
Mounting
flange
Shaft
seal
Shaft Version
number
Option
page 36
Option
page 38
Frame size 14 19 150 250Code Option
S With speed sensor x x - -P Prepared for speed
sensor x x - -
OptionNone
10 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
Catalogue HY17-8249/US
Ordering codes
F12-ISO
Frame sizeCode Displacem.
(cm3/rev)30 30.040 40.060 59.880 80.4
110 110.1
Frame size 30 40 60 80 110Code Option
S With speed sensor x x x x xP Prepared for speed
sensor x x x x x
Frame size 30 40 60 80 110Code Main ports
F ISO flange x x x x x
Frame size 30 40 60 80 110Code Shaft seal
H NBR1), high pressure x x x x xN NBR1), low pressure x x x x xV FPM2), high temperature, x x x x x
high pressure
Frame size 30 40 60 80 110Code Shaft
D DIN spline Standard x x x x xZ Optional (x) (x) - (x) -K Metric key Standard x x x x xP Optional (x) - - - -
Frame size 30 40 60 80 110Code OptionL01 Integr. flushing valve x x x x -3)
Frame size 30 40 60 80 110Code Mounting flange
I ISO flange x x x x x
Frame size 30 40 60 80 110Code Function
M Motor x x x x x
Pump:L counter clockw. x x x x xR clockwise x x x x x
x : Available (x) : Optional – : Not available1) NBR - Nitrile rubber2) FPM - Fluor rubber3) F12-110: Accessory valve block (page 36)
Version number(assigned forspecial versions)
F12 — — —— — — —
Frame
size
Function Main
ports
Mounting
flange
Shaft
seal
Shaft Version
number
Option
page 36
Option
page 38
11 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F12-Cartridge
Catalogue HY17-8249/US
Ordering codes
F12 — — —— — — —
Frame
size
Function Main
ports
Mounting
flange
Shaft
seal
Shaft Version
number
Option
page 36
Option
page 38
Frame sizeCode Displacem.
(cm3/rev)30 30.040 40.060 59.880 80.4
110 110.1
Frame size 30 40 60 80 110Code Function
M Motor x x x x x
Frame size 30 40 60 80 110Code Main ports
F ISO flange x x x x x
Frame size 30 40 60 80 110Code Mounting flangeC Cartridge x x x x x
Frame size 30 40 60 80 110Code Shaft seal
H NBR1), high pressure x x x x xN NBR1), low pressure x x x x xV FPM2) high temperature, x x x x x
high pressure)
Frame size 30 40 60 80 110Code Shaft
C DIN spline Standard x x x x xK Metric key Standard x - x x -X " " Optional - (x) - - -
Frame size 30 40 60 80 110Code OptionL01 Integr. flushing valve x x x x -3)
Frame size 30 40 60 80 110Code Option
S With speed sensor x x x x xP Prepared for speed
sensor x x x x x
x : Available (x) : Optional – : Not available1) NBR - Nitrile rubber2) FPM - Fluor rubber3) F12-110: Accessory valve block (page 36)
Version number(assigned forspecial versions)
12 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
x : Available (x) : Optional – : Not available1) NBR - Nitrile rubber2) FPM - Fluor rubber3) F12-110: Accessory valve block (page 36)
Catalogue HY17-8249/US
Ordering codes
F12 — — —— — — —
F12-SAE
Frame sizeCode Displacem.
(cm3/rev)30 30.040 40.060 59.880 80.4
110 110.1
Frame
size
Function Main
ports
Mounting
flange
Shaft
seal
Shaft Version
number
Option
page 36
Option
page 38
Frame size 30 40 60 80 110Code Option
S With speed sensor x x x x xP Prepared for speed
sensor x x x x x
Frame size 30 40 60 80 110Code Main ports
S SAE flange x x x x xU SAE, UN threads (x) (x) (x) - (x)
Frame size 30 40 60 80 110Code Shaft seal
H NBR1), high pressure x x x x xN NBR1), low pressure x x x x xV FPM2), high temperature, x x x x x
high pressure
Frame size 30 40 60 80 110Code Shaft
S SAE spline Standard x x x x xU " " Optional - - - (x) -T SAE key Standard x x x x x
Frame size 30 40 60 80 110Code OptionL01 Integr. flushing valve x x x x -3)
Frame size 30 40 60 80 110Code Mounting flange
S SAE 4 bolt x x x x xT SAE 2 bolt x x x - -
Frame size 30 40 60 80 110Code Function
M Motor x x x x x
Pump:L counter clockw. x x x x xR clockwise x x x x x
Version number(assigned forspecial versions)
13 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
Prefered versions F11/F12 catalogueF11Ordering Codes Part numberF11-005-MB-CN-K 3703665F11-005-MB-CH-K 3707249F11-005-HU-CH-K 3707308F11-010-MB-CN-K 3703603F11-010-MB-CH-K 3706030F11-010-HU-CH-K 3707310F11-014-HB-CE-K 3783201F11-014-HB-CV-K 3782830F11-019-MB-CN-K 3703516F11-019-MB-CH-K 3707893F11-150-MF-CN-K 3703468F11-150-MF-CH-K 3707008F11-150-HF-SH-S 3707325F11-250-QF-SH-F 3706440F11-250-QF-SH-K 3795858
F12Ordering Codes Part numberF12-30-MF-IH-D 3799843F12-30-MF-IH-K 3799844F12-30-MS-SH-S 3799851F12-30-MS-TH-S 3799616F12-40-MF-IH-D 3799525F12-40-MF-IH-K 3799526F12-40-MS-SH-S 3799532F12-40-MS-SH-T 3799533F12-40-MS-TH-S 3799617F12-60-MF-IH-D 3799988F12-60-MF-IH-K 3799989F12-60-MS-SH-S 3799998F12-60-MS-TH-S 3799618F12-80-MF-IH-D 3780767F12-80-MF-IH-K 3780772F12-80-MS-SH-S 3780783F12-110-MF-IH-D 3781530F12-110-MF-IH-K 3781534F12-110-MS-SH-S 3781542
Catalogue HY17-8249/US
Ordering codes
14 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
Life expectancy(logarithmic scale)
Othercauses
Bearingfatigue
Rotating groupfatigue and wear
Systempressure
Hydraulic unit life versus system pressure.
Bearing life
General informationBearing life can be calculated for that part of the load/life curve (shown below) that is designated 'Bearingfatigue'. 'Rotating group fatigue and wear' and 'Other'caused by material fatigue, fluid contamination, etc.should also be taken into consideration when estimat-ing the service life of a motor/pump in a specific appli-cation.Bearing life calculations are mainly used when compar-ing different frame sizes. Bearing life, designated B10(or L10), is dependent of system pressure, operatingspeed, external shaft loads, fluid viscosity in the case,and fluid contamination level.The B10 value means that 90% of the bearings survive,at a minimum, the number of hours calculated. Statisti-cally, 50% of the bearings will survive at least fivetimes the B10 life.
Bearing life calculationAn application is usually governed by a certain duty orwork cycle where pressure and speed vary with timeduring the cycle.In addition, bearing life depends on external shaftforces, fluid viscosity in the case and fluid conta-mination.Parker Hannifin (Mobile Controls Division) has acomputer program for calculating bearing life and willassist in determining F11 or F12 motor/pump life in aspecific application.
Required informationWhen requesting a bearing life calculation from ParkerHannifin (Mobile Controls Division), the followinginformation (where applicable) should be provided:- A short presentation of the application- F11 or F12 size and version- Duty cycle (pressure and speed versus time
at given displacements)- Low system pressure- Case fluid viscosity- Life probability (B10, B20, etc.)- Operating mode (pump or motor)- Direction of rotation (L or R)- External shaft loads- Fixed or rotating radial load- Distance between flange and radial load- Angle of attack (α) as defined below
The direction (a) of the radial load is positive in thedirection of rotation as shown.To obtain maximum bearing life, the radial load should,in most cases, be located approximately at 170°(motor; R.H. rot'n) or 190° (pump; R.H rot'n).
Catalogue HY17-8249/US
Technical information
F Fα
15 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
Noise level
Series F11/F12 feature low noise levels from low tohigh speeds and pressures.As an example, the diagram to the right shows thenoise level of an F12-30.The noise level is measured in a semi-anechoic room,1 m behind the unit.The noise level for a particular motor/pump may vary±2 dB(A) compared to what is shown in the diagram.
NOTE: Noise information for F11/F12 framesizes are available from Parker Hannifin.
Efficiency
Because of its high overall efficiency, driving a motor/pump from series F11/F12 requires less fuel or electricpower. Also, it allows the use of a small reservoir andheat exchanger, which in turn reduce cost, weight, andinstallation size.The diagrams to the right shows volumetric andmechanical efficiencies of an F12-30.
Contact Parker Hannifin for efficiency information on aparticular F11/F12 frame size that is being considered.
Catalogue HY17-8249/US
Technical information
Volumetric efficiency.
Mechanical efficiency.
100%
90%
80%
0 1000 2000 3000 4000 Speed [rpm]
100%
90%
80%
0 1000 2000 3000 4000 Speed [rpm]
F12-30(motor)
F12-30(motor)
3000 psi
6000 psi
6000 psi
3000 psi
Noise level[dB(A)]
90
85
80
75
70
65
0 1000 2000 3000 4000 5000 Pressure [psi]
5000 rpm
3500 rpm
2000 rpm
F12-30 (M, L or R function)
16 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
1000 2000 3000 4000 Speed [rpm]
F12-110 -80 -60 -40 -30
1000 2000 3000 4000 Speed [rpm]
F12-110 -80 -60 -40 -30
F12-L or -R
F12-M
Inlet press.[psi]
30
20
10
0
5 in. Hg vacuum
Inlet press.[psi]
30
20
10
0
5 in. Hg vacuum
Inletpressuregauge
Function L or R M H
F11-5 4600 3800 3200F11-10 4200 3100 2700F11-14 3900 - 3200F11-19 3500 2400 2100F11-150 1700 1300 1100F11-250 1500 950 -
Selfpriming speed and required inletpressure
Series F11
In pump applications, the F11 with function L (counterclockwise rotation) or R (clockwise rotation) is normallyused. The L and R (pump) provide the highest self-priming speeds (see table) as well as the lowest noiselevel. The M (motor) function can also be used as apump, in either direction, but at a lower selfprimingspeed.Operating above the selfpriming speed (refer toDiagram 1) requires increased inlet pressure.As an example, at least 1.0 bar is needed when operat-ing the F11-19-M as a pump at 3500 rpm. An F11 withH function, used as a motor (e.g. in a hydrostatictransmission), may sometimes operate as a pump atspeeds above the selfpriming speed; this requiresadditional inlet pressure.Insufficient inlet pressure can cause pump cavitationresulting in greatly increased pump noise and deterio-rating performance.
Series F12
When operating the F12 as a pump (with L or R valveplate) above the selfpriming speed, the inlet must bepressurized. Increased noise and deteriorating per-formance may otherwise be experienced.Diagrams 2 and 3 show required pump inlet pressurevs. shaft speed.The F12 motor (type M valve plate) sometimes oper-ates as a pump e.g. when used in a propel transmis-sion and the vehicle is going downhill.Minimum required inlet pressure versus shaft speed isshown in the diagrams.
Diagram 2. Min. required pump (F12-L or -R) inlet press.
Diagram 3. Min. required motor (F12-M) inlet pressure.
Diagram 1. Min required inlet pressure (F11-19).
NOTE: Diagrams 1, 2 and 3 are validat sea level.
Catalogue HY17-8249/US
Technical information
H
M
L, R
1000 2000 3000 4000 Speed [rpm]
Inlet pressure[psi]
30
20
15
10
0
F11-19
5 in. Hg vacuum
17 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F11-5(CETOP versions)
Catalogue HY17-8249/US
Installation dimensions
3.31 max
1.50
Main port ABSP ½"
Main port B BSP ½"
Drain port CBSP ¼"
2.56
0.20 1.87
3.48
2.13
1.57 1.18
0.20
40˚
0.35
0.51
5.28 max
Ø0.70900.7085
Ø3.14963.1478
Ø0.80 min
Approx.center of
gravity
3.78 max
2.09
4.47
0.31
0.47min
0.98
0.35
0.79
M6*
0.81
Ø0.43 (x2)
Ø5.00max
3.94
Drain port DBSP ¼"
Flange C
Key shaft K
Key 6x6
R 0.03 R 0.02
W18x1,25x13x9g
Type D spline shaft (DIN 5480)
Mounting flange C
* Metric thread
18 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F11-10(CETOP versions)
Catalogue HY17-8249/US
Installation dimensions
3.70 max
1.81
Main port ABSP ¾"
Main port B BSP ¾"
Drain port CBSP 3/8"
3.11
0.43 2.09
3.98
2.48
1.97 1.38
0.28
40˚
0.35
0.55
6.14 max
Ø0.78780.7872
Ø3.93703.9349
Ø0.91 min
Approx.center of
gravity
4.57 max
2.24
5.24
0.31
0.47min
1.18
0.35
0.87
M6*
0.89
Ø0.51 (x2)
Ø5.98max
4.92
Drain port DBSP ¼"
Flange C
Key shaft K
Key 6x6
R 0.03 R 0.02
W20x1.25x14x9gSpline shaft D (DIN 5480)
Mounting flange C
* Metric thread
19 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F11-14(CETOP versions)
Catalogue HY17-8249/US
Installation dimensions
BA
25˚
3.94
5.876.18max
0.37
1.65 1.38
0.55
0.14
4.02
1.772.83
2.09
1.26
2.32
R 0.03
5.51
Ø0.51 (x2)
4.49
5.91
39˚ (x4)
0.31
Ø1.06
Ø0.98460.9841
4.02
1.81
1.18
0.31
1.10
Ø0.9744
M8x0.63
Ø3.93703.9349
R 0.02
1.02
Anticavitation valve(left or right hand optional;right hand shown)
Main port A(BSP 3/4”-A)
W 25x1.25x18x9g
Type D spline
shaft (DIN 5480)
Drain port C(BSP 3/8”-A)
Speed sensor(optional)
Flange C
Drain port D(BSP 3/8”-A)
Type K key shaft
CCW CW
Type C mounting flange
Key 8x7x35
Main port B (BSP 3/4”-A)
5.24
20 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F11-19(CETOP version)
3.46
0.43
2.484.49 max
2.13
Drain port DBSP 3/8"
Main port ABSP ¾" Main port B
BSP ¾"
Drain port CBSP 3/8"
Flange C
Key shaft K
Key 8x7x35
R 0.05maxR 0.04
max
Ø1.11 min
Ø0.98460.9841 Ø4.4094
4.4073
2.28
0.981.65
6.50 max1.14
0.98
1.10
0.91
5.43
3.940.63
0.39
45˚
4.96
Ø6.69max
Ø0.55 (x2)
3.42
5.51
Mounting flange C
Approx.center ofgravity
0.63min
M8*
1.10
W25x1.25x18x9gSpline shaft D (DIN 5480)
* Metric thread
Catalogue HY17-8249/US
Installation dimensions
21 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F11-14(ISO versions)
Catalogue HY17-8249/US
Installation dimensions
BA
3.98 Main ports M26(metric thread;
depth 0.47;ISO 9974-1)
Drain port M26(metric thread;
depth 0.47;ISO 9974-1)
Drain port M26(metric thread;
depth 0.47;ISO 9974-1)
1.81
4.84
1.18
1.10
Ø0.974
W25x1.235x18x9g)Type D spline shaft (DIN 5480)
R 0.02 max
0.260.73
0.47
M8 (metric thread)0.63 deep
Ø3.1496/3.1478
0.31
Ø1.06
Ø0.9846/0.9841
1.10
3.54
5.47
5.79(max)
0.83
1.651.38
Type K key shaft
Flange I(ISO 3019/2)
0.14
2.866
4.02
1.77 Speed sensor(optional)
2.09
25
0.41 (x4)Ø0.35 (x4)
Ø0.35 (x4)
3.74
CCW CW
Type I mounting flange (ISO 3019/2)
Key 8x7x35
22 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F11-14(SAE versions)
Catalogue HY17-8249/US
Installation dimensions
Ø0.94 (x2)
0.250
Ø1.06
Ø1.000/0.998
4.02
0.95
1.30
0.31
1.50 1.25
5.94
0.67(x2)
6.21 (max)
5.75
29˚ (x4)
4.02
1.77 Speed sensor(optional)
2.09
25˚
Ø0.57 (x2)
4.72
6.85 (max)
BA
R 10.24 (x2)
CCW CWR 0.55 (x4)
(0.31)
3.98
1.81
5.24
1.18
Ø3.15
1.11
5/16"-24 UNF-2B(0.63 deep)
R 0.02
0.37
Ø4.000/3.998
Main ports 11/16"-12 UN,O-ring boss; SAE J514d
Drain port 9/16" UNF;O-ring boss; SAE J514d
Type S spline shaft13 T, 16/32 DP
(SAE J498b; class 1,30 involute spline,flat root, side fit)
Drain port 9/16" UNF,O-ring boss; SAE J514d
Type T key shaft
Key8x7x35
Type S mounting flange SAE 'B' ( SAE J744c)
23 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F11-19(SAE version)
Catalogue HY17-8249/US
Installation dimensions
3.46
0.43
2.48
Drain port D9/16"-18
Flange SKey shaft TSAE 'B-B'(SAE J744c)
Key 1/4"x1/4"x11/4"
R 0.04R 0.03
Ø1.11 min
Ø1.0000.998
2.91
0.31
1.50
7.13 max
0.31
1.30
4.61
0.67
Spline shaft S (SAE J498b)
Approx.center ofgravity
SAE 'B' (13T, 16/32 DP;class 1, flat root, side fit)
2.13Main port A11/16"-12*
Main port B11/16"-12*
Drain port C9/16"-18
Ø4.0003.998
Ø6.93max
1.14
0.38
6.10
30˚
Ø0.57 (x2)
Mounting flange SSAE 'B' (SAE J744c)
0.63min
5/16"/24**
1.11
R 0.55 1.02
5.75
4.84
4.49 max
* O/ring boss (SAE J514d)** UNC thread
24 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F12-30, -40, -60, -80 and -110(ISO versions)
Catalogue HY17-8249/US
Installation dimensions
A1
A1
A3
B3
K3
L3
C3
A2
G2
J2
N2G3
H3
J3
F3
S2
Seetable
D3 (thread)
Ø E3
P2
L2 Type Iflange
M2D2
Ø E2
Ø F2
H2(±0.02)
K2
Port C1)
B2
C2
Port D Port A Port B
Ø D1 (x4)
B1
C1
T3
Type I mounting flange(ISO 3019/2)
Type D (Z) spline shaft
Type K (P)key shaft
Port E (third drain port)
F12-110 barrel housing(ISO/cartridge version)
NOTE: Type Z hasno thread
Flushingvalve
(optional)
Speedsensor
(optional)
1) Inspection/ drain port
Shown: F12-80
Q2
R2
25 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
Catalogue HY17-8249/US
Installation dimensions
Dim. F12-30 F12-40 F12-60 F12-80 F12-110
A1 3.48 4.46 4.46 5.01 5.57B1 4.65 5.75 5.75 6.22 7.09C1 4.65 5.59 5.67 6.10 7.09D1 0.43 0.53 0.53 0.53 0.71
A2 3.94 4.33 4.92 5.32 5.71B2 2.32 2.56 2.76 3.05 3.35C2 0.98 1.02 0.87 1.26 1.50
D2 0.32 0.32 0.39 0.47 0.55E2 1.30 1.65 1.65 2.05 2.26F2 3.9370/ 4.9213/ 4.9213/ 5.5118/ 6.2992/
3.9349 4.9188 4.9188 5.5093 6.2967
G2 6.77 6.81 7.48 8.50 9.09H2 1.00 1.28 1.28 1.28 1.59
J21) 1.97 2.36 2.36 2.76 3.23J22) 1.97 - - - -
K2 2.16 2.05 2.13 2.76 2.61L2 1.58 1.97 1.97 2.21 2.76
M2 0.20 0.20 0.20 0.28 0.24
N2 5.37 5.39 6.06 6.79 7.05P2 0.32 0.32 0.32 0.32 0.32Q2 1.10 1.10 1.30 1.42 1.61
R23) 1.38 1.38 1.61 1.77 1.97R24) 1.69 1.38 - 1.61 -
S2*3) M12 M12 M12 M16 M16x24 x24 x28 x36 x36
A3 4.80 5.28 5.67 6.10 6.69B3 2.60 2.60 2.60 2.95 3.29C3 0.937 0.937 0.937 1.094 1.250
D3* M12 M12 M12 M16 M16E3 1.1817/ 1.1817/ 1.3787/ 1.5755/ 1.7724/
1.1812 1.1812 1.3780 1.5749 1.7717F3 1.30 1.30 1.50 1.69 1.91
G3 5.37 5.39 6.06 6.79 7.05H3 0.93 1.20 1.20 1.20 1.52J3 0.95 0.95 1.10 1.42 1.42
K3 2.000 2.000 2.000 2.250 2.626L3 0.71 0.79 0.79 0.79 0.87S3 0.63 0.63 0.63 1.02 -T3 - - - - 2.68
* Metric thread1) Key shaft type K 3) Spline shaft type D2) " " " P 4) " " " Z.
Ports F12-30 F12-40 F12-60 F12-80 F12-110
A, B 3/4" 3/4" 3/4" 1" 11/4"size
Screw M10 M10 M10 M12 M14thread1) (0.79) (0.79) (0.79) (0.79) (1.02)
C, D M22 M22 M22 M22 M22thread2) x1.5 x1.5 x1.5 x1.5 x1.5
E - - - - M22thread2) x1.5
A, B: ISO 6162 1) Metric thread (depth in inches)2) Metric thread x pitch in mm.
Spline shaft (DIN 5480; in mm)
= Max 5100 psi (350 bar) operating pressure.
Metric key shaft (in mm)
Type K (standard) Type P (optional)
F12-30 30 dia. 25 dia.
-40 30 dia. -
-60 35 dia. -
-80 40 dia. -
-110 45 dia. -
Type D (standard) Type Z (optional)
F12-30 W30x2x14x9g W25x1.25x18x9g
-40 W32x2x14x9g W30x2x14x9g
-60 W35x2x16x9g W32x2x14x9g
-80 W40x2x18x9g W35x2x16x9g
-110 W45x2x21x9g -
26 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F12-30, -40, -60, -80 and -110(Cartridge versions)
Catalogue HY17-8249/US
Installation dimensions
A4
B4
A5
G5
R5Q5
Ø V5
Ø F5
See table
Type Cspline shaft
H5(±0.2)
K5
S5
T5
B5
C5
N5
Ø M6
Ø N6
Ø P6
L6
O-ring(included)
A6
B6
C6
K6
G6
H6
Q6
R6
P5
Port DPort BPort A
Port C1)
C4T6
E4
Ø D4(x2)
40 (-30, -40, -60, -110)43 (-80)
Flushingvalve
(optional)
Speedsensor
(optional)
Type C mounting flange
1) Inspection/ drain port
Port E (third drain port)
F12-110 barrel housing(ISO/cartridge version)
Shown: F12-80
Ø E5
J5
D5
L5
M5
Type K (X) key shaft
XX˚
27 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
Catalogue HY17-8249/US
Installation dimensions
O-ring dimensions (in mm)
F12-30 127x4
-40 150x4
-60 150x4
-80 180x4
-110 190x4
Ports F12-30 F12-40 F12-60 F12-80 F12-110
A, B 3/4" 3/4" 3/4" 1" 11/4"size
Screw M10 M10 M10 M12 M14thread3) (0.79) (0.79) (0.79) (0.87) (1.02)
C M14 M14 M14 M14 M14thread4) x1.5 x1.5 x1.5 x1.5 x1.5
D, E M18 M18 M22 M22 M22thread4) x1.5 x1.5 x1.5 x1.5 x1.5
A, B: ISO 6162 3) Metric thread (depth in inches)4) Metric thread x pitch in mm.
Dim. F12-30 F12-40 F12-60 F12-80 F12-110
A4 6.30 7.87 7.87 8.82 9.84B4 5.51 6.46 6.46 7.72 8.11C4 7.40 9.25 9.25 10.24 11.26D4 0.55 0.71 0.71 0.87 0.87E4 3.03 3.74 3.74 4.33 4.57
A5 3.94 4.33 4.92 5.31 5.71B5 2.32 2.56 2.76 3.05 3.35C5 0.98 1.02 0.87 1.26 1.50
D5 0.31 1) 2) 0.39 0.47 0.55E5 1.1817/ 1) 2) 1.3787/ 1.5755/ 1.7724/
1.1812 1.3780 1.5749 1.7717
F5 5.3150/ 6.2992/ 6.2992/ 7.4803/ 7.8740/5.3125 6.2967 6.2967 7.4775 7.8712
G5 5.00 5.24 5.75 6.18 6.89H5 3.50 3.63 3.63 4.35 4.83J5 1.97 2.36 2.36 2.76 -
K5 0.55 0.63 0.59 0.59 0.59L5 1.57 1.97 1.97 2.20 -
M5 0.20 0.20 0.20 0.28 -
N5 3.58 3.82 4.33 4.49 4.84P5 0.87 1.18 1.22 1.57 1.57Q5 1.10 1.10 1.10 1.46 1.46
R5 1.38 1.38 1.38 1.77 1.77S5 2.78 2.83 2.99 3.58 3.77T5 0.59 0.59 0.59 0.59 0.59V5 1.30 1.38 1.38 1.77 1.77
A6 4.80 5.28 5.67 6.10 6.69B6 2.60 2.60 2.60 2.95 3.27C6 0.937 0.937 0.937 1.094 1.250
G6 3.60 3.82 4.33 4.49 4.84H6 2.74 2.80 2.91 3.52 3.69K6 2.000 2.000 2.000 2.250 2.626
L6 0.63 0.71 0.71 0.79 0.79M6 3.62 4.53 4.53 5.12 5.51N6 4.33 5.00 5.31 6.06 6.30
P6 5.047 6.031 6.031 7.213 7.606Q6 0.20 0.20 0.20 0.20 0.20R6 0.20 0.20 0.20 0.20 0.20T6 - - - - 2.68
1) Key shaft type K: D5 - 0.31; E5 - 1.1817/1.18122) Key shaft type X: D5 - 0.39; E5 - 1.3787/1.3780
Spline shaft (DIN 5480; in mm)Type C (standard)
F12-30 W30x2x14x9g
-40 W30x2x14x9g
-60 W30x2x14x9g
-80 W40x2x18x9g
-110 W40x2x18x9g
Metric key shaft (in mm)Type K (std) Type X (opt.)
F12-30 30 dia. –
-40 - 35 dia.
-60 35 dia. –
-80 40 dia. –
-110 – –
28 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F12-30, -40, -60, -80 and -110(SAE versions with 4 bolt flange)
Catalogue HY17-8249/US
Installation dimensions
A7
A7 Ø D7 (x4)B7
Type S (SAE 4 bolt) mounting flange
C7T9
Port E (third drain port)
F12-110 barrel housing(SAE version)
A8
G8
J8
N8
L8Type Sflange
M8D8
Ø E8
Ø F8
H8
K8
Port C1)
B8
C8
Port D
Type Tkey shaft
Flushingvalve
(optional)
Speedsensor
(optional)
1) Inspection/ drain port
A9
B9
K9
L9
C9
G9
H9J9
F9
R8
Q8Seetable
D9 (thread)
Ø E9
Port A Port B
Type S (U)spline shaft
Shown: F12-80 with 4 bolt flange
29 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
Catalogue HY17-8249/US
Installation dimensions
Dim. F12-30 F12-40 F12-60 F12-80 F12-110
A7 3.54 4.51 4.51 4.51 6.36B7 4.65 5.83 5.83 6.10 8.03C7 4.65 5.67 5.67 6.10 7.87D7 0.55 0.55 0.55 0.55 0.83
A8 3.94 4.33 4.92 5.31 5.71B8 2.32 2.56 2.76 3.05 3.35C8 0.98 1.02 0.87 1.26 1.50
D8 0.25 0.31 0.31 0.38 0.44E8 1.30 1.65 1.65 2.05 2.26F8 4.000/ 5.000/ 5.000/ 5.000/ 6.000/
3.998 4.998 4.998 4.998 5.998
G8 7.46 7.76 8.43 9.45 10.39H8 0.31 0.31 0.31 0.31 0.31J8 1.50 1.89 1.89 2.13 2.64
K8 2.83 2.99 3.11 3.74 3.90L8 1.25 1.50 1.50 1.75 2.13
M8 0.10 0.16 0.16 0.16 0.29
N8 6.04 6.34 7.02 7.76 8.35Q81) 0.91 0.91 0.91 0.98 1.34Q82) - - - 0.91 -
R81) 1.30 1.89 1.89 2.13 2.63R82) - - - 1.88 -
A9 4.80 5.28 5.67 6.10 6.69B9 2.60 2.60 2.60 2.95 3.27C9 0.937 0.937 0.937 1.094 1.250
D9* 5/16"-24 3/8"-24 3/8"-24 1/2"-20 5/8"-18E9 1.000/ 1.250/ 1.250/ 1.500/ 1.750/
0.998 1.248 1.248 1.498 1.748F9 1.11 1.39 1.39 1.67 1.94
G9 6.06 6.34 7.02 7.76 8.35H9 0.38 0.50 0.50 0.50 0.50J9 0.63 0.75 0.75 1.02 1.26
K9 2.000 2.000 2.000 2.250 2.626L9 0.71 0.79 0.79 0.79 0.87T9 - - - - 2.68
* UNF-2B thread1) Spline shaft type S2) " " " U
Main ports A and B, type U (optional)
F12-110 1 5/8" - 12 UN
O-ring ports according to SAE J514d
Ports F12-30 F12-40 F12-60 F12-80 F12-110
A, B 3/4" 3/4" 3/4" 1" 11/4"size
Screw 3/8"-16 3/8"-16 3/8"-16 7/16"-14 1/2"-13thread3) (0.87) (0.79) (0.87) (1.06) (0.98)
C 7/8"-14 7/8"-14 7/8"-14 7/8"-14 11/16"-12thread
D 3/4"-16 3/4"-16 7/8"-14 7/8"-14 11/16"-12thread
E - - - - 11/16"-12thread
A, B: ISO 6162; C, D, E: O-ring boss (SAE J514)3) UN thread (depth in inches)
Key shaft (SAE J744)T (standard) X (optional)
F12-30 SAE 'B-B' -(1"/25.4 mm)
-40 SAE 'C' -(11/4"/31.75 mm)
-60 SAE 'C' -(11/4"/31.75 mm)
-80 SAE 'C-C' SAE ’D’(11/2"/ 38.1 mm) (13/4"/ 44.45 mm)
-110 SAE 'D' -(13/4"/ 44.45 mm)
Mounting flange (SAE J744)
S (standard) X (optional)
F12-30 SAE 'B', 4 bolt --40 SAE 'C', " --60 SAE 'C', " -
-80 SAE 'C', " SAE ’D’, 4 bolt-110 SAE 'D', " -
Spline shaft (SAE J498b, class 1, flat root, side fit)S (standard) U (opt.) X (optional)
F12-30 SAE 'B' - -13T, 16/32 DP
-40 SAE 'C' 14T, - -12/24 DP
-60 SAE 'C' 14T, - -12/24 DP
-80 SAE 'C-C' SAE 'C' SAE 'D'17T, 12/24 DP 14T,12/24DP 13T, 8/16 DP
-110 SAE 'D' - -13T, 8/16 DP
= Max 5100 psi (350 bar) operating pressure.
30 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F12-30, -40, and -60(SAE versions with 2 bolt flange)
Catalogue HY17-8249/US
Installation dimensions
Ø D10(x2)
A10
B10
G11
J11 D11
A11 B11
C11
N11
L12
A12
B12C12
G12
Port A Port B Port D
H12
K12
J12
F12
D12 (thread)
Type Tflange
Ø E12
L11
M11Ø E11
Ø F11
K11
H11
Port C(inspection/drain port)
Type Tkey shaft
R11
Q11 Seetable
Type S spline shaft
F10
E10 RC10 R
Flushing valve
(optional)
Speedsensor
(optional)
Shown: F12-60 with 2 bolt flange
31 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
Catalogue HY17-8249/US
Installation dimensions
Ports F12-30 F12-40 F12-60
A, B size 3/4" 3/4" 3/4"
Screw 3/8"-16 3/8"-16 3/8"-16thread1) (0.87) (0.79) (0.87)
C thread 3/4"-16 3/4"-16 7/8"-14
D thread 3/4"-16 3/4"-16 7/8"-14
A, B (main ports): SAE J518c (6000 psi)C, D (drain ports): O-ring boss (SAE J514)
1) UN thread (depth in inches).
Spline shaft(SAE J498b, class 1, flat root, side fit)
Type S
F12-30 SAE 'B'13 T; 16/32 DP
-40 SAE 'C'14 T; 12/24 DP
-60 SAE 'C'14 T; 12/24 DP
Mounting flange (SAE J744)
Type T
F12-30 SAE 'B', 2 bolt
-40 SAE 'C', 2 bolt
-60 SAE 'C', 2 bolt
Key shaft (SAE J744)
Type T
F12-30 1" dia. SAE 'B-B'
-40 11/4" dia. SAE 'C'
-60 11/4" dia. SAE 'C'
Dim. F12-30 F12-40 F12-60
A10 5.75 7.13 7.13B10 6.93 8.46 8.46C10 2.48 2.91 2.91
D10 0.57 0.69 0.69E10 0.39 0.63 0.63F10 0.39 0.61 0.61
A11 3.94 4.33 4.92B11 2.32 2.56 2.76C11 0.98 1.02 0.87
D11 0.25 0.31 0.31E11 1.30 1.65 1.65F11 4.000/ 5.000/ 5.000/
3.998 4.998 4.998
G11 7.46 7.76 8.43H11 0.31 0.31 0.31J11 1.50 1.89 1.89
K11 2.80 3.03 3.21L11 1.25 1.50 1.50
M11 0.10 0.16 0.16
N11 6.06 6.34 7.03Q11 1.02 1.06 1.06R11 1.30 1.89 1.89
A12 4.80 5.28 5.67B12 2.60 2.60 2.60C12 0.937 0.937 0.937
D12* 5/16"-24 3/8"-24 3/8"-24E12 1.000/ 1.250/ 1.250/
0.998 1.248 1.248F12 1.11 1.39 1.39
G12 6.06 6.34 7.03H12 0.38 0.50 0.50J12 0.63 0.75 0.75
K12 2.000 2.000 2.000L12 0.71 0.79 0.79
* UNF-2B thread
Main ports A and B, type U (optional)
F12-30 1 1/16" - 12 UN-40 1 5/16" - 12 UN-60 1 5/16" - 12 UN
O-ring ports according to SAE J514d
= Max 350 bar operating pressure.
32 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F11-150(CETOP version)
Catalogue HY17-8249/US
Installation dimensions
4.29
10
0.986.26
12.09
6.77 4.65
0.71
Drain port DBSP 3/4"
Ø2.24min
Ø7.87407.8712
Ø9.84 Ø0.87(x4)
9.29 max
9.29
Approx. center ofgravity
R 0.04
14x9x70(0.55x0.35x2.76;metric key)
R 0.03Flange C
Type C mounting flange
8.74 max
3.98
3.35
2.11
3.125
1.18
9.84
1.97
3.23
1.81
ØM16(x8)*1.44
Main port A1 1/2" **
Main port B1 1/2" **
Drain port CBSP 3/4"
Ø1.9692/1.9686
M16 (metric thread)
Type K key shaft
1.97
1.97W45x2x21x9g(metric spline)
Spline shaft D (DIN 5480)
* Metric thread, deep1.4** 6000 psi flange (SAE J581c)
1.18M16 (metric thread)
33 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F11-150(SAE version)
Catalogue HY17-8249/US
Installation dimensions
8.74 max
3.98
3.35
1.94
3.13
1.18
11.69
6.18 0.94
8.11
13.98
0.31
2.63
0.50
ØM16* (x8)
1.437
6.77 4.65
0.71Main port A
1 1/2" **Main port B1 1/2" **
Drain port CBSP 3/4"
Drain port DBSP 3/4"
Ø1.750/1.748
Ø2.24min
Ø6.000/5.998
7/16"x7/16"x21/8"(key)
Key shaft T SAE 'D'
(SAE J744c)
Ø0.83 (x4)
8.43 max
7.566.362
Approx. center ofgravity
R 0.04R 0.03
0.31
2.63SAE 'D'; 13T, 8/16 DP;class 1, flat root, side fit
Spline shaft S (SAE J498b)
Mounting flange SSAE 'D' (SAE J744c)
Flange S
* Metric thread, deep1.4** 6000 psi flange (SAE J581c)
34 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F11-250(SAE version)
Catalogue HY17-8249/US
Installation dimensions
9.13
3.98
5.55
3.125
M16 (metricthread)
13.23
6.368.11max
0.50
1.22
R 0.03
M16 (x8)1.4 deep(metric thread)1.437
7.76 4.65
0.94
1.06Main port A
1 1/2" *Main port B
1 1/2" *
Drain port CBSP 3/4"
Drain port DBSP 3/4"
2.11
Ø6.000/5.998
6.36
8.11 max
Ø0.83(x4)
Ø1.9692/1.9686
Type K key shaft(metric; not SAE)
14x9x70(0.55x0.35x2.76;metric key)
Ø2.24min
Ø1.54(x2)
7.09
15.55
3.23
0.31
8.50
Approx. center of
gravity
R 0.03
0.31
2.63
1.38
Mounting flange SSAE 'D' (SAE J744c)
Spline shaft F (SAE J498b)
SAE F; 15T, 8/16 DP;class 1, flat root, side fitOptional: SAE S; 13T, 8/16 DP
* 6000 psi flange (SAE J581c)
35 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
F11 with built-inmake-up valve
Saw bar supporteddirectly on themotor flange
Feedcylinder
Chain spur gear mounteddirectly on the shaft
Sawchain
Protectivecover
Sawbar
Port A Port B
Port GOnly for F11-10, -19(for make-up flowif required)
Port C/D
Chain saw installation (example; F11-10 shown)
F11 fan motors
Frame sizes -10, -14 and -19 are also available as 'fanmotors' with a built-in check valve (refer to the sche-matic below) and CETOP mounting flange. Just like thesaw motor, the fan motor can be operated at very highspeeds without reliability problems.The fan is usuallyinstalled directly on the motor shaft without additionalbearing support.Additional information (available versions, orderingcodes, installation dimensions, etc.) is available inpublication 'F11 Fan Motors'(catalogue 9129 8247-02).
Fan motor (F11-10 shown).
Fan motor schematic (left hand rotation shown).
F11 saw motors
Series F11 motors have proven extremely reliable indemanding applications such as bar (chain) saws.Primarily due to the 40° bent-axis design, sphericalpistons (with laminated piston rings) and gear synchro-nization, very high speeds are permissible. Not evenlow temperatures at start-up affect reliability.To further enhance the saw function and, at the sametime, reduce weight, cost and installation dimensions, aspecific saw motor has been developed (frame sizes-10, -14 and -19; refer to the illustration to the right)which is specifically dedicated to bar saws. The motorallows the saw bar bearings to be mounted directly onthe motor housing, and the spur gear installs on themotor shaft without any additional bearings.For more detailed information (available versions,ordering codes, installation dimensions, etc.), refer to'F11 Saw Motors' (catalogue 9129 8245-02).
Catalogue HY17-8249/US
Technical information
ABuilt-inmake-up
valve
Mountingflange C(CETOP)
Key shaft K(CETOP)
Port GMain port B
Main port A Drain port C
Alternativedrain port D
36 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
Integrated flushing valve(F12-30, -40, -60, -80)
Nozzle(optional)
Port A
Port B
Built-influshingvalve
Nozzle(optional)
FV13 flushingvalve block
Nozzle(optional)
Port A
Port B
Nozzle (optional)
FV13 flushingvalve block
F12 accessory valve blocks
Type FV13 flushing valve (for F12-110)
A separate flushing valve block is available for theF12-110. It has the same function as the integratedvalve for the other F12 frame sizes (above).The valve block mounts between the motor port flangeand the split flanges as shown to the right.An optional nozzle can be installed in the valve blockdrain port.Ordering code: FV13
NOTE: Additional information is available inpublication ’Mobile motor/pump accessories’(catalogue HY17-8258/UK).
F12 integrated flushing valve(F12-30, -40, -60 and -80)Series F12 (except F12-110; refer to the FV13 flushingvalve block below) is available with an integratedflushing valve which provides the rotating parts with anadditional cooling flow, required when operating at highspeeds and power levels.In a hydrostatic transmission, the valve also ensuresthat part of the main circuit fluid is being removed andreplaced by cool, filtered fluid from the charge pump.The flow is limited by a suitably sized nozzle thatinstalles below a plug in the motor port flange.
NOTE: Ordering code, available nozzles andother information is provided in publica-tion ’Mobile motor/pump accessories’(catalogue HY17-8258/UK).
Catalogue HY17-8249/US
Technical information
37 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
BT brakevalve block
BT brakevalve block
F12-motor
Brake release valveflushing valve etc.
Port BR(brakerelease)
Port A
Port B
Port S(make-up)
Port G
SR valve block
Type SR pressure relief/make-up valveThe SR pressure relief/make-up valve block for seriesF12 motors is designed to protect the motor from highpressure spikes as well as provide an excellent make-up function to help prevent motor cavitation (when portG is pressurized).The valve block mounts between the motor port flangeand the split flanges (as shown to the right).
The SR block is available in three sizes:- SR11 (3/4") for F12-30, -40, -60
- SR12 (1") for F12-80
- SR13 (11/4") for F12-110
NOTE: - For additional information such aspressure settings and installationdimensions, refer to publication’Mobile motor/pump accessories’(catalogue HY17-8258/UK).
- To obtain a combined cross-over relief/make-up and flushing function on theF12-110, the SR13 and FV13 valveblocks can be stacked (with the flushingvalve block mounted next to the motor).
Type BT brake valveWhen a motor (in an open loop system) is used in ahydrostatic vehicle transmission, the motor mayoperate faster than what corresponds to the availablepump flow (e.g. in a steep downhill); this can lead tomotor cavitation and loss of braking power.The BT brake valve prevents cavitation by throttlingthe return flow from the motor as soon as the pressurelevel in the inlet port decreases to approximately 35bar. At the same time, motor braking is provided whenthe pump flow decreases or is shut off.The BT brake valve can be supplied with variousoptional functions such as a mechanical brake releasevalve and a flushing valve.The valve block is very compact and installs betweenthe motor port flange and the split flanges(refer to the illustration).
The BT valve block is available in two sizes:
- BT21 (3/4") for F12-30, -40, -60
- BT22 (1") for F12-80
NOTE: Detailed information on the BT valve isprovided in publication’Mobile motor/pump accessories’(catalogue HY17-8258/UK).
Catalogue HY17-8249/US
Technical information
Port A
Port B
Port G SR valve block F12-motorPort L
38 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
SV pressure reliefvalve block
SV valve block
Port A
Port B
(Port L)
Speedsensor
Type SV pressure relief valveThe SV pressure relief valve for series F12 motorsprotects the motor and the corresponding main hy-draulic lines from pressure spikes. Like the SR valveblock (page 31), it has integrated cartridge typepressure relief valves and mounts between the motorport flange and the split flanges as shown to the right.The design of the relief valves permits a limited make-up flow (when port L is pressurized).The SV valve block is available in three sizes:- SV11 (3/4") for F12-30, -40, -60
- SV12 (1") for F12-80
- SV13 (11/4") for F12-110
NOTE: - Detailed information on availablepressure settings, installation dimen-sions, etc. is provided in publication’Mobile motor/pump accessories’(catalogue HY17-8258/UK).
- On the F12-110, the FV13 flushing valveblock (page 36) can be mounted betweenthe SV13 block and the motor port flangeto obtain a combined pressure relief andflushing function.
Speed sensor
A speed sensor kit is available for series F11/F12.A ferrostat differential (Hall-effect) sensor installs in aseparate, threaded hole in the F11/F12 bearinghousing.On F12 the speed sensor is directed towards the ringgear.On F11 the speed sensor is directed towards thepistons. The speed sensor outputs a square wavesignal within a fequency range of 5 Hz to 20 kHz.NOTE: - The motor bearing housing must be
prepared for the speed pick-up;refer to the F11/F12 ordering codes(pages 7-12).
- On F11 the pistons position must be known before mounting.
- Additional information is provided in’Mobile motor/pump accessories’(catalogue HY17-8258/UK).
- The speed sensor is also shown in theillustrations on pages 19, 21, 22, 24, 26and 28.
Catalogue HY17-8249/US
Technical information
F12 with speed sensor.
F11-14 with speed sensor.
Speedsensor
39 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
L
2"hose
Suctionfitting
(Split-flangehalf)
(Mountingscrew)
(O-ring)
Suction fittingsTo minimize the risk for cavitation when operating theF12 as a pump, we recommend using our suctionfittings; all take 2" hoses.
Part no. SAE size For L [inch]
379 4070 3/4" F12-30 3.94F12-40F12-60
370 4095 1" F12-80 3.94
370 3916 11/4" F12-110 4.02
The suction fittings are designed for use with standardSAE or metric split-flange halves as shown.O-ring and mounting screw sizes are listed below.
SAE O-ring Screw sizesize dimension [mm] SAE Metric3/4" 30.0x3.53 3/8"-16x1.50 M10x35
1" 32.9x3.53 7/16"-14x1.50 M12x4011/4" 37.7x3.53 1/2"-13x1.75 M14x45
Suction fitting kitsSuction fitting kits are available for the F12 ISO andCartridge versions. A kit consists of a suction fitting(shown above), two split-flange halves, anO-ring and four mounting screws.
Part no. SAE size For Screw size
379 4421 3/4" F12-30/-40/-60 M10x35370 4098 1" F12-80 M12x40370 3926 11/4" F12-110 M14x45
Split-flange kitsSeparate metric split-flange kits, consisting of two split-flange halves and four mounting screws for use on theF12 ISO and cartridge versions, are also available.
Part no. SAE size For Screw size
379 4405 3/4" F12-30/-40/-60 M10x35370 4329 1" F12-80 M12x40
370 4330 11/4" F12-110 M14x45
F12 main port suction fittings
(Split-flangehalf)
(Mountingscrew)
Catalogue HY17-8249/US
Technical information
40 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
Clockwise rotation
Port A Port B
Counterclockwiserotation
Direction of rotationThe M and H versions of series F11, and the M versionof series F12, are bi-directional.The L and R pump versions are uni-directional, allow-ing higher selfpriming speeds(refer to page 14).The illustration to the right shows direction of flowversus shaft rotation. In a motor application, the shaftturns clockwise when port B (black arrow) is pressu-rized, and counter clockwise when port A (open arrow)is pressurized.In a pump application where the shaft turns clock-wise,port B is the inlet port and should be connected to tank;when the shaft turns counter clockwise, port A is theinlet port.
Hydraulic fluidsRatings and performance data for series F11/F12 arebased on operating with good quality, contamination-free, petroleum-based fluids.Hydraulic fluids type HLP (DIN 51524), automatictransmission fluids type A, or API CD engine oils canbe used.Fire resistant fluids (when used under modified operat-ing conditions) and synthetic fluids may also be suit-able.For additional information, refer to Hydraulic MarketingIS data base:- Hydraulic fluid specifications- Fire resistant fluids.
Operating temperatureThe following temperatures should not be exceeded(type H and N shaft seals):Drain fluid: 195 °F (90 °C)Viton shaft seals (F11 type E, F12 type V) can be usedto 240 °F (115 °C) drain fluid temperature.NOTE: The temperature should be measured at
the utilized drain port.Continuous operation may require case flushing inorder to meet the viscosity and temperature limitations.The following table shows operating speeds, abovewhich flushing is usually required, as well as suggestedflow through the case.
NOTE:
When operating the F11/F12 as a pump above theselfpriming speed (valid for both the pump andmotor versions), the inlet must be sufficientlypressurized. Increased noise and deterioratingperformance may otherwise be experienced.For further information refer to ’Selfpriming speedand required inlet pressure’ on page 6.
Catalogue HY17-8249/US
Installation information
Series F12Frame size Speed [rpm] Flow [l/min] Flow [gpm]
F12-30 3500 4–8 1.0–2.1F12-40 3000 5–10 1.3–2.6F12-60 3000 7–14 1.9–3.7F12-80 2500 8–16 2.1–4.2
F12-110 2300 9–18 2.4–4.8
Series F11Frame size Speed [rpm] Flow [l/min] Flow [gpm]
F11-5 5500 1–2 0.25-0.5F11-10 4500 2–3 0.5-0.8F11-14 4500 2–3 0.5-0.8F11-19 4000 2–4 0.5-1.0
F11-150 2200 10–20 2.6-5.2F11-250 1800 12–22 3.2-5.8
41 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
Catalogue HY17-8249/US
Installation information
Shaft seal H/V N H/V N H/V N H/V N H/V N
F12-30 205 30 100 20 80 15 65 10 50 -F12-40 175 30 85 15 65 10 50 5 - -F12-60 175 30 85 15 65 10 50 5 - -
F12-80 145 30 70 10 60 5 - - - -F12-110 140 30 65 10 - - - - - -
Max recommended case pressure versus shaft speed -F12 seal types H or V, and N
Series F12
Shaft seal H/V N/E H/V N/E H/V N/E H/V N/E H/V N/E H/V N/E H/V N/E H/V N/E H/V N/E H/V N/E
F11-5 20 2.2 13 1.9 10 1.6 8 1.3 6.5 0.9 5 0.6 4.2 0.5 4 0.3 3.5 0.2 3 0F11-10 20 2.2 11.5 1.8 8.5 1.2 7 1.0 5.5 0.7 4 0.5 3.8 0.4 3.5 0.2 3.0 0 - -F11-14 19 2.2 9.5 1.5 7 1.0 5.5 0.8 4.5 0.5 3.5 0.4 3.0 0.2 2.5 0 - - - -F11-19 19 2.2 9.5 1.4 7 0.9 5.5 0.6 4.5 0.4 3.5 0.3 3.0 0 - - - - - -
F11-150 9.5 2.2 4.5 0.6 - - - - - - - - - - - - - - - -F11-250 9.5 - 4.5 - - - - - - - - - - - - - - - - -
Max case pressure [psi] versus shaft speed [rpm]Speed 1500 3000 4000 5000 6000 8000 9000 10000 11000 12000
Max recommended case pressure versus shaft speed - F11 seal types H or V and N or E.
Max case pressure [psi] vs. shaft speed [rpm]Speed 1500 3000 4000 5000 6000
Series F11
ViscosityThe ideal operating range is75 to 150 SUS(15 to 30 mm2/s).At operating temperature, the viscosity (of the drainfluid) should be kept above 46 SUS (8 mm2/s [cSt]).At start-up, the viscosity should not exceed5 000 SUS (1000 mm2/s)
FiltrationTo obtain the highest service life of the F11/F12,the fluid cleanliness should meet or exceedISO code 18/13 (ISO 4406).During normal operating conditions, a 10 µm(absolute) filter is recommended.
Case pressureThe tables below show the highest recommendedcase pressure as a function of shaft speed.‘Nominal’ shaft seal life can be expected at a certainspeed and the corresponding max case pressure. Seallife will be shorter, however, at unfavourable operatingconditions (high temperature, low oil viscosity,contaminated oil).
42 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
Port CPort E(F12-110)
Port D
Drain flow
Flushing flow(when required)
Spring loadedcheck valve
Drain flow
Case drain connectionsSeries F11/F12 have two drain ports, C and D, whileF12-110 has an additional port, E.The uppermost drain port (such as port C in the illus-tration below) should always be utilized.
In mounting positions such as 'shaft up' (below)a spring loaded check valve should be installed in thedrain line in order to insure a sufficiently high oil levelin the case.Preferably, the drain line should be connected directlyto the reservoir.
Before start-upMake sure the F11/F12 case as well as the entirehydraulic system is filled with a recommended fluid.The internal leakage, especially at low operatingpressures, is not sufficient to provide lubrication atstart-up.
NOTE:- To avoid cavitation and obtain a low noise level as
well as reduced heat generation, tubes, hoses andfittings must be adequately dimensioned.
- Preferably, the suction line flow speed should be1.5 to 3.5 fps (0.5 to 1 m/s), and pressure line flowspeeds 10 to 16 fps (3 to 5 m/s).
- For series F12, suitable suction fittings are available(refer to page 39).
Catalogue HY17-8249/US
Installation information
43 Parker HannifinMobile Controls DivisionTrollhättan, Sweden
Hydraulic motor/pumpSeries F11/F12
Offer of SalePlease contact your Parker representation for a detailed ”Offer of Sale”.
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBEDHEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provideproduct and/or system options for further investigation by users having technical expertise. It is important that you analyze allaspects of your application, including consequences of any failure, and review the information concerning the product orsystem in the current product catalogue. Due to the variety of operating conditions and applications for these products orsystems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products andsystems and assuring that all performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing, aresubject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.
WARNING!
Catalogue HY17-8249/US
General information
Parker Hannifin is the world’s premier supplier of motion and control systemsand solutions, with sales and manufacturing facilities throughout the world.For product information and details of your nearest Parker sales office, visit usat www.parker.com or call free on 1-800-272-7537 (North America).
Hydraulics GroupSales Offices
Catalogue HY17-8249/US2M 03/04 RT
© Copyright 2004Parker Hannifin CorporationAll rights reserved.
North America
USA, Canada100 Parker DriveOtsego, MI 49078USATel: +1 269-694-9411Fax: +1 269-694-4638
MexicoVia de Ferrocarril a Matamoros #730Apodaca, N.L.MexicoC.P. 6 6 6 0 0Tel: +52 81 56 6000Fax: +52 81 56 6076
Latin America
Pan American Division7400 N.W. 19th StreetSuite AMiami, FL 33126USATel: +305 470 8800Fax: +305 470 8808
ArgentinaStephenson 2711(1667) Tortuguitas–Malvinas ArgentinasPcia. de Buenos AiresArgentinaTel: +54 11 4752 4129Fax: +54 11 4752 3704
BrazilAv. Lucas Nogueira Garcez2181 Jacarei, SP Brazil 12300-000BrazilTel: +55 12 354 5100Fax: +55 12 354 5262
ChileAv. Americo Vespucio 2760-C,ConchaliSantiagoChileTel: +56 2 623 1216Fax: +56 2 623 1421
VenezuelaAv. Principal de Boleita Norte con Calle Miraima,Edf. Draza, Planta BajaCaracas 1070VenezuelaTel: +58 212 238-5422Fax: +58 212 239-2272