Lecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry & Chromatography Prof. Jose-Luis Jimenez Fall 2002 Part I: General Detector Properties

Upload: others

Post on 29-Mar-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Lecture 17:Chromatographic Detectors

CU- Boulder CHEM 5181

Mass Spectrometry & Chromatography

Prof. Jose-Luis JimenezFall 2002

Part I:General Detector

Properties

Page 2: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Important Detector Properties

• Signal-to-Noise Ratio– Sensitivity– Baseline noise

• Selectivity• Others

– Baseline drift– Response time– Dynamic range– Linear range

Detection Sensitivity

From Snyder

Page 3: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Detection Noise

From Snyder

Example of Signal-to-Noise Ratio (SNR)

From McNair

Page 4: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Relative Precision vs. Concentration

From Snyder

Detector Noise vs. Detector Drift

From McNair

Page 5: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Detection Selectivity

From Snyder

Definition of Detector Response Time

From McNair

Page 6: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Effect of Detector Time Constant

From McNair

Detector Dynamic Range

From McNair

Page 7: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Detector Linearity

From McNair

Part II:GC Detectors

Page 8: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Most Common Detectors

• Flame Ionization Detector (FID)– C atom counter

• Thermal Conductivity Detector (TCD)• Electron-Capture Detector (ECD)• MS• Up to 60 other types of detectors used

Flame Ionization Detector

From Rubinson

Page 9: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

FID Response

From McNair

FID Implementations I

From Skoog

Page 10: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

FID Implementations II

From McNair

Effect of H2 Flow Rate on FID Response

From McNair

Page 11: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Effect of Air Flow Rate on FID Response

From McNair

Need for Other Detectors than FID

From McNair

Page 12: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Thermal Conductivity Detector

From Rubinson2

Thermal Conductivity Detector (TCD)

From Schwedt

Page 13: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Thermal Conductivities of Carriers & Analytes

From McNair

Electron-Capture Detector (ECD)

From McNair

Page 14: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

ECD Detector

From Rubinson2

Relative ECD Responses

From McNair

Page 15: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Properties of GC Detectors

From McNair

Concentration vs. Mass Flow Rate Detectors

From McNair

Page 16: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Nitrogen-Phosphorus Detector

From Rubinson2

Photoionization Detector

From Rubinson2

Page 17: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Infrared Detection

From Skoog

Atomic Emission Detector

From Skoog

Page 18: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Concentration Ranges for GC Detectors

From McNair

GC Detectors Comparison I

From McNair

Page 19: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

GC Detectors Comparison II

From Rubinson

GC Detectors Comparison III

From Settle

Page 20: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

GC Detectors Comparison IV

From Grant

Part III:HPLC Detectors

Page 21: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

HPLC Detectors

• Most common: UV absorption• Alternative detectors when:

– Analytes don’t have UV absorption– Analyte concentrations are too low for UV abs.– Sample interferences are important– Structural information is required

UV Detectors

From Skoog & Snyder

Page 22: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Choosing a UV Wavelength

UV Diode Array Detection

From Snyder

Page 23: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

UV Diode Array Detection

Micro-Capillary Absorption Detection

From Rubinson

Page 24: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Dual-Beam HPLC Detector

From Rubinson

UV Absorptivity of Common Organic Functional Groups

From Snyder

Page 25: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

UV Absorption Spectra at Low UV Wavelengths

From Snyder

How to Increase SNR in UV Detection

From Snyder

Page 26: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Universal HPLC Detectors

• Used when – you want a response for all solutes on the

mobile phase• UV can have 100 to 1000 fold differences in

sensitivity between molecules– Analytes do not absorb UV

Refractive Index Detector

Page 27: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Evaporative Light Scattering Detector

From Snyder

Universal HPLC Detectors

From Snyder

Page 28: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Fluorescence Detector

From Snyder

Arrangement of LC Fluorescent Detector

From Rubinson

Page 29: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Other HPLC

Detectors

From Snyder

Light Scattering Detector

From Rubinson

Page 30: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Amperometric Detector

Viscometric Detector

From Rubinson

Page 31: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

Post-Column Chemical Reaction Detection

From Schwedt

HPLC Detectors Comparison I

From Skoog

Page 32: Part I: General Detector Properties - welcome | CIREScires.colorado.edu/jimenez/CHEM-5181/Lect/C7_Detectors.pdfLecture 17: Chromatographic Detectors CU- Boulder CHEM 5181 Mass Spectrometry

HPLC Detectors Comparison II

From Rubinson

HPLC Detectors Comparison III

From Cunico