4
P E I S L E Y S T R E E T NO. 143 PEISLEY STREET NO. 131 - 133 PEISLEY STREET NO. 137 NO. 30 - 32 MCNAMARA STREET (QUEST APARTMENTS) LANEWAY 1 DA0003 EXISTING ROLLERSHUTTER EXISTING SEWER MANHOLE LINE OF EXISTING SEWER EXISTING SEWER BOUNDARY TRAP UPGRADE EXISTING DOOR TO OPEN OUTWARDS AND MAKE COMPLIANT WITH AS 1428.1 NEW TRENCHED SEWER CONNECTION 2600 5500 5500 5500 EXISTING MALE WC EXISTING COVERED WELL UAT 01 02 03 1000 NEW FIRE EGRESS DOOR EXTENT OF FIRE RATED CLADDING TO EXISTING WALL EXTENT OF FIRE RATED CLADDING TO EXISTING WALL EXISTING SIGNAGE PRIVATE OUTDOOR AREA FR FR NEW PREFABRICATED ACCESSIBLE TOILET SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY NEW RAINWATER TANK EXISTING BLUESTONE KERB NO. 24 MCNAMARA STREET NO. 141 PEISLEY STREET EXISTING FEMALE WC EXISTING WAREHOUSE REFER DA0002 FOR PROPOSED INTERNAL LAYOUT 2600 2600 1 DA0001 3 DA0003 Sim ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE STATED. REDUCED LEVELS (RL) ARE TO AUSTRALIAN HEIGHT DATUM (AHD). COORDINATES ARE TO MAP GRID AUSTRALIA (MGA). DESIGN DRAWINGS ARE BASED ON 3RD PARTY SURVEY INFORMATION. PRIOR TO CONSTRUCTION ALL SET-OUT DIMENSIONS, SITE AND PROPERTY BOUNDARIES, EXISTING LEVELS, STRUCTURE, SERVICES, BUILDING FABRIC AND SITE FEATURES ARE TO BE VERIFIED ON SITE BY A REGISTERED SURVEYOR - INFORMATION PERTAINING TO EXISTING BUILDING FABRIC AND SITE FEATURES, INDICATED WITHIN THE DOCUMENTATION IS NOT GUARANTEED AS COMPLETE OR CORRECT. NOTIFY THE SUPERINTENDENT IN WRITING OF THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT CONTRACTS, ARCHITECTURAL DRAWINGS, SCHEDULES, REPORTS AND SPECIFICATIONS, AND ALL STRUCTURAL, CIVIL, MECHANICAL, ELECTRICAL, FIRE ENGINEERING, FIRE SERVICES, HYDRAULIC, ACOUSTIC, LANDSCAPE AND OTHER RELEVANT CONSULTANT DRAWINGS, SPECIFICATIONS AND REPORTS. DO NOT PROCEED TO CONTRACTOR DESIGN, FABRICATION AND/ OR CONSTRUCTION WITHOUT WRITTEN CONFIRMATION THAT ALL CONSULTANT DOCUMENTATION IS ISSUED. REPORT ANY DISCREPANCIES BETWEEN THE ARCHITECTURAL DOCUMENTATION AND OTHER CONSULTANT AND/OR PROJECT DOCUMENTATION TO THE SUPERINTENDENT FOR CLARIFICATION, PRIOR TO THE COMMENCEMENT OF THE AFFECTED WORKS. THE ARCHITECTURAL DOCUMENTATION IS ONLY ALLOWED GENERAL NOTES: 0 issue amendment date scale drawn checked drawing no. drawing project issue project no client 1 2 3 4 5 m 1 : 100@A1 28/04/2020 2:51:36 PM A 190018 MAD HATTER WINE CO, 137 PEISLEY STREET, ORANGE NSW LD RM DA0000 SITE PLAN A UPDATED DA APPLICATION 28.04.20

Upload: others

Post on 21-Jul-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Peisley Street DA - Orange City Council · new fire egress door extent of fire rated cladding to existing wall extent of fire rated cladding to existing wall existing signage private

P E

I S

L E

Y

S

T R

E E

T

NO. 143PEISLEY STREET

NO. 131 - 133PEISLEY STREET

NO. 137

NO. 30 - 32 MCNAMARA STREET(QUEST APARTMENTS)

LANEWAY

1DA0003

EXISTING ROLLERSHUTTER

EXISTING SEWER MANHOLE

LINE OF EXISTING SEWER

EXISTING SEWER BOUNDARY TRAP

UPGRADE EXISTING DOOR TO OPEN OUTWARDS AND MAKE COMPLIANT WITH AS 1428.1

NEW TRENCHED SEWER CONNECTION

2600

5500 5500 5500

EXISTING MALE WC

EXISTING COVERED WELL

UAT

01 02 03

1000

NEW FIRE EGRESS DOOR

EXTENT OF FIRE RATED CLADDING TO EXISTING WALL

EXTENT OF FIRE RATED CLADDING TO EXISTING WALL

EXISTING SIGNAGE

PRIVATE OUTDOOR

AREA

FR

FR

NEW PREFABRICATED ACCESSIBLE TOILET

SITE BOUNDARY

SITE BOUNDARY

SIT

E B

OU

ND

AR

Y

SIT

E B

OU

ND

AR

Y

SITE BOUNDARY

SIT

E B

OU

ND

AR

Y

SITE BOUNDARY

NEW RAINWATER TANK

EXISTING BLUESTONE KERB

NO. 24MCNAMARA STREET

NO. 141PEISLEY STREET

EXISTING FEMALE WC

EXISTING WAREHOUSEREFER DA0002 FOR PROPOSED INTERNAL LAYOUT

2600 2600

1DA0001

3DA0003

Sim

• ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE STATED.

• REDUCED LEVELS (RL) ARE TO AUSTRALIAN HEIGHT DATUM (AHD). COORDINATES ARE TO MAP GRID AUSTRALIA (MGA).

• DESIGN DRAWINGS ARE BASED ON 3RD PARTY SURVEY INFORMATION. PRIOR TO CONSTRUCTION ALL SET-OUT DIMENSIONS, SITE AND PROPERTY BOUNDARIES, EXISTING LEVELS, STRUCTURE, SERVICES, BUILDING FABRIC AND SITE FEATURES ARE TO BE VERIFIED ON SITE BY A REGISTERED SURVEYOR - INFORMATION PERTAINING TO EXISTING BUILDING FABRIC AND SITE FEATURES, INDICATED WITHIN THE DOCUMENTATION IS NOT GUARANTEED AS COMPLETE OR CORRECT. NOTIFY THE SUPERINTENDENT IN WRITING OF

• THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT CONTRACTS, ARCHITECTURAL DRAWINGS, SCHEDULES, REPORTS AND SPECIFICATIONS, AND ALL STRUCTURAL, CIVIL, MECHANICAL, ELECTRICAL, FIRE ENGINEERING, FIRE SERVICES, HYDRAULIC, ACOUSTIC, LANDSCAPE AND OTHER RELEVANT CONSULTANT DRAWINGS, SPECIFICATIONS AND REPORTS. DO NOT PROCEED TO CONTRACTOR DESIGN, FABRICATION AND/ OR CONSTRUCTION WITHOUT WRITTEN CONFIRMATION THAT ALL CONSULTANT DOCUMENTATION IS ISSUED.

• REPORT ANY DISCREPANCIES BETWEEN THE ARCHITECTURAL DOCUMENTATION AND OTHER CONSULTANT AND/OR PROJECT DOCUMENTATION TO THE SUPERINTENDENT FOR CLARIFICATION, PRIOR TO THE COMMENCEMENT OF THE AFFECTED WORKS.

• THE ARCHITECTURAL DOCUMENTATION IS ONLY ALLOWED

GENERAL NOTES:

0

issue amendment date

scale

drawn

checked drawing no.

drawing

project

issue

project no

client

1 2 3 4 5

m

1 : 100@A1

28/04/2020 2:51:36 PM

A190018

MAD HATTER WINE CO, 137PEISLEY STREET, ORANGE NSW

LD

RM

DA0000

SITE PLAN

A UPDATED DA APPLICATION 28.04.20

Page 2: Peisley Street DA - Orange City Council · new fire egress door extent of fire rated cladding to existing wall extent of fire rated cladding to existing wall existing signage private

EXISTING POLYCARBONATE SHEETING RETAINED

EXISTING FACE BLOCKWORK RETAINED

EXISTING ROLLERSHUTTER RETAINED

EXISTING VISION GLAZING RETAINED

EXISTING POLYCARBONATE SHEETING REMOVED TO ALLOW FOR FIRE RATED CLADDING

EXISTING POLYCARBONATE SHEETING REMOVED TO ALLOW FOR FIRE RATED CLADDING

COL.

EXISTING WAREHOUSE173m2

EX

IST

ING

RO

LLE

RS

HU

TT

ER

COL.

COL.

COL.

FORM NEW OPENING IN BLOCKWORK WALL TO ALLOW FOR NEW FIRE EGRESS DOOR

EXISTING FIRE EGRESS DOOR

EXISTING ELECTRICAL SWITCHBOARD

• ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE STATED.

• REDUCED LEVELS (RL) ARE TO AUSTRALIAN HEIGHT DATUM (AHD). COORDINATES ARE TO MAP GRID AUSTRALIA (MGA).

• DESIGN DRAWINGS ARE BASED ON 3RD PARTY SURVEY INFORMATION. PRIOR TO CONSTRUCTION ALL SET-OUT DIMENSIONS, SITE AND PROPERTY BOUNDARIES, EXISTING LEVELS, STRUCTURE, SERVICES, BUILDING FABRIC AND SITE FEATURES ARE TO BE VERIFIED ON SITE BY A REGISTERED SURVEYOR - INFORMATION PERTAINING TO EXISTING BUILDING FABRIC AND SITE FEATURES, INDICATED WITHIN THE DOCUMENTATION IS NOT GUARANTEED AS COMPLETE OR CORRECT. NOTIFY THE SUPERINTENDENT IN WRITING OF

• THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT CONTRACTS, ARCHITECTURAL DRAWINGS, SCHEDULES, REPORTS AND SPECIFICATIONS, AND ALL STRUCTURAL, CIVIL, MECHANICAL, ELECTRICAL, FIRE ENGINEERING, FIRE SERVICES, HYDRAULIC, ACOUSTIC, LANDSCAPE AND OTHER RELEVANT CONSULTANT DRAWINGS, SPECIFICATIONS AND REPORTS. DO NOT PROCEED TO CONTRACTOR DESIGN, FABRICATION AND/ OR CONSTRUCTION WITHOUT WRITTEN CONFIRMATION THAT ALL CONSULTANT DOCUMENTATION IS ISSUED.

• REPORT ANY DISCREPANCIES BETWEEN THE ARCHITECTURAL DOCUMENTATION AND OTHER CONSULTANT AND/OR PROJECT DOCUMENTATION TO THE SUPERINTENDENT FOR CLARIFICATION, PRIOR TO THE COMMENCEMENT OF THE AFFECTED WORKS.

• THE ARCHITECTURAL DOCUMENTATION IS ONLY ALLOWED

GENERAL NOTES:

0

issue amendment date

scale

drawn

checked drawing no.

drawing

project

issue

project no

client

500 1000 1500 2000 2500

mm

1 : 50@A1

28/04/2020 2:51:36 PM

A190018

MAD HATTER WINE CO, 137PEISLEY STREET, ORANGE NSW

LD

RM

DA0001

EXISTING CONDITIONS ANDDEMOLITION

SCALE: 1 : 50DA0000

1 EXISTING CONDITIONS AND DEMOLITION - ELEVATION

SCALE:

1 : 50

1Z EXISTING CONDITIONS AND DEMOLITION

A UPDATED DA APPLICATION 28.04.20

Page 3: Peisley Street DA - Orange City Council · new fire egress door extent of fire rated cladding to existing wall extent of fire rated cladding to existing wall existing signage private

T

T

T

T

T

T

2DA0002

3DA0002

5DA0002

4DA0002

CANNING

COL.

COL.

COL.

COL.

COLD STORAGECONVERTED REEFER CONTAINER (2440 x 6060)

RAISED FLOOR TO CONCEAL SERVICES

PALLET RACKING

EXISTING CEILING FANS OVER

WINE RACKS

STORE

MICRO-BREWERY

MIC

RO

-BR

EW

ER

Y /

BA

R

ENTRY

MOVEABLE TABLE

MOVEABLE TABLE

PSA AREA173m2

106m2

STILL

1400 1000

4000

1200

2000

1800

RO

LLE

RS

HU

TT

ER

CO

NT

AIN

ER

B

AR

EXISTING FUSE BOX TO BE HOUSED IN FIRE RATED ENCLOSURE

NEW PORATBLE FIRE EXTINGUISHER

UPGRADE EXISTING DOOR TO OPEN OUTWARDS AND MAKE COMPLIANT WITH AS 1428.1

850 M

IN.

NEW EGRESS DOOR

19500

15000

3000

NEW PORATBLE FIRE EXTINGUISHER

ILLUMINATED EXIT SIGN OVER

ILLUMINATED EXIT SIGN OVER

EL

EL EL

EL

INDICATES EMERGENCY LIGHTING OVER TO COMPLY WITH AS2293

SA

INDICATES SMOKE ALARMS OVER TO COMPLY WITH AS3786

SA

5DA0002

REF01 REF01GW01

SNK01

1805 1200

SNK02

40002000

190

880

170

1240

STAINLESS STEEL SPLASHBACK

BIRCH PLY BARTOP

PROPRIETARY STAINLESS STEEL SHELVING

FACE BLOCKWORK

STRUCTURAL PLY FLOOR WITH RESILIANT FINISH

EXISTING CONCRETE SLAB

5DA0002

4DA0002

MICRO-BREWERY PRODUCTION TANKS / STILL BEYOND

PLYWOOD CLADDING TO REEFER CONTAINER

FACE BLOCKWORK BARFRONT WITH BIRCH PLY BARTOP

1240

40

1200

BIRCH PLY BARTOP

FACE BLOCKWORK WALL BEYOND

EXISTING CONCRETE SLAB

MESH INFILL WITH STEEL SUPPORTS

PROPOSED PRODUCER / WHOLESALE AREA

PROPOSED ON-PREMISE WITH PRIMARY SERVICE AUTHORISATION AREA

• ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE STATED.

• REDUCED LEVELS (RL) ARE TO AUSTRALIAN HEIGHT DATUM (AHD). COORDINATES ARE TO MAP GRID AUSTRALIA (MGA).

• DESIGN DRAWINGS ARE BASED ON 3RD PARTY SURVEY INFORMATION. PRIOR TO CONSTRUCTION ALL SET-OUT DIMENSIONS, SITE AND PROPERTY BOUNDARIES, EXISTING LEVELS, STRUCTURE, SERVICES, BUILDING FABRIC AND SITE FEATURES ARE TO BE VERIFIED ON SITE BY A REGISTERED SURVEYOR - INFORMATION PERTAINING TO EXISTING BUILDING FABRIC AND SITE FEATURES, INDICATED WITHIN THE DOCUMENTATION IS NOT GUARANTEED AS COMPLETE OR CORRECT. NOTIFY THE SUPERINTENDENT IN WRITING OF

• THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT CONTRACTS, ARCHITECTURAL DRAWINGS, SCHEDULES, REPORTS AND SPECIFICATIONS, AND ALL STRUCTURAL, CIVIL, MECHANICAL, ELECTRICAL, FIRE ENGINEERING, FIRE SERVICES, HYDRAULIC, ACOUSTIC, LANDSCAPE AND OTHER RELEVANT CONSULTANT DRAWINGS, SPECIFICATIONS AND REPORTS. DO NOT PROCEED TO CONTRACTOR DESIGN, FABRICATION AND/ OR CONSTRUCTION WITHOUT WRITTEN CONFIRMATION THAT ALL CONSULTANT DOCUMENTATION IS ISSUED.

• REPORT ANY DISCREPANCIES BETWEEN THE ARCHITECTURAL DOCUMENTATION AND OTHER CONSULTANT AND/OR PROJECT DOCUMENTATION TO THE SUPERINTENDENT FOR CLARIFICATION, PRIOR TO THE COMMENCEMENT OF THE AFFECTED WORKS.

• THE ARCHITECTURAL DOCUMENTATION IS ONLY ALLOWED

GENERAL NOTES:

0

issue amendment date

scale

drawn

checked drawing no.

drawing

project

issue

project no

client

500 1000 1500 2000 2500

mm

28/04/2020 2:51:44 PM

A190018

MAD HATTER WINE CO, 137PEISLEY STREET, ORANGE NSW

LD

RM

DA0002

FLOOR PLAN

SCALE:

1 : 50

1 FLOOR PLAN

SCALE: 1 : 50DA0002

2 BAR - INTERNAL ELEVATION

SCALE: 1 : 10DA0002

5 BAR SECTION 02

SCALE: 1 : 50DA0002

3 BAR - EXTERNAL ELEVATION

SCALE: 1 : 10DA0002

4 BAR SECTION 01

A UPDATED DA APPLICATION 28.04.20

Page 4: Peisley Street DA - Orange City Council · new fire egress door extent of fire rated cladding to existing wall extent of fire rated cladding to existing wall existing signage private

4DA0003

NEW FIRE RATED TREATMENT TO ACHIEVE 2 HOUR FIRE RATING TO WAREHOUSE WALLS 3m TO EXISTING BOUNDARIES. REMOVE EXISTING POLYCARBONATE SHEETING AND REPLACE WITH COLORBOND STEEL CLADDING AND FIRE RATED PLASTERBOARD. REFER DETAIL.

EXISTING POLYCARBONATE SHEETING RETAINED

EXISTING FACE BLOCKWORK RETAINEDEXISTING ROLLERSHUTTER RETAINED

EXISTING VISION GLAZING RETAINED

NEW FIRE RATED TREATMENT TO ACHIEVE 2 HOUR FIRE RATING TO WAREHOUSE WALLS 3m TO EXISTING BOUNDARIES. REMOVE EXISTING POLYCARBONATE SHEETING AND REPLACE WITH COLORBOND STEEL CLADDING AND FIRE RATED PLASTERBOARD. REFER DETAIL.

3DA0003

Sim

1400

4750

FOLDED COLORBOND TRIM TO BASE OF EXTERNAL FIRE RATED CLADDING

1570

EXISTING STEEL ROOF SHEETING ON SARKING

NEW COLORBOND FASCIA

EXISTING STEEL FRAMED GLAZING RETAINED

EXITING NON-LOAD BEARING SINGLE SKIN FACE BLOCKWORK

EXITING CONCRETE SLAB ON GROUND

2 LAYERS FIRE RATED PLASTERBOARD LINING TO INTERNAL SIDE

COLORBOND STEEL CLADDING OVER 3 LAYERS FIRE RATED PLASTERBOARD EXTERNAL SIDE

1600

PACKER AS REQUIRED

EXISTING TIMBER FRAMING RETAINED. REFER TO DEMOLITION PLANS FOR EXTENT OF POLYCARONATE SHEETING REMOVED.

ALUMINIUM ANGLE TO BASE OF INTERNAL FIRE RATED LINING

LASERCUT CORPORATE BRANDING BACKLIT WITH CONCEALED FIXING

EXISTING SIGNPOLE AND BACKING TO SIGNAGE RETAINED

1560 TBC

1480 T

BC

TRANSLUCENT SHEETING WITH INTEGRATED FLUROESCENT TUBE LIGHTING

• ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE STATED.

• REDUCED LEVELS (RL) ARE TO AUSTRALIAN HEIGHT DATUM (AHD). COORDINATES ARE TO MAP GRID AUSTRALIA (MGA).

• DESIGN DRAWINGS ARE BASED ON 3RD PARTY SURVEY INFORMATION. PRIOR TO CONSTRUCTION ALL SET-OUT DIMENSIONS, SITE AND PROPERTY BOUNDARIES, EXISTING LEVELS, STRUCTURE, SERVICES, BUILDING FABRIC AND SITE FEATURES ARE TO BE VERIFIED ON SITE BY A REGISTERED SURVEYOR - INFORMATION PERTAINING TO EXISTING BUILDING FABRIC AND SITE FEATURES, INDICATED WITHIN THE DOCUMENTATION IS NOT GUARANTEED AS COMPLETE OR CORRECT. NOTIFY THE SUPERINTENDENT IN WRITING OF

• THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT CONTRACTS, ARCHITECTURAL DRAWINGS, SCHEDULES, REPORTS AND SPECIFICATIONS, AND ALL STRUCTURAL, CIVIL, MECHANICAL, ELECTRICAL, FIRE ENGINEERING, FIRE SERVICES, HYDRAULIC, ACOUSTIC, LANDSCAPE AND OTHER RELEVANT CONSULTANT DRAWINGS, SPECIFICATIONS AND REPORTS. DO NOT PROCEED TO CONTRACTOR DESIGN, FABRICATION AND/ OR CONSTRUCTION WITHOUT WRITTEN CONFIRMATION THAT ALL CONSULTANT DOCUMENTATION IS ISSUED.

• REPORT ANY DISCREPANCIES BETWEEN THE ARCHITECTURAL DOCUMENTATION AND OTHER CONSULTANT AND/OR PROJECT DOCUMENTATION TO THE SUPERINTENDENT FOR CLARIFICATION, PRIOR TO THE COMMENCEMENT OF THE AFFECTED WORKS.

• THE ARCHITECTURAL DOCUMENTATION IS ONLY ALLOWED

GENERAL NOTES:

0

issue amendment date

scale

drawn

checked drawing no.

drawing

project

issue

project no

client

500 1000 1500 2000 2500

mm

As indicated@A1

28/04/2020 2:51:45 PM

A190018

MAD HATTER WINE CO, 137PEISLEY STREET, ORANGE NSW

LD

RM

DA0003

ELEVATION, SECTION + DETAILS

SCALE: 1 : 50DA0000

1 EAST ELEVATIONSCALE: 1 : 5DA0000

3 FIRE RATED CLADDING DETAIL

SCALE: 1 : 20DA0003

4 PROPOSED SIGNAGE DETAIL

A UPDATED DA APPLICATION 28.04.20