  • 8/11/2019 Performancemeasurementprotocols Comm Bldgs

    1/15

    Performance Measurement Protocol (PMP)

    for Commercial Buildings

    Acoustics in High Performance Buildings

    Presented By:

    Curt Eichelberger, P.E.Sr. Staff Engineer, Acoustics & VibrationBuilding Efficiency

    Johnson Controls

    631 South Richland Avenue

    York, PA 17403

    [email protected]

    ASHRAE Winter Conference

    Orlando, Florida1/24/2010

  • 8/11/2019 Performancemeasurementprotocols Comm Bldgs

    2/15

    ASHRAEisaRegisteredProviderwithTheAmericanInstituteofArchitectsContinuingEducation

    Systems.

    Credit

    earned

    on

    completion

    of

    this

    program

    will

    be

    reported

    to

    ASHRAE

    Records

    for

    AIA

    members. CertificatesofCompletionfornonAIAmembersareavailableonrequest.

    This

    program

    is

    registered

    with

    the

    AIA/ASHRAE

    for

    continuing

    professional

    education.

    As

    such,

    it

    does

    not

    include

    content

    that

    may

    be

    deemed

    or

    construed

    to

    be

    an

    approval

    or

    endorsement

    by

    the

    AIA

    of

    any

    material

    of

    construction

    or

    any

    method

    or

    manner

    of

    handling,

    using,

    distributing,

    or

    dealing

    in

    any

    material

    or

    product.

    Questions

    related

    to

    specific

    materials,

    methods,

    and

    services

    will

    be

    addressed

    at

    the

    conclusion

    of

    this

    presentation.

    LearningObjectivesforSeminar#1

    To understand acoustic measurement protocols for the operationalperformance measurement of occupied commercial buildings.

    How to take noise measurements in a room.

    To understand how to benchmark the acoustic performance of green

    buildings. To communicate a basic understanding of the acoustical measurements

    used in the three levels of the PMP.

    How to use the Innovation in Design Credit process for application to

    superior acoustic design and performance.

    How standard architectural design currently performs relative to the

    occupants perception of acoustic satisfaction in buildings.

  • 8/11/2019 Performancemeasurementprotocols Comm Bldgs

    3/15

    3

    Buildings in the US, Europe and most

    developed economies are responsible for

    over 40% of national energy use.

    Focus on energy conservation has

    created an intense interest in the design and

    operation of high performance buildings.

    First voluntary USGBC LEED GreenBuilding Rating System launched 2000.

    Background

    Performance Measurement Protocol (PMP) for Commercial Bui ldings

  • 8/11/2019 Performancemeasurementprotocols Comm Bldgs

    4/15

    4

    Many buildings which are claimed to be low energy, or high performance

    have no evidence to support these claims.

    Major credibility gap between design intent and the reality of everydayoperation of many of high-performance buildings.

    Claims of high performance designs cannot be credible without standardized

    protocols for the assessment of building performance.

    Claims of better management of buildings, and hence reduced operating

    costs, requires better measurements of their performance.

    What is our Experience with High Performance Buildings ?

    In summary: you cant manage what you cant measure.In summary: you cant manage what you cant measure.

    Performance Measurement Protocol (PMP) for Commercial Bui ldings

  • 8/11/2019 Performancemeasurementprotocols Comm Bldgs

    5/15

    5

    Of all the interior environmental quality (IEQ) factors surveyed in over

    300 buildings by the CBE , the factor with the greatest occupant

    dissatisfaction is acoustic performance, which includes both noise and

    speech privacy related issues.

    We are compromising worker comfort and productivity for energy

    efficiency.

    What about the Acoustics Experience of High Performance Buildings ?

    Performance Measurement Protocol (PMP) for Commercial Bui ldings

  • 8/11/2019 Performancemeasurementprotocols Comm Bldgs

    6/15

    6

    In the spring of 2005 the USGBC approached ASHRAE to develop

    performance measurement protocols for buildings.

    ASHRAE responded with SP115 within Technology Council,

    overseen by the Building Performance Metrics Steering Committee.

    In August 2007, ASHRAE completed a survey of over 400

    documents, with the help of expert interviews, to determine their

    relevance to measurement protocols.

    In February 2008, ASHRAE formed a committee of industry

    experts to develop Performance Measurement Protocols (PMP)

    document.

    Today, a final draft of the PMP is with the ASHRAE SpecialPublications editorial staff. It will likely be published in Feb. or March,

    2010.

    What is ASHRAEs Response to this Situation ?

    Performance Measurement Protocol (PMP) for Commercial Bui ldings

  • 8/11/2019 Performancemeasurementprotocols Comm Bldgs

    7/15

    7

    Cooperative effort between:

    American Society of Heating, Refr igerating and Air-Conditioning Engineers

    U.S. Green Bui lding Counci l (USGBC)

    Chartered Institute of Building Services Engineers (CIBSE)

    International focus, with experts and representation from many countries.

    The purpose of the PMP is to provide standardized protocols for measuring

    energy use, water use, and indoor environmental quality (IEQ: thermal comfort,indoor air quality - IAQ, lighting, acoustics).

    Scope restricted to the performance of occupied commercial buildings.

    Target audience is building owners, operators and designers.

    Later versions are likely to become an ASHRAE Guideline or Standard.

    What is the Performance Measurement Protocol (PMP) ?

    Performance Measurement Protocol (PMP) for Commercial Bui ldings

  • 8/11/2019 Performancemeasurementprotocols Comm Bldgs

    8/15

    8

    Six performance categories are covered:

    Energy

    WaterThermal comfort

    IAQ

    LightingAcoustics

    What should be measured ?

    Performance Measurement Protocol (PMP) for Commercial Bui ldings

  • 8/11/2019 Performancemeasurementprotocols Comm Bldgs

    9/15

    9

    For each category the following are provided:

    What is to be measuredHow it is to be measured

    Where it is to be measured

    How often it is to be measured

    Benchmarks to evaluate the results

    The measurement protocol include both subjective measures (e.g., occupant

    surveys), and objective (physical) measures

    What should be measured ?

    Performance Measurement Protocol (PMP) for Commercial Bui ldings

  • 8/11/2019 Performancemeasurementprotocols Comm Bldgs

    10/15

    10

    Each of the six measurement categories are developed at three levels, with a

    hierarchy of low, medium and high cost and accuracy

    Level 1 (Basic) protocols are simple, low cost, measures

    Level 2 (Intermediate) provides further data on performance.

    Level 3 (Advanced) offers a very detailed analysis & diagnostics.

    A Three layered approach recognizes economic realities

    Performance Measurement Protocol (PMP) for Commercial Bui ldings

  • 8/11/2019 Performancemeasurementprotocols Comm Bldgs

    11/15

  • 8/11/2019 Performancemeasurementprotocols Comm Bldgs

    12/15

    12

    Acoustic performance requirements depend on the types of activities that

    occupants engage in during their time spent in these spaces. Examples:

    Open off ice planPrivate offices

    Classrooms

    Hospital examination rooms

    Theaters

    Hotel rooms

    In most commercial buildings, the key issues relate to worker productivity and

    confidentiality of sensitive information.

    In hotels and motels, the key issues relate to sleeping conditions and inter-roomprivacy.

    IEQ Acoustics

    Performance Measurement Protocol (PMP) for Commercial Bui ldings

  • 8/11/2019 Performancemeasurementprotocols Comm Bldgs

    13/15

    13

    Overview of Acoustic Measures and Concerns

    Measures Comments Concerns

    BASIC

    Annoyance

    Study and work performanceSleep and relaxation

    Speech privacy and

    Speech communication

    ADVANCED

    INTERMED

    IATE

    Survey of the A-weighted sound

    pressure level in the occupied spaces,Leq in dB(A)

    Simple evaluation of background noise from

    internal HVAC equipment and intrudingnoise from outside HVAC equipment and

    transportation noise sources, such as

    highway traffic, rail vehicles and aircraft.

    Annoyance

    Study and work performance

    Sleep and relaxation

    Listening conditions

    Privacy

    Annoyance

    Study and work performance

    Listening conditionsPrivacy

    Speech privacy and communication

    (AI, PI, SII, and STI)

    For special purpose room uses such as

    some open office plans, lecture halls,

    classrooms, places of worship and

    performing arts facilities.

    Sound isolation

    (NIC, IIC, DnT ,w and L'nT ,w).

    Isolation from outside noise by the building

    envelope, and sound/vibration isolation

    between interior rooms.

    Accurate assessment of the

    background sound in occupied spaces,

    Leqin dB in Octave Bands.

    Comparison with single number ratings

    such as NC, RC and NCB, based on a

    more accurate analysis of the sound qualityby room use.

    Reverberation time (T60) General assessment of speech

    communication issues.

    Table 1-1. Overview of the acoust ic concerns and the methods of measuring the

    acoustic performance in commercial buildings as a function of the use of the space.

    Performance Measurement Protocol (PMP) for Commercial Bui ldings

  • 8/11/2019 Performancemeasurementprotocols Comm Bldgs

    14/15

    14

    The Basic protocol is a simple survey to assess the acoustic annoyance that

    would affect study and work performance, as well as sleep and relaxation.

    an occupant survey to identify acoustical problems in the building

    a survey of the A-weighted sound pressure level Leq in dB(A)

    The Intermediate protocol is an accurate assessment of the background

    noise and reverberation time in a room. The objective is to assess acoustic

    annoyance that would affect study and work performance, as well as speechcommunication and listening conditions.

    theAdvanced protocol is an accurate assessment of speech privacy and

    sound isolation for special applications or designs that claim to meet high levels

    of acoustic performance.

    Overview of Three Levels of Performance Measures - Acoustics

    Performance Measurement Protocol (PMP) for Commercial Bui ldings

  • 8/11/2019 Performancemeasurementprotocols Comm Bldgs

    15/15

    Performance Measurement Protocol (PMP) for Commercial Bui ldings15

    Questions?