photochem colorimeters - aimil ltd....91-11-30810200/45/46 91-11-2695 0011 [email protected] due to...

2
Photochem Colorimeters Principle : Light from a broad spectrum LED is focused through an unique optical system a filter test tube to the photocell. Output from the photocell is fed into an amplifier and the output of the amplifier to the Digital Panel Meter (DPM). A set of filters, enabling a wide range of range of analytical tests, are mounted on a turret so that the required filter can easily be selected. The operation of the unit is very simple, the user needs to adjust display 0.00 OD or 100% T with blank and then take the reading of the identified standard / sample with Auto Zero facility. The microprocessor based unit when opted for, provides multiple facilities within the same compact size with Auto Zero facility. Salient Features : Small convenient, sample size of 1 ml only Long life broad spectrum LED light source Very few controls for ease of operation Compact design Available various digital models: Photochem 8 filter, Photochem 8 filter mains/battery, OD only with Auto Zero Microprocessor based Photochem 8 filter with Auto Zero facility/OD/T/C. Applications : Biochemistry Clinical Laboratory Pathology Clinical Pathology Water Analysis Soil Analysis Metallurgy Photochem 8 Microprocessor Auto Zero Photochem Micro 8 Auto Zero

Upload: others

Post on 11-Aug-2020

17 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Photochem Colorimeters - Aimil Ltd....91-11-30810200/45/46 91-11-2695 0011 salespei@aimil.com Due to Aimil's policy of continuous development, specifications are subject to change

Photochem Colorimeters

Principle :

Light from a broad spectrum LED is focused through an unique optical system a filter test tube to the photocell. Output from the photocell is fed into an amplifier and the output of the amplifier to the Digital Panel Meter (DPM).

A set of filters, enabling a wide range of range of analytical tests, are mounted on a turret so that the required filter can easily be selected.

The operation of the unit is very simple, the user needs to adjust display 0.00 OD or 100% T with blank and then take the reading of the identified standard / sample with Auto Zero facility.

The microprocessor based unit when opted for, provides multiple facilities within the same compact size with Auto Zero facility.

Salient Features :

Small convenient, sample size of 1 ml only

Long life broad spectrum LED light source

Very few controls for ease of operation

Compact design

Available various digital models:

Photochem 8 filter, Photochem 8 filter mains/battery, OD only with Auto Zero

Microprocessor based Photochem 8 filter with Auto Zero facility/OD/T/C.

Applications :

Biochemistry

Clinical Laboratory

Pathology

Clinical Pathology

Water Analysis

Soil Analysis

Metallurgy

Photochem 8 Microprocessor Auto Zero

Photochem Micro 8 Auto Zero

Page 2: Photochem Colorimeters - Aimil Ltd....91-11-30810200/45/46 91-11-2695 0011 salespei@aimil.com Due to Aimil's policy of continuous development, specifications are subject to change

Aim

il/A

&I/P

EI-

PC

/14

-15

/01

/02

M

arC

om

Cre

atio

n

For further information, please contact us :

Corporate Office :

"Naimex House"

A-8, Mohan Co-operative

Industrial Estate, Mathura Road,

New Delhi-110044

E-mail : [email protected]

Also Offices at : • Mumbai • Bengaluru • Kolkata • Chennai • Vadodara • Hyderabad • Chandigarh • Guwahati • Nagpur • Bhubaneswar • Indore

Resident Representatives : • Kochi • Lucknow

[email protected] 001191-11-30810200/45/46

Due to Aimil's policy of continuous development, specifications are subject to change without prior notice.

Cat No. Eight Filter Models

018000 Auto Zero Digital Micro Photochem 8 Filter with optical density scale only with Auto Zero.

018100 Auto Zero Digital Microprocessor based Photochem 8 Filter with Auto Zero, % T, OD, Concentration scales.

018200 Auto Zero Digital Micro Photochem 8 Filter with mains / battery operation with built in Ni-Cad rechargeable batteries with optical density scale only with Auto Zero.

Digital Micro 8 Filter with Auto Zero

Digital Micro 8 Filters battery model with Auto Zero

Digital Microprocessor 8 Filter Auto Zero %Transmission Optical Density, Concentration

Peak transmission wavelengths

Detector

Lamp source

Lamp source regulation

Filters

Power requirements

Dimensions

Nett weight for micro models

Bright 7 segment LED display Optical Density -0.20 t0 1.99

Bright 7 segment LED display Optical Density -0.20 to 1.99 Built in Ni-Cad rechargeable battery pack with automatic changeover from mains to battery with suitable indicators

Bright 7 segment LED display, Displays function and the reading associated with function selected displays%T : 0 to 130OD : -0.11 to 1.99C1 : 000 to 999C2 : 00.0 to 99.9Last used "K" factor retained in memory even after power "OFF"

430, 470, 490, 520, 550, 580, 610 and 700nm

Sealed high sensitivity silicon photocell

Long life, broad spectrum LED

Fully stabilized. Deviation not more than ± 1% of 100% T. For mains variation between 190 to 250 V, 50 Hz

Hermetically sealed gelatin filters covering visible spectrum

Approximately 5 Watts At 220V / 50 Hz

25 x 19 x 10 cm

1.5 Kg

All Eight Filter Models

Specifications:

Ordering Information