Photochem Colorimeters
Principle :
Light from a broad spectrum LED is focused through an unique optical system a filter test tube to the photocell. Output from the photocell is fed into an amplifier and the output of the amplifier to the Digital Panel Meter (DPM).
A set of filters, enabling a wide range of range of analytical tests, are mounted on a turret so that the required filter can easily be selected.
The operation of the unit is very simple, the user needs to adjust display 0.00 OD or 100% T with blank and then take the reading of the identified standard / sample with Auto Zero facility.
The microprocessor based unit when opted for, provides multiple facilities within the same compact size with Auto Zero facility.
Salient Features :
•
•
•
•
•
Small convenient, sample size of 1 ml only
Long life broad spectrum LED light source
Very few controls for ease of operation
Compact design
Available various digital models:
Photochem 8 filter, Photochem 8 filter mains/battery, OD only with Auto Zero
Microprocessor based Photochem 8 filter with Auto Zero facility/OD/T/C.
Applications :
•
•
•
•
•
•
•
Biochemistry
Clinical Laboratory
Pathology
Clinical Pathology
Water Analysis
Soil Analysis
Metallurgy
Photochem 8 Microprocessor Auto Zero
Photochem Micro 8 Auto Zero
Aim
il/A
&I/P
EI-
PC
/14
-15
/01
/02
M
arC
om
Cre
atio
n
For further information, please contact us :
Corporate Office :
"Naimex House"
A-8, Mohan Co-operative
Industrial Estate, Mathura Road,
New Delhi-110044
E-mail : [email protected]
Also Offices at : • Mumbai • Bengaluru • Kolkata • Chennai • Vadodara • Hyderabad • Chandigarh • Guwahati • Nagpur • Bhubaneswar • Indore
Resident Representatives : • Kochi • Lucknow
[email protected] 001191-11-30810200/45/46
Due to Aimil's policy of continuous development, specifications are subject to change without prior notice.
Cat No. Eight Filter Models
018000 Auto Zero Digital Micro Photochem 8 Filter with optical density scale only with Auto Zero.
018100 Auto Zero Digital Microprocessor based Photochem 8 Filter with Auto Zero, % T, OD, Concentration scales.
018200 Auto Zero Digital Micro Photochem 8 Filter with mains / battery operation with built in Ni-Cad rechargeable batteries with optical density scale only with Auto Zero.
Digital Micro 8 Filter with Auto Zero
Digital Micro 8 Filters battery model with Auto Zero
Digital Microprocessor 8 Filter Auto Zero %Transmission Optical Density, Concentration
Peak transmission wavelengths
Detector
Lamp source
Lamp source regulation
Filters
Power requirements
Dimensions
Nett weight for micro models
Bright 7 segment LED display Optical Density -0.20 t0 1.99
Bright 7 segment LED display Optical Density -0.20 to 1.99 Built in Ni-Cad rechargeable battery pack with automatic changeover from mains to battery with suitable indicators
Bright 7 segment LED display, Displays function and the reading associated with function selected displays%T : 0 to 130OD : -0.11 to 1.99C1 : 000 to 999C2 : 00.0 to 99.9Last used "K" factor retained in memory even after power "OFF"
430, 470, 490, 520, 550, 580, 610 and 700nm
Sealed high sensitivity silicon photocell
Long life, broad spectrum LED
Fully stabilized. Deviation not more than ± 1% of 100% T. For mains variation between 190 to 250 V, 50 Hz
Hermetically sealed gelatin filters covering visible spectrum
Approximately 5 Watts At 220V / 50 Hz
25 x 19 x 10 cm
1.5 Kg
All Eight Filter Models
Specifications:
Ordering Information