pidiagram-130803012111-phpapp02
DESCRIPTION
jjjkjjTRANSCRIPT
Slide 1
MReactant APID-1 FAFrom 01P001A/B25NBDrainXV030180-FA-03-01-XA1I03.180-FA-01-12-XA1N1N4N550NB50NB50NBN8LT030125NBDrainLI0301LAL0301LAH0301LSH0301I03.1N780NBN6Reactant APID-1 FATo 01T001N2N325NBDrain25NBDrainXV030250-FB-03-06-XB1I03.3Reactant BPID-2 FBFrom 02P001A/B50-FB-02-21-XB1N8LT030225NBDrainLI0302LAL0302LAH0302LSH0302I03.380NBReactant APID-4 FATo 03R001B/C/D25NBDrainFCV030150-FA-03-03-XA1FT0301FIC0301FAH0301FAL0301FY0301I03.2CR50X25CR50X25CR50X40CR50X4025-FA-03-12-XA1100-FA-03-09-XA150-FA-03-02-XA1Waste GasesPID-9 FGTo 05C001100-FG-03-10-XG1Process WaterPID-8 PWFrom 08P002A/B40-PW-12-15-XP125-PW-03-08-XP1N1N2N7N6N4N5Cooling WaterPID-7 CWFrom 07P001A/BN1050-CW-10-17-XC1N9Cooling WaterPID-7 CWTo 07U00115NBVentTI0302TE0302CR80X50CR80X5050-CW-03-07-XC1Product SlurryPID-4 FPTo 04T001N3Hose25NB100-FP-03-11-FP1TI0301TE0301TW1TAL0301TAH0301TSHH0301I03.2EL +19.300MEL + 6.300M03T00103R001A03R001AN0150NB50-FA-03-05-XA150-FA-03-04-XA1Koncept Learning Center
[email protected] & I Diagram1
Koncept Learning Center
[email protected] & I DiagramLiquid Storage2
Koncept Learning Center
[email protected] & I DiagramT-201P-201 AP-201 BWEF1WEF1WEF1N1N2N3N4 N5N6100 NBFrom P-101 A/BTo T-301 L1006-100-FA-XA1PID-1PID-6L2001-100-FA-XA1L2002-100-FA-XA1L2003-80-FA-XA1L2004-80-FA-XA1ER100x80ER100x80CR80x65CR80x65PWPWN7DSPPI201BPI201ALI201 50 NBFT201L2005-80-FA-XA1FCV201FIC201FAH201FAL201FSHH201I.1I.1I.1L2006-65-FA-XA1Liquid Storage P & I Diagram3Koncept Learning Center
[email protected] & I DiagramT-201N1N2N3N4 N5N6100 NBN7 50 NBP-201 AP-201 BEquipment 4Koncept Learning Center
[email protected] & I DiagramT-201P-201 AP-201 BWEF1WEF1WEF1N1N2N3N4 N5N6100 NBFrom P-101 A/BTo T-301 L1006-100-FA-XA1PID-1PID-6L2001-100-FA-XA1L2002-100-FA-XA1L2003-80-FA-XA1L2004-80-FA-XA1ER100x80ER100x80CR80x65CR80x65PWPWN7DSP 50 NBEquipment , Piping 5Koncept Learning Center
[email protected] & I DiagramT-201P-201 AP-201 BWEF1WEF1WEF1N1N2N3N4 N5N6100 NBFrom P-101 A/BTo T-301 L1006-100-FA-XA1PID-1PID-6L2001-100-FA-XA1L2002-100-FA-XA1L2003-80-FA-XA1L2004-80-FA-XA1ER100x80ER100x80CR80x65CR80x65PWPWN7DSPPI201BPI201ALI201 50 NBFI201L2005-80-FA-XA1Equipment , Piping & Instrument 6Koncept Learning Center
[email protected] & I DiagramEquipment , Piping & Instrument (With Automation)T-201P-201 AP-201 BWEF1WEF1WEF1N1N2N3N4 N5N6100 NBFrom P-101 A/BTo T-301 L1006-100-FA-XA1PID-1PID-6L2001-100-FA-XA1L2002-100-FA-XA1L2003-80-FA-XA1L2004-80-FA-XA1ER100x80ER100x80CR80x65CR80x65PWPWN7DSPPI201BPI201ALI201 50 NBFT201L2005-80-FA-XA1FCV201FIC201FAH201FAL201FSHH201I.1I.1I.1L2006-65-FA-XA17Rev.No.
0PROJECT
05001DRAWING NUMBER
PID 05001 01 - 101P & I DrawingFor Material Storage Code No.T-201P-201 A/B DescriptionStorage TankTransfer PumpR Description Drn Chkd Appd Dt.Client : M/s ABC Co.Plant : 30 TPD of Product PLocation : Pune (Maharashtra)Notes: 1) 2) 3)T-201P-201 AP-201 BWEF1WEF1WEF1N1N2N3N4 N5N6100 NBFrom P-101 A/BTo T-301 L1006-100-FA-XA1PID-1PID-6L2001-100-FA-XA1L2002-100-FA-XA1L2003-80-FA-XA1L2004-80-FA-XA1ER100x80ER100x80CR80x65CR80x65PWPWN7DSPPI201BPI201ALI201 50 NBFI201L2005-80-FA-XA1Koncept Learning Center
[email protected] Training Workshop Write us at : [email protected] P & I Diagram8