No Issues Ratings Findings Recommendations Agreed Corrective Action
1
C P&ID - HO Launcher and Receiver
2 C Exhibit I - Clause 5.1 h) PMT to recheck the requirements
3 C Exhibit I - Clause 10.19.7 PMT to revise the base total points
4 C Exhibit I - Clause 9.11 PMT to include 3rd party approved list
5 Welding consumables C
6 C Reword
Evidence/Reference/Supporting Info
Coating design maximum operating temperature
Based on Note #24, it is stated that coating designed for maximum operating temperature is 70⁰C but it is different compare to temperature stated in equipment maximum operating temperature
It should reflect to maximum design temperature @ 83⁰C for aboveground components and 75⁰C for buried components
Report for welding and NDT shall be approved by 3rd parties
As per SOC requirements, all reports related to welding and NDT shall be approved by 3rd parties registered with SOC. Thus, this will imposed additional time and cost or it may come as HOLD point on site progress especially where testing require welding & NDT report
Thickness Measurement Plan Baseline Survey
PMT to revise the base total points approximately 100 points
Approved 3rd party by SOC
It is stated that the required inspection shall be performed by qualified 3rd pary inspectors emloyed by CONTRACTOR and duly approved by PCIHBV but none mentioned on approved 3rd party approved by SOC
It is not mentioned any wrt consumables shall be approved/certified by 3rd party
Exhibit I - Clause 11.14.1.1.2, VI, d) Welding Consumables
Contractor to ensure that all welding consumables shall be approved/registered by 3rd party
Qualification of welding procedures
To reword the draft WPS to preliminary WPS
Exhibit I - Clause 11.14.1.1.2, VI, f) Qualification of welding procedures
![Page 2: PIR Export Pipeline MCI QAQC](https://reader035.vdocuments.net/reader035/viewer/2022071709/55cf8efd550346703b97cbd3/html5/thumbnails/2.jpg)
EPCC of Kepodang Project <DISCIPLINE>
PROJECT INDEPENDENT REVIEW(PIR) 02 03 KEPODANG PROJECT28 October - 2 November 2013
Page 2
No Issues Ratings Findings Recommendations Agreed Corrective ActionEvidence/Reference/Supporting
Info
7 C To include this requirement
8 C The density shall be between 1.8 to 4.0
9 C PMT to recheck the requirements
10 C EPC SOW for CP
11 Priced PO C Exhibit I - Clause 13.0
12 Exhibit VII C Exhibit VII PMT to replace
Qualification of welding procedures
It is not mentioned any wrt WPS shall be approved by 3rd party
Exhibit I - Clause 11.14.1.1.2, VI, f) Qualification of welding procedures
Film density acceptable range
The RT density shall be greater than 2.0 and less than 3.0 on the weld area adjacent to the root
Exhibit I - Clause 11.14.1.1.2, VII Film density
Report for welding and NDT shall be approved by 3rd parties
As per SOC requirements, all reports related to welding and NDT shall be approved by 3rd parties registered with SOC. Thus, this will imposed additional time and cost or it may come as HOLD point on site progress especially where testing require welding & NDT report
Exhibit I - Clause 11.14.1.1.2, VII Welding and NDT reports
Anode drain stations, shielding or resistance bond station to eliminate effect of CP interference to existing pipeline
CONTRACTOR shall include copies of priced purchase orders for the following items, in the Final Documentation:• Mechanical EQUIPMENT;• Electrical EQUIPMENT;• Instrumentation EQUIPMENT.
What is the relevancy of this statement? Thus previous package applied and was provided with price PO?
To replace Exhibit VII to new and amended Exhibit
![Page 3: PIR Export Pipeline MCI QAQC](https://reader035.vdocuments.net/reader035/viewer/2022071709/55cf8efd550346703b97cbd3/html5/thumbnails/3.jpg)
EPCC of Kepodang Project <DISCIPLINE>
PROJECT INDEPENDENT REVIEW(PIR) 02 03 KEPODANG PROJECT28 October - 2 November 2013
Page 3
No Issues Ratings Findings Recommendations Agreed Corrective ActionEvidence/Reference/Supporting
Info
Good Practices 0Rating A 0Rating B 0Rating C 11