piston distributor lubrication using oil - lube systems of ...lubesystemsonline.com/graco/graco...

36
© LUBRIQUIP, INC., 1998. All Rights Reserved. Piston Distributor Lubrication Using Oil Injecto-Flo ® Piston Distributor System Components LUBRIQUIP BY ® Bulletin 12120 Product Specs and Ordering Revised August 2000

Upload: truongtram

Post on 20-Mar-2018

222 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

© LUBRIQUIP, INC., 1998. All Rights Reserved.

Piston Distributor

Lubrication

Using Oil

Injecto-Flo®

Piston Distributor System Components

LUBRIQUIPBY ®

Bulletin 12120

Product Specs and Ordering

Revised August 2000

Page 2: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less
Page 3: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

R

12120

i

AC

CE

SS

OR

IES

Table of Contents

Introduction/Components/Features ....................................................................... 1

System Operation ................................................................................................. 2

Hand Operated Pump ........................................................................................... 3

Air Operated Pumps ............................................................................................. 4

Electric Motor Driven Pumps............................................................................ 5 - 8

Piston Distributors ........................................................................................... 9 -11

Manifolds and Manifold Accessories ............................................................ 11 - 12

Piston Distributors (Push to Connect) ................................................................. 13

Piston Distributors (Bearing Point) ...................................................................... 14

Piston Distributors (Post Fire) ...................................................................... 15 - 16

Electrical Controls ........................................................................................ 17 - 21

Pressure Switch .................................................................................................. 22

Pressure Gauges ................................................................................................ 22

Filters .................................................................................................................. 22

Anchor Blocks ..................................................................................................... 23

Manifolds ............................................................................................................. 24

Tube Fittings (Threaded) ............................................................................. 25 - 26

Tube Fittings (Push to Connect) .................................................................. 27 - 28

Tube Clips ........................................................................................................... 28

Tubing ................................................................................................................. 28

Hose Assemblies ................................................................................................ 28

Lubriquip Systems .............................................................................................. 29

Index ................................................................................................................... 30

Page 4: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

R

Injecto-Flo® Piston Distributor System Components

ii

Page 5: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 1

12120Injecto-Flo® Piston Distributor System Components

Injecto-Flo Piston Distributor Systems utilize one of three

types of pumps: A single-stroke hand-operated pump; a

single-stroke, air-operated pump: or a continuous flow,

electric motor driven pump. Pump output is delivered to

piston distributors which dispense precise amounts of

lubricating oil to the bearing points. Air-operated pumps

require a solenoid-operated air valve and controller to

activate the pump. Electric motor driven pumps use an

electric motor and built in, or remote timer device to activate

the pump. The Piston Distributors are mounted in manifolds

supplied by Lubriquip. The bearing point type mount at the

bearing point and require no manifold. Various accessories

are available to simplify installation. An optional pressure

switch or gauge may be added at the pump outlet port, if

desired, to monitor pump operation.

SYSTEM COMPONENTS

PumpsPositive displacement, hand-operated pumps, air-operated

pumps and electric motor driven pumps are available with

metal or plastic reservoirs allowing a system to be designed

precisely for the application needs.

Timer

The Solid-state timer can be set to control pump run duration

and to initiate lube cycles at intervals from 30 seconds to 32

hours. Other optional controllers schedule lube intervals on

time, or machine usage. The LC-1000, can control and

monitor pump run duration based on input from a pressure

switch.

Manifolds and Piston Distributors

One manifold can distribute lubricant to as many as 10 lube

points. Piston Distributors come in seven outputs to meet

various lube requirements. Bearing point piston distributors

are fed directly from the pump through individual branch lines

and do not require a manifold.

Tubing, Hardware, Fittings and

Accessories

Injecto-Flo Piston Distributor Systems utilize metric tubing

(metal or nylon) and brass fittings. Adapters are available to

allow the use of inch size tubing where preferred.

FEATURES/BENEFITS

Injecto-Flo Piston Distributors offer an efficient method of

applying lubricant, resulting in less machine downtime,

increased productivity, and a safer work environment.

Injecto-Flo Systems go beyond these advantages to provide:

� Easy system design and modification.

� Inexpensive components and installation.

� Fast payback! Savings in lube maintenance;

man-hours usually pay for the system within the first year.

� Steel reservoir available for heavy-duty use.

� Pump construction internally vents system pressure,

requiring no extra cost external vent valves.

� Hand, air and electric powered pumps available with

several reservoir sizes to fit a wide variety of applications.

� Motors and low level switches meet EEC requirements

(CE mark compliance).

SYSTEM DESCRIPTION

The Injecto-Flo Piston Distributor System is a single-line,

parallel type. When the solid-state timer, controller, or

operator activates the pump, lubricant is forced down a

single main line to manifolds, and from there through

individual piston distributors and lines to the lube points.

If bearing point piston distributors are used, manifolds are

not required. Instead, the single main line branches into

individual lines feeding the bearing point piston distributors.

In both cases, the piston distributors dispense lubricant to a

bearing. Once lubricant is dispensed at the lube points,

system pressure is vented by the pump. This allows the

piston distributors to prime themselves in preparation for the

next lubrication cycle.

INTRODUCTION

Page 6: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 2

Injecto-Flo® Piston Distributor System Components 12120

SYSTEM OPERATION

As shown in Figure 1, when the operator actuates the

handle, or when the solenoid-operated air valve, or electric

motor receives a signal from the timer, the pump is activated.

The pump dispenses lubricant either into the mainline tubing

which distributes the lubricant to the manifolds, feeding each

piston distributor or lines supplying bearing point piston

distributors. Each of the piston distributors is sized to

measure and dispense the proper amount of lubricant based

on the requirements of the bearing. Details of the operation

of each component are included in this bulletin.

InterchangeabilityTrabon components are functionally interchangeable with

other commonly used single-line, parallel piston distributor

systems. Mounting dimensions of the components are very

close to those of other systems, and for some components

there is a direct interchangeability in form and fit as well as

function.

ApplicationsTrabon Piston Distributor Systems are ideal for small to large

machine tools and other equipment requiring economical,

intermittent, oil lubrication.

BEARING

HAND-OPERATED

PUMP

SEE PAGE 3

ELECTRIC

MOTOR

PUMP

SEE PAGES

5 THROUGH 8

BEARING

TUBING AND HOSE

SEE PAGE 28

BEARING POINT

PISTON

DISTRIBUTORS

SEE PAGE 14

MANIFOLD

SEE PAGE 11 & 24

PISTON DISTRIBUTORS

SEE PAGES 9

THROUGH 13

Figure 1

Injecto-Flo Piston Distributor System Diagram

ANCHOR FITTINGS

SEE PAGE 23

FITTINGS AND ADAPTERS

SEE PAGES 23-28

FILTER

SEE PAGE 22

SOLENOID-OPERATED

AIR VALVE

AIR-OPERATED

PUMP

SEE PAGE 4

Page 7: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 3

12120Injecto-Flo® Piston Distributor System Components

HAND-OPERATED PUMP (HO-1)

DESCRIPTION / OPERATION

The HO-1 hand pump (Figure 2) is a positive displacement,

single stroke pump that delivers up to 13cc (.80 in.3) against

a maximum system pressure of 30 bar (435 psi). As the

handle is pulled back, a return spring is compressed and

pump flow is delivered to the system mainline. As mainline

pressure builds, the individual piston distributors dispense a

measured volume of lubricant to the bearing points. When

the handle return to the rest position, the pump piston moves

back to the prime position. Simultaneously, mainline

pressure is vented allowing the piston distributors to re-prime

in preparation for the next lube cycle.

Replacement Outlet Nut 6mm Tube 435-702-466

Replacement Outlet Ferrule 6mm Tube 435-702-421

Figure 2 Hand-Operated Pump

Figure 3

DIMENSIONS

mm/(inches)

31

0.0

(12

.20

)6

.5

(.26)

6mm TUBE

(M12 x 1)

LUBE

OUTLET

72.0

(2.83)

SPECIFICATIONS

Material: ........... Steel and Aluminum Pump, Translucent

Polypropylene Reservoir

Output (Max.): .......................... 13cc (0.80in.3) per stroke

Pressure (Max.): ...................................... 30 bar (435 psi)

Relief valve protected

Oil Viscosity: ................. ISO 50 - 1000 (250 - 5000 SUS)

Rest Time Between Cycles (Min.): .................15 seconds

Time at Pressure (Min.): ...................................5 seconds

Note: Due to the single stroke operation of this pump,

total system discharge volume must not exceed 50% of

pump delivery 6.5cc (0.40in.3).

110.0

(4.33)

17

0.0

(6.7

0)

17.0

(.67)

51

.0

(2.0

0)

80.0

(3.15)

29.0

(1.14)

Ordering Information

Table 1

Reservoir

Capacity Material Part Number

1 liter (2 pt) Plastic 550-151-100

36

.0

(1.4

2)

Page 8: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 4

Injecto-Flo® Piston Distributor System Components 12120

Figure 4 Air Operated Pump

ORDERING INFORMATION

Table 3

RESERVOIR

CAPACITY PART

liters (Pt) MATERIAL NUMBER

2 (4) Plastic 126-400-100

3 (6) Plastic 126-400-120

5 (10) Metal 126-400-130

D

B

F

C

A

Figure 5

1/8 BSP

Air

6mm TUBE

(M12 X 1)

LUBE

OUTLET

E

6.6

(.26)

Replacement Outlet Nut 6mm Tube 435-702-466

Replacement Outlet Ferrule 6mm Tube 435-702-421

Order as separate item (not shown).

3-way, N.C. air solenoid valve 1/8 NPT ports, 115VAC, 60hz

0.11A in-rush, 0.07A holding.

Order Part Number 521-001-024

AIR-OPERATED PUMPS (AO-1)

DESCRIPTION / OPERATION

Operation of the pump is controlled by a remote mounted 3-way

air solenoid valve. Activating this valve allows filtered regulated,

lubricated air to move both the power piston and the lubricant

piston. The resulting lubricant flow pressurizes the system

mainlines causing the piston distributors to dispense a mea-

sured volume of lubricant to the bearing points. De-energizing

the solenoid valve allows air pressure on the power piston to be

exhausted which permits the piston return spring to move both

the power piston and lubricant pistons back to the prime

position. The built in vent valve is simultaneously released

which vents mainline lubricant pressure allowing the piston

distributors to re-prime for the next cycle.

SPECIFICATION

Materials: .............................. Steel and Aluminum Pump,

Nylon, or steel Reservoir.

Output (Max.): .......................... 13cc (0.80in.3) per stroke

Pump Pressure Ratio: .................. (lube out / air in) 4.5:1

Air Pressure: .................................... 4-7 bar (60-100 psi)

Oil Viscosity: ..................... ISO 50-1000 (250-5000 SUS)

Low Level Switch: ......................... 10w @ 115/230 VAC,

5w @ 24 VDC, N.C. Contacts

Off Time Between Cycles (Min.): .................. 15 Seconds

On Time (Min.): ............................................... 5 Seconds

Note: Due to the single stroke operation of this pump, total

System Discharge Volume must not exceed 50% of pump

delivery 6.5cc (0.40in.3).

DIMENSIONS

mm/(inches)

Table 2

RESERVOIR

CAPACITY A B C D E F

2 liters 237.0 186.0 118.0 123.0 148.0 125.0

(4pt) (9.33) (7.32) (4.65) (4.84) (5.83) (4.92)

3 liters 232.0 181.0 126.0 130.0 230.0 160.0

(6pt) (9.13) (7.13) (4.96) (5.12) (9.06) (6.30)

5 liters 232.0 181.0 152.0 236.0 167.0

(10pt) (9.13) (7.13) (5.98) (9.29) (6.57)�

Page 9: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 5

12120Injecto-Flo® Piston Distributor System Components

ELECTRIC MOTOR PUMPS (EO-1)

DESCRIPTION/OPERATION

EO-1 lube packages (Figure 6) consist of a 115 or 230 volt

AC motor direct coupled to a gear pump and mounted on a

steel or plastic reservoir. All are equipped with a low level

switch as standard and are rated for service up to 40 bar

(580 psi) . When electrical power is applied to the pump

motor, lubricant flow pressurizes the system mainlines

causing the piston distributors to dispense a measured

volume of lubricant to the bearing points. De-energizing the

pump stops flow and allows the internal vent valve to release

mainline pressure. This allows the piston distributors to re-

prime in preparation for the next lube cycle. On/off cycles

are achieved using a remote timer that has user selectable

off and on times or control can be via the machine PLC

where available and desired.

SPECIFICATIONS

Motor Voltage: ................. 115 ± 10% VAC, 50/60hz, 1ph

230 ± 10% VAC, 50/60hz, 1ph

Current Consumption:

........................ 4.3 A in-rush, 2.15A running @ 110 VAC

.......................... 1.9 A in-rush, 0.9A running @ 220 VAC

Motor Power: ........................................................ 1/12 hp

Motor Speed: .................................... 1,680 RPM @ 60 hz

1,340 RPM @ 50 hz

Pump Flow Rate: ... 200 cc/Min (12in3/Min.) @ 1680 RPM

Pressure:

........... Relief valve protected 10 - 45 bar (145 - 650 psi)

..................... Relief valve Factory set at 40 bar (580 psi)

Oil Viscosity: ................. ISO 50 - 1500 (250 - 5000 SUS)

Operation: Intermittent, 20% Duty Cycle @ Max. Pressure

(650 psi)

Low Level Switch: ......................... 10w @ 115/230 VAC,

5w @24 VDC, N.C. Contacts

Suction Strainer: ................................... 100 mesh screen

Pressure Gauge: 0 - 60 bar (0-850 psi)

Electrical Connections: Wire terminals in motor junction

box, screw terminals in Low Level Switch connector.

Reservoir Material:

Translucent Plastic: ........................................ Nylon

Metal: ........... Painted steel with guarded glass level tube

Contact Factory for Information on Larger Capacity

Reservoirs and other motor voltages

Replacement Outlet Nut 6mm Tube 435-702-466

Replacement Outlet Ferrule 6mm Tube 435-702-421

ORDERING INFORMATION

Figure 6

RESERVOIRS

PART MOTOR

NUMBER Liters (Gallons) MATERIAL VOLTAGE

126-400-010 3 (.8) Plastic 115V

126-400-020 3 (.8) Plastic 230V

126-400-030 6 (1.6) Plastic 115V

126-400-040 6 (1.6) Plastic 230V

126-400-050 6 (1.6) Metal 115V

126-400-060 6 (1.6) Metal 230V

126-400-070 12 (3.2) Metal 115V

126-400-080 12 (3.2) Metal 230V

Table 4

Page 10: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 6

Injecto-Flo® Piston Distributor System Components 12120

EO-1 INSTALLATION DATA

MountingThe entire lube package is installed with two 6mm (1/4") screws

that pass through holes in the mounting flange at the top of the

reservoir. Mounting dimensions are given in Figure 7 and

Table 5.

Electrical HookupFigure 8 is a simplified schematic for the entire pumping unit. The electrical

hookups are shown in Figures 9a. & 9b. Wiring to the motor and switch

should be with 16 AWG stranded wire and insulation rated for 115/230 VAC

and 1050C.

Figure 9a

FRONT

SIDE

TOP

A

B

6mm TUBE

(M12 X 1)

DISCHARGE

PORT

E

LOW

LEVEL

FILL

CAP

MOUNTING HOLE

CONFIGURATION

6.89

(175

160.0

(6.30)

175.0

(6.89)

U2

C

D

EO-1

Pump

PackageIDEX CORPORATION

U1

PRESSURE

RELIEF

VALVE

M

LOW LEVEL

GAUGE

LUBE

OUTLET

SYSTEM SCHEMATIC

Figure 8

VENT VALVE

Figure 7

RELIEF VALVE

ADJUSTMENT

Table 5 mm/(inches)

LOW LEVEL SWITCH

WIRING SCHEMATIC

COMMON

Figure 9b

NC

Z2

Z1

GND

INPUT POWER

FAN

CAPACITOR

RESERVOIR A B C D E

SIZE MAT'L DIM DIM DIM DIM DIM

3 liters Plastic 324.0 184.0 135.0 185.0 230.0

(.8 gal.) (12.76) (7.25) (5.31) (7.28) (9.06)

6 liters Plastic 419.0 279.0 135.0 185.0 230.0

(1.6 gal.) (16.50) (11.00) (5.31) (7.28) (9.06)

6 liters Metal 418.0 278.0 150.0 185.0 232.0

(1.6 gal.) (16.44) (10.94) (5.91) (7.28) (9.13)

12 liters Metal 418.0 278.0 197.0 209.0 232.0

(3.2 gal.) (16.44) (10.94) (7.76) (8.21) (9.13)

Page 11: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 7

12120Injecto-Flo® Piston Distributor System Components

ELECTRIC MOTOR PUMPS (E0-3)

DESCRIPTION / OPERATION

EO-3 lube packages included a 115 or 230 VAC motor direct

coupled to a gear pump and mounted on a 3 liters�(.8 Gal.)

plastic reservoir. Each is equipped with a low level switch as

standard and is rated for service up to 24 bar (350 psi) .

Timer equipped models include a built in pressure switch.

On/off cycles on remote control models are scheduled by a

remote timer or control can be via the machine PLC where

available and desired. When electrical power is applied to

the pump motor, lubricant flow pressurizes the system

mainlines causing the piston distributors to dispense a

measured volume of lubricant to the bearing points. Making

of the pressure switch contacts (pressure switch equipped

models) or expiration of the on time causes power to be

withdrawn from the motor. This stops flow and permits the

internal vent valve to release mainline pressure which allows

the piston distributors to re-prime in preparation for the next

lube cycle.

SPECIFICATIONS

Motor Voltage: ................ 115 ± 10% VAC, 50/60 hz, 1ph

230 ± 10% VAC, 50/60 hz, 1ph

Current Consumption:

.......................... 3.8 A in-rush, 1.8A running @ 115 VAC

1.9 A in-rush, 0.9A running @ 230 VAC

Motor Power: ........................................................ 1/18 hp

Motor Speed: .................................... 1,680 RPM @ 60 hz

1,340 RPM @ 50 hz

Pump Flow Rate: ........................ 140 cc/min (8.5in3/min.)

Pressure:

........... Relief valve protected 10 - 24 bar (145 - 350 psi)

..................... Relief valve Factory set at 24 bar (350 psi)

Oil Viscosity: ................. ISO 50 - 1500 (250 - 5000 SUS)

Operating Temperature .......................... (-100C to +490C)

(+140F to 1200F)

Operation: Intermittent, 20% Duty Cycle @ Max.

Pressure (350 psi)

*Low Level Switch: ................... 10 watt @ 115/230 VAC,

5w @ 24 VDC, N.C.Contacts

*Motor and Low Level Switch Meet EEC Requirements

(CE Mark Compliance)

Suction Strainer: ..................................... 60 mesh screen

Pressure Gauge: ............................ 0 - 60 bar (0-850 psi)

Electrical Connections: ....Supplied with liquid tight cable

connector and screw terminals.

Reservoir: ...................... 3 liter (.8 gal) Translucent Nylon

Timer Equipped Models only

Timer: ....................................... (On Time) 5-120 Sec.

(Off Time) 2 1/2-160 minutes pre-lube-selectable

Pressure Monitor-Selectable .. 18-22 bar (260-320 psi)

Programming - Via 2 Jumper Bars and 6 dipswitches

One Fault Output ................................................. SPST

Three Indicator Lights ........................... Power on (GN)

Operating (YL), Fault (Rd)

Manual Run ...............................................Push-button

ORDERING INFORMATION

Table 6

Replacement Outlet Nut 6mm Tube 435-702-466

Replacement Outlet Ferrule 6mm Tube 435-702-421

Figure 10

traP

rebmuN

rotoM

egatloV

lortnoC

noitpO

naM

nuR

rotacidnI

sthgiL

erusserP

hctiwS

leveL

hctiwS

510-014-621 V511 etomeR oN oN oN seY

610-014-621 V032 etomeR oN oN oN seY

710-014-621 V511 remiT seY seY seY seY

810-014-621 V032 remiT seY seY seY seY

910-014-621 V511 etomeR oN oN seY seY

120-014-621 V511 etomeR seY oN seY seY

220-014-621 V511 etomeR seY oN oN seY

620-014-621 V022 etomeR oN oN seY seY

Page 12: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 8

Injecto-Flo® Piston Distributor System Components 12120

EO-3 — INSTALLATION DATA

Mounting

The entire lube package is installed with two 6mm (1/4")

screws that pass through holes in the mounting flange at the

top of the reservoir. Mounting dimensions are given in

Figure 11. Figure 12 is a simplified schematic for the entire

pumping unit.

Electrical Hookup

Electrical hookups are shown in Figures 13 and 14. Timer dip

switch settings and jumper bar connections (timer equipped

models) are shown in Figure 15. All electrical connections to

units should be made with 16 AWG stranded wire and

insulation rated for 115/230 VAC and 1050C.

PRESSURE

RELIEF VALVE

M

LOW LEVEL

GAUGE

LUBE

OUTLET

Figure 12 SYSTEM SCHEMATIC

VENT VALVE

DIMENSIONS

mm/(inches)

Figure 11

Figure 13 REMOTE CONTROL

Figure 14 TIME CONTROL

Figure 15

Page 13: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 9

12120Injecto-Flo® Piston Distributor System Components

PISTON DISTRIBUTORS

DESCRIPTION / OPERATIONInjecto-Flo Piston Distributors provide accurate piston

metering of oil directly to a lubrication point. They cover an

output range of .03cc - .60cc (.002 - .037 cu.in.) and are

available as individual distributors (320 and 350 series or as

a unitized distributor manifold (340 series).

Injecto-Flo Piston Distributors are assembled into compact

manifolds having 1 to 10 outlets. While piston distributors

are tamper- resistant, the amount of lubricant delivered to a

given point may be varied by changing the displacement

adapter, or the individual piston distributor.

Manifold inlets and piston distributor outlets are ported for

metric fittings and tubing. Metric to inch size adapters and

fittings are available for users who prefer to use inch size

piping (see fitting section.)

Points may be added to the system by installing additional

manifolds and piston distributors, or removed from the

system by plugging the outlet ports that are no longer

required.

Metering pistons are spring loaded, opposing inlet (main

line) pressure. When inlet pressure (provided by the central

pump) reaches 12 bar (175 psi) or 9 bar (130 psi) for PD340

series, the spring is overcome and the piston is forced into

the discharge chamber, displacing oil taken in at the end of

the previous cycle. When the pump is de-energized, inlet

main line pressure drops, oil bleeds back to tank through the

pump vent valve, and the spring-loaded pistons reset which

primes the discharge chambers for the next lube cycle.

HOW TO ORDER

The Injecto-Flo Piston Distributor System

Manifold Assemblies

Injecto-Flo manifold and piston distributors are assembled at

the factory with the number of stations and displacements as

specified by the user. Assemblies must be shipped with

either working distributors or an outlet plug in every outlet.

Example: PD320 with 3 stations having

outputs of .03, .06 and .16cc.

Order Code: PD-320-3-2-3-5

SPECIFICATION

Pressure:

Minimum to Fire Distributor ................. 12 bar (175 psi)

Maximum ............................................. 60 bar (870 psi)

Oil Viscosity ................. ISO 1000 max. (5000 SUS max.)

Materials:

Manifolds ...................................... Anodized Aluminum

Piston and Valve .................................................. Brass

Seals PD320 & 350 Viton, PD340 .................... Buna-N

Displacement Fitting (340) .................................. Brass

Distributor Body ...................... (320 &350) Plated Steel

Figure 16 Piston Distributors

ORDERING MENU

Part Number Code PDXXX - X - X

SERIES

320

340

350

STATION QUANTITY

PD 320 2,3,5

PD 340 1 Thru 10

PD 350 1,2,3,5

STATION DISPLACEMENT

(SPECIFY IN ORDER LEFT TO RIGHT)

PD320

O OUTLET PLUGGED

2 0.03 CC (.002 CU.IN.)

3 0.06 CC (.004 CU.IN.)

4 0.10 CC (.006 CU.IN.)

5 0.16 CC (.010 CU.IN.)

PD340

O OUTLET PLUGGED

2 0.03 CC (.002 CU.IN.)

3 0.06 CC (.004 CU.IN.)

4 0.10 CC (.006 CU.IN.)

5 0.16 CC (.010 CU.IN.)

PD350

O OUTLET PLUGGED

4 0.10 CC (.006 CU.IN.)

5 0.20 CC (.012 CU.IN.)

6 0.40 CC (.024 CU.IN.)

7 0.60 CC (.037 CU.IN.)

Table 7

PD-320

PD-340PD-350

03 06 16

Page 14: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 10

Injecto-Flo® Piston Distributor System Components 12120

LUBE INLET

6 MM TUBE

(M10x1 )7.11

(.28)

14.99

(.59)

16.5

(.64)

51.0

(2.01)

35.81

(1.41)

15.24

(.60)

PD320 Series

17.0

(.67)

17.0

(.67)

12.0

(.47)

"B"

53.0

(2.09)

14.5

(.57)

8.5

(.33)

LUBE INLET

6 MM TUBE

(M10 X 1)

LUBE OUTLET

4mm TUBE

(M8 X 1)

15.5

(.61)

24.0

(.94) "A"

Figure 17

"B""A"

STATION

DISPLACEMENT

5 STATION MANIFOLD SHOWN

15.5

(.61)17.0

(.67)

LUBE OUTLET

4 MM TUBE

(M8x1)

PD340 Series

PD350 Series

12.0

(.47)

LUBE OUTLET

4mm TUBE

M8 X 1

A

LUBE INLET

(M12 X 1)

11.0

(.43)

12.0

(.47)

80.0

(3.15)

STATIONS DIM. "A" DIM. "B"

1 39.9 (1.57) One Hole

2 47.7 (1.88) One Hole

3 65.0 (2.56) 17.0 (.67)

4 82.0 (3.23) 34.0 (1.34)

5 99.0 (3.90) 51.0 (2.00)

6 116.1 (4.57) 68.6 (2.68)

7 133.1 (5.24) 85.1 (3.35)

8 150.6 (5.93) 102.1 (4.02)

9 167.4 (6.59) 119.1 (4.69)

10 184.2 (7.25) 136.1 (5.36)

Figure 18

Figure 19

STATIONS DIM. "A" DIM. "B"

2 48.0 (1.89) One Hole

3 65.0 (2.56) 17.0 (.67)

5 99.0 (3.90) 51.0 (2.00)

Table 10

Table 9

Table 8

17.0

(.67)

17.0

(.67)17.0

(.67)

17.0

(.67)14.5

(.57)

CContact factory for information on

other supply port configurations

DIMENSIONS mm (inches)

STATIONS DIM. "A" DIM. "B"

1 46.0 (1.81) 23.0 (.91)

2 46.0 (1.81) 23.0 (.91)

3 63.0 (2.48) 31.5 (1.24)

5 97.0 (3.81) 48.5 (1.91)

MOUNTING

SURFACE

MOUNTING

SURFACE

Page 15: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 11

12120Injecto-Flo® Piston Distributor System Components

PISTON DISTRIBUTORS

DISTRIBUTORS, MANIFOLDS AND ACCESSORIES

Dimensions and ordering information for individual piston distributors, displacement adapters and manifolds are shown in figures

19 through 24 and tables 11 and 12. Individual piston distributors and manifolds are not available for the PD340 Series due to

their integral construction, but the displacement adapter may be changed to alter their output to suit a particular application

need.

Station PD320 PD350Quantity Part Number A B Part Number A C

1 - - - 550-151-010 46.0 (1.81) 23.0 (.91)

2 550-151-000 48.0 (1.89) One Hole 550-151-011 46.0 (1.81) 23.0 (.91)

3 550-151-001 65.0 (2.56) 17.0 (.67) 550-151-012 63.0 (2.48) 31.5 (124.0)

5 550-151-002 99.0 (3.90) 51.0 (2.00) 550-151-013 97.0 (3.81) 43.5 (1.91)

Table 12 (Manifolds) DIMENSIONS mm (inches)

PD320 PD350DISPLACEMENT

Adapter

12.0 (.50) HEX

M8 X

1

M10 X

1

37.5

(1.47)

O-RING

6.0

(.24)

Figure 20Figure 22

ORDERING INFORMATION

OUTPUT STAMP (cc)

M8 X

1

58.0

(2.28)

12.0

(.50) HEX12.0

(.50) HEX

6.5

(.26)

Figure 24Figure 23

PD320 PD350

M10 X 1

6mm TUBE

15.5

(.61)17.0

(.67)17.0

(.67)

24.0

(.94)

B

A

M10 X 1

5.0

(.2

0)

19

.5

(.7

7)

4.5

(.18)

17.0

(.67)

17.0

(.67)14.5

(.57)

M12 X 1

6.5

(.26)

7.4

(.2

9)

C

A

M10 X 12

0.0

(.7

9)

25

.0

(.9

9)

Table 11 (Distributors)

PD320 PD340 PD350

Output Piston Displacement Piston

(CC) Distributor Adapter Distributor

.03 550-151-020 551-100-090 -

.06 550-151-021 551-100-080 -

.10 550-151-022 551-100-070 550-151-030

.16 550-151-023 551-100-060 -

.20 - - 550-151-031

.40 - - 550-151-032

.60 - - 550-151-033

O-RING

PD340

Figure 21

† Note: PD320 and PD350 Piston

Distributors share a common

manifold end thread size and may

be intermixed in either the PD320 or

PD350 manifold.

Page 16: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 12

Injecto-Flo® Piston Distributor System Components 12120

ORDERING INFORMATION

Table 13

Part Number Description

422-040-110 O-Ring For M10 X 1 (PD320 & 350)

435-702-261 Distributor Outlet Plug (M8 X 1)

435-702-361 Manifold Plug (M10 X 1)

435-702-403 Manifold Plug (M12 X 1)

435-702-476 Inverted Nut ~ 4 MM Tube (M8 X 1)

435-702-362 Inverted Nut ~6 MM Tube (M10 X 1)

435-702-404 Inverted Nut ~8 MM Tube (M14 X 1.5)

435-380-080 Compression Sleeve ~ 4 MM Tube

435-380-090 Compression Sleeve ~ 6 MM Tube

435-702-405 Compression Sleeve ~ 8 MM Tube

435-702-408 Adapter M10 X 1 to 8mm tube (M14 X 1.5)

435-702-409 Adapter M12 X 1 to 6mm Tube (M10 X 1)

435-702-410 Adapter M12 X 1 to 8mm Tube (M14 X 1.5)

435-702-411 Banjo Elbow M10 X 1 to 6mm Tube (M10 X 1)

435-702-413 Banjo Elbow M12 X 1 to 6mm Tube (M10 X 1)

435-702-414 Banjo Elbow M12 X 1 to 8mm Tube (M14 X 1.5)

435-702-415 Gasket Washer for M8 X 1

435-702-416 Gasket Washer for M10 X 1

435-702-417 Gasket Washer for M12 X 1

435-702-418 Manifold Connector (M10 X 1) (Taper)

435-702-419 Manifold Connector (M12 X 1) (Taper)

435-702-423 Ferule - 4mm Tube

435-702-469 Ferule - 6mm Tube

435-702-472 Outlet Nut - 4mm Tube (M10X1)

435-702-473 Outlet Nut - 6mm Tube (M10X1)

PISTON DISTRIBUTORS

DISTRIBUTOR AND MANIFOLD ACCESSORIES

Note: Refer to fittings and

adapters section for

additional selection.

Figure 25

GASKET

WASHER

Page 17: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 13

12120Injecto-Flo® Piston Distributor System Components

SPECIALTY PISTON DISTRIBUTORS

PD360 PUSH TO CONNECT DISTRIBUTORS

PD360 series piston distributors are supplied with 4mm push

to connect outlets which greatly speed up installation and

piping. They also permit assembly in close quarters where

tightening a threaded connector may not be possible.

Manifolds and inlet fitting used with this series are common

with the PD320 series shown on page 11 and 12.

ORDERING INFORMATION

ORDERING MENU

Part Number Code PD-360 - X - X

STATION QUANTITY (2,3,5)

STATION DISPLACEMENT

(SPECIFY IN ORDER LEFT TO RIGHT)

O OUTLET PLUGGED

2 .025 CC (.002 CU.IN.)

3 .050 CC (.003 CU.IN.)

4 .100 CC (.006 CU.IN.)

5 .150 CC (.009 CU.IN.)

6 .200 CC (.012 CU.IN.)

7 .300 CC (.018 CU.IN.)

OUTPUT

DISTRIBUTOR PART NO. STAMP

0 .025 CC 550-151-090 0

1 .050 CC 550-151-091 1

2 .100 CC 550-151-092 2

3 .150 CC 550-151-093 3

4 .200 CC 550-151-110 4

5 .300 CC 550-151-111 5

MANIFOLD PART NO.

2 STATION 550-151-000

3 STATION 550-151-001

5 STATION 550-151-002

0-RING FOR DISTRIBUTOR

M10 X 1 - 422-040-110

Note: Refer to pages 11 & 12

(PD320) for complete manifold

dimensions and inlet fittings

Figure 26

DIMENSIONS mm/(inches)

4mm

NYLON

TUBE

M10 X 1

6mm

TUBE

75

.7

(2.9

8)

19

.5

(.77)

M10 X

1

A = 2 Station 48.0 (1.89) 3 Station 65.0 (2.56)

5 Station 99.0 (3.90)

O-Ring

56.2

(2.21)6.5

(.26)

12.0 Hex

(.47)

Figure 27

A

PD360

PD370

OUTPUT

STAMP

Page 18: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 14

Injecto-Flo® Piston Distributor System Components 12120

SPECIALTY PISTON DISTRIBUTORS

PD370 BEARING POINT DISTRIBUTOR

PD370 bearing point piston distributors are available as

individual units in straight, 900 or 1800 configurations. They

are mounted at the point of application which means that all

connected lines are on the supply side (mainline) of the

system. This allows monitoring for broken lines via a pump,

or in line mounted pressure switch.

1/8 BSPT OUTLET

FERRULE

15.0

(.59)

NUT

4mm TUBE

6mm TUBE

Figure 30

53.0

(2

.09)

6 &

7

53.0

(2.0

9)

6 &

7

1/8 BSPT

OUTLET

Figure 29

Figure 28

15.0

(.59)

A

13.0 HEX

(.51)

1/8 BSPT

OUTLET

M10 X 1

INLET

FERRULE

NUT

6mm TUBE

4mm TUBE

DIMENSIONS mm/(inches)

Replacement

Displacement Guide Piston Distributor Dim "A"

2 .025 CC (.002 CU.IN.) 550-151-040 30.0 (1.18)

3 .050 CC (.003 CU.IN.) 550-151-041 30.0 (1.18)

4 .100 CC (.006 CU.IN.) 550-151-042 30.0 (1.18)

5 .150 CC (.009 CU.IN.) 550-151-043 30.0 (1.18)

6 .200 CC (.012 CU.IN.) 550-151-050 34.0 (1.34)

7 .300 CC (.018 CU.IN.) 550-151-051 34.0 (1.34)

DESCRIPTION PART NO.

NUT 4mm TUBE 435-702-422

NUT 6mm TUBE 435-702-420

FERRULE 4mm TUBE 435-702-423

FERRULE 6mm TUBE 435-702-469

900 Head 550-151-052

1800 Head 550-151-053

M10 X 1

M10 X 1

INLETM10 X 1

INLET

M10 X 1

NOTE: Order nuts & ferrules as

separate items

49.0

(1

.93)

2 -

5

49.0

(1.9

3)

2 -

5

ORDERING MENU

Part Number Code PD-370 - X - X

CONFIGURATION

1 STRAIGHT

2 900

3 1800

DISPLACEMENT

9.5

(.37)

ORDERING INFORMATION

Page 19: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 15

12120Injecto-Flo® Piston Distributor System Components

SPECIALTY PISTON DISTRIBUTORS

PD380 POST FIRE PISTON DISTRIBUTORS

DESCRIPTION / OPERATION

PD-380 post fire piston distributors are a pressure prime,

spring discharge type making them ideal for applications

such as pallets where the main supply line can only be

connected during a short machining cycle after which the

pallet advances to the next station.

They are available with 1 to 6 outputs covering an output

range of .05cc — .8cc (.003 — .049 cu.in.). Individual

outputs can be changed by replacing the output screw with

one of a different length.

Metering pistons are spring loaded opposing inlet (mainline)

pressure. When inlet pressure (provided by the central

pump) reaches 16 bar (232 psi), the spring is overcome and

the metering piston is forced against its stop (output screw)

by the inlet side oil pressure,. When main line pressure is

vented at the pump, the metering piston is advanced to its

rest position by the expanding return spring and a measured

shot of oil is directed out of the outlet.

SPECIFICATIONS

Pressure:

Minimum to Fire ............................... 16 bar (232 psi)

Maximum........................................... 40 bar 580 psi)

Oil Viscosity ISO 1000 ............................ (5000 sus) max

Materials:

Body .......................................................Plated Steel

Seals ................................................................. Viton

Output Scew ..........................................Plated Steel

ORDERING MENU

Part Number Code PD-380 - X - X

Station Quantity (1-6)

Station Displacement

(Specify in Order Left to Right)

0 No Output

3 .05cc (.003 cu.in.)

4 .10cc (.006 cu.in.)

5 .20cc (.012 cu.in.)

6 .30cc (.018 cu.in.)

7 .40cc (.024 cu.in.)

8 .60cc (.037 cu.in.)

9 .80cc (.049 cu.in.)

ORDERING INFORMATION

Manifold Assembly Part Number

(Less Output Screw)

STATIONS PART NO.

1 550-155-0002 550-155-001

3 550-155-002

4 550-155-003

5 550-155-004

6 550-155-005

OUTPUT

MARKING CC (CU.IN.) PART NO.

05 .05 (.003) 435-702-478

1 .10 (.006) 435-702-479

2 .20 (.012) 435-702-480

3 .30 (.018) 435-702-481

4 .40 (.024) 435-702-482

6 .60 (.037) 435-702-483

8 .80 (.049) 435-702-484

x No Output 435-702-486

Output Screw

Figure 31

Page 20: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 16

Injecto-Flo® Piston Distributor System Components 12120

OUTPUT

MARKING CC (CU.IN.) L

X NO OUTPUT 24.0

05 0.05 (.003) 23.65

1 0.10 (.006) 23.2

2 0.20 (.012) 22.3

3 0.30 (.018) 21.4

4 0.40 (.024) 20.5

6 0.60 (.037) 18.8

8 0.80 (.049) 17.2

Figure 32

Figure 33

Output Screw

Part Number Description

435-702-403 Mainfold Plug (M12 X 1)

435-702-362 Inverted Nut - 6 mm Tube (M10 x 1)

435-702-404 Inverted Nut - 8 mm Tube (M14 x 1.5)

435-702-000 Compression Sleeve - 6 mm Tube

435-702-405 Compression Sleeve - 8 mm Tube

435-702-409 Adapter M12 X 1 to 6 mm Tube (M10 X 1)

435-702-410 Adapter M12 X 1 to 8 mm Tube (M14 x 1.5)

435-702-413 Banjo Elbow M12 X 1 to 6 mm Tube (M10 X 1)

435-702-414 Banjo Elbow M12 X 1 to 8 mm Tube (M14 X 1.5)

435-702-417 Gasket Washer for M12 X 1

435-702-419 Manifold Connector (M12 X 1)

435-702-423 Ferule - 4 mm Tube

435-702-469 Ferule - 6 mm Tube

435-702-472 Outlet Nut - 4 mm Tube (M10 X 1)

435-702-473 Outlet Nut - 6 mm Tube (M10 X 1)

NOTE: Refer to fittings and adapter section

for additional selection.

PD-380 ACCESSORIES / ORDERING INFORMATION

ACCESSORIES

OUTLETS A B

1 24 (.94) 36 (1.42)

2 41 (1.61) 53 (2.09)

3 58 (2.28) 70 (2.76)

4 75 (2.95) 87 (3.43)

5 92 (3.62) 104 (4.09)

6 109 (4.29) 121 (4.76)

Figure 34

DIMENSIONS mm (Inches)

Manifold

Plug

Manifold

Connector Gasket

Washer

Page 21: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 17

12120Injecto-Flo® Piston Distributor System Components

R

IDEX CORPORATION

ELECTRICAL CONTROLS

Solid-State A-C Timer

DESCRIPTION / OPERATION

The Solid-State Timer from Lubriquip operates on stan-

dard 115/230 VAC 50/60 hz input power, and provides a

total on and off cycle with “on” periods to meet your

specific lubrication system’s requirements. Total cycle

times can be set from 30 seconds to 32 hours. “On” time

during the total cycle time can be set from 12 seconds to

13 minutes. The “on” time occurs at the beginning of each

period.

The Solid-State Timer operates on common 115/230 VAC

50/60 hz input power. Output is also 115/230 VAC 50/60

hz, which is directed to power the pump, or to trigger a

solenoid that activates a pneumatic pump. User sets

desired total cycle time and “on” time. The timer will

provide output power for as long as the time set on the

“on” cycle. Manual run circuit resets timer to the beginning

of a total cycle.

SPECIFICATIONS

Electrical .......... 1ph,115/230 VAC 50/60 hz 5 AMP (Max)

Temperature Range:

Operating .................................. -180 to 550C (00 to1310F)

Storage ................................ -550 to 850 C(-670 to 1850 F)

Enclosure .......................................... High Impact Plastic

Component Technology ...................... Solid-State CMOS

Cycle Frequency, Adjustable:

Range 1 ............................................... 0.5 to 30 minutes

Range 2 ................................................... 0.5 to 32 hours

“On” time .............................................. 0.2 to 13 minutes

Vibration ........................................................... 5g’s 50 hz

HOW TO ORDER

DESCRIPTION PART NO.

Solid-State Timer .............................................. 163-400-000

Replacement Board ..........................................572-142-590

Input Fuse AGC 1/2 Amp .................................. 572-101-000

Load Fuse ABC 5 Amp, Fast-Blow ...................492-240-130

DIMENSIONS mm/(inches)

Figure 36

Figure 35

NOTE: Two spare terminals are provided for customer

convenience. They are not connected on the board and can

be used for any terminations or junctions.

Figure 37

Figure 38

Page 22: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 18

Injecto-Flo® Piston Distributor System Components 12120

ELECTRICAL CONTROLS

SC-Solid State Stroke Counter

DESCRIPTION / OPERATION

The Trabon Stroke Counter programs the operation of a

lubrication system using machine cycles or strokes rather

than time. It energizes a load that initiates the lubrication

system each time the machine cycles through the number of

strokes preset on the stroke setting dial. It is a low cost

control especially suited to equipment which operates on a

variable duty cycle.

Set the Stroke Counter to provide the amount of lubrication

required by the operating equipment using the Stroke Setting

switch. This is a ten-position switch which covers the range

of 32 to 320 machine strokes in 32 stroke increments. It is

the only adjustment needed.

When the equipment is started the pre-lube feature automati-

cally energizes the load for five seconds causing lubricant to

be pumped. At the end of this time, the Stroke Counter

begins counting cycles through an external stroke switch

actuated by the operating machine. When the counter

reaches the number of strokes preset on the selector switch

it energizes the load. During the five second lubricating time,

the counter resets to zero. It begins counting strokes again

after the load is de-energized.

Pressing the Manual Run push-button or selecting a different

stroke setting actuates the pre-lube feature and resets the

counter to zero.

If power is interrupted, the accumulated stroke count is lost.

Restoration of power automatically actuates the pre-lube

feature and resets the counter to zero.

SPECIFICATIONS

Power Supply ......Single phase, 115±10% VAC 50/60 hz

Current Consumption .............. Less than .1 amp (without

external load)

External Load ............. 1 amp max. at 115 VAC, 50/60 hz

Ambient Temperature Range ..................... -180C to 500C

(00F to 1220F)

Enclosure ...........................................High impact plastic

Programming Stroke Range ................ 32 to 320 strokes

(32 stroke increments)

Load On-Time ....................................... 5 seconds ±20%

Max. Count Rate ............. 5 strokes/sec., 50% duty cycle

Stroke Switch (supplied by customer) ................ switches

12 VDC at 1.2 ma. (Note: 115 VAC potential exists on

the switch terminals [1 to 3)

Pre-Lube ............. Energizes load when power is applied

Net Weight ....................................... .567 kg (1 lb. 4 oz.),ORDERING INFORMATION

SC-Stroke Counter Part No. ........................ 163-210-050

Figure 39

DIMENSIONS mm/(inches)

Figure 40

Figure 41

WIRING DIAGRAM

Page 23: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 19

12120Injecto-Flo® Piston Distributor System Components

ELECTRICAL CONTROLS

TC1000 SOLID STATE TIMER/

COUNTER:

The TC1000 Solid State Timer/Counter is a microprocessor based

multi-use controller dedicated to the operation of centralized

lubrication systems.

The TC1000 schedules lube frequency either on a time or stroke/

cycle basis in values ranging from 1-9999. The pump run interval is

also selectable in time or counts over the same range. Note that the

circuit should only be programmed for time (5-15 seconds) when

used with a piston distributor system.

The TC1000 is easily programmed in the field through four mini

pushbuttons. No special training or knowledge of computer lan-

guage is necessary. During power down or outage, data is saved in

EEProm (Electrically Erasable Programmable Read Only Memory).

When power is restored, counting and pump status is restored to

values prior to loss of power.

Available for 115 VAC, 230 VAC, 12 VDC, or 24 VDC operation.

Pump Output voltage is the same as supply voltage.

SPECIFICATION

Power Supply:

115 VAC ± 15%, 50 or 60 hz, 1ph

230 VAC ± 15%, 50 or 60 hz, 1ph

12 VDC ± 15%

24 VDC ± 15 %

Output Voltage (Same as Supply)

10 A Relay Output (External Fused by User)

Temperature Range:

Operating ............................. -200C to 500C (-40F to 1220F)

Storage .............................. -250C to 600C (-130F to 1400F )

Enclosure:

High Impact Plastic

Programming Selection:

Hours, Minutes, Seconds, Counts

On Time: ................ 1 to 9999 (Program for 5 -15 seconds)

Off Time: .............................................................. 1 to 9999

Stroke / Cycle Input:

24 Volts

Selectable for either Source or Sink

Solid State Proximity Switch or Dry Contact

Display:

Supertwist LCD

Annotated 4 Digit

Program Entry:

4 Mini Push Buttons - Program, Increase, Shift, Enter

Manual Run:

Push Button

Figure 42

DIMENSIONS

mm/(inches)

ORDERING INFORMATION

VOLTAGE PART NUMBER

115 VAC, 50/60hz 163-400-042

230 VAC, 50/60hz 163-400-043

12 VDC 163-400-040

24 VDC 163-400-041

R

IDEX CORPORATION

Figure 43

Page 24: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 20

Injecto-Flo® Piston Distributor System Components 12120

Figure 44

The Trabon microprocessor based LC-1000 Controller is a multi-

use solid state controller that is dedicated to the operation and

monitoring of centralized lubrication systems.

The LC-1000 monitors and schedules lubrication intervals in

either time or stroke/cycle basis in values ranging from 1 to 9999.

The pump run duration is selectable in counts time or by

pressure switch closure.

Four units are available for 12 VDC, 24 VDC, 115 VAC, or 230

VAC operation. The LC-1000 is easy to program in the field

using four mini push-button. The programming requires no

special knowledge or training of computer language. During

power down or outage, all data is saved in EEPROM (Electrically

Erasable Programming Read Only Memory). As power is

restored, counting and pump status are restored to values prior to

the loss of power.

SPECIFICATIONS

Power Supply

115 VAC + 10%, 50/60 Hz, 1 ph

230 VAC + 10%, 50/60 Hz, 1 ph

12 VDC + 10%

24 VDC + 10%

Output Loading

Main Pump Load: .................... 32 VDC – 230 VAC, 50/60 Hz

10 Amp Relay Output (External Fused by User)

Fault Output Signal: ................ 32 VDC – 230 VAC, 50/60 Hz

1 Amp Resistive Max. Dry Isolated Contact (External Fused by

User)

Temperature Range

Operating: ..................................... -20C to 50C (-4F to 122F)

Storage: ...................................... -25C to 60C (-13F to 140F)

Enclosure

Plastic with Clear Cover, NEMA 12/13, IP 54

Display

Supertwist LCD

Annotated 4 Digit

4 LED’s: PWR (GN), LUBE (YW), FAULT (RD), CYCLE (YW)

Stroke Input

Nominal 12 Volts for 12 VDC Version

Nominal 24 Volts for 24 VDC, 115 VAC, 230 VAC Versions

Selectable for either Source or Sink

Solid State Proximity Switch or Dry Contact

10 mA Max.

Other Inputs

Cycle Switch: ................... 5 Volts, Dry Contact, 2.5 mA Max.

Counts Half Cycles

DIMENSIONS Inches/(mm)

Programming Selection

Output ON or Monitor Interval:

......................... 1 to 9999 Seconds, Minutes, Hours, Counts

Output OFF: ..... 1 to 9999 Seconds, Minutes, Hours, Counts

Cycle Counter: ...................................... Half Counts (0 to 99)

Pump: ................................................ Steady State or Pulsed

Pulse Off Time (Relief) – 3 Seconds Fixed

Pulse On Programmable - 0 to 99 Seconds

Note: Pulsed output is not used with Piston Distributor

Systems

Program Entry

4 Mini Push Buttons – Program, Increase, Shift, Enter

EEPROM

Electrically Erasable Programming Read Only Memory

127.0

(5.00)

4.8 (.19)

114.3(4.50)

127.0

(5.00)

11

4.3

(4.5

0)

76.2

(3.00)Figure 45

Page 25: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 21

12120Injecto-Flo® Piston Distributor System Components

PROGRAMMING INSTRUCTIONS

DISPLAYS:The LC-1000 Controller has icons in the display to indicate if

the unit is in a lube ON cycle or OFF cycle and to show the

timing mode. They are also used to indicate which counter

is being adjusted when programming new parameters. The

LCD four digit display is used to show the remaining time left

in either an on or off cycle, as indicated by the icons. Timing

can be done in seconds, minutes, hours or counts. A

flashing LCD character indicates that the timer is in the

Programming mode.

PUSH BUTTONS:There are four push buttons;

PRGM - Program, alternate between setting OFF, ON

(Monitor), Cycle Count, or Pump Duty Cycle (Pulsed

Pump On)

- Increase digit

- Next digit select

ENT - Enter (save) new setting

OPERATION:When power is applied, the timer counts down alternately

from the programmed ON/OFF times to zero. In the ON

TIME mode, the RUN is activated and the ON icon lights.

The digital display counts down the remaining time/counts in

the monitor interval. If the display reaches 0000 before the

pressure switch closes (cycle count). A fault will be regis-

tered indicating that system main line pressure was not

sufficient for reliable Piston Distributor operation. If the

pressure switch closes before expiration of the monitor (ON)

interval, the LC-1000 reverts to the OFF interval and the

display counts down to the next lube period.

The Controller is programmed to retain in memory the timecount when power is turned off. This feature preventsoverlube in start/stop applications and retains information forcycle to be completed when power is returned.

VOLTAGE PART NUMBER

12 VDC 163-400-050

24 VDC 163-400-051

115 VAC, 50/60 hz 163-400-052

230 VAC, 50/60 hz 163-400-053

ORDERING INFORMATION

WIRING INFORMATION

CHANGING SETTINGS:From the Timer display mode, pressing the Program button

will allow you to review or change between the SET ON, SET

OFF, CYCLE, PUMP DUTY CYCLE and DISPLAY modes.

When the program is pressed the first time, the ON icon will

start to blink indicating the change mode. Pressing the

PRGM again will light the OFF icon and display the existing

OFF time. Pressing PRGM a third time will light the CYCLE

icon. Pressing PRGM a fourth time will light the PUMP icon.

Pressing the PRGM a fifth time will return the unit back to the

DISPLAY mode, showing the current status of the timer. No

icons or digits will be blinking in the DISPLAY mode.

To set a new monitor interval ("ON" time). Press the "PRGM"

key until the "ON" icon begins to blink. The existing ON time/

count will be displayed. Press the "ENT" key. The ON time/

count value will blink. Using the key and key set the

monitor ("ON") value between 10 and 20. Press "ENT" to

register the new value. The SEC/MIN/HR/CNT icon will now

blink. Press the key to scroll through the timing choices

and select "SEC". Press "ENT" to register the new time

base. The "OFF" icon will now be blinking. Press "ENT", the

existing OFF time/count value will blink. Using the key and

key set the desired OFF time/count (idle period). Press

"ENT" to register the new value. The SEC/MIN/HR/CNT icon

will now blink. Press the key to scroll through the timing

choices and select the desired unit. Press "ENT" to register

the new time base. The "CYCLE" icon will now be blinking.

Press "ENT" and the CYCLE VALUE will blink. Use the

key and key to select 01. Press "ENT" to register the new

value. The "PUMP" icon will now be blinking. Press "ENT"

and the "PUMP" (pulsed on time) will blink. This feature is

not used with Piston Distributors. Use key and key to

select 00. Press "ENT" to register the value and return to the

DISPLAY mode. Programming is now completed.

Note: Scrolling through the modes using the PRGM key only

will allow the review of the current settings without changing

any of the values or timing. Exiting after changing a value

will initiate a Manual Run as the new values will take effect.

MANUAL RUN:A manual run cycle may be initiated from the normal Display

Mode by pressing the manual run push button, or both the

and the ENT buttons together. After changing the timer

settings, a manual run initiated will make the new values

active and reset a fault momentarily, closing contacts 5 and 6

will also initiate a manual run.

Figure 46

Page 26: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 22

Injecto-Flo® Piston Distributor System Components 12120

ACCESSORIES

Pressure Gauges

PRESSURE SWITCHES (N.O.)

SPECIFICATIONS

Max. Pressure: .................................... 200 bar (2900 psi)

Voltage: ....................................... 220 Max., 100 VA Max.

Current (Max.): ........................... 0.5A Resist., 0.25A Ind.

SPECIFICATIONS

Material: ..... Plated Steel Body Sintered Bronze Element

Filter Rating (Nominal) ..................................... 25 Micron

Max. Pressure: .................................... 200 bar (2900 psi)

Order Part Number .......................................473-000-232

Replacement Element ..................................473-000-231

Range, Thread Dimensions - mm/(inches) Order

bar (psi) Fig. T A B C Part No.

0-60 1/8 40.0 24.0 35.6

(0-850) 42 BSPT (1.57) (.95) (1.40) 126-410-011

0-70 1/4 55.6 26.9 41.3

(0-1000) 42 NPTF (2.19) (1.06) (1.62) 534-335-000

0-70 1/4 55.6 68.3

(0-1000) 43 NPTF (2.19) (2.69) - 493-020-198

Figure 48

SPECIFICATIONS

Material: ................................ Aluminum Body, S.S. Filter

Screen, Buna-N Seal

Sieve Size: .......... 200 x 1400 mesh (10 micron nominal)

120 x 600 mesh (28 micron nominal)

Max. Pressure: .................................... 200 bar (2900 psi)

ORDERING INFORMATION

Thread Micron Part Number

1/4 BSPT 10 527-101-150

1/4 BSPT 28 527-101-160

Figure 47

Figure 49

Figure 50

Figure 52

Figure 51

Adjustment Screw

24 HEX

(.94)

ORDERING INFORMATION

ADJ Range Part Number

bar (psi) Switch Cap

10-20 (145-290) 493-120-040 493-120-050

20-50 (290-725) 493-120-045 493-120-050

1/8

BSPT

FILTERS

Page 27: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 23

12120Injecto-Flo® Piston Distributor System Components

ACCESSORIES - ANCHOR FITTINGS

DESCRIPTION

Anchor fittings are designed for simplicity of use and long

life. They provide a solid base for mounting pressure gauges

and pressure switches...for connecting hoses to lube

lines...for attaching lines to machines or equipment... for

adding branch lines or facilitating abrupt changes in line

direction.

Straight Anchor Block (Aluminum)

Thread Order

T Part Number

M8X1 509-200-000

M10X1 509-201-000

M14X1.5 509-204-000

1/8 BSP 509-202-000

1/8 NPSF 509-170-000

1/4 BSP 509-205-000

Thread Order

T Part Number

M8X1 509-220-000

M10X1 509-221-000

M14X1.5 509-222-020

1/8 BSP 509-222-000

1/8 NPSF 509-189-000

1/4 BSP 509-225-000

900 Angle Anchor Fitting

(Zinc-plated steel)

Anchor Tee (Zinc Plated Steel)

Anchor Cross 4-Way

(Zinc Plated Steel)

Figure 54

OrderA B Part Number

M8X1 (4mm Tube) 1/8 NPSF 482-000-348

M8X1 (4mm Tube) M8X1 482-000-463

M10X1 (6mm Tube) M10X1 482-000-464

1/8 BSPT 1/8 BSPT 509-222-010

1/4 BSPT 1/4 BSPT 509-222-015

Figure 53

Figure 56

Figure 55

Thread Order

T Part Number

M8X1 509-210-000

M10X1 509-211-000

1/8 BSP 509-212-000

1/8 NPSF 509-213-000

M14X1.5 509-214-000

1/4 BSP 509-215-000

Page 28: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 24

Injecto-Flo® Piston Distributor System Components 12120

ACCESSORIES - MULTI-PORT MANIFOLDS

Single Side Manifold

Double Side Manifold

Figure 58

Figure 57

traP

rebmuN

fo.oN

steltuO

A

miD

B

miD

071-151-055 1 )2.1(13 )7.0(02

171-151-055 2 )0.2(25 )6.1(14

271-151-055 3 )8.2(37 )4.2(26

371-151-055 4 )7.3(49 )2.3(38

471-151-055 5 )5.4(511 )2.3(401

571-151-055 6 )3.5(631 )9.4(521

671-151-055 7 )1.6(751 )7.5(641

771-151-055 8 )0.7(871 )5.6(761

871-151-055 9 )8.7(991 )4.7(881

971-151-055 01 )6.8(022 )2.8(902

traP

rebmuN

fo.oN

steltuO

A

miD

B

miD

081-151-055 2 )2.1(13 )7.0(02

181-151-055 4 )0.2(25 )6.1(14

281-151-055 6 )8.2(37 )4.2(26

381-151-055 8 )7.3(49 )2.3(38

481-151-055 01 )5.4(511 )2.3(401

581-151-055 21 )3.5(631 )9.4(521

681-151-055 41 )1.6(751 )7.5(641

Page 29: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 25

12120Injecto-Flo® Piston Distributor System Components

ACCESSORIES - ADAPTERS AND TUBE FITTINGS

(Nuts, Sleeves, Ferules and Gasket Washers must be ordered separtely)

Manifold Adapter - Straight

Manifold Adapter -

Banjo Elbow

Manifold Connector

Pump and Manifold Lube Outlet

Nut and Ferrule

PD370 Lube Supply

Nut and Ferrule

Manifold Gasket

Plug Washer

Distributor Outlet Plug

Thread Thread Tube Order

A B Size Part Number

M10 X 1 M14 X 1.5 8mm 435-702-408

M12 X 1 M10 X 1 6mm 435-702-409

M12 X 1 M14 X 1.5 8mm 435-702-410

M12 X 1 1/4 NPTF — 435-702-471

Thread Thread Tube Order

A B Size Part Number

M6 X 1 M8 X 1 4mm 435-702-465

M10 X 1 M10 X 1 6mm 435-702-411

M12 X 1 M10 X 1 6mm 435-702-413

M12 X 1 M14 X 1.5 8mm 435-702-414

Order Part Number 435-702-267

Tube Order Part Numbers

Size Nut Ferrule

4mm 435-702-422 435-702-423

6mm 435-702-420 435-702-469

Thread Order

T Part Number

M10 X 1 435-702-418

M12 X 1 435-702-419

Thread Order

A Part Number

M10 X 1 435-702-361

M12 X 1 435-702-403

Thread Order

REF Part Number

M10 X 1 435-702-416

M12 X 1 435-702-417

Tube Order Part Number

Size Thread Nut Ferrule

4mm M10 X 1 435-702-472 435-702-423

6mm M10 X 1 435-702-473 435-702-469

6mm M12 X 1 435-702-466 435-702-421

SEE FIG. 62

Page 30: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 26

Injecto-Flo® Piston Distributor System Components 12120

Male Connector

450 Male Elbow

Male Elbow

900 Street Elbow

450 Street Elbow

Inverted Nut and Compression Sleeve

ACCESSORIES - ADAPTERS AND TUBE FITTINGS

(Nuts, Sleeves, Ferules and Gasket Washers must be ordered separtely)

Tube Thread Thread Order

Size A B Part Number

4mm 5/16 - 24 1/8 BSPT 435-702-424

4mm 5/16 - 24 1/4 BSPT 435-702-425

6mm 1/8 BSPP 1/8 BSPT 435-702-426

6mm 1/8 BSPP 1/4 BSPT 435-702-427

Thread Thread Order

A B Part Number

1/8 BSP 1/8 BSP 435-702-439

1/4 BSP 1/4 BSP 435-702-440

1/8 NPT 1/8 NPT 509-111-000

1/4 NPT 1/4 NPT 509-114-000

Thread Thread Order

A B Part Number

1/8 BSP 1/8 BSP 435-702-436

1/8 BSP 1/4 BSP 435-702-437

1/4 NPT 1/4 BSP 435-702-438

1/8 NPT 1/8 NPT 509-110-000

1/8 NPT 1/4 NPT 509-112-000

1/4 NPT 1/4 NPT 509-113-000

Tube Thread Thread Order

Size A B Part Number

4mm 5/16 - 24 1/8 BSPT 435-702-428

6mm 1/8 BSPP 1/8 BSPT 435-702-430

Tube Thread Thread Order

Size A B Part Number

4mm 5/16 - 24 1/8 BSPT 435-702-432

4mm 5/16 - 24 1/4 BSPT 435-702-433

6mm 1/8 BSPP 1/8 BSPT 435-702-434

6mm 1/8 BSPP 1/4 BSPT 435-702-435

Tube Thread Order Part Numbers

Size T Nut Sleeve

4mm M8 X 1 435-702-476 435-380-080

092914

6mm M10 X 1 435-702-362 435-380-090

8mm M14 X 1.5 435-702-404 435-702-405

4mm 5/16 - 24 435-702-474 435-380-080

092914

6mm 1/8 BSPP 435-702-475 435-380-090

*

*

* Single Bevel Sleeve

Page 31: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 27

12120Injecto-Flo® Piston Distributor System Components

ACCESSORIES - PUSH TO CONNECT TUBE FITTINGS

DESCRIPTION

For use with nylon or soft metal tubing (no tools required).

Simply push tubing in until it bottoms (saves 75% of assem-

bly time). Can be disassembled by holding down insert and

withdrawing tube.

SPECIFICATIONS

Material ................................................................... Brass

Seal: ..................................................................... Buna-N

Thread Sealant: ......................... Teflon® (factory applied)

Working Pressure (max.) ........................ 52 bar (750 psi)

Male Connector

Figure 73

Note: Internal Hex ("D" Dimension) can be used for tighten-

ing with Allen key.

Male Elbow

Swivel Male Elbow

Figure 75

Tube DIMENSIONS - mm (inches) Order

O.D. A B C Part Number

4mm 33.4 (1.31) 27.0 (1.06) 11.0 (.43) 435-702-457

6mm 42.0 (1.65) 35.0 (1.38) 11.0 (.43) 435-702-458

8mm 45.0 (1.77) 38.0 (1.50) 14.0 (.55) 435-702-459

Figure 74

Figure 76

Union

Tube Pipe DIMENSIONS - mm /(inches) Order

O.D. Thread A B C D Part Number

4mm 1/8 BSPT 19.2 (.76) 16.0 (.63) 11.0 (.43) 26.7 (1.05) 435-702-393

4mm 1/4 BSPT 19.2 (.76) 16.0 (.63) 14.0 (.55) 31.7 (1.25) 435-702-451

6mm 1/8 BSPT 26.0 (1.02) 22.5 (.89) 11.0 (.43) 28.7 (1.13) 435-702-452

6mm 1/4 BSPT 26.0 (1.02) 22.5 (.89) 14.0 (.55) 33.7 (1.33) 435-702-453

8mm 1/4 NPTF 27.0 (1.06) 23.5 (.93) 14.0 (.55) 35.2 (1.39) 435-702-454

4mm 1/8 NPTF 20.2 (.80) 17.0 (.67) 11.1 (.43) 26.7 (1.05) 435-702-391

4mm 1/4 NPTF 20.2 (.80) 17.0 (.67) 14.3 (.56) 31.7 (1.25) 435-702-456

Union Elbow

Figure 77

DIMENSIONS -

Tube mm (inches) Order

O.D. A B Part Number

6mm 26.0 (1.02) 22.5 (.89) 435-702-460

8mm 27.0 (1.06) 23.5 (.93) 435-702-461

Tube Pipe DIMENSIONS - mm (inches) Order

O.D. Thread A B C D Part Number

4 mm 1/8 BSPT 19.3 (.76) 16.1 (.63) 11.0 (.43) 3.2 (.13) 435-702-392

4mm 1/4 BSPT 22.5 (.89) 19.3 (.76) 14.0 (.55) 3.2 (.13) 435-702-441

6mm 1/4 BSPT 23.8 (.94) 20.3 (.80) 14.0 (.55) 4.8 (.19) 435-702-442

8mm 1/4 BSPT 31.3 (1.23) 27.8 (1.09) 14.0 (.55) 4.8 (.19) 435-702-443

4mm 1/8 NPTF 20.2 (.80) 17.0 (.67) 11.0 (.43) 3.2 (.13) 435-702-390

4mm 1/4 NPTF 24.7 (.97) 21.5 (.85) 14.3 (.56) 4.8 (.19) 435-702-444

Tube Pipe DIMENSIONS - mm (inches) Order

O.D. Thread A B C D Part Number

4mm 1/8 BSPT 22.2 (.87) 19.0 (.75 8.0 (.31) 17.6 (.69) 435-702-445

6mm 1/8 BSPT 26.2 (1.03) 22.7 (.89) 9.0 (.35) 18.6 (.73) 435-702-447

6mm 1/4 BSPT 26.2 (1.03) 22.7 (.89) 11.0 (.43) 23.3 (.92) 435-702-448

8mm 1/4 NPTF 27.0 (1.06) 23.5 (.93) 11.0 (.43) 23.3 (.92) 435-702-449

4mm 1/8 NPTF 22.0 (.87) 19.0 (.75) 8.0 (.31) 17.6 (.69) 435-702-395

4mm 1/4 NPTF 20.2 (.80) 17.0 (.67) 8.0 (.31) 23.8 (.94) 435-702-450

Page 32: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 28

Injecto-Flo® Piston Distributor System Components 12120

ACCESSORIES - PUSH TO CONNECT TUBE FITTINGS

Figure 78

Tube DIMENSIONS - mm (inches) Order

O.D. A B C Part Number

4mm 20.2 (.80) 17.0 (.67) 8.0 (3.1) 435-702-462

6mm 26.2 (1.03) 22.7 (.89) 9.0 (.35) 435-702-463

8mm 28.0 (1.10) 24.5 (.96) 11.0 (.43) 435-702-464

Flexible Nylon Tubing

NOTE:

1. Tubing supplied in 7.6m coils (25ft)

2. Stated burst pressure is at 230C (730F). Burst pressure

decrease as temperature increases to approx. 50% @

930C (2000F).

Figure 79

Tube Tube Burst Pressure Min Bend Order

O.D. ID (mm) (bar) (psi) Radius Part Number

4mm 2.7 100 1450 28 (1.10) 400-132-065

6mm 4.0 100 1450 35 (1.38) 400-132-025

8mm 6.0 76 1102 55 (2.17) 400-132-070

Tube Support Insert

Tube, Tube Clips and Hose Assemblies

Union Tee Tube Clips

Hose Assemblies

Tube A Order

O.D. mm/(inches) Part Number

4mm 2.5 (.100) 435-520-080

6mm 3.8 (.150) 435-520-090

8mm 5.8 (.228) 435-520-100

Figure 80

NOTE: Tube support inserts are installed in the tube I.D.

when assembling compression fittings to nylon tubing in

order to minimize tube collapse.

Tube Order Part Number

Size 1 Tube 2 Tube 3 Tube 4 Tube

4mm 435-710-010 435-710-020 435-710-030 435-710-040

6mm 500-981-000 500-982-000 500-983-000 500-984-000

8mm 435-270-030

Figure 81

SPECIFICATIONS

Intertube: ................................................................. Nylon

Cover: ...................................................................... Nylon

Reinforcement: ............................................. 1 Fiber braid

Size: .............................................................. 4mm, 6 mm

Working Pressure: .............................. 476 bar (6900 psi)

Min. Bend Radius: ................................................ 19 (.75)

Tube Order

O.D. (mm) (inches Part Number

4mm 450 17.7 443-700-030

4mm 600 23.6 443-700-031

4mm 750 29.5 443-700-032

6mm 450 17.7 443-700-033

6mm 650 22.6 443-700-034

6mm 750 29.5 443-700-035

Figure 82

Page 33: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 29

12120Injecto-Flo® Piston Distributor System Components

Lubriquip systems are available for every type of industrial mechanical equipment. Some find wide application while

others are highly specialized. For specific recommendations, see your Lubriquip Distributor, or call 1-800 USA LUBE.

L U B R I Q U I P S Y S T E M S

SYSTEM\ INDUSTRIES\ AVAILABLE METERING SYSTEM ADVANTAGES\ SEE

LUBRICANT APPLICATIONS PUMP DRIVES TYPE & OPERATION FEATURES BENEFITS BULLETIN

Trabon Series All types of equipment Electric Series progressive Positive displacement piston Interconnections allow 10102

oil or grease and machines Hydraulic network, flow valves; stackable and inexpensive monitoring 10132

E-Z Luber, Pneumatic actuated divider subplate mounted; of each lube point; 12000

grease only. Mechanical valve all valve sections inter- tamper proof displacement 12605

Manual connect hydraulically volume 12715

Bi-Flo Long production lines; Electric, manual, Dual line, parallel, Positive displacement Relatively easy to add and 20107

rolling mills, automotive pneumatic. pressure-actuated piston valves; adjustable delete lube points; system

transfer lines, etc. feeders. output; dual header lines layout usually not affected

alternately pressurized. by line length.

LubriSystem, Medium and smaller Electric Single line parallel, Positive displacement; Relatively low cost com- 12100

Oil, fluid grease size machines; plastic Pneumatic pressure-actuated, adjustable output; ponents; easy to design 12120

Injecto-Flo and rubber molding, Manual spring-reset LubriSystem available and modify system;

Piston Distributor food packaging, injectors & Piston in stainless steel. aluminum injectors and

Oil only. printing etc. Distributors. manifolds have low weight

Trif-T Luber Smaller machines Electric Single line parallel, Resistive orifice metering Lowest cost terminating TL-400

Oil only Manual orifice metering valves with fixed output; lube system available;

orifice can be built into individual orifice meters can

equipment usually be installed at lube

point.

Grease Jockey Mobile and mining Electric Single line parallel, Manifold mounted injector Simplified, low-cost installation GJ-10050

E-Z Luber equipment, off-road Pneumatic pressure-actuated modules engineered for of modules; designed for a GJ-10060

heavy machinery, over Manual spring-reset mobile equipment rugged environment.

the-road tractor trucks injectors

TrackMaster Railroad locomotives Pneumatic Fixed-volume, Grease pulses directed Reduces fuel consumption, R-07000

& hi-rail vehicles injector/airless- at wheel flange throat. wheel/rail wear and noise R-10000

Grease only spray nozzle Frequency based on by reducing wheel flange/rail

distance traveled or friction. 92-day reservoir

curve sensing. reservoir supply.

WheelMaster Rail-guided cranes N/A Solid lubricant Rugged mounting brackets Reduced flange, rail friction 13200

industrial locomotives block applied to custom designed for each reduces power requirements,

Grease only transit cars, other wheel flange by application, one applicator wear, noise. Low lubricant

equipment. spring-load. per side of equipment. consumption.

Trabon Stamping presses, Pneumatic Pump-to-point, air Individual air-stroked pump Corrosion-resistant com- 12150

Die-Lube other metal forming & less spray for each lube point; adjust- ponents compatible with

Oil & synthetic cutting machines. nozzles & orifices. able output; variety of water base fluids; quick

coolants/fluids spray patterns. change for different die

setups.

Manzel & Mega Compressors & gas Electric Pump-to-point, Individual cam-operated High reliability; injects oil 12506

engines, petrochemical Mechanical unitized reservoir plunger pump for each directly into high pressure 51020

Oil only equipment, lumber & pump drive. lube point, precision cylinder; retards formation 51030

mills, rubber mixing output adjustment; out- of carbon deposits 51040

machines. put to 60,000 psi

Sentinel Critical equipment Electric Series progressive Self-contained pump/ Flow below selectable S-80000

requiring constant flow actuated reservoir/divider valve level generates alarm

Oil only monitoring. divider valve. package with micro- signal and/or shuts down

processor flow monitor. equipment automatically.

Meter Mist Medium to high speed Pneumatic Single line parallel, Air/oil mist generator Coats all surfaces in 20112

machines w/enclosed feeds to nozzles attached to header enclosure; eliminates oil

Oil only bearings and gears. & fittings. line; air-over-oil reservoir churning associated with

with venturi mixing tube. oil flood systems.

Spindl-Gard Machine tool spindles, Electric, Series progressive Non-mist air/oil delivery Eliminate excessive lube, 20110

web process equipment Pneumatic or pump to point, for single or multiple reduces viscous shear (drag), 20110A

Oil only High speed bearings, Hydraulic wide or pinpoint spindle heads, speeds power requirements. Precise

gears. Mechanical spray nozzles, to 1.25 million DN. lube application. No mist to

monitoring. contaminate plant.

OPCO Overhead and in-floor Electric, Metering pump and Lubricators triggered by Eliminates costly labor. OP-60004

ChainMaster (inverted) chain-driven Pneumatic lines to nozzles or proximity switches. Metered Extends conveyor life. Re- OP-60008

Oil or grease conveyors. coupler. shot accuracy to pins, duces power & lube consump- OP-60201

links, trolly wheels, track tion. Power brush cleaner OP-61000

and rollers. minimizes contamination OP-61002

from overhead conveyors.

Mill-Gard Primary metals, Pulp, Electric, Series progressive Non-mist air/oil delivery Eliminates excessive lube, 20118

Paper & other web Pneumatic intermittent or for single or multiple reduces viscous shear (drag), 20118B

Oil only processes, mining, Hydraulic constant delivery, bearings and gear drives. reduces power requirements,

mineral processing. wide angle or pin precise lube application. No

Enclosed bearing & gears point. mist to contaminate plant.

Page 34: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

Page 30

Injecto-Flo® Piston Distributor System Components 12120

Part Catalog

Number Page

126-400-010 5

126-400-020 5

126-400-030 5

126-400-040 5

126-400-050 5

126-400-060 5

126-400-070 5

126-400-080 5

126-400-100 4

126-400-120 4

126-400-130 4

126-410-011 22

126-410-015 7

126-410-016 7

126-410-017 7

126-410-018 7

126-410-026 7

163-210-050 18

163-400-000 17

163-400-040 19

163-400-041 19

163-400-042 19

163-400-043 19

163-400-050 21

163-400-051 21

163-400-052 21

163-400-053 21

400-132-025 28

400-132-065 28

400-132-070 28

422-040-110 12 & 13

435 702-396 12 & 25

435-270-030 28

435-380-080 12 & 26

435-380-090 12 & 26

435-520-080 27

435-520-090 27

435-520-100 27

435-702-261 12

435-702-267 25

435-702-361 12 & 25

435-702-362 12 & 26

435-702-390 27

435-702-391 27

435-702-392 27

435-702-393 27

435-702-395 27

435-702-403 12 & 25

435-702-404 12 & 26

435-702-405 12 & 26

435-702-407 12 & 25

435-702-408 12 & 25

435-702-409 12 & 25

435-702-410 12 & 25

435-702-411 12 & 25

435-702-413 12 & 25

435-702-414 12 & 25

435-702-415 12

Part Catalog

Number Page

435-702-416 12 & 25

435-702-417 12 & 25

435-702-418 12 & 25

435-702-419 12 & 25

435-702-420 14

435-702-421 3, 4, 5, 7,

14 & 25

435-702-422 14

435-702-423 14 & 25

435-702-424 26

435-702-425 26

435-702-426 26

435-702-427 26

435-702-428 26

435-702-430 26

435-702-432 26

435-702-433 26

435-702-434 26

435-702-435 26

435-702-436 26

435-702-437 26

435-702-438 26

435-702-439 26

435-702-440 26

435-702-441 27

435-702-442 27

435-702-443 27

435-702-444 27

435-702-445 27

435-702-447 27

435-702-448 27

435-702-449 27

435-702-450 27

435-702-451 27

435-702-452 27

435-702-453 27

435-702-454 27

435-702-456 27

435-702-457 27

435-702-458 27

435-702-459 27

435-702-460 27

435-702-461 27

435-702-462 28

435-702-463 28

435-702-464 28

435-702-465 25

435-702-466 3, 4, 5,

7 & 25

435-702-469 25

435-702-471 25

435-702-472 25

435-702-473 25

435-702-474 26

435-702-475 26

435-702-476 12,26

Part Catalog

Number Page

435-710-010 28

435-710-020 28

435-710-030 28

435-710-040 28

443-700-030 28

443-700-031 28

443-700-032 28

443-700-033 28

443-700-034 28

443-700-035 28

473-000-231 22

473-000-232 22

482-000-348 23

482-000-463 23

482-000-464 23

492-240-130 17

493-020-198 22

493-120-040 22

493-120-045 22

493-120-050 22

500-981-000 28

500-982-000 28

500-983-000 28

500-984-000 28

509-110-000 26

509-111-000 26

509-112-000 26

509-113-000 26

509-114-000 26

509-170-000 23

509-200-000 23

509-201-000 23

509-202-000 23

509-204-000 23

509-205-000 23

509-210-000 23

509-211-000 23

509-212-000 23

509-213-000 23

509-214-000 23

509-215-000 23

509-220-000 23

509-221-000 23

509-222-000 23

509-222-010 23

509-222-020 23

509-225-000 23

527-101-150 22

527-101-160 22

534-335-000 22

550-151 000 11

550-151-001 11

550-151-002 11

550-151-010 11

550-151-011 11

550-151-012 11

550-151-013 11

I N D E XPart Catalog

Number Page

550-151-020 11

550-151-021 11

550-151-022 11

550-151-023 11

550-151-030 11

550-151-031 11

550-151-032 11

550-151-033 11

550-151-040 14

550-151-041 14

550-151-042 14

550-151-043 14

550-151-050 14

550-151-051 14

550-151-052 14

550-151-053 14

550-151-090 13

550-151-091 13

550-151-092 13

550-151-093 13

550-151-100 13

550-151-110 13

550-151-111 13

550-151-170 24

550-151-171 24

550-151-172 24

550-151-173 24

550-151-174 24

550-151-175 24

550-151-176 24

550-151-177 24

550-151-178 24

550-151-179 24

550-151-180 24

550-151-181 24

550-151-182 24

550-151-183 24

550-151-184 24

550-151-185 24

550-151-186 24

551-100-060 11

551-100-070 11

551-100-080 11

551-100-090 11

572-101-000 17

572-142-590 17

Page 35: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less
Page 36: Piston Distributor Lubrication Using Oil - Lube Systems of ...lubesystemsonline.com/graco/GRACO TRABON INJECTO-FLO 12120.pdf · Piston Distributor Lubrication ... resulting in less

LUBRIQUIP, INC., 18901 Cranwood Pkwy Cleveland, Ohio 44128 Phone: 216-581-2000 or 800-USA-LUBE FAX : 216-581-8945

R

Lubriquip endorses the SAE recommendation of ISO 18/14(ISO 4406) oil cleanliness for most bearing applications.Some high speed bearing may require cleaner oil. Consultthe bearing manufacturer for recommendation.

® Registered trademark of LUBRIQUIP, INC.,Printed in U.S.A.

Bulletin 12120Trabon® Injecto-Flo Piston Distributor System Components

www.lubriquip.com/pdf/12120.pdf