plans and drawings - eisdocs.dsdip.qld.gov.aueisdocs.dsdip.qld.gov.au/carmichael coal mine and...

49
> Camp Layout Package prepared by Cardno > Civil Engineering Drawings prepared by Cardno PART 10 PLANS AND DRAWINGS

Upload: trinhphuc

Post on 20-Aug-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

> Camp Layout Package prepared by Cardno

> Civil Engineering Drawings prepared by Cardno

PART

10 PLANS AND DRAWINGS

CAMP LAYOUT PACKAGE PREPARED BY CARDNO

ADANI MINING Pty Ltd Mine Camp

DATE DRAWING NO ISSUE

landscape architectureurban design

environmental management SP126801 -MC-01

RAIL CAMP TWORAIL CAMP

THREE

MINING CAMP

RAIL CAMP ONE

MORAHBAH

MORAY CARMICHAEL ROAD PROPOSED ACCESS ROAD

DISTANCE FROMMORAY CARMICHAEL ROADTO MINE CAMP1.0 KM

MINE CAMP

B22.10.12

TYPICAL SITE PHOTOS

LOCATION PLANSCALE 1:15,000 @ A3

FUTURE RAILWAY CORRIDOR

CONTEXTMINE CAMP

ADANI MINING Pty Ltd Mine Camp

DATE DRAWING NO ISSUE

landscape architectureurban design

environmental management SP126801 -MC-02 B22.10.12

LEGEND

MINE CAMP

ACCOMMODATION UNITS 504DISABLE UNITS 6CARPARKING 215 DISABLE CARPARKING 6BUS PARKING 6EFFLUENT DISPOSAL 5 ha(based on 100m2 per person)DETENTION BASINS 0.7haTOTAL OPEN SPACE 16.4ha(including firebreak) TOTAL SITE AREA 20.7 ha(excluding STP, WTP and laydown area)

ACCOMMODATION GROUP ISCALE 1 :1000

SCALE 1 :2,000

PLAN

0 1 2 3 5 10m

SCALE 1:250 @ A3

ADANI MINING Pty Ltd Mine Camp

DATE DRAWING NO ISSUE

landscape architectureurban design

environmental management B22.10.12 SP126801 -MC-03

MINE CAMP

Section O

ne

KEY

SECTIONS

SECT

ION

ON

E

PLANTED BUFFER ACCOMMODATION GROUP (24 PERSON)

Front of unitsSheltered walkway

Effluent Disposal Area

Effluent Disposal Area

Central spine path

Typical drainage swale

Covered Walkway

join

s be

low

join

s ab

ove

ACCOMMODATION GROUP (24 PERSON)

Sheltered walkway

Rear of units Private open space areafor each accommodation group

Private open space areafor each= accommodation group

PLANTED BUFFER DINING / KITCHEN COMMUNAL OPEN SPACE

Dining entry

Effluent Disposal Area

0 1 2 3 5 10m

SCALE 1:250 @ A3

ADANI MINING Pty Ltd Mine Camp

DATE DRAWING NO ISSUE

landscape architectureurban design

environmental management SP126801 -MC-04 B22.10.12

MINE CAMPSection Two

KEY

SECTIONS

SECT

ION

TW

O

CENTRAL PATH

CENTRAL PATH

Central covered walk-way connects to spine path

PLANTED BUFFER ( WITH ACCOMMODATION GROUP BEHIND) ACCOMMODATION GROUP (24 PERSON)

join

s be

low

join

s ab

ove

COMMUNAL OPEN SPACE

Units behind buffer

Private open space areafor each accommodation group

Communal Open Space with BBQ Facilities, Seating and Shelter

Private open space areafor each accommodation group

Breezway between units

Central covered walk-way connects to spine path

ACCOMMODATION GROUP (24 PERSON)

ADANI MINING Pty Ltd Mine Camp

DATE DRAWING NO ISSUE

landscape architectureurban design

environmental management

ADANI MINING CAMP

ATCO - 14.4 x 3.25M Three person doubleATCO - 14.4 x 3.25M VIP Two person DisabledATCO - 48.0 x 22.5 M Kitchen Diner (500 person)ATCO - 12.0 x 6.0 M OfficeATCO - 12.0 x 3.0 M Abulition BlockATCO - 12.0 x 3.0 M Linen StoreATCO - 12.0 x 12.0 M GymATCO - 18.0 x 12.0 M Recreation CentreATCO - 12.0 x 3.0 M Laundry

B22.10.12

MINE CAMPAPPENDICES

ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

Carmichael ProjectQLD.

Adani Mining Pty. Ltd.120842A2

14.4 x 3.25m VIP Three Person Double

- Drawing ListSheet

Number Sheet NameCurrentRevision

00 Title Page01 Floor Plan02 Elevations06 Sales Schedules

Views indicative only

fw

2

fw

2

fw

2

WP

WPWP

222

PE

RS RS RSTV 2 TV2TV2

dpdp dp

DSB

POE SMKTV

103

204

A

1 2 3 4

B

4802 4796 4802

8230

8682

TYPICAL DETAILAll Internal Fire / Sound Rated Wallsrun to outside wall faces.Refer Drg. L004

Rw

50(+

ctr)

SO

UN

D R

ATED

Rw

50(+

ctr)

SO

UN

D R

ATED

HWSISOLATOR

HWS EARTH

Stacked A/CCompressors

82 3613 86 945 152 3613 86 945 152 945 86 3613 82

304

3250 HWS

Steps indicated are indicative only

Stacked A/CIsolators

Single A/CCompressors

Stacked A/CIsolators

x

W19081200

x

W2750350

8

73

2

1

12

1310

11

9

654

x

D12040

820

M0

M1 M1

2

1

8

7

1210139

x

D12040

820

x

W19081200

M2 M2

x

W2750350

11

3

654

600

AFL

600 AFL

1280 AFL

1280

AFL

1280

AFL

1280

AFL

Key

Tag

150

0 AF

LLi

ght S

witc

h 12

80 A

FL

1280

AFL

1280 AFL

1400 AFL

1280 AFL

No Item Numbers in this end,.Electrical fixture heights showninstead.

203

M0

14400

M1

Waste manifold to discharge backside centre

RETICULATION POINTSMOKETV

M0

9 9

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

Carmichael ProjectQLD.

1 : 50

9/10

/201

2 10

:34:

26 A

M

Adani Mining Pty. Ltd.14.4 x 3.25m VIP Three Person Double

TK

RA

120842A2 -01

09.10.12

Floor Plan Reg. C Cat. 2

3

Plumbing - Waste Manifold OutletPlumbing - Water Inlet c/w Line Strainer

1 945 x 945 Fibreglass shower cubicle / Curtain. 3 Star WELS2 Hand Basin VC c/w Mirror Over - NOVATEC CARA inc.

overflow & PVC Waste3 WC Suite 4.5 Star WELS, c/w toilet roll holder4 Shaving Cabinet c/w 2 mirrored doors5 Towel Rail - 600w6 Two Coat Hooks on Timber Rail x 600w7 395w x 390d x 590h Bedside Three Drawer Unit8 Double bed c/w innerspring mattress9 1800h x 800w x 600d Robe c/w Shelves & Hanging Space10 Step Desk11 Shelving Over Desk - 1200mm Long Open12 Steel framed stacker chair13 Bar Fridge - WESTINGHOUSE - WRM1300WC - 130 litre14 9.0Kg Fire Extinguisher - AB(E)dp Dropper only, for 100 x 75mm Downpipefw Floor Waste

HWS Rheem Heat Pump 325 Litre/6kW -MPi - mounted externally

Item Lists

D1 2040 x 820 External Door - Standard : Hollow Core MCD2 2040 x 720 Internal Door - Standard : Hollow Core

W1 1200 x 908 Sliding Glass Window Grey GlassW2 350 x 750 Sliding Glass Window Obscure Glass

M0 A/C Vertical Two Piece CoverM1 2.5kW R/C Split System Air Conditioner - HybridM2 Wall Mounted Exhaust Fan

- Building designed in accordance with Queensland DevelopmentCode (QDC) MP3.3 - Temporary accommodation buildings andstructures.- Smoke Alarms and TV Outlets are reticulated to common point.- Exhaust fan and light in ensuite to be operated from same switch- Sound rated walls to run into roof cavity - refer to drawing details.

Notes

Energy Efficiency Notes- The design above is compliant for climate zones 1 & 3 for allorientations. Any changes to windows and/or external door sizes,quantity or locations will require re-submission for energy efficiencycompliance.- Under floor insulation not required under section P2 of QDC MP3.3 -Temporary Accommodation Building and Structures- For climate zones other than 1 & 3, energy efficiency calculation issubject to geographic location & site orientation.

Item Lists

Rev Description Date By

240V Smoke detector

Distribution Switchboard

External light18W Single Vandalite

36w Single fluorescent light

15amp Single GPO.10amp Double GPO10amp Single GPO

36w Single fluorescent light - IP65 rated

36w Double fluorescent light

10amp GPO - IPX5 rated

Comms. - Draw wire only

Light switchTwo-way light switch

Photo electric light switch

Spot light

'F' Type television outlet

Oyster light

Light switch - IPX5 rated

20amp Single GPO

Emergency exit light

Oyster Light - 11W Round Fluro

36w Emergency back-up fluorescent light

POE - Point Of Entry

- Indicates floor mounting- Indicates ceiling mounting

DSB

IPX5

IPX5

WP

EXIT

PE

Symbol Legend

2

Isolation Switch

PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point

FFL

0

Ceiling

2445

GL

-525

FFL

0

Ceiling

2445

GL

-525

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

Carmichael ProjectQLD.

1 : 75

9/10

/201

2 10

:34:

34 A

M

Adani Mining Pty. Ltd.14.4 x 3.25m VIP Three Person Double

TK

RA

120842A2 -02

09.10.12

Elevations Reg. C Cat. 2

3

1 : 75

Elevation AA

1 : 75

Elevation BB

2° Skillion Roof

Panelrib External Cladding

Aluminium Framed Windows

Metal Clad External Doors

310UB Skid Beams

1 : 75

Elevation C1

1 : 75

Elevation D2

Rev Description Date By

Reticulation PointsSmoke

POETV

PE Cell

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

Carmichael ProjectQLD.

9/10

/201

2 10

:34:

36 A

M

Adani Mining Pty. Ltd.14.4 x 3.25m VIP Three Person Double

TK

RA

120842A2 -06

09.10.12

Sales Schedules Reg. C Cat. 2

3

Sales Window Schedule

No. Type Glazing Height WidthSill

Height Quantity CommentsW1 Sliding XO Grey Glass 1200 908 1000 3 c/w CurtainsW2 Sliding XO.. Obscure Glass 350 750 1650 3

Sales Roof Structure ScheduleRoof Structure Comments

2° Skillion RoofC2 - SDEK/PLY LC7512 - 611 - (3.0 & 3.5)611mm Ceiling Joist CentresCeiling Joist - LC7512 GalvaspanInsulation - R2.3 Foil Backed Blanket - 95mmLining - Internal - 3.6mm Polyester CoatedPlywoodPurlins - C7510 / LC7512 GalvaspanRoof - 0.42mm BMT Superdek Roofing

- Wall ScheduleWall Structure Comments

External Wall407mm Stud CentresCladding External - Colorbond Maxirib -"Headland"

Lower

Cladding External - Colorbond Maxirib -"Paperbark"

Upper

Framing - 75 x 1.0mm Hi-Ten TruecoreInsulation - R2.9 Batts - 75mmLining - Internal - 3.6mm Polyester CoatedPlywoodThermal Break between Framing and CladdingInternal Wall - Fire / Sound Rated - Rw50 (+Ctr)611mm Stud CentresFraming - 92 x 0.5 'RHONDO' Quiet StudInsulation - R1.8 75mm Fibreglass Batt(14kg/m³)Lining - 2 x Layers 13mm Fyrecheck to bothsidesLining - Internal - 3.6mm Polyester CoatedPlywood (Finish layer to each side)Ply Internal Wall611mm Stud CentresFraming - 75 x 1.0mm Hi-Ten TruecoreLining - Internal - 3.6mm Polyester CoatedPlywood

* Plumbing FixturesNo. Description Quantity Comments

Plumbing - Waste Manifold Outlet 1Plumbing - Water Inlet c/w Line Strainer 1

1 945 x 945 Fibreglass shower cubicle / Curtain. 3Star WELS

3 Hot & Cold

2 Hand Basin VC c/w Mirror Over - NOVATECCARA inc. overflow & PVC Waste

3 Hot & Cold

3 WC Suite 4.5 Star WELS, c/w toilet roll holder 34 Shaving Cabinet c/w 2 mirrored doors 3dp Dropper only, for 100 x 75mm Downpipe 3fw Floor Waste 3

HWS Rheem Heat Pump 325 Litre/6kW -MPi -mounted externally

1

Lighting Fixtures Quantity1x18w Fluro - IP65 31x36W Fluro - Bare 3Reading Light - Oyster Shape 6Single Vandalite - Wall Mounted 2Switch - Key tag 3Switch - Std 12

- Electrical FixturesDescription Quantity

1x10amp GPO 32x10amp GPO 9240v Smoke Alarm 3External Smoke Junction Box 1External TV Junction Box 1Isolation Switch - AC 3Isolation Switch - HWS 1Photo Electric Cell 1Reed Switch 3Switchboard 1TV Antenna Socket 3

- FurnitureNo. Description Quantity Comments

5 Towel Rail - 600w 6 2 coat hooksabove / rail

6 Two Coat Hooks on Timber Rail x 600w 67 395w x 390d x 590h Bedside Three Drawer Unit 38 Double bed c/w innerspring mattress 39 1800h x 800w x 600d Robe c/w Shelves &

Hanging Space6

10 Step Desk 3 c/w space forBar Fridge

12 Steel framed stacker chair 3

- CupboardsNo. Description Quantity Comments11 Shelving Over Desk - 1200mm Long Open 3

Sales Mechanical EquipmentNo. Supplier Description QuantityM0 A/C

InstallerA/C Vertical Two Piece Cover 3

M1 DAIKIN 2.5kW R/C Split System Air Conditioner -Hybrid

3

M2 AIRFLOW Wall Mounted Exhaust Fan 3

- Floor Structure ScheduleFloor Structure Comments

Floor480mm Floor Joist CentresCovering - 1.5mm Polyflor XL Vinyl 100mm Cove -

BathroomFlooring - 17mm F11 T&G PlywoodJoists - LC10015 Galvaspan

Wall Height2445

- Electrical Equipment ScheduleNo. Description Quantity Comments13 Bar Fridge - WESTINGHOUSE - WRM1300WC -

130 litre3

- Fire Services ScheduleNo. Description Quantity14 9.0Kg Fire Extinguisher - AB(E) 2 1

Manufacturing Structural Members

DescriptionMember

SizeBack to

BackSingle Skid beams c/wRetractable lifters

310UB 2000

Sales Door Schedule

No. Panel Height WidthHandleType

HardwareSet Closer

PanicBar

C/BJamb

TimberJamb Security Quantity Comments

D1 Standard : Hollow Core MC 2040 820 Standard Entrance No No Yes No 3 Weather and E/E SealsD2 Standard : Hollow Core 2040 720 Standard Privacy No No Yes No 3

** Under floor insulation not required under section P2 of **QDC MP3.3 - Temporary Accommodation Building and

Structures

Refridgeration Pipes to run under floor

SWITCHBOARD: To have timer installed, via. Door Reed Switch,for all A/C units.Units to be shut down if door left open for more than 1 minute.

Rev Description Date By

ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

Carmichael ProjectQLD.

Adani Mining Pty. Ltd.120842A1

14.4 x 3.25m VIP Two Person - Disabled

- Drawing ListSheet

Number Sheet NameCurrentRevision

00 Title Page01 Floor Plan02 Elevations07 Sales Schedules

Views indicative only

fw

WP2

fw

WP 2

22 22 22

RSRS 222 2

dp dpdp

DSB

POESMKTVPE

103

205

A

1 2 3

B

7200 7200

8230

8682

HWSISOLATOR

HWS EARTH

305

3250 HWS

1000

AFL

Ligh

t Sw

itch

1000

AFL

No Item Numbers in this end,.Electrical fixture heightsshown instead.

x

D22040

1200

9

4

13

78

5

10

M2

11

1000 AFFL

1000 AFFL

1000

AFF

L

1000

AFF

L

1280

AFF

L

1100

AFF

L

123

AB

C

D

6

RETICULATION POINT

SMOKETV

82 4400 86 2589 86 2589 86 4400 82

2

x

W11208900

x

D12040

920

x

W21200350

x

W11208900

1000 AFFL

1280 AFFL

1100

AFF

L10

00 A

FFL

1400

AFL

1000

AFL

14400

203

FE

M0 M0

VIEWS

M1

RETICULATION POINTSMOKETV

Waste manifold to discharge backside centre

1240

OPTION

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

Carmichael ProjectQLD.

1 : 50

22/0

8/20

12 3

:01:

29 P

M

Adani Mining Pty. Ltd.14.4 x 3.25m VIP Two Person - Disabled

TK

RA

120842A1 -01

20.08.12

Floor Plan Reg. C Cat. 2

3

Plumbing - Waste Manifold OutletPlumbing - Water Inlet c/w Line Strainer

1 Disabled WC Suite - 2011, Grab Rails & Backrest2 Disabled Shower Type II - 2011 - c/w Fold-Up Seat & Grab Rails3 Chrome plated towel rail4 Disabled Vanity Unit c/w Laminated Bench Top & 1000 x 600

mirror over5 Mini Folding Frame Clothesline6 Washing Machine/Dryer Combo - Ariston ARMF125 on 300h plinth7 Washing Machine Taps8 Washing Machine Discharge Pipe9 King single bed c/w innerspring mattress10 Disabled Wardrobe - 2 Drawers11 Disabled Stepped Desk 1800 x 60012 Two Coat Hooks on Timber Rail x 600w13 Bar Fridge - WESTINGHOUSE - WRM1300WC - 130 litredp Dropper only, for 100 x 75mm DownpipeFE 9.0Kg Fire Extinguisher - AB(E)fw Floor Waste

HWS Rheem Heat Pump 325 Litre/6kW -MPi - mounted externally

Item ListsD1 2040 x 920 External Door - Standard : Hollow Core MCD2 2040 x 1200 Internal Door

-Standard : Sliding Hollow Core

W1 900 x 1208 Sliding Glass Window - Grey GlassW2 350 x 1200 Sliding Glass Window Obscure Glass

M0 A/C Vertical Two Piece CoverM1 Wall Mounted Exhaust FanM2 3.62kW R/C Split System Air Conditioner

- Building designed in accordance with Queensland DevelopmentCode (QDC) MP3.3 - Temporary accommodation buildings andstructures.

- Smoke Alarms and TV Outlets are reticulated to common point.- Exhaust fan and light in ensuite to be operated from same switch- Sound rated walls to run into roof cavity - refer to drawing details.

Notes

Energy Efficiency Notes- The design above is compliant for climate zones 1 & 3 for allorientations. Any changes to windows and/or external door sizes,quantity or locations will require re-submission for energy efficiencycompliance.- Under floor insulation not required under section P2 of QDC MP3.3 -Temporary Accommodation Building and Structures- For climate zones other than 1 & 3, energy efficiency calculation issubject to geographic location & site orientation.

Item Lists

Rev Description Date By

240V Smoke detector

Distribution Switchboard

External light18W Single Vandalite

36w Single fluorescent light

15amp Single GPO.10amp Double GPO10amp Single GPO

36w Single fluorescent light - IP65 rated

36w Double fluorescent light

10amp GPO - IPX5 rated

Comms. - Draw wire only

Light switchTwo-way light switch

Photo electric light switch

Spot light

'F' Type television outlet

Oyster light

Light switch - IPX5 rated

20amp Single GPO

Emergency exit light

Oyster Light - 11W Round Fluro

36w Emergency back-up fluorescent light

POE - Point Of Entry

- Indicates floor mounting- Indicates ceiling mounting

DSB

IPX5

IPX5

WP

EXIT

PE

Symbol Legend

2

Isolation Switch

PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point

FFL

0

Ceiling

2445

GL

-525

FFL

0

Ceiling

2445

GL

-525

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

Carmichael ProjectQLD.

1 : 75

22/0

8/20

12 3

:01:

37 P

M

Adani Mining Pty. Ltd.14.4 x 3.25m VIP Two Person - Disabled

TK

RA

120842A1 -02

20.08.12

Elevations Reg. C Cat. 2

3

1 : 75

Elevation AA

1 : 75

Elevation BB

2° End to End Roof

Panelrib External Cladding

Aluminium Framed Windows

Metal Clad External Doors

310UB Skid Beams

1 : 75

Elevation C1

1 : 75

Elevation D2

Rev Description Date By

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

Carmichael ProjectQLD.

22/0

8/20

12 3

:01:

39 P

M

Adani Mining Pty. Ltd.14.4 x 3.25m VIP Two Person - Disabled

TK

RA

120842A1 -07

20.08.12

Sales Schedules Reg. C Cat. 2

3

Sales Window Schedule

No. Type Glazing Height WidthSill

Height Quantity CommentsW1 Sliding XO Grey Glass 900 1208 1000 2 c/w CurtainW2 Sliding XO.. Obscure Glass 350 1200 1960 2

Sales Roof Structure ScheduleRoof Structure Comments

2° End to End RoofC2 - SDEK/PLY LC7512 - 611 - (3.0 & 3.5)611mm Ceiling Joist CentresCeiling Joist - LC7512 GalvaspanInsulation - R2.3 Foil Backed Blanket - 95mmLining - Internal - 3.6mm Polyester CoatedPlywoodPurlins - C7510 / LC7512 GalvaspanRoof - 0.42mm BMT Superdek Roofing

- Wall ScheduleWall Structure Comments

External Wall611mm Stud CentresCladding External - Colorbond Maxirib -"Headland"

Lower

Cladding External - Colorbond Maxirib -"Paperbark"

Upper

Framing - 75 x 1.0mm Hi-Ten TruecoreInsulation - R2.9 Batts - 75mmLining - Internal - 3.6mm Polyester CoatedPlywoodThermal Break between Framing and CladdingPly Internal Wall611mm Stud Centres75mm Glasswool batt to wall hatchedFraming - 75 x 1.0mm Hi-Ten TruecoreLining - Internal - 3.6mm Polyester CoatedPlywood

* Plumbing FixturesNo. Description Quantity Comments

Plumbing - Waste Manifold Outlet 1Plumbing - Water Inlet c/w Line Strainer 1

1 Disabled WC Suite - 2011, Grab Rails &Backrest

2

2 Disabled Shower Type II - 2011 - c/w Fold-UpSeat & Grab Rails

2

3 Chrome plated towel rail 24 Disabled Vanity Unit c/w Laminated Bench Top

& 1000 x 600 mirror over2 c/w Mirror. Disabled Compliant

5 Mini Folding Frame Clothesline 2 Set 1200 AFFL7 Washing Machine Taps 28 Washing Machine Discharge Pipe 2dp Dropper only, for 100 x 75mm Downpipe 3fw Floor Waste 2

HWS Rheem Heat Pump 325 Litre/6kW -MPi -mounted externally

1

Lighting Fixtures Quantity1x36W Fluro - Bare 21x36W Fluro - IP65 2Reading Light - Oyster Shape 4Single Vandalite - Wall Mounted 2Switch - Std 8

- Electrical FixturesDescription Quantity

1x10amp GPO AC 21x15amp GPO AC 22x10amp GPO 12240v Smoke Alarm 2Draw Wire 2External Smoke Junction Box 1External TV Junction Box 1Isolation Switch - HWS 1Photo Electric Cell 1Reed Switch 2Switchboard 1

- FurnitureNo. Description Quantity Comments

9 King single bed c/w innerspring mattress 210 Disabled Wardrobe - 2 Drawers 2 Disabled Compliant 1 Lh & 1 RH11 Disabled Stepped Desk 1800 x 600 212 Two Coat Hooks on Timber Rail x 600w 2

Sales Mechanical EquipmentNo. Supplier Description QuantityM0 A/C

InstallerA/C Vertical Two Piece Cover 2

M1 AIRFLOW Wall Mounted Exhaust Fan 2M2 TECO 3.62kW R/C Split System Air Conditioner 2

- Floor Structure ScheduleFloor Structure Comments

Floor600mm Floor Joist CentresCovering - 2.0mm Polyflor Non-Slip Vinyl Bathrooms -

100mm CoveCovering - 2.0mm Polyflor XL Vinyl BedroomsFlooring - 17mm F11 T&G PlywoodInsulation - Under Floor - 15mm FoilboardJoists - LC10015 Galvaspan

Wall Height2445

- Electrical Equipment ScheduleNo. Description Quantity Comments

6 Washing Machine/Dryer Combo - Ariston ARMF125 on 300h plinth 213 Bar Fridge - WESTINGHOUSE - WRM1300WC - 130 litre 2

- Fire Services ScheduleNo. Description QuantityFE 9.0Kg Fire Extinguisher - AB(E) 2 1

Manufacturing Structural Members

DescriptionMember

SizeCentre to

CentreSingle Skid beams c/wRetractable lifters

310UB 2000

Sales Door Schedule

No. Panel Height WidthHandleType

HardwareSet Closer

PanicBar

C/BJamb

TimberJamb Security Quantity Comments

D1 Standard : Hollow Core MC 2040 920 Lever Entrance No No Yes No 2 E/E & Weather SealsD2 Standard : Sliding Hollow Core 2040 1200 Privacy No Yes 2 Flush Pull Handle

Refridgeration Pipes to run under floor

SWITCHBOARD: To have timer installed, via. Door Reed Switch,for all A/C units.Units to be shut down if door left open for more than 1 minute.

Rev Description Date By

OPTIONOPTION

OPTION

OPTION

OPTION

OPTION

OPTION

OPTION

OPTION

ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

KD-500-H-C2

Kitchen Diner - 48.0 x 22.5m

ATCO Structures & Logistics Pty Ltd

- Drawing ListSheet

Number Sheet NameCurrentRevision

00 Title Page A01 Floor Plan A02 Elevations A05 Kitchen Sections A07 Sales Schedules A

View indicative only

COOKING CAPACITY = 500 PersonSEATING CAPACITY = 300 Person

fw

IPX5

fw

fw

fw

fw

IPX5

fw

fw

fw

fw

fw

PEPOE POE POE POE POE

DSB

POE

DSB

POE

WP

WP

WP

WP

BUG

EXI

T

EXIT

EXIT

EXI

T

BUG

2

2

2

222222

2222

2

2

2

WP

WP

WP

WP

fw

WP

WP

DSB

POE

2

2

PE

EXI

T

2

2

2

S S

S S

DSB

POE

DSB

POE

DSB

POE

DSB

POE

DSB

POE

DSB

POEdp dp dp dp dp dp dp dp dpdp dp dp dp dp dp dp

dp dp dp dp dp dp dp dp dp dp dp dp dp dp dp

BUG

2

2

DSBP

OE D

SBPO

E

dp

dpdp 2

dpPE

EXI

T

BUG

fw

fw

fw

2

DSBP

OE

dp

fw

BUG

EXIT

104

204

A

1

1

2

2

3 4 5

B

03

03

02

02

01

01

0

0

06 05 04 6 7 8 907

M9M10M10

29

FREEZER

DRYSTORECHILLER

9

10

11

11

12

5

13

13

1 1

2221

3

19a

40

2424

24a

25

VEGETABLE

MEAT

BAKERY

32

3534

3534

M5

26

x

D22040

1740 x

D12040

1840

M1

M1

M1

M1

x

D52040

920

x

D42040

920

x

O242001200

C20

020

Pai

red

Bea

ms

x

O110001200

23

C30

030

Stiff

ened

& C

ambe

red

Pai

red

Bea

ms

x

W31200350

x

W11208900

M3

x

W11208900x

W11208900x

W11208900

M4

4

M2

x

W11208900

CO

VER

ED L

OA

DIN

G D

OC

K

304

105

205

305

405

505

605

705

805

159 2837 168 2832 6000 3000 3000 168 26834 82

8211

837

82 8211

837

82

Freezer 2800

200

Col

droo

ms

480

020

00C

old

Roo

ms

4800

200

1200

015

0090

00

48000

3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000

DSBDSB

DSB

3130

31 313030

31

3130

30

HWSHWS

3130

31 313030

31

3130

30

2

3

4

215b15a

15b

3

3000

C

E

D

3000

3000

3000

604

14 14

1200

0

FREEZER

CHILLER

FREE

ZER

CH

ILLE

R

DRYSTORE

x

D52040

920

M2

DSB DSB

x

W11208900

x

W11208900

M3

M3

31 313030

31 313030

31 313030

31 313030

31 313030

31 313030

31 313030

31 313030

31 313030

31 313030

31 313030

31 313030

31 313030

31 313030

31 313030

31 313030

31 313030

31 313030

3130

3130

3130

3130

M11 M11

M9

27

25

Freezer 2800 Freezer / Chiller 2800

Covered Entry/Exit- Indicative Only

x

D71900

800

x

D71900

800x

D61900

800

x

D61900

800x

D61900

800

x

D71900

800

x

D71900

800

12000 12000 24000

3000

4500

2000

1200

12

19b25

DISH RETURN

HC

HC

17a

17a 17a

17a

17c17c

17b

17a

17a17a

17c 17c

17b

17a

28

Freezer 2800Freezer 2800

Chiller 2868Chiller 2800

Covered Entry/Exit- Indicative Only

3636

1

C30030 Stiffened & Cambered Paired Beams

x

W11208900

x

D12040

1840

x

W11208900

141

14

1

M1

M12222

15b15b

15b

Covered Entry/Exit- Indicative Only

4500

2000

8288

3782

9000

283435

x

O32040

1837

2020 20

8

8a

3333

18a

18b

18a 18a

18b

18a 18a 18a

18b18b

18a 18a

18d

18g 18g

18g

18d

18f

18e

18a

18c

18a18a

18c

18a18a

18c

18a18a

18c

18a

18d

7j

7f

7c

7b

7h

7a

6b

2

22a

22a

Flus

hFl

ush

Flus

hFl

ush

Flus

h

M3

x

D12040

1840 28

F

M3

x

D42040

920

M4

x

W11208900

M4

114

11

M3M3M3M3M3

x

W11208900

x

W11208900

M3

x

W11208900

M3

x

W11208900

M3

x

W11208900

M3

x

W11208900

M3

x

W21208600

M3

x

W21208600

M3

M4

x

W11208900

x

W11208900

M4

M4

x

W11208900

3000

6000

2000

3000

320

2780

2120

2080

3600

2080

2120

16a16

40

24

6a

M6M7

x

O32040

1837

x

D32040

820

82 11837 82

12000

M1 M1

2250

0

7d

M8

41

THIS DRAWING REMAINS THE PROPERTY OF ATCOSTRUCTURES PTY. LTD. IT MAY NOT BE REPRODUCED

OR COPIED WHOLE OR IN PART WITHOUT WRITTENAUTHORITY

© COPYRIGHT

QUALITY CERTIFIED TO AS/NZS ISO 9001:2008BY

SCI-QUAL INTERNATIONAL REGN No. 531

PROJECT No.

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER REVISION SHEET SIZE

A1

DESIGN WIND LOAD

ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD,

QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD

4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

1 : 100

12/0

9/20

12 9

:17:

27 A

M

A

ATCO Structures & Logistics Pty Ltd

Kitchen Diner - 48.0 x 22.5m

TK

RA

KD-500-H-C2 -01

31.05.12

Floor Plan

Reg. C Cat. 2 6

- Fire fighting equipment supplied & installed by others.- Freezer & Chillers to comply with NCC G.12

Notes

1 : 100

Floor Plan1

18a Shelving 4 Tier Post Style with ABS Shelves - 1800h x1500w x 600d

18b Shelving 4 Tier Post Style with ABS Shelves - 1800h x1200w x 600d

18c Shelving 4 Tier Post Style with ABS Shelves - 1800h x1350w x 600d

18d Shelving 4 Tier Post Style with ABS Shelves - 1800h x750w x 600d

18e Shelving 3 Tier Post Style with ABS Shelves - 1200h x1200w x 600d

18f Shelving 3 Tier Post Style with ABS Shelves - 1200h x600w x 600d

18g Shelving 4 Tier Post Style with ABS Shelves - 1800h x1200w x 600d

19a Planetary Mixer - 40 litre19b Planetary Mixer - 20 litre20 Hand Basin, Stainless Steel - Knee Operated (Hot & Cold)21 Semi Automatic Slicer22 Two Glass Door Chiller - 1120 Litres22a Single Glass Door Chiller - 600 Litres24 600 x 450 x 380 deep Sink c/w Pot Wash Item 4024a 600 x 450 x 380 deep Sink c/w Flickmixer25 450 x 450 x 300 deep Sink c/w Flickmixer26 Tubular Tray Race x 4200w27 Pot Rack 4 Tier Post Style with Wire Grid Shelves 1800h x

1200w x 600d28 4 Tap Stainless Steel Wash Trough 1800mm long29 Cleaners sink with hinged grate (Hot & Cold Tap Only)30 Steel Framed Stacker Chair31 1800 x 750 Melamine lunch table32 Potato Peeler33 Infill Bench - 450w 750d (300 high Splashback)34 9.0Kg Fire Extinguisher - AB(E)35 Fire Blanket36 Ice Cream Freezer - 183 Litre40 Pot Wash - Hob Mounted Pre Rinse & Add On Pot Filler41 MicrowaveBUG Electronic Bug Killer - 2 x 20Wdp Dropper only, for 100 x 75mm DownpipeDSB Switchboardfw Commercial Floor WasteHC Hose CockHWS 315Ltr Triple element hot water system - mounted

externally

Plumbing - Water Inlet c/w Line Strainer1 Salad Bar - 6 Mod - Storage Under / Glass Canopy2 Drinks Dispenser - 4 x 12 Litre3 Conveyor Toaster4 BIRKO 15ltr Autoboiler5 Rack - Conveyor Dishwasher6a Dish Return c/w Scraps Hole / Chute (1400 x 2825 x 2900)

(300 high Splashback with 600 high wall cover)6b Dishwash Exit - 1500 x 700 (300 high Splashback with

600 high wall cover)7a Prep Bench - Meat 01 x 2700w (300 high Splashback)7b Prep Bench - Meat 02 x 4200w (300 high Splashback)7c Prep Bench - Bakery 01 x 3200w (300 high Splashback)7d Prep Bench - Bakery 02 x 4000w (300 high Splashback) to

inc. 600 Stepdown x 700w7f Prep Bench - Vege 01 x 4000w inc. Stepdown7h Mobile Bench - Meat x 1200w (No Splashback)7j Mobile Bench - Vege x 1200w (No Splashback)8 Combi Oven - Electric8a Combi Oven - Electric9 Tilting Bratt Pan - Electric - 150 Litre10 Deep Fryer - Electric - 3 Pan x 21 Litre11 Griddle - Electric12 Range - Electric - 8 Element13 Hot Bain Marie - 6 Mod - Heated Storage Under / Sneeze

Guard14 Mobile Bench - Diner x 1800w x 750d x 900h (No

Splashback)15a Beverage Bench x 2850w (600 high Splashback)

Splashback to LH side15b Beverage Bench x 2900w (600 high Splashback)16 Prep Bench - Cooking x 2900w (300 high Splashback)16a Prep Bench - Cooking - Shelf x 2900w17a Shelving 4 Tier Post Style with Wire Grid Shelves 1800h x

1800w x 600d17b Shelving 4 Tier Post Style with Wire Grid Shelves 1800h x

1500w x 600d17c Shelving 4 Tier Post Style with Wire Grid Shelves 1800h x

1200w x 600d

Item ListsD1 2040 x 1840 External Double Door - Standard : Hollow Core MCD2 2040 x 1740 External Double Door - Standard : Hollow Core MCD3 2040 x 820 External Door - Standard : Hollow Core MCD4 2040 x 920 Internal Door - Half Glass : Solid CoreD5 2040 x 920 Internal Door - Half Glass : Hollow CoreD6 1900 x 800 Internal Door - Standard : Coldroom Panel DoorD7 1900 x 800 Internal Door - Standard : Freezer Panel DoorO3 Opening Only - 2040 x 1837 Opening Only

O1 1200 x 1000 Window opening Dish ReturnO2 1200 x 4200 Servery Servery WindowW1 900 x 1208 Sliding Glass Window - Grey GlassW2 600 x 1208 Sliding Glass Window - Obscure GlassW3 350 x 1200 Sliding Glass Window Obscure Glass

M1 900mm Air CurtainsM2 3.5kW R/C Split System Air Conditioner - InverterM3 5.0kW R/C Split System Air Conditioner - InverterM4 7.1kW R/C Split System Air Conditioner - InverterM5 Fresh Air Dual Kitchen Induction SystemM6 Exhaust Canopy - Main x 6300wM7 Exhaust Canopy - Secondary x 5400M8 Vent Hood for ES100 Rack - Conveyor DishwasherM9 External Compressors - Freezer / ChillerM10 External Compressor - FreezerM11 External Compressor - Chiller

Rev Description Date ByA Issed for Review 04.09.12 RA

COOKING CAPACITY = 500 PersonSEATING CAPACITY = 300 Person

C2 STRUCTURAL NOTES - Minimum Design Criteria

Dead and Live Windloads in accordance with the latest version of AS1170.2Wind Region: C - Terrain Category: 2Strength Design Wind Speed: Vu = 61.2m/s (61)Serviceability Wind Speed: Vs = 39.5m/s (39)Shielding Multiplier: 1.0 Topographic Multiplier: 1.0Earthquake Loads in accordance with the latest version of AS1170.4

WINDOW SPECIFICATIONULS (ULTIMATE) - 4.44kPASLS (SERVICEABILITY) - 1.33kPAWATER PENETRATION - 450PA

EXIT

240V Smoke detector

Distribution Switchboard

External light18W Single Vandalite

36w Single fluorescent light

15amp Single GPO.10amp Double GPO10amp Single GPO

36w Single fluorescent light - IP65 rated

36w Double fluorescent light

10amp GPO - IPX5 rated

Comms. - Draw wire only

Light switchTwo-way light switch

Photo electric light switchSpot light

'F' Type television outlet

Oyster light

Light switch - IPX5 rated

20amp Single GPO

Emergency exit lightOyster Light - 11W Round Fluro

36w Emergency back-up fluorescent light

POE - Point Of Entry

- Indicates floor mounting- Indicates ceiling mounting

DSB

IPX5

IPX5

WP

PE

Symbol Legend

2

Isolation Switch

PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point

FFL

0

Ceiling

2445

GL

-775

12345 0302010 0605046789 07

FFL

0

Ceiling

2445

GL

-775

1 2 3 4 503 02 01 006 05 04 6 7 8 907

FFL

0

Ceiling

2445

GL

-775

ABCE DF

FFL

0

Ceiling

2445

GL

-775

A B C ED F

THIS DRAWING REMAINS THE PROPERTY OF ATCOSTRUCTURES PTY. LTD. IT MAY NOT BE REPRODUCED

OR COPIED WHOLE OR IN PART WITHOUT WRITTENAUTHORITY

© COPYRIGHT

QUALITY CERTIFIED TO AS/NZS ISO 9001:2008BY

SCI-QUAL INTERNATIONAL REGN No. 531

PROJECT No.

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER REVISION SHEET SIZE

A1

DESIGN WIND LOAD

ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD,

QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD

4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

As indicated

12/0

9/20

12 9

:18:

16 A

M

A

ATCO Structures & Logistics Pty Ltd

Kitchen Diner - 48.0 x 22.5m

TK

RA

KD-500-H-C2 -02

31.05.12

Elevations

Reg. C Cat. 2 6

1 : 100

Elevation AA

1 : 100

Elevation BB

2° End to End Roof

Panelrib External CladdingAluminium Framed Windows

Metal Clad External Doors

200PFC Skid Beams

Rev Description Date ByA Issed for Review 04.09.12 RA

1 : 50

Elevation C1

1 : 50

Elevation D2

FFL

0

Ceiling

2445

GL

-775

AB

2

C AB

35

34 13 13

15a

M4

C

FFL

0

Ceiling

2445

GL

-775

A B

Energy Efficiency andEmergency Lighting ControlPanel

Cooking Equipment Isolator

EMERGENCY STOP

DishReturn

Canopy /SupplyAir Fan

COOKINGDISHWASH

13 13

900

AB

Stainless Steel Sheet to wall - floor to underside of canopy, full lengthof canopy and to full width of canopy on end wall

COOKINGDISHWASH

C

Emergency Stop

12 11 11 33 105

6b

4080

M8

FFL

0

Ceiling

2445

GL

-775

A BStainless Steel Sheet to wall - floorto underside of canopy, full widthof canopy

VEGETABLEMEAT

HWS

Emergency Stop

27

12 98 8a

7a 7h7j

FFL

0

Ceiling

2445

GL

-775

AB

2132

Energy Efficiencyand EmergencyLighting ControlPanel

Cooking Equipment IsolatorEMERGENCY STOP

Canopy fan

VEGETABLEMEAT

1330

1440 17

00

FFL

0

Ceiling

2445

GL

-775

A B

34

35

22

19b

7c

FFL

0

Ceiling

2445

GL

-775

AB

19a

THIS DRAWING REMAINS THE PROPERTY OF ATCOSTRUCTURES PTY. LTD. IT MAY NOT BE REPRODUCED

OR COPIED WHOLE OR IN PART WITHOUT WRITTENAUTHORITY

© COPYRIGHT

QUALITY CERTIFIED TO AS/NZS ISO 9001:2008BY

SCI-QUAL INTERNATIONAL REGN No. 531

PROJECT No.

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER REVISION SHEET SIZE

A1

DESIGN WIND LOAD

ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD,

QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD

4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

1 : 50

12/0

9/20

12 9

:18:

22 A

M

A

ATCO Structures & Logistics Pty Ltd

Kitchen Diner - 48.0 x 22.5m

TK

RA

KD-500-H-C2 -05

31.05.12

Kitchen Sections

Reg. C Cat. 2 6

Rev Description Date ByA Issed for Review 04.09.12 RA

1 : 50

Section 41

1 : 50

Section 52

1 : 50

Section 63

1 : 50

Section 74

1 : 50

Section 85 1 : 50

Section 96

1 : 50

Section 107 1 : 50

Section 118

THIS DRAWING REMAINS THE PROPERTY OF ATCOSTRUCTURES PTY. LTD. IT MAY NOT BE REPRODUCED

OR COPIED WHOLE OR IN PART WITHOUT WRITTENAUTHORITY

© COPYRIGHT

QUALITY CERTIFIED TO AS/NZS ISO 9001:2008BY

SCI-QUAL INTERNATIONAL REGN No. 531

PROJECT No.

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER REVISION SHEET SIZE

A1

DESIGN WIND LOAD

ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD,

QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD

4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

12/0

9/20

12 9

:18:

24 A

M

A

ATCO Structures & Logistics Pty Ltd

Kitchen Diner - 48.0 x 22.5m

TK

RA

KD-500-H-C2 -07

31.05.12

Sales Schedules

Reg. C Cat. 2 6

Sales Window Schedule

No. Type Glazing Height WidthSill

Height Quantity CommentsO1 Window Opening only Dish Return 1200 1000 900 1O2 Window Opening only Servery Window 1200 4200 880 1W1 Sliding XO Grey Glass 900 1208 1000 19W2 Sliding XO1 Obscure Glass 600 1208 1300 3 45° SillW3 Sliding XO.. Obscure Glass 350 1200 1550 1 45° Sill

Sales Roof Structure ScheduleRoof Structure Comments

2° End to End RoofC2 - SDEK/PBD LC10015 - 400 - (3.0 & 3.5)Ceiling Joist Centres - Kitchen 400mm - Diner 611mmCeiling Joist - LC10015 GalvaspanInsulation - R2.3 Foil Backed Blanket - 95mmLining - Internal - 3.6mm Mirage Pearl PlywoodLining - Internal - 6mm Villaboard Kitchen Area.

Loading DockCeiling.

Purlins - C7510 / LC7512 GalvaspanRoof - 0.42mm BMT Superdek Roofing DINER ONLYRoof - 0.48mm BMT Superdek Roofing KITCHEN

ONLY

- Wall ScheduleWall Structure Comments

Coldroom / Freezer WallsPanel0.6mm Colorbond Skin100mm EPS Panel Coldroom150mm EPS Panel FreezerExternal WallStud Centres - Diner 611mm - Kitchen 400mmCladding External - Colorbond Maxirib -"Headland"

Lower firstsheet

Cladding External - Colorbond Maxirib -"Paperbark"

Upper Sheets

Framing - 75 x 1.0mm Hi-Ten TruecoreInsulation - R2.9 Batts - 75mmInsulation - Sisalation Kitchen

External WallsLining - 6mm Villaboard Kitchen AreaLining - Internal - 3.6mm Polyester CoatedPlywood

Diner

Thermal Break between Framing and CladdingExternal Wall / Double600mm Stud CentresCladding External - Colorbond Maxirib -"Headland"

Lower firstsheet

Cladding External - Colorbond Maxirib -"Paperbark"

Upper Sheets

Framing - 2 Walls - 75 x 1.0mm Hi-TenTruecoreInsulation - R2.9 Batts - 75mmLining - 6mm Villaboard Kitchen AreaThermal Break between Framing and CladdingVillaboard Double Internal Wall400mm Stud CentresFraming - 2 Walls - 75 x 1.0mm Hi-TenTruecoreLining - 6mm Villaboard Kitchen AreaVillaboard Internal Wall400mm Stud CentresFraming - 75 x 1.0mm Hi-Ten TruecoreLining - 6mm Villaboard Kitchen Area

* Plumbing FixturesNo. Description Quantity Comments

Plumbing - Water Inlet c/w Line Strainer 14 BIRKO 15ltr Autoboiler 220 Hand Basin, Stainless Steel - Knee Operated (Hot &

Cold)3

24 600 x 450 x 380 deep Sink c/w Pot Wash Item 40 3 Hot & Cold24a 600 x 450 x 380 deep Sink c/w Flickmixer 1 Hot & Cold25 450 x 450 x 300 deep Sink c/w Flickmixer 3 Hot & Cold28 4 Tap Stainless Steel Wash Trough 1800mm long 329 Cleaners sink with hinged grate (Hot & Cold Tap Only) 140 Pot Wash - Hob Mounted Pre Rinse & Add On Pot Filler 2 Hot & Colddp Dropper only, for 100 x 75mm Downpipe 36fw Commercial Floor Waste 15HC Hose Cock 2

HWS 315Ltr Triple element hot water system - mountedexternally

2

Lighting Fixtures Quantity1x36W Fluro - IP65 102x36W Fluro & Diffuser 68Exit - Ceiling Mount 4Exit - Ceiling Mount Directional 2Exit - Wall Mount 1Single Vandalite - Wall Mounted 1Spitfire 10W - Emegency Light - Battery Backup 9Switch - IPX5 2Switch - Std 14

- Electrical FixturesDescription Quantity

1x10amp GPO 71x10amp GPO - Ceiling Mounted 51x10amp GPO - Floor Mounted 101x10amp GPO - Suspended 21x15amp GPO 81x15amp GPO - Suspended 21x15amp GPO AC 91x20amp 3Ø Point 12x10amp GPO 25Emergency Stop 2Emergency Stop on Canopy 2Energy Efficiency and Emergency Lighting Control Panel(HAGER)

2

Isolation Switch - AC 25Isolation Switch - HWS 2Mains Switchboard 5On-Off Switch 4Photo Electric Cell 3POE 5Switchboard 12

- Furniture

No. DescriptionManufactur

er Quantity17a Shelving 4 Tier Post Style with Wire Grid Shelves 1800h x

1800w x 600dMANTOVA 8

17b Shelving 4 Tier Post Style with Wire Grid Shelves 1800h x1500w x 600d

MANTOVA 2

17c Shelving 4 Tier Post Style with Wire Grid Shelves 1800h x1200w x 600d

MANTOVA 4

18a Shelving 4 Tier Post Style with ABS Shelves - 1800h x1500w x 600d

MANTOVA 16

18b Shelving 4 Tier Post Style with ABS Shelves - 1800h x1200w x 600d

MANTOVA 4

18c Shelving 4 Tier Post Style with ABS Shelves - 1800h x1350w x 600d

MANTOVA 4

18d Shelving 4 Tier Post Style with ABS Shelves - 1800h x750w x 600d

MANTOVA 3

18e Shelving 3 Tier Post Style with ABS Shelves - 1200h x1200w x 600d

MANTOVA 1

18f Shelving 3 Tier Post Style with ABS Shelves - 1200h x600w x 600d

MANTOVA 1

18g Shelving 4 Tier Post Style with ABS Shelves - 1800h x1200w x 600d

MANTOVA 3

26 Tubular Tray Race x 4200w 127 Pot Rack 4 Tier Post Style with Wire Grid Shelves 1800h x

1200w x 600dMANTOVA 1

30 Steel Framed Stacker Chair 30031 1800 x 750 Melamine lunch table 50

Sales Mechanical EquipmentNo. Supplier Description QuantityM1 TECO 900mm Air Curtains 8M2 DAIKIN 3.5kW R/C Split System Air Conditioner -

Inverter2

M3 DAIKIN 5.0kW R/C Split System Air Conditioner -Inverter

17

M4 DAIKIN 7.1kW R/C Split System Air Conditioner -Inverter

6

M5 Aircon Eng. Fresh Air Dual Kitchen Induction System 1M6 T&H Sheetmetal Exhaust Canopy - Main x 6300w 1M7 T&H Sheetmetal Exhaust Canopy - Secondary x 5400 1M8 T&H Sheetmetal Vent Hood for ES100 Rack - Conveyor

Dishwasher1

M9 External Compressors - Freezer / Chiller 1M10 External Compressor - Freezer 2M11 External Compressor - Chiller 2

- Floor Structure ScheduleFloor Structure Comments

DECK400mm Floor Joist CentresFlooring - 19 x 89mm ShotedgeFraming - LC7512 Galvaspan

DINER FLOOR480mm Floor Joist CentresCovering - 2.0mm Polyflor XL VinylFlooring - 17mm F11 T&G PlywoodJoists - LC10015 Galvaspan

KITCHEN FLOOR400mm Floor Joist CentresCovering - 2.0mm Polyflor Non-Slip Vinyl 100mm CoveFlooring - 15mm Compressed Fibre Cement(CFC)Joists - LC10015 Galvaspan

Wall Height2445

- Electrical Equipment ScheduleNo. Description Manufacturer Model Quantity

1 Salad Bar - 6 Mod - Storage Under / Glass Canopy BRAMS 6 Mod 82 Drinks Dispenser - 4 x 12 Litre PROMAC VL 448 43 Conveyor Toaster ROBAND TCR15 45 Rack - Conveyor Dishwasher ESWOOD ES100 18 Combi Oven - Electric BLUESEAL 20 tray - E20CSDW 18a Combi Oven - Electric BLUESEAL 14 tray - E14CSDW 19 Tilting Bratt Pan - Electric - 150 Litre GOLDSTEIN TPE-150 110 Deep Fryer - Electric - 3 Pan x 21 Litre GOLDSTEIN FRE-72D 111 Griddle - Electric GOLDSTEIN GPEDB-36 & SB36 212 Range - Electric - 8 Element GOLDSTEIN PE-8R-28 213 Hot Bain Marie - 6 Mod - Heated Storage Under / Sneeze Guard BRAMS 6 Mod 219a Planetary Mixer - 40 litre PARAMOUNT BM40 119b Planetary Mixer - 20 litre PARAMOUNT BM20 121 Semi Automatic Slicer BRICE GL Matic 122 Two Glass Door Chiller - 1120 Litres SKOPE B1200-2 322a Single Glass Door Chiller - 600 Litres SKOPE B600-2 232 Potato Peeler SAMMIC M10 136 Ice Cream Freezer - 183 Litre BAKER GLOBO 241 Microwave BONN MV 1000 1

BUG Electronic Bug Killer - 2 x 20W INSECT-O-CUTOR 14614 5

- Fire Services ScheduleNo. Description Quantity34 9.0Kg Fire Extinguisher - AB(E) 335 Fire Blanket 3

Handrail ScheduleTwin Rail Horizontal Handrails - as shown on floor plan

Manufacturing Structural Members

Description Member SizeBack to

BackSkid Beams - Perimeter Chasis 200PFC 2850Skid beams c/w retractablelifters

200PFC 2000

Rail System 200UB22.3Paired Beams C20020Paired Beams C30030 Stiffened

& Cambered

Rainwater GoodsDescription Quantity

Dropper only, for 100 x 75mm Downpipe 36

Sales Door Schedule

No. Panel Height WidthHandleType Hardware Set Closer

PanicBar

C/BJamb

TimberJamb Security Quantity Comments

D1 Standard : Hollow Core MC 2040 1840 Lever Entrance Yes No Yes No 3 E/E SealsD2 Standard : Hollow Core MC 2040 1740 Lever Entrance Yes No Yes No 1 E/E SealsD3 Standard : Hollow Core MC 2040 820 Standard Entrance No No Yes No 1 E/E SealsD4 Half Glass : Solid Core 2040 920 Lever Passage Yes No No Yes 2D5 Half Glass : Hollow Core 2040 920 Lever Entrance No No No Yes 2D6 Standard : Coldroom Panel Door 1900 800 Coolroom Furniture Yes No 3 Chillers - Supplied and installed by third party.D7 Standard : Freezer Panel Door 1900 800 Coolroom Furniture Yes No 3 Freezer - Supplied and installed by third party.O3 Opening Only 2040 1837 Yes No 3

Rev Description Date ByA Issed for Review 04.09.12 RA

FREEZER FLOOR - 100mm panel type c/w 15mm CFC,epoxy coated to give a water resistant surface with 3mmAli. Checker Plate over.COLDROOM FLOOR - 100mm panel type c/w 15mm CFC,epoxy coated to give a water resistant surface with 3mmAli. Checker Plate over.

NOTE: Floors flush to Hallway FFL

Stainless Steel BenchesNo. Description Quantity6a Dish Return c/w Scraps Hole / Chute (1400 x 2825 x 2900) (300 high

Splashback with 600 high wall cover)1

6b Dishwash Exit - 1500 x 700 (300 high Splashback with 600 high wallcover)

1

7a Prep Bench - Meat 01 x 2700w (300 high Splashback) 17b Prep Bench - Meat 02 x 4200w (300 high Splashback) 17c Prep Bench - Bakery 01 x 3200w (300 high Splashback) 17h Mobile Bench - Meat x 1200w (No Splashback) 17j Mobile Bench - Vege x 1200w (No Splashback) 114 Mobile Bench - Diner x 1800w x 750d x 900h (No Splashback) 515a Beverage Bench x 2850w (600 high Splashback) Splashback to LH side 115b Beverage Bench x 2900w (600 high Splashback) 116 Prep Bench - Cooking x 2900w (300 high Splashback) 116a Prep Bench - Cooking - Shelf x 2900w 133 Infill Bench - 450w 750d (300 high Splashback) 1

ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

CarmichaelQLD

Adani Mining Pty. Ltd.120842G

12.0 x 6.0m Office

- Drawing ListSheet

Number Sheet NameCurrentRevision

00 Title Page01 Floor Plan02 Elevations06 Sales Schedules

2

PE

DSB

POE

22 2

2

2

22 2 dpdp

dpdp

2

103

203

A

1 2

B

x

D12040

920

x

W11208900

300

AFFL

300

AFFL

1200

AFF

L

FE

82 2875 86 8875 82

8228

3616

428

3682

12000

6000

C

C30030 Paired Beams

x

D22040

920

x

D22040

920

x

W11208900

x

W11208900

x

W11208900

x

W11208900x

W11208900 x

W11208900

M1

M1

M2

M2

300 AFFL

300 AFFL

300 AFFL

300 AFFL

300

AFFL

300 AFFL

OFFICE

RECEPTIONOFFICE

OPEN OFFICE

4 4 4 4 4 4

1

2

3 3

1

4

2

3 3

1

2

1

2

4

2

1

33

3 3

2

1 1

2

2

1

300

AFFL

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

CarmichaelQLD

1 : 50

22/0

8/20

12 2

:05:

21 P

M

Adani Mining Pty. Ltd.12.0 x 6.0m Office

TK

RA

120842G -01

21.08.12

Floor Plan C2

5

Notes

1 : 50

Floor Plan1

Item ListD1 2040 x 920 External Door - Standard : Hollow Core MCD2 2040 x 920 Internal Door - Standard : Hollow Core

W1 900 x 1208 Sliding Glass Window - Grey Glass

M1 2.66kW R/C Split System Air ConditionerM2 5.05kW R/C Split System Air Conditioner

Rev Description Date By

1 Swivel Chair2 1200 x 600 Desk c/w Drawer3 PVC Stacker chair4 4 Drawer Filing Cabinet - By Othersdp Dropper only, for 100 x 75mm DownpipeFE Fire Extinguisher 9.0kg - AB(E)

- Fire fighting equipment supplied & installed by others.

- Plans are current at time of issue, are indicative only, and are subject tochange at any time without notice.

EXIT

240V Smoke detector

Distribution Switchboard

External light18W Single Vandalite

36w Single fluorescent light

15amp Single GPO.10amp Double GPO10amp Single GPO

36w Single fluorescent light - IP65 rated

36w Double fluorescent light

10amp GPO - IPX5 rated

Comms. - Draw wire only

Light switchTwo-way light switch

Photo electric light switchSpot light

'F' Type television outlet

Oyster light

Light switch - IPX5 rated

20amp Single GPO

Emergency exit lightOyster Light - 11W Round Fluro

36w Emergency back-up fluorescent light

POE - Point Of Entry

- Indicates floor mounting- Indicates ceiling mounting

DSB

IPX5

IPX5

WP

PE

Symbol Legend

2

Isolation Switch

PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point

ALL FURNITURE OPTIONED

FFL

0

Ceiling

2445

GL

-600

12

FFL

0

Ceiling

2445

GL

-600

1 2A B C

ABC

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

CarmichaelQLD

1 : 75

22/0

8/20

12 2

:05:

30 P

M

Adani Mining Pty. Ltd.12.0 x 6.0m Office

TK

RA

120842G -02

21.08.12

Elevations C2

5

1 : 75

Elevation AA

1 : 75

Elevation BB

Rev Description Date By

1 : 75

Elevation D1

1 : 75

Elevation C2

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

CarmichaelQLD

22/0

8/20

12 2

:05:

31 P

M

Adani Mining Pty. Ltd.12.0 x 6.0m Office

TK

RA

120842G -06

21.08.12

Sales Schedules C2

5

Sales Window Schedule

No. Type Glazing Height WidthSill

Height Quantity CommentsW1 Sliding XO Grey Glass 900 1208 1200 7 c/w Curtains

Sales Roof Structure ScheduleRoof Structure Comments

2° End to End RoofC2 - SDEK/PLY LC7512 - 611 - (3.0 & 3.5)611mm Ceiling Joist CentresCeiling Joist - LC7512 GalvaspanInsulation - R2.3 Foil Backed Blanket - 95mmLining - Internal - 3.6mm Polyester CoatedPlywoodPurlins - C7510 / LC7512 GalvaspanRoof - 0.42mm BMT Superdek Roofing

- Wall ScheduleWall Structure Comments

External Wall611mm Stud CentresCladding External - Colorbond Maxirib -"Headland"

Lower firstsheet

Cladding External - Colorbond Maxirib -"Paperbark"

Upper Sheets

Framing - 75 x 1.0mm Hi-Ten TruecoreFraming - 75x1.0mm Hi-Ten SteelInsulation - R2.9 Batts - 75mmLining - Internal - 3.6mm Polyester CoatedPlywoodThermal Break between Framing and CladdingPly Internal Wall611mm Stud CentresFraming - 75 x 1.0mm Hi-Ten TruecoreLining - Internal - 3.6mm Polyester CoatedPlywood

* Plumbing FixturesNo. Description Quantity Commentsdp Dropper only, for 100 x 75mm Downpipe 4

Lighting Fixtures Quantity2x36W Fluro - Bare 8Single Vandalite - Wall Mounted 1Switch - Std 1

- Electrical FixturesDescription Quantity

1x15amp GPO AC 42x10amp GPO 10Photo Electric Cell 1Switchboard 1- Furniture

No. Description Quantity Comments1 Swivel Chair 82 1200 x 600 Desk c/w Drawer 83 PVC Stacker chair 84 4 Drawer Filing Cabinet - By Others 8

Sales Mechanical EquipmentNo. Supplier Description QuantityM1 TECO 2.66kW R/C Split System Air Conditioner 2M2 TECO 5.05kW R/C Split System Air Conditioner 2

- Floor Structure ScheduleFloor Structure Comments

Floor600mm Floor Joist CentresCovering - 1.5mm Polyflor XL VinylFlooring - 17mm F11 T&G PlywoodInsulation - Under Floor - 15mm FoilboardJoists - LC7512 Galvaspan

Wall Height2445

- Fire Services ScheduleNo. Description QuantityFE 9.0Kg Fire Extinguisher - AB(E) 1

Manufacturing Structural Members

DescriptionMember

SizeBack to

BackSkid Beams c/w RetractableLifters

150PFC 2000

Paired Beams C30030

Sales Door Schedule

No. Panel Height WidthHandleType

HardwareSet Closer

PanicBar

C/BJamb

TimberJamb Security Quantity Comments

D1 Standard : Hollow Core MC 2040 920 Lever Entrance Yes No Yes No 1 E/E SealsD2 Standard : Hollow Core 2040 920 Lever Entrance No No Yes No 2

Rev Description Date By

ALL FURNITURE OPTIONED

OPTION

ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

Carmichael ProjectQLD

Adani Mining Pty. Ltd.120842H

12.0 x 3.0m Ablution Block

- Drawing ListSheet

Number Sheet NameCurrentRevision

00 Title Page01 Floor Plan02 Elevations05 Sales Schedules

View indicative only

DSB

PO

EPE

dp dpdp

WP WPfw fw

fw

103

203

A

1 2

Bx

D12040

820

6350 86 5400

1400

AFF

L

6

82 11837 82

8228

3782

12000

3000

HWS

2211

3 3

x

D22040

820

2 21 1

33

4

1439 86 900 62 870 62 870 86 945 86 945 945 86 945 86 870 62 870 62 1475

1337

1500

937

1900

5

5

5

5

5

x

W1750350x

W1750350 x

W1750350 x

W1750350x

W1750350 x

W1750350

x

W1750350 x

W1750350

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

Carmichael ProjectQLD

1 : 50

22/0

8/20

12 1

:28:

41 P

M

Adani Mining Pty. Ltd.12.0 x 3.0m Ablution Block

TK

RA

120842H -01

21.08.12

Floor Plan C2

10a

- Fire fighting equipment supplied & installed by others.- Plans are current at time of issue, are indicative only, and are subject to

change at any time without notice.

Notes1 WC Cubicle c/w toilet roll holder2 Shower enclosure c/w bench seat & coat hooks3 S/S Handbasin c/w mirror over4 600mm Wall mounted S/S urinal5 Locker - 4 Bank 300 Wide - 1 Tier6 9.0Kg Fire Extinguisher - AB(E)dp Dropper only, for 100 x 75mm Downpipefw Floor WasteHWS Rheem Heat Pump 325 Litre/6kW -MPi - mounted externallyItem List

D1 2040 x 820 External Door - Standard : Hollow Core MCD2 2040 x 820 External Door - Standard : Hollow Core MCW1 350 x 750 Sliding Glass Window - Obscure Glass

Rev Description Date By

240V Smoke detector

Distribution Switchboard

External light18W Single Vandalite

36w Single fluorescent light

15amp Single GPO.10amp Double GPO10amp Single GPO

36w Single fluorescent light - IP65 rated

36w Double fluorescent light

10amp GPO - IPX5 rated

Comms. - Draw wire only

Light switchTwo-way light switch

Photo electric light switch

Spot light

'F' Type television outlet

Oyster light

Light switch - IPX5 rated

20amp Single GPO

Emergency exit light

Oyster Light - 11W Round Fluro

36w Emergency back-up fluorescent light

POE - Point Of Entry

- Indicates floor mounting- Indicates ceiling mounting

IPX5

IPX5

WP

Symbol Legend

Isolation Switch

PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point

OPTIONAL

FFL

0

Ceiling

2445

GL

-600

12

FFL

0

Ceiling

2445

GL

-600

1 2A B

AB

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

Carmichael ProjectQLD

1 : 75

22/0

8/20

12 1

:28:

49 P

M

Adani Mining Pty. Ltd.12.0 x 3.0m Ablution Block

TK

RA

120842H -02

21.08.12

Elevations C2

10a

1 : 75

Elevation AA

1 : 75

Elevation BB

2° End to End Roof

Aluminium Framed Windows

Panelrib External Cladding

Metal Clad External Doors

150 PFC Skid Beams

Rev Description Date By

1 : 75

Elevation D1

1 : 75

Elevation C2

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

Carmichael ProjectQLD

22/0

8/20

12 1

:28:

53 P

M

Adani Mining Pty. Ltd.12.0 x 3.0m Ablution Block

TK

RA

120842H -05

21.08.12

Sales Schedules C2

10a

Sales Window Schedule

No. Type Glazing Height WidthSill

Height Quantity CommentsW1 PVO Obscure Glass 350 750 1960 8

Sales Roof Structure ScheduleRoof Structure Comments

2° End to End RoofC2 - SDEK/PLY LC7512 - 611 - (3.0 & 3.5)611mm Ceiling Joist CentresCeiling Joist - LC7512 GalvaspanInsulation - R2.3 Foil Backed Blanket - 95mmLining - Internal - 3.6mm Polyester CoatedPlywoodPurlins - C7510 / LC7512 GalvaspanRoof - 0.42mm BMT Superdek Roofing

- Wall ScheduleWall Structure Comments

External Wall611mm Stud CentresCladding External - Colorbond Maxirib -"Headland"

Lower firstsheet

Cladding External - Colorbond Maxirib -"Paperbark"

Upper Sheets

Framing - 75 x 1.0mm Hi-Ten TruecoreLining - Internal - 3.6mm Polyester CoatedPlywoodPly Internal Wall611mm Stud CentresFraming - 75 x 1.0mm Hi-Ten TruecoreLining - Internal - 3.6mm Polyester CoatedPlywood

* Plumbing FixturesNo. Description Quantity Comments

1 WC Cubicle c/w toilet roll holder 42 Shower enclosure c/w bench seat & coat hooks 43 S/S Handbasin c/w mirror over 44 600mm Wall mounted S/S urinal 1dp Dropper only, for 100 x 75mm Downpipe 3fw Floor Waste 3

HWS Rheem Heat Pump 325 Litre/6kW -MPi -mounted externally

1

Lighting Fixtures Quantity1x36W Fluro - Bare 21x36W Fluro - IP65 2Single Vandalite - Wall Mounted 2Switch - Std 2

- Electrical FixturesDescription Quantity

1x10amp GPO 2Photo Electric Cell 1Switchboard 1

- FurnitureNo. Description Quantity Comments

5 Locker - 4 Bank 300 Wide - 1 Tier 5

- Floor Structure ScheduleFloor Structure Comments

Floor600mm Floor Joist CentresCovering - 1.5mm Polyflor XL Vinyl 100mm Cove

thoughoutFlooring - 17mm F11 T&G PlywoodJoists - LC7512 Galvaspan

Wall Height2445

- Fire Services ScheduleNo. Description Quantity

6 9.0Kg Fire Extinguisher - AB(E) 1

Manufacturing Structural Members

DescriptionMember

SizeBack to

BackSkid Beams c/w RetractableLifters

150PFC 2000

Rainwater GoodsDescription Quantity

Dropper only, for 100 x 75mm Downpipe 3

Sales Door Schedule

No. Panel Height WidthHandleType

HardwareSet Closer

PanicBar

C/BJamb

TimberJamb Security Quantity Comments

D1 Standard : Hollow Core MC 2040 820 Standard Entrance No No Yes No 1D2 Standard : Hollow Core MC 2040 820 Standard Entrance No No Yes No 1

Rev Description Date By

OPTIONAL

ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

Carmichael ProjectQLD

Adani Mining Pty. Ltd.120842J

12.0 x 3.0m Linen Store

- Drawing ListSheet

Number Sheet NameCurrentRevision

00 Title Page01 Floor Plan02 Elevations06 Sales Schedules

View indicative only

2

DSB

POE

PE

dp

dp

103

203

A

1 2

Bx

D12040

920

x

W11208900

300

AFFL

300

AFFL

1200

AFF

L

2

82 11837 82

8228

3782

12000

3000

1

1

1

1

2.8m

10.8m

4.8m

2.8m

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

Carmichael ProjectQLD

1 : 50

22/0

8/20

12 1

:13:

00 P

M

Adani Mining Pty. Ltd.12.0 x 3.0m Linen Store

TK

RA

120842J -01

20.08.12

Floor Plan C2

10a

- Fire fighting equipment supplied & installed by others.

- Plans are current at time of issue, are indicative only, and are subject tochange at any time without notice.

Notes

1 : 50

Floor Plan1

1 3 Tier shelving2 9.0Kg Fire Extinguisher - AB(E)dp Dropper only, for 100 x 75mm Downpipe

Item ListD1 2040 x 920 External Door - Standard : Hollow Core MC

W1 900 x 1208 Sliding Glass Window - Grey Glass

Rev Description Date By

EXIT

240V Smoke detector

Distribution Switchboard

External light18W Single Vandalite

36w Single fluorescent light

15amp Single GPO.10amp Double GPO10amp Single GPO

36w Single fluorescent light - IP65 rated

36w Double fluorescent light

10amp GPO - IPX5 rated

Comms. - Draw wire only

Light switchTwo-way light switch

Photo electric light switchSpot light

'F' Type television outlet

Oyster light

Light switch - IPX5 rated

20amp Single GPO

Emergency exit lightOyster Light - 11W Round Fluro

36w Emergency back-up fluorescent light

POE - Point Of Entry

- Indicates floor mounting- Indicates ceiling mounting

DSB

IPX5

IPX5

WP

PE

Symbol Legend

2

Isolation Switch

PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point

OPTION

FFL

0

Ceiling

2445

GL

-600

12

FFL

0

Ceiling

2445

GL

-600

1 2A B

AB

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

Carmichael ProjectQLD

1 : 75

22/0

8/20

12 1

:13:

05 P

M

Adani Mining Pty. Ltd.12.0 x 3.0m Linen Store

TK

RA

120842J -02

20.08.12

Elevations C2

10a

1 : 75

Elevation AA

1 : 75

Elevation BB

2° Skillion RoofAluminium Framed Windows

Panelrib External Cladding

Metal Clad External Doors

150 PFC Skid Beams

Rev Description Date By

1 : 75

Elevation D1

1 : 75

Elevation C2

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

Carmichael ProjectQLD

22/0

8/20

12 1

:13:

07 P

M

Adani Mining Pty. Ltd.12.0 x 3.0m Linen Store

TK

RA

120842J -06

20.08.12

Sales Schedules C2

10a

Sales Window Schedule

No. Type Glazing Height WidthSill

Height Quantity CommentsW1 Sliding XO Grey Glass 900 1208 1200 1 c/w Curtains

Sales Roof Structure ScheduleRoof Structure Comments

2° End to End RoofC2 - SDEK/PLY LC7512 - 611 - (3.0 & 3.5)611mm Ceiling Joist CentresCeiling Joist - LC7512 GalvaspanInsulation - R2.3 Foil Backed Blanket - 95mmLining - Internal - 3.6mm Polyester CoatedPlywoodPurlins - C7510 / LC7512 GalvaspanRoof - 0.42mm BMT Superdek Roofing

- Wall ScheduleWall Structure Comments

External Wall611mm Stud CentresCladding External - Colorbond Maxirib -"Headland"

Lower firstsheet

Cladding External - Colorbond Maxirib -"Paperbark"

Upper Sheets

Framing - 75 x 1.0mm Hi-Ten TruecoreLining - Internal - 3.6mm Polyester CoatedPlywood

* Plumbing FixturesNo. Description Quantity Commentsdp Dropper only, for 100 x 75mm Downpipe 2

Lighting Fixtures Quantity2x36W Fluro - Bare 4Single Vandalite - Wall Mounted 1Switch - Std 1

- Electrical FixturesDescription Quantity

1x10amp GPO 12x10amp GPO 1Photo Electric Cell 1Switchboard 1

- FurnitureNo. Description Quantity Comments

1 3 Tier shelving 4

- Floor Structure ScheduleFloor Structure Comments

Floor600mm Floor Joist CentresCovering - 1.5mm Polyflor XL Vinyl 100mm Cove

thoughoutFlooring - 17mm F11 T&G PlywoodJoists - LC7512 Galvaspan

Wall Height2445

- Fire Services ScheduleNo. Description Quantity

2 9.0Kg Fire Extinguisher - AB(E) 1

Manufacturing Structural Members

DescriptionMember

SizeBack to

BackSkid Beams c/w RetractableLifters

150PFC 2000

Sales Door Schedule

No. Panel Height WidthHandleType

HardwareSet Closer

PanicBar

C/BJamb

TimberJamb Security Quantity Comments

D1 Standard : Hollow Core MC 2040 920 Lever Entrance No No Yes No 1 E/E Seals

Rev Description Date By

OPTION

OPTION

ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

QLDATCO Structures & Logistics Pty. Ltd.

WGM-1212-H-C2

12.0 x 12.0m Gymnasium

- Drawing ListSheet

Number Sheet NameCurrentRevision

00 Title Page01 Floor Plan02 Elevations06 Sales Schedules

DSB

POEPE

DSB

PO

E

DSB

PO

E

DSB

PO

E

DSB

PO

E 2

22

22

22

2

TV

dpdp

dpdpdp

dpdp

dp

103

203

A

1 2

B

x

D12040

1840 300

AFFL

1200

AFF

L

1

82 11837 8282

1183

782

1200012

000

C

C20020 Paired Beams

D

E

Post

Post

Post

x

W11208900

x

W11208900

x

W11208900

M1

M1

x

W11208900

x

W11208900

M1

M1

x

W11208900

x

W11208900

M1

M1

x

W11208900

x

W11208900

M1

M1

x

W11208900 x

W11208900

x

W11208900 x

W11208900

300 AFFL

300 AFFL

300 AFFL

300 AFFL

300 AFFL

300 AFFL

300 AFFL

300 AFFL

300

AFFL

2 2

Wat

er S

uppl

y

Wat

er S

uppl

y

33 3

3

3

3

MIRRORunder A/C

MIRRORunder A/C

MIRRORunder A/C

MIRRORunder A/C

4

4

4

57

8

9

10

6

9

12

11

13

8

9 14

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

QLD1 : 75

2/08

/201

2 2:

08:2

6 P

M

ATCO Structures & Logistics Pty. Ltd.12.0 x 12.0m Gymnasium

TK

RA

WGM-1212-H-C2 -01

14.04.12

Floor Plan C2

9b

Notes

Item ListD1 2040 x 1840 External Double Door - Standard : Hollow Core MC

W1 900 x 1208 Sliding Glass Window - Grey Glass

M1 5.0kW R/C Split System Air Conditioner - Inverter

Rev Description Date By

- Fire fighting equipment supplied & installed by others.

- Plans are current at time of issue, are indicative only and are subject tochange at any time without notice.

Vision 9700 HRC Tread Mill4 3

Olympic Bench Press Prone5 1

Vision 6850 XT Cross Trainer6 1

Smith Machine Linear7 1

Adjustable Incline Bench 0-90°8 2

Vision 3800 U/R Exercise Bike9 3

Concept 2 Model D Rowing machine10 1

Elite Sschwinn 780 Multistation11 1

Abdominal Ladder12 1

Heavy Bag & Speed Ball & Stand13 1

1 to 25kg Dumbell Set & Rack14 1

Items not shown, but included:Olympic EZ Curl Bar & WeightsOlympic 7' Straight Bars & CollarsLeather Weight Lifting Belt200kg of Olympic Weights &Weight Tree

Equipment

Plumbing - Water Inlet c/w Line Strainer1 9.0Kg Fire Extinguisher - AB(E)2 Water Cooler - Zip Freestanding EMBCF 60 - Mains Connected3 1800 x 900 Mirrordp Dropper only, for 100 x 75mm Downpipe

EXIT

240V Smoke detector

Distribution Switchboard

External light18W Single Vandalite

36w Single fluorescent light

15amp Single GPO.10amp Double GPO10amp Single GPO

36w Single fluorescent light - IP65 rated

36w Double fluorescent light

10amp GPO - IPX5 rated

Comms. - Draw wire only

Light switchTwo-way light switch

Photo electric light switchSpot light

'F' Type television outlet

Oyster light

Light switch - IPX5 rated

20amp Single GPO

Emergency exit lightOyster Light - 11W Round Fluro

36w Emergency back-up fluorescent light

POE - Point Of Entry

- Indicates floor mounting- Indicates ceiling mounting

DSB

IPX5

IPX5

WP

PE

Symbol Legend

2

Isolation Switch

PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point

FFL

0

Ceiling

2745

GL

-600

12

FFL

0

Ceiling

2745

GL

-600

1 2A B C D E

ABCDE

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

QLD1 : 75

2/08

/201

2 2:

08:3

6 P

M

ATCO Structures & Logistics Pty. Ltd.12.0 x 12.0m Gymnasium

TK

RA

WGM-1212-H-C2 -02

14.04.12

Elevations C2

9b

1 : 75

Elevation AA

1 : 75

Elevation BB

Rev Description Date By

1 : 75

Elevation D1

1 : 75

Elevation C2

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

QLD

2/08

/201

2 2:

08:3

7 P

M

ATCO Structures & Logistics Pty. Ltd.12.0 x 12.0m Gymnasium

TK

RA

WGM-1212-H-C2 -06

14.04.12

Sales Schedules C2

9b

Sales Window Schedule

No. Type Glazing Height WidthSill

Height Quantity CommentsW1 Sliding XO Grey Glass 900 1208 1000 13 c/w Curtains

* Plumbing FixturesNo. Description Quantity Comments

Plumbing - Water Inlet c/w Line Strainer 12 Water Cooler - Zip Freestanding EMBCF 60 -

Mains Connected2

dp Dropper only, for 100 x 75mm Downpipe 8

Lighting Fixtures Quantity2x36W Fluro - Bare 17Single Vandalite - Wall Mounted 1Switch - Std 1

- Electrical FixturesDescription Quantity

1x10amp GPO - Ceiling Mounted 11x10amp GPO AC 22x10amp GPO 8Isolation Switch - AC 8Photo Electric Cell 1Switchboard 5TV - Ceiling Mtd 1

- FurnitureNo. Description Quantity Comments

3 1800 x 900 Mirror 6

Sales Mechanical EquipmentNo. Supplier Description QuantityM1 DAIKIN 5.0kW R/C Split System Air Conditioner -

Inverter8

- Floor Structure ScheduleFloor Structure Comments

Floor300mm Floor Joist CentresCovering - Planet Supreme Direct Stick CarpetFlooring - 17mm F11 T&G Plywood Two LayersJoists - LC7512 Galvaspan

Wall Height2745

- Fire Services ScheduleNo. Description Quantity

1 9.0Kg Fire Extinguisher - AB(E) 1

Manufacturing Structural Members

DescriptionMember

SizeBack to

BackSkid Beams c/w RetractableLifters

150PFC 2000

Paired Beams C20020

Sales Door Schedule

No. Panel Height WidthHandleType

HardwareSet Closer

PanicBar

C/BJamb

TimberJamb Security Quantity Comments

D1 Standard : Hollow Core MC 2040 1840 Lever Entrance Yes No Yes No 1 E/E Seals and Closerto each leaf.

Rev Description Date By

Vision 9700 HRC Tread Mill4 3

Olympic Bench Press Prone5 1

Vision 6850 XT Cross Trainer6 1

Smith Machine Linear7 1

Adjustable Incline Bench 0-90°8 2

Vision 3800 U/R Exercise Bike9 3

Concept 2 Model D Rowing machine10 1

Elite Sschwinn 780 Multistation11 1

Abdominal Ladder12 1

Heavy Bag & Speed Ball & Stand13 1

1 to 25kg Dumbell Set & Rack14 1

Items not shown, but included:Olympic EZ Curl Bar & WeightsOlympic 7' Straight Bars & CollarsLeather Weight Lifting Belt200kg of Olympic Weights &Weight Tree

Equipment

- Wall ScheduleWall Structure Comments

External Wall611mm Stud CentresCladding External - Colorbond Maxirib -"Headland"

Lower firstsheet

Cladding External - Colorbond Maxirib -"Paperbark"

Upper Sheets

Framing - 75 x 1.0mm Hi-Ten TruecoreFraming - 75x1.0mm Hi-Ten SteelInsulation - R2.9 Batts - 75mmLining - Internal - 3.6mm Polyester CoatedPlywoodThermal Break between Framing and Cladding

Sales Roof Structure ScheduleRoof Structure Comments

2° End to End RoofC2 - SDEK/PLY LC7512 - 611 - (3.0 & 3.5)611mm Ceiling Joist CentresCeiling Joist - LC7512 GalvaspanInsulation - R2.3 Foil Backed Blanket - 95mmLining - Internal - 3.6mm Polyester CoatedPlywoodPurlins - C7510 / LC7512 GalvaspanRoof - 0.42mm BMT Superdek Roofing

ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

QLDATCO Structures & Logistics Pty. Ltd.

WRC-1812-H-C2

18.0 x 12.0m Recreation Centre

- Drawing ListSheet

Number Sheet NameCurrentRevision

00 Title Page01 Floor Plan02 Elevations06 Sales Schedules

fw

fw

DSB

POE

DSB

POE

DSB

POE

DSB

POE

DSB

POE

DSB

POE

22

22

2

2

22

22

2

22

2 2

2 2 2 2

2

2TV

EXI

T

EXIT

EXIT

fw

dp dp dp dp dp dp

dp dp dp dp dp dpPEPE PE

103

203

A

1 5

82 17837 82

8211

837

82

18000

1200

0

2 3 4 76

B

x

W11208900

x

W11208900

x

W11208900

x

W11208900

M1

M1

C20

020

Pai

red

Bea

ms

C20

020

Pai

red

Bea

ms

C20

020

Pai

red

Bea

ms

C20

020

Pai

red

Bea

ms

Post Post Post

x

W11208900 x

W11208900 x

W11208900 x

W11208900

M1 M1 M1 M1

M1

x

W11208900

M1

x

W21208900

M1

M1

x

W11208900

x

W21208900

x

D12040

1840

x

D22040

920

x

D22040

920

x

D22040

920

x

D42040

920

x

D32040

920

x

RW11208900

x

RW11208900

x

RW11208900

12

12M1

11

10a

10b

8

811

7

1920

5

5

5

5

5

15 15

4

1

4

44

4

4

4

4

4

4 214

14

M1

22

1200 AFFL

300 AFFL

1400 AFFL22

00 A

FFL

1200

AFF

L

300

AFFL

1400 AFFL

300

AFFL

1700 AFFL

1200 AFFL

1400 AFFL

300

AFFL

1200

AFF

L

1400 AFFL

1400 AFFL

1400 AFFL

300

AFFL

300

AFFL

1200

AFF

L1400 AFFL

1400 AFFL

1700 AFFL

1400 AFFL

1400 AFFL

1400 AFFL

1400 AFFL

1400 AFFL1400 AFFL

2200 AFFL

1400 AFFL300 AFFL

300

AFFL

2

2

55

5 5TYPICAL

13

9

18

6

300 AFFL

3

3

x

D12040

1840

2222

2222

Stacked A/C Motors

17

1400 AFFL1400 AFFL

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

QLD 1 : 100

2/08

/201

2 1:

53:2

3 P

M

ATCO Structures & Logistics Pty. Ltd.18.0 x 12.0m Recreation Centre

TK

RA

WRC-1812-H-C2 -01

14.04.12

Floor Plan C2

9b

Notes

1 : 100

Floor Plan1

Plumbing - Water Inlet c/w Line Strainer1 Television - LCD - 50" - 127cm2 9.0Kg Fire Extinguisher - AB(E)3 MANITOWOC - Ice Machine - S-450 on B400 Storage

Bin (173kg/24hr, 130kg holding capacity)4 Lounge Chair5 PVC Stacker chair6 1200 Dia. Melamine table7 Fridge - Single Door - 370 Litre - WRM3700WB8 1200x450 S/S insert sink9 7.5ltr Autoboiler

10a 600mm Wide Laminated benchtop c/w cupboards x2400. c/w 600 high SS Splashback

10b 600mm Wide Laminated benchtop c/w cupboards x1800. c/w 600 high SS Splashback

11 50Ltr Hot Water System - Internal c/w Safe Tray12 SKOPE Two Glass Door Chiller - B900-213 600mm Wide Laminated benchtop c/w cupboards & 2

sets of drawers.14 Dart Board15 Pool table c/w Cue Rack & pool Cues17 5 Tap Stainless Steel Fill Up Station - 3000mm long18 600mm (W) Melamine benchtop c/w steel legs19 Dishwasher20 Water Cooler - Zip Freestanding EMBCF 60 - Mains

Connected. SS Splashback.22 Wall mounted water connectiondp Dropper only, for 100 x 75mm Downpipefw Floor Waste

Item ListD1 2040 x 1840 External Double Door - Standard : Hollow Core MCD2 2040 x 920 External Door - Standard : Hollow Core MCD3 2040 x 920 Internal Door - Standard : Hollow CoreD4 2040 x 920 Internal Door - Standard : Hollow Core

RW1 900 x 1208 Roller Window ColorbondW1 900 x 1208 Sliding Glass Window - Grey GlassW2 900 x 1208 Sliding Glass Window - Grey Glass

M1 5.0kW R/C Split System Air Conditioner - Inverter

Rev Description Date By

- Fire fighting equipment supplied & installed by others.

- Plans are current at time of issue, are indicative only and are subject to changeat any time without notice.

- Any 3D views are to be regarded as indicative only.- Additional Draw Wires may be required subject to Client requirement

240V Smoke detector

Distribution Switchboard

External light18W Single Vandalite

36w Single fluorescent light

15amp Single GPO.10amp Double GPO10amp Single GPO

36w Single fluorescent light - IP65 rated

36w Double fluorescent light

10amp GPO - IPX5 rated

Comms. - Draw wire only

Light switchTwo-way light switch

Photo electric light switch

Spot light

'F' Type television outlet

Oyster light

Light switch - IPX5 rated

20amp Single GPO

Emergency exit light

Oyster Light - 11W Round Fluro

36w Emergency back-up fluorescent light

POE - Point Of Entry

- Indicates floor mounting- Indicates ceiling mounting

DSB

IPX5

IPX5

WP

EXIT

PE

Symbol Legend

2

Isolation Switch

PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point

FFL

0

Ceiling

2445

GL

-600

15 2347 6

FFL

0

Ceiling

2445

GL

-600

1 52 3 4 76A B

AB

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

QLD 1 : 100

2/08

/201

2 1:

53:4

5 P

M

ATCO Structures & Logistics Pty. Ltd.18.0 x 12.0m Recreation Centre

TK

RA

WRC-1812-H-C2 -02

14.04.12

Elevations C2

9b

1 : 100

Elevation AA

1 : 100

Elevation BB

Rev Description Date By

1 : 100

Elevation D1

1 : 100

Elevation C2

Panelrib External Cladding

2° End to End Roof Aluminium Framed Windows

Wall Mounted Air ConditionerMetal Clad External Doors

150PFC Skid Beams

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

QLD

2/08

/201

2 1:

53:4

6 P

M

ATCO Structures & Logistics Pty. Ltd.18.0 x 12.0m Recreation Centre

TK

RA

WRC-1812-H-C2 -06

14.04.12

Sales Schedules C2

9b

Sales Window Schedule

No. Type Glazing Height WidthSill

Height Quantity CommentsRW1 Roller Window Colorbond 900 1208 1100 3W1 Sliding XO Grey Glass 900 1208 1000 10 c/w CurtainsW2 Sliding XO Grey Glass 900 1208 1200 2 c/w Curtains

Sales Roof Structure ScheduleRoof Structure Comments

2° End to End RoofC2 - SDEK/PLY LC7512 - 611 - (3.0 & 3.5)611mm Ceiling Joist CentresCeiling Joist - LC7512 GalvaspanInsulation - R2.3 Foil Backed Blanket - 95mmLining - Internal - 3.6mm Polyester CoatedPlywoodPurlins - C7510 / LC7512 GalvaspanRoof - 0.42mm BMT Superdek Roofing

- Wall ScheduleWall Structure Comments

External Wall611mm Stud CentresCladding External - Colorbond Maxirib -"Headland"

Lower firstsheet

Cladding External - Colorbond Maxirib -"Paperbark"

Upper Sheets

Framing - 75 x 1.0mm Hi-Ten TruecoreFraming - 75x1.0mm Hi-Ten SteelInsulation - R2.9 Batts - 75mmLining - Internal - 3.6mm Polyester CoatedPlywoodThermal Break between Framing and CladdingPly Internal Wall611mm Stud CentresFraming - 75 x 1.0mm Hi-Ten TruecoreLining - Internal - 3.6mm Polyester CoatedPlywood

* Plumbing FixturesNo. Description Quantity Comments

Plumbing - Water Inlet c/w Line Strainer 18 1200x450 S/S insert sink 29 7.5ltr Autoboiler 111 50Ltr Hot Water System - Internal c/w Safe Tray 217 5 Tap Stainless Steel Fill Up Station - 3000mm

long1

20 Water Cooler - Zip Freestanding EMBCF 60 -Mains Connected. SS Splashback.

1

22 Wall mounted water connection 5dp Dropper only, for 100 x 75mm Downpipe 12fw Floor Waste 3

Lighting Fixtures Quantity2x36W Fluro - Bare 24Dart Board Light 2Exit - Ceiling Mount 3Pool Table Light - Ceiling Mounted 2Single Vandalite - Wall Mounted2 5Switch - Std 6

- Electrical FixturesDescription Quantity

1x10amp GPO 11x20amp GPO 22x10amp GPO 21Draw Wire 7Isolation Switch - AC 12Photo Electric Cell 3Switchboard 6TV Antenna Socket 1

- FurnitureNo. Description Quantity Comments

4 Lounge Chair 105 PVC Stacker chair 606 1200 Dia. Melamine table 1414 Dart Board 215 Pool table c/w Cue Rack & pool Cues 218 600mm (W) Melamine benchtop c/w steel legs 1 5875 long

- CupboardsNo. Description Quantity Comments10a 600mm Wide Laminated benchtop c/w cupboards

x 2400. c/w 600 high SS Splashback1

10b 600mm Wide Laminated benchtop c/w cupboardsx 1800. c/w 600 high SS Splashback

1

13 600mm Wide Laminated benchtop c/w cupboards& 2 sets of drawers.

1 Leg 1650 &Leg 4600

Sales Mechanical EquipmentNo. Supplier Description QuantityM1 DAIKIN 5.0kW R/C Split System Air Conditioner - Inverter 12

- Floor Structure ScheduleFloor Structure Comments

Floor480mm Floor Joist CentresCovering - 1.5mm Polyflor XL VinylCovering - 2.0mm Polyflor Non-Slip Vinyl Inside Bar Area

& Ice Roomonly. 100mmCove

Flooring - 17mm F11 T&G PlywoodJoists - LC7512 Galvaspan

Wall Height2445

- Electrical Equipment ScheduleNo. Description Quantity Comments

1 Television - LCD - 50" - 127cm 13 MANITOWOC - Ice Machine - S-450 on B400

Storage Bin (173kg/24hr, 130kg holding capacity)2

7 Fridge - Single Door - 370 Litre - WRM3700WB 112 SKOPE Two Glass Door Chiller - B900-2 219 Dishwasher 1

- Fire Services ScheduleNo. Description Quantity

2 9.0Kg Fire Extinguisher - AB(E) 3

Manufacturing Structural Members

DescriptionMember

SizeBack to

BackSkid Beams c/w RetractableLifters

150PFC 2000

Paired Beams C20020

Sales Door Schedule

No. Panel Height WidthHandleType

HardwareSet Closer

PanicBar

C/BJamb

TimberJamb Security Quantity Comments

D1 Standard : Hollow Core MC 2040 1840 Lever Entrance Yes No Yes No 2 E/E SealsD2 Standard : Hollow Core MC 2040 920 Lever Entrance Yes No Yes No 3 E/E SealsD3 Standard : Hollow Core 2040 920 Lever Entrance Yes No Yes No 1D4 Standard : Hollow Core 2040 920 Lever Entrance Yes No Yes No 1

Rev Description Date By

ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

Carmichael ProjectQLD

Adani Mining Pty. Ltd.120842D

12.0 x 3.0m Laundry

- Drawing ListSheet

Number Sheet NameCurrentRevision

00 Title Page01 Floor Plan02 Elevations05 Sales Schedules

View indicative only

2 2 2

fw fw fw

DSB

PO

EPE

dp dpdp

2

fw fw

103

203

A

1 2

Bx

D12040

820

x

W11208900 x

W11208900

x

W11208900x

W11208900

1

3 3 3

1

3 3

1

3

1173 2222 2222 2222 2222 1775

Tub Tub Tub

1400

AFF

L

1400

AFF

L

1400

AFF

L

82

4

1400

AFF

L

1400

AFF

L

1400

AFF

L

1400

AFF

L14

00 A

FFL

1400

AFF

L

M1

300

AFFL

1200

AFF

L

9

82 11837 82

8228

3782

12000

3000

77 7 7 7 7

5 6 5 6 5 6

HWS

1400

AFF

L

1

3 3 3

1

1400

AFF

L

5 6 5

1400

AFF

L

7

1400

AFF

L

7

1400

AFF

L

7

3

1400

AFF

L

5

1400

AFF

L

7

650 803 803 803 803 803 2500 803 803 803 2263

M1

Tub Tub

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

Carmichael ProjectQLD

1 : 50

24/0

8/20

12 1

1:42

:45

AM

Adani Mining Pty. Ltd.12.0 x 3.0m Laundry

TK

RA

120842D -01

21.08.12

Floor Plan C2

10a

- Fire fighting equipment supplied & installed by others.- HWS (Capacity: 6 washing machine loads per hour @ 20 litres per load.- Floor Drains: One fixture per Floor Waste, all other fixtures discharge

direct to waste lines.- Plans are current at time of issue, are indicative only, and are subject to

change at any time without notice.

Notes1 Standard Laundry Unit - 45 Litre, Splashback & Wall Taps2 Water Cooler - Zip Freestanding EMBCF 60 - Mains Connected3 Washing Machine Taps4 1400 x 600 Melamine Table c/w Legs5 SPEED QUEEN 6.5kg Washing Machine6 SPEED QUEEN 6.5kg Washing Machine c/w Discharge Stand Pipe7 SPEED QUEEN 9kg Dryer8 ROBIN HOOD Ironing Centre & Hard Wired Steam Iron9 9.0Kg Fire Extinguisher - AB(E)dp Dropper only, for 100 x 75mm Downpipefw Floor WasteHWS Rheem Heat Pump 325 Litre/3.6kW -MPi - mounted externally

Item ListD1 2040 x 820 External Door - Standard : Hollow Core MC

W1 900 x 1208 Sliding Glass Window - Grey Glass

M1 Wall Mounted Exhaust Fan

Rev Description Date By

240V Smoke detector

Distribution Switchboard

External light18W Single Vandalite

36w Single fluorescent light

15amp Single GPO.10amp Double GPO10amp Single GPO

36w Single fluorescent light - IP65 rated

36w Double fluorescent light

10amp GPO - IPX5 rated

Comms. - Draw wire only

Light switchTwo-way light switch

Photo electric light switch

Spot light

'F' Type television outlet

Oyster light

Light switch - IPX5 rated

20amp Single GPO

Emergency exit light

Oyster Light - 11W Round Fluro

36w Emergency back-up fluorescent light

POE - Point Of Entry

- Indicates floor mounting- Indicates ceiling mounting

DSB

IPX5

IPX5

WP

EXIT

PE

Symbol Legend

2

Isolation Switch

PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point

OPTION

OPTIONOPTIONOPTIONOPTIONOPTION

FFL

0

Ceiling

2445

GL

-600

12

FFL

0

Ceiling

2445

GL

-600

1 2A B

AB

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

Carmichael ProjectQLD

1 : 75

24/0

8/20

12 1

1:42

:54

AM

Adani Mining Pty. Ltd.12.0 x 3.0m Laundry

TK

RA

120842D -02

21.08.12

Elevations C2

10a

1 : 75

Elevation AA

1 : 75

Elevation BB

2° Skillion Roof

Aluminium Framed Windows

Panelrib External Cladding

Metal Clad External Doors

150 PFC Skid Beams

Rev Description Date By

1 : 75

Elevation D1

1 : 75

Elevation C2

THIS DRAWINGREMAINS THEPROPERTY OF

ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN

PART WITHOUTWRITTEN AUTHORITY

QUALITYCERTIFIED TO

AS/NZS ISO9001:2008

BYSCI-QUAL

INTERNATIONALREGN No. 531

DATE

SCALE

DRAWN

CHECKED

TITLE

DRAWING NUMBER

PROJECT No. DESIGN WIND LOAD

REVISION SHEET SIZE

A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]

PHONE:FAX:

ABN:

(07) 3412 8600(07) 3803 0175

71 083 902 309

NCC BUILDING CLASS

Carmichael ProjectQLD

24/0

8/20

12 1

1:42

:58

AM

Adani Mining Pty. Ltd.12.0 x 3.0m Laundry

TK

RA

120842D -05

21.08.12

Sales Schedules C2

10a

Sales Window Schedule

No. Type Glazing Height WidthSill

Height Quantity CommentsW1 Sliding XO Grey Glass 900 1208 1200 4 C/w Curtains

Sales Roof Structure ScheduleRoof Structure Comments

2° End to End RoofC2 - SDEK/PLY LC7512 - 611 - (3.0 & 3.5)611mm Ceiling Joist CentresCeiling Joist - LC7512 GalvaspanInsulation - R2.3 Foil Backed Blanket - 95mmLining - Internal - 3.6mm Polyester CoatedPlywoodPurlins - C7510 / LC7512 GalvaspanRoof - 0.42mm BMT Superdek Roofing

- Wall ScheduleWall Structure Comments

External Wall611mm Stud CentresCladding External - Colorbond Maxirib -"Headland"

Lower firstsheet

Cladding External - Colorbond Maxirib -"Paperbark"

Upper Sheets

Framing - 75 x 1.0mm Hi-Ten TruecoreLining - Internal - 3.6mm Polyester CoatedPlywood

* Plumbing FixturesNo. Description Quantity Comments

1 Standard Laundry Unit - 45 Litre, Splashback &Wall Taps

5

2 Water Cooler - Zip Freestanding EMBCF 60 -Mains Connected

1 SS Splashback

3 Washing Machine Taps 10dp Dropper only, for 100 x 75mm Downpipe 3fw Floor Waste 5

HWS Rheem Heat Pump 325 Litre/3.6kW -MPi -mounted externally

1

Lighting Fixtures Quantity1x36W Fluro - Bare 4Single Vandalite - Wall Mounted 1Switch - Std 1

- Electrical FixturesDescription Quantity

1x10amp GPO 31x20amp GPO 102x10amp GPO 4Photo Electric Cell 1Switchboard 1

- FurnitureNo. Description Quantity Comments

4 1400 x 600 Melamine Table c/w Legs 1

Sales Mechanical EquipmentNo. Supplier Description QuantityM1 AIRFLOW Wall Mounted Exhaust Fan 2

- Floor Structure ScheduleFloor Structure Comments

Floor600mm Floor Joist CentresCovering - 1.5mm Polyflor XL Vinyl 100mm Cove

thoughoutFlooring - 17mm F11 T&G PlywoodJoists - LC7512 Galvaspan

Wall Height2445

- Electrical Equipment ScheduleNo. Description Quantity Comments

5 SPEED QUEEN 6.5kg Washing Machine 66 SPEED QUEEN 6.5kg Washing Machine c/w

Discharge Stand Pipe4

7 SPEED QUEEN 9kg Dryer 108 ROBIN HOOD Ironing Centre & Hard Wired

Steam Iron1

- Fire Services ScheduleNo. Description Quantity

9 9.0Kg Fire Extinguisher - AB(E) 1

Manufacturing Structural Members

DescriptionMember

SizeBack to

BackSkid Beams c/w RetractableLifters

150PFC 2000

Sales Door Schedule

No. Panel Height WidthHandleType

HardwareSet Closer

PanicBar

C/BJamb

TimberJamb Security Quantity Comments

D1 Standard : Hollow Core MC 2040 820 Standard Entrance No No Yes No 1

Rev Description Date By

OPTIONOPTION

OPTIONOPTION

OPTION

OPTION

CIVIL ENGINEERING DRAWINGS PREPARED BY CARDNO

DATUM RL 212.000

CUT/FILL DEPTHS

DESIGN LEVELS

EXISTING LEVELS

CHAINAGE

0.379

1.554

1.745

1.742

1.588

1.429

1.393

1.369

1.262

1.070

0.902

0.777

0.658

0.551

0.447

0.333

0.193

-0.00

2

-0.16

7

-0.43

0

-0.50

8

-0.57

6

-0.71

4

-0.90

6

-1.10

6

-1.23

6

-1.35

2

-1.47

1

-1.58

2

-1.74

9

-2.03

4

-2.40

9

-2.81

2

-2.75

6

-2.68

7

-2.63

8

-2.54

9

-2.45

9

220.8

79

222.0

56

222.2

50

222.2

50

222.0

99

221.9

43

221.8

93

221.8

69

221.7

62

221.5

70

221.3

65

221.1

58

220.9

58

220.7

69

220.5

83

220.3

88

220.1

93

219.9

98

219.7

29

219.3

61

219.1

71

218.9

85

218.7

86

218.5

94

218.3

94

218.1

65

217.9

36

217.7

04

217.4

79

217.2

51

216.9

27

216.4

74

215.9

93

215.9

93

215.9

93

215.9

93

215.9

93

215.9

93

220.4

81

220.5

00

220.5

00

220.5

00

220.5

00

220.5

02

220.5

05

220.5

08

220.5

11

220.5

14

220.5

00

220.5

00

220.5

00

220.5

00

220.4

63

220.3

81

220.3

00

220.2

18

220.1

37

220.0

55

220.0

00

220.0

00

219.8

96

219.7

91

219.6

80

219.5

61

219.5

00

219.5

00

219.5

00

219.4

02

219.2

88

219.1

74

219.0

61

219.0

00

218.9

62

218.8

83

218.8

05

218.7

49

218.6

80

218.6

31

218.5

42

218.4

52

218.3

62

218.2

72

218.1

74

00 20 40 60 80 100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

440

460

480

500

520

540

560

580

600

620

640

660

680

700

720

740

760

780

800

820

840

860

880

DATUM RL 216.000

CUT/FILL DEPTHS

DESIGN LEVELS

EXISTING LEVELS

CHAINAGE

DATUM RL 216.000

CUT/FILL DEPTHS

DESIGN LEVELS

EXISTING LEVELS

CHAINAGE

SCALESECTION

1:2000H11

SK106SCALE 1:200V

SCALESECTION

1:2000H10

SK106SCALE 1:200V

FINISHEDSURFACE

EXISTINGSURFACE

EXISTINGSURFACE

EXISTINGSURFACE

FINISHEDSURFACE

FINISHEDSURFACE

SIT

EB

DY

//

SIT

EB

DY

//

-0.02

0

0.148

0.314

0.584

0.838

1.112

1.372

1.629

1.873

1.935

1.823

1.746

1.669

1.595

1.434

1.213

0.964

0.663

0.394

0.218

0.018

220.4

80

220.5

93

220.7

34

220.9

80

221.2

10

221.4

44

221.6

79

221.9

14

222.1

33

222.1

84

222.0

72

221.9

55

221.8

38

221.7

25

221.5

24

221.2

58

220.9

64

220.6

63

220.3

62

220.0

65

219.7

68

220.5

00

220.5

00

220.5

00

220.5

00

220.5

00

220.4

45

220.4

20

220.3

96

220.3

72

220.3

32

220.3

07

220.2

84

220.2

59

220.2

49

220.2

49

220.2

09

220.1

70

220.1

30

220.0

90

220.0

45

220.0

00

220.0

00

219.9

67

219.8

47

219.7

51

219.6

61

00 20 40 60 80 100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

440

460

480

500

SCALESECTION

1:2000H12

SK106SCALE 1:200V

SIT

EB

DY

//

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

219.5

00

219.5

00

219.5

67

219.6

16

219.6

54

219.6

95

219.7

17

219.7

54

219.7

59

219.7

53

219.8

07

219.8

62

219.8

85

219.9

06

219.9

26

219.9

48

219.9

50

219.8

84

219.8

52

219.8

24

219.8

11

219.7

95

219.7

27

219.6

59

219.5

91

219.5

23

219.5

00

219.5

00

219.5

00

219.5

0021

9.500

219.5

00

219.5

00

219.5

67

219.6

16

219.6

54

219.6

95

219.7

17

219.7

54

219.7

59

219.7

53

219.8

07

219.8

62

219.8

85

219.9

06

219.9

26

219.9

48

219.9

50

219.8

84

219.8

52

219.8

24

219.8

11

219.7

95

219.7

27

219.6

59

219.5

91

219.5

23

219.5

00

219.5

00

219.5

00

219.5

0021

9.500

00 20 40 60 80 100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

440

460

480

500

520

540

560

580

588.4

42AS 9001 Lic. 5960Standards Australia

CompanyEndorsed

QualityACN: 051 074 992Cardno (Qld) Pty Ltd

Level 11, North Tower, 515 St Paul's Terrace, Fortitude Valley 4006Locked Bag 4006, Fortitude Valley Qld 4006Phone (07) 3369 9822 Fax (07) 3369 9722Email: [email protected] Web: www.cardno.com.auThe contents of this plan are conceptual only. All areas and dimensions are approximate and

subject to relevant studies, Survey, Engineering and Council approval.

ADANI MINING PTY LTDCAMP 4 BULK EARTHWORKS SECTIONS

REF NUMBER: 7508-90-SK107(----)DATE: 23.10.2012

DRAFT FOR DISCUSSION

2020 0 806040 100m

1:2000 - A1 1:4000 - A3

6.02.0 2.00 4.0 10.0m8.0

1:200 - A1 1:400 - A3

- PROPOSED MAJOR CONTOUR- PROPOSED MINOR CONTOUR

- AREA OF CUT

- AREA OF FILL

222.0222.2

- EXISTING CONTOUR222.2

AS 9001 Lic. 5960Standards Australia

CompanyEndorsed

QualityACN: 051 074 992Cardno (Qld) Pty Ltd

Level 11, North Tower, 515 St Paul's Terrace, Fortitude Valley 4006Locked Bag 4006, Fortitude Valley Qld 4006Phone (07) 3369 9822 Fax (07) 3369 9722Email: [email protected] Web: www.cardno.com.auThe contents of this plan are conceptual only. All areas and dimensions are approximate and

subject to relevant studies, Survey, Engineering and Council approval.

ADANI MINING PTY LTDCAMP 4 BULK EARTHWORKS LAYOUT

REF NUMBER: 7508-90-SK106(----)DATE: 23.10.2012

DRAFT FOR DISCUSSION

2020 0 806040 100m

1:2000 - A1 1:4000 - A3

SRMS

SS

S

S

S

S

S

S

S

SS

S

S

S

S

SS

S

S

S

SRM SRM SRM SRM SRM

S

S

SRM

SPSSPS

SEWERTREATMENT

PLANT

AS 9001 Lic. 5960Standards Australia

CompanyEndorsed

QualityACN: 051 074 992Cardno (Qld) Pty Ltd

Level 11, North Tower, 515 St Paul's Terrace, Fortitude Valley 4006Locked Bag 4006, Fortitude Valley Qld 4006Phone (07) 3369 9822 Fax (07) 3369 9722Email: [email protected] Web: www.cardno.com.auThe contents of this plan are conceptual only. All areas and dimensions are approximate and

subject to relevant studies, Survey, Engineering and Council approval.

ADANI MINING PTY LTDCAMP 4 SEWER RETICULATION LAYOUT

REF NUMBER: 7508-90-SK304(-)DATE: 22.10.2012

DRAFT FOR DISCUSSION

10 0 10 3020 40 50m

1:1000 - A1 1:2000 - A3

W

WW

WW

WW

W

W

WW

WW

W

W

W

W

W

W W W W W W W

WW

W

W

W

W

WW

WATERTREATMENT

PLANT

W W W W W

AS 9001 Lic. 5960Standards Australia

CompanyEndorsed

QualityACN: 051 074 992Cardno (Qld) Pty Ltd

Level 11, North Tower, 515 St Paul's Terrace, Fortitude Valley 4006Locked Bag 4006, Fortitude Valley Qld 4006Phone (07) 3369 9822 Fax (07) 3369 9722Email: [email protected] Web: www.cardno.com.auThe contents of this plan are conceptual only. All areas and dimensions are approximate and

subject to relevant studies, Survey, Engineering and Council approval.

ADANI MINING PTY LTDCAMP 4 WATER RETICULATION LAYOUT

REF NUMBER: 7508-90-SK404(-)DATE: 22.10.2012

DRAFT FOR DISCUSSION

10 0 10 3020 40 50m

1:1000 - A1 1:2000 - A3