> Camp Layout Package prepared by Cardno
> Civil Engineering Drawings prepared by Cardno
PART
10 PLANS AND DRAWINGS
ADANI MINING Pty Ltd Mine Camp
DATE DRAWING NO ISSUE
landscape architectureurban design
environmental management SP126801 -MC-01
RAIL CAMP TWORAIL CAMP
THREE
MINING CAMP
RAIL CAMP ONE
MORAHBAH
MORAY CARMICHAEL ROAD PROPOSED ACCESS ROAD
DISTANCE FROMMORAY CARMICHAEL ROADTO MINE CAMP1.0 KM
MINE CAMP
B22.10.12
TYPICAL SITE PHOTOS
LOCATION PLANSCALE 1:15,000 @ A3
FUTURE RAILWAY CORRIDOR
CONTEXTMINE CAMP
ADANI MINING Pty Ltd Mine Camp
DATE DRAWING NO ISSUE
landscape architectureurban design
environmental management SP126801 -MC-02 B22.10.12
LEGEND
MINE CAMP
ACCOMMODATION UNITS 504DISABLE UNITS 6CARPARKING 215 DISABLE CARPARKING 6BUS PARKING 6EFFLUENT DISPOSAL 5 ha(based on 100m2 per person)DETENTION BASINS 0.7haTOTAL OPEN SPACE 16.4ha(including firebreak) TOTAL SITE AREA 20.7 ha(excluding STP, WTP and laydown area)
ACCOMMODATION GROUP ISCALE 1 :1000
SCALE 1 :2,000
PLAN
0 1 2 3 5 10m
SCALE 1:250 @ A3
ADANI MINING Pty Ltd Mine Camp
DATE DRAWING NO ISSUE
landscape architectureurban design
environmental management B22.10.12 SP126801 -MC-03
MINE CAMP
Section O
ne
KEY
SECTIONS
SECT
ION
ON
E
PLANTED BUFFER ACCOMMODATION GROUP (24 PERSON)
Front of unitsSheltered walkway
Effluent Disposal Area
Effluent Disposal Area
Central spine path
Typical drainage swale
Covered Walkway
join
s be
low
join
s ab
ove
ACCOMMODATION GROUP (24 PERSON)
Sheltered walkway
Rear of units Private open space areafor each accommodation group
Private open space areafor each= accommodation group
PLANTED BUFFER DINING / KITCHEN COMMUNAL OPEN SPACE
Dining entry
Effluent Disposal Area
0 1 2 3 5 10m
SCALE 1:250 @ A3
ADANI MINING Pty Ltd Mine Camp
DATE DRAWING NO ISSUE
landscape architectureurban design
environmental management SP126801 -MC-04 B22.10.12
MINE CAMPSection Two
KEY
SECTIONS
SECT
ION
TW
O
CENTRAL PATH
CENTRAL PATH
Central covered walk-way connects to spine path
PLANTED BUFFER ( WITH ACCOMMODATION GROUP BEHIND) ACCOMMODATION GROUP (24 PERSON)
join
s be
low
join
s ab
ove
COMMUNAL OPEN SPACE
Units behind buffer
Private open space areafor each accommodation group
Communal Open Space with BBQ Facilities, Seating and Shelter
Private open space areafor each accommodation group
Breezway between units
Central covered walk-way connects to spine path
ACCOMMODATION GROUP (24 PERSON)
ADANI MINING Pty Ltd Mine Camp
DATE DRAWING NO ISSUE
landscape architectureurban design
environmental management
ADANI MINING CAMP
ATCO - 14.4 x 3.25M Three person doubleATCO - 14.4 x 3.25M VIP Two person DisabledATCO - 48.0 x 22.5 M Kitchen Diner (500 person)ATCO - 12.0 x 6.0 M OfficeATCO - 12.0 x 3.0 M Abulition BlockATCO - 12.0 x 3.0 M Linen StoreATCO - 12.0 x 12.0 M GymATCO - 18.0 x 12.0 M Recreation CentreATCO - 12.0 x 3.0 M Laundry
B22.10.12
MINE CAMPAPPENDICES
ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
Carmichael ProjectQLD.
Adani Mining Pty. Ltd.120842A2
14.4 x 3.25m VIP Three Person Double
- Drawing ListSheet
Number Sheet NameCurrentRevision
00 Title Page01 Floor Plan02 Elevations06 Sales Schedules
Views indicative only
fw
2
fw
2
fw
2
WP
WPWP
222
PE
RS RS RSTV 2 TV2TV2
dpdp dp
DSB
POE SMKTV
103
204
A
1 2 3 4
B
4802 4796 4802
8230
8682
TYPICAL DETAILAll Internal Fire / Sound Rated Wallsrun to outside wall faces.Refer Drg. L004
Rw
50(+
ctr)
SO
UN
D R
ATED
Rw
50(+
ctr)
SO
UN
D R
ATED
HWSISOLATOR
HWS EARTH
Stacked A/CCompressors
82 3613 86 945 152 3613 86 945 152 945 86 3613 82
304
3250 HWS
Steps indicated are indicative only
Stacked A/CIsolators
Single A/CCompressors
Stacked A/CIsolators
x
W19081200
x
W2750350
8
73
2
1
12
1310
11
9
654
x
D12040
820
M0
M1 M1
2
1
8
7
1210139
x
D12040
820
x
W19081200
M2 M2
x
W2750350
11
3
654
600
AFL
600 AFL
1280 AFL
1280
AFL
1280
AFL
1280
AFL
Key
Tag
150
0 AF
LLi
ght S
witc
h 12
80 A
FL
1280
AFL
1280 AFL
1400 AFL
1280 AFL
No Item Numbers in this end,.Electrical fixture heights showninstead.
203
M0
14400
M1
Waste manifold to discharge backside centre
RETICULATION POINTSMOKETV
M0
9 9
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
Carmichael ProjectQLD.
1 : 50
9/10
/201
2 10
:34:
26 A
M
Adani Mining Pty. Ltd.14.4 x 3.25m VIP Three Person Double
TK
RA
120842A2 -01
09.10.12
Floor Plan Reg. C Cat. 2
3
Plumbing - Waste Manifold OutletPlumbing - Water Inlet c/w Line Strainer
1 945 x 945 Fibreglass shower cubicle / Curtain. 3 Star WELS2 Hand Basin VC c/w Mirror Over - NOVATEC CARA inc.
overflow & PVC Waste3 WC Suite 4.5 Star WELS, c/w toilet roll holder4 Shaving Cabinet c/w 2 mirrored doors5 Towel Rail - 600w6 Two Coat Hooks on Timber Rail x 600w7 395w x 390d x 590h Bedside Three Drawer Unit8 Double bed c/w innerspring mattress9 1800h x 800w x 600d Robe c/w Shelves & Hanging Space10 Step Desk11 Shelving Over Desk - 1200mm Long Open12 Steel framed stacker chair13 Bar Fridge - WESTINGHOUSE - WRM1300WC - 130 litre14 9.0Kg Fire Extinguisher - AB(E)dp Dropper only, for 100 x 75mm Downpipefw Floor Waste
HWS Rheem Heat Pump 325 Litre/6kW -MPi - mounted externally
Item Lists
D1 2040 x 820 External Door - Standard : Hollow Core MCD2 2040 x 720 Internal Door - Standard : Hollow Core
W1 1200 x 908 Sliding Glass Window Grey GlassW2 350 x 750 Sliding Glass Window Obscure Glass
M0 A/C Vertical Two Piece CoverM1 2.5kW R/C Split System Air Conditioner - HybridM2 Wall Mounted Exhaust Fan
- Building designed in accordance with Queensland DevelopmentCode (QDC) MP3.3 - Temporary accommodation buildings andstructures.- Smoke Alarms and TV Outlets are reticulated to common point.- Exhaust fan and light in ensuite to be operated from same switch- Sound rated walls to run into roof cavity - refer to drawing details.
Notes
Energy Efficiency Notes- The design above is compliant for climate zones 1 & 3 for allorientations. Any changes to windows and/or external door sizes,quantity or locations will require re-submission for energy efficiencycompliance.- Under floor insulation not required under section P2 of QDC MP3.3 -Temporary Accommodation Building and Structures- For climate zones other than 1 & 3, energy efficiency calculation issubject to geographic location & site orientation.
Item Lists
Rev Description Date By
240V Smoke detector
Distribution Switchboard
External light18W Single Vandalite
36w Single fluorescent light
15amp Single GPO.10amp Double GPO10amp Single GPO
36w Single fluorescent light - IP65 rated
36w Double fluorescent light
10amp GPO - IPX5 rated
Comms. - Draw wire only
Light switchTwo-way light switch
Photo electric light switch
Spot light
'F' Type television outlet
Oyster light
Light switch - IPX5 rated
20amp Single GPO
Emergency exit light
Oyster Light - 11W Round Fluro
36w Emergency back-up fluorescent light
POE - Point Of Entry
- Indicates floor mounting- Indicates ceiling mounting
DSB
IPX5
IPX5
WP
EXIT
PE
Symbol Legend
2
Isolation Switch
PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point
FFL
0
Ceiling
2445
GL
-525
FFL
0
Ceiling
2445
GL
-525
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
Carmichael ProjectQLD.
1 : 75
9/10
/201
2 10
:34:
34 A
M
Adani Mining Pty. Ltd.14.4 x 3.25m VIP Three Person Double
TK
RA
120842A2 -02
09.10.12
Elevations Reg. C Cat. 2
3
1 : 75
Elevation AA
1 : 75
Elevation BB
2° Skillion Roof
Panelrib External Cladding
Aluminium Framed Windows
Metal Clad External Doors
310UB Skid Beams
1 : 75
Elevation C1
1 : 75
Elevation D2
Rev Description Date By
Reticulation PointsSmoke
POETV
PE Cell
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
Carmichael ProjectQLD.
9/10
/201
2 10
:34:
36 A
M
Adani Mining Pty. Ltd.14.4 x 3.25m VIP Three Person Double
TK
RA
120842A2 -06
09.10.12
Sales Schedules Reg. C Cat. 2
3
Sales Window Schedule
No. Type Glazing Height WidthSill
Height Quantity CommentsW1 Sliding XO Grey Glass 1200 908 1000 3 c/w CurtainsW2 Sliding XO.. Obscure Glass 350 750 1650 3
Sales Roof Structure ScheduleRoof Structure Comments
2° Skillion RoofC2 - SDEK/PLY LC7512 - 611 - (3.0 & 3.5)611mm Ceiling Joist CentresCeiling Joist - LC7512 GalvaspanInsulation - R2.3 Foil Backed Blanket - 95mmLining - Internal - 3.6mm Polyester CoatedPlywoodPurlins - C7510 / LC7512 GalvaspanRoof - 0.42mm BMT Superdek Roofing
- Wall ScheduleWall Structure Comments
External Wall407mm Stud CentresCladding External - Colorbond Maxirib -"Headland"
Lower
Cladding External - Colorbond Maxirib -"Paperbark"
Upper
Framing - 75 x 1.0mm Hi-Ten TruecoreInsulation - R2.9 Batts - 75mmLining - Internal - 3.6mm Polyester CoatedPlywoodThermal Break between Framing and CladdingInternal Wall - Fire / Sound Rated - Rw50 (+Ctr)611mm Stud CentresFraming - 92 x 0.5 'RHONDO' Quiet StudInsulation - R1.8 75mm Fibreglass Batt(14kg/m³)Lining - 2 x Layers 13mm Fyrecheck to bothsidesLining - Internal - 3.6mm Polyester CoatedPlywood (Finish layer to each side)Ply Internal Wall611mm Stud CentresFraming - 75 x 1.0mm Hi-Ten TruecoreLining - Internal - 3.6mm Polyester CoatedPlywood
* Plumbing FixturesNo. Description Quantity Comments
Plumbing - Waste Manifold Outlet 1Plumbing - Water Inlet c/w Line Strainer 1
1 945 x 945 Fibreglass shower cubicle / Curtain. 3Star WELS
3 Hot & Cold
2 Hand Basin VC c/w Mirror Over - NOVATECCARA inc. overflow & PVC Waste
3 Hot & Cold
3 WC Suite 4.5 Star WELS, c/w toilet roll holder 34 Shaving Cabinet c/w 2 mirrored doors 3dp Dropper only, for 100 x 75mm Downpipe 3fw Floor Waste 3
HWS Rheem Heat Pump 325 Litre/6kW -MPi -mounted externally
1
Lighting Fixtures Quantity1x18w Fluro - IP65 31x36W Fluro - Bare 3Reading Light - Oyster Shape 6Single Vandalite - Wall Mounted 2Switch - Key tag 3Switch - Std 12
- Electrical FixturesDescription Quantity
1x10amp GPO 32x10amp GPO 9240v Smoke Alarm 3External Smoke Junction Box 1External TV Junction Box 1Isolation Switch - AC 3Isolation Switch - HWS 1Photo Electric Cell 1Reed Switch 3Switchboard 1TV Antenna Socket 3
- FurnitureNo. Description Quantity Comments
5 Towel Rail - 600w 6 2 coat hooksabove / rail
6 Two Coat Hooks on Timber Rail x 600w 67 395w x 390d x 590h Bedside Three Drawer Unit 38 Double bed c/w innerspring mattress 39 1800h x 800w x 600d Robe c/w Shelves &
Hanging Space6
10 Step Desk 3 c/w space forBar Fridge
12 Steel framed stacker chair 3
- CupboardsNo. Description Quantity Comments11 Shelving Over Desk - 1200mm Long Open 3
Sales Mechanical EquipmentNo. Supplier Description QuantityM0 A/C
InstallerA/C Vertical Two Piece Cover 3
M1 DAIKIN 2.5kW R/C Split System Air Conditioner -Hybrid
3
M2 AIRFLOW Wall Mounted Exhaust Fan 3
- Floor Structure ScheduleFloor Structure Comments
Floor480mm Floor Joist CentresCovering - 1.5mm Polyflor XL Vinyl 100mm Cove -
BathroomFlooring - 17mm F11 T&G PlywoodJoists - LC10015 Galvaspan
Wall Height2445
- Electrical Equipment ScheduleNo. Description Quantity Comments13 Bar Fridge - WESTINGHOUSE - WRM1300WC -
130 litre3
- Fire Services ScheduleNo. Description Quantity14 9.0Kg Fire Extinguisher - AB(E) 2 1
Manufacturing Structural Members
DescriptionMember
SizeBack to
BackSingle Skid beams c/wRetractable lifters
310UB 2000
Sales Door Schedule
No. Panel Height WidthHandleType
HardwareSet Closer
PanicBar
C/BJamb
TimberJamb Security Quantity Comments
D1 Standard : Hollow Core MC 2040 820 Standard Entrance No No Yes No 3 Weather and E/E SealsD2 Standard : Hollow Core 2040 720 Standard Privacy No No Yes No 3
** Under floor insulation not required under section P2 of **QDC MP3.3 - Temporary Accommodation Building and
Structures
Refridgeration Pipes to run under floor
SWITCHBOARD: To have timer installed, via. Door Reed Switch,for all A/C units.Units to be shut down if door left open for more than 1 minute.
Rev Description Date By
ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
Carmichael ProjectQLD.
Adani Mining Pty. Ltd.120842A1
14.4 x 3.25m VIP Two Person - Disabled
- Drawing ListSheet
Number Sheet NameCurrentRevision
00 Title Page01 Floor Plan02 Elevations07 Sales Schedules
Views indicative only
fw
WP2
fw
WP 2
22 22 22
RSRS 222 2
dp dpdp
DSB
POESMKTVPE
103
205
A
1 2 3
B
7200 7200
8230
8682
HWSISOLATOR
HWS EARTH
305
3250 HWS
1000
AFL
Ligh
t Sw
itch
1000
AFL
No Item Numbers in this end,.Electrical fixture heightsshown instead.
x
D22040
1200
9
4
13
78
5
10
M2
11
1000 AFFL
1000 AFFL
1000
AFF
L
1000
AFF
L
1280
AFF
L
1100
AFF
L
123
AB
C
D
6
RETICULATION POINT
SMOKETV
82 4400 86 2589 86 2589 86 4400 82
2
x
W11208900
x
D12040
920
x
W21200350
x
W11208900
1000 AFFL
1280 AFFL
1100
AFF
L10
00 A
FFL
1400
AFL
1000
AFL
14400
203
FE
M0 M0
VIEWS
M1
RETICULATION POINTSMOKETV
Waste manifold to discharge backside centre
1240
OPTION
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
Carmichael ProjectQLD.
1 : 50
22/0
8/20
12 3
:01:
29 P
M
Adani Mining Pty. Ltd.14.4 x 3.25m VIP Two Person - Disabled
TK
RA
120842A1 -01
20.08.12
Floor Plan Reg. C Cat. 2
3
Plumbing - Waste Manifold OutletPlumbing - Water Inlet c/w Line Strainer
1 Disabled WC Suite - 2011, Grab Rails & Backrest2 Disabled Shower Type II - 2011 - c/w Fold-Up Seat & Grab Rails3 Chrome plated towel rail4 Disabled Vanity Unit c/w Laminated Bench Top & 1000 x 600
mirror over5 Mini Folding Frame Clothesline6 Washing Machine/Dryer Combo - Ariston ARMF125 on 300h plinth7 Washing Machine Taps8 Washing Machine Discharge Pipe9 King single bed c/w innerspring mattress10 Disabled Wardrobe - 2 Drawers11 Disabled Stepped Desk 1800 x 60012 Two Coat Hooks on Timber Rail x 600w13 Bar Fridge - WESTINGHOUSE - WRM1300WC - 130 litredp Dropper only, for 100 x 75mm DownpipeFE 9.0Kg Fire Extinguisher - AB(E)fw Floor Waste
HWS Rheem Heat Pump 325 Litre/6kW -MPi - mounted externally
Item ListsD1 2040 x 920 External Door - Standard : Hollow Core MCD2 2040 x 1200 Internal Door
-Standard : Sliding Hollow Core
W1 900 x 1208 Sliding Glass Window - Grey GlassW2 350 x 1200 Sliding Glass Window Obscure Glass
M0 A/C Vertical Two Piece CoverM1 Wall Mounted Exhaust FanM2 3.62kW R/C Split System Air Conditioner
- Building designed in accordance with Queensland DevelopmentCode (QDC) MP3.3 - Temporary accommodation buildings andstructures.
- Smoke Alarms and TV Outlets are reticulated to common point.- Exhaust fan and light in ensuite to be operated from same switch- Sound rated walls to run into roof cavity - refer to drawing details.
Notes
Energy Efficiency Notes- The design above is compliant for climate zones 1 & 3 for allorientations. Any changes to windows and/or external door sizes,quantity or locations will require re-submission for energy efficiencycompliance.- Under floor insulation not required under section P2 of QDC MP3.3 -Temporary Accommodation Building and Structures- For climate zones other than 1 & 3, energy efficiency calculation issubject to geographic location & site orientation.
Item Lists
Rev Description Date By
240V Smoke detector
Distribution Switchboard
External light18W Single Vandalite
36w Single fluorescent light
15amp Single GPO.10amp Double GPO10amp Single GPO
36w Single fluorescent light - IP65 rated
36w Double fluorescent light
10amp GPO - IPX5 rated
Comms. - Draw wire only
Light switchTwo-way light switch
Photo electric light switch
Spot light
'F' Type television outlet
Oyster light
Light switch - IPX5 rated
20amp Single GPO
Emergency exit light
Oyster Light - 11W Round Fluro
36w Emergency back-up fluorescent light
POE - Point Of Entry
- Indicates floor mounting- Indicates ceiling mounting
DSB
IPX5
IPX5
WP
EXIT
PE
Symbol Legend
2
Isolation Switch
PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point
FFL
0
Ceiling
2445
GL
-525
FFL
0
Ceiling
2445
GL
-525
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
Carmichael ProjectQLD.
1 : 75
22/0
8/20
12 3
:01:
37 P
M
Adani Mining Pty. Ltd.14.4 x 3.25m VIP Two Person - Disabled
TK
RA
120842A1 -02
20.08.12
Elevations Reg. C Cat. 2
3
1 : 75
Elevation AA
1 : 75
Elevation BB
2° End to End Roof
Panelrib External Cladding
Aluminium Framed Windows
Metal Clad External Doors
310UB Skid Beams
1 : 75
Elevation C1
1 : 75
Elevation D2
Rev Description Date By
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
Carmichael ProjectQLD.
22/0
8/20
12 3
:01:
39 P
M
Adani Mining Pty. Ltd.14.4 x 3.25m VIP Two Person - Disabled
TK
RA
120842A1 -07
20.08.12
Sales Schedules Reg. C Cat. 2
3
Sales Window Schedule
No. Type Glazing Height WidthSill
Height Quantity CommentsW1 Sliding XO Grey Glass 900 1208 1000 2 c/w CurtainW2 Sliding XO.. Obscure Glass 350 1200 1960 2
Sales Roof Structure ScheduleRoof Structure Comments
2° End to End RoofC2 - SDEK/PLY LC7512 - 611 - (3.0 & 3.5)611mm Ceiling Joist CentresCeiling Joist - LC7512 GalvaspanInsulation - R2.3 Foil Backed Blanket - 95mmLining - Internal - 3.6mm Polyester CoatedPlywoodPurlins - C7510 / LC7512 GalvaspanRoof - 0.42mm BMT Superdek Roofing
- Wall ScheduleWall Structure Comments
External Wall611mm Stud CentresCladding External - Colorbond Maxirib -"Headland"
Lower
Cladding External - Colorbond Maxirib -"Paperbark"
Upper
Framing - 75 x 1.0mm Hi-Ten TruecoreInsulation - R2.9 Batts - 75mmLining - Internal - 3.6mm Polyester CoatedPlywoodThermal Break between Framing and CladdingPly Internal Wall611mm Stud Centres75mm Glasswool batt to wall hatchedFraming - 75 x 1.0mm Hi-Ten TruecoreLining - Internal - 3.6mm Polyester CoatedPlywood
* Plumbing FixturesNo. Description Quantity Comments
Plumbing - Waste Manifold Outlet 1Plumbing - Water Inlet c/w Line Strainer 1
1 Disabled WC Suite - 2011, Grab Rails &Backrest
2
2 Disabled Shower Type II - 2011 - c/w Fold-UpSeat & Grab Rails
2
3 Chrome plated towel rail 24 Disabled Vanity Unit c/w Laminated Bench Top
& 1000 x 600 mirror over2 c/w Mirror. Disabled Compliant
5 Mini Folding Frame Clothesline 2 Set 1200 AFFL7 Washing Machine Taps 28 Washing Machine Discharge Pipe 2dp Dropper only, for 100 x 75mm Downpipe 3fw Floor Waste 2
HWS Rheem Heat Pump 325 Litre/6kW -MPi -mounted externally
1
Lighting Fixtures Quantity1x36W Fluro - Bare 21x36W Fluro - IP65 2Reading Light - Oyster Shape 4Single Vandalite - Wall Mounted 2Switch - Std 8
- Electrical FixturesDescription Quantity
1x10amp GPO AC 21x15amp GPO AC 22x10amp GPO 12240v Smoke Alarm 2Draw Wire 2External Smoke Junction Box 1External TV Junction Box 1Isolation Switch - HWS 1Photo Electric Cell 1Reed Switch 2Switchboard 1
- FurnitureNo. Description Quantity Comments
9 King single bed c/w innerspring mattress 210 Disabled Wardrobe - 2 Drawers 2 Disabled Compliant 1 Lh & 1 RH11 Disabled Stepped Desk 1800 x 600 212 Two Coat Hooks on Timber Rail x 600w 2
Sales Mechanical EquipmentNo. Supplier Description QuantityM0 A/C
InstallerA/C Vertical Two Piece Cover 2
M1 AIRFLOW Wall Mounted Exhaust Fan 2M2 TECO 3.62kW R/C Split System Air Conditioner 2
- Floor Structure ScheduleFloor Structure Comments
Floor600mm Floor Joist CentresCovering - 2.0mm Polyflor Non-Slip Vinyl Bathrooms -
100mm CoveCovering - 2.0mm Polyflor XL Vinyl BedroomsFlooring - 17mm F11 T&G PlywoodInsulation - Under Floor - 15mm FoilboardJoists - LC10015 Galvaspan
Wall Height2445
- Electrical Equipment ScheduleNo. Description Quantity Comments
6 Washing Machine/Dryer Combo - Ariston ARMF125 on 300h plinth 213 Bar Fridge - WESTINGHOUSE - WRM1300WC - 130 litre 2
- Fire Services ScheduleNo. Description QuantityFE 9.0Kg Fire Extinguisher - AB(E) 2 1
Manufacturing Structural Members
DescriptionMember
SizeCentre to
CentreSingle Skid beams c/wRetractable lifters
310UB 2000
Sales Door Schedule
No. Panel Height WidthHandleType
HardwareSet Closer
PanicBar
C/BJamb
TimberJamb Security Quantity Comments
D1 Standard : Hollow Core MC 2040 920 Lever Entrance No No Yes No 2 E/E & Weather SealsD2 Standard : Sliding Hollow Core 2040 1200 Privacy No Yes 2 Flush Pull Handle
Refridgeration Pipes to run under floor
SWITCHBOARD: To have timer installed, via. Door Reed Switch,for all A/C units.Units to be shut down if door left open for more than 1 minute.
Rev Description Date By
OPTIONOPTION
OPTION
OPTION
OPTION
OPTION
OPTION
OPTION
OPTION
ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
KD-500-H-C2
Kitchen Diner - 48.0 x 22.5m
ATCO Structures & Logistics Pty Ltd
- Drawing ListSheet
Number Sheet NameCurrentRevision
00 Title Page A01 Floor Plan A02 Elevations A05 Kitchen Sections A07 Sales Schedules A
View indicative only
COOKING CAPACITY = 500 PersonSEATING CAPACITY = 300 Person
fw
IPX5
fw
fw
fw
fw
IPX5
fw
fw
fw
fw
fw
PEPOE POE POE POE POE
DSB
POE
DSB
POE
WP
WP
WP
WP
BUG
EXI
T
EXIT
EXIT
EXI
T
BUG
2
2
2
222222
2222
2
2
2
WP
WP
WP
WP
fw
WP
WP
DSB
POE
2
2
PE
EXI
T
2
2
2
S S
S S
DSB
POE
DSB
POE
DSB
POE
DSB
POE
DSB
POE
DSB
POEdp dp dp dp dp dp dp dp dpdp dp dp dp dp dp dp
dp dp dp dp dp dp dp dp dp dp dp dp dp dp dp
BUG
2
2
DSBP
OE D
SBPO
E
dp
dpdp 2
dpPE
EXI
T
BUG
fw
fw
fw
2
DSBP
OE
dp
fw
BUG
EXIT
104
204
A
1
1
2
2
3 4 5
B
03
03
02
02
01
01
0
0
06 05 04 6 7 8 907
M9M10M10
29
FREEZER
DRYSTORECHILLER
9
10
11
11
12
5
13
13
1 1
2221
3
19a
40
2424
24a
25
VEGETABLE
MEAT
BAKERY
32
3534
3534
M5
26
x
D22040
1740 x
D12040
1840
M1
M1
M1
M1
x
D52040
920
x
D42040
920
x
O242001200
C20
020
Pai
red
Bea
ms
x
O110001200
23
C30
030
Stiff
ened
& C
ambe
red
Pai
red
Bea
ms
x
W31200350
x
W11208900
M3
x
W11208900x
W11208900x
W11208900
M4
4
M2
x
W11208900
CO
VER
ED L
OA
DIN
G D
OC
K
304
105
205
305
405
505
605
705
805
159 2837 168 2832 6000 3000 3000 168 26834 82
8211
837
82 8211
837
82
Freezer 2800
200
Col
droo
ms
480
020
00C
old
Roo
ms
4800
200
1200
015
0090
00
48000
3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000
DSBDSB
DSB
3130
31 313030
31
3130
30
HWSHWS
3130
31 313030
31
3130
30
2
3
4
215b15a
15b
3
3000
C
E
D
3000
3000
3000
604
14 14
1200
0
FREEZER
CHILLER
FREE
ZER
CH
ILLE
R
DRYSTORE
x
D52040
920
M2
DSB DSB
x
W11208900
x
W11208900
M3
M3
31 313030
31 313030
31 313030
31 313030
31 313030
31 313030
31 313030
31 313030
31 313030
31 313030
31 313030
31 313030
31 313030
31 313030
31 313030
31 313030
31 313030
31 313030
3130
3130
3130
3130
M11 M11
M9
27
25
Freezer 2800 Freezer / Chiller 2800
Covered Entry/Exit- Indicative Only
x
D71900
800
x
D71900
800x
D61900
800
x
D61900
800x
D61900
800
x
D71900
800
x
D71900
800
12000 12000 24000
3000
4500
2000
1200
12
19b25
DISH RETURN
HC
HC
17a
17a 17a
17a
17c17c
17b
17a
17a17a
17c 17c
17b
17a
28
Freezer 2800Freezer 2800
Chiller 2868Chiller 2800
Covered Entry/Exit- Indicative Only
3636
1
C30030 Stiffened & Cambered Paired Beams
x
W11208900
x
D12040
1840
x
W11208900
141
14
1
M1
M12222
15b15b
15b
Covered Entry/Exit- Indicative Only
4500
2000
8288
3782
9000
283435
x
O32040
1837
2020 20
8
8a
3333
18a
18b
18a 18a
18b
18a 18a 18a
18b18b
18a 18a
18d
18g 18g
18g
18d
18f
18e
18a
18c
18a18a
18c
18a18a
18c
18a18a
18c
18a
18d
7j
7f
7c
7b
7h
7a
6b
2
22a
22a
Flus
hFl
ush
Flus
hFl
ush
Flus
h
M3
x
D12040
1840 28
F
M3
x
D42040
920
M4
x
W11208900
M4
114
11
M3M3M3M3M3
x
W11208900
x
W11208900
M3
x
W11208900
M3
x
W11208900
M3
x
W11208900
M3
x
W11208900
M3
x
W21208600
M3
x
W21208600
M3
M4
x
W11208900
x
W11208900
M4
M4
x
W11208900
3000
6000
2000
3000
320
2780
2120
2080
3600
2080
2120
16a16
40
24
6a
M6M7
x
O32040
1837
x
D32040
820
82 11837 82
12000
M1 M1
2250
0
7d
M8
41
THIS DRAWING REMAINS THE PROPERTY OF ATCOSTRUCTURES PTY. LTD. IT MAY NOT BE REPRODUCED
OR COPIED WHOLE OR IN PART WITHOUT WRITTENAUTHORITY
© COPYRIGHT
QUALITY CERTIFIED TO AS/NZS ISO 9001:2008BY
SCI-QUAL INTERNATIONAL REGN No. 531
PROJECT No.
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER REVISION SHEET SIZE
A1
DESIGN WIND LOAD
ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD,
QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD
4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
1 : 100
12/0
9/20
12 9
:17:
27 A
M
A
ATCO Structures & Logistics Pty Ltd
Kitchen Diner - 48.0 x 22.5m
TK
RA
KD-500-H-C2 -01
31.05.12
Floor Plan
Reg. C Cat. 2 6
- Fire fighting equipment supplied & installed by others.- Freezer & Chillers to comply with NCC G.12
Notes
1 : 100
Floor Plan1
18a Shelving 4 Tier Post Style with ABS Shelves - 1800h x1500w x 600d
18b Shelving 4 Tier Post Style with ABS Shelves - 1800h x1200w x 600d
18c Shelving 4 Tier Post Style with ABS Shelves - 1800h x1350w x 600d
18d Shelving 4 Tier Post Style with ABS Shelves - 1800h x750w x 600d
18e Shelving 3 Tier Post Style with ABS Shelves - 1200h x1200w x 600d
18f Shelving 3 Tier Post Style with ABS Shelves - 1200h x600w x 600d
18g Shelving 4 Tier Post Style with ABS Shelves - 1800h x1200w x 600d
19a Planetary Mixer - 40 litre19b Planetary Mixer - 20 litre20 Hand Basin, Stainless Steel - Knee Operated (Hot & Cold)21 Semi Automatic Slicer22 Two Glass Door Chiller - 1120 Litres22a Single Glass Door Chiller - 600 Litres24 600 x 450 x 380 deep Sink c/w Pot Wash Item 4024a 600 x 450 x 380 deep Sink c/w Flickmixer25 450 x 450 x 300 deep Sink c/w Flickmixer26 Tubular Tray Race x 4200w27 Pot Rack 4 Tier Post Style with Wire Grid Shelves 1800h x
1200w x 600d28 4 Tap Stainless Steel Wash Trough 1800mm long29 Cleaners sink with hinged grate (Hot & Cold Tap Only)30 Steel Framed Stacker Chair31 1800 x 750 Melamine lunch table32 Potato Peeler33 Infill Bench - 450w 750d (300 high Splashback)34 9.0Kg Fire Extinguisher - AB(E)35 Fire Blanket36 Ice Cream Freezer - 183 Litre40 Pot Wash - Hob Mounted Pre Rinse & Add On Pot Filler41 MicrowaveBUG Electronic Bug Killer - 2 x 20Wdp Dropper only, for 100 x 75mm DownpipeDSB Switchboardfw Commercial Floor WasteHC Hose CockHWS 315Ltr Triple element hot water system - mounted
externally
Plumbing - Water Inlet c/w Line Strainer1 Salad Bar - 6 Mod - Storage Under / Glass Canopy2 Drinks Dispenser - 4 x 12 Litre3 Conveyor Toaster4 BIRKO 15ltr Autoboiler5 Rack - Conveyor Dishwasher6a Dish Return c/w Scraps Hole / Chute (1400 x 2825 x 2900)
(300 high Splashback with 600 high wall cover)6b Dishwash Exit - 1500 x 700 (300 high Splashback with
600 high wall cover)7a Prep Bench - Meat 01 x 2700w (300 high Splashback)7b Prep Bench - Meat 02 x 4200w (300 high Splashback)7c Prep Bench - Bakery 01 x 3200w (300 high Splashback)7d Prep Bench - Bakery 02 x 4000w (300 high Splashback) to
inc. 600 Stepdown x 700w7f Prep Bench - Vege 01 x 4000w inc. Stepdown7h Mobile Bench - Meat x 1200w (No Splashback)7j Mobile Bench - Vege x 1200w (No Splashback)8 Combi Oven - Electric8a Combi Oven - Electric9 Tilting Bratt Pan - Electric - 150 Litre10 Deep Fryer - Electric - 3 Pan x 21 Litre11 Griddle - Electric12 Range - Electric - 8 Element13 Hot Bain Marie - 6 Mod - Heated Storage Under / Sneeze
Guard14 Mobile Bench - Diner x 1800w x 750d x 900h (No
Splashback)15a Beverage Bench x 2850w (600 high Splashback)
Splashback to LH side15b Beverage Bench x 2900w (600 high Splashback)16 Prep Bench - Cooking x 2900w (300 high Splashback)16a Prep Bench - Cooking - Shelf x 2900w17a Shelving 4 Tier Post Style with Wire Grid Shelves 1800h x
1800w x 600d17b Shelving 4 Tier Post Style with Wire Grid Shelves 1800h x
1500w x 600d17c Shelving 4 Tier Post Style with Wire Grid Shelves 1800h x
1200w x 600d
Item ListsD1 2040 x 1840 External Double Door - Standard : Hollow Core MCD2 2040 x 1740 External Double Door - Standard : Hollow Core MCD3 2040 x 820 External Door - Standard : Hollow Core MCD4 2040 x 920 Internal Door - Half Glass : Solid CoreD5 2040 x 920 Internal Door - Half Glass : Hollow CoreD6 1900 x 800 Internal Door - Standard : Coldroom Panel DoorD7 1900 x 800 Internal Door - Standard : Freezer Panel DoorO3 Opening Only - 2040 x 1837 Opening Only
O1 1200 x 1000 Window opening Dish ReturnO2 1200 x 4200 Servery Servery WindowW1 900 x 1208 Sliding Glass Window - Grey GlassW2 600 x 1208 Sliding Glass Window - Obscure GlassW3 350 x 1200 Sliding Glass Window Obscure Glass
M1 900mm Air CurtainsM2 3.5kW R/C Split System Air Conditioner - InverterM3 5.0kW R/C Split System Air Conditioner - InverterM4 7.1kW R/C Split System Air Conditioner - InverterM5 Fresh Air Dual Kitchen Induction SystemM6 Exhaust Canopy - Main x 6300wM7 Exhaust Canopy - Secondary x 5400M8 Vent Hood for ES100 Rack - Conveyor DishwasherM9 External Compressors - Freezer / ChillerM10 External Compressor - FreezerM11 External Compressor - Chiller
Rev Description Date ByA Issed for Review 04.09.12 RA
COOKING CAPACITY = 500 PersonSEATING CAPACITY = 300 Person
C2 STRUCTURAL NOTES - Minimum Design Criteria
Dead and Live Windloads in accordance with the latest version of AS1170.2Wind Region: C - Terrain Category: 2Strength Design Wind Speed: Vu = 61.2m/s (61)Serviceability Wind Speed: Vs = 39.5m/s (39)Shielding Multiplier: 1.0 Topographic Multiplier: 1.0Earthquake Loads in accordance with the latest version of AS1170.4
WINDOW SPECIFICATIONULS (ULTIMATE) - 4.44kPASLS (SERVICEABILITY) - 1.33kPAWATER PENETRATION - 450PA
EXIT
240V Smoke detector
Distribution Switchboard
External light18W Single Vandalite
36w Single fluorescent light
15amp Single GPO.10amp Double GPO10amp Single GPO
36w Single fluorescent light - IP65 rated
36w Double fluorescent light
10amp GPO - IPX5 rated
Comms. - Draw wire only
Light switchTwo-way light switch
Photo electric light switchSpot light
'F' Type television outlet
Oyster light
Light switch - IPX5 rated
20amp Single GPO
Emergency exit lightOyster Light - 11W Round Fluro
36w Emergency back-up fluorescent light
POE - Point Of Entry
- Indicates floor mounting- Indicates ceiling mounting
DSB
IPX5
IPX5
WP
PE
Symbol Legend
2
Isolation Switch
PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point
FFL
0
Ceiling
2445
GL
-775
12345 0302010 0605046789 07
FFL
0
Ceiling
2445
GL
-775
1 2 3 4 503 02 01 006 05 04 6 7 8 907
FFL
0
Ceiling
2445
GL
-775
ABCE DF
FFL
0
Ceiling
2445
GL
-775
A B C ED F
THIS DRAWING REMAINS THE PROPERTY OF ATCOSTRUCTURES PTY. LTD. IT MAY NOT BE REPRODUCED
OR COPIED WHOLE OR IN PART WITHOUT WRITTENAUTHORITY
© COPYRIGHT
QUALITY CERTIFIED TO AS/NZS ISO 9001:2008BY
SCI-QUAL INTERNATIONAL REGN No. 531
PROJECT No.
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER REVISION SHEET SIZE
A1
DESIGN WIND LOAD
ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD,
QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD
4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
As indicated
12/0
9/20
12 9
:18:
16 A
M
A
ATCO Structures & Logistics Pty Ltd
Kitchen Diner - 48.0 x 22.5m
TK
RA
KD-500-H-C2 -02
31.05.12
Elevations
Reg. C Cat. 2 6
1 : 100
Elevation AA
1 : 100
Elevation BB
2° End to End Roof
Panelrib External CladdingAluminium Framed Windows
Metal Clad External Doors
200PFC Skid Beams
Rev Description Date ByA Issed for Review 04.09.12 RA
1 : 50
Elevation C1
1 : 50
Elevation D2
FFL
0
Ceiling
2445
GL
-775
AB
2
C AB
35
34 13 13
15a
M4
C
FFL
0
Ceiling
2445
GL
-775
A B
Energy Efficiency andEmergency Lighting ControlPanel
Cooking Equipment Isolator
EMERGENCY STOP
DishReturn
Canopy /SupplyAir Fan
COOKINGDISHWASH
13 13
900
AB
Stainless Steel Sheet to wall - floor to underside of canopy, full lengthof canopy and to full width of canopy on end wall
COOKINGDISHWASH
C
Emergency Stop
12 11 11 33 105
6b
4080
M8
FFL
0
Ceiling
2445
GL
-775
A BStainless Steel Sheet to wall - floorto underside of canopy, full widthof canopy
VEGETABLEMEAT
HWS
Emergency Stop
27
12 98 8a
7a 7h7j
FFL
0
Ceiling
2445
GL
-775
AB
2132
Energy Efficiencyand EmergencyLighting ControlPanel
Cooking Equipment IsolatorEMERGENCY STOP
Canopy fan
VEGETABLEMEAT
1330
1440 17
00
FFL
0
Ceiling
2445
GL
-775
A B
34
35
22
19b
7c
FFL
0
Ceiling
2445
GL
-775
AB
19a
THIS DRAWING REMAINS THE PROPERTY OF ATCOSTRUCTURES PTY. LTD. IT MAY NOT BE REPRODUCED
OR COPIED WHOLE OR IN PART WITHOUT WRITTENAUTHORITY
© COPYRIGHT
QUALITY CERTIFIED TO AS/NZS ISO 9001:2008BY
SCI-QUAL INTERNATIONAL REGN No. 531
PROJECT No.
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER REVISION SHEET SIZE
A1
DESIGN WIND LOAD
ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD,
QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD
4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
1 : 50
12/0
9/20
12 9
:18:
22 A
M
A
ATCO Structures & Logistics Pty Ltd
Kitchen Diner - 48.0 x 22.5m
TK
RA
KD-500-H-C2 -05
31.05.12
Kitchen Sections
Reg. C Cat. 2 6
Rev Description Date ByA Issed for Review 04.09.12 RA
1 : 50
Section 41
1 : 50
Section 52
1 : 50
Section 63
1 : 50
Section 74
1 : 50
Section 85 1 : 50
Section 96
1 : 50
Section 107 1 : 50
Section 118
THIS DRAWING REMAINS THE PROPERTY OF ATCOSTRUCTURES PTY. LTD. IT MAY NOT BE REPRODUCED
OR COPIED WHOLE OR IN PART WITHOUT WRITTENAUTHORITY
© COPYRIGHT
QUALITY CERTIFIED TO AS/NZS ISO 9001:2008BY
SCI-QUAL INTERNATIONAL REGN No. 531
PROJECT No.
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER REVISION SHEET SIZE
A1
DESIGN WIND LOAD
ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD,
QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD
4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
12/0
9/20
12 9
:18:
24 A
M
A
ATCO Structures & Logistics Pty Ltd
Kitchen Diner - 48.0 x 22.5m
TK
RA
KD-500-H-C2 -07
31.05.12
Sales Schedules
Reg. C Cat. 2 6
Sales Window Schedule
No. Type Glazing Height WidthSill
Height Quantity CommentsO1 Window Opening only Dish Return 1200 1000 900 1O2 Window Opening only Servery Window 1200 4200 880 1W1 Sliding XO Grey Glass 900 1208 1000 19W2 Sliding XO1 Obscure Glass 600 1208 1300 3 45° SillW3 Sliding XO.. Obscure Glass 350 1200 1550 1 45° Sill
Sales Roof Structure ScheduleRoof Structure Comments
2° End to End RoofC2 - SDEK/PBD LC10015 - 400 - (3.0 & 3.5)Ceiling Joist Centres - Kitchen 400mm - Diner 611mmCeiling Joist - LC10015 GalvaspanInsulation - R2.3 Foil Backed Blanket - 95mmLining - Internal - 3.6mm Mirage Pearl PlywoodLining - Internal - 6mm Villaboard Kitchen Area.
Loading DockCeiling.
Purlins - C7510 / LC7512 GalvaspanRoof - 0.42mm BMT Superdek Roofing DINER ONLYRoof - 0.48mm BMT Superdek Roofing KITCHEN
ONLY
- Wall ScheduleWall Structure Comments
Coldroom / Freezer WallsPanel0.6mm Colorbond Skin100mm EPS Panel Coldroom150mm EPS Panel FreezerExternal WallStud Centres - Diner 611mm - Kitchen 400mmCladding External - Colorbond Maxirib -"Headland"
Lower firstsheet
Cladding External - Colorbond Maxirib -"Paperbark"
Upper Sheets
Framing - 75 x 1.0mm Hi-Ten TruecoreInsulation - R2.9 Batts - 75mmInsulation - Sisalation Kitchen
External WallsLining - 6mm Villaboard Kitchen AreaLining - Internal - 3.6mm Polyester CoatedPlywood
Diner
Thermal Break between Framing and CladdingExternal Wall / Double600mm Stud CentresCladding External - Colorbond Maxirib -"Headland"
Lower firstsheet
Cladding External - Colorbond Maxirib -"Paperbark"
Upper Sheets
Framing - 2 Walls - 75 x 1.0mm Hi-TenTruecoreInsulation - R2.9 Batts - 75mmLining - 6mm Villaboard Kitchen AreaThermal Break between Framing and CladdingVillaboard Double Internal Wall400mm Stud CentresFraming - 2 Walls - 75 x 1.0mm Hi-TenTruecoreLining - 6mm Villaboard Kitchen AreaVillaboard Internal Wall400mm Stud CentresFraming - 75 x 1.0mm Hi-Ten TruecoreLining - 6mm Villaboard Kitchen Area
* Plumbing FixturesNo. Description Quantity Comments
Plumbing - Water Inlet c/w Line Strainer 14 BIRKO 15ltr Autoboiler 220 Hand Basin, Stainless Steel - Knee Operated (Hot &
Cold)3
24 600 x 450 x 380 deep Sink c/w Pot Wash Item 40 3 Hot & Cold24a 600 x 450 x 380 deep Sink c/w Flickmixer 1 Hot & Cold25 450 x 450 x 300 deep Sink c/w Flickmixer 3 Hot & Cold28 4 Tap Stainless Steel Wash Trough 1800mm long 329 Cleaners sink with hinged grate (Hot & Cold Tap Only) 140 Pot Wash - Hob Mounted Pre Rinse & Add On Pot Filler 2 Hot & Colddp Dropper only, for 100 x 75mm Downpipe 36fw Commercial Floor Waste 15HC Hose Cock 2
HWS 315Ltr Triple element hot water system - mountedexternally
2
Lighting Fixtures Quantity1x36W Fluro - IP65 102x36W Fluro & Diffuser 68Exit - Ceiling Mount 4Exit - Ceiling Mount Directional 2Exit - Wall Mount 1Single Vandalite - Wall Mounted 1Spitfire 10W - Emegency Light - Battery Backup 9Switch - IPX5 2Switch - Std 14
- Electrical FixturesDescription Quantity
1x10amp GPO 71x10amp GPO - Ceiling Mounted 51x10amp GPO - Floor Mounted 101x10amp GPO - Suspended 21x15amp GPO 81x15amp GPO - Suspended 21x15amp GPO AC 91x20amp 3Ø Point 12x10amp GPO 25Emergency Stop 2Emergency Stop on Canopy 2Energy Efficiency and Emergency Lighting Control Panel(HAGER)
2
Isolation Switch - AC 25Isolation Switch - HWS 2Mains Switchboard 5On-Off Switch 4Photo Electric Cell 3POE 5Switchboard 12
- Furniture
No. DescriptionManufactur
er Quantity17a Shelving 4 Tier Post Style with Wire Grid Shelves 1800h x
1800w x 600dMANTOVA 8
17b Shelving 4 Tier Post Style with Wire Grid Shelves 1800h x1500w x 600d
MANTOVA 2
17c Shelving 4 Tier Post Style with Wire Grid Shelves 1800h x1200w x 600d
MANTOVA 4
18a Shelving 4 Tier Post Style with ABS Shelves - 1800h x1500w x 600d
MANTOVA 16
18b Shelving 4 Tier Post Style with ABS Shelves - 1800h x1200w x 600d
MANTOVA 4
18c Shelving 4 Tier Post Style with ABS Shelves - 1800h x1350w x 600d
MANTOVA 4
18d Shelving 4 Tier Post Style with ABS Shelves - 1800h x750w x 600d
MANTOVA 3
18e Shelving 3 Tier Post Style with ABS Shelves - 1200h x1200w x 600d
MANTOVA 1
18f Shelving 3 Tier Post Style with ABS Shelves - 1200h x600w x 600d
MANTOVA 1
18g Shelving 4 Tier Post Style with ABS Shelves - 1800h x1200w x 600d
MANTOVA 3
26 Tubular Tray Race x 4200w 127 Pot Rack 4 Tier Post Style with Wire Grid Shelves 1800h x
1200w x 600dMANTOVA 1
30 Steel Framed Stacker Chair 30031 1800 x 750 Melamine lunch table 50
Sales Mechanical EquipmentNo. Supplier Description QuantityM1 TECO 900mm Air Curtains 8M2 DAIKIN 3.5kW R/C Split System Air Conditioner -
Inverter2
M3 DAIKIN 5.0kW R/C Split System Air Conditioner -Inverter
17
M4 DAIKIN 7.1kW R/C Split System Air Conditioner -Inverter
6
M5 Aircon Eng. Fresh Air Dual Kitchen Induction System 1M6 T&H Sheetmetal Exhaust Canopy - Main x 6300w 1M7 T&H Sheetmetal Exhaust Canopy - Secondary x 5400 1M8 T&H Sheetmetal Vent Hood for ES100 Rack - Conveyor
Dishwasher1
M9 External Compressors - Freezer / Chiller 1M10 External Compressor - Freezer 2M11 External Compressor - Chiller 2
- Floor Structure ScheduleFloor Structure Comments
DECK400mm Floor Joist CentresFlooring - 19 x 89mm ShotedgeFraming - LC7512 Galvaspan
DINER FLOOR480mm Floor Joist CentresCovering - 2.0mm Polyflor XL VinylFlooring - 17mm F11 T&G PlywoodJoists - LC10015 Galvaspan
KITCHEN FLOOR400mm Floor Joist CentresCovering - 2.0mm Polyflor Non-Slip Vinyl 100mm CoveFlooring - 15mm Compressed Fibre Cement(CFC)Joists - LC10015 Galvaspan
Wall Height2445
- Electrical Equipment ScheduleNo. Description Manufacturer Model Quantity
1 Salad Bar - 6 Mod - Storage Under / Glass Canopy BRAMS 6 Mod 82 Drinks Dispenser - 4 x 12 Litre PROMAC VL 448 43 Conveyor Toaster ROBAND TCR15 45 Rack - Conveyor Dishwasher ESWOOD ES100 18 Combi Oven - Electric BLUESEAL 20 tray - E20CSDW 18a Combi Oven - Electric BLUESEAL 14 tray - E14CSDW 19 Tilting Bratt Pan - Electric - 150 Litre GOLDSTEIN TPE-150 110 Deep Fryer - Electric - 3 Pan x 21 Litre GOLDSTEIN FRE-72D 111 Griddle - Electric GOLDSTEIN GPEDB-36 & SB36 212 Range - Electric - 8 Element GOLDSTEIN PE-8R-28 213 Hot Bain Marie - 6 Mod - Heated Storage Under / Sneeze Guard BRAMS 6 Mod 219a Planetary Mixer - 40 litre PARAMOUNT BM40 119b Planetary Mixer - 20 litre PARAMOUNT BM20 121 Semi Automatic Slicer BRICE GL Matic 122 Two Glass Door Chiller - 1120 Litres SKOPE B1200-2 322a Single Glass Door Chiller - 600 Litres SKOPE B600-2 232 Potato Peeler SAMMIC M10 136 Ice Cream Freezer - 183 Litre BAKER GLOBO 241 Microwave BONN MV 1000 1
BUG Electronic Bug Killer - 2 x 20W INSECT-O-CUTOR 14614 5
- Fire Services ScheduleNo. Description Quantity34 9.0Kg Fire Extinguisher - AB(E) 335 Fire Blanket 3
Handrail ScheduleTwin Rail Horizontal Handrails - as shown on floor plan
Manufacturing Structural Members
Description Member SizeBack to
BackSkid Beams - Perimeter Chasis 200PFC 2850Skid beams c/w retractablelifters
200PFC 2000
Rail System 200UB22.3Paired Beams C20020Paired Beams C30030 Stiffened
& Cambered
Rainwater GoodsDescription Quantity
Dropper only, for 100 x 75mm Downpipe 36
Sales Door Schedule
No. Panel Height WidthHandleType Hardware Set Closer
PanicBar
C/BJamb
TimberJamb Security Quantity Comments
D1 Standard : Hollow Core MC 2040 1840 Lever Entrance Yes No Yes No 3 E/E SealsD2 Standard : Hollow Core MC 2040 1740 Lever Entrance Yes No Yes No 1 E/E SealsD3 Standard : Hollow Core MC 2040 820 Standard Entrance No No Yes No 1 E/E SealsD4 Half Glass : Solid Core 2040 920 Lever Passage Yes No No Yes 2D5 Half Glass : Hollow Core 2040 920 Lever Entrance No No No Yes 2D6 Standard : Coldroom Panel Door 1900 800 Coolroom Furniture Yes No 3 Chillers - Supplied and installed by third party.D7 Standard : Freezer Panel Door 1900 800 Coolroom Furniture Yes No 3 Freezer - Supplied and installed by third party.O3 Opening Only 2040 1837 Yes No 3
Rev Description Date ByA Issed for Review 04.09.12 RA
FREEZER FLOOR - 100mm panel type c/w 15mm CFC,epoxy coated to give a water resistant surface with 3mmAli. Checker Plate over.COLDROOM FLOOR - 100mm panel type c/w 15mm CFC,epoxy coated to give a water resistant surface with 3mmAli. Checker Plate over.
NOTE: Floors flush to Hallway FFL
Stainless Steel BenchesNo. Description Quantity6a Dish Return c/w Scraps Hole / Chute (1400 x 2825 x 2900) (300 high
Splashback with 600 high wall cover)1
6b Dishwash Exit - 1500 x 700 (300 high Splashback with 600 high wallcover)
1
7a Prep Bench - Meat 01 x 2700w (300 high Splashback) 17b Prep Bench - Meat 02 x 4200w (300 high Splashback) 17c Prep Bench - Bakery 01 x 3200w (300 high Splashback) 17h Mobile Bench - Meat x 1200w (No Splashback) 17j Mobile Bench - Vege x 1200w (No Splashback) 114 Mobile Bench - Diner x 1800w x 750d x 900h (No Splashback) 515a Beverage Bench x 2850w (600 high Splashback) Splashback to LH side 115b Beverage Bench x 2900w (600 high Splashback) 116 Prep Bench - Cooking x 2900w (300 high Splashback) 116a Prep Bench - Cooking - Shelf x 2900w 133 Infill Bench - 450w 750d (300 high Splashback) 1
ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
CarmichaelQLD
Adani Mining Pty. Ltd.120842G
12.0 x 6.0m Office
- Drawing ListSheet
Number Sheet NameCurrentRevision
00 Title Page01 Floor Plan02 Elevations06 Sales Schedules
2
PE
DSB
POE
22 2
2
2
22 2 dpdp
dpdp
2
103
203
A
1 2
B
x
D12040
920
x
W11208900
300
AFFL
300
AFFL
1200
AFF
L
FE
82 2875 86 8875 82
8228
3616
428
3682
12000
6000
C
C30030 Paired Beams
x
D22040
920
x
D22040
920
x
W11208900
x
W11208900
x
W11208900
x
W11208900x
W11208900 x
W11208900
M1
M1
M2
M2
300 AFFL
300 AFFL
300 AFFL
300 AFFL
300
AFFL
300 AFFL
OFFICE
RECEPTIONOFFICE
OPEN OFFICE
4 4 4 4 4 4
1
2
3 3
1
4
2
3 3
1
2
1
2
4
2
1
33
3 3
2
1 1
2
2
1
300
AFFL
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
CarmichaelQLD
1 : 50
22/0
8/20
12 2
:05:
21 P
M
Adani Mining Pty. Ltd.12.0 x 6.0m Office
TK
RA
120842G -01
21.08.12
Floor Plan C2
5
Notes
1 : 50
Floor Plan1
Item ListD1 2040 x 920 External Door - Standard : Hollow Core MCD2 2040 x 920 Internal Door - Standard : Hollow Core
W1 900 x 1208 Sliding Glass Window - Grey Glass
M1 2.66kW R/C Split System Air ConditionerM2 5.05kW R/C Split System Air Conditioner
Rev Description Date By
1 Swivel Chair2 1200 x 600 Desk c/w Drawer3 PVC Stacker chair4 4 Drawer Filing Cabinet - By Othersdp Dropper only, for 100 x 75mm DownpipeFE Fire Extinguisher 9.0kg - AB(E)
- Fire fighting equipment supplied & installed by others.
- Plans are current at time of issue, are indicative only, and are subject tochange at any time without notice.
EXIT
240V Smoke detector
Distribution Switchboard
External light18W Single Vandalite
36w Single fluorescent light
15amp Single GPO.10amp Double GPO10amp Single GPO
36w Single fluorescent light - IP65 rated
36w Double fluorescent light
10amp GPO - IPX5 rated
Comms. - Draw wire only
Light switchTwo-way light switch
Photo electric light switchSpot light
'F' Type television outlet
Oyster light
Light switch - IPX5 rated
20amp Single GPO
Emergency exit lightOyster Light - 11W Round Fluro
36w Emergency back-up fluorescent light
POE - Point Of Entry
- Indicates floor mounting- Indicates ceiling mounting
DSB
IPX5
IPX5
WP
PE
Symbol Legend
2
Isolation Switch
PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point
ALL FURNITURE OPTIONED
FFL
0
Ceiling
2445
GL
-600
12
FFL
0
Ceiling
2445
GL
-600
1 2A B C
ABC
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
CarmichaelQLD
1 : 75
22/0
8/20
12 2
:05:
30 P
M
Adani Mining Pty. Ltd.12.0 x 6.0m Office
TK
RA
120842G -02
21.08.12
Elevations C2
5
1 : 75
Elevation AA
1 : 75
Elevation BB
Rev Description Date By
1 : 75
Elevation D1
1 : 75
Elevation C2
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
CarmichaelQLD
22/0
8/20
12 2
:05:
31 P
M
Adani Mining Pty. Ltd.12.0 x 6.0m Office
TK
RA
120842G -06
21.08.12
Sales Schedules C2
5
Sales Window Schedule
No. Type Glazing Height WidthSill
Height Quantity CommentsW1 Sliding XO Grey Glass 900 1208 1200 7 c/w Curtains
Sales Roof Structure ScheduleRoof Structure Comments
2° End to End RoofC2 - SDEK/PLY LC7512 - 611 - (3.0 & 3.5)611mm Ceiling Joist CentresCeiling Joist - LC7512 GalvaspanInsulation - R2.3 Foil Backed Blanket - 95mmLining - Internal - 3.6mm Polyester CoatedPlywoodPurlins - C7510 / LC7512 GalvaspanRoof - 0.42mm BMT Superdek Roofing
- Wall ScheduleWall Structure Comments
External Wall611mm Stud CentresCladding External - Colorbond Maxirib -"Headland"
Lower firstsheet
Cladding External - Colorbond Maxirib -"Paperbark"
Upper Sheets
Framing - 75 x 1.0mm Hi-Ten TruecoreFraming - 75x1.0mm Hi-Ten SteelInsulation - R2.9 Batts - 75mmLining - Internal - 3.6mm Polyester CoatedPlywoodThermal Break between Framing and CladdingPly Internal Wall611mm Stud CentresFraming - 75 x 1.0mm Hi-Ten TruecoreLining - Internal - 3.6mm Polyester CoatedPlywood
* Plumbing FixturesNo. Description Quantity Commentsdp Dropper only, for 100 x 75mm Downpipe 4
Lighting Fixtures Quantity2x36W Fluro - Bare 8Single Vandalite - Wall Mounted 1Switch - Std 1
- Electrical FixturesDescription Quantity
1x15amp GPO AC 42x10amp GPO 10Photo Electric Cell 1Switchboard 1- Furniture
No. Description Quantity Comments1 Swivel Chair 82 1200 x 600 Desk c/w Drawer 83 PVC Stacker chair 84 4 Drawer Filing Cabinet - By Others 8
Sales Mechanical EquipmentNo. Supplier Description QuantityM1 TECO 2.66kW R/C Split System Air Conditioner 2M2 TECO 5.05kW R/C Split System Air Conditioner 2
- Floor Structure ScheduleFloor Structure Comments
Floor600mm Floor Joist CentresCovering - 1.5mm Polyflor XL VinylFlooring - 17mm F11 T&G PlywoodInsulation - Under Floor - 15mm FoilboardJoists - LC7512 Galvaspan
Wall Height2445
- Fire Services ScheduleNo. Description QuantityFE 9.0Kg Fire Extinguisher - AB(E) 1
Manufacturing Structural Members
DescriptionMember
SizeBack to
BackSkid Beams c/w RetractableLifters
150PFC 2000
Paired Beams C30030
Sales Door Schedule
No. Panel Height WidthHandleType
HardwareSet Closer
PanicBar
C/BJamb
TimberJamb Security Quantity Comments
D1 Standard : Hollow Core MC 2040 920 Lever Entrance Yes No Yes No 1 E/E SealsD2 Standard : Hollow Core 2040 920 Lever Entrance No No Yes No 2
Rev Description Date By
ALL FURNITURE OPTIONED
OPTION
ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
Carmichael ProjectQLD
Adani Mining Pty. Ltd.120842H
12.0 x 3.0m Ablution Block
- Drawing ListSheet
Number Sheet NameCurrentRevision
00 Title Page01 Floor Plan02 Elevations05 Sales Schedules
View indicative only
DSB
PO
EPE
dp dpdp
WP WPfw fw
fw
103
203
A
1 2
Bx
D12040
820
6350 86 5400
1400
AFF
L
6
82 11837 82
8228
3782
12000
3000
HWS
2211
3 3
x
D22040
820
2 21 1
33
4
1439 86 900 62 870 62 870 86 945 86 945 945 86 945 86 870 62 870 62 1475
1337
1500
937
1900
5
5
5
5
5
x
W1750350x
W1750350 x
W1750350 x
W1750350x
W1750350 x
W1750350
x
W1750350 x
W1750350
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
Carmichael ProjectQLD
1 : 50
22/0
8/20
12 1
:28:
41 P
M
Adani Mining Pty. Ltd.12.0 x 3.0m Ablution Block
TK
RA
120842H -01
21.08.12
Floor Plan C2
10a
- Fire fighting equipment supplied & installed by others.- Plans are current at time of issue, are indicative only, and are subject to
change at any time without notice.
Notes1 WC Cubicle c/w toilet roll holder2 Shower enclosure c/w bench seat & coat hooks3 S/S Handbasin c/w mirror over4 600mm Wall mounted S/S urinal5 Locker - 4 Bank 300 Wide - 1 Tier6 9.0Kg Fire Extinguisher - AB(E)dp Dropper only, for 100 x 75mm Downpipefw Floor WasteHWS Rheem Heat Pump 325 Litre/6kW -MPi - mounted externallyItem List
D1 2040 x 820 External Door - Standard : Hollow Core MCD2 2040 x 820 External Door - Standard : Hollow Core MCW1 350 x 750 Sliding Glass Window - Obscure Glass
Rev Description Date By
240V Smoke detector
Distribution Switchboard
External light18W Single Vandalite
36w Single fluorescent light
15amp Single GPO.10amp Double GPO10amp Single GPO
36w Single fluorescent light - IP65 rated
36w Double fluorescent light
10amp GPO - IPX5 rated
Comms. - Draw wire only
Light switchTwo-way light switch
Photo electric light switch
Spot light
'F' Type television outlet
Oyster light
Light switch - IPX5 rated
20amp Single GPO
Emergency exit light
Oyster Light - 11W Round Fluro
36w Emergency back-up fluorescent light
POE - Point Of Entry
- Indicates floor mounting- Indicates ceiling mounting
IPX5
IPX5
WP
Symbol Legend
Isolation Switch
PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point
OPTIONAL
FFL
0
Ceiling
2445
GL
-600
12
FFL
0
Ceiling
2445
GL
-600
1 2A B
AB
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
Carmichael ProjectQLD
1 : 75
22/0
8/20
12 1
:28:
49 P
M
Adani Mining Pty. Ltd.12.0 x 3.0m Ablution Block
TK
RA
120842H -02
21.08.12
Elevations C2
10a
1 : 75
Elevation AA
1 : 75
Elevation BB
2° End to End Roof
Aluminium Framed Windows
Panelrib External Cladding
Metal Clad External Doors
150 PFC Skid Beams
Rev Description Date By
1 : 75
Elevation D1
1 : 75
Elevation C2
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
Carmichael ProjectQLD
22/0
8/20
12 1
:28:
53 P
M
Adani Mining Pty. Ltd.12.0 x 3.0m Ablution Block
TK
RA
120842H -05
21.08.12
Sales Schedules C2
10a
Sales Window Schedule
No. Type Glazing Height WidthSill
Height Quantity CommentsW1 PVO Obscure Glass 350 750 1960 8
Sales Roof Structure ScheduleRoof Structure Comments
2° End to End RoofC2 - SDEK/PLY LC7512 - 611 - (3.0 & 3.5)611mm Ceiling Joist CentresCeiling Joist - LC7512 GalvaspanInsulation - R2.3 Foil Backed Blanket - 95mmLining - Internal - 3.6mm Polyester CoatedPlywoodPurlins - C7510 / LC7512 GalvaspanRoof - 0.42mm BMT Superdek Roofing
- Wall ScheduleWall Structure Comments
External Wall611mm Stud CentresCladding External - Colorbond Maxirib -"Headland"
Lower firstsheet
Cladding External - Colorbond Maxirib -"Paperbark"
Upper Sheets
Framing - 75 x 1.0mm Hi-Ten TruecoreLining - Internal - 3.6mm Polyester CoatedPlywoodPly Internal Wall611mm Stud CentresFraming - 75 x 1.0mm Hi-Ten TruecoreLining - Internal - 3.6mm Polyester CoatedPlywood
* Plumbing FixturesNo. Description Quantity Comments
1 WC Cubicle c/w toilet roll holder 42 Shower enclosure c/w bench seat & coat hooks 43 S/S Handbasin c/w mirror over 44 600mm Wall mounted S/S urinal 1dp Dropper only, for 100 x 75mm Downpipe 3fw Floor Waste 3
HWS Rheem Heat Pump 325 Litre/6kW -MPi -mounted externally
1
Lighting Fixtures Quantity1x36W Fluro - Bare 21x36W Fluro - IP65 2Single Vandalite - Wall Mounted 2Switch - Std 2
- Electrical FixturesDescription Quantity
1x10amp GPO 2Photo Electric Cell 1Switchboard 1
- FurnitureNo. Description Quantity Comments
5 Locker - 4 Bank 300 Wide - 1 Tier 5
- Floor Structure ScheduleFloor Structure Comments
Floor600mm Floor Joist CentresCovering - 1.5mm Polyflor XL Vinyl 100mm Cove
thoughoutFlooring - 17mm F11 T&G PlywoodJoists - LC7512 Galvaspan
Wall Height2445
- Fire Services ScheduleNo. Description Quantity
6 9.0Kg Fire Extinguisher - AB(E) 1
Manufacturing Structural Members
DescriptionMember
SizeBack to
BackSkid Beams c/w RetractableLifters
150PFC 2000
Rainwater GoodsDescription Quantity
Dropper only, for 100 x 75mm Downpipe 3
Sales Door Schedule
No. Panel Height WidthHandleType
HardwareSet Closer
PanicBar
C/BJamb
TimberJamb Security Quantity Comments
D1 Standard : Hollow Core MC 2040 820 Standard Entrance No No Yes No 1D2 Standard : Hollow Core MC 2040 820 Standard Entrance No No Yes No 1
Rev Description Date By
OPTIONAL
ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
Carmichael ProjectQLD
Adani Mining Pty. Ltd.120842J
12.0 x 3.0m Linen Store
- Drawing ListSheet
Number Sheet NameCurrentRevision
00 Title Page01 Floor Plan02 Elevations06 Sales Schedules
View indicative only
2
DSB
POE
PE
dp
dp
103
203
A
1 2
Bx
D12040
920
x
W11208900
300
AFFL
300
AFFL
1200
AFF
L
2
82 11837 82
8228
3782
12000
3000
1
1
1
1
2.8m
10.8m
4.8m
2.8m
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
Carmichael ProjectQLD
1 : 50
22/0
8/20
12 1
:13:
00 P
M
Adani Mining Pty. Ltd.12.0 x 3.0m Linen Store
TK
RA
120842J -01
20.08.12
Floor Plan C2
10a
- Fire fighting equipment supplied & installed by others.
- Plans are current at time of issue, are indicative only, and are subject tochange at any time without notice.
Notes
1 : 50
Floor Plan1
1 3 Tier shelving2 9.0Kg Fire Extinguisher - AB(E)dp Dropper only, for 100 x 75mm Downpipe
Item ListD1 2040 x 920 External Door - Standard : Hollow Core MC
W1 900 x 1208 Sliding Glass Window - Grey Glass
Rev Description Date By
EXIT
240V Smoke detector
Distribution Switchboard
External light18W Single Vandalite
36w Single fluorescent light
15amp Single GPO.10amp Double GPO10amp Single GPO
36w Single fluorescent light - IP65 rated
36w Double fluorescent light
10amp GPO - IPX5 rated
Comms. - Draw wire only
Light switchTwo-way light switch
Photo electric light switchSpot light
'F' Type television outlet
Oyster light
Light switch - IPX5 rated
20amp Single GPO
Emergency exit lightOyster Light - 11W Round Fluro
36w Emergency back-up fluorescent light
POE - Point Of Entry
- Indicates floor mounting- Indicates ceiling mounting
DSB
IPX5
IPX5
WP
PE
Symbol Legend
2
Isolation Switch
PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point
OPTION
FFL
0
Ceiling
2445
GL
-600
12
FFL
0
Ceiling
2445
GL
-600
1 2A B
AB
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
Carmichael ProjectQLD
1 : 75
22/0
8/20
12 1
:13:
05 P
M
Adani Mining Pty. Ltd.12.0 x 3.0m Linen Store
TK
RA
120842J -02
20.08.12
Elevations C2
10a
1 : 75
Elevation AA
1 : 75
Elevation BB
2° Skillion RoofAluminium Framed Windows
Panelrib External Cladding
Metal Clad External Doors
150 PFC Skid Beams
Rev Description Date By
1 : 75
Elevation D1
1 : 75
Elevation C2
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
Carmichael ProjectQLD
22/0
8/20
12 1
:13:
07 P
M
Adani Mining Pty. Ltd.12.0 x 3.0m Linen Store
TK
RA
120842J -06
20.08.12
Sales Schedules C2
10a
Sales Window Schedule
No. Type Glazing Height WidthSill
Height Quantity CommentsW1 Sliding XO Grey Glass 900 1208 1200 1 c/w Curtains
Sales Roof Structure ScheduleRoof Structure Comments
2° End to End RoofC2 - SDEK/PLY LC7512 - 611 - (3.0 & 3.5)611mm Ceiling Joist CentresCeiling Joist - LC7512 GalvaspanInsulation - R2.3 Foil Backed Blanket - 95mmLining - Internal - 3.6mm Polyester CoatedPlywoodPurlins - C7510 / LC7512 GalvaspanRoof - 0.42mm BMT Superdek Roofing
- Wall ScheduleWall Structure Comments
External Wall611mm Stud CentresCladding External - Colorbond Maxirib -"Headland"
Lower firstsheet
Cladding External - Colorbond Maxirib -"Paperbark"
Upper Sheets
Framing - 75 x 1.0mm Hi-Ten TruecoreLining - Internal - 3.6mm Polyester CoatedPlywood
* Plumbing FixturesNo. Description Quantity Commentsdp Dropper only, for 100 x 75mm Downpipe 2
Lighting Fixtures Quantity2x36W Fluro - Bare 4Single Vandalite - Wall Mounted 1Switch - Std 1
- Electrical FixturesDescription Quantity
1x10amp GPO 12x10amp GPO 1Photo Electric Cell 1Switchboard 1
- FurnitureNo. Description Quantity Comments
1 3 Tier shelving 4
- Floor Structure ScheduleFloor Structure Comments
Floor600mm Floor Joist CentresCovering - 1.5mm Polyflor XL Vinyl 100mm Cove
thoughoutFlooring - 17mm F11 T&G PlywoodJoists - LC7512 Galvaspan
Wall Height2445
- Fire Services ScheduleNo. Description Quantity
2 9.0Kg Fire Extinguisher - AB(E) 1
Manufacturing Structural Members
DescriptionMember
SizeBack to
BackSkid Beams c/w RetractableLifters
150PFC 2000
Sales Door Schedule
No. Panel Height WidthHandleType
HardwareSet Closer
PanicBar
C/BJamb
TimberJamb Security Quantity Comments
D1 Standard : Hollow Core MC 2040 920 Lever Entrance No No Yes No 1 E/E Seals
Rev Description Date By
OPTION
OPTION
ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
QLDATCO Structures & Logistics Pty. Ltd.
WGM-1212-H-C2
12.0 x 12.0m Gymnasium
- Drawing ListSheet
Number Sheet NameCurrentRevision
00 Title Page01 Floor Plan02 Elevations06 Sales Schedules
DSB
POEPE
DSB
PO
E
DSB
PO
E
DSB
PO
E
DSB
PO
E 2
22
22
22
2
TV
dpdp
dpdpdp
dpdp
dp
103
203
A
1 2
B
x
D12040
1840 300
AFFL
1200
AFF
L
1
82 11837 8282
1183
782
1200012
000
C
C20020 Paired Beams
D
E
Post
Post
Post
x
W11208900
x
W11208900
x
W11208900
M1
M1
x
W11208900
x
W11208900
M1
M1
x
W11208900
x
W11208900
M1
M1
x
W11208900
x
W11208900
M1
M1
x
W11208900 x
W11208900
x
W11208900 x
W11208900
300 AFFL
300 AFFL
300 AFFL
300 AFFL
300 AFFL
300 AFFL
300 AFFL
300 AFFL
300
AFFL
2 2
Wat
er S
uppl
y
Wat
er S
uppl
y
33 3
3
3
3
MIRRORunder A/C
MIRRORunder A/C
MIRRORunder A/C
MIRRORunder A/C
4
4
4
57
8
9
10
6
9
12
11
13
8
9 14
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
QLD1 : 75
2/08
/201
2 2:
08:2
6 P
M
ATCO Structures & Logistics Pty. Ltd.12.0 x 12.0m Gymnasium
TK
RA
WGM-1212-H-C2 -01
14.04.12
Floor Plan C2
9b
Notes
Item ListD1 2040 x 1840 External Double Door - Standard : Hollow Core MC
W1 900 x 1208 Sliding Glass Window - Grey Glass
M1 5.0kW R/C Split System Air Conditioner - Inverter
Rev Description Date By
- Fire fighting equipment supplied & installed by others.
- Plans are current at time of issue, are indicative only and are subject tochange at any time without notice.
Vision 9700 HRC Tread Mill4 3
Olympic Bench Press Prone5 1
Vision 6850 XT Cross Trainer6 1
Smith Machine Linear7 1
Adjustable Incline Bench 0-90°8 2
Vision 3800 U/R Exercise Bike9 3
Concept 2 Model D Rowing machine10 1
Elite Sschwinn 780 Multistation11 1
Abdominal Ladder12 1
Heavy Bag & Speed Ball & Stand13 1
1 to 25kg Dumbell Set & Rack14 1
Items not shown, but included:Olympic EZ Curl Bar & WeightsOlympic 7' Straight Bars & CollarsLeather Weight Lifting Belt200kg of Olympic Weights &Weight Tree
Equipment
Plumbing - Water Inlet c/w Line Strainer1 9.0Kg Fire Extinguisher - AB(E)2 Water Cooler - Zip Freestanding EMBCF 60 - Mains Connected3 1800 x 900 Mirrordp Dropper only, for 100 x 75mm Downpipe
EXIT
240V Smoke detector
Distribution Switchboard
External light18W Single Vandalite
36w Single fluorescent light
15amp Single GPO.10amp Double GPO10amp Single GPO
36w Single fluorescent light - IP65 rated
36w Double fluorescent light
10amp GPO - IPX5 rated
Comms. - Draw wire only
Light switchTwo-way light switch
Photo electric light switchSpot light
'F' Type television outlet
Oyster light
Light switch - IPX5 rated
20amp Single GPO
Emergency exit lightOyster Light - 11W Round Fluro
36w Emergency back-up fluorescent light
POE - Point Of Entry
- Indicates floor mounting- Indicates ceiling mounting
DSB
IPX5
IPX5
WP
PE
Symbol Legend
2
Isolation Switch
PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point
FFL
0
Ceiling
2745
GL
-600
12
FFL
0
Ceiling
2745
GL
-600
1 2A B C D E
ABCDE
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
QLD1 : 75
2/08
/201
2 2:
08:3
6 P
M
ATCO Structures & Logistics Pty. Ltd.12.0 x 12.0m Gymnasium
TK
RA
WGM-1212-H-C2 -02
14.04.12
Elevations C2
9b
1 : 75
Elevation AA
1 : 75
Elevation BB
Rev Description Date By
1 : 75
Elevation D1
1 : 75
Elevation C2
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
QLD
2/08
/201
2 2:
08:3
7 P
M
ATCO Structures & Logistics Pty. Ltd.12.0 x 12.0m Gymnasium
TK
RA
WGM-1212-H-C2 -06
14.04.12
Sales Schedules C2
9b
Sales Window Schedule
No. Type Glazing Height WidthSill
Height Quantity CommentsW1 Sliding XO Grey Glass 900 1208 1000 13 c/w Curtains
* Plumbing FixturesNo. Description Quantity Comments
Plumbing - Water Inlet c/w Line Strainer 12 Water Cooler - Zip Freestanding EMBCF 60 -
Mains Connected2
dp Dropper only, for 100 x 75mm Downpipe 8
Lighting Fixtures Quantity2x36W Fluro - Bare 17Single Vandalite - Wall Mounted 1Switch - Std 1
- Electrical FixturesDescription Quantity
1x10amp GPO - Ceiling Mounted 11x10amp GPO AC 22x10amp GPO 8Isolation Switch - AC 8Photo Electric Cell 1Switchboard 5TV - Ceiling Mtd 1
- FurnitureNo. Description Quantity Comments
3 1800 x 900 Mirror 6
Sales Mechanical EquipmentNo. Supplier Description QuantityM1 DAIKIN 5.0kW R/C Split System Air Conditioner -
Inverter8
- Floor Structure ScheduleFloor Structure Comments
Floor300mm Floor Joist CentresCovering - Planet Supreme Direct Stick CarpetFlooring - 17mm F11 T&G Plywood Two LayersJoists - LC7512 Galvaspan
Wall Height2745
- Fire Services ScheduleNo. Description Quantity
1 9.0Kg Fire Extinguisher - AB(E) 1
Manufacturing Structural Members
DescriptionMember
SizeBack to
BackSkid Beams c/w RetractableLifters
150PFC 2000
Paired Beams C20020
Sales Door Schedule
No. Panel Height WidthHandleType
HardwareSet Closer
PanicBar
C/BJamb
TimberJamb Security Quantity Comments
D1 Standard : Hollow Core MC 2040 1840 Lever Entrance Yes No Yes No 1 E/E Seals and Closerto each leaf.
Rev Description Date By
Vision 9700 HRC Tread Mill4 3
Olympic Bench Press Prone5 1
Vision 6850 XT Cross Trainer6 1
Smith Machine Linear7 1
Adjustable Incline Bench 0-90°8 2
Vision 3800 U/R Exercise Bike9 3
Concept 2 Model D Rowing machine10 1
Elite Sschwinn 780 Multistation11 1
Abdominal Ladder12 1
Heavy Bag & Speed Ball & Stand13 1
1 to 25kg Dumbell Set & Rack14 1
Items not shown, but included:Olympic EZ Curl Bar & WeightsOlympic 7' Straight Bars & CollarsLeather Weight Lifting Belt200kg of Olympic Weights &Weight Tree
Equipment
- Wall ScheduleWall Structure Comments
External Wall611mm Stud CentresCladding External - Colorbond Maxirib -"Headland"
Lower firstsheet
Cladding External - Colorbond Maxirib -"Paperbark"
Upper Sheets
Framing - 75 x 1.0mm Hi-Ten TruecoreFraming - 75x1.0mm Hi-Ten SteelInsulation - R2.9 Batts - 75mmLining - Internal - 3.6mm Polyester CoatedPlywoodThermal Break between Framing and Cladding
Sales Roof Structure ScheduleRoof Structure Comments
2° End to End RoofC2 - SDEK/PLY LC7512 - 611 - (3.0 & 3.5)611mm Ceiling Joist CentresCeiling Joist - LC7512 GalvaspanInsulation - R2.3 Foil Backed Blanket - 95mmLining - Internal - 3.6mm Polyester CoatedPlywoodPurlins - C7510 / LC7512 GalvaspanRoof - 0.42mm BMT Superdek Roofing
ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
QLDATCO Structures & Logistics Pty. Ltd.
WRC-1812-H-C2
18.0 x 12.0m Recreation Centre
- Drawing ListSheet
Number Sheet NameCurrentRevision
00 Title Page01 Floor Plan02 Elevations06 Sales Schedules
fw
fw
DSB
POE
DSB
POE
DSB
POE
DSB
POE
DSB
POE
DSB
POE
22
22
2
2
22
22
2
22
2 2
2 2 2 2
2
2TV
EXI
T
EXIT
EXIT
fw
dp dp dp dp dp dp
dp dp dp dp dp dpPEPE PE
103
203
A
1 5
82 17837 82
8211
837
82
18000
1200
0
2 3 4 76
B
x
W11208900
x
W11208900
x
W11208900
x
W11208900
M1
M1
C20
020
Pai
red
Bea
ms
C20
020
Pai
red
Bea
ms
C20
020
Pai
red
Bea
ms
C20
020
Pai
red
Bea
ms
Post Post Post
x
W11208900 x
W11208900 x
W11208900 x
W11208900
M1 M1 M1 M1
M1
x
W11208900
M1
x
W21208900
M1
M1
x
W11208900
x
W21208900
x
D12040
1840
x
D22040
920
x
D22040
920
x
D22040
920
x
D42040
920
x
D32040
920
x
RW11208900
x
RW11208900
x
RW11208900
12
12M1
11
10a
10b
8
811
7
1920
5
5
5
5
5
15 15
4
1
4
44
4
4
4
4
4
4 214
14
M1
22
1200 AFFL
300 AFFL
1400 AFFL22
00 A
FFL
1200
AFF
L
300
AFFL
1400 AFFL
300
AFFL
1700 AFFL
1200 AFFL
1400 AFFL
300
AFFL
1200
AFF
L
1400 AFFL
1400 AFFL
1400 AFFL
300
AFFL
300
AFFL
1200
AFF
L1400 AFFL
1400 AFFL
1700 AFFL
1400 AFFL
1400 AFFL
1400 AFFL
1400 AFFL
1400 AFFL1400 AFFL
2200 AFFL
1400 AFFL300 AFFL
300
AFFL
2
2
55
5 5TYPICAL
13
9
18
6
300 AFFL
3
3
x
D12040
1840
2222
2222
Stacked A/C Motors
17
1400 AFFL1400 AFFL
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
QLD 1 : 100
2/08
/201
2 1:
53:2
3 P
M
ATCO Structures & Logistics Pty. Ltd.18.0 x 12.0m Recreation Centre
TK
RA
WRC-1812-H-C2 -01
14.04.12
Floor Plan C2
9b
Notes
1 : 100
Floor Plan1
Plumbing - Water Inlet c/w Line Strainer1 Television - LCD - 50" - 127cm2 9.0Kg Fire Extinguisher - AB(E)3 MANITOWOC - Ice Machine - S-450 on B400 Storage
Bin (173kg/24hr, 130kg holding capacity)4 Lounge Chair5 PVC Stacker chair6 1200 Dia. Melamine table7 Fridge - Single Door - 370 Litre - WRM3700WB8 1200x450 S/S insert sink9 7.5ltr Autoboiler
10a 600mm Wide Laminated benchtop c/w cupboards x2400. c/w 600 high SS Splashback
10b 600mm Wide Laminated benchtop c/w cupboards x1800. c/w 600 high SS Splashback
11 50Ltr Hot Water System - Internal c/w Safe Tray12 SKOPE Two Glass Door Chiller - B900-213 600mm Wide Laminated benchtop c/w cupboards & 2
sets of drawers.14 Dart Board15 Pool table c/w Cue Rack & pool Cues17 5 Tap Stainless Steel Fill Up Station - 3000mm long18 600mm (W) Melamine benchtop c/w steel legs19 Dishwasher20 Water Cooler - Zip Freestanding EMBCF 60 - Mains
Connected. SS Splashback.22 Wall mounted water connectiondp Dropper only, for 100 x 75mm Downpipefw Floor Waste
Item ListD1 2040 x 1840 External Double Door - Standard : Hollow Core MCD2 2040 x 920 External Door - Standard : Hollow Core MCD3 2040 x 920 Internal Door - Standard : Hollow CoreD4 2040 x 920 Internal Door - Standard : Hollow Core
RW1 900 x 1208 Roller Window ColorbondW1 900 x 1208 Sliding Glass Window - Grey GlassW2 900 x 1208 Sliding Glass Window - Grey Glass
M1 5.0kW R/C Split System Air Conditioner - Inverter
Rev Description Date By
- Fire fighting equipment supplied & installed by others.
- Plans are current at time of issue, are indicative only and are subject to changeat any time without notice.
- Any 3D views are to be regarded as indicative only.- Additional Draw Wires may be required subject to Client requirement
240V Smoke detector
Distribution Switchboard
External light18W Single Vandalite
36w Single fluorescent light
15amp Single GPO.10amp Double GPO10amp Single GPO
36w Single fluorescent light - IP65 rated
36w Double fluorescent light
10amp GPO - IPX5 rated
Comms. - Draw wire only
Light switchTwo-way light switch
Photo electric light switch
Spot light
'F' Type television outlet
Oyster light
Light switch - IPX5 rated
20amp Single GPO
Emergency exit light
Oyster Light - 11W Round Fluro
36w Emergency back-up fluorescent light
POE - Point Of Entry
- Indicates floor mounting- Indicates ceiling mounting
DSB
IPX5
IPX5
WP
EXIT
PE
Symbol Legend
2
Isolation Switch
PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point
FFL
0
Ceiling
2445
GL
-600
15 2347 6
FFL
0
Ceiling
2445
GL
-600
1 52 3 4 76A B
AB
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
QLD 1 : 100
2/08
/201
2 1:
53:4
5 P
M
ATCO Structures & Logistics Pty. Ltd.18.0 x 12.0m Recreation Centre
TK
RA
WRC-1812-H-C2 -02
14.04.12
Elevations C2
9b
1 : 100
Elevation AA
1 : 100
Elevation BB
Rev Description Date By
1 : 100
Elevation D1
1 : 100
Elevation C2
Panelrib External Cladding
2° End to End Roof Aluminium Framed Windows
Wall Mounted Air ConditionerMetal Clad External Doors
150PFC Skid Beams
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
QLD
2/08
/201
2 1:
53:4
6 P
M
ATCO Structures & Logistics Pty. Ltd.18.0 x 12.0m Recreation Centre
TK
RA
WRC-1812-H-C2 -06
14.04.12
Sales Schedules C2
9b
Sales Window Schedule
No. Type Glazing Height WidthSill
Height Quantity CommentsRW1 Roller Window Colorbond 900 1208 1100 3W1 Sliding XO Grey Glass 900 1208 1000 10 c/w CurtainsW2 Sliding XO Grey Glass 900 1208 1200 2 c/w Curtains
Sales Roof Structure ScheduleRoof Structure Comments
2° End to End RoofC2 - SDEK/PLY LC7512 - 611 - (3.0 & 3.5)611mm Ceiling Joist CentresCeiling Joist - LC7512 GalvaspanInsulation - R2.3 Foil Backed Blanket - 95mmLining - Internal - 3.6mm Polyester CoatedPlywoodPurlins - C7510 / LC7512 GalvaspanRoof - 0.42mm BMT Superdek Roofing
- Wall ScheduleWall Structure Comments
External Wall611mm Stud CentresCladding External - Colorbond Maxirib -"Headland"
Lower firstsheet
Cladding External - Colorbond Maxirib -"Paperbark"
Upper Sheets
Framing - 75 x 1.0mm Hi-Ten TruecoreFraming - 75x1.0mm Hi-Ten SteelInsulation - R2.9 Batts - 75mmLining - Internal - 3.6mm Polyester CoatedPlywoodThermal Break between Framing and CladdingPly Internal Wall611mm Stud CentresFraming - 75 x 1.0mm Hi-Ten TruecoreLining - Internal - 3.6mm Polyester CoatedPlywood
* Plumbing FixturesNo. Description Quantity Comments
Plumbing - Water Inlet c/w Line Strainer 18 1200x450 S/S insert sink 29 7.5ltr Autoboiler 111 50Ltr Hot Water System - Internal c/w Safe Tray 217 5 Tap Stainless Steel Fill Up Station - 3000mm
long1
20 Water Cooler - Zip Freestanding EMBCF 60 -Mains Connected. SS Splashback.
1
22 Wall mounted water connection 5dp Dropper only, for 100 x 75mm Downpipe 12fw Floor Waste 3
Lighting Fixtures Quantity2x36W Fluro - Bare 24Dart Board Light 2Exit - Ceiling Mount 3Pool Table Light - Ceiling Mounted 2Single Vandalite - Wall Mounted2 5Switch - Std 6
- Electrical FixturesDescription Quantity
1x10amp GPO 11x20amp GPO 22x10amp GPO 21Draw Wire 7Isolation Switch - AC 12Photo Electric Cell 3Switchboard 6TV Antenna Socket 1
- FurnitureNo. Description Quantity Comments
4 Lounge Chair 105 PVC Stacker chair 606 1200 Dia. Melamine table 1414 Dart Board 215 Pool table c/w Cue Rack & pool Cues 218 600mm (W) Melamine benchtop c/w steel legs 1 5875 long
- CupboardsNo. Description Quantity Comments10a 600mm Wide Laminated benchtop c/w cupboards
x 2400. c/w 600 high SS Splashback1
10b 600mm Wide Laminated benchtop c/w cupboardsx 1800. c/w 600 high SS Splashback
1
13 600mm Wide Laminated benchtop c/w cupboards& 2 sets of drawers.
1 Leg 1650 &Leg 4600
Sales Mechanical EquipmentNo. Supplier Description QuantityM1 DAIKIN 5.0kW R/C Split System Air Conditioner - Inverter 12
- Floor Structure ScheduleFloor Structure Comments
Floor480mm Floor Joist CentresCovering - 1.5mm Polyflor XL VinylCovering - 2.0mm Polyflor Non-Slip Vinyl Inside Bar Area
& Ice Roomonly. 100mmCove
Flooring - 17mm F11 T&G PlywoodJoists - LC7512 Galvaspan
Wall Height2445
- Electrical Equipment ScheduleNo. Description Quantity Comments
1 Television - LCD - 50" - 127cm 13 MANITOWOC - Ice Machine - S-450 on B400
Storage Bin (173kg/24hr, 130kg holding capacity)2
7 Fridge - Single Door - 370 Litre - WRM3700WB 112 SKOPE Two Glass Door Chiller - B900-2 219 Dishwasher 1
- Fire Services ScheduleNo. Description Quantity
2 9.0Kg Fire Extinguisher - AB(E) 3
Manufacturing Structural Members
DescriptionMember
SizeBack to
BackSkid Beams c/w RetractableLifters
150PFC 2000
Paired Beams C20020
Sales Door Schedule
No. Panel Height WidthHandleType
HardwareSet Closer
PanicBar
C/BJamb
TimberJamb Security Quantity Comments
D1 Standard : Hollow Core MC 2040 1840 Lever Entrance Yes No Yes No 2 E/E SealsD2 Standard : Hollow Core MC 2040 920 Lever Entrance Yes No Yes No 3 E/E SealsD3 Standard : Hollow Core 2040 920 Lever Entrance Yes No Yes No 1D4 Standard : Hollow Core 2040 920 Lever Entrance Yes No Yes No 1
Rev Description Date By
ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
Carmichael ProjectQLD
Adani Mining Pty. Ltd.120842D
12.0 x 3.0m Laundry
- Drawing ListSheet
Number Sheet NameCurrentRevision
00 Title Page01 Floor Plan02 Elevations05 Sales Schedules
View indicative only
2 2 2
fw fw fw
DSB
PO
EPE
dp dpdp
2
fw fw
103
203
A
1 2
Bx
D12040
820
x
W11208900 x
W11208900
x
W11208900x
W11208900
1
3 3 3
1
3 3
1
3
1173 2222 2222 2222 2222 1775
Tub Tub Tub
1400
AFF
L
1400
AFF
L
1400
AFF
L
82
4
1400
AFF
L
1400
AFF
L
1400
AFF
L
1400
AFF
L14
00 A
FFL
1400
AFF
L
M1
300
AFFL
1200
AFF
L
9
82 11837 82
8228
3782
12000
3000
77 7 7 7 7
5 6 5 6 5 6
HWS
1400
AFF
L
1
3 3 3
1
1400
AFF
L
5 6 5
1400
AFF
L
7
1400
AFF
L
7
1400
AFF
L
7
3
1400
AFF
L
5
1400
AFF
L
7
650 803 803 803 803 803 2500 803 803 803 2263
M1
Tub Tub
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
Carmichael ProjectQLD
1 : 50
24/0
8/20
12 1
1:42
:45
AM
Adani Mining Pty. Ltd.12.0 x 3.0m Laundry
TK
RA
120842D -01
21.08.12
Floor Plan C2
10a
- Fire fighting equipment supplied & installed by others.- HWS (Capacity: 6 washing machine loads per hour @ 20 litres per load.- Floor Drains: One fixture per Floor Waste, all other fixtures discharge
direct to waste lines.- Plans are current at time of issue, are indicative only, and are subject to
change at any time without notice.
Notes1 Standard Laundry Unit - 45 Litre, Splashback & Wall Taps2 Water Cooler - Zip Freestanding EMBCF 60 - Mains Connected3 Washing Machine Taps4 1400 x 600 Melamine Table c/w Legs5 SPEED QUEEN 6.5kg Washing Machine6 SPEED QUEEN 6.5kg Washing Machine c/w Discharge Stand Pipe7 SPEED QUEEN 9kg Dryer8 ROBIN HOOD Ironing Centre & Hard Wired Steam Iron9 9.0Kg Fire Extinguisher - AB(E)dp Dropper only, for 100 x 75mm Downpipefw Floor WasteHWS Rheem Heat Pump 325 Litre/3.6kW -MPi - mounted externally
Item ListD1 2040 x 820 External Door - Standard : Hollow Core MC
W1 900 x 1208 Sliding Glass Window - Grey Glass
M1 Wall Mounted Exhaust Fan
Rev Description Date By
240V Smoke detector
Distribution Switchboard
External light18W Single Vandalite
36w Single fluorescent light
15amp Single GPO.10amp Double GPO10amp Single GPO
36w Single fluorescent light - IP65 rated
36w Double fluorescent light
10amp GPO - IPX5 rated
Comms. - Draw wire only
Light switchTwo-way light switch
Photo electric light switch
Spot light
'F' Type television outlet
Oyster light
Light switch - IPX5 rated
20amp Single GPO
Emergency exit light
Oyster Light - 11W Round Fluro
36w Emergency back-up fluorescent light
POE - Point Of Entry
- Indicates floor mounting- Indicates ceiling mounting
DSB
IPX5
IPX5
WP
EXIT
PE
Symbol Legend
2
Isolation Switch
PLUMBING - Water Inlet PointPLUMBING - Waste Manifold Outlet Point
OPTION
OPTIONOPTIONOPTIONOPTIONOPTION
FFL
0
Ceiling
2445
GL
-600
12
FFL
0
Ceiling
2445
GL
-600
1 2A B
AB
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
Carmichael ProjectQLD
1 : 75
24/0
8/20
12 1
1:42
:54
AM
Adani Mining Pty. Ltd.12.0 x 3.0m Laundry
TK
RA
120842D -02
21.08.12
Elevations C2
10a
1 : 75
Elevation AA
1 : 75
Elevation BB
2° Skillion Roof
Aluminium Framed Windows
Panelrib External Cladding
Metal Clad External Doors
150 PFC Skid Beams
Rev Description Date By
1 : 75
Elevation D1
1 : 75
Elevation C2
THIS DRAWINGREMAINS THEPROPERTY OF
ATCO STRUCTURESPTY. LTD. IT MAY NOTBE REPRODUCED ORCOPIED WHOLE OR IN
PART WITHOUTWRITTEN AUTHORITY
QUALITYCERTIFIED TO
AS/NZS ISO9001:2008
BYSCI-QUAL
INTERNATIONALREGN No. 531
DATE
SCALE
DRAWN
CHECKED
TITLE
DRAWING NUMBER
PROJECT No. DESIGN WIND LOAD
REVISION SHEET SIZE
A3ATCO STRUCTURES & LOGISTICS PTY. LTD.149-151 MAGNESIUM DRIVE, CRESTMEAD, QLD 4132P.O. BOX 1171, BROWNS PLAINS BC, QLD 4118E-mail: [email protected]
PHONE:FAX:
ABN:
(07) 3412 8600(07) 3803 0175
71 083 902 309
NCC BUILDING CLASS
Carmichael ProjectQLD
24/0
8/20
12 1
1:42
:58
AM
Adani Mining Pty. Ltd.12.0 x 3.0m Laundry
TK
RA
120842D -05
21.08.12
Sales Schedules C2
10a
Sales Window Schedule
No. Type Glazing Height WidthSill
Height Quantity CommentsW1 Sliding XO Grey Glass 900 1208 1200 4 C/w Curtains
Sales Roof Structure ScheduleRoof Structure Comments
2° End to End RoofC2 - SDEK/PLY LC7512 - 611 - (3.0 & 3.5)611mm Ceiling Joist CentresCeiling Joist - LC7512 GalvaspanInsulation - R2.3 Foil Backed Blanket - 95mmLining - Internal - 3.6mm Polyester CoatedPlywoodPurlins - C7510 / LC7512 GalvaspanRoof - 0.42mm BMT Superdek Roofing
- Wall ScheduleWall Structure Comments
External Wall611mm Stud CentresCladding External - Colorbond Maxirib -"Headland"
Lower firstsheet
Cladding External - Colorbond Maxirib -"Paperbark"
Upper Sheets
Framing - 75 x 1.0mm Hi-Ten TruecoreLining - Internal - 3.6mm Polyester CoatedPlywood
* Plumbing FixturesNo. Description Quantity Comments
1 Standard Laundry Unit - 45 Litre, Splashback &Wall Taps
5
2 Water Cooler - Zip Freestanding EMBCF 60 -Mains Connected
1 SS Splashback
3 Washing Machine Taps 10dp Dropper only, for 100 x 75mm Downpipe 3fw Floor Waste 5
HWS Rheem Heat Pump 325 Litre/3.6kW -MPi -mounted externally
1
Lighting Fixtures Quantity1x36W Fluro - Bare 4Single Vandalite - Wall Mounted 1Switch - Std 1
- Electrical FixturesDescription Quantity
1x10amp GPO 31x20amp GPO 102x10amp GPO 4Photo Electric Cell 1Switchboard 1
- FurnitureNo. Description Quantity Comments
4 1400 x 600 Melamine Table c/w Legs 1
Sales Mechanical EquipmentNo. Supplier Description QuantityM1 AIRFLOW Wall Mounted Exhaust Fan 2
- Floor Structure ScheduleFloor Structure Comments
Floor600mm Floor Joist CentresCovering - 1.5mm Polyflor XL Vinyl 100mm Cove
thoughoutFlooring - 17mm F11 T&G PlywoodJoists - LC7512 Galvaspan
Wall Height2445
- Electrical Equipment ScheduleNo. Description Quantity Comments
5 SPEED QUEEN 6.5kg Washing Machine 66 SPEED QUEEN 6.5kg Washing Machine c/w
Discharge Stand Pipe4
7 SPEED QUEEN 9kg Dryer 108 ROBIN HOOD Ironing Centre & Hard Wired
Steam Iron1
- Fire Services ScheduleNo. Description Quantity
9 9.0Kg Fire Extinguisher - AB(E) 1
Manufacturing Structural Members
DescriptionMember
SizeBack to
BackSkid Beams c/w RetractableLifters
150PFC 2000
Sales Door Schedule
No. Panel Height WidthHandleType
HardwareSet Closer
PanicBar
C/BJamb
TimberJamb Security Quantity Comments
D1 Standard : Hollow Core MC 2040 820 Standard Entrance No No Yes No 1
Rev Description Date By
OPTIONOPTION
OPTIONOPTION
OPTION
OPTION
DATUM RL 212.000
CUT/FILL DEPTHS
DESIGN LEVELS
EXISTING LEVELS
CHAINAGE
0.379
1.554
1.745
1.742
1.588
1.429
1.393
1.369
1.262
1.070
0.902
0.777
0.658
0.551
0.447
0.333
0.193
-0.00
2
-0.16
7
-0.43
0
-0.50
8
-0.57
6
-0.71
4
-0.90
6
-1.10
6
-1.23
6
-1.35
2
-1.47
1
-1.58
2
-1.74
9
-2.03
4
-2.40
9
-2.81
2
-2.75
6
-2.68
7
-2.63
8
-2.54
9
-2.45
9
220.8
79
222.0
56
222.2
50
222.2
50
222.0
99
221.9
43
221.8
93
221.8
69
221.7
62
221.5
70
221.3
65
221.1
58
220.9
58
220.7
69
220.5
83
220.3
88
220.1
93
219.9
98
219.7
29
219.3
61
219.1
71
218.9
85
218.7
86
218.5
94
218.3
94
218.1
65
217.9
36
217.7
04
217.4
79
217.2
51
216.9
27
216.4
74
215.9
93
215.9
93
215.9
93
215.9
93
215.9
93
215.9
93
220.4
81
220.5
00
220.5
00
220.5
00
220.5
00
220.5
02
220.5
05
220.5
08
220.5
11
220.5
14
220.5
00
220.5
00
220.5
00
220.5
00
220.4
63
220.3
81
220.3
00
220.2
18
220.1
37
220.0
55
220.0
00
220.0
00
219.8
96
219.7
91
219.6
80
219.5
61
219.5
00
219.5
00
219.5
00
219.4
02
219.2
88
219.1
74
219.0
61
219.0
00
218.9
62
218.8
83
218.8
05
218.7
49
218.6
80
218.6
31
218.5
42
218.4
52
218.3
62
218.2
72
218.1
74
00 20 40 60 80 100
120
140
160
180
200
220
240
260
280
300
320
340
360
380
400
420
440
460
480
500
520
540
560
580
600
620
640
660
680
700
720
740
760
780
800
820
840
860
880
DATUM RL 216.000
CUT/FILL DEPTHS
DESIGN LEVELS
EXISTING LEVELS
CHAINAGE
DATUM RL 216.000
CUT/FILL DEPTHS
DESIGN LEVELS
EXISTING LEVELS
CHAINAGE
SCALESECTION
1:2000H11
SK106SCALE 1:200V
SCALESECTION
1:2000H10
SK106SCALE 1:200V
FINISHEDSURFACE
EXISTINGSURFACE
EXISTINGSURFACE
EXISTINGSURFACE
FINISHEDSURFACE
FINISHEDSURFACE
SIT
EB
DY
//
SIT
EB
DY
//
-0.02
0
0.148
0.314
0.584
0.838
1.112
1.372
1.629
1.873
1.935
1.823
1.746
1.669
1.595
1.434
1.213
0.964
0.663
0.394
0.218
0.018
220.4
80
220.5
93
220.7
34
220.9
80
221.2
10
221.4
44
221.6
79
221.9
14
222.1
33
222.1
84
222.0
72
221.9
55
221.8
38
221.7
25
221.5
24
221.2
58
220.9
64
220.6
63
220.3
62
220.0
65
219.7
68
220.5
00
220.5
00
220.5
00
220.5
00
220.5
00
220.4
45
220.4
20
220.3
96
220.3
72
220.3
32
220.3
07
220.2
84
220.2
59
220.2
49
220.2
49
220.2
09
220.1
70
220.1
30
220.0
90
220.0
45
220.0
00
220.0
00
219.9
67
219.8
47
219.7
51
219.6
61
00 20 40 60 80 100
120
140
160
180
200
220
240
260
280
300
320
340
360
380
400
420
440
460
480
500
SCALESECTION
1:2000H12
SK106SCALE 1:200V
SIT
EB
DY
//
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
219.5
00
219.5
00
219.5
67
219.6
16
219.6
54
219.6
95
219.7
17
219.7
54
219.7
59
219.7
53
219.8
07
219.8
62
219.8
85
219.9
06
219.9
26
219.9
48
219.9
50
219.8
84
219.8
52
219.8
24
219.8
11
219.7
95
219.7
27
219.6
59
219.5
91
219.5
23
219.5
00
219.5
00
219.5
00
219.5
0021
9.500
219.5
00
219.5
00
219.5
67
219.6
16
219.6
54
219.6
95
219.7
17
219.7
54
219.7
59
219.7
53
219.8
07
219.8
62
219.8
85
219.9
06
219.9
26
219.9
48
219.9
50
219.8
84
219.8
52
219.8
24
219.8
11
219.7
95
219.7
27
219.6
59
219.5
91
219.5
23
219.5
00
219.5
00
219.5
00
219.5
0021
9.500
00 20 40 60 80 100
120
140
160
180
200
220
240
260
280
300
320
340
360
380
400
420
440
460
480
500
520
540
560
580
588.4
42AS 9001 Lic. 5960Standards Australia
CompanyEndorsed
QualityACN: 051 074 992Cardno (Qld) Pty Ltd
Level 11, North Tower, 515 St Paul's Terrace, Fortitude Valley 4006Locked Bag 4006, Fortitude Valley Qld 4006Phone (07) 3369 9822 Fax (07) 3369 9722Email: [email protected] Web: www.cardno.com.auThe contents of this plan are conceptual only. All areas and dimensions are approximate and
subject to relevant studies, Survey, Engineering and Council approval.
ADANI MINING PTY LTDCAMP 4 BULK EARTHWORKS SECTIONS
REF NUMBER: 7508-90-SK107(----)DATE: 23.10.2012
DRAFT FOR DISCUSSION
2020 0 806040 100m
1:2000 - A1 1:4000 - A3
6.02.0 2.00 4.0 10.0m8.0
1:200 - A1 1:400 - A3
- PROPOSED MAJOR CONTOUR- PROPOSED MINOR CONTOUR
- AREA OF CUT
- AREA OF FILL
222.0222.2
- EXISTING CONTOUR222.2
AS 9001 Lic. 5960Standards Australia
CompanyEndorsed
QualityACN: 051 074 992Cardno (Qld) Pty Ltd
Level 11, North Tower, 515 St Paul's Terrace, Fortitude Valley 4006Locked Bag 4006, Fortitude Valley Qld 4006Phone (07) 3369 9822 Fax (07) 3369 9722Email: [email protected] Web: www.cardno.com.auThe contents of this plan are conceptual only. All areas and dimensions are approximate and
subject to relevant studies, Survey, Engineering and Council approval.
ADANI MINING PTY LTDCAMP 4 BULK EARTHWORKS LAYOUT
REF NUMBER: 7508-90-SK106(----)DATE: 23.10.2012
DRAFT FOR DISCUSSION
2020 0 806040 100m
1:2000 - A1 1:4000 - A3
SRMS
SS
S
S
S
S
S
S
S
SS
S
S
S
S
SS
S
S
S
SRM SRM SRM SRM SRM
S
S
SRM
SPSSPS
SEWERTREATMENT
PLANT
AS 9001 Lic. 5960Standards Australia
CompanyEndorsed
QualityACN: 051 074 992Cardno (Qld) Pty Ltd
Level 11, North Tower, 515 St Paul's Terrace, Fortitude Valley 4006Locked Bag 4006, Fortitude Valley Qld 4006Phone (07) 3369 9822 Fax (07) 3369 9722Email: [email protected] Web: www.cardno.com.auThe contents of this plan are conceptual only. All areas and dimensions are approximate and
subject to relevant studies, Survey, Engineering and Council approval.
ADANI MINING PTY LTDCAMP 4 SEWER RETICULATION LAYOUT
REF NUMBER: 7508-90-SK304(-)DATE: 22.10.2012
DRAFT FOR DISCUSSION
10 0 10 3020 40 50m
1:1000 - A1 1:2000 - A3
W
WW
WW
WW
W
W
WW
WW
W
W
W
W
W
W W W W W W W
WW
W
W
W
W
WW
WATERTREATMENT
PLANT
W W W W W
AS 9001 Lic. 5960Standards Australia
CompanyEndorsed
QualityACN: 051 074 992Cardno (Qld) Pty Ltd
Level 11, North Tower, 515 St Paul's Terrace, Fortitude Valley 4006Locked Bag 4006, Fortitude Valley Qld 4006Phone (07) 3369 9822 Fax (07) 3369 9722Email: [email protected] Web: www.cardno.com.auThe contents of this plan are conceptual only. All areas and dimensions are approximate and
subject to relevant studies, Survey, Engineering and Council approval.
ADANI MINING PTY LTDCAMP 4 WATER RETICULATION LAYOUT
REF NUMBER: 7508-90-SK404(-)DATE: 22.10.2012
DRAFT FOR DISCUSSION
10 0 10 3020 40 50m
1:1000 - A1 1:2000 - A3