porteo 24 v - dorma | kování a dveřní technika...porteo -certified safety developed according to...
TRANSCRIPT
PORTEO24 V
D GB
Product informationAssembly instruction
Follow the instructions!
Contents
„Translation of the original documentation“CE declaration of conformity page 4
CE declaration of incorporation page 5
General informations page 6 - 11
Door basics/technical terms page 12
Functions and adjustments page 13
Approach to installation and commissioning page 14
Lintel mounting with slide channel
Door leaf mounting with slide channel
OPTIONAL -Lintel mounting with standard arm
Requirements for standard commissioning page
Standard commissioning page - 17
Extended commissioning page - 21
General safety instructions page 6 - 9Standard scope of delivery page 10Status on delivery page 11
- General information- Function- Adjustments
- Lintel mounting on the hinge side (pull-side), left-handed versionInstallation drawings
- Lintel mounting on the hinge side (pull-side), right-handed versionInstallation drawings
- Lintel mounting on the opposite hinge side (push-side), left-handed versionInstallation drawings
- Lintel mounting on the opposite hinge side (push-side), right-handed versionInstallation drawings
- Door-leaf mounting on the hinge side (pull-side), left-handed version.Installation drawings
- Door-leaf mounting on the hinge side (pull-side), right-handed versionInstallation drawings
- Door-leaf mounting on the opposite hinge side (push-side), left-handed version.Installation drawings
- Door-leaf mounting on the opposite hinge side (push-side), right-handed version.Installation drawings
- Lintel mounting on the opposite hinge side (push-side), left-handed version.Installation drawings
- Lintel mounting on the opposite hinge side (push-side), right-handed version.Installation drawings
Determine way of mounting, then mount system and commission PORTEO door assistant
15
16
18
A
B
C
D
E
F
G
H
I
J
2
Contents
Operation page 22 - 23Main switchProgram switch -adjustment of operation modes/functions
OFFPowerMotionPermanent Open
Permanent OpenPowerLessPush&Go
Adjustments page 24 - 25PowerLess
Connection diagram for connection unit
Connection diagram for electric strike (optional)
24 V DC connection, straight out of the wall page 28
Accessories (optional) page 29 - 30
Hand-held transmitter RC-T page 31 - 32
Troubleshooting instructions page 34 - 35
- Operation mode- Operation mode- Operation mode
with flip-flop-function (pushbutton -optional)- Operation mode/function- Operation mode/function- Obstacle recognition- Vandalism mode- Latching action
- Adjustment of operation mode- Adjustment of speed- Adjustment of hold-open time- Adjustment of wall blanking (optional, only with Comfort Board)- Adjustment of delayed opening for locking mechanism via DIP switchand potentiometer
- Adjustment for application of an electric strike (optional)- Adjustment of latching action
page 26
page 27
Commissioning, care, maintenance page 33
3
DORMAEG KonformitätserklärungEC Declaration of conformityCE Déclaration de conformité
4
DORMAEG EinbauerklärungEC Declaration of incorporationCE Déclaration d‘incorporation
5
This documentation contains important information regarding the mounting and the safeoperation of the door system.Please read these instructions carefully before using the
An incorrectly performed installation might cause serious injuries.Using control elements, making adjustments or performing procedures that are not described inthis documentation might cause electric shocks, danger caused by electric voltage/current and/ordanger due to mechanical incidents.Please keep these documents for further reference and hand them over to the person in charge incase the system is transferred to another party.
This symbol underlines important information that may facilitate your work.This symbol warns you of possible system damage and explains how to avoidthis damage.This symbol indicates dangers that might cause personal or material damageor even kill people.
As electromechanical operator, the is only designed to open and close interior swingdoors with an admissible door-leaf weight up to 125 kg.The is neither suitable for application in escape routes, nor at fire doors (fire and smokedoors) nor at exterior doors.The maximum cable length for external components must not exceed 30 m.
The may only be used according to its specified intended application. EigenmächtigeThe will not accept any liability for damage resulting from unauthorisedmodifications of theFurthermore components/accessories that have not been approved by DORMA are exempted fromliability.
Do not allow children to play with the or its adjustment and control devices.Keep remote controls out of reach of children.Never stick metal objects into the openings of the otherwise you might sustain anelectric shock.If the is mounted onto a metal door leaf, you have to earth (ground) the door leafproperly.Glass door leaves have to be made of safety glass.
Weight ofPower supplyFuse (by others) 6
Operating noise < 70 dB(A)
PORTEO.
It is important for your personal safety to abide by all enclosed instructions.
Explanation of symbolsNOTEREMARK
WARNING
Intended applicationPORTEO
Limitation of liability
DORMA GmnH + Co. KG
Safety instructions
Work on electrical equipment may only be performed by properly qualified staff(electricians).
Important technical data
The system is connected to the door leaf via slide channel or standard arm.
PORTEO
PORTEO
PORTEO
PORTEO
PORTEO;
PORTEO
PORTEO
�
�
�
�
�
�
�
�
3,2 kgV DC (+_ 15%)A
24
1. For your safety
6
NebenschließkanteGegenschließkante
Hauptschließkante
Standards, laws, codes and regulations
DIN 18650 (German Industrial Standard)
PRODUCT
Dangers at closing edges
Automatic doors might cause hazards bycrushing, shearing, hitting and drawing-inat the different closing edges.
Dangers caused by slide channel and arm
The slide channel and the arm might cause hazards by crushing and shearing.
Residual risk
Low-energy productPORTEO
Risk assessment on the part of the installer
PRODUCT
�
�
�
The latest versions of the common and country-specific standards, laws, codes and regulationshave to be observed.
During the planning of the door system, the manufacturer (the person installing the system) andthe commissioner/facility operator have to perform an individual risk assessment (together).Please refer to our homepage and consider the provided “risk assessment form”under for further assistance when performing your individual risk assessment.
Depending on the structural conditions, the prevailing door version and the available safetyequipment, residual risks such as crushing and hitting (with a limited force) cannot be excluded.All people using a door are generally aware of the danger spot at the secondary closing edge ofevery swing door (also at manually operated doors).This danger spot cannot be influenced by the manufacturer of the operator and a protection ofthis closing edge often cannot be realised due to its construction and technical function.A suitable clamping protection (like a rubber or textile cover) is available in the specialised tradeand not part of the scope of delivery.
The meets the requirements of a low-energy application in accordance with the GermanDIN 18650 (industrial standard).
Reduced dynamic force at door leaf and reduced contact force via low driving speed.Reduced static force at door leaf and reduced contact force via force limitation.
The door system does not compulsorily require additional safety equipment.The application of safety sensors at the main closing edge and the secondary closing edges asadditional safety equipment is optional and lies in the discretion of the person performing theinstallation of the door system - under consideration of the result of the individual riskassessment.
Due to special spatial conditions and the expected user groups of the door, the application ofsafety sensors could be reasonable also for a low-energy operator.Thus the manufacturer, i.e. the installer of the system, has to perform an individual riskassessment during the planning of the door system in order to decide whether additional safetyequipment is required or not.Please refer to our homepage and consider the provided “risk assessment form”under for further assistance when performing your individual risk assessment.
www.dorma.com
www.dorma.com
7
Special requirements regarding the protection of people in need of protection
Recycling and disposalPORTEO
PORTEO
Safety during mounting
PORTEO
PORTEO
PORTEO
PORTEO
PORTEO
Safety during commissioning
Inspection and system approval
PORTEO
We would recommend taking out a maintenance agreement with DORMA.
In case the risk assessment reveals that there is a health risk or risk of injury caused by the doorhitting a person using the door with an unacceptable force, an additional protection with the aidof appropriate safety equipment (connection of a safety sensor) is required. This is especiallynecessary when people in need of protection (children, elderly people or disabled people) use thedoor.
Both the and its packing mainly consist of recyclable raw material.The and the respective accessories must not be disposed of as domesticwaste.Please ensure that the old appliance and the respective accessories (if available) areproperly disposed of.
Please abide by the prevailing national statutory provisions.
The working area has to be secured against unauthorised access from other people. Falling itemsor tools might cause injuries.
The has to be secured against water and other liquids.In any case, the way of mounting and the mounting equipment, like for example screws andwall plugs, have to be adequate with regard to the structural conditions (steel structure, wood,concrete etc.).Before installing the the door leaf has to be checked with respect to propermechanical condition and smooth running.The mounting of the described herein is only an example. Structural or localconditions, available tools or other conditions might suggest a different approach.Following the successful installation of the system, the settings and the proper function of the
and the safety equipment have to be checked.Only specially qualified staff may open the power supply housing.
Disconnect the from power supply (de-energise the system) before removing the coverof the power supply housing. Remove mains plug or switch off fuse (with permanent powersupply).Always pull at the plug and never at the cable when unplugging the power supply.
The protective earth conductor has to be connected.The safety sensors are to be connected (see commissioning instructions)..Separately supplied components such as the program switch, the EMERGENCY OFFpushbutton and activators (radar motion detectors, NIGHT-/BANK key switches) have to bemounted and connected.Ensure that the door leaves run smoothlyThe operator and the door leaf must be properly linked.
Before the first commissioning and depending on requirements, however, at least once a year, thehas to be inspected by a properly qualified technician and serviced if required.
A person trained by DORMA has to perform the inspection and approve the system with the aid ofthe inspection book.The respective results have to be documented in accordance with DIN 18650-2 and the facilityoperator has to keep these documents for at least one year.
�
�
�
�
�
�
�
�
�
�
�
�
�
�
8
PORTEO -certified safety
Developed according to the latest safety standards:
The and the certificate can be obtained from the manufacturer ondemand.
"low energy" according to DIN 18650TÜV approvalmark
GGT-seal of approval
TÜV certificate
Briefing:
Maintenance
PORTEODORMA.
Care
PORTEO
PORTEOPORTEO
Wear
Following the adjustment, commissioning and functional testing of the door system, the operatinginstructions have to be handed over to the facility operator and a briefing has to be made.
The system has to be de-energised (disconnected from power supply) before performing any kindof maintenance work. Remove the power plug or switch off the fuse (with permanent powersupply).Please consider the leaflet regarding the application of hold-open devices for further informationand instructions regarding the application of the at fire and smoke doors.We would recommend taking out a maintenance agreement with
The system has to be de-energised (disconnected from power supply) before cleaning the system.Remove the power plug or switch off the fuse (with permanent power supply).You may clean the with a damp cloth and standard commercial detergents.You should not use scouring agents for cleaning purposes as they might damage the surfacefinish.Ensure that no water or other liquids drop on or into theNever stick metal objects into the openings of the otherwise you might sustain anelectric shock.
The slide piece has to be inspected at regular intervals (every year) and replaced if required.Only use original spare parts.
9
Standard scope of delivery
171715
1
2
3
4
5
6
7
8
9
10
11
12
13
14
b)a)
Status on delivery:A smoothed DC power supply at 24 V DC, ±15 %, 4 Awith an electronic circuit breaker, I = 6 A, must be available.The device has to be provided with safety extra low voltage.All electrical connections have to be realised by others.
N
A
Use the enclosedtools to adjustthe potentiometers.
Mounting plateDrive unitCoverCoverAxle cover, topAxle cover bottomCoverDORMA LogoSlide channel armFixing screw
Fixing screwSlide channelCover of slide channelFixing materiala) Drive unit/Mounting plateb) Slide channel
Documentation
(without illustration)- Installation drawings- Extended documentation- Drilling template- 60° angle template- 420 mm template
Storage place forpotentiometer tool
1x 2x2x
1x 2x2x 2x
b)
a)
7901 507901 501
2
3
5
46
7
13
8
12
A
91110
10
Status on delivery and assistance when it comes to selecting appropriate accessories
Required accessories for the respective way of mounting
Cable loop -optionArt.-No. 60041401
Obligatory accessories
Lintel depths from30 to 90 mm
Projecting arm
Lintel depths from90 to 200 mm
none
179050
Standard
Lintel mounting
Door-leaf mounting:
Option Lintel mounting withprojecting arm.
:- (pull-side),
left-handed versionon the hinge side
- on the hinge side (pull-side),right-handed version
- on opposite hinge side (push-side),left-handed version
- on opposite hinge side (push-side),right-handed version
- on the hinge side (pull-side),left-handed version
- on the hinge side (pull-side),right-handed version
- on the opposite hinge side (push-side),left-handed version
- on the opposite hinge side (push-side),right-handed version
When it comes to door-leafmounting, the power cord has tobe protected from crushing.
- on the opposite hinge side (push-side),left-handed version
- on the opposite hinge side (push-side),right-handed version
On application of the projectingarm, the slide channel is nolonger required.
Compulsory for lintel depthsbeyond 30 mm:
Authorised DORMA specialist dealers offer competent advice and the required accessories for thePORTEO door assistant.
Required tools for the installation of the PORTEO door assistant
Drill bit, depending on surface
- Allen key, 5 mm (Scope of delivery)- Potentiometer-tool (Scope of delivery)- Power drill-
Please ask for our templateWN-No.: 057193-45532
11
"Door basics" technical terms
- Lintel mounting on opposite hinge side (push side)- Left-handed design (right-handed version is laterally reversed)- with slide channel (standard)
Example 1
PORTEO door assistant
A rack & pinion arm has to be applied on the hinge sidewhen it comes to lintel depths of more than 30 mm.
- Lintel mounting on opposite hinge side (push side)- Left-handed design (right-handed version is laterally reversed)- with rack & pinion arm (option)
Example 3
PORTEO door assistant
A rack & pinion arm (option) has to be applied on the hinge sidewhen it comes to lintel depths of more than 30 mm.
- Door leaf mounting on hinge side (pull side)- Left-handed design (right-handed version is laterally reversed)- with slide channel (standard)
Example 2
PORTEO door assistant
Rebate dimensions
Lintel depth
Lintel mounting
Door hinge
Hinge side
Main closing edge
Opposite hinge side
12
General informationPORTEO door assistant
Settings/Adjustments
The has been pre-adjusted for various kinds of applications (basicsettings).
The settings: swing direction, door weight, door width, way of mounting, andare important for the smooth and proper operation of the door system.
Some of these settings are part of the basic settings, others have to be determined while somesettings are determined automatically during the learning cycle.The determination of the settings is a simple and plain procedure that is described on thepages 16 to 21.
The opening or closing cycle is triggered either by active or automatic activators.The activator sends a signal to the control unit.The control unit in turn sends the pulse to the motor.The motor starts and converts the pulse into a movement.The arm transfers the movement of the motor onto the door.The door performs either an opening or a closing cycle.There are either active or automatic activators.
Active activators are for example pushbuttons or door handles while automatic activators areradar motion detectors or sensors.
- swing direction -left or right- way of mounting -lintel mounting or door leaf mounting- mounting side -hinge side/pull side or opposite hinge side/push side- lintel depth (see page 12)- kind of accessory -slide channel (standard) or projecting arm- door width- door weight- position of the door when closed (”closed” position)- position of the door when it is completely open (”open” position, freely adjustable)- and latching action.
Each setting is learnt automatically during commissioning.Follow the instructions indicated in the commissioning instructions.
- see page 16 and 17.- see page 18 to 21.
"closed" position"open" position
Function
The control unit of the PORTEO door assistant requires the following parameter settings forcontrol-internal operations:
Standard commissioningExtended commissioning
Function and adjustments
13
Approach to installation and commissioning
A B C D
24 V DC
1.
This connection version may only be performedby a properly qualified company.
24V DC connection straight through the wallpage 28.
2. Perform the mounting with the aid of theenclosed installation drawings.Select the appropriate installation drawing foryour way of mounting.
Lintel mounting withslide channel (standard).
Door leaf mounting with slide channel
Lintel depth mounting. with projecting arm(option).
3. Following the installation, commission thePORTEO door assistant.
standard commissioning
extended commissioning
Either with , seeoperating instructions on page 16 and 17orwith , see operatinginstructions on page 16 to 21.
Betriebsanleitung
E F G H
I J
14
Requirements for standard commissioning
Basic settingsbasic settings
- lintel mounting
- with slide channel
- on the hinge side (pull side)
- door weight of up to 60 kg
- door width of up to 1,000 mm
standard commissioning
Deviations from basic values of original settings.
Door leaf width and admissible maximum weights
"extended commissioning"
The offer base values for these settings:
Most interior doors have a door width of less than 1,000 mm and a door weight of less than 60 kg.
As far as the structural conditions as well as the basic values of the lintel-mounted operator withslide channel on the hinge side (pull side) correspond to the above-mentioned basic values, thedoor closer can be commissioned with the aid of the .
page 16 to page 19.
In case the basic values are not identical with the basic settings, the deviant settings have to bedetermined and adjusted.The deviant settings are determined and readjusted during the ,
In case the basic values are not identical with the basic values of the , thedeviant settings have to be determined and adjusted during the .
original settingsextended commissioning
max. 1,000 mm
max.60KG
door leaf width in mm600700800900
1,0001,100
max. door weights in kg125110100
908080
15
Standard commissioning
Requirements-- The system has been connected to the DC power supply.----
The stored settings can be "overwritten" by a new commissioning procedure.The “approach” describes the commissioning of the standard system.Accessories like for example electric strikes or sensors are adjusted following the successfulcommissioning of the system.
The has been installed.
The door can easily be moved by hand.Perform the following steps of the one after the other.The (visual) acknowledgement is made via the light indicator (LED).You can stop and restart this procedure at any time by simply switching off the system.
PORTEO door assistant
standard commissioning
Standard commisioning
Set main switch to .Set program switch to position(central position).
"0FF""0"
1
0I
II0FF
ON
0N
0FF
16
Standard commissioning
- Open door by approximately 5°.Determination of swing direction:
- Move door to desired position.The LED (green) blinks.
- Press service key once.The LED emits a permanent light for 3 sec.,then it blinks
The door determines this position as itsposition.The door travels to its position.
The LED (green) emits permanent light.
Determination of "open" position:"open”
"open"
"closed"
Following the learning cycle, the PORTEO door assistant is ready for operation.
adjustments page 24 and 25Now you can perform further adjustments like speed, hold-open time or adjustments regardingthe optional accessories like for example the electric strike, see .
2
- Press service key andswitch on power switch.Press and hold service key for 8 sec. untilthe door starts moving, then release theservice key.The LED (green) blinks.
The door determines the swing direction andtravels to its position.
Determination of swing direction:Simultaneously, until the door starts moving,
"closed"
5°
3
4
5
max. 110°
LED
0FF
0N
LED
0FF
0N Service pushbutton
17
Extended commissioning
When it comes to deviations from the basic values of the original settings (see page 15), an extendedcommissioning is required.
For example:
)
Approach in case of extended commissioning and learning cycle
RequirementsPORTEO door assistant
PORTEO door assistant
- projecting arm instead of slide channel- a different door width (more than 1,000 mm- a different door weight more than 60 kg)
You can stop and restart this procedure at any time by simply switching off the system.
- The has been installed.- The door can easily be moved by hand.
The stored settings can be "overwritten" by a new commissioning procedure.The "approach" describes the commissioning of the without anyaccessory.Accessories like for example electric strikes or sensors are adjusted following the successfulcommissioning of the system.
Extended commissioning
Preparation 1
Close the door.
Preparation 2
ON1 2 3 4
A B C D
OFF
1 2 3 4
A B C D
ONOFF
Set DIP switch to position- =- =(Set the switch to the correct position withthe aid of a small screwdriver.)
, thehas a different function, see page 25
.
Always set DIP switches , and toposition.
Select an arm version:"A"
"ON" projecting arm"OFF" slide channel
Following commissioning DIP switch "A"
" "
"B" "C" "D""OFF"
adjustment of latching action
18
~5°
0FF
ON0I
II
0FF
0N
LED
Extended commissioning
- Open door by approximately 5°.Determination of swing direction:
The LED (green) blinks.
1 Close the door.Set main switch to position.Set program switch to position(central position).
The LED (green) blinks.
"0N""OFF"
2 Service pushbutton
19
Extended commissioning
- Open the door by approximately 420 mm(420 mm angle template is enclosed).The LED (green) blinks.
- Press service key once.The LED (green) emits a permanent light for3 sec. then it blinks.
.
Teaching-in the door width:
During this procedure the control unitdetermines and stores the door width
3
4
5
- Press service key, untilthe door starts moving (approx. 3 sec.).The LED (green) emits a permanent light for3 sec., then it blinks
The door travels to position.
Determination of swing direction:
During this procedure the control unitdetermines and stores the swing direction ofthe door.
"closed"
- Open door by approximately 60°.(60° angle template is enclosed).The LED (green) blinks.
- Press service key once.The LED (green) emits a permanent light for3 sec. then it blinks.
Teaching-in the way of mounting and armversion:
During this procedure the control unitdetermines and stores the way of mountingand the arm version.
Service pushbutton
LED (green)
Service pushbutton
420mm
60°
LED (green)
LED (green)
Service pushbutton
20
Extended commissioning
- Move door to desired .- Press service key once.
The LED (green) emits a permanent light for3 sec., then it blinks.
The control unit stores this position as.
After 10 seconds, the door closes at low speed.An automatic learning cycle starts.
Then the door remains in .
The LED (green) emits a permanent lightsignal.
Determination of "open" position:"open" position
"open" position
The door performs some movements thatmust not be interrupted.
"closed" position
6
10 sec.
Following the commissioning and learning cycle, the PORTEO door assistant is ready foroperation. The operating instructions, to follow.
adjustments page 24 and 25For adjustments like speed, hold-open time or adjustments regarding the optional accessorieslike for example the electric strike, see .
7
max. 110°
LED
Service pushbutton
21
Operation
0
0
Operating type/functionsMain switch
OFF
0N
Program switch
Main switch in "ON" position..
PORTEO door assistant
I = PowerMotion0 = OFFII = Permanent Open
Program switch in "O" (OFF) position"0"
PORTEO door assistant
Program switch in "I" position = "PowerMotion""PowerMotion"
Please note!
Before activating the program switch, you have to ensure that the door is neither closed norlocked.Otherwise the door cannot leave "closed” position.
Program switch in position "II" = "PermanentOpen"Set program switch in position "PermanentOpen".
"PermanentOpen"
OPTION - "PermanentOpen" with flip-flop function, in program switchposition "PowerMotion" with pushbutton or hand-held remote control asactivator.
When in position:- The electric functions of the are switched off.
The does not have a functionThe door can be accessed manuallyEither via door handle or key
When in position, the opening and closing cycles arecontrolled by activators.
When an opening pulse is triggered the door opens automatically andcloses automatically on expiry of the preset hold-open time
s c to sec
In case an opening pulse is triggered during the hold-opentime (while the door is in “open” position), the hold-open time is reset,that means it starts from 0 sec.
When in position- The door travels to "open" position and remains in this position, untilanother operating type is adjusted with the aid of the program switch.
- ..
.
-
(5 e . 30 .).
Press pushbutton twice in short succession or press the programmedpushbutton on the hand-held transmitter once:- the door travels to "open" position and remains in this position.The door closes as soon as the pushbutton is pressed again twice inshort succession or the programmed pushbutton on the hand-heldtransmitter is activated again for one time.
0FF
0N
22
Operation
Operating type/function "PowerLess""I" (PowerMotion) "PowerLess"
manually and without effort
"PowerLess" potentiometer 1"Adjustable settings" page 24 and 25
Operating type/function "Push&Go".Requirement:
"I" (PowerMotion). Potentiometer 1"PowerLess" "Push&Go"
"PowerMotion""Push&Go"
Obstacle recognitionDuring the opening travel
During the closing travel
"off"
Vandalism modePORTEO door assistant
Latching action
Blocking recognition
Program switch in position . During operation, thedoor can be opened .Open the door with the door handle. The door closes automatically on expiry ofthe hold-open time.The function is adjusted via .See .
Program switch in position must not be setto position. The function is permanently activatedduring operation.In mode, the opening pulse is triggered by a manual movement ofthe door by approx. 3°:
- The door travels to "open" position and closes automatically on expiry of the hold-open time.When a further opening pulse is triggered during the closing cycle (the door is opened against itsswing direction), the door travels back to the adjusted “open” position and closes automatically onexpiry of the adjusted hold-open time.
If the door meets an obstacle during the opening travel, the opening travel is stopped immediately.After approx. 3 sec. the door restarts an opening travel. If the door runs against an obstacle before ithas reached its „open“ position (3x), it will reverse and move to its „closed“ position. This procedureis repeated whenever an opening pulse is triggered until the obstruction has been removed.
If the door meets an obstacle during the closing travel, the closing travel is stopped immediately.The door stops at the obstacle. After some seconds the door drives some degrees in the direction
, in order to relieve the obstacle. After a waiting period the door tries to close again. Thisprocedure is repeated three times, then the door stops at the obstacle and remains in this position.As soon as the door is pushed manually in opening or closing direction by approx. 3°, the door willmove automatically in the desired direction.
The has a vandalism mode.In case the door is pressed against its original driving direction during an opening or closing cycle,the gear is disabled (the door can be operated manually).Following approx. 5 seconds the door automatically returns to the adjusted function program.
The latching action accelerates the closing speed when the door reaches the last few degrees beforeit closes in order to overcome air resistance, the closing resistance of the latch and thefriction/resistance caused by door sealings (if available). The latching action is deactivated ondelivery. For adjustments please refer to page 25.
If an opening signal is triggered while the door is locked, the door will try to perform an openingcycle (1x) and then switch off. In case a further opening signal is triggered, the system will ignore itfor 5 seconds and then repeat the above-mentioned procedure. As soon as the door is pushedmanually in opening direction, it will continue its cycle in the desired direction and the adjustedoperation mode.
23
Adjustments
Speed
+PowerLessPosition
2 1Speed
Hol
d-open time
PowerLessPosition
Wall
blanking
++
+
+ +
Del
ayed opening
3 4
Serv
ic
e pushbutton
++ +
1
2
3
4
= PowerLess
= Speed
= Hold-open time
= Wall blanking
= Delayed opening forlocking mechanism
= Service pushbutton
= Light emitting diode(LED, green)
= DIP switch
Speed
PowerLessPosition
++
Adjustable settings
potentiometers 1 4- Function "PowerLess" - Speed- Delayed opening for locking mechanism - Wall blanking- Hold-open time
Adjust the mode of operation "PowerLess"
"ON""I" PowerMotion
potentiometer 1 "PowerLess"
"PowerLess"
Adjust the speed
"ON"
potentiometer 1
"PowerLess" lowest possible speed"PowerLess"
The following settings can be adjusted with the aid of the (controllers) to :
Set power switch in position .Set program switch in position ( ).Turn (speed) to the left as far as possible to position
When in mode, the door can be opened manually and almosteffortlessly. The door closes automatically on expiry of the adjusted hold-open time.
Set power switch in position .
Adjust the desired opening and closing time (speed) via .The original setting for the driving path from 0° to 90° amounts to 10 seconds.The original setting for the driving path from 90° to 0° amounts to 10 seconds.The speed is adjustable from 5 sec. to 10 sec. and is for the driving path for anopening angle from 0° to 90°.- = lowest possible speed (driving time = 10 sec.)+ = highest possible speed (driving time = 5 sec.)
Do not confuse the position with the(direct in front of ).
.
10 sec.
1 2 3 4OFFON
A B C D
ON1 2 3 4
A B C D
OFF
Use the enclosed tool (potentiometer tool) to adjust the potentiometers.
24
Adjustments
Hol
d-open tim
e
++
+
W
allblanking
+
+
Del
ayed opening+
Adjust hold-open time
"ON"
potentiometer 2
+
Adjust wall blanking (only with optional sensor technology)
"ON"
potentiometer 3
+
Adjustment for application of an electric strike (optional)
Set program switch in position .
Adjust the desired hold-open time via .The hold-open time is adjustable for a period from approx. 5 sec. to 30 sec.
= 5 sec. hold-open time= 30 sec. hold-open time
Set power switch in position .
Adjust the wall blanking viaThe wall blanking is adjustable from approx. 80° to 110°.
= 80° opening angle= 110° opening angle
Adjustment of latching action.Following the successful commissioning of the system, DIP switch A is assigned with anotherfunction. Use DIP switch A to adjust the latching action following the commissioning of the system.This does not have an influence on the previous adjustments (arm versions).
Adjustment of hold-open time during "PowerLess" operation mode/function.potentiometer 1 "PowerLess"
potentiometer 2
Adjustment of delayed opening for locking mechanism
potentiometer 4
Turn to position.Adjust the desired hold-open time via .The hold-open time is adjustable for a period from approx. 0.5 sec. to 30 sec.
= 0,5 sec. hold-open time+ = 30 sec. hold-open time
Adjust the delayed opening for the locking mechanism via .The delayed opening for the locking mechanism is adjustable between approx. 0.2and 3 seconds.- = delayed opening for locking mechanism of 0.2 sec.+ = delayed opening for locking mechanism of 3 sec.
1. Adjust DIP switch to A.- The latching action is now deactivated.- The door closes softly and remains in “closed“ position.- Suitable for light doors.
2. Adjust DIP switch to A.- The latching action is now activated.- The door is accelerated atthe last few degrees before the door reaches ist“closed” position.
- The door is no longer pushed shut while closed.- Suitable for doors that are subject to high resistance forces.
.
ON
A
OFF
B C D
1 2 3 4
25
Connection diagram for connection unit
+ 24 V DC
0 V DC
Not assigned
+ 24 V DC
0 V DC
+ 24 V DC
0 V DC
Activator (e.g. hand-held transmitter,radar sensor)
Activator (e.g. hand-held transmitter,radar sensor)
Electromechanical locking devicepotential-free changeover contact
:
Power supply forexternal accessories
e.g. locking device24 V DC max. 300 mA
1U
3
42
3
1U
3
42
3
1U
64
63
62
CN
3
Sta
rtS
tart
26
Connection diagram: electric strike
1U
64
63
62
CN
3
24 V DC power supplyLocking device (fail-secure type) with integrated
FAIL-SAFE DESIGN 1U
64
63
62
CN
3
1U
64
63
62
CN
3
FAIL-SAFE DESIGN
FAIL-SECURE DESIGN
Power supply
1U
64
63
62
CN
3
Power supply
FAIL-SECURE DESIGN
Locking device (fail-secure type) with external power supply
Locking device (fail-secure type) with integrated 24 V DC power supply
Locking device (fail-secure type) with external power supply 24 V DC
3 4Adjust desired delayed openingfor locking mechanism0.2 sec. to 3 sec.
27
10
20
22
20
54
112
3
1
2
Before installationThis connection version may only be performedby a properly qualified company.Disconnect system from power supply(remove fuse).
The drawing shows a left-handed installation.The right-handed installation is laterallyreversed.
24 V DC connectionThe cord must come out of the wall in theposition indicated on the picture (installationof cord by others).
Install PORTEO.
Put the cable into the intended "slot" duringthe installation.
Fit connection bayonets.
Protect the cables with the aid of siliconetubes.
Connect the cable at the terminal and fix withscrew, that attach counterpiece.
Direct power supply, straight out of the wall
28
Accessories
Angle bracketFor installation of slide channel on opposite hinge side (push side) whenit comes to door frames with deep lintel. Safety sensors (optional).
Mounting plates, 30 mm and 40 mmFor mounting of slide channel at door frames that are not suitable for direct mounting.
5
40
30
10
77
95 95
20
10
23
33
530
Glass door clamping railIn order to fix the slide channel to all-glass doors no processing of the glass is required.Only for lintel mounting on hinge side.
53077
172 172
25
4
15
32
25
5,5
516
17
,5
8 - 10min
.5
24
27SW 3
530516
29
Accessories
Electric strike - Type BasicStandard fail-secure electric strike of symmetrical designwith adjustable latch, non-handed, suitable for over-rebated and flush-closing doors (any position), includingfree-wheeling diode supplied loose for the DC versions.See enclosed installation instructions for installation andelectrical connections.
Safety sensors (optional)
DORMA IRS-3
PORTEO door assistantDORMA Comfort BoardPlease contact your DORMA specialist dealer for further information.
When the risk assessment reveals that the application of contactless safety devices isrequired, the swing range of the door has to be protected by moving active infraredsensors.In this case the has to be equipped with another connection unit, the
.
+ 24 V DC
0 V DC
+ 24 V DC
0 V DC
1U
3
42
3
1U
3
42
Sta
rtS
tart
NO
Manual release switch DORMA system 55 (option)
3
L
12
30
DORMA atent radio remote controlDORMA atent
An infinite number of hand-held transmittersmay be allocated to the PORTEO. Every hand-held transmitter has to be programmedindividually
BRC-R
PORTEO.PORTEO
PORTEO
PORTEO
ProgrammingActivator 1 - PowerMotion(Automatitic opening/closing of the door)
DORMA
BRC-R
DORMA
ctivator 2 - Permanent Open
DORMAatent
BRC-R
BRC-R
DORMA atent
Functional characteristicsActivator 1 - PowerMotion
Activator 2 - Permanent Open
.
is designed to open and closedoors automatically via radio control.
.The receiver board (to be orderedseparately) is inserted in the provided slot at the
It is possible to connect the crimpconnector of the direct to the receiverboard.In case the has not yet been equippedwith a crimp connector, the cables of the
may be connected with the aid of thecrimp connector accompanying the receiverboard. Please connect the violet cable at the sidewith the arrow marking.
1. Activate the “teach” key on the atentwith the aid of a suitable object.
2. Press and hold the “teach” key on thereceiver board for 4 seconds. The LED blinksred.
3. Push the respective keyon the atent toactivate the PowerMotion function
4. The LED goes out and the programming iscompleted.
A
1. Activate the “teach” key on thewith the aid of a suitable object.
2. Shortly push the “teach” key on thereceiver board. The LED blinks red (fast).
3. Then press the “teach” key on thereceiver board again and hold the key forapprox. 4 seconds. The red LED now blinksmore slowly.
4. Push the respective key on theto activate the Permanent Open
function.5. The LED goes out and the programming is
completed.
(Automatic opening/closing of the door)Push the correspondingly programmed key
(to open the door). on the hand-heldtransmitter:
The door moves to its “open” position andautomatically closes on expiry of the adjustedhold-open time.
Push the programmed key (to activate thePermanent Open function).on the hand-held transmitter:The door opens and remains in its “open”position.Push the programmed key (to activate thePermanent Closed function)on the hand-held transmitter:The door opens and remains in its “closed“position
Hand-held transmitter DORMA Atent
Violet
Orange
BlueGreenYellow
Receiver BRC-R
“teach” key
PORTEO without crimp connector
31
Resetting the programmingIn order to delete the programming, both the DORMA atent and the BRC-R receiver board haveto be reset.
DORMA atentDORMA Atent
DORMA atent
DORMA atent
BRC-RBRC-RBRC-R
1. Press and hold the “teach” key on the for more than 5 seconds. The redLED blinks slowly. (If you want to stop the system reset, simply press the "teach” key again for ashort time. The red LED no longer blinks slowly but stops blinking.).2. Press and hold the “teach” key of the once more for 5 seconds. The red LEDnow blinks faster as long as you press and hold the key.3. As soon as you release the key, the system reset is completed and the LED shows apermanent red light in order to confirm the system reset. The has now been reset.
receiver board1. Press and hold the “teach” key on the receiver board for more than 4 seconds.2. Press and hold the “teach” key on the receiver board once more for more than 4
seconds.3. The system LED blinks fast in order to indicate that the receiver board has been reset
successfully.
32
ICommissioning, care and maintenance (requirements according to DIN 18650-2, 5.1-5.4)
PORTEO door assistant
PORTEO door assistant
Checklist (start-up test, maintenance, regular inspections) for PORTEO door assistant according toDIN 18650-2, paragraph 5.1-5.4
PORTEO door assistant
only for PORTEO as Full Energy version
PORTEO door assistant
DIN 18650 also prescribes safety standards for the commissioning and maintenance of thecomplete automatic door system. As long as the facility operator intends to use the
according to this standard, the following requirements prevail
Inspection and acceptance test according to the below-mentioned checklist before the firstcommissioning by a person trained by us.
maintenance and inspection, at least 1x a year, under consideration of ourspecifications for the by trained staff.
Documentation of the results in accordance with DIN 18650-2 paragraph 5.1-5.4Safekeeping of the properly filled-out checklist according to our specifications for at least1 year by the facility operator.
Proper installation according to the instructions of the manufacturer.Tight fit of the to the lintel/frame respectively, or the door leaf
Check door leaf for smooth running and adjust, if required
Proper functioning of the door (check the opening and closing cycle respectively)
Function of installed activators like radar motion detectors, pushbuttons or remote controls
Function of the contactless safety equipment (safety sensors), if installed
Installation of effective safety equipment to avoid or protect danger spots between certainparts of the door and between the door and its structural environment, like for example safetyclearances or the protection of the secondary closing edges
Fix inspection plate
Document the inspection and maintenance work
The has to be switched off and secured against unauthorised or unintendedswitching-on before performing maintenance work (cleaning or maintenance).
Regular
.
.( .)
.
.
.
( ).
,.
.
.
Commissioning, care, maintenance
33
Troubleshooting instructions
The LED light indicatoris off.The door does notrespond.
The LED light indicatoris on.The door does notrespond.
The LED light indicatorblinks.The door does notrespond.
The door stops duringist cycle.
No DC voltage.
Loose cable connections.
Defective cable.
Fuse switched off.
Defective door assistant.
The system is adjusted tomode.
The door has been opened via theflip-flop-function and is thusadjusted to .
Defective door assistant.
The learning cycle has not beencompleted successfully.
External malfunction.
Defective door assistant.
The door does not run smoothly.
There is an obstruction within thedoor's driving path.
“PowerLess”
“Permanent Open”
Switch on mains switch.
Fix the loose the cable connections.
Replace cable.
Switch on fuse.
Replace door assistant.
Deactivate mode viapotentiometer 1. See operatinginstructions on page 24.
Close door via flip-flop-function.Activate the pushbutton twice inshort succession.
Replace door assistant.
Restart learning cycle.
1. Set program switch toposition.
2. Adjust program switch to thedesired operation mode.
3. Set mains switch toposition.
4. Wait for 5 seconds, then adjustmains switch to .
Replace door assistant.
Check the door and the driving pathand remove the reason for theunsmooth running.Check the slide channel for dirt orwear and clean or replace it ifrequired.
Remove obstruction.
“PowerLess”
System reset:“0”
“OFF“
“ON“
Malfunction Possible cause Remedy
34
Malfunction Possible cause Remedy
Troubleshooting instructions
www.dorma.com/porteo
The door moves beyondthe adjusted openingangle.
The door does not reachthe adjusted openingangle.
The door opensautomatically followinga closing cycle.
General malfunctions.
The opening angle is adjustedincorrectly.
The screws of the slide channel havebecome loose.
Obstruction in the driving path.
The opening angle is adjustedincorrectly.
The screws of the slide channel havebecome loose.
The screws of the slide channel havebecome loose.
Repeat learning cycle.
Tighten screws thoroughly.
Remove obstruction.
Repeat learning cycle.
Tighten screws thoroughly.
Tighten screws thoroughly.
1. Set program switch toposition.
2. Adjust program switch to thedesired operation mode.
3. Set mains switch toposition.
4. Wait for 5 seconds, then adjustmains switch to .
System reset:“0”
“OFF“
“ON“
35
Door Control
Automatic
Glass Fittings andAccessoires
Movable Walls
www.dorma-porteo.com
DORMA worldwide
Security/Time andAccess (STA)
WN
05
78
14
45
53
2, 0
1/1
0, P
orte
o 2
4V,
GB
,S
ubje
ct t
o ch
ange
wit
hout
not
ice
DORMA worldwide
Central Europa
Australasia
China/Honh Kong
Emerging Markets
DORMA GmbH + Co. KGDORMA Platz 1D-58256 EnnepetalPhone +49 2333 793-0Fax +49 2333 793-495
DORMA Door Controls Pty. Ltd.46-52, Abbott RoadHallam/Victoria 3803Australia
+61 3979 63555Fax +61 3979 63955
DORMA Door Controls(Suzhou) Co. Ltd.No. 9, Hong Feng RoadSuzhou Singhapore Industrial ParkSuzhou, 215021P.R. of China
+86 512 67612481Fax +86 512 67614582
DORMA Door Controls Pte. Ltd.Room 701, Technology Plaza651 King’s RoadNorth PointHong Kong
+852 25034632Fax +852 28875370
DORMA GmbH + Co. KGDORMA Platz 1
Phone
Phone
Phone
D-58256 EnnepetalPhone +49 2333 793-0Fax +49 2333 793-495
DORMA Door Controls (Pty.) Ltd.Kings Court4A Mineral CrescentZA-2000 Crown/GautengSouth AfricaPhone +27 11 8300280Fax +27 11 8300291
DORMA Far East Pte. Ltd.No. 31 Gul LaneSingapore 629425Phone +65 6268 7633Fax +65 6265 7995
DORMA France S.A.S.Zone EuroparcImmeuble Mega 4242, rue Eugène DupuisF-94046 Créteil CedexPhone +33 1 41942400Fax +33 1 41942401
DORMA Accueil S.A.S.ZAC de l’Echangeurrue Saint EloiF-73100 Grésy sur AixPhone +33 4 79348924Fax +33 4 79348923
Far East
France
Gulf
North America
Scanbalt
South America
South Europe
UK/Ireland
DORMA Gulf Door Controls FZEJebel Ali Free Zone SouthPlot No. S 20135Road No. SW 301 GP.O. Box 17268Dubai - United Arab EmiratesPhone +971 4 8020400Fax +971 4 8869100
+971 4 8869101
DORMA Architectural HardwareDORMA Drive, Drawer ACReamstown, PA 17567-0411Phone +1 800 5238483Fax +1 800 2749724
DORMA Sverige ABF O Petersons Gata 24SE-421 31 Västra FrölundaPhone +46 31 289520Fax +46 31 281739
DORMA Sistemas de controlespara Portas Ltda.Av. Piracema, 1400Centro Empresarial TamboreCEP 06400-933 Barueri/São Paulo,BrasilPhone +55 11 46899280Fax +55 11 46899215
South-East EuropaDORMA AUSTRIA GmbHPebering Strass 22A-5301 EugendorfPhone +43 6225 284880Fax +43 6225 28491
DORMA Italiana S.r.l.Via. Canova 44/46I-20035 Lissone (MI)Phone +39 039 244031Fax +39 039 24403310
DORMA Ibérica, S.A.Camino San Martin de la Vega, 4E-28500 Arganda del Rey(Madrid)Phone +34 91 8757850Fax +34 91 8757881
DORMA UK Ltd.Wilbury WayHitchinGB-Hertfordshire SG4 0ABGreat BritainPhone +44 1462 477600Fax +44 1462 477601