power world wide safety emi inrush ocp ovp factor

35
PBA/PBW-1 Feature Small-size & light weight Harmonic attenuator (Complies with IEC61000-3-2) : except PBA1500T Universal input (AC85 - 264V) : PBA1500T(AC170 - 264V 3f) Efficiency increased with synchronous rectification technology (PBA50F - 150F) Variety of option (PBA10F - 150F, PBW15F - 50F) Parallel operation and Parallel redandancy operation (PBA300F - 1500F, PBA1500T) Fan alarm, Remote ON/OFF and other functions (PBA300F - 1500F, PBA1500T) Safety agency approvals UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 UL508 (PBA10F - 150F, -24, with cover) Complies with DEN-AN EMI Complies with FCC-B, CISPR22-B, EN55011-B, EN55022-B, VCCI-B 5-year warranty (refer to Instruction Manual) CE marking Low Voltage Directive RoHS Directive EMS Compliance : EN61204-3, EN61000-6-2 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 AC-DC Power Supplies Enclosed Type Power Factor Correction World wide Safety Approvals EMI Inrush current limiting OCP OVP Remote ON/OFF Parallel Operation PBA , PBW-series June 25, 2020

Upload: others

Post on 19-May-2022

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-1

Feature Small-size & light weight Harmonic attenuator (Complies with IEC61000-3-2) : except PBA1500T Universal input (AC85 - 264V) : PBA1500T(AC170 - 264V 3f) Efficiency increased with synchronous rectification technology (PBA50F - 150F) Variety of option (PBA10F - 150F, PBW15F - 50F) Parallel operation and Parallel redandancy operation (PBA300F - 1500F, PBA1500T) Fan alarm, Remote ON/OFF and other functions (PBA300F - 1500F, PBA1500T)

Safety agency approvals UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 UL508 (PBA10F - 150F, -24, with cover) Complies with DEN-AN

EMI Complies with FCC-B, CISPR22-B, EN55011-B, EN55022-B,

VCCI-B

5-year warranty (refer to Instruction Manual)

CE marking Low Voltage Directive RoHS Directive

EMS Compliance : EN61204-3, EN61000-6-2

EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11

AC-DC Power Supplies Enclosed Type

PowerFactorCorrection

World wide SafetyApprovals

EMI Inrushcurrentlimiting

OCP OVP RemoteON/OFF

ParallelOperation

PBA, PBW-series

June 25, 2020

Page 2: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-2

MODEL PBA10F-5 PBA10F-12 PBA10F-24MAX OUTPUT WATTAGE[W] 10 10.8 12DC OUTPUT 5V 2A 12V 0.9A 24V 0.5A

SPECIFICATIONSMODEL PBA10F-5 PBA10F-12 PBA10F-24

INPUT

VOLTAGE[V] AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *3)

CURRENT[A]ACIN 100V 0.30typ (Io=100%)

ACIN 200V 0.20typ (Io=100%)

FREQUENCY[Hz] 50/60 (47 - 440) or DC

EFFICIENCY[%]ACIN 100V 74typ 76typ 77typACIN 200V 74typ 76typ 77typ

INRUSH CURRENT[A]ACIN 100V 15typ (Io=100%)

ACIN 200V 30typ (Io=100%)

LEAKAGE CURRENT[mA] 0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)

OUTPUT

VOLTAGE[V] 5 12 24CURRENT[A] 2 0.9 0.5LINE REGULATION[mV] 20max 48max 96maxLOAD REGULATION[mV] 40max 100max 150max

RIPPLE[mVp-p]0 to +50C*1 80max 120max 120max-10 - 0C*1

*6

*6

140max 160max 160max

RIPPLE NOISE[mVp-p]0 to +50C*1 120max 150max 150max-10 - 0C*1 160max 180max 180max

TEMPERATURE REGULATION[mV]0 to +50C 50max 120max 240max-10 to +50C 60max 150max 290max

DRIFT[mV] *2 20max 48max 96maxSTART-UP TIME[ms] 200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)

OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 - 5.50 10.0 - 13.2 19.2 - 27.0OUTPUT VOLTAGE SETTING[V] 5.00 - 5.15 12.00 - 12.48 24.00 - 24.96

PROTECTIONCIRCUIT ANDOTHERS

OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 5.75 - 7.00 15.0 - 18.0 30.0 - 37.0OPERATING INDICATION LED (Green)

REMOTE ON/OFF None

ISOLATIONINPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)

INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)

OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)

ENVIRONMENT

OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis

SAFETY ANDNOISEREGULATIONS

AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2 (Not built-in to active filter *4)

OTHERSCASE SIZE/WEIGHT 31X78X68mm [1.22X3.07X2.68 inches] (without terminal block) (WXHXD) / 150g max (with cover : 180g max)

COOLING METHOD Convection

*7

*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).

*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 Derating is required.*4 When two or more units are used,they may not comply with the harmonic attenuator. Please

contact us for details.

*5 Please contact us about safety approvals for the model with option.*6 Please contact us about dynamic load and input response.*7 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.

PBA10FAC-DC Power Supplies Enclosed Type

PB A 10 F -O -O

Ordering information

1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5

C : with Coating G : Low leakage current E : Low leakage current

and EMI class A T : Vertical terminal block J1 : VH (J.S.T.) connector type N : with Cover (UL508 is acquired) N1 : with DIN rail and Cover V : Output voltage setting

potentiometer external-ly

R

1 2 3 4 5 6

High voltage pulse noise type : NAP seriesLow leakage current type : NAM series

Cover is optional

Example recommended EMI/EMC filterNAC-06-472

*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.

*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

June 25, 2020

Page 3: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-3

2.5

Cover name plate

Cover (option)

Name plate

M3

Mounting hole2-M3

Mounting hole2-M3

AC(N)

AC(L)

FG

-V

+V

Terminal coverPoint A:C102

68

34.5

78

15.1±1.5

7.5

9.5

49.5±0.5

36±0.5

16.5±2

31

18

11

34.5

4

22.6±1.5

11.5

18[0.71]

[0.65] [2.68]

[1.95]

[1.42] [0.43]

[0.16][0.59]

[0.89]

[0.1]

[0.48]12.2±1.5

70.5

[2.7

8]

[0.3

][0

.37]

[1.3

6]

[1.3

6]

[1.2

2]

[0.7

1]

[3.0

7]

[0.4

5]

PBA10F

LEDVoltage adjust

¶ Tolerance : ±1 [±0.04]¶ Weight : 150g max (with cover : 180g max)¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.6N • m(6.3kgf • cm)max¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max¶ Please connect safety ground to the unit in 2-M3 holes.

¶ External size of option T,J1,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.

Block diagram

2.5AAC250V

NOISEFILTER

INVERTERCONTROL

CURRENTSENSING

RECTIFIERAND

FILTER

CONTROL

AC IN

DC OUT

FG

Photocoupler

Photocoupler

TRANSFORMER

85 - 264V

INRUSHCURRENT

LIMIT

FUSE

OVER VOLTAGEPROTECTION

RECTIFIERAND

FILTER

External view

PBA10F

June 25, 2020

Page 4: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-4

MODEL PBA15F-3R3 PBA15F-5 PBA15F-9 PBA15F-12 PBA15F-15 PBA15F-24 PBA15F-48MAX OUTPUT WATTAGE[W] 9.9 15 15.3 15.6 15 16.8 16.8DC OUTPUT 3.3V 3A 5V 3A 9V 1.7A 12V 1.3A 15V 1A 24V 0.7A 48V 0.35A

SPECIFICATIONSMODEL PBA15F-3R3 PBA15F-5 PBA15F-9 PBA15F-12 PBA15F-15 PBA15F-24 PBA15F-48

INPUT

VOLTAGE[V] AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *3)

CURRENT[A]ACIN 100V 0.30typ (Io=100%) 0.4typ (Io=100%)

ACIN 200V 0.15typ (Io=100%) 0.2typ (Io=100%)

FREQUENCY[Hz] 50/60 (47 - 440) or DC

EFFICIENCY[%]ACIN 100V 68typ 74typ 75typ 75typ 77typ 75typ 75typACIN 200V 68typ 75typ 77typ 78typ 80typ 78typ 78typ

INRUSH CURRENT[A]ACIN 100V 15typ (Io=100%) (At cold start)

ACIN 200V 30typ (Io=100%) (At cold start)

LEAKAGE CURRENT[mA] 0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)

OUTPUT

VOLTAGE[V] 3.3 5 9 12 15 24 48CURRENT[A] 3 3 1.7 1.3 1 0.7 0.35LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 192maxLOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max

RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max-10 - 0C*1

*6

*6

140max 140max 160max 160max 160max 160max 200max

RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 250max-10 - 0C*1 160max 160max 180max 180max 180max 180max 300max

TEMPERATURE REGULATION[mV]0 to +50C 50max 50max 90max 120max 150max 240max 480max-10 to +50C 60max 60max 120max 150max 180max 290max 600max

DRIFT[mV] *2 20max 20max 36max 48max 60max 96max 192maxSTART-UP TIME[ms] 200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)

OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.60 4.50 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 39.0 - 53.0OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 9.00 - 9.36 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 48.00 - 49.92

PROTECTIONCIRCUIT ANDOTHERS

OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 4.00 - 5.25 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 58.0 - 65.0OPERATING INDICATION LED (Green)

REMOTE ON/OFF None

ISOLATIONINPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)

INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)

OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)

ENVIRONMENT

OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis

SAFETY ANDNOISEREGULATIONS

AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2 (Not built-in to active filter *4)

OTHERSCASE SIZE/WEIGHT 31X78X85mm [1.22X3.07X3.35 inches] (without terminal block) (WXHXD) / 200g max (with cover : 235g max)

COOLING METHOD Convection

*7

*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).

*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 Derating is required.*4 When two or more units are used,they may not comply with the harmonic attenuator. Please

contact us for details.

*5 Please contact us about safety approvals for the model with option.*6 Please contact us about dynamic load and input response.*7 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.

PBA15FAC-DC Power Supplies Enclosed Type

PB A 15 F -O -O

Ordering information

1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5

C : with Coating G : Low leakage current E : Low leakage current

and EMI class A T : Vertical terminal block J1 : VH (J.S.T.) connector type N : with Cover (UL508 is acquired [5V, 12V, 24V]) N1 : with DIN rail and Cover V : Output voltage setting

potentiometer external-ly

R

1 2 3 4 5 6

High voltage pulse noise type : NAP seriesLow leakage current type : NAM series

Cover is optional

Example recommended EMI/EMC filterNAC-06-472

*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.

*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

June 25, 2020

Page 5: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-5

2.5

Point A:C102

Cover (option)

Name plate

M3

Mounting hole2-M3

Mounting hole2-M3

AC(N)

AC(L)

FG

-V

+V

Terminal cover15.1±1.5

5

18

31

34.5

34.5

78

36.5

11.5

8516.5±2

70.5

12.2±1.5

18

22.6±1.5

31±0.5

60±0.5

9.5

7.5

PBA15FPBW15F

LEDVoltage adjust

Cover name plate

¶ Tolerance : ±1 [±0.04]¶ Weight : 200g max (with cover : 235g max)¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.6N • m(6.3kgf • cm)max¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max¶ Please connect safety ground to the unit in 2-M3 holes.

¶ External size of option T,J1,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.

[0.71]

[0.65] [3.35]

[1.22]

[2.36] [0.2]

[1.44][0.59]

[0.89]

[0.1]

[0.48]

[2.7

8]

[0.3

][0

.37]

[1.3

6]

[1.3

6]

[1.2

2]

[0.7

1]

[3.0

7]

[0.4

5]

Block diagram

2.5AAC250V

AC IN

DC OUT

FG

85 - 264VNOISEFILTER

INVERTERCONTROL

CURRENTSENSING

RECTIFIERAND

FILTER

CONTROL

Photocoupler

Photocoupler

TRANSFORMER

INRUSHCURRENT

LIMIT

FUSE

OVER VOLTAGEPROTECTION

RECTIFIERAND

FILTER

External view

PBA15F

June 25, 2020

Page 6: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-6

MODEL PBA30F-3R3 PBA30F-5 PBA30F-9 PBA30F-12 PBA30F-15 PBA30F-24 PBA30F-48MAX OUTPUT WATTAGE[W] 19.8 30 30.6 30 30 31.2 31.2DC OUTPUT 3.3V 6A 5V 6A 9V 3.4A 12V 2.5A 15V 2A 24V 1.3A 48V 0.65A

SPECIFICATIONSMODEL PBA30F-3R3 PBA30F-5 PBA30F-9 PBA30F-12 PBA30F-15 PBA30F-24 PBA30F-48

INPUT

VOLTAGE[V] AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *3)

CURRENT[A]ACIN 100V 0.50typ (Io=100%) 0.70typ (Io=100%)

ACIN 200V 0.30typ (Io=100%) 0.40typ (Io=100%)

FREQUENCY[Hz] 50/60 (47 - 440) or DC

EFFICIENCY[%]ACIN 100V 68typ 74typ 75typ 76typ 78typ 78typ 79typACIN 200V 69typ 77typ 77typ 78typ 81typ 81typ 81typ

INRUSH CURRENT[A]ACIN 100V 15typ (Io=100%) (At cold start)

ACIN 200V 30typ (Io=100%) (At cold start)

LEAKAGE CURRENT[mA] 0.30/0.65max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)

OUTPUT

VOLTAGE[V] 3.3 5 9 12 15 24 48CURRENT[A] 6 6 3.4 2.5 2 1.3 0.65LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 192maxLOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max

RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max-10 - 0C*1

*6

*6

140max 140max 160max 160max 160max 160max 200max

RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 250max-10 - 0C*1 160max 160max 180max 180max 180max 180max 300max

TEMPERATURE REGULATION[mV]0 to +50C 50max 50max 90max 120max 150max 240max 480max-10 to +50C 60max 60max 120max 150max 180max 290max 600max

DRIFT[mV] *2 20max 20max 36max 48max 60max 96max 192maxSTART-UP TIME[ms] 200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)

OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.60 4.50 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 39.0 - 53.0OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 9.00 - 9.36 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 48.00 - 49.92

PROTECTIONCIRCUIT ANDOTHERS

OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 4.00 - 5.25 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 58.0 - 65.0OPERATING INDICATION LED (Green)

REMOTE ON/OFF None

ISOLATIONINPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)

INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)

OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)

ENVIRONMENT

OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis

SAFETY ANDNOISEREGULATIONS

AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2 (Not built-in to active filter *4)

OTHERSCASE SIZE/WEIGHT 31X78X103mm [1.22X3.07X4.06 inches] (without terminal block) (WXHXD) / 270g max (with cover : 310g max)

COOLING METHOD Convection

*7

*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).

*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 Derating is required.*4 When two or more units are used,they may not comply with the harmonic attenuator. Please

contact us for details.

*5 Please contact us about safety approvals for the model with option.*6 Please contact us about dynamic load and input response.*7 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.

PBA30FAC-DC Power Supplies Enclosed Type

PB A 30 F -O -O

Ordering information

1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5

C : with Coating G : Low leakage current E : Low leakage current

and EMI class A T : Vertical terminal block J1 : VH (J.S.T.) connector type N : with Cover (UL508 is acquired [5V, 12V, 24V]) N1 : with DIN rail and Cover V : Output voltage setting

potentiometer external-ly

R

1 2 3 4 5 6

High voltage pulse noise type : NAP seriesLow leakage current type : NAM series

Cover is optional

Example recommended EMI/EMC filterNAC-06-472

*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.

*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

June 25, 2020

Page 7: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-7

2.5

Terminal cover

+V

-V

FG

AC(L)

AC(N)

M3

Name plate

Cover (option)

Cover name plate

Point A:C102

2-M3Mounting hole

2-M3Mounting hole

15.1±1.5

22.6±1.5

8.575±0.5

40.546±0.5

36.5

16.5±2

11.5

9.5

7.5

18

70.5

12.2±1.5

18

78

103

31

34.5

PBA30FPBW30F

¶ Tolerance : ±1 [±0.04]¶ Weight : 270g max (with cover : 310g max)¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.6N • m(6.3kgf • cm)max¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max¶ Please connect safety ground to the unit in 2-M3 holes.

¶ External size of option T,J1,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.

LEDVoltage adjust [0.71]

[0.65] [4.06]

[1.81]

[2.95] [0.33]

[1.59][0.59]

[0.89]

[0.1]

[0.48]

[2.7

8]

[0.3

][0

.37]

[1.4

4]

[1.3

6]

[1.2

2]

[0.7

1]

[3.0

7]

[0.4

5]

Block diagram

3.15AAC250V

AC IN

DC OUT

FG

85 - 264VNOISEFILTER

INVERTERCONTROL

CURRENTSENSING

RECTIFIERAND

FILTER

RECTIFIERAND

FILTER

CONTROL

Photocoupler

Photocoupler

TRANSFORMER

INRUSHCURRENT

LIMIT

FUSE

OVER VOLTAGEPROTECTION

External view

PBA30F

June 25, 2020

Page 8: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-8

MODEL PBA50F-3R3 PBA50F-5 PBA50F-9 PBA50F-12 PBA50F-15 PBA50F-24 PBA50F-36 PBA50F-48MAX OUTPUT WATTAGE[W] 33 50 50.4 51.6 52.5 52.8 50.4 52.8DC OUTPUT 3.3V 10A 5V 10A 9V 5.6A 12V 4.3A 15V 3.5A 24V 2.2A 36V 1.4A 48V 1.1A

SPECIFICATIONSMODEL PBA50F-3R3 PBA50F-5 PBA50F-9 PBA50F-12 PBA50F-15 PBA50F-24 PBA50F-36 PBA50F-48

INPUT

VOLTAGE[V] AC85 - 264 1f or DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *4)

CURRENT[A]ACIN 100V 0.5typ 0.7typACIN 200V 0.3typ 0.4typ

FREQUENCY[Hz] 50/60 (47 - 63)

EFFICIENCY[%]ACIN 100V 75typ 80typ 79typ 80typ 81typ 82typ 83typ 83typACIN 200V 76typ 82typ 81typ 82typ 83typ 84typ 85typ 85typ

POWER FACTOR(Io=100%) ACIN 100V 0.98typ 0.99typACIN 200V 0.87typ 0.93typ

INRUSH CURRENT[A]ACIN 100V 15typ (Io=100%) (At cold start)ACIN 200V 30typ (Io=100%) (At cold start)

LEAKAGE CURRENT[mA] 0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)

OUTPUT

VOLTAGE[V] 3.3 5 9 12 15 24 36 48CURRENT[A] 10 10 5.6 4.3 3.5 2.2 1.4 1.1LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192maxLOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max

RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max 150max-10 - 0C*1 140max 140max 160max 160max 160max 160max 200max 200max

RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 250max 250max-10 - 0C*1 160max 160max 180max 180max 180max 180max 300max 300max

TEMPERATURE REGULATION[mV]0 to +50C 50max 50max 90max 120max 150max 240max 360max 480max-10 to +50C 60max 60max 120max 150max 180max 290max 450max 600max

DRIFT[mV] *2 20max 20max 36max 48max 60max 96max 144max 192maxSTART-UP TIME[ms] 350typ(ACIN 100V, Io=100%)HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.63 4.00 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 28.8 - 39.6 39.0 - 53.0OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 9.00 - 9.36 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 35.00 - 37.44 48.00 - 49.92

PROTECTIONCIRCUIT ANDOTHERS

OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 4.00 - 5.25 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 43.0 - 50.0 58.0 - 65.0OPERATING INDICATION LED (Green)REMOTE ON/OFF Optional (Required external power source)

ISOLATIONINPUT-OUTPUT-RC *3 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-FG *3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)

ENVIRONMENT

OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis

SAFETY ANDNOISEREGULATIONS

AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2

OTHERSCASE SIZE/WEIGHT 31X82X120mm [1.22X3.23X4.72 inches] (without terminal block) (WXHXD) / 280g max (with cover : 325g max)COOLING METHOD Convection

*6

*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).

*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and

FG.*4 Derating is required.

*5 Please contact us about safety approvals for the model with option.*6 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.

PBA50FAC-DC Power Supplies Enclosed Type

PB A 50 F -5 -O

Ordering information

1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5

C : with Coating G : Low leakage current (0.15mA max / ACIN 240V) E : Low leakage current

and EMI class A (0.5mA max / ACIN 240V) T : Vertical terminal block J1 : VH (J.S.T.) connector type R : with Remote ON/OFF N : with Cover (Only 24V UL508 is acquired) N1 : with DIN rail and Cover V : Output voltage setting

potentiometer external-ly

R

1 2 3 4 5 6

High voltage pulse noise type : NAP seriesLow leakage current type : NAM series

Cover is optional

Example recommended EMI/EMC filterNAC-06-472

*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.

*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

June 25, 2020

Page 9: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-9

Block diagram

FG

INRUSHCURRENT

LIMIT

RECTIFIERAND

FILTER

CONTROL

TRANSFORMER

CONTROL

OVER VOLTAGEPROTECTION

DC OUT

NOISEFILTER

RECTIFIERAND

FILTER

INVERTER

AC IN 85 - 264V

FUSE

RECTIFIER

CURRENTSENSING

BOOSTERINDUCTOR

INVERTER

CONTROL

CURRENTSENSING

RC

EXTERNALSOURCE

E

OPTION

250V2A

External view

PBA50F

PBA50F

A

M3

2-M3

2-M3

AC(N)

AC(L)

-V

+V

35

120

1 2

(16.5)

(21.5)

(14)

(20)

(12)

820.

5

4

(71)

77±0.5

9.5

7.5

(11)

88±0.5 11

18

313.

5

Point A

Terminal cover

Mounting hole

Mountinghole

Voltage adjust

Name plate

LED

Cover (option)

CN3Connector for Remote ON/OFF (option)

¶ Tolerance : ±1 [±0.04]

¶ External size of option T,J1,R,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.

¶ Weight : 280g max (with cover : 325g max)¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.49N • m(5kgf • cm)max¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max

FG

¶ Please connect safety ground to the unit in 2-M3 holes.

Pin No. Contents12

RC(+)RC( - )

CN3 Option (Mfr : J.S.T.)

Connector type

Model B2B-XH-AMating Connector (Terminal)XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6

Barrier strip type

[0.79]

[0.65] [4.72]

[3.03] [0.16][0.55]

[0.85]

[0.43]

[2.8

]

[0.3

][0

.37]

[1.3

8]

[3.2

3][0

.02]

[0.4

7]

[3.46] [0.43]

[1.2

2]

[0.7

1]

[0.1

4]

( )

June 25, 2020

Page 10: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-10

MODEL PBA75F-3R3 PBA75F-5 PBA75F-9 PBA75F-12 PBA75F-15 PBA75F-24 PBA75F-36 PBA75F-48MAX OUTPUT WATTAGE[W] 49.5 75 75.6 75.6 75 76.8 75.6 76.8DC OUTPUT 3.3V 15A 5V 15A 9V 8.4A 12V 6.3A 15V 5A 24V 3.2A 36V 2.1A 48V 1.6A

SPECIFICATIONSMODEL PBA75F-3R3 PBA75F-5 PBA75F-9 PBA75F-12 PBA75F-15 PBA75F-24 PBA75F-36 PBA75F-48

INPUT

VOLTAGE[V] AC85 - 264 1f or DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *4)

CURRENT[A]ACIN 100V 0.7typ 1.0typACIN 200V 0.4typ 0.5typ

FREQUENCY[Hz] 50/60 (47 - 63)

EFFICIENCY[%]ACIN 100V 77typ 81typ 80typ 81typ 82typ 83typ 84typ 84typACIN 200V 78typ 83typ 82typ 83typ 84typ 85typ 86typ 86typ

POWER FACTOR(Io=100%) ACIN 100V 0.98typ 0.99typACIN 200V 0.87typ 0.93typ

INRUSH CURRENT[A]ACIN 100V 15typ (Io=100%) (At cold start)ACIN 200V 30typ (Io=100%) (At cold start)

LEAKAGE CURRENT[mA] 0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)

OUTPUT

VOLTAGE[V] 3.3 5 9 12 15 24 36 48CURRENT[A] 15 15 8.4 6.3 5 3.2 2.1 1.6LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192maxLOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max

RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max 150max-10 - 0C*1 140max 140max 160max 160max 160max 160max 200max 200max

RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 250max 250max-10 - 0C*1 160max 160max 180max 180max 180max 180max 300max 300max

TEMPERATURE REGULATION[mV]0 to +50C 50max 50max 90max 120max 150max 240max 360max 480max-10 to +50C 60max 60max 120max 150max 180max 290max 450max 600max

DRIFT[mV] *2 20max 20max 36max 48max 60max 96max 144max 192maxSTART-UP TIME[ms] 350typ(ACIN 100V, Io=100%)HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.63 4.00 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 28.8 - 39.6 39.0 - 53.0OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 9.00 - 9.36 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92

PROTECTIONCIRCUIT ANDOTHERS

OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 4.00 - 5.25 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 43.0 - 50.0 58.0 - 65.0OPERATING INDICATION LED (Green)REMOTE ON/OFF Optional (Required external power source)

ISOLATIONINPUT-OUTPUT-RC *3 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-FG *3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)

ENVIRONMENT

OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis

SAFETY ANDNOISEREGULATIONS

AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2

OTHERSCASE SIZE/WEIGHT 32X82X135mm [1.26X3.23X5.31 inches] (without terminal block) (WXHXD) / 350g max (with cover : 400g max)COOLING METHOD Convection

*6

*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).

*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and

FG.*4 Derating is required.

*5 Please contact us about safety approvals for the model with option.*6 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.

PBA75FAC-DC Power Supplies Enclosed Type

PB A 75 F -5 -O

Ordering information

1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5

C : with Coating G : Low leakage current (0.15mA max / ACIN 240V) E : Low leakage current

and EMI class A (0.5mA max / ACIN 240V) T : Vertical terminal block J1 : VH (J.S.T.) connector type R : with Remote ON/OFF N : with Cover (Only 24V UL508 is acquired) N1 : with DIN rail and Cover V : Output voltage setting

potentiometer external-ly

R

1 2 3 4 5 6

High voltage pulse noise type : NAP seriesLow leakage current type : NAM series

Cover is optional

Example recommended EMI/EMC filterNAC-06-472

*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.

*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

June 25, 2020

Page 11: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-11

[0.79]

[0.55]

[0.85]

[0.43]

[2.8

]

[0.65] [5.31]

[3.7] [0.16]

[0.3

][0

.37]

[1.3

8]

[3.2

3][0

.02]

[0.4

7]

[4.15] [0.35]

[1.2

6]

[0.7

1]

[0.1

4]

Point A

A

Terminal cover

M3

Mounting hole2-M3

Voltage adjust

AC(N)

AC(L)

-V

+V

¶ Tolerance : ±1 [±0.04]¶ Weight : 350g max (with cover : 400g max)¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.49N • m(5kgf • cm)max¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max

Name plate

32

18

9105.5±0.5

(16.5)

494±0.5

35

135

(21.5)

(14)

(20)

(11)

82

(12)

(71)

9.5

7.5

PBA75F

LED

Pin No. Contents12

RC(+)RC( - )

CN3 Option (Mfr : J.S.T.)

Connector type

Model B2B-XH-AMating Connector (Terminal)XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6

Barrier strip type

¶ External size of option T,J1,R,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.0.

53.

5

CN3Connector for Remote ON/OFF (option)

Cover (option)

FG

¶ Please connect safety ground to the unit in 2-M3 holes.

1 2

2-M3Mountinghole

( )

Block diagram

FG

DC OUT

AC IN 85 - 264V

RC

E

250V3.15A INRUSHCURRENT

LIMIT

RECTIFIERAND

FILTER

CONTROL

TRANSFORMER

CONTROL

OVER VOLTAGEPROTECTION

NOISEFILTER

RECTIFIERAND

FILTER

INVERTER

FUSE

RECTIFIER

CURRENTSENSING

BOOSTERINDUCTOR

INVERTER

CONTROL

CURRENTSENSING

EXTERNALSOURCE

OPTION

External view

PBA75F

June 25, 2020

Page 12: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-12

MODEL PBA100F-3R3 PBA100F-5 PBA100F-9 PBA100F-12 PBA100F-15 PBA100F-24 PBA100F-36 PBA100F-48MAX OUTPUT WATTAGE[W] 66 100 94.5 102 105 108 100.8 100.8DC OUTPUT 3.3V 20A 5V 20A 9V 10.5A 12V 8.5A 15V 7A 24V 4.5A 36V 2.8A 48V 2.1A

SPECIFICATIONSMODEL PBA100F-3R3 PBA100F-5 PBA100F-9 PBA100F-12 PBA100F-15 PBA100F-24 PBA100F-36 PBA100F-48

INPUT

VOLTAGE[V] AC85 - 264 1f or DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *4)

CURRENT[A]ACIN 100V 0.9typ 1.3typACIN 200V 0.5typ 0.7typ

FREQUENCY[Hz] 50/60 (47 - 63)

EFFICIENCY[%]ACIN 100V 77typ 82typ 80typ 81typ 83typ 84typ 84typ 84typACIN 200V 79typ 84typ 82typ 83typ 86typ 86typ 86typ 86typ

POWER FACTOR(Io=100%) ACIN 100V 0.98typ 0.99typACIN 200V 0.87typ 0.93typ

INRUSH CURRENT[A]ACIN 100V 20typ (Io=100%) (At cold start)ACIN 200V 40typ (Io=100%) (At cold start)

LEAKAGE CURRENT[mA] 0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)

OUTPUT

VOLTAGE[V] 3.3 5 9 12 15 24 36 48CURRENT[A] 20 20 10.5 8.5 7 4.5 2.8 2.1LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192maxLOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max

RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max 150max-10 - 0C*1 140max 140max 160max 160max 160max 160max 200max 200max

RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 250max 250max-10 - 0C*1 160max 160max 180max 180max 180max 180max 300max 300max

TEMPERATURE REGULATION[mV]0 to +50C 50max 50max 90max 120max 150max 240max 360max 480max-10 to +50C 60max 60max 120max 150max 180max 290max 450max 600max

DRIFT[mV] *2 20max 20max 36max 48max 60max 96max 144max 192maxSTART-UP TIME[ms] 350typ(ACIN 100V, Io=100%)HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.63 4.00 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 28.8 - 39.6 39.0 - 53.0OUTPUT VOLTAGE SETTING[V] 3.20 - 3.40 5.00 - 5.15 9.00 - 9.36 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92

PROTECTIONCIRCUIT ANDOTHERS

OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 4.00 - 5.25 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 43.0 - 50.0 58.0 - 65.0OPERATING INDICATION LED (Green)REMOTE SENSING Optional (Only -3R3, -5 Option -K)REMOTE ON/OFF Optional (Required external power source)

ISOLATIONINPUT-OUTPUT-RC *3 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-FG *3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)

ENVIRONMENT

OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis

SAFETY ANDNOISEREGULATIONS

AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2

OTHERSCASE SIZE/WEIGHT 32X93X147mm [1.26X3.66X5.79 inches] (without terminal block) (WXHXD) / 440g max (with cover : 500g max)COOLING METHOD Convection

*6

*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).

*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and

FG.*4 Derating is required.

*5 Please contact us about safety approvals for the model with option.*6 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.

PBA100FAC-DC Power Supplies Enclosed Type

PB A 100 F -5 -O

Ordering information

1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5

C : with Coating G : Low leakage current (0.15mA max / ACIN 240V) E : Low leakage current

and EMI class A (0.5mA max / ACIN 240V) T : Vertical terminal block J1 : VH (J.S.T.) connector type (Only -12,-15,-24,-36,-48) R : with Remote ON/OFF N : with Cover (Only 24V UL508 is acquired) N1 : with DIN rail and Cover V : Output voltage setting

potentiometer external-ly

R

1 2 3 4 5 6

High voltage pulse noise type : NAP seriesLow leakage current type : NAM series

Cover is optional

Example recommended EMI/EMC filterNAC-06-472

*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.

*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

June 25, 2020

Page 13: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-13

A

3-M3

2-M3

M4

AC(N)

AC(L)

-V

-V

+V

+V

Name plate

32

13±0

.59.

5

15112.5 ±0.5

(13.5)

124±0.5

33.5

4

(11)

(20)

(81)

(23.5)

(14)

93

(10)

147

8.6

1018

PBA100F¶ Tolerance : ±1 [±0.04]¶ Weight : 440g max (with cover : 500g max)¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.49N • m(5kgf • cm)max¶ Mounting torque : M4:1.6N • m(16.9kgf • cm)max

Point A

Terminal cover

Mounting hole

Mountinghole

Voltage adjustLED

¶ External size of option T,J1,R,N1,V and K is different from standard model and refer to 7 Option of instruction manual for details.0.

53.

5

CN4Connector for Remote sensing (option : only -3R3, -5)

CN3Connector for Remote ON/OFF (option)

Cover (option)

FG( )

¶ Please connect safety ground to FG terminal on the unit.

1 2

Pin No. Contents12

RC(+)RC( - )

CN3 Option (Mfr : J.S.T.)

Connector type

Model B2B-XH-AMating Connector (Terminal)XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6

Barrier strip type

[0.79]

[0.55]

[0.93]

[0.43]

[3.1

9]

[0.53] [5.79]

[4.88] [0.16]

[0.3

4][0

.39]

[1.3

2]

[3.6

6][0

.02]

[0.3

9][0

.71]

[4.43] [0.59]

[1.2

6]

[0.5

1][0

.37]

[0.1

4]

( )

Block diagram

FG

DC OUT

AC IN 85 - 264V

RC

E

250V3.15A INRUSHCURRENT

LIMIT

RECTIFIERAND

FILTER

CONTROL

TRANSFORMER

CONTROL

OVER VOLTAGEPROTECTION

NOISEFILTER

RECTIFIERAND

FILTER

INVERTER

FUSE

RECTIFIER

CURRENTSENSING

BOOSTERINDUCTOR

INVERTER

CONTROL

CURRENTSENSING

EXTERNALSOURCE

OPTION

External view

PBA100F

June 25, 2020

Page 14: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-14

MODEL PBA150F-3R3 PBA150F-5 PBA150F-9 PBA150F-12 PBA150F-15 PBA150F-24 PBA150F-36 PBA150F-48MAX OUTPUT WATTAGE[W] 99 150 150.3 156 150 156 154.8 158.4DC OUTPUT 3.3V 30A 5V 30A 9V 16.7A 12V 13A 15V 10A 24V 6.5A 36V 4.3A 48V 3.3A

SPECIFICATIONSMODEL PBA150F-3R3 PBA150F-5 PBA150F-9 PBA150F-12 PBA150F-15 PBA150F-24 PBA150F-36 PBA150F-48

INPUT

VOLTAGE[V] AC85 - 264 1f or DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *4)

CURRENT[A]ACIN 100V 1.3typ 2.0typACIN 200V 0.7typ 1.0typ

FREQUENCY[Hz] 50/60 (47 - 63)

EFFICIENCY[%]ACIN 100V 80typ 83typ 82typ 83typ 84typ 85typ 85typ 85typACIN 200V 82typ 86typ 85typ 86typ 87typ 88typ 88typ 88typ

POWER FACTOR(Io=100%) ACIN 100V 0.98typ 0.99typACIN 200V 0.87typ 0.93typ

INRUSH CURRENT[A]ACIN 100V 20typ (Io=100%) (At cold start)ACIN 200V 40typ (Io=100%) (At cold start)

LEAKAGE CURRENT[mA] 0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)

OUTPUT

VOLTAGE[V] 3.3 5 9 12 15 24 36 48CURRENT[A] 30 30 16.7 13 10 6.5 4.3 3.3LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192maxLOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max

RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max 150max-10 - 0C*1 140max 140max 160max 160max 160max 160max 200max 200max

RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 250max 250max-10 - 0C*1 160max 160max 180max 180max 180max 180max 300max 300max

TEMPERATURE REGULATION[mV]0 to +50C 50max 50max 90max 120max 150max 240max 360max 480max-10 to +50C 60max 60max 120max 150max 180max 290max 450max 600max

DRIFT[mV] *2 20max 20max 36max 48max 60max 96max 144max 192maxSTART-UP TIME[ms] 350typ(ACIN 100V, Io=100%)HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.63 4.00 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 28.8 - 39.6 39.0 - 53.0OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 9.00 - 9.36 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92

PROTECTIONCIRCUIT ANDOTHERS

OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 4.00 - 5.25 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 43.0 - 50.0 58.0 - 65.0OPERATING INDICATION LED (Green)REMOTE SENSING Optional (Only -3R3, -5 Option -K)REMOTE ON/OFF Optional (Required external power source)

ISOLATIONINPUT-OUTPUT-RC *3 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-FG *3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)

ENVIRONMENT

OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis

SAFETY ANDNOISEREGULATIONS

AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2

OTHERSCASE SIZE/WEIGHT 34X93X168mm [1.34X3.66X6.61 inches] (without terminal block) (WXHXD) / 560g max (with cover : 630g max)COOLING METHOD Convection

*6

*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).

*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and

FG.*4 Derating is required.

*5 Please contact us about safety approvals for the model with option.*6 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.

PBA150FAC-DC Power Supplies Enclosed Type

PB A 150 F -5 -O

Ordering information

1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5

C : with Coating G : Low leakage current (0.15mA max / ACIN 240V) E : Low leakage current

and EMI class A (0.5mA max / ACIN 240V) T : Vertical terminal block J1 : VH (J.S.T.) connector type (Only -12,-15,-24,-36,-48) R : with Remote ON/OFF N : with Cover (Only 24V UL508 is acquired) N1 : with DIN rail and Cover V : Output voltage setting

potentiometer external-ly

R

1 2 3 4 5 6

High voltage pulse noise type : NAP seriesLow leakage current type : NAM series

Cover is optional

Example recommended EMI/EMC filterNAC-06-472

*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.

*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

June 25, 2020

Page 15: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-15

PBA150F

9

9334

19

(13.5) 168

58.5

37.5

78±0.5 2-M3

2-M3

TB1

M4+V

+V

-V

-V

AC(L)

AC(N)

A

139.5±0.5

108.

6

(81)

(14.5)

(20.5)[0.81]

[0.57]

[0.53] [6.61]

[3.07]

[5.49] [0.35]

[2.3]

[0.94]

[3.1

9]

[1.4

8][0

.75] [1

.34]

[3.6

6][0

.02]

[0.3

4][0

.39]

[0.3

9]

[0.1

4]

(11.5)[0.45]

(24)

(10)

¶ Tolerance : ±1 [±0.04]¶ Weight : 560g max (with cover : 630g max)

¶ Keep drawing current per pin below 20A for TB1.

¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.49N • m(5kgf • cm)max¶ Mounting torque : M4:1.6N • m(16.9kgf • cm)max

Name plate

Point A

Terminal cover

Mounting hole

Mountinghole

Voltage adjust LED

¶ External size of option T,J1,R,N1,V and K is different from standard model and refer to 7 Option of instruction manual for details.

0.5

3.5

CN4Connector for Remote sensing (option : only -3R3, -5)

CN3Connector for Remote ON/OFF (option)

Cover (option)

FG( )

¶ Please connect safety ground to FG terminal on the unit.

1 2

Pin No. Contents12

RC(+)RC( - )

CN3 Option (Mfr : J.S.T.)

Connector type

Model B2B-XH-AMating Connector (Terminal)XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6

Barrier strip type

( )

Block diagram

FG

DC OUT

AC IN 85 - 264V

RC

E

250V4A INRUSHCURRENT

LIMIT

RECTIFIERAND

FILTER

CONTROL

TRANSFORMER

CONTROL

OVER VOLTAGEPROTECTION

NOISEFILTER

RECTIFIERAND

FILTER

INVERTER

FUSE

RECTIFIER

CURRENTSENSING

BOOSTERINDUCTOR

INVERTER

CONTROL

CURRENTSENSING

EXTERNALSOURCE

OPTION

External view

PBA150F

June 25, 2020

Page 16: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-16

MODEL PBA300F-3R3 PBA300F-5 PBA300F-7R5 PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 PBA300F-48MAX OUTPUT WATTAGE[W] 198 300 300 324 330 336 324 336

DC OUTPUTACIN 100V 3.3V 60A 5V 60A 7.5V 40A 12V 27A 15V 22A 24V 14A 36V 9A 48V 7AACIN 200V*3 3.3V 60A 5V 60A 7.5V 40A 12V 27A 15V 22A 24V 14(16.5)A 36V 9A 48V 7A

SPECIFICATIONSMODEL PBA300F-3R3 PBA300F-5 PBA300F-7R5 PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 PBA300F-48

INPUT

VOLTAGE[V] AC85 - 264 1f or DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *4)

CURRENT[A]ACIN 100V 3typ 4.1typACIN 200V 1.6typ 2typ

FREQUENCY[Hz] 50/60 (47 - 63)

EFFICIENCY[%]ACIN 100V 68typ 74typ 76typ 78typ 78typ 79typ 81typ 79typACIN 200V 71typ 77typ 79typ 81typ 81typ 82typ 84typ 82typ

POWER FACTORACIN 100V 0.98typ (Io=100%)ACIN 200V 0.95typ (Io=100%)

INRUSH CURRENT[A]ACIN 100V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)ACIN 200V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)

LEAKAGE CURRENT[mA] 0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)

OUTPUT

VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48

CURRENT[A]ACIN 100V 60 60 40 27 22 14 9 7ACIN 200V*3 60 60 40 27 22 14(16.5) 9 7

LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192maxLOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max

RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max 150max-20 - 0C*1 140max 140max 160max 160max 160max 160max 160max 400max

RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 200max 200max-20 - 0C*1 160max 160max 180max 180max 180max 180max 240max 500max

TEMPERATURE REGULATION[mV]0 to +50C 40max 50max 75max 120max 150max 240max 360max 480max-20 to +50C 60max 75max 120max 180max 180max 290max 440max 600max

DRIFT[mV] *2 12max 20max 30max 48max 60max 96max 144max 192maxSTART-UP TIME[ms] 300typ(ACIN 100/200V, Io=100%) *Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms] 20typ (ACIN 100/200V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92

PROTECTIONCIRCUIT ANDOTHERS

OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 4.3 - 6.3 6.5 - 8.0 9.0 - 11.6 14.4 - 18.6 18.0 - 23.3 28.8 - 37.2 43.2 - 54.0 57.6 - 80.0OPERATING INDICATION LED (Green)REMOTE SENSING ProvidedREMOTE ON/OFF Provided

ISOLATION

INPUT-OUTPUT-RC AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-AUX-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-AUX AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)

ENVIRONMENT

OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis

SAFETY ANDNOISEREGULATIONS

AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2

OTHERSCASE SIZE/WEIGHT 102X42X170mm [4.02X1.65X6.69 inches] (without terminal block and screw) (WXHXD) /1.0kg maxCOOLING METHOD Forced cooling (internal fan)

*6

*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).

*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual

in detail.*4 Derating is required.Consult us for details.

*5 Please contact us about safety approvals for the model with option.*6 Please contact us about class C.* A sound may occur from power supply at pulse loading.

PBA300FAC-DC Power Supplies Enclosed Type

PB A 300 F -5 -O

Ordering information

1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5

C : with Coating G : Low leakage current U : Operation stop voltage

is set at a lower value F3 : Reverse air exhaust

type F4 : Low speed fan N1 :with DIN rail

Refer to instruction manual 7.1.

R

1 2 3 4 5 6

High voltage pulse noise type : NAP seriesLow leakage current type : NAM series

Example recommended EMI/EMC filterNAC-06-472

*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.

*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

June 25, 2020

Page 17: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-17

2-M4

4-M4Mounting Hole

Name plateCN1

Output voltageadjustable potentiometer

LED

Terminal cover

CN2CN3

Name plateM4

M4

Output terminal(+)

Output terminal(-)

AC(N)AC(L)

AIR FLOW¶ Tolerance : ±1 [±0.04]¶ Weight : 1.0kg max¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 1.2N • m max¶ Screw tightening torque : 1.6N • m max¶ The housing for the remote sensing unused is mounted on CN1

170 6max

50.5

102

42

(14)

(15.5)

8.6

(23.

5)

25max

(87)

(30)

28.5[1.12][0.61]

[0.55]

[1.18]

[2.52]

[2.91][2.13]

[0.98]

[6.69] [0.24]

[1.6

5][1

.99]

[3.4

3][2.9

5]

[0.9

3]

[1.9

7]

[0.4

7]

[0.4

7]

[0.3

4]

[0.3

9][0

.28]

[0.2

4]

[4.0

2]

[0.7

9][0

.47]

64±0.5

(6)

107

(50)

12

1220

±0.5

54 74±0.5

(75)

12

HV

.AD

J

¶ Please connect safety ground to FG terminal on the unit.

FG( )

Mounting Hole(Bottom side)

Block diagram

250V10A

INRUSHCURRENT

LIMITRECTIFIER

DC OUT

RC(REMOTE ON / OFF)

VB(VOLTAGE BALANCE)

CB(CURRENT BALANCE)

PG(POWER GOOD)

AUX(12V 0.1A)

±M

±S(REMOTE SENSING)

NOISEFILTER

SWITCHINGDEVICE

CONTROL

RECTIFIERAND

FILTER

RECTIFIERAND

FILTER

VOLTAGESENSING

ACTIVE FILTER

VOLTAGESENSING

CURRENTSENSING

INVERTER

CONTROL

ALARMFANINTERNALREGULATOR

CONTROL

MASTERSLAVE

CONTROL

THERMALPROTECTION

CURRENTSENSING

AC IN

FG

FUSE

85 - 264V

OVER VOLTAGEPROTECTION

External view

PBA300F

June 25, 2020

Page 18: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-18

MODEL PBA600F-3R3 PBA600F-5 PBA600F-7R5 PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 PBA600F-48MAX OUTPUT WATTAGE[W] 396 600 600 636 645 648 648 624

DC OUTPUTACIN 100V 3.3V 120A 5V 120A 7.5V 80A 12V 53A 15V 43A 24V 27A 36V 18A 48V 13AACIN 200V*3 3.3V 120A 5V 120A 7.5V 80A 12V 53A 15V 43A 24V 27(31)A 36V 18A 48V 13A

SPECIFICATIONSMODEL PBA600F-3R3 PBA600F-5 PBA600F-7R5 PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 PBA600F-48

INPUT

VOLTAGE[V] AC85 - 264 1f or DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *5)

CURRENT[A]ACIN 100V 5.8typ 8.2typACIN 200V 3typ 4.1typ

FREQUENCY[Hz] 50/60 (47 - 63)

EFFICIENCY[%]ACIN 100V 70typ 75typ 76typ 79typ 79typ 81typ 82typ 81typACIN 200V 72typ 77typ 79typ 82typ 82typ 84typ 84typ 83typ

POWER FACTORACIN 100V 0.98typ (Io=100%)ACIN 200V 0.95typ (Io=100%)

INRUSH CURRENT[A]ACIN 100V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)ACIN 200V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)

LEAKAGE CURRENT[mA] 0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1, DENAN)

OUTPUT

VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48

CURRENT[A]ACIN 100V 120 120 80 53 43 27 18 13ACIN 200V*3 120 120 80 53 43 27(31) 18 13

LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192maxLOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max

RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max 150max-20 - 0C*1 140max 140max 160max 160max 160max 160max 160max 400max

RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 200max 200max-20 - 0C*1 160max 160max 180max 180max 180max 180max 240max 500max

TEMPERATURE REGULATION[mV]0 to +50C 40max 50max 75max 120max 150max 240max 360max 480max-20 to +50C 60max 75max 120max 180max 180max 290max 440max 600max

DRIFT[mV] *2 12max 20max 30max 48max 60max 96max 144max 192maxSTART-UP TIME[ms] 400typ(ACIN 100/200V, Io=100%) *Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms] 20typ (ACIN 100/200V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92

PROTECTIONCIRCUIT ANDOTHERS

OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automaticallyOVERVOLTAGE PROTECTION[V] *4 Vo+0.66 - 1.32 Vo+1.0 - 2.0 Vo+1.5 - 3.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6 Vo+7.2 - 14.4 Vo+4.8 - 12.0OPERATING INDICATION LED (Green)REMOTE SENSING ProvidedREMOTE ON/OFF Provided

ISOLATION

INPUT-OUTPUT-RC AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-AUX-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-AUX AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)

ENVIRONMENT

OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis

SAFETY ANDNOISEREGULATIONS

AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2

OTHERSCASE SIZE/WEIGHT 120X61X190mm [4.72X2.4X7.48 inches] (without terminal block and screw) (WXHXD) /1.6kg maxCOOLING METHOD Forced cooling (internal fan)

*7

*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).

*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual

in detail.*4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage

protection circuit is please contact us for details.

*5 Derating is required.Consult us for details.*6 Please contact us about safety approvals for the model with option.*7 Please contact us about class C.* A sound may occur from power supply at pulse loading.

PBA600FAC-DC Power Supplies Enclosed Type

PB A 600 F -5 -O

Ordering information

1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *6

C : with Coating G : Low leakage current U : Operation stop voltage

is set at a lower value F1 : With Long-Life fan F3 : Reverse air exhaust

type F4 : Low speed fan

R

1 2 3 4 5 6

High voltage pulse noise type : NAP seriesLow leakage current type : NAM series

Refer to instruction manual 7.1.

Example recommended EMI/EMC filterNAC-16-472

*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.

*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

June 25, 2020

Page 19: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-19

(N)

(L)A

CF

GA

C

M5

LED

CN3

CN1CN2

AC(N)

AC(L)

M4 Input terminal cover 4-M4Mounting Hole(Bottom side)

Output voltageadjustable potentiometer

Outputterminal(+)

Outputterminal(-)

AIR FLOW

8-M4Mounting Hole(Both sides)

Name plate

Name plate

Output terminal cover

¶ Tolerance : ±1 [±0.04]¶ Weight : 1.6kg max¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 1.2N · m(12.8kgf·cm)max¶ Screw tightening torque : M4 1.6N • m(16.9kgf • cm)max

¶ The housing for the remote sensing unused is mounted on CN1¶1 F1(Optional):190.5

61

17

10

(13.8)

[0.54]

[0.71][0.98]

[7.48]

[5.91][0.94]

[0.94] [5.91]

[0.24]

[0.79]

[1.91]

[2.4]

[0.5

5]

[0.4

9][1

.5]

[0.5

5][2

.07]

[3.9

4] [4.7

2]

[0.3

9]

[1.0

8]

[0.6

7]

[0.3

4]

[3.6

4]

[0.3

9][0

.28]

[0.2

4]

(18)

190 6max¶1(F1:190.5)

120

24 150±0.5

24 150±0.5

12.5

38±0

.5

25max

20max

8.7

(6)

7

1414

27.5

(52.

5)

(48.5)

(92.

5)

10

100±0

.5

FG( )

¶ Please connect safety ground to FG terminal on the unit.

M5 2.5N • m(24.5kgf • cm)max

CN

1C

N2

CN

3

Block diagram

250V15A

INRUSHCURRENT

LIMITRECTIFIER

DC OUT

RC(REMOTE ON / OFF)

VB(VOLTAGE BALANCE)

CB(CURRENT BALANCE)

PG(POWER GOOD)

AUX(12V 0.1A)

±M

±S(REMOTE SENSING)

NOISEFILTER

SWITCHINGDEVICE

CONTROL

RECTIFIERAND

FILTER

RECTIFIERAND

FILTER

VOLTAGESENSING

ACTIVE FILTER

VOLTAGESENSING

CURRENTSENSING

INVERTER

CONTROL

ALARMFANINTERNALREGULATOR

CONTROL

MASTERSLAVE

CONTROL

THERMALPROTECTION

CURRENTSENSING

AC IN

FG

FUSE

85 - 264V

OVER VOLTAGEPROTECTION

External view

PBA600F

June 25, 2020

Page 20: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-20

*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).

Ripple and ripple noise is measured on measuring board with capacitor of 22mF within 150mm from the output terminal.

*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual

in detail.

*4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage protection circuit is please contact us for details.

*5 Derating is required.Consult us for details.*6 Please contact us about safety approvals for the model with option.*7 Please contact us about class C.* A sound may occur from power supply at pulse loading.

PBA1000FAC-DC Power Supplies Enclosed Type

PB A 1000 F -5 -O

Ordering information

1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *6

C : with Coating G : Low leakage current U : Operation stop voltage

is set at a lower value F1 : With Long-Life fan F3 : Reverse air exhaust

type F4 : Low speed fan

R

1 2 3 4 5 6

High voltage pulse noise type : NAP seriesLow leakage current type : NAM series

Refer to instruction manual 7.1.

MODEL PBA1000F-3R3 PBA1000F-5 PBA1000F-7R5 PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36 PBA1000F-48MAX OUTPUT WATTAGE[W] 660 1000 1005 1056 1050 1056 1044 1056

DC OUTPUTACIN 100V 3.3V 200A 5V 200A 7.5V 134A 12V 88A 15V 70A 24V 44A 36V 29A 48V 22AACIN 200V*3 3.3V 200A 5V 200A 7.5V 134A 12V 88A 15V 70A 24V 44(51)A 36V 29A 48V 22A

SPECIFICATIONSMODEL PBA1000F-3R3 PBA1000F-5 PBA1000F-7R5 PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36 PBA1000F-48

INPUT

VOLTAGE[V] AC85 - 264 1f or DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *5)

CURRENT[A]ACIN 100V 9typ 13typACIN 200V 5typ 7typ

FREQUENCY[Hz] 50/60 (47 - 63)

EFFICIENCY[%]ACIN 100V 74typ 79typ 80typ 82typ 82typ 84typ 84typ 84typACIN 200V 76typ 81typ 83typ 84typ 84typ 86typ 86typ 86typ

POWER FACTORACIN 100V 0.98typ (Io=100%)ACIN 200V 0.95typ (Io=100%)

INRUSH CURRENT[A]ACIN 100V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)ACIN 200V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)

LEAKAGE CURRENT[mA] 0.5/1.0max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1, DENAN)

OUTPUT

VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48

CURRENT[A]ACIN 100V 200 200 134 88 70 44 29 22ACIN 200V*3 200 200 134 88 70 44(51) 29 22

LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192maxLOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max

RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max 150max-20 - 0C*1 140max 140max 160max 160max 160max 160max 160max 400max

RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 200max 200max-20 - 0C*1 160max 160max 180max 180max 180max 180max 240max 500max

TEMPERATURE REGULATION[mV]0 to +50C 40max 50max 75max 120max 150max 240max 360max 480max-20 to +50C 60max 75max 120max 180max 180max 290max 440max 600max

DRIFT[mV] *2 12max 20max 30max 48max 60max 96max 144max 192maxSTART-UP TIME[ms] 400typ(ACIN 100/200V, Io=100%) *Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms] 20typ (ACIN 100/200V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92

PROTECTIONCIRCUIT ANDOTHERS

OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automaticallyOVERVOLTAGE PROTECTION[V] *4 Vo+0.66 - 1.32 Vo+1.0 - 2.0 Vo+1.5 - 3.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6 Vo+7.2 - 14.4 Vo+4.8 - 12.0OPERATING INDICATION LED (Green)REMOTE SENSING ProvidedREMOTE ON/OFF Provided

ISOLATION

INPUT-OUTPUT-RC AC3,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-AUX-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-AUX AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)

ENVIRONMENT

OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis

SAFETY ANDNOISEREGULATIONS

AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2

OTHERSCASE SIZE/WEIGHT 150X61X240mm [5.91X2.4X9.45 inches] (without terminal block and screw) (WXHXD) /2.2kg maxCOOLING METHOD Forced cooling (internal fan)

*7

Example recommended EMI/EMC filterNAC-20-472

*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.

*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

June 25, 2020

Page 21: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-21

CN1

CN3CN2

AC(N)AC(L)

M4

LED

8-M4Mounting Hole(Both sides)

Name plate

Input terminal cover

Output voltageadjustable potentiometer

Output terminal(+)

Output terminal(-)

¶ Tolerance : ±1 [±0.04]¶ Weight : 2.2kg max¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 1.2N • m(12.8kgf • cm)max¶ Screw tightening torque : 1.6N • m(16.9kgf • cm)max¶ The housing for the remote sensing unused is mounted on CN1

AIR FLOW

2-M42-º9

Name plate

AC(L)

FG

AC

CN

1 H

(N)

CN

3

CN

2

V.A

DJ

Mounting Hole(Bottom side)

4-M4

79

(18)

15.85

10

51.25[2.02]

[0.3

9][0

.51]

[0.3

5][0

.3]

[3.1

1]

[0.9

4][4

.12]

[4.3

3]

[5.9

1][2

.4]

[1.5

][0

.45]

[0.7

9]

[0.1

][0

.71]

[0.9

8]

[0.62] [0.98]

[1.14]

[1.38] [9.45] [0.24]

[6.5]

[1.14][0.51][0.28] [6.5]

61

13

(25)

7

240 6max

150

25max20

(35)

(7.5

)13

9

29 165±0.5

11.5

38±0

.5

104.

75(2

4)

110±0

.5

29 165 ±0.5

2.5

FG( )

¶ Please connect safety ground to FG terminal on the unit.

[0.35]

Block diagram

250V30A

INRUSHCURRENT

LIMITRECTIFIER

DC OUT

RC(REMOTE ON / OFF)

VB(VOLTAGE BALANCE)

CB(CURRENT BALANCE)

PG(POWER GOOD)

AUX(12V 0.1A)

±M

±S(REMOTE SENSING)

NOISEFILTER

SWITCHINGDEVICE

CONTROL

RECTIFIERAND

FILTER

RECTIFIERAND

FILTER

VOLTAGESENSING

ACTIVE FILTER

VOLTAGESENSING

CURRENTSENSING

INVERTER

CONTROL

ALARMFANINTERNALREGULATOR

CONTROL

MASTERSLAVE

CONTROL

THERMALPROTECTION

CURRENTSENSING

AC IN

FG

FUSE

85 - 264V

OVER VOLTAGEPROTECTION

External view

PBA1000F

June 25, 2020

Page 22: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-22

MODEL PBA1500F-3R3 PBA1500F-5 PBA1500F-7R5 PBA1500F-12 PBA1500F-15 PBA1500F-24 PBA1500F-36 PBA1500F-48MAX OUTPUT WATTAGE[W] 990 1500 1500 1500 1500 1680 1692 1680

DC OUTPUTACIN 100V 3.3V 300A 5V 300A 7.5V 200A 12V 125A 15V 100A 24V 65A 36V 42A 48V 32AACIN 200V*3 3.3V 300A 5V 300A 7.5V 200A 12V 125A 15V 100A 24V 70(105)A 36V 47(70)A 48V 35A

SPECIFICATIONSMODEL PBA1500F-3R3 PBA1500F-5 PBA1500F-7R5 PBA1500F-12 PBA1500F-15 PBA1500F-24 PBA1500F-36 PBA1500F-48

INPUT

VOLTAGE[V] AC85 - 264 1f or DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 7. option *5)

CURRENT[A]ACIN 100V 15typ 19typACIN 200V 8typ 10typ

FREQUENCY[Hz] 50/60 (47 - 63)

EFFICIENCY[%]ACIN 100V 72typ 77typ 81typ 81typ 83typ 84typ 84typ 84typACIN 200V 75typ 81typ 83typ 84typ 86typ 87typ 87typ 87typ

POWER FACTORACIN 100V 0.98typ (Io=100%)ACIN 200V 0.95typ (Io=100%)

INRUSH CURRENT[A]ACIN 100V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)ACIN 200V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)

LEAKAGE CURRENT[mA] 0.9/1.5max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1, DENAN)

OUTPUT

VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48

CURRENT[A]ACIN 100V 300 300 200 125 100 65 42 32ACIN 200V*3 300 300 200 125 100 70(105) 47(70) 35

LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192maxLOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max

RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max 150max-20 - 0C*1 140max 140max 160max 160max 160max 160max 160max 400max

RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 200max 200max-20 - 0C*1 160max 160max 180max 180max 180max 180max 240max 500max

TEMPERATURE REGULATION[mV]0 to +50C 40max 50max 75max 120max 150max 240max 360max 480max-20 to +50C 60max 75max 120max 180max 180max 290max 440max 600max

DRIFT[mV] *2 12max 20max 30max 48max 60max 96max 144max 192maxSTART-UP TIME[ms] 600typ(ACIN 100/200V, Io=100%)HOLD-UP TIME[ms] 20typ (ACIN 100/200V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92

PROTECTIONCIRCUIT ANDOTHERS

OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automaticallyOVERVOLTAGE PROTECTION[V] *4 Vo+0.66 - 1.32 Vo+1.0 - 2.0 Vo+1.5 - 3.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6 Vo+7.2 - 14.4 Vo+4.8 - 12.0OPERATING INDICATION LED (Green)REMOTE SENSING ProvidedREMOTE ON/OFF Provided

ISOLATION

INPUT-OUTPUT-RC AC3,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-AUX-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-AUX AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)

ENVIRONMENT

OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis

SAFETY ANDNOISEREGULATIONS

AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B, additional EMI/EMC Filter required for meeting class BHARMONIC ATTENUATOR Complies with IEC61000-3-2

OTHERSCASE SIZE/WEIGHT 178X61X268mm [7.01X2.4X10.55 inches] (without terminal block and screw) (WXHXD) /3.4kg maxCOOLING METHOD Forced cooling (internal fan)

*7

*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).

Ripple and ripple noise is measured on measuring board with capacitor of 22mF within 150mm from the output terminal.

*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual

in detail.

*4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage protection circuit is please contact us for details.

*5 Derating is required.Consult us for details.*6 Please contact us about safety approvals for the model with option.*7 Please contact us about class C.* A sound may occur from power supply at pulse loading.

PBA1500FAC-DC Power Supplies Enclosed Type

PB A 1500 F -5 -O

Ordering information

1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *6

C : with Coating G : Low leakage current U : Operation stop voltage

is set at a lower value F1 : With Long-Life fan F3 : Reverse air exhaust

type F4 : Low speed fan

R

1 2 3 4 5 6

High voltage pulse noise type : NAP seriesLow leakage current type : NAM series

Refer to instruction manual 7.1.

Example recommended EMI/EMC filterNAC-20-472

*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.

*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

June 25, 2020

Page 23: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-23

Name plate

(N)

V.AD

J

FG

NC

AC

(L)A

CC

N1

CN

2

CN

3

CN1

4-M4

2-º9

CN3CN2

NC

AC(N)

AC(L)

¶ Tolerance : ±1 [±0.04]¶ Weight : 3.4kg max¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 1.2N • m(12.8kgf • cm)max¶ Screw tightening torque : 1.6N • m(16.9kgf • cm)max¶ The housing for the remote sensing unused is mounted on CN1

Output voltageadjustable potentiometer

Name plate

AIR FLOW

8-M4

8-M4

Mounting Hole(Both sides)

M4Input terminal cover

Output terminal(+)

Output terminal(-)

LED

107

1013

9(7

.5)15.85

(25)

(18)

1510

4

(24)

132

171.5 ±0.519

152.

4±0

.5

268 6max

178

19 171.5 ±0.5

11.5

38±0

.5

(45)

61

12.8

25max

51.25

FG( )

¶ Please connect safety ground to FG terminal on the unit.

Mounting Hole(Both sides)[0.62]

[2.02]

[0.98]

[0.75] [6.75]

[0.75][0.59][0.39]

[0.35]

[6.75]

[1.77] [0.24][10.55]

[4.2

1]

[5.2

]

[6]

[0.5

]

[7.0

1][2

.4]

[1.5

][0

.45]

[0.9

4]

[0.9

8][0

.71]

[0.1

6]

[0.3

9][0

.51]

[0.3

5][0

.3]

Block diagram

250V30A

INRUSHCURRENT

LIMITRECTIFIER

DC OUT

RC(REMOTE ON / OFF)

VB(VOLTAGE BALANCE)

CB(CURRENT BALANCE)

PG(POWER GOOD)

AUX(12V 0.1A)

±M

±S(REMOTE SENSING)

NOISEFILTER

SWITCHINGDEVICE

CONTROL

RECTIFIERAND

FILTER

RECTIFIERAND

FILTER

VOLTAGESENSING

ACTIVE FILTER

VOLTAGESENSING

CURRENTSENSING

INVERTER

CONTROL

ALARMFANINTERNALREGULATOR

CONTROL

MASTERSLAVE

CONTROL

THERMALPROTECTION

CURRENTSENSING

AC IN

FG

FUSE

85 - 264V

OVER VOLTAGEPROTECTION

External view

PBA1500F

June 25, 2020

Page 24: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-24

MODEL PBA1500T-5 PBA1500T-12 PBA1500T-24 PBA1500T-48MAX OUTPUT WATTAGE[W] 1500 1500 1680 1680DC OUTPUT ACIN 200V*3 5V 300A 12V 125A 24V 70(105)A 48V 35A

SPECIFICATIONSMODEL PBA1500T-5 PBA1500T-12 PBA1500T-24 PBA1500T-48

INPUT

VOLTAGE[V] AC170 - 264 3f (AC100 Please refer to the instruction manual 7. option *5)

CURRENT[A] ACIN 200V 6typ

FREQUENCY[Hz] 50/60 (47 - 63)

EFFICIENCY[%] ACIN 200V 81typ 84typ 87typ 87typ

POWER FACTOR ACIN 200V 0.95typ (Io=100%)

INRUSH CURRENT[A] ACIN 200V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)

LEAKAGE CURRENT[mA] 1.5max (ACIN 240V 60Hz, Io=100%, According to IEC60950-1, DENAN)

OUTPUT

VOLTAGE[V] 5 12 24 48

CURRENT[A] ACIN 200V*3 300 125 70(105) 35

LINE REGULATION[mV] 20max 48max 96max 192max

LOAD REGULATION[mV] 40max 100max 150max 300max

RIPPLE[mVp-p]0 to +50C*1 80max 120max 120max 150max

-20 - 0C*1 140max 160max 160max 400max

RIPPLE NOISE[mVp-p]0 to +50C*1 120max 150max 150max 200max

-20 - 0C*1 160max 180max 180max 500max

TEMPERATURE REGULATION[mV]0 to +50C 50max 120max 240max 480max

-20 to +50C 75max 180max 290max 600max

DRIFT[mV] *2 20max 48max 96max 192max

START-UP TIME[ms] 300typ(ACIN 200V, Io=100%) *Start-up time is 500ms typ for less than 1 minute of applying input again from turning off the input voltage.

HOLD-UP TIME[ms] 20typ (ACIN 200V, Io=100%)

OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 3.96 - 6.00 8.25 - 13.20 16.50 - 26.40 38.40 - 56.00

OUTPUT VOLTAGE SETTING[V] 5.00 - 5.15 12.00 - 12.48 24.00 - 24.96 48.00 - 49.92

PROTECTIONCIRCUIT ANDOTHERS

OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically

OVERVOLTAGE PROTECTION[V] *4 Vo+1.0 - 2.0 Vo+2.4 - 4.8 Vo+4.8 - 9.6 Vo+2.0 - 12.0

OPERATING INDICATION LED (Green)

REMOTE SENSING Provided

REMOTE ON/OFF Provided

ISOLATION

INPUT-OUTPUT-RC AC3,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)

INPUT-FG AC2,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)

OUTPUT-RC-AUX-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)

OUTPUT-RC-AUX AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)

ENVIRONMENT

OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max

STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max

VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis

IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDNOISEREGULATIONS

AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN

CONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B, additional EMI/EMC Filter required for meeting class B

OTHERSCASE SIZE/WEIGHT 178X61X268mm [7.01X2.4X10.55 inches] (without terminal block and screw) (WXHXD) /3.4kg max

COOLING METHOD Forced cooling (internal fan)

*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).

Ripple and ripple noise is measured on measuring board with capacitor of 22mF within 150mm from the output terminal.

*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual

in detail.

*4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage protection circuit is please contact us for details.

*5 Derating is required.Consult us for details.*6 Please contact us about safety approvals for the model with option.* A sound may occur from power supply at pulse loading.

PBA1500TAC-DC Power Supplies Enclosed Type

PB A 1500 T -5 -O

Ordering information

1 Series name2 Single output3 Output wattage4 Triple input phase5 Output voltage6 Optional *6

C : with Coating G : Low leakage current U : Operation stop voltage

is set at a lower value F1 : With Long-Life fan F3 : Reverse air exhaust

type F4 : Low speed fan

R

1 2 3 4 5 6

Refer to instruction manual 7.1.

Example recommended EMI/EMC filterTAC-10-683

*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.

*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

June 25, 2020

Page 25: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-25

Name plate

(L2)

V.AD

J

FG

(L3)A

C(L1)

CN

1

CN

2

CN

3

CN1

4-M4

2-º9

CN3CN2

AC(L3)

AC(L2)

AC(L1)

¶ Tolerance : ±1 [±0.04]¶ Weight : 3.4kg max¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 1.2N • m(12.8kgf • cm)max¶ Screw tightening torque : 1.6N • m(16.9kgf • cm)max¶ The housing for the remote sensing unused is mounted on CN1

Output voltageadjustable potentiometer

Name plate

AIR FLOW

8-M4

8-M4

Mounting Hole(Both sides)

M4Input terminal cover

Output terminal(+)

Output terminal(-)

LED

107

1013

9(7

.5)15.85

(25)

(18)

1510

4(24)

132

171.5 ±0.519

152.

4±0

.5

268 6max

178

19 171.5 ±0.5

11.5

38±0

.5

(45)

61

12.825max

51.25

FG( )

¶ Please connect safety ground to unit in M4 holes.

Mounting Hole(Both sides)[0.62]

[2.02]

[4.2

1]

[0.3

9][0

.51]

[0.3

5][0

.3]

[0.98]

[0.75] [6.75]

[1.77] [0.24][10.55]

[5.2

]

[6]

[0.5

]

[7.0

1]

[0.9

4]

[0.1

6]

[0.75][0.59][0.39]

[0.35]

[6.75]

[2.4

]

[1.5

][0

.45]

[0.9

8][0

.71]

Block diagram

AC250V16A

INRUSHCURRENT

LIMITRECTIFIER

DC OUT

RC(REMOTE ON / OFF)

VB(VOLTAGE BALANCE)

CB(CURRENT BALANCE)

PG(POWER GOOD)

AUX(12V 0.1A)

±M(MONITOR)

±S(REMOTE SENSING)

NOISEFILTER

SWITCHINGDEVICE

CONTROL

RECTIFIERAND

FILTER

RECTIFIERAND

FILTER

VOLTAGESENSING

ACTIVE FILTER

VOLTAGESENSING

CURRENTSENSING

INVERTER

CONTROL

ALARMFAN

OPENPHASE

INTERNALREGULATOR

CONTROL

MASTERSLAVE

CONTROL

THERMALPROTECTION

CURRENTSENSING

AC IN

(3º)

FG

FUSE

170 - 264V

OVER VOLTAGEPROTECTION

External view

PBA1500T

June 25, 2020

Page 26: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-26

MODEL PBW15F-12 PBW15F-15MAX OUTPUT WATTAGE[W] *5 16.8 15.0

DC OUTPUTVOLTAGE[V] *6 t12 ( +24 ) t15 ( +30 )CURRENT1[A] 0.7 0.5CURRENT2[A]*5 1.4 1.0

SPECIFICATIONSMODEL PBW15F-12 PBW15F-15

INPUT

VOLTAGE[V] AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *8)

CURRENT[A]ACIN 100V 0.40typ (CURRENT1)ACIN 200V 0.20typ (CURRENT1)

FREQUENCY[Hz] 50/60 (47 - 440) or DC

EFFICIENCY[%]ACIN 100V 74typ (CURRENT1) 78typ (CURRENT1)ACIN 200V 77typ (CURRENT1) 80typ (CURRENT1)

INRUSH CURRENT[A]ACIN 100V 15typ (CURRENT1) (At cold start)ACIN 200V 30typ (CURRENT1) (At cold start)

LEAKAGE CURRENT[mA] 0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)

OUTPUT

VOLTAGE[V] t12 / ( +24V reference number ) t15 / ( +30V reference number )CURRENT1[A] 0.7 / 0.7 0.5 / 0.5CURRENT2[A] *5 1.4 / - 1.0 / -LINE REGULATION[mV] *9 60max / 96max 60max / 96maxLOAD REGULATION 1[mV] *3 600max / 150max 600max / 150maxLOAD REGULATION 2[mV] *4

*11

*11

*11 750max / - 750max / -

RIPPLE[mVp-p]0 to +50C*1 120max / 240max 120max / 240max-10 - 0C*1 160max / 320max 160max / 320max

RIPPLE NOISE[mVp-p]0 to +50C*1 150max / 300max 150max / 300max-10 - 0C*1 180max / 360max 180max / 360max

TEMPERATURE REGULATION[mV]0 to +50C 120max 150max-10 to +50C 150max 180max

DRIFT[mV] *2 48max 60maxSTART-UP TIME[ms] 200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 9.60 - 13.2 (+V and -V are simultaneously adjusted) 13.2 - 16.5 (+V and -V are simultaneously adjusted)OUTPUT VOLTAGE SETTING[V] 11.5 - 12.5 (+V and -V CURRENT1) 14.4 - 15.6 (+V and -V CURRENT1)

PROTECTIONCIRCUIT ANDOTHERS

OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 16.8 - 24.0 20.0 - 29.0OPERATING INDICATION LED (Green)REMOTE ON/OFF None

ISOLATIONINPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)

ENVIRONMENT

OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis

SAFETY ANDNOISEREGULATIONS

AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2 (Not built-in to active filter *7)

OTHERSCASE SIZE/WEIGHT 31X78X85mm [1.22X3.07X3.35 inches] (without terminal block) (WXHXD) / 200g max (with cover : 235g max)COOLING METHOD Convection

*12

*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).

*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.

*3 Figures for 0 to rated current 1.The current not measured side is fixed.

*4 Figures for 0 to rated current 2.The current not measured

side is fixed.*5 The sum of +power -power must be less than output power.*6 t12,t15 can be used as +24 and +30. *7 When two or more units are used,they may not comply with

the harmonic attenuator. Please contact us for details.*8 Derating is required.*9 Figures to rated current 1.

*10 Please contact us about safety approvals for the model with option.

*11 Please contact us about dynamic load and input response.*12 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.

PBW15FAC-DC Power Supplies Enclosed Type

PB W 15 F -O -O

Ordering information

1 Series name2 Dual output3 Output wattage4 Universal input5 Output voltage6 Optional *10

C : with Coating G : Low leakage current E : Low leakage current

and EMI class A T : Vertical terminal block J1 : VH (J.S.T.) connector type N : with Cover N1 : with DIN rail V : Output voltage setting

potentiometer external-ly

R

1 2 3 4 5 6

High voltage pulse noise type : NAP seriesLow leakage current type : NAM series

Cover is optional

Example recommended EMI/EMC filterNAC-06-472

*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.

*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

June 25, 2020

Page 27: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-27

2.5

Point A:C102

Mounting hole2-M3

Mounting hole2-M3

-V

AC(N)

AC(L)

FG

COM

+V

Cover name plate

Cover (option)

Name plate

M3

Terminal cover

5

18

31 34.5

34.5

78

36.5

85

70.5

12.2±1.5

18

31±0.5

60±0.5

11.5

9.5

7.5

16.5±2

15.1±1.5

22.6±1.5

PBA15FPBW15F

LED

Voltage adjust

¶ Tolerance : ±1 [±0.04]¶ Weight : 200g max (with cover : 235g max)¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.6N • m(6.3kgf • cm)max¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max¶ Please connect safety ground to the unit in 2-M3 holes.

¶ External size of option T,J1,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.

[0.71]

[2.7

8]

[0.3

][0

.37]

[0.4

5]

[1.3

6][0

.71] [1

.22]

[1.3

6]

[3.0

7]

[0.48]

[0.59]

[0.89]

[0.1]

[0.65] [3.35]

[1.22]

[2.36] [0.2]

[1.44]

Block diagram

2.5AAC250V

AC IN

+V

COM DCOUT

-V

FG

85 - 264VNOISEFILTER

INVERTERCONTROL

CURRENTSENSING

RECTIFIERAND

FILTER

RECTIFIERAND

FILTER

CONTROL

Photocoupler

Photocoupler

TRANSFORMER

INRUSHCURRENT

LIMIT

FUSE

OVER VOLTAGEPROTECTION

RECTIFIERAND

FILTER

External view

PBW15F

June 25, 2020

Page 28: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-28

MODEL PBW30F-5 PBW30F-12 PBW30F-15MAX OUTPUT WATTAGE[W] *5 15 31.2 30.0

DC OUTPUTVOLTAGE[V] *6 t5 ( +10 ) t12 ( +24 ) t15 ( +30 )CURRENT1[A] 1.5 1.3 1.0CURRENT2[A]*5 2.0 1.7 1.4

SPECIFICATIONSMODEL PBW30F-5 PBW30F-12 PBW30F-15

INPUT

VOLTAGE[V] AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *8)

CURRENT[A]ACIN 100V 0.4typ (CURRENT1) 0.7typ (CURRENT1)ACIN 200V 0.25typ (CURRENT1) 0.4typ (CURRENT1)

FREQUENCY[Hz] 50/60 (47 - 440) or DC

EFFICIENCY[%]ACIN 100V 75typ (CURRENT1) 77typ (CURRENT1) 78typ (CURRENT1)ACIN 200V 75typ (CURRENT1) 81typ (CURRENT1) 79typ (CURRENT1)

INRUSH CURRENT[A]ACIN 100V 15typ (CURRENT1) (At cold start)ACIN 200V 30typ (CURRENT1) (At cold start)

LEAKAGE CURRENT[mA] 0.30/0.65max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)

OUTPUT

VOLTAGE[V] t5 / ( +10V reference number ) t12 / ( +24V reference number ) t15 / ( +30V reference number )CURRENT1[A] 1.5 / 1.5 1.3 / 1.3 1.0 / 1.0CURRENT2[A] *5 2.0 / - 1.7 / - 1.4 / -LINE REGULATION[mV] 20max / 36max 60max / 96max 60max / 96maxLOAD REGULATION 1[mV] 250max / 100max 600max / 150max 600max / 150maxLOAD REGULATION 2[mV] 500max / - 750max / - 750max / -

RIPPLE[mVp-p]0 to +50C*1 80max / 240max 120max / 240max 120max / 240max-10 - 0C*1 140max / 320max 160max / 320max 160max / 320max

RIPPLE NOISE[mVp-p]0 to +50C*1 120max / 300max 150max / 300max 150max / 300max-10 - 0C*1 160max / 360max 180max / 360max 180max / 360max

TEMPERATURE REGULATION[mV]0 to +50C 50max 120max 150max-10 to +50C 60max 150max 180max

DRIFT[mV] *2 20max 48max 60maxSTART-UP TIME[ms] 200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.99 - 6.00 (+V and -V are simultaneously adjusted) 9.60 - 13.2 (+V and -V are simultaneously adjusted) 13.2 - 16.5 (+V and -V are simultaneously adjusted)OUTPUT VOLTAGE SETTING[V] 4.99 - 5.30 (+V and -V CURRENT1) 11.5 - 12.5 (+V and -V CURRENT1) 14.4 - 15.6 (+V and -V CURRENT1)

PROTECTIONCIRCUIT ANDOTHERS

OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 6.90 - 10.0 16.8 - 24.0 20.0 - 29.0OPERATING INDICATION LED (Green)REMOTE ON/OFF None

ISOLATIONINPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)

ENVIRONMENT

OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis

SAFETY ANDNOISEREGULATIONS

AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2 (Not built-in to active filter *7)

OTHERSCASE SIZE/WEIGHT 31X78X103mm [1.22X3.07X4.06 inches] (without terminal block) (WXHXD) / 270g max (with cover : 310g max)COOLING METHOD Convection

*9

*3

*4

*11

*11

*11

*12

*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).

*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.

*3 Figures for 0 to rated current 1.The current not measured side is fixed.

*4 Figures for 0 to rated current 2.The current not measured

side is fixed.*5 The sum of +power -power must be less than output power.*6 t5,t12,t15 can be used as +10,+24 and +30. *7 When two or more units are used,they may not comply with

the harmonic attenuator. Please contact us for details.*8 Derating is required.*9 Figures to rated current 1.

*10 Please contact us about safety approvals for the model with option.

*11 Please contact us about dynamic load and input response.*12 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.

PBW30FAC-DC Power Supplies Enclosed Type

PB W 30 F -O -O

Ordering information

1 Series name2 Dual output3 Output wattage4 Universal input5 Output voltage6 Optional *10

C : with Coating G : Low leakage current E : Low leakage current

and EMI class A T : Vertical terminal block J1 : VH (J.S.T.) connector type N : with Cover N1 : with DIN rail V : Output voltage setting

potentiometer external-ly

R

1 2 3 4 5 6

High voltage pulse noise type : NAP seriesLow leakage current type : NAM series

Cover is optional

Example recommended EMI/EMC filterNAC-06-472

*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.

*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

June 25, 2020

Page 29: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-29

2.5

Mounting hole2-M3

Mounting hole2-M3

Point A:C102

Name plate

Cover name plate

Cover (option)

M3

Terminal cover

-V

AC(N)

AC(L)

FG

COM

+V

18

12.2±1.5

70.5

1836

.5

46±0.5 40.5

75±0.5 8.5

15.1±1.5

22.6±1.5

11.5

9.5

7.5

16.5±2

31

103

78

34.5

PBW30FPBA30F

¶ Tolerance : ±1 [±0.04]¶ Weight : 270g max (with cover : 310g max)¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.6N • m(6.3kgf • cm)max¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max¶ Please connect safety ground to the unit in 2-M3 holes.

¶ External size of option T,J1,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.

LED

Voltage adjust[0.71]

[2.7

8]

[0.48]

[0.59]

[0.89]

[0.1]

[0.3

][0

.37]

[0.4

5]

[1.4

4]

[3.0

7]

[0.65] [4.06]

[1.81] [1.59]

[0.7

1] [1.2

2]

[1.3

6]

[2.95] [0.33]

Block diagram

3.15AAC250V

NOISEFILTER

AC IN

+V

COM DCOUT

-V

FG

85 - 264VNOISEFILTER

INVERTERCONTROL

CURRENTSENSING

RECTIFIERAND

FILTER

RECTIFIERAND

FILTER

CONTROL

Photocoupler

Photocoupler

TRANSFORMER

INRUSHCURRENT

LIMIT

FUSE

OVER VOLTAGEPROTECTION

RECTIFIERAND

FILTER

External view

PBW30F

June 25, 2020

Page 30: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-30

MODEL PBW50F-5 PBW50F-12 PBW50F-15MAX OUTPUT WATTAGE[W] *6 30 50.4 51

DC OUTPUTVOLTAGE[V] *8 t5 ( +10 ) t12 ( +24 ) t15 ( +30 )CURRENT1[A] 3.0 2.1 1.7CURRENT2[A]*6 4.0 2.7 2.4

SPECIFICATIONSMODEL PBW50F-5 PBW50F-12 PBW50F-15

INPUT

VOLTAGE[V] AC85 - 264 1f or DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *3)

CURRENT[A]ACIN 100V 0.45typ (CURRENT1) 0.70typ (CURRENT1)ACIN 200V 0.30typ (CURRENT1) 0.40typ (CURRENT1)

FREQUENCY[Hz] 50/60 (47 - 63)

EFFICIENCY[%]ACIN 100V 76typ (CURRENT1) 81typ (CURRENT1) 81typ (CURRENT1)ACIN 200V 77typ (CURRENT1) 83typ (CURRENT1) 83typ (CURRENT1)

POWER FACTOR(Io=100%) ACIN 100V 0.98typ 0.99typACIN 200V 0.87typ 0.93typ

INRUSH CURRENT[A]ACIN 100V 15typ (CURRENT1) (At cold start)ACIN 200V 30typ (CURRENT1) (At cold start)

LEAKAGE CURRENT[mA] 0.40/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)

OUTPUT

VOLTAGE[V] t5 / ( +10V reference number ) t12 / ( +24V reference number ) t15 / ( +30V reference number )CURRENT1[A] 3.0 / 3.0 2.1 / 2.1 1.7 / 1.7CURRENT2[A] *6 4.0 / - 2.7 / - 2.4 / -LINE REGULATION[mV] 20max / 36max 48max / 96max 60max / 96maxLOAD REGULATION 1[mV] *4 250max / 100max 600max / 150max 600max / 150maxLOAD REGULATION 2[mV] *5 500max / - 750max / - 750max / -

RIPPLE[mVp-p]0 to +50C*1 80max / 240max 120max / 240max 120max / 240max-10 - 0C*1 140max / 320max 160max / 320max 160max / 320max

RIPPLE NOISE[mVp-p]0 to +50C*1 120max / 300max 150max / 300max 150max / 300max-10 - 0C*1 160max / 360max 180max / 360max 180max / 360max

TEMPERATURE REGULATION[mV]0 to +50C 50max 120max 150max-10 to +50C 60max 150max 180max

DRIFT[mV] *2 20max 48max 60maxSTART-UP TIME[ms] 350typ(ACIN 100V, Io=100%)HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.99 - 6.00 (+V and -V are simultaneously adjusted) 9.60 - 13.2 (+V and -V are simultaneously adjusted) 13.2 - 16.5 (+V and -V are simultaneously adjusted)OUTPUT VOLTAGE SETTING[V] 4.99 - 5.30 (+V and -V CURRENT1) 11.5 - 12.5 (+V and -V CURRENT1) 14.4 - 15.6 (+V and -V CURRENT1)

PROTECTIONCIRCUIT ANDOTHERS

OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 6.90 - 10.0 16.8 - 24.0 20.0 - 29.0OPERATING INDICATION LED (Green)REMOTE ON/OFF Optional (Required external power source)

ISOLATIONINPUT-OUTPUT-RC *7 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)OUTPUT-RC-FG *7 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)

ENVIRONMENT

OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis

SAFETY ANDNOISEREGULATIONS

AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2

OTHERSCASE SIZE/WEIGHT 31X82X120mm [1.22X3.23X4.72 inches] (without terminal block) (WXHXD) / 280g max (with cover : 325g max)COOLING METHOD Convection

*10

PBW50FAC-DC Power Supplies Enclosed Type

PB W 50 F -O -O

Ordering information

1 Series name2 Dual output3 Output wattage4 Universal input5 Output voltage6 Optional *9

C : with Coating G : Low leakage current (0.15mA max / ACIN 240V) E : Low leakage current

and EMI class A (0.5mA max / ACIN 240V) T : Vertical terminal block J1 : VH (J.S.T.) connector type R : with Remote ON/OFF N : with Cover N1 : with DIN rail V : Output voltage setting

potentiometer external-ly

R

1 2 3 4 5 6

High voltage pulse noise type : NAP seriesLow leakage current type : NAM series

*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).

*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.

*3 Derating is required.*4 Figures for 0 to rated current 1.The current not measured

side is fixed.

*5 Figures for 0 to rated current 2.The current not measured side is fixed.

*6 The sum of +power -power must be less than output power.*7 RC is applied to remote ON/OFF option. RC is isolated with

input/output and FG.*8 t5,t12,t15 can be used as +10,+24 and +30.

*9 Please contact us about safety approvals for the model with option.

*10 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.

Cover is optional

Example recommended EMI/EMC filterNAC-06-472

*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.

*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

June 25, 2020

Page 31: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-31

¶ Tolerance : ±1 [±0.04]¶ Weight : 280g max (with cover : 325g max)¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.49N • m(5kgf • cm)max¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max¶ Please connect safety ground to the unit in 2-M3 holes.

¶ External size of option T,J1,R,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.

LEDVoltage adjust

PBW50F

-V

CN3Connector for Remote ON/OFF (option)

21

Cover name plate

Cover (option)

A

Name plate

M3

Mounting hole2-M3

Mounting hole2-M3

AC(N)

AC(L)

FG

COM

+V

Terminal cover

Point A

(16.5)

9.5

(12)

(20)

(11)

(71)

(21.5)

(14)

82

34.5

35

120

477±0.5

7.5

88 ±0.5 11

18

310.

5

Pin No. Contents12

RC(+)RC(- )

CN3 Option (Mfr : J.S.T.)

Connector type

Model B2B-XH-AMating Connector (Terminal)XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6

Barrier strip type

[0.79]

[0.65] [4.72]

[3.03] [0.16]

[0.43][3.46]

[0.43]

[2.8

]

[0.3

][0

.37]

[0.4

7]

[1.3

8]

[3.2

3]

[0.7

1] [1.2

2]

[1.3

6]

[0.0

2]

[0.55]

[0.85]

( )

Block diagram

FG

CONTROL

TRANSFORMER

CONTROL

+DC OUT

NOISEFILTER

-DC OUT

INVERTER

AC IN 85 - 264V

FUSE

RECTIFIER

BOOSTERINDUCTOR

INVERTER

CONTROL

RC

EXTERNALSOURCE

E

OPTION

250V2A

RECTIFIERAND

FILTER

RECTIFIERAND

FILTER

INRUSHCURRENT

LIMIT

RECTIFIERAND

FILTER

OVER VOLTAGEPROTECTION

CURRENTSENSING

CURRENTSENSING

External view

PBW50F

June 25, 2020

Page 32: Power World wide Safety EMI Inrush OCP OVP Factor

*The following information covers PBA300F - 1500F. Please see External View for PBA10F - 150F and PBW15F - 50F.

*PBA300F - 1500F *PBA1500T

¿ PBA1000F

¿ PBA600F

¿ PBA1500F

¿ PBA300F

( N)( L)AC

FGAC

CN1CN2CN3

1 2

7 89å 0

4 5 6

1AC (L) Input Terminals AC85 - 264V f47 - 63Hz2AC (N) (M4)3NC4Frame ground (M4 )5-Output6+Output7LED8Output voltage adjustable potentiometer9CN10CN2 ConnectorsåCN3*Please see Optional Parts for dedicated harnesses.

1 2

7 89

4 5 6

å 0

HV. ADJ

1 2 5 6

789å 0

4

AC(L) FG

ACCN1

H

(N)

CN3

CN2

V. ADJ

1 2 3 5 6

789å 0

4

( N)

V. ADJ

FGNCAC

( L)AC

CN1

CN2

CN3

¿ PBA1500T

1AC (L1) 2AC (L2)3AC (L3)4Frame ground (M4 )5-Output6+Output7LED8Output voltage adjustable potentiometer9CN10CN2 ConnectorsåCN3

1 2 3 5 6

789å 0

4

(L2)

V.ADJ

FG(L3)AC

(L1)

CN1

CN2

CN3

PBA/PBW-32

Terminal Blocks

PBA∙PBW-series

June 25, 2020

Page 33: Power World wide Safety EMI Inrush OCP OVP Factor

Installation Method¡Do not insert a screw more than 6mm from the outside of a power

supply to keep enough insulation distance between the screw and internal components.

¿ PBA10F, PBA15F, PBW15F, PBA30F, PBW30F, PBA50F, PBW50F, PBA75F, PBA100F and PBA150F

¡If you use two or more power supplies side by side, please keep a sufficient distance between them to allow enough air ventilation.

¡Ambient temperature around each power supply should not ex-ceed the temperature range shown in ‟derating”.

¿ PBA300F, PBA600F, PBA1000F, PBA1500F and PBA1500T¡The power supplies have a built-in forced cooling fan. Do not block ventilation at the suction side (terminal block side) and its opposite

side (fan installation side). If you need to secure a power supply by screws, securely fix it, taking into consideration of its weight. You can install it in any direction.

¡If you use a power supply in a dusty environment, it can give a cause for a failure. Please consider taking such countermeasures as in-stalling an air filter near the suction area of the system to prevent a failure.

¡In PBA300F, PBA1500F and PBA1500T, ventilation holes are located on the mounting side. If you would like to install the unit by using that side, please contact us for details.

PCB

2

1CN3 CN2 CN1

10

9

2

1

10

9

2

1

8

7

1

91

91

7

2

CN1

PCB

CN2

CN3

102

102

8

¿ PBA300F, 600F Pin Configuration

¿ PBA1000F, 1500F Pin Configuration

Pin Configuration and Functions of CN1 and CN2Pin No. Function

1 +M : Self sensing terminal. (Do not wire for external connection.)2 +S : +Sensing3 -M : Self sensing terminal. (Do not wire for external connection.)4 -S : -Sensing5 VB : Voltage balance6 CB : Current balance7 TRM : Adjustment of output voltage8 -S : -Sensing9 RC2 : Remote ON/OFF

10 RCG : Remote ON/OFF (GND)

Pin Configuration and Functions of CN3Pin No. Function

1 -S : -Sensing2 -S : -Sensing3 AUX : Auxiliary output (12V 0.1A)4 RC1 : Remote ON/OFF5 AUXG : Auxiliary output (GND)6 N.C. : No connection7 PG : Alarm8 PGG : Alarm (GND)

* Common signs among CN1, CN2 and CN3 such as -S represent the same potential.

Matching connecters and terminals on CN1, CN2 and CN3Connector Housing Terminal Mfr.

CN1S10B-PHDSS PHDR-10VS Reel : SPHD-002T-P0.5

Loose : BPHD-001T-P0.5J.S.T.CN2

CN3 S8B-PHDSS PHDR-08VS

6mm max

Chassis of PBA series

Chassis of customer system

Mounting Screw

CBA

Normal mounting

PBA/PBW-33

Terminal Blocks

Assembling and Installation Method

PBA∙PBW-series

June 25, 2020

Page 34: Power World wide Safety EMI Inrush OCP OVP Factor

¿ PBA10F, PBA15F, PBW15F, PBA30F, PBW30F Input voltage Derating Curve

¿ PBA10F, PBA15F, PBW15F, PBA30F, PBW30F, PBA50F, PBW50F, PBA75F, PBA100F, PBA150F Ambient temperature derating curve

¿ PBA300F, PBA600F, PBA1000F, PBA1500F, PBA1500T Ambient temperature derating curve

¡In the hatched area, the specification of Ripple, Ripple Noise is different from other area.¡ The ambient temperature should be measured 5 to 10 cm away from the power supply so that it won’t be influenced by the heat from the

power supply. Please consult us for more details.¡Make sure the temperature at point A is less than the temperatures shown in Instruction Manual 4.

¡In the hatched area, the specification of Ripple, Ripple Noise is different from other area.¡Derating curve depending on an ambient temperature (temperature of air sucked in for a cooling purpose) is shown above.

¿ PBA1500F Input voltage Derating Curve

Ambient temperature[C]

Load

fact

or

[%]

80

70

80

90

100

30

40

50

60

70

71C

010

20

30 40 50 60- 20 - 10 200 10

[AC V]

[%]100

80

85 90

Load

[AC V]

[%]100

80

85 95

Load

at AC100V

-10

706050403020

706050403020807060504030 [20] [30] [40] [50] [60] [70]

[10] [20] [30] [40] [50] [60][10] [20] [30] [40] [50] [60]

2

1

2Forced air (0.5m3 / min)1Convection

80

100

60

40

20

020100

Load

fact

or[%

]

ABC

Ambient temperature [C] Inside [ ]is with case cover

PBA/PBW-34

Derating

PBA∙PBW-series

June 25, 2020

Page 35: Power World wide Safety EMI Inrush OCP OVP Factor

PBA/PBW-35

◆ It is neccessary to read the “Instruction Manual” and “Before using our product” before you use our product.

Instruction Manual https://en.cosel.co.jp/product/powersupply/PBA/ Instruction Manual https://en.cosel.co.jp/product/powersupply/PBW/ Before using our product https://en.cosel.co.jp/technical/caution/index.html

Instruction Manual

NOTICEPBWPBA

*1 Refer to Series/Parallel Operation of Instruction Manual.* The value of input current is at ACIN 100V and rated load, ACIN 200V 3f and rated load in PBA1500T.

input fuseRated

Model frequencySwitching

Circuit method[A]

currentInput operation availability

Series/Parallel

Paralleloperation

PCB/PatternInrush

protectioncircuit

current

Material Doublesidedsided

Single Seriesoperation[kHz]

SCR FR-4

Yes

Thermistor

CEM-3

SCR FR-4

Yes

Yes

SCR

SCR

FR-4

FR-4

Thermistor

Thermistor

Thermistor

CEM-3

CEM-3

CEM-3

*1

*1

*1

*1

100

130

100

100

130

60 - 550

100

100

200

60 - 550

130

130

280

330

230

330

120

60 - 550

60 - 550

120

120

60 - 550

130

0.7

0.7

0.4

19

13

8.2

4.1

2.0

1.3

1.0

0.7

0.7

0.3

0.4

Thermistor

Thermistor

Thermistor

Thermistor

Thermistor

CEM-3

CEM-3

CEM-3

CEM-3

CEM-3

CEM-3

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes Yes

Yes

Yes

Yes

Yes

Yes

Yes

*1

1*

1*

1*

1*

Yes

PBA50F

PBW50F

PBW30F

PBA300F

PBA1000F

PBA1500F

PBW15F

PBA600F

PBA100F

PBA150F

PBA75F

PBA10F

PBA15F

PBA30F

LF

Basic Characteristics Data

250V 4A

250V 2A

250V 30A

250V 15A

250V 10A

250V 3.15A

250V 2A

Yes

Yes

1*

Active filter

Forward converter

Active filter

Forward converter

Active filter

Forward converter

Active filter

Forward converter

Active filter

Forward converter

Active filter

Forward converter

Active filter

Forward converter

Active filter

Forward converter

SCR FR-4130

2006 Yes YesPBA1500T 250V 16A Yes

Active filter

Forward converter

Forward converter

Active filter

Flyback converter

Flyback converter

Flyback converter

Flyback converter

Flyback converter

250V 2.5A

250V 3.15A

250V 2.5A

250V 3.15A

Basic Characteristics Data

PBA∙PBW-series

June 25, 2020