power world wide safety emi inrush ocp ovp factor
TRANSCRIPT
PBA/PBW-1
Feature Small-size & light weight Harmonic attenuator (Complies with IEC61000-3-2) : except PBA1500T Universal input (AC85 - 264V) : PBA1500T(AC170 - 264V 3f) Efficiency increased with synchronous rectification technology (PBA50F - 150F) Variety of option (PBA10F - 150F, PBW15F - 50F) Parallel operation and Parallel redandancy operation (PBA300F - 1500F, PBA1500T) Fan alarm, Remote ON/OFF and other functions (PBA300F - 1500F, PBA1500T)
Safety agency approvals UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 UL508 (PBA10F - 150F, -24, with cover) Complies with DEN-AN
EMI Complies with FCC-B, CISPR22-B, EN55011-B, EN55022-B,
VCCI-B
5-year warranty (refer to Instruction Manual)
CE marking Low Voltage Directive RoHS Directive
EMS Compliance : EN61204-3, EN61000-6-2
EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11
AC-DC Power Supplies Enclosed Type
PowerFactorCorrection
World wide SafetyApprovals
EMI Inrushcurrentlimiting
OCP OVP RemoteON/OFF
ParallelOperation
PBA, PBW-series
June 25, 2020
PBA/PBW-2
MODEL PBA10F-5 PBA10F-12 PBA10F-24MAX OUTPUT WATTAGE[W] 10 10.8 12DC OUTPUT 5V 2A 12V 0.9A 24V 0.5A
SPECIFICATIONSMODEL PBA10F-5 PBA10F-12 PBA10F-24
INPUT
VOLTAGE[V] AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *3)
CURRENT[A]ACIN 100V 0.30typ (Io=100%)
ACIN 200V 0.20typ (Io=100%)
FREQUENCY[Hz] 50/60 (47 - 440) or DC
EFFICIENCY[%]ACIN 100V 74typ 76typ 77typACIN 200V 74typ 76typ 77typ
INRUSH CURRENT[A]ACIN 100V 15typ (Io=100%)
ACIN 200V 30typ (Io=100%)
LEAKAGE CURRENT[mA] 0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 5 12 24CURRENT[A] 2 0.9 0.5LINE REGULATION[mV] 20max 48max 96maxLOAD REGULATION[mV] 40max 100max 150max
RIPPLE[mVp-p]0 to +50C*1 80max 120max 120max-10 - 0C*1
*6
*6
140max 160max 160max
RIPPLE NOISE[mVp-p]0 to +50C*1 120max 150max 150max-10 - 0C*1 160max 180max 180max
TEMPERATURE REGULATION[mV]0 to +50C 50max 120max 240max-10 to +50C 60max 150max 290max
DRIFT[mV] *2 20max 48max 96maxSTART-UP TIME[ms] 200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 - 5.50 10.0 - 13.2 19.2 - 27.0OUTPUT VOLTAGE SETTING[V] 5.00 - 5.15 12.00 - 12.48 24.00 - 24.96
PROTECTIONCIRCUIT ANDOTHERS
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 5.75 - 7.00 15.0 - 18.0 30.0 - 37.0OPERATING INDICATION LED (Green)
REMOTE ON/OFF None
ISOLATIONINPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY ANDNOISEREGULATIONS
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2 (Not built-in to active filter *4)
OTHERSCASE SIZE/WEIGHT 31X78X68mm [1.22X3.07X2.68 inches] (without terminal block) (WXHXD) / 150g max (with cover : 180g max)
COOLING METHOD Convection
*7
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 Derating is required.*4 When two or more units are used,they may not comply with the harmonic attenuator. Please
contact us for details.
*5 Please contact us about safety approvals for the model with option.*6 Please contact us about dynamic load and input response.*7 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.
PBA10FAC-DC Power Supplies Enclosed Type
PB A 10 F -O -O
Ordering information
1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5
C : with Coating G : Low leakage current E : Low leakage current
and EMI class A T : Vertical terminal block J1 : VH (J.S.T.) connector type N : with Cover (UL508 is acquired) N1 : with DIN rail and Cover V : Output voltage setting
potentiometer external-ly
R
1 2 3 4 5 6
High voltage pulse noise type : NAP seriesLow leakage current type : NAM series
Cover is optional
Example recommended EMI/EMC filterNAC-06-472
*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
June 25, 2020
PBA/PBW-3
2.5
Cover name plate
Cover (option)
Name plate
M3
Mounting hole2-M3
Mounting hole2-M3
AC(N)
AC(L)
FG
-V
+V
Terminal coverPoint A:C102
68
34.5
78
15.1±1.5
7.5
9.5
49.5±0.5
36±0.5
16.5±2
31
18
11
34.5
4
22.6±1.5
11.5
18[0.71]
[0.65] [2.68]
[1.95]
[1.42] [0.43]
[0.16][0.59]
[0.89]
[0.1]
[0.48]12.2±1.5
70.5
[2.7
8]
[0.3
][0
.37]
[1.3
6]
[1.3
6]
[1.2
2]
[0.7
1]
[3.0
7]
[0.4
5]
PBA10F
LEDVoltage adjust
¶ Tolerance : ±1 [±0.04]¶ Weight : 150g max (with cover : 180g max)¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.6N • m(6.3kgf • cm)max¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max¶ Please connect safety ground to the unit in 2-M3 holes.
¶ External size of option T,J1,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
Block diagram
2.5AAC250V
NOISEFILTER
INVERTERCONTROL
CURRENTSENSING
RECTIFIERAND
FILTER
CONTROL
AC IN
DC OUT
FG
Photocoupler
Photocoupler
TRANSFORMER
85 - 264V
INRUSHCURRENT
LIMIT
FUSE
OVER VOLTAGEPROTECTION
RECTIFIERAND
FILTER
External view
PBA10F
June 25, 2020
PBA/PBW-4
MODEL PBA15F-3R3 PBA15F-5 PBA15F-9 PBA15F-12 PBA15F-15 PBA15F-24 PBA15F-48MAX OUTPUT WATTAGE[W] 9.9 15 15.3 15.6 15 16.8 16.8DC OUTPUT 3.3V 3A 5V 3A 9V 1.7A 12V 1.3A 15V 1A 24V 0.7A 48V 0.35A
SPECIFICATIONSMODEL PBA15F-3R3 PBA15F-5 PBA15F-9 PBA15F-12 PBA15F-15 PBA15F-24 PBA15F-48
INPUT
VOLTAGE[V] AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *3)
CURRENT[A]ACIN 100V 0.30typ (Io=100%) 0.4typ (Io=100%)
ACIN 200V 0.15typ (Io=100%) 0.2typ (Io=100%)
FREQUENCY[Hz] 50/60 (47 - 440) or DC
EFFICIENCY[%]ACIN 100V 68typ 74typ 75typ 75typ 77typ 75typ 75typACIN 200V 68typ 75typ 77typ 78typ 80typ 78typ 78typ
INRUSH CURRENT[A]ACIN 100V 15typ (Io=100%) (At cold start)
ACIN 200V 30typ (Io=100%) (At cold start)
LEAKAGE CURRENT[mA] 0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 5 9 12 15 24 48CURRENT[A] 3 3 1.7 1.3 1 0.7 0.35LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 192maxLOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max
RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max-10 - 0C*1
*6
*6
140max 140max 160max 160max 160max 160max 200max
RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 250max-10 - 0C*1 160max 160max 180max 180max 180max 180max 300max
TEMPERATURE REGULATION[mV]0 to +50C 50max 50max 90max 120max 150max 240max 480max-10 to +50C 60max 60max 120max 150max 180max 290max 600max
DRIFT[mV] *2 20max 20max 36max 48max 60max 96max 192maxSTART-UP TIME[ms] 200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.60 4.50 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 39.0 - 53.0OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 9.00 - 9.36 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 48.00 - 49.92
PROTECTIONCIRCUIT ANDOTHERS
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 4.00 - 5.25 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 58.0 - 65.0OPERATING INDICATION LED (Green)
REMOTE ON/OFF None
ISOLATIONINPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY ANDNOISEREGULATIONS
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2 (Not built-in to active filter *4)
OTHERSCASE SIZE/WEIGHT 31X78X85mm [1.22X3.07X3.35 inches] (without terminal block) (WXHXD) / 200g max (with cover : 235g max)
COOLING METHOD Convection
*7
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 Derating is required.*4 When two or more units are used,they may not comply with the harmonic attenuator. Please
contact us for details.
*5 Please contact us about safety approvals for the model with option.*6 Please contact us about dynamic load and input response.*7 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.
PBA15FAC-DC Power Supplies Enclosed Type
PB A 15 F -O -O
Ordering information
1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5
C : with Coating G : Low leakage current E : Low leakage current
and EMI class A T : Vertical terminal block J1 : VH (J.S.T.) connector type N : with Cover (UL508 is acquired [5V, 12V, 24V]) N1 : with DIN rail and Cover V : Output voltage setting
potentiometer external-ly
R
1 2 3 4 5 6
High voltage pulse noise type : NAP seriesLow leakage current type : NAM series
Cover is optional
Example recommended EMI/EMC filterNAC-06-472
*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
June 25, 2020
PBA/PBW-5
2.5
Point A:C102
Cover (option)
Name plate
M3
Mounting hole2-M3
Mounting hole2-M3
AC(N)
AC(L)
FG
-V
+V
Terminal cover15.1±1.5
5
18
31
34.5
34.5
78
36.5
11.5
8516.5±2
70.5
12.2±1.5
18
22.6±1.5
31±0.5
60±0.5
9.5
7.5
PBA15FPBW15F
LEDVoltage adjust
Cover name plate
¶ Tolerance : ±1 [±0.04]¶ Weight : 200g max (with cover : 235g max)¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.6N • m(6.3kgf • cm)max¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max¶ Please connect safety ground to the unit in 2-M3 holes.
¶ External size of option T,J1,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
[0.71]
[0.65] [3.35]
[1.22]
[2.36] [0.2]
[1.44][0.59]
[0.89]
[0.1]
[0.48]
[2.7
8]
[0.3
][0
.37]
[1.3
6]
[1.3
6]
[1.2
2]
[0.7
1]
[3.0
7]
[0.4
5]
Block diagram
2.5AAC250V
AC IN
DC OUT
FG
85 - 264VNOISEFILTER
INVERTERCONTROL
CURRENTSENSING
RECTIFIERAND
FILTER
CONTROL
Photocoupler
Photocoupler
TRANSFORMER
INRUSHCURRENT
LIMIT
FUSE
OVER VOLTAGEPROTECTION
RECTIFIERAND
FILTER
External view
PBA15F
June 25, 2020
PBA/PBW-6
MODEL PBA30F-3R3 PBA30F-5 PBA30F-9 PBA30F-12 PBA30F-15 PBA30F-24 PBA30F-48MAX OUTPUT WATTAGE[W] 19.8 30 30.6 30 30 31.2 31.2DC OUTPUT 3.3V 6A 5V 6A 9V 3.4A 12V 2.5A 15V 2A 24V 1.3A 48V 0.65A
SPECIFICATIONSMODEL PBA30F-3R3 PBA30F-5 PBA30F-9 PBA30F-12 PBA30F-15 PBA30F-24 PBA30F-48
INPUT
VOLTAGE[V] AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *3)
CURRENT[A]ACIN 100V 0.50typ (Io=100%) 0.70typ (Io=100%)
ACIN 200V 0.30typ (Io=100%) 0.40typ (Io=100%)
FREQUENCY[Hz] 50/60 (47 - 440) or DC
EFFICIENCY[%]ACIN 100V 68typ 74typ 75typ 76typ 78typ 78typ 79typACIN 200V 69typ 77typ 77typ 78typ 81typ 81typ 81typ
INRUSH CURRENT[A]ACIN 100V 15typ (Io=100%) (At cold start)
ACIN 200V 30typ (Io=100%) (At cold start)
LEAKAGE CURRENT[mA] 0.30/0.65max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 5 9 12 15 24 48CURRENT[A] 6 6 3.4 2.5 2 1.3 0.65LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 192maxLOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max
RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max-10 - 0C*1
*6
*6
140max 140max 160max 160max 160max 160max 200max
RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 250max-10 - 0C*1 160max 160max 180max 180max 180max 180max 300max
TEMPERATURE REGULATION[mV]0 to +50C 50max 50max 90max 120max 150max 240max 480max-10 to +50C 60max 60max 120max 150max 180max 290max 600max
DRIFT[mV] *2 20max 20max 36max 48max 60max 96max 192maxSTART-UP TIME[ms] 200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.60 4.50 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 39.0 - 53.0OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 9.00 - 9.36 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 48.00 - 49.92
PROTECTIONCIRCUIT ANDOTHERS
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 4.00 - 5.25 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 58.0 - 65.0OPERATING INDICATION LED (Green)
REMOTE ON/OFF None
ISOLATIONINPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY ANDNOISEREGULATIONS
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2 (Not built-in to active filter *4)
OTHERSCASE SIZE/WEIGHT 31X78X103mm [1.22X3.07X4.06 inches] (without terminal block) (WXHXD) / 270g max (with cover : 310g max)
COOLING METHOD Convection
*7
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 Derating is required.*4 When two or more units are used,they may not comply with the harmonic attenuator. Please
contact us for details.
*5 Please contact us about safety approvals for the model with option.*6 Please contact us about dynamic load and input response.*7 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.
PBA30FAC-DC Power Supplies Enclosed Type
PB A 30 F -O -O
Ordering information
1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5
C : with Coating G : Low leakage current E : Low leakage current
and EMI class A T : Vertical terminal block J1 : VH (J.S.T.) connector type N : with Cover (UL508 is acquired [5V, 12V, 24V]) N1 : with DIN rail and Cover V : Output voltage setting
potentiometer external-ly
R
1 2 3 4 5 6
High voltage pulse noise type : NAP seriesLow leakage current type : NAM series
Cover is optional
Example recommended EMI/EMC filterNAC-06-472
*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
June 25, 2020
PBA/PBW-7
2.5
Terminal cover
+V
-V
FG
AC(L)
AC(N)
M3
Name plate
Cover (option)
Cover name plate
Point A:C102
2-M3Mounting hole
2-M3Mounting hole
15.1±1.5
22.6±1.5
8.575±0.5
40.546±0.5
36.5
16.5±2
11.5
9.5
7.5
18
70.5
12.2±1.5
18
78
103
31
34.5
PBA30FPBW30F
¶ Tolerance : ±1 [±0.04]¶ Weight : 270g max (with cover : 310g max)¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.6N • m(6.3kgf • cm)max¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max¶ Please connect safety ground to the unit in 2-M3 holes.
¶ External size of option T,J1,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
LEDVoltage adjust [0.71]
[0.65] [4.06]
[1.81]
[2.95] [0.33]
[1.59][0.59]
[0.89]
[0.1]
[0.48]
[2.7
8]
[0.3
][0
.37]
[1.4
4]
[1.3
6]
[1.2
2]
[0.7
1]
[3.0
7]
[0.4
5]
Block diagram
3.15AAC250V
AC IN
DC OUT
FG
85 - 264VNOISEFILTER
INVERTERCONTROL
CURRENTSENSING
RECTIFIERAND
FILTER
RECTIFIERAND
FILTER
CONTROL
Photocoupler
Photocoupler
TRANSFORMER
INRUSHCURRENT
LIMIT
FUSE
OVER VOLTAGEPROTECTION
External view
PBA30F
June 25, 2020
PBA/PBW-8
MODEL PBA50F-3R3 PBA50F-5 PBA50F-9 PBA50F-12 PBA50F-15 PBA50F-24 PBA50F-36 PBA50F-48MAX OUTPUT WATTAGE[W] 33 50 50.4 51.6 52.5 52.8 50.4 52.8DC OUTPUT 3.3V 10A 5V 10A 9V 5.6A 12V 4.3A 15V 3.5A 24V 2.2A 36V 1.4A 48V 1.1A
SPECIFICATIONSMODEL PBA50F-3R3 PBA50F-5 PBA50F-9 PBA50F-12 PBA50F-15 PBA50F-24 PBA50F-36 PBA50F-48
INPUT
VOLTAGE[V] AC85 - 264 1f or DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *4)
CURRENT[A]ACIN 100V 0.5typ 0.7typACIN 200V 0.3typ 0.4typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]ACIN 100V 75typ 80typ 79typ 80typ 81typ 82typ 83typ 83typACIN 200V 76typ 82typ 81typ 82typ 83typ 84typ 85typ 85typ
POWER FACTOR(Io=100%) ACIN 100V 0.98typ 0.99typACIN 200V 0.87typ 0.93typ
INRUSH CURRENT[A]ACIN 100V 15typ (Io=100%) (At cold start)ACIN 200V 30typ (Io=100%) (At cold start)
LEAKAGE CURRENT[mA] 0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 5 9 12 15 24 36 48CURRENT[A] 10 10 5.6 4.3 3.5 2.2 1.4 1.1LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192maxLOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max
RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max 150max-10 - 0C*1 140max 140max 160max 160max 160max 160max 200max 200max
RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 250max 250max-10 - 0C*1 160max 160max 180max 180max 180max 180max 300max 300max
TEMPERATURE REGULATION[mV]0 to +50C 50max 50max 90max 120max 150max 240max 360max 480max-10 to +50C 60max 60max 120max 150max 180max 290max 450max 600max
DRIFT[mV] *2 20max 20max 36max 48max 60max 96max 144max 192maxSTART-UP TIME[ms] 350typ(ACIN 100V, Io=100%)HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.63 4.00 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 28.8 - 39.6 39.0 - 53.0OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 9.00 - 9.36 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 35.00 - 37.44 48.00 - 49.92
PROTECTIONCIRCUIT ANDOTHERS
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 4.00 - 5.25 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 43.0 - 50.0 58.0 - 65.0OPERATING INDICATION LED (Green)REMOTE ON/OFF Optional (Required external power source)
ISOLATIONINPUT-OUTPUT-RC *3 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-FG *3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY ANDNOISEREGULATIONS
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERSCASE SIZE/WEIGHT 31X82X120mm [1.22X3.23X4.72 inches] (without terminal block) (WXHXD) / 280g max (with cover : 325g max)COOLING METHOD Convection
*6
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and
FG.*4 Derating is required.
*5 Please contact us about safety approvals for the model with option.*6 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.
PBA50FAC-DC Power Supplies Enclosed Type
PB A 50 F -5 -O
Ordering information
1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5
C : with Coating G : Low leakage current (0.15mA max / ACIN 240V) E : Low leakage current
and EMI class A (0.5mA max / ACIN 240V) T : Vertical terminal block J1 : VH (J.S.T.) connector type R : with Remote ON/OFF N : with Cover (Only 24V UL508 is acquired) N1 : with DIN rail and Cover V : Output voltage setting
potentiometer external-ly
R
1 2 3 4 5 6
High voltage pulse noise type : NAP seriesLow leakage current type : NAM series
Cover is optional
Example recommended EMI/EMC filterNAC-06-472
*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
June 25, 2020
PBA/PBW-9
Block diagram
FG
INRUSHCURRENT
LIMIT
RECTIFIERAND
FILTER
CONTROL
TRANSFORMER
CONTROL
OVER VOLTAGEPROTECTION
DC OUT
NOISEFILTER
RECTIFIERAND
FILTER
INVERTER
AC IN 85 - 264V
FUSE
RECTIFIER
CURRENTSENSING
BOOSTERINDUCTOR
INVERTER
CONTROL
CURRENTSENSING
RC
EXTERNALSOURCE
E
OPTION
250V2A
External view
PBA50F
PBA50F
A
M3
2-M3
2-M3
AC(N)
AC(L)
-V
+V
35
120
1 2
(16.5)
(21.5)
(14)
(20)
(12)
820.
5
4
(71)
77±0.5
9.5
7.5
(11)
88±0.5 11
18
313.
5
Point A
Terminal cover
Mounting hole
Mountinghole
Voltage adjust
Name plate
LED
Cover (option)
CN3Connector for Remote ON/OFF (option)
¶ Tolerance : ±1 [±0.04]
¶ External size of option T,J1,R,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
¶ Weight : 280g max (with cover : 325g max)¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.49N • m(5kgf • cm)max¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max
FG
¶ Please connect safety ground to the unit in 2-M3 holes.
Pin No. Contents12
RC(+)RC( - )
CN3 Option (Mfr : J.S.T.)
Connector type
Model B2B-XH-AMating Connector (Terminal)XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6
Barrier strip type
[0.79]
[0.65] [4.72]
[3.03] [0.16][0.55]
[0.85]
[0.43]
[2.8
]
[0.3
][0
.37]
[1.3
8]
[3.2
3][0
.02]
[0.4
7]
[3.46] [0.43]
[1.2
2]
[0.7
1]
[0.1
4]
( )
June 25, 2020
PBA/PBW-10
MODEL PBA75F-3R3 PBA75F-5 PBA75F-9 PBA75F-12 PBA75F-15 PBA75F-24 PBA75F-36 PBA75F-48MAX OUTPUT WATTAGE[W] 49.5 75 75.6 75.6 75 76.8 75.6 76.8DC OUTPUT 3.3V 15A 5V 15A 9V 8.4A 12V 6.3A 15V 5A 24V 3.2A 36V 2.1A 48V 1.6A
SPECIFICATIONSMODEL PBA75F-3R3 PBA75F-5 PBA75F-9 PBA75F-12 PBA75F-15 PBA75F-24 PBA75F-36 PBA75F-48
INPUT
VOLTAGE[V] AC85 - 264 1f or DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *4)
CURRENT[A]ACIN 100V 0.7typ 1.0typACIN 200V 0.4typ 0.5typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]ACIN 100V 77typ 81typ 80typ 81typ 82typ 83typ 84typ 84typACIN 200V 78typ 83typ 82typ 83typ 84typ 85typ 86typ 86typ
POWER FACTOR(Io=100%) ACIN 100V 0.98typ 0.99typACIN 200V 0.87typ 0.93typ
INRUSH CURRENT[A]ACIN 100V 15typ (Io=100%) (At cold start)ACIN 200V 30typ (Io=100%) (At cold start)
LEAKAGE CURRENT[mA] 0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 5 9 12 15 24 36 48CURRENT[A] 15 15 8.4 6.3 5 3.2 2.1 1.6LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192maxLOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max
RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max 150max-10 - 0C*1 140max 140max 160max 160max 160max 160max 200max 200max
RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 250max 250max-10 - 0C*1 160max 160max 180max 180max 180max 180max 300max 300max
TEMPERATURE REGULATION[mV]0 to +50C 50max 50max 90max 120max 150max 240max 360max 480max-10 to +50C 60max 60max 120max 150max 180max 290max 450max 600max
DRIFT[mV] *2 20max 20max 36max 48max 60max 96max 144max 192maxSTART-UP TIME[ms] 350typ(ACIN 100V, Io=100%)HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.63 4.00 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 28.8 - 39.6 39.0 - 53.0OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 9.00 - 9.36 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
PROTECTIONCIRCUIT ANDOTHERS
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 4.00 - 5.25 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 43.0 - 50.0 58.0 - 65.0OPERATING INDICATION LED (Green)REMOTE ON/OFF Optional (Required external power source)
ISOLATIONINPUT-OUTPUT-RC *3 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-FG *3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY ANDNOISEREGULATIONS
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERSCASE SIZE/WEIGHT 32X82X135mm [1.26X3.23X5.31 inches] (without terminal block) (WXHXD) / 350g max (with cover : 400g max)COOLING METHOD Convection
*6
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and
FG.*4 Derating is required.
*5 Please contact us about safety approvals for the model with option.*6 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.
PBA75FAC-DC Power Supplies Enclosed Type
PB A 75 F -5 -O
Ordering information
1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5
C : with Coating G : Low leakage current (0.15mA max / ACIN 240V) E : Low leakage current
and EMI class A (0.5mA max / ACIN 240V) T : Vertical terminal block J1 : VH (J.S.T.) connector type R : with Remote ON/OFF N : with Cover (Only 24V UL508 is acquired) N1 : with DIN rail and Cover V : Output voltage setting
potentiometer external-ly
R
1 2 3 4 5 6
High voltage pulse noise type : NAP seriesLow leakage current type : NAM series
Cover is optional
Example recommended EMI/EMC filterNAC-06-472
*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
June 25, 2020
PBA/PBW-11
[0.79]
[0.55]
[0.85]
[0.43]
[2.8
]
[0.65] [5.31]
[3.7] [0.16]
[0.3
][0
.37]
[1.3
8]
[3.2
3][0
.02]
[0.4
7]
[4.15] [0.35]
[1.2
6]
[0.7
1]
[0.1
4]
Point A
A
Terminal cover
M3
Mounting hole2-M3
Voltage adjust
AC(N)
AC(L)
-V
+V
¶ Tolerance : ±1 [±0.04]¶ Weight : 350g max (with cover : 400g max)¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.49N • m(5kgf • cm)max¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max
Name plate
32
18
9105.5±0.5
(16.5)
494±0.5
35
135
(21.5)
(14)
(20)
(11)
82
(12)
(71)
9.5
7.5
PBA75F
LED
Pin No. Contents12
RC(+)RC( - )
CN3 Option (Mfr : J.S.T.)
Connector type
Model B2B-XH-AMating Connector (Terminal)XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6
Barrier strip type
¶ External size of option T,J1,R,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.0.
53.
5
CN3Connector for Remote ON/OFF (option)
Cover (option)
FG
¶ Please connect safety ground to the unit in 2-M3 holes.
1 2
2-M3Mountinghole
( )
Block diagram
FG
DC OUT
AC IN 85 - 264V
RC
E
250V3.15A INRUSHCURRENT
LIMIT
RECTIFIERAND
FILTER
CONTROL
TRANSFORMER
CONTROL
OVER VOLTAGEPROTECTION
NOISEFILTER
RECTIFIERAND
FILTER
INVERTER
FUSE
RECTIFIER
CURRENTSENSING
BOOSTERINDUCTOR
INVERTER
CONTROL
CURRENTSENSING
EXTERNALSOURCE
OPTION
External view
PBA75F
June 25, 2020
PBA/PBW-12
MODEL PBA100F-3R3 PBA100F-5 PBA100F-9 PBA100F-12 PBA100F-15 PBA100F-24 PBA100F-36 PBA100F-48MAX OUTPUT WATTAGE[W] 66 100 94.5 102 105 108 100.8 100.8DC OUTPUT 3.3V 20A 5V 20A 9V 10.5A 12V 8.5A 15V 7A 24V 4.5A 36V 2.8A 48V 2.1A
SPECIFICATIONSMODEL PBA100F-3R3 PBA100F-5 PBA100F-9 PBA100F-12 PBA100F-15 PBA100F-24 PBA100F-36 PBA100F-48
INPUT
VOLTAGE[V] AC85 - 264 1f or DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *4)
CURRENT[A]ACIN 100V 0.9typ 1.3typACIN 200V 0.5typ 0.7typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]ACIN 100V 77typ 82typ 80typ 81typ 83typ 84typ 84typ 84typACIN 200V 79typ 84typ 82typ 83typ 86typ 86typ 86typ 86typ
POWER FACTOR(Io=100%) ACIN 100V 0.98typ 0.99typACIN 200V 0.87typ 0.93typ
INRUSH CURRENT[A]ACIN 100V 20typ (Io=100%) (At cold start)ACIN 200V 40typ (Io=100%) (At cold start)
LEAKAGE CURRENT[mA] 0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 5 9 12 15 24 36 48CURRENT[A] 20 20 10.5 8.5 7 4.5 2.8 2.1LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192maxLOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max
RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max 150max-10 - 0C*1 140max 140max 160max 160max 160max 160max 200max 200max
RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 250max 250max-10 - 0C*1 160max 160max 180max 180max 180max 180max 300max 300max
TEMPERATURE REGULATION[mV]0 to +50C 50max 50max 90max 120max 150max 240max 360max 480max-10 to +50C 60max 60max 120max 150max 180max 290max 450max 600max
DRIFT[mV] *2 20max 20max 36max 48max 60max 96max 144max 192maxSTART-UP TIME[ms] 350typ(ACIN 100V, Io=100%)HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.63 4.00 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 28.8 - 39.6 39.0 - 53.0OUTPUT VOLTAGE SETTING[V] 3.20 - 3.40 5.00 - 5.15 9.00 - 9.36 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
PROTECTIONCIRCUIT ANDOTHERS
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 4.00 - 5.25 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 43.0 - 50.0 58.0 - 65.0OPERATING INDICATION LED (Green)REMOTE SENSING Optional (Only -3R3, -5 Option -K)REMOTE ON/OFF Optional (Required external power source)
ISOLATIONINPUT-OUTPUT-RC *3 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-FG *3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY ANDNOISEREGULATIONS
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERSCASE SIZE/WEIGHT 32X93X147mm [1.26X3.66X5.79 inches] (without terminal block) (WXHXD) / 440g max (with cover : 500g max)COOLING METHOD Convection
*6
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and
FG.*4 Derating is required.
*5 Please contact us about safety approvals for the model with option.*6 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.
PBA100FAC-DC Power Supplies Enclosed Type
PB A 100 F -5 -O
Ordering information
1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5
C : with Coating G : Low leakage current (0.15mA max / ACIN 240V) E : Low leakage current
and EMI class A (0.5mA max / ACIN 240V) T : Vertical terminal block J1 : VH (J.S.T.) connector type (Only -12,-15,-24,-36,-48) R : with Remote ON/OFF N : with Cover (Only 24V UL508 is acquired) N1 : with DIN rail and Cover V : Output voltage setting
potentiometer external-ly
R
1 2 3 4 5 6
High voltage pulse noise type : NAP seriesLow leakage current type : NAM series
Cover is optional
Example recommended EMI/EMC filterNAC-06-472
*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
June 25, 2020
PBA/PBW-13
A
3-M3
2-M3
M4
AC(N)
AC(L)
-V
-V
+V
+V
Name plate
32
13±0
.59.
5
15112.5 ±0.5
(13.5)
124±0.5
33.5
4
(11)
(20)
(81)
(23.5)
(14)
93
(10)
147
8.6
1018
PBA100F¶ Tolerance : ±1 [±0.04]¶ Weight : 440g max (with cover : 500g max)¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.49N • m(5kgf • cm)max¶ Mounting torque : M4:1.6N • m(16.9kgf • cm)max
Point A
Terminal cover
Mounting hole
Mountinghole
Voltage adjustLED
¶ External size of option T,J1,R,N1,V and K is different from standard model and refer to 7 Option of instruction manual for details.0.
53.
5
CN4Connector for Remote sensing (option : only -3R3, -5)
CN3Connector for Remote ON/OFF (option)
Cover (option)
FG( )
¶ Please connect safety ground to FG terminal on the unit.
1 2
Pin No. Contents12
RC(+)RC( - )
CN3 Option (Mfr : J.S.T.)
Connector type
Model B2B-XH-AMating Connector (Terminal)XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6
Barrier strip type
[0.79]
[0.55]
[0.93]
[0.43]
[3.1
9]
[0.53] [5.79]
[4.88] [0.16]
[0.3
4][0
.39]
[1.3
2]
[3.6
6][0
.02]
[0.3
9][0
.71]
[4.43] [0.59]
[1.2
6]
[0.5
1][0
.37]
[0.1
4]
( )
Block diagram
FG
DC OUT
AC IN 85 - 264V
RC
E
250V3.15A INRUSHCURRENT
LIMIT
RECTIFIERAND
FILTER
CONTROL
TRANSFORMER
CONTROL
OVER VOLTAGEPROTECTION
NOISEFILTER
RECTIFIERAND
FILTER
INVERTER
FUSE
RECTIFIER
CURRENTSENSING
BOOSTERINDUCTOR
INVERTER
CONTROL
CURRENTSENSING
EXTERNALSOURCE
OPTION
External view
PBA100F
June 25, 2020
PBA/PBW-14
MODEL PBA150F-3R3 PBA150F-5 PBA150F-9 PBA150F-12 PBA150F-15 PBA150F-24 PBA150F-36 PBA150F-48MAX OUTPUT WATTAGE[W] 99 150 150.3 156 150 156 154.8 158.4DC OUTPUT 3.3V 30A 5V 30A 9V 16.7A 12V 13A 15V 10A 24V 6.5A 36V 4.3A 48V 3.3A
SPECIFICATIONSMODEL PBA150F-3R3 PBA150F-5 PBA150F-9 PBA150F-12 PBA150F-15 PBA150F-24 PBA150F-36 PBA150F-48
INPUT
VOLTAGE[V] AC85 - 264 1f or DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *4)
CURRENT[A]ACIN 100V 1.3typ 2.0typACIN 200V 0.7typ 1.0typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]ACIN 100V 80typ 83typ 82typ 83typ 84typ 85typ 85typ 85typACIN 200V 82typ 86typ 85typ 86typ 87typ 88typ 88typ 88typ
POWER FACTOR(Io=100%) ACIN 100V 0.98typ 0.99typACIN 200V 0.87typ 0.93typ
INRUSH CURRENT[A]ACIN 100V 20typ (Io=100%) (At cold start)ACIN 200V 40typ (Io=100%) (At cold start)
LEAKAGE CURRENT[mA] 0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 5 9 12 15 24 36 48CURRENT[A] 30 30 16.7 13 10 6.5 4.3 3.3LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192maxLOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max
RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max 150max-10 - 0C*1 140max 140max 160max 160max 160max 160max 200max 200max
RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 250max 250max-10 - 0C*1 160max 160max 180max 180max 180max 180max 300max 300max
TEMPERATURE REGULATION[mV]0 to +50C 50max 50max 90max 120max 150max 240max 360max 480max-10 to +50C 60max 60max 120max 150max 180max 290max 450max 600max
DRIFT[mV] *2 20max 20max 36max 48max 60max 96max 144max 192maxSTART-UP TIME[ms] 350typ(ACIN 100V, Io=100%)HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.63 4.00 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 28.8 - 39.6 39.0 - 53.0OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 9.00 - 9.36 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
PROTECTIONCIRCUIT ANDOTHERS
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 4.00 - 5.25 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 43.0 - 50.0 58.0 - 65.0OPERATING INDICATION LED (Green)REMOTE SENSING Optional (Only -3R3, -5 Option -K)REMOTE ON/OFF Optional (Required external power source)
ISOLATIONINPUT-OUTPUT-RC *3 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-FG *3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY ANDNOISEREGULATIONS
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERSCASE SIZE/WEIGHT 34X93X168mm [1.34X3.66X6.61 inches] (without terminal block) (WXHXD) / 560g max (with cover : 630g max)COOLING METHOD Convection
*6
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and
FG.*4 Derating is required.
*5 Please contact us about safety approvals for the model with option.*6 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.
PBA150FAC-DC Power Supplies Enclosed Type
PB A 150 F -5 -O
Ordering information
1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5
C : with Coating G : Low leakage current (0.15mA max / ACIN 240V) E : Low leakage current
and EMI class A (0.5mA max / ACIN 240V) T : Vertical terminal block J1 : VH (J.S.T.) connector type (Only -12,-15,-24,-36,-48) R : with Remote ON/OFF N : with Cover (Only 24V UL508 is acquired) N1 : with DIN rail and Cover V : Output voltage setting
potentiometer external-ly
R
1 2 3 4 5 6
High voltage pulse noise type : NAP seriesLow leakage current type : NAM series
Cover is optional
Example recommended EMI/EMC filterNAC-06-472
*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
June 25, 2020
PBA/PBW-15
PBA150F
9
9334
19
(13.5) 168
58.5
37.5
78±0.5 2-M3
2-M3
TB1
M4+V
+V
-V
-V
AC(L)
AC(N)
A
139.5±0.5
108.
6
(81)
(14.5)
(20.5)[0.81]
[0.57]
[0.53] [6.61]
[3.07]
[5.49] [0.35]
[2.3]
[0.94]
[3.1
9]
[1.4
8][0
.75] [1
.34]
[3.6
6][0
.02]
[0.3
4][0
.39]
[0.3
9]
[0.1
4]
(11.5)[0.45]
(24)
(10)
¶ Tolerance : ±1 [±0.04]¶ Weight : 560g max (with cover : 630g max)
¶ Keep drawing current per pin below 20A for TB1.
¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.49N • m(5kgf • cm)max¶ Mounting torque : M4:1.6N • m(16.9kgf • cm)max
Name plate
Point A
Terminal cover
Mounting hole
Mountinghole
Voltage adjust LED
¶ External size of option T,J1,R,N1,V and K is different from standard model and refer to 7 Option of instruction manual for details.
0.5
3.5
CN4Connector for Remote sensing (option : only -3R3, -5)
CN3Connector for Remote ON/OFF (option)
Cover (option)
FG( )
¶ Please connect safety ground to FG terminal on the unit.
1 2
Pin No. Contents12
RC(+)RC( - )
CN3 Option (Mfr : J.S.T.)
Connector type
Model B2B-XH-AMating Connector (Terminal)XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6
Barrier strip type
( )
Block diagram
FG
DC OUT
AC IN 85 - 264V
RC
E
250V4A INRUSHCURRENT
LIMIT
RECTIFIERAND
FILTER
CONTROL
TRANSFORMER
CONTROL
OVER VOLTAGEPROTECTION
NOISEFILTER
RECTIFIERAND
FILTER
INVERTER
FUSE
RECTIFIER
CURRENTSENSING
BOOSTERINDUCTOR
INVERTER
CONTROL
CURRENTSENSING
EXTERNALSOURCE
OPTION
External view
PBA150F
June 25, 2020
PBA/PBW-16
MODEL PBA300F-3R3 PBA300F-5 PBA300F-7R5 PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 PBA300F-48MAX OUTPUT WATTAGE[W] 198 300 300 324 330 336 324 336
DC OUTPUTACIN 100V 3.3V 60A 5V 60A 7.5V 40A 12V 27A 15V 22A 24V 14A 36V 9A 48V 7AACIN 200V*3 3.3V 60A 5V 60A 7.5V 40A 12V 27A 15V 22A 24V 14(16.5)A 36V 9A 48V 7A
SPECIFICATIONSMODEL PBA300F-3R3 PBA300F-5 PBA300F-7R5 PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 PBA300F-48
INPUT
VOLTAGE[V] AC85 - 264 1f or DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *4)
CURRENT[A]ACIN 100V 3typ 4.1typACIN 200V 1.6typ 2typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]ACIN 100V 68typ 74typ 76typ 78typ 78typ 79typ 81typ 79typACIN 200V 71typ 77typ 79typ 81typ 81typ 82typ 84typ 82typ
POWER FACTORACIN 100V 0.98typ (Io=100%)ACIN 200V 0.95typ (Io=100%)
INRUSH CURRENT[A]ACIN 100V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)ACIN 200V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
LEAKAGE CURRENT[mA] 0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48
CURRENT[A]ACIN 100V 60 60 40 27 22 14 9 7ACIN 200V*3 60 60 40 27 22 14(16.5) 9 7
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192maxLOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max
RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max 150max-20 - 0C*1 140max 140max 160max 160max 160max 160max 160max 400max
RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 200max 200max-20 - 0C*1 160max 160max 180max 180max 180max 180max 240max 500max
TEMPERATURE REGULATION[mV]0 to +50C 40max 50max 75max 120max 150max 240max 360max 480max-20 to +50C 60max 75max 120max 180max 180max 290max 440max 600max
DRIFT[mV] *2 12max 20max 30max 48max 60max 96max 144max 192maxSTART-UP TIME[ms] 300typ(ACIN 100/200V, Io=100%) *Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms] 20typ (ACIN 100/200V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
PROTECTIONCIRCUIT ANDOTHERS
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 4.3 - 6.3 6.5 - 8.0 9.0 - 11.6 14.4 - 18.6 18.0 - 23.3 28.8 - 37.2 43.2 - 54.0 57.6 - 80.0OPERATING INDICATION LED (Green)REMOTE SENSING ProvidedREMOTE ON/OFF Provided
ISOLATION
INPUT-OUTPUT-RC AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-AUX-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-AUX AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY ANDNOISEREGULATIONS
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERSCASE SIZE/WEIGHT 102X42X170mm [4.02X1.65X6.69 inches] (without terminal block and screw) (WXHXD) /1.0kg maxCOOLING METHOD Forced cooling (internal fan)
*6
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.*4 Derating is required.Consult us for details.
*5 Please contact us about safety approvals for the model with option.*6 Please contact us about class C.* A sound may occur from power supply at pulse loading.
PBA300FAC-DC Power Supplies Enclosed Type
PB A 300 F -5 -O
Ordering information
1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5
C : with Coating G : Low leakage current U : Operation stop voltage
is set at a lower value F3 : Reverse air exhaust
type F4 : Low speed fan N1 :with DIN rail
Refer to instruction manual 7.1.
R
1 2 3 4 5 6
High voltage pulse noise type : NAP seriesLow leakage current type : NAM series
Example recommended EMI/EMC filterNAC-06-472
*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
June 25, 2020
PBA/PBW-17
2-M4
4-M4Mounting Hole
Name plateCN1
Output voltageadjustable potentiometer
LED
Terminal cover
CN2CN3
Name plateM4
M4
Output terminal(+)
Output terminal(-)
AC(N)AC(L)
AIR FLOW¶ Tolerance : ±1 [±0.04]¶ Weight : 1.0kg max¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 1.2N • m max¶ Screw tightening torque : 1.6N • m max¶ The housing for the remote sensing unused is mounted on CN1
170 6max
50.5
102
42
(14)
(15.5)
8.6
(23.
5)
25max
(87)
(30)
28.5[1.12][0.61]
[0.55]
[1.18]
[2.52]
[2.91][2.13]
[0.98]
[6.69] [0.24]
[1.6
5][1
.99]
[3.4
3][2.9
5]
[0.9
3]
[1.9
7]
[0.4
7]
[0.4
7]
[0.3
4]
[0.3
9][0
.28]
[0.2
4]
[4.0
2]
[0.7
9][0
.47]
64±0.5
(6)
107
(50)
12
1220
±0.5
54 74±0.5
(75)
12
HV
.AD
J
¶ Please connect safety ground to FG terminal on the unit.
FG( )
Mounting Hole(Bottom side)
Block diagram
250V10A
INRUSHCURRENT
LIMITRECTIFIER
DC OUT
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
PG(POWER GOOD)
AUX(12V 0.1A)
±M
±S(REMOTE SENSING)
NOISEFILTER
SWITCHINGDEVICE
CONTROL
RECTIFIERAND
FILTER
RECTIFIERAND
FILTER
VOLTAGESENSING
ACTIVE FILTER
VOLTAGESENSING
CURRENTSENSING
INVERTER
CONTROL
ALARMFANINTERNALREGULATOR
CONTROL
MASTERSLAVE
CONTROL
THERMALPROTECTION
CURRENTSENSING
AC IN
FG
FUSE
85 - 264V
OVER VOLTAGEPROTECTION
External view
PBA300F
June 25, 2020
PBA/PBW-18
MODEL PBA600F-3R3 PBA600F-5 PBA600F-7R5 PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 PBA600F-48MAX OUTPUT WATTAGE[W] 396 600 600 636 645 648 648 624
DC OUTPUTACIN 100V 3.3V 120A 5V 120A 7.5V 80A 12V 53A 15V 43A 24V 27A 36V 18A 48V 13AACIN 200V*3 3.3V 120A 5V 120A 7.5V 80A 12V 53A 15V 43A 24V 27(31)A 36V 18A 48V 13A
SPECIFICATIONSMODEL PBA600F-3R3 PBA600F-5 PBA600F-7R5 PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 PBA600F-48
INPUT
VOLTAGE[V] AC85 - 264 1f or DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *5)
CURRENT[A]ACIN 100V 5.8typ 8.2typACIN 200V 3typ 4.1typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]ACIN 100V 70typ 75typ 76typ 79typ 79typ 81typ 82typ 81typACIN 200V 72typ 77typ 79typ 82typ 82typ 84typ 84typ 83typ
POWER FACTORACIN 100V 0.98typ (Io=100%)ACIN 200V 0.95typ (Io=100%)
INRUSH CURRENT[A]ACIN 100V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)ACIN 200V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)
LEAKAGE CURRENT[mA] 0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1, DENAN)
OUTPUT
VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48
CURRENT[A]ACIN 100V 120 120 80 53 43 27 18 13ACIN 200V*3 120 120 80 53 43 27(31) 18 13
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192maxLOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max
RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max 150max-20 - 0C*1 140max 140max 160max 160max 160max 160max 160max 400max
RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 200max 200max-20 - 0C*1 160max 160max 180max 180max 180max 180max 240max 500max
TEMPERATURE REGULATION[mV]0 to +50C 40max 50max 75max 120max 150max 240max 360max 480max-20 to +50C 60max 75max 120max 180max 180max 290max 440max 600max
DRIFT[mV] *2 12max 20max 30max 48max 60max 96max 144max 192maxSTART-UP TIME[ms] 400typ(ACIN 100/200V, Io=100%) *Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms] 20typ (ACIN 100/200V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
PROTECTIONCIRCUIT ANDOTHERS
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automaticallyOVERVOLTAGE PROTECTION[V] *4 Vo+0.66 - 1.32 Vo+1.0 - 2.0 Vo+1.5 - 3.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6 Vo+7.2 - 14.4 Vo+4.8 - 12.0OPERATING INDICATION LED (Green)REMOTE SENSING ProvidedREMOTE ON/OFF Provided
ISOLATION
INPUT-OUTPUT-RC AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-AUX-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-AUX AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY ANDNOISEREGULATIONS
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERSCASE SIZE/WEIGHT 120X61X190mm [4.72X2.4X7.48 inches] (without terminal block and screw) (WXHXD) /1.6kg maxCOOLING METHOD Forced cooling (internal fan)
*7
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.*4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage
protection circuit is please contact us for details.
*5 Derating is required.Consult us for details.*6 Please contact us about safety approvals for the model with option.*7 Please contact us about class C.* A sound may occur from power supply at pulse loading.
PBA600FAC-DC Power Supplies Enclosed Type
PB A 600 F -5 -O
Ordering information
1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *6
C : with Coating G : Low leakage current U : Operation stop voltage
is set at a lower value F1 : With Long-Life fan F3 : Reverse air exhaust
type F4 : Low speed fan
R
1 2 3 4 5 6
High voltage pulse noise type : NAP seriesLow leakage current type : NAM series
Refer to instruction manual 7.1.
Example recommended EMI/EMC filterNAC-16-472
*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
June 25, 2020
PBA/PBW-19
(N)
(L)A
CF
GA
C
M5
LED
CN3
CN1CN2
AC(N)
AC(L)
M4 Input terminal cover 4-M4Mounting Hole(Bottom side)
Output voltageadjustable potentiometer
Outputterminal(+)
Outputterminal(-)
AIR FLOW
8-M4Mounting Hole(Both sides)
Name plate
Name plate
Output terminal cover
¶ Tolerance : ±1 [±0.04]¶ Weight : 1.6kg max¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 1.2N · m(12.8kgf·cm)max¶ Screw tightening torque : M4 1.6N • m(16.9kgf • cm)max
¶ The housing for the remote sensing unused is mounted on CN1¶1 F1(Optional):190.5
61
17
10
(13.8)
[0.54]
[0.71][0.98]
[7.48]
[5.91][0.94]
[0.94] [5.91]
[0.24]
[0.79]
[1.91]
[2.4]
[0.5
5]
[0.4
9][1
.5]
[0.5
5][2
.07]
[3.9
4] [4.7
2]
[0.3
9]
[1.0
8]
[0.6
7]
[0.3
4]
[3.6
4]
[0.3
9][0
.28]
[0.2
4]
(18)
190 6max¶1(F1:190.5)
120
24 150±0.5
24 150±0.5
12.5
38±0
.5
25max
20max
8.7
(6)
7
1414
27.5
(52.
5)
(48.5)
(92.
5)
10
100±0
.5
FG( )
¶ Please connect safety ground to FG terminal on the unit.
M5 2.5N • m(24.5kgf • cm)max
CN
1C
N2
CN
3
Block diagram
250V15A
INRUSHCURRENT
LIMITRECTIFIER
DC OUT
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
PG(POWER GOOD)
AUX(12V 0.1A)
±M
±S(REMOTE SENSING)
NOISEFILTER
SWITCHINGDEVICE
CONTROL
RECTIFIERAND
FILTER
RECTIFIERAND
FILTER
VOLTAGESENSING
ACTIVE FILTER
VOLTAGESENSING
CURRENTSENSING
INVERTER
CONTROL
ALARMFANINTERNALREGULATOR
CONTROL
MASTERSLAVE
CONTROL
THERMALPROTECTION
CURRENTSENSING
AC IN
FG
FUSE
85 - 264V
OVER VOLTAGEPROTECTION
External view
PBA600F
June 25, 2020
PBA/PBW-20
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).
Ripple and ripple noise is measured on measuring board with capacitor of 22mF within 150mm from the output terminal.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage protection circuit is please contact us for details.
*5 Derating is required.Consult us for details.*6 Please contact us about safety approvals for the model with option.*7 Please contact us about class C.* A sound may occur from power supply at pulse loading.
PBA1000FAC-DC Power Supplies Enclosed Type
PB A 1000 F -5 -O
Ordering information
1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *6
C : with Coating G : Low leakage current U : Operation stop voltage
is set at a lower value F1 : With Long-Life fan F3 : Reverse air exhaust
type F4 : Low speed fan
R
1 2 3 4 5 6
High voltage pulse noise type : NAP seriesLow leakage current type : NAM series
Refer to instruction manual 7.1.
MODEL PBA1000F-3R3 PBA1000F-5 PBA1000F-7R5 PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36 PBA1000F-48MAX OUTPUT WATTAGE[W] 660 1000 1005 1056 1050 1056 1044 1056
DC OUTPUTACIN 100V 3.3V 200A 5V 200A 7.5V 134A 12V 88A 15V 70A 24V 44A 36V 29A 48V 22AACIN 200V*3 3.3V 200A 5V 200A 7.5V 134A 12V 88A 15V 70A 24V 44(51)A 36V 29A 48V 22A
SPECIFICATIONSMODEL PBA1000F-3R3 PBA1000F-5 PBA1000F-7R5 PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36 PBA1000F-48
INPUT
VOLTAGE[V] AC85 - 264 1f or DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *5)
CURRENT[A]ACIN 100V 9typ 13typACIN 200V 5typ 7typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]ACIN 100V 74typ 79typ 80typ 82typ 82typ 84typ 84typ 84typACIN 200V 76typ 81typ 83typ 84typ 84typ 86typ 86typ 86typ
POWER FACTORACIN 100V 0.98typ (Io=100%)ACIN 200V 0.95typ (Io=100%)
INRUSH CURRENT[A]ACIN 100V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)ACIN 200V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)
LEAKAGE CURRENT[mA] 0.5/1.0max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1, DENAN)
OUTPUT
VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48
CURRENT[A]ACIN 100V 200 200 134 88 70 44 29 22ACIN 200V*3 200 200 134 88 70 44(51) 29 22
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192maxLOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max
RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max 150max-20 - 0C*1 140max 140max 160max 160max 160max 160max 160max 400max
RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 200max 200max-20 - 0C*1 160max 160max 180max 180max 180max 180max 240max 500max
TEMPERATURE REGULATION[mV]0 to +50C 40max 50max 75max 120max 150max 240max 360max 480max-20 to +50C 60max 75max 120max 180max 180max 290max 440max 600max
DRIFT[mV] *2 12max 20max 30max 48max 60max 96max 144max 192maxSTART-UP TIME[ms] 400typ(ACIN 100/200V, Io=100%) *Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms] 20typ (ACIN 100/200V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
PROTECTIONCIRCUIT ANDOTHERS
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automaticallyOVERVOLTAGE PROTECTION[V] *4 Vo+0.66 - 1.32 Vo+1.0 - 2.0 Vo+1.5 - 3.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6 Vo+7.2 - 14.4 Vo+4.8 - 12.0OPERATING INDICATION LED (Green)REMOTE SENSING ProvidedREMOTE ON/OFF Provided
ISOLATION
INPUT-OUTPUT-RC AC3,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-AUX-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-AUX AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY ANDNOISEREGULATIONS
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERSCASE SIZE/WEIGHT 150X61X240mm [5.91X2.4X9.45 inches] (without terminal block and screw) (WXHXD) /2.2kg maxCOOLING METHOD Forced cooling (internal fan)
*7
Example recommended EMI/EMC filterNAC-20-472
*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
June 25, 2020
PBA/PBW-21
CN1
CN3CN2
AC(N)AC(L)
M4
LED
8-M4Mounting Hole(Both sides)
Name plate
Input terminal cover
Output voltageadjustable potentiometer
Output terminal(+)
Output terminal(-)
¶ Tolerance : ±1 [±0.04]¶ Weight : 2.2kg max¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 1.2N • m(12.8kgf • cm)max¶ Screw tightening torque : 1.6N • m(16.9kgf • cm)max¶ The housing for the remote sensing unused is mounted on CN1
AIR FLOW
2-M42-º9
Name plate
AC(L)
FG
AC
CN
1 H
(N)
CN
3
CN
2
V.A
DJ
Mounting Hole(Bottom side)
4-M4
79
(18)
15.85
10
51.25[2.02]
[0.3
9][0
.51]
[0.3
5][0
.3]
[3.1
1]
[0.9
4][4
.12]
[4.3
3]
[5.9
1][2
.4]
[1.5
][0
.45]
[0.7
9]
[0.1
][0
.71]
[0.9
8]
[0.62] [0.98]
[1.14]
[1.38] [9.45] [0.24]
[6.5]
[1.14][0.51][0.28] [6.5]
61
13
(25)
7
240 6max
150
25max20
(35)
(7.5
)13
9
29 165±0.5
11.5
38±0
.5
104.
75(2
4)
110±0
.5
29 165 ±0.5
2.5
FG( )
¶ Please connect safety ground to FG terminal on the unit.
[0.35]
Block diagram
250V30A
INRUSHCURRENT
LIMITRECTIFIER
DC OUT
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
PG(POWER GOOD)
AUX(12V 0.1A)
±M
±S(REMOTE SENSING)
NOISEFILTER
SWITCHINGDEVICE
CONTROL
RECTIFIERAND
FILTER
RECTIFIERAND
FILTER
VOLTAGESENSING
ACTIVE FILTER
VOLTAGESENSING
CURRENTSENSING
INVERTER
CONTROL
ALARMFANINTERNALREGULATOR
CONTROL
MASTERSLAVE
CONTROL
THERMALPROTECTION
CURRENTSENSING
AC IN
FG
FUSE
85 - 264V
OVER VOLTAGEPROTECTION
External view
PBA1000F
June 25, 2020
PBA/PBW-22
MODEL PBA1500F-3R3 PBA1500F-5 PBA1500F-7R5 PBA1500F-12 PBA1500F-15 PBA1500F-24 PBA1500F-36 PBA1500F-48MAX OUTPUT WATTAGE[W] 990 1500 1500 1500 1500 1680 1692 1680
DC OUTPUTACIN 100V 3.3V 300A 5V 300A 7.5V 200A 12V 125A 15V 100A 24V 65A 36V 42A 48V 32AACIN 200V*3 3.3V 300A 5V 300A 7.5V 200A 12V 125A 15V 100A 24V 70(105)A 36V 47(70)A 48V 35A
SPECIFICATIONSMODEL PBA1500F-3R3 PBA1500F-5 PBA1500F-7R5 PBA1500F-12 PBA1500F-15 PBA1500F-24 PBA1500F-36 PBA1500F-48
INPUT
VOLTAGE[V] AC85 - 264 1f or DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 7. option *5)
CURRENT[A]ACIN 100V 15typ 19typACIN 200V 8typ 10typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]ACIN 100V 72typ 77typ 81typ 81typ 83typ 84typ 84typ 84typACIN 200V 75typ 81typ 83typ 84typ 86typ 87typ 87typ 87typ
POWER FACTORACIN 100V 0.98typ (Io=100%)ACIN 200V 0.95typ (Io=100%)
INRUSH CURRENT[A]ACIN 100V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)ACIN 200V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)
LEAKAGE CURRENT[mA] 0.9/1.5max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1, DENAN)
OUTPUT
VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48
CURRENT[A]ACIN 100V 300 300 200 125 100 65 42 32ACIN 200V*3 300 300 200 125 100 70(105) 47(70) 35
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192maxLOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max
RIPPLE[mVp-p]0 to +50C*1 80max 80max 120max 120max 120max 120max 150max 150max-20 - 0C*1 140max 140max 160max 160max 160max 160max 160max 400max
RIPPLE NOISE[mVp-p]0 to +50C*1 120max 120max 150max 150max 150max 150max 200max 200max-20 - 0C*1 160max 160max 180max 180max 180max 180max 240max 500max
TEMPERATURE REGULATION[mV]0 to +50C 40max 50max 75max 120max 150max 240max 360max 480max-20 to +50C 60max 75max 120max 180max 180max 290max 440max 600max
DRIFT[mV] *2 12max 20max 30max 48max 60max 96max 144max 192maxSTART-UP TIME[ms] 600typ(ACIN 100/200V, Io=100%)HOLD-UP TIME[ms] 20typ (ACIN 100/200V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
PROTECTIONCIRCUIT ANDOTHERS
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automaticallyOVERVOLTAGE PROTECTION[V] *4 Vo+0.66 - 1.32 Vo+1.0 - 2.0 Vo+1.5 - 3.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6 Vo+7.2 - 14.4 Vo+4.8 - 12.0OPERATING INDICATION LED (Green)REMOTE SENSING ProvidedREMOTE ON/OFF Provided
ISOLATION
INPUT-OUTPUT-RC AC3,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-AUX-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-AUX AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY ANDNOISEREGULATIONS
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B, additional EMI/EMC Filter required for meeting class BHARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERSCASE SIZE/WEIGHT 178X61X268mm [7.01X2.4X10.55 inches] (without terminal block and screw) (WXHXD) /3.4kg maxCOOLING METHOD Forced cooling (internal fan)
*7
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).
Ripple and ripple noise is measured on measuring board with capacitor of 22mF within 150mm from the output terminal.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage protection circuit is please contact us for details.
*5 Derating is required.Consult us for details.*6 Please contact us about safety approvals for the model with option.*7 Please contact us about class C.* A sound may occur from power supply at pulse loading.
PBA1500FAC-DC Power Supplies Enclosed Type
PB A 1500 F -5 -O
Ordering information
1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *6
C : with Coating G : Low leakage current U : Operation stop voltage
is set at a lower value F1 : With Long-Life fan F3 : Reverse air exhaust
type F4 : Low speed fan
R
1 2 3 4 5 6
High voltage pulse noise type : NAP seriesLow leakage current type : NAM series
Refer to instruction manual 7.1.
Example recommended EMI/EMC filterNAC-20-472
*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
June 25, 2020
PBA/PBW-23
Name plate
(N)
V.AD
J
FG
NC
AC
(L)A
CC
N1
CN
2
CN
3
CN1
4-M4
2-º9
CN3CN2
NC
AC(N)
AC(L)
¶ Tolerance : ±1 [±0.04]¶ Weight : 3.4kg max¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 1.2N • m(12.8kgf • cm)max¶ Screw tightening torque : 1.6N • m(16.9kgf • cm)max¶ The housing for the remote sensing unused is mounted on CN1
Output voltageadjustable potentiometer
Name plate
AIR FLOW
8-M4
8-M4
Mounting Hole(Both sides)
M4Input terminal cover
Output terminal(+)
Output terminal(-)
LED
107
1013
9(7
.5)15.85
(25)
(18)
1510
4
(24)
132
171.5 ±0.519
152.
4±0
.5
268 6max
178
19 171.5 ±0.5
11.5
38±0
.5
(45)
61
12.8
25max
51.25
FG( )
¶ Please connect safety ground to FG terminal on the unit.
Mounting Hole(Both sides)[0.62]
[2.02]
[0.98]
[0.75] [6.75]
[0.75][0.59][0.39]
[0.35]
[6.75]
[1.77] [0.24][10.55]
[4.2
1]
[5.2
]
[6]
[0.5
]
[7.0
1][2
.4]
[1.5
][0
.45]
[0.9
4]
[0.9
8][0
.71]
[0.1
6]
[0.3
9][0
.51]
[0.3
5][0
.3]
Block diagram
250V30A
INRUSHCURRENT
LIMITRECTIFIER
DC OUT
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
PG(POWER GOOD)
AUX(12V 0.1A)
±M
±S(REMOTE SENSING)
NOISEFILTER
SWITCHINGDEVICE
CONTROL
RECTIFIERAND
FILTER
RECTIFIERAND
FILTER
VOLTAGESENSING
ACTIVE FILTER
VOLTAGESENSING
CURRENTSENSING
INVERTER
CONTROL
ALARMFANINTERNALREGULATOR
CONTROL
MASTERSLAVE
CONTROL
THERMALPROTECTION
CURRENTSENSING
AC IN
FG
FUSE
85 - 264V
OVER VOLTAGEPROTECTION
External view
PBA1500F
June 25, 2020
PBA/PBW-24
MODEL PBA1500T-5 PBA1500T-12 PBA1500T-24 PBA1500T-48MAX OUTPUT WATTAGE[W] 1500 1500 1680 1680DC OUTPUT ACIN 200V*3 5V 300A 12V 125A 24V 70(105)A 48V 35A
SPECIFICATIONSMODEL PBA1500T-5 PBA1500T-12 PBA1500T-24 PBA1500T-48
INPUT
VOLTAGE[V] AC170 - 264 3f (AC100 Please refer to the instruction manual 7. option *5)
CURRENT[A] ACIN 200V 6typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%] ACIN 200V 81typ 84typ 87typ 87typ
POWER FACTOR ACIN 200V 0.95typ (Io=100%)
INRUSH CURRENT[A] ACIN 200V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)
LEAKAGE CURRENT[mA] 1.5max (ACIN 240V 60Hz, Io=100%, According to IEC60950-1, DENAN)
OUTPUT
VOLTAGE[V] 5 12 24 48
CURRENT[A] ACIN 200V*3 300 125 70(105) 35
LINE REGULATION[mV] 20max 48max 96max 192max
LOAD REGULATION[mV] 40max 100max 150max 300max
RIPPLE[mVp-p]0 to +50C*1 80max 120max 120max 150max
-20 - 0C*1 140max 160max 160max 400max
RIPPLE NOISE[mVp-p]0 to +50C*1 120max 150max 150max 200max
-20 - 0C*1 160max 180max 180max 500max
TEMPERATURE REGULATION[mV]0 to +50C 50max 120max 240max 480max
-20 to +50C 75max 180max 290max 600max
DRIFT[mV] *2 20max 48max 96max 192max
START-UP TIME[ms] 300typ(ACIN 200V, Io=100%) *Start-up time is 500ms typ for less than 1 minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms] 20typ (ACIN 200V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 3.96 - 6.00 8.25 - 13.20 16.50 - 26.40 38.40 - 56.00
OUTPUT VOLTAGE SETTING[V] 5.00 - 5.15 12.00 - 12.48 24.00 - 24.96 48.00 - 49.92
PROTECTIONCIRCUIT ANDOTHERS
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
OVERVOLTAGE PROTECTION[V] *4 Vo+1.0 - 2.0 Vo+2.4 - 4.8 Vo+4.8 - 9.6 Vo+2.0 - 12.0
OPERATING INDICATION LED (Green)
REMOTE SENSING Provided
REMOTE ON/OFF Provided
ISOLATION
INPUT-OUTPUT-RC AC3,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDNOISEREGULATIONS
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B, additional EMI/EMC Filter required for meeting class B
OTHERSCASE SIZE/WEIGHT 178X61X268mm [7.01X2.4X10.55 inches] (without terminal block and screw) (WXHXD) /3.4kg max
COOLING METHOD Forced cooling (internal fan)
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101).
Ripple and ripple noise is measured on measuring board with capacitor of 22mF within 150mm from the output terminal.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage protection circuit is please contact us for details.
*5 Derating is required.Consult us for details.*6 Please contact us about safety approvals for the model with option.* A sound may occur from power supply at pulse loading.
PBA1500TAC-DC Power Supplies Enclosed Type
PB A 1500 T -5 -O
Ordering information
1 Series name2 Single output3 Output wattage4 Triple input phase5 Output voltage6 Optional *6
C : with Coating G : Low leakage current U : Operation stop voltage
is set at a lower value F1 : With Long-Life fan F3 : Reverse air exhaust
type F4 : Low speed fan
R
1 2 3 4 5 6
Refer to instruction manual 7.1.
Example recommended EMI/EMC filterTAC-10-683
*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
June 25, 2020
PBA/PBW-25
Name plate
(L2)
V.AD
J
FG
(L3)A
C(L1)
CN
1
CN
2
CN
3
CN1
4-M4
2-º9
CN3CN2
AC(L3)
AC(L2)
AC(L1)
¶ Tolerance : ±1 [±0.04]¶ Weight : 3.4kg max¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 1.2N • m(12.8kgf • cm)max¶ Screw tightening torque : 1.6N • m(16.9kgf • cm)max¶ The housing for the remote sensing unused is mounted on CN1
Output voltageadjustable potentiometer
Name plate
AIR FLOW
8-M4
8-M4
Mounting Hole(Both sides)
M4Input terminal cover
Output terminal(+)
Output terminal(-)
LED
107
1013
9(7
.5)15.85
(25)
(18)
1510
4(24)
132
171.5 ±0.519
152.
4±0
.5
268 6max
178
19 171.5 ±0.5
11.5
38±0
.5
(45)
61
12.825max
51.25
FG( )
¶ Please connect safety ground to unit in M4 holes.
Mounting Hole(Both sides)[0.62]
[2.02]
[4.2
1]
[0.3
9][0
.51]
[0.3
5][0
.3]
[0.98]
[0.75] [6.75]
[1.77] [0.24][10.55]
[5.2
]
[6]
[0.5
]
[7.0
1]
[0.9
4]
[0.1
6]
[0.75][0.59][0.39]
[0.35]
[6.75]
[2.4
]
[1.5
][0
.45]
[0.9
8][0
.71]
Block diagram
AC250V16A
INRUSHCURRENT
LIMITRECTIFIER
DC OUT
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
PG(POWER GOOD)
AUX(12V 0.1A)
±M(MONITOR)
±S(REMOTE SENSING)
NOISEFILTER
SWITCHINGDEVICE
CONTROL
RECTIFIERAND
FILTER
RECTIFIERAND
FILTER
VOLTAGESENSING
ACTIVE FILTER
VOLTAGESENSING
CURRENTSENSING
INVERTER
CONTROL
ALARMFAN
OPENPHASE
INTERNALREGULATOR
CONTROL
MASTERSLAVE
CONTROL
THERMALPROTECTION
CURRENTSENSING
AC IN
(3º)
FG
FUSE
170 - 264V
OVER VOLTAGEPROTECTION
External view
PBA1500T
June 25, 2020
PBA/PBW-26
MODEL PBW15F-12 PBW15F-15MAX OUTPUT WATTAGE[W] *5 16.8 15.0
DC OUTPUTVOLTAGE[V] *6 t12 ( +24 ) t15 ( +30 )CURRENT1[A] 0.7 0.5CURRENT2[A]*5 1.4 1.0
SPECIFICATIONSMODEL PBW15F-12 PBW15F-15
INPUT
VOLTAGE[V] AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *8)
CURRENT[A]ACIN 100V 0.40typ (CURRENT1)ACIN 200V 0.20typ (CURRENT1)
FREQUENCY[Hz] 50/60 (47 - 440) or DC
EFFICIENCY[%]ACIN 100V 74typ (CURRENT1) 78typ (CURRENT1)ACIN 200V 77typ (CURRENT1) 80typ (CURRENT1)
INRUSH CURRENT[A]ACIN 100V 15typ (CURRENT1) (At cold start)ACIN 200V 30typ (CURRENT1) (At cold start)
LEAKAGE CURRENT[mA] 0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] t12 / ( +24V reference number ) t15 / ( +30V reference number )CURRENT1[A] 0.7 / 0.7 0.5 / 0.5CURRENT2[A] *5 1.4 / - 1.0 / -LINE REGULATION[mV] *9 60max / 96max 60max / 96maxLOAD REGULATION 1[mV] *3 600max / 150max 600max / 150maxLOAD REGULATION 2[mV] *4
*11
*11
*11 750max / - 750max / -
RIPPLE[mVp-p]0 to +50C*1 120max / 240max 120max / 240max-10 - 0C*1 160max / 320max 160max / 320max
RIPPLE NOISE[mVp-p]0 to +50C*1 150max / 300max 150max / 300max-10 - 0C*1 180max / 360max 180max / 360max
TEMPERATURE REGULATION[mV]0 to +50C 120max 150max-10 to +50C 150max 180max
DRIFT[mV] *2 48max 60maxSTART-UP TIME[ms] 200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 9.60 - 13.2 (+V and -V are simultaneously adjusted) 13.2 - 16.5 (+V and -V are simultaneously adjusted)OUTPUT VOLTAGE SETTING[V] 11.5 - 12.5 (+V and -V CURRENT1) 14.4 - 15.6 (+V and -V CURRENT1)
PROTECTIONCIRCUIT ANDOTHERS
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 16.8 - 24.0 20.0 - 29.0OPERATING INDICATION LED (Green)REMOTE ON/OFF None
ISOLATIONINPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY ANDNOISEREGULATIONS
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2 (Not built-in to active filter *7)
OTHERSCASE SIZE/WEIGHT 31X78X85mm [1.22X3.07X3.35 inches] (without terminal block) (WXHXD) / 200g max (with cover : 235g max)COOLING METHOD Convection
*12
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 Figures for 0 to rated current 1.The current not measured side is fixed.
*4 Figures for 0 to rated current 2.The current not measured
side is fixed.*5 The sum of +power -power must be less than output power.*6 t12,t15 can be used as +24 and +30. *7 When two or more units are used,they may not comply with
the harmonic attenuator. Please contact us for details.*8 Derating is required.*9 Figures to rated current 1.
*10 Please contact us about safety approvals for the model with option.
*11 Please contact us about dynamic load and input response.*12 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.
PBW15FAC-DC Power Supplies Enclosed Type
PB W 15 F -O -O
Ordering information
1 Series name2 Dual output3 Output wattage4 Universal input5 Output voltage6 Optional *10
C : with Coating G : Low leakage current E : Low leakage current
and EMI class A T : Vertical terminal block J1 : VH (J.S.T.) connector type N : with Cover N1 : with DIN rail V : Output voltage setting
potentiometer external-ly
R
1 2 3 4 5 6
High voltage pulse noise type : NAP seriesLow leakage current type : NAM series
Cover is optional
Example recommended EMI/EMC filterNAC-06-472
*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
June 25, 2020
PBA/PBW-27
2.5
Point A:C102
Mounting hole2-M3
Mounting hole2-M3
-V
AC(N)
AC(L)
FG
COM
+V
Cover name plate
Cover (option)
Name plate
M3
Terminal cover
5
18
31 34.5
34.5
78
36.5
85
70.5
12.2±1.5
18
31±0.5
60±0.5
11.5
9.5
7.5
16.5±2
15.1±1.5
22.6±1.5
PBA15FPBW15F
LED
Voltage adjust
¶ Tolerance : ±1 [±0.04]¶ Weight : 200g max (with cover : 235g max)¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.6N • m(6.3kgf • cm)max¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max¶ Please connect safety ground to the unit in 2-M3 holes.
¶ External size of option T,J1,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
[0.71]
[2.7
8]
[0.3
][0
.37]
[0.4
5]
[1.3
6][0
.71] [1
.22]
[1.3
6]
[3.0
7]
[0.48]
[0.59]
[0.89]
[0.1]
[0.65] [3.35]
[1.22]
[2.36] [0.2]
[1.44]
Block diagram
2.5AAC250V
AC IN
+V
COM DCOUT
-V
FG
85 - 264VNOISEFILTER
INVERTERCONTROL
CURRENTSENSING
RECTIFIERAND
FILTER
RECTIFIERAND
FILTER
CONTROL
Photocoupler
Photocoupler
TRANSFORMER
INRUSHCURRENT
LIMIT
FUSE
OVER VOLTAGEPROTECTION
RECTIFIERAND
FILTER
External view
PBW15F
June 25, 2020
PBA/PBW-28
MODEL PBW30F-5 PBW30F-12 PBW30F-15MAX OUTPUT WATTAGE[W] *5 15 31.2 30.0
DC OUTPUTVOLTAGE[V] *6 t5 ( +10 ) t12 ( +24 ) t15 ( +30 )CURRENT1[A] 1.5 1.3 1.0CURRENT2[A]*5 2.0 1.7 1.4
SPECIFICATIONSMODEL PBW30F-5 PBW30F-12 PBW30F-15
INPUT
VOLTAGE[V] AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *8)
CURRENT[A]ACIN 100V 0.4typ (CURRENT1) 0.7typ (CURRENT1)ACIN 200V 0.25typ (CURRENT1) 0.4typ (CURRENT1)
FREQUENCY[Hz] 50/60 (47 - 440) or DC
EFFICIENCY[%]ACIN 100V 75typ (CURRENT1) 77typ (CURRENT1) 78typ (CURRENT1)ACIN 200V 75typ (CURRENT1) 81typ (CURRENT1) 79typ (CURRENT1)
INRUSH CURRENT[A]ACIN 100V 15typ (CURRENT1) (At cold start)ACIN 200V 30typ (CURRENT1) (At cold start)
LEAKAGE CURRENT[mA] 0.30/0.65max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] t5 / ( +10V reference number ) t12 / ( +24V reference number ) t15 / ( +30V reference number )CURRENT1[A] 1.5 / 1.5 1.3 / 1.3 1.0 / 1.0CURRENT2[A] *5 2.0 / - 1.7 / - 1.4 / -LINE REGULATION[mV] 20max / 36max 60max / 96max 60max / 96maxLOAD REGULATION 1[mV] 250max / 100max 600max / 150max 600max / 150maxLOAD REGULATION 2[mV] 500max / - 750max / - 750max / -
RIPPLE[mVp-p]0 to +50C*1 80max / 240max 120max / 240max 120max / 240max-10 - 0C*1 140max / 320max 160max / 320max 160max / 320max
RIPPLE NOISE[mVp-p]0 to +50C*1 120max / 300max 150max / 300max 150max / 300max-10 - 0C*1 160max / 360max 180max / 360max 180max / 360max
TEMPERATURE REGULATION[mV]0 to +50C 50max 120max 150max-10 to +50C 60max 150max 180max
DRIFT[mV] *2 20max 48max 60maxSTART-UP TIME[ms] 200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.99 - 6.00 (+V and -V are simultaneously adjusted) 9.60 - 13.2 (+V and -V are simultaneously adjusted) 13.2 - 16.5 (+V and -V are simultaneously adjusted)OUTPUT VOLTAGE SETTING[V] 4.99 - 5.30 (+V and -V CURRENT1) 11.5 - 12.5 (+V and -V CURRENT1) 14.4 - 15.6 (+V and -V CURRENT1)
PROTECTIONCIRCUIT ANDOTHERS
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 6.90 - 10.0 16.8 - 24.0 20.0 - 29.0OPERATING INDICATION LED (Green)REMOTE ON/OFF None
ISOLATIONINPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY ANDNOISEREGULATIONS
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2 (Not built-in to active filter *7)
OTHERSCASE SIZE/WEIGHT 31X78X103mm [1.22X3.07X4.06 inches] (without terminal block) (WXHXD) / 270g max (with cover : 310g max)COOLING METHOD Convection
*9
*3
*4
*11
*11
*11
*12
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 Figures for 0 to rated current 1.The current not measured side is fixed.
*4 Figures for 0 to rated current 2.The current not measured
side is fixed.*5 The sum of +power -power must be less than output power.*6 t5,t12,t15 can be used as +10,+24 and +30. *7 When two or more units are used,they may not comply with
the harmonic attenuator. Please contact us for details.*8 Derating is required.*9 Figures to rated current 1.
*10 Please contact us about safety approvals for the model with option.
*11 Please contact us about dynamic load and input response.*12 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.
PBW30FAC-DC Power Supplies Enclosed Type
PB W 30 F -O -O
Ordering information
1 Series name2 Dual output3 Output wattage4 Universal input5 Output voltage6 Optional *10
C : with Coating G : Low leakage current E : Low leakage current
and EMI class A T : Vertical terminal block J1 : VH (J.S.T.) connector type N : with Cover N1 : with DIN rail V : Output voltage setting
potentiometer external-ly
R
1 2 3 4 5 6
High voltage pulse noise type : NAP seriesLow leakage current type : NAM series
Cover is optional
Example recommended EMI/EMC filterNAC-06-472
*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
June 25, 2020
PBA/PBW-29
2.5
Mounting hole2-M3
Mounting hole2-M3
Point A:C102
Name plate
Cover name plate
Cover (option)
M3
Terminal cover
-V
AC(N)
AC(L)
FG
COM
+V
18
12.2±1.5
70.5
1836
.5
46±0.5 40.5
75±0.5 8.5
15.1±1.5
22.6±1.5
11.5
9.5
7.5
16.5±2
31
103
78
34.5
PBW30FPBA30F
¶ Tolerance : ±1 [±0.04]¶ Weight : 270g max (with cover : 310g max)¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.6N • m(6.3kgf • cm)max¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max¶ Please connect safety ground to the unit in 2-M3 holes.
¶ External size of option T,J1,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
LED
Voltage adjust[0.71]
[2.7
8]
[0.48]
[0.59]
[0.89]
[0.1]
[0.3
][0
.37]
[0.4
5]
[1.4
4]
[3.0
7]
[0.65] [4.06]
[1.81] [1.59]
[0.7
1] [1.2
2]
[1.3
6]
[2.95] [0.33]
Block diagram
3.15AAC250V
NOISEFILTER
AC IN
+V
COM DCOUT
-V
FG
85 - 264VNOISEFILTER
INVERTERCONTROL
CURRENTSENSING
RECTIFIERAND
FILTER
RECTIFIERAND
FILTER
CONTROL
Photocoupler
Photocoupler
TRANSFORMER
INRUSHCURRENT
LIMIT
FUSE
OVER VOLTAGEPROTECTION
RECTIFIERAND
FILTER
External view
PBW30F
June 25, 2020
PBA/PBW-30
MODEL PBW50F-5 PBW50F-12 PBW50F-15MAX OUTPUT WATTAGE[W] *6 30 50.4 51
DC OUTPUTVOLTAGE[V] *8 t5 ( +10 ) t12 ( +24 ) t15 ( +30 )CURRENT1[A] 3.0 2.1 1.7CURRENT2[A]*6 4.0 2.7 2.4
SPECIFICATIONSMODEL PBW50F-5 PBW50F-12 PBW50F-15
INPUT
VOLTAGE[V] AC85 - 264 1f or DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *3)
CURRENT[A]ACIN 100V 0.45typ (CURRENT1) 0.70typ (CURRENT1)ACIN 200V 0.30typ (CURRENT1) 0.40typ (CURRENT1)
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]ACIN 100V 76typ (CURRENT1) 81typ (CURRENT1) 81typ (CURRENT1)ACIN 200V 77typ (CURRENT1) 83typ (CURRENT1) 83typ (CURRENT1)
POWER FACTOR(Io=100%) ACIN 100V 0.98typ 0.99typACIN 200V 0.87typ 0.93typ
INRUSH CURRENT[A]ACIN 100V 15typ (CURRENT1) (At cold start)ACIN 200V 30typ (CURRENT1) (At cold start)
LEAKAGE CURRENT[mA] 0.40/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] t5 / ( +10V reference number ) t12 / ( +24V reference number ) t15 / ( +30V reference number )CURRENT1[A] 3.0 / 3.0 2.1 / 2.1 1.7 / 1.7CURRENT2[A] *6 4.0 / - 2.7 / - 2.4 / -LINE REGULATION[mV] 20max / 36max 48max / 96max 60max / 96maxLOAD REGULATION 1[mV] *4 250max / 100max 600max / 150max 600max / 150maxLOAD REGULATION 2[mV] *5 500max / - 750max / - 750max / -
RIPPLE[mVp-p]0 to +50C*1 80max / 240max 120max / 240max 120max / 240max-10 - 0C*1 140max / 320max 160max / 320max 160max / 320max
RIPPLE NOISE[mVp-p]0 to +50C*1 120max / 300max 150max / 300max 150max / 300max-10 - 0C*1 160max / 360max 180max / 360max 180max / 360max
TEMPERATURE REGULATION[mV]0 to +50C 50max 120max 150max-10 to +50C 60max 150max 180max
DRIFT[mV] *2 20max 48max 60maxSTART-UP TIME[ms] 350typ(ACIN 100V, Io=100%)HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.99 - 6.00 (+V and -V are simultaneously adjusted) 9.60 - 13.2 (+V and -V are simultaneously adjusted) 13.2 - 16.5 (+V and -V are simultaneously adjusted)OUTPUT VOLTAGE SETTING[V] 4.99 - 5.30 (+V and -V CURRENT1) 11.5 - 12.5 (+V and -V CURRENT1) 14.4 - 15.6 (+V and -V CURRENT1)
PROTECTIONCIRCUIT ANDOTHERS
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 6.90 - 10.0 16.8 - 24.0 20.0 - 29.0OPERATING INDICATION LED (Green)REMOTE ON/OFF Optional (Required external power source)
ISOLATIONINPUT-OUTPUT-RC *7 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)OUTPUT-RC-FG *7 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Refer to “Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxVIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY ANDNOISEREGULATIONS
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-ANCONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERSCASE SIZE/WEIGHT 31X82X120mm [1.22X3.23X4.72 inches] (without terminal block) (WXHXD) / 280g max (with cover : 325g max)COOLING METHOD Convection
*10
PBW50FAC-DC Power Supplies Enclosed Type
PB W 50 F -O -O
Ordering information
1 Series name2 Dual output3 Output wattage4 Universal input5 Output voltage6 Optional *9
C : with Coating G : Low leakage current (0.15mA max / ACIN 240V) E : Low leakage current
and EMI class A (0.5mA max / ACIN 240V) T : Vertical terminal block J1 : VH (J.S.T.) connector type R : with Remote ON/OFF N : with Cover N1 : with DIN rail V : Output voltage setting
potentiometer external-ly
R
1 2 3 4 5 6
High voltage pulse noise type : NAP seriesLow leakage current type : NAM series
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 Derating is required.*4 Figures for 0 to rated current 1.The current not measured
side is fixed.
*5 Figures for 0 to rated current 2.The current not measured side is fixed.
*6 The sum of +power -power must be less than output power.*7 RC is applied to remote ON/OFF option. RC is isolated with
input/output and FG.*8 t5,t12,t15 can be used as +10,+24 and +30.
*9 Please contact us about safety approvals for the model with option.
*10 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.
Cover is optional
Example recommended EMI/EMC filterNAC-06-472
*A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
June 25, 2020
PBA/PBW-31
¶ Tolerance : ±1 [±0.04]¶ Weight : 280g max (with cover : 325g max)¶ PCB Material/thickness : CEM3 / 1.6mm [0.06]¶ Chassis material : Aluminum¶ Dimensions in mm, [ ]= inches¶ Mounting torque : 0.49N • m(5kgf • cm)max¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max¶ Please connect safety ground to the unit in 2-M3 holes.
¶ External size of option T,J1,R,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
LEDVoltage adjust
PBW50F
-V
CN3Connector for Remote ON/OFF (option)
21
Cover name plate
Cover (option)
A
Name plate
M3
Mounting hole2-M3
Mounting hole2-M3
AC(N)
AC(L)
FG
COM
+V
Terminal cover
Point A
(16.5)
9.5
(12)
(20)
(11)
(71)
(21.5)
(14)
82
34.5
35
120
477±0.5
7.5
88 ±0.5 11
18
310.
5
Pin No. Contents12
RC(+)RC(- )
CN3 Option (Mfr : J.S.T.)
Connector type
Model B2B-XH-AMating Connector (Terminal)XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6
Barrier strip type
[0.79]
[0.65] [4.72]
[3.03] [0.16]
[0.43][3.46]
[0.43]
[2.8
]
[0.3
][0
.37]
[0.4
7]
[1.3
8]
[3.2
3]
[0.7
1] [1.2
2]
[1.3
6]
[0.0
2]
[0.55]
[0.85]
( )
Block diagram
FG
CONTROL
TRANSFORMER
CONTROL
+DC OUT
NOISEFILTER
-DC OUT
INVERTER
AC IN 85 - 264V
FUSE
RECTIFIER
BOOSTERINDUCTOR
INVERTER
CONTROL
RC
EXTERNALSOURCE
E
OPTION
250V2A
RECTIFIERAND
FILTER
RECTIFIERAND
FILTER
INRUSHCURRENT
LIMIT
RECTIFIERAND
FILTER
OVER VOLTAGEPROTECTION
CURRENTSENSING
CURRENTSENSING
External view
PBW50F
June 25, 2020
*The following information covers PBA300F - 1500F. Please see External View for PBA10F - 150F and PBW15F - 50F.
*PBA300F - 1500F *PBA1500T
¿ PBA1000F
¿ PBA600F
¿ PBA1500F
¿ PBA300F
( N)( L)AC
FGAC
CN1CN2CN3
1 2
7 89å 0
4 5 6
1AC (L) Input Terminals AC85 - 264V f47 - 63Hz2AC (N) (M4)3NC4Frame ground (M4 )5-Output6+Output7LED8Output voltage adjustable potentiometer9CN10CN2 ConnectorsåCN3*Please see Optional Parts for dedicated harnesses.
1 2
7 89
4 5 6
å 0
HV. ADJ
1 2 5 6
789å 0
4
AC(L) FG
ACCN1
H
(N)
CN3
CN2
V. ADJ
1 2 3 5 6
789å 0
4
( N)
V. ADJ
FGNCAC
( L)AC
CN1
CN2
CN3
¿ PBA1500T
1AC (L1) 2AC (L2)3AC (L3)4Frame ground (M4 )5-Output6+Output7LED8Output voltage adjustable potentiometer9CN10CN2 ConnectorsåCN3
1 2 3 5 6
789å 0
4
(L2)
V.ADJ
FG(L3)AC
(L1)
CN1
CN2
CN3
PBA/PBW-32
Terminal Blocks
PBA∙PBW-series
June 25, 2020
Installation Method¡Do not insert a screw more than 6mm from the outside of a power
supply to keep enough insulation distance between the screw and internal components.
¿ PBA10F, PBA15F, PBW15F, PBA30F, PBW30F, PBA50F, PBW50F, PBA75F, PBA100F and PBA150F
¡If you use two or more power supplies side by side, please keep a sufficient distance between them to allow enough air ventilation.
¡Ambient temperature around each power supply should not ex-ceed the temperature range shown in ‟derating”.
¿ PBA300F, PBA600F, PBA1000F, PBA1500F and PBA1500T¡The power supplies have a built-in forced cooling fan. Do not block ventilation at the suction side (terminal block side) and its opposite
side (fan installation side). If you need to secure a power supply by screws, securely fix it, taking into consideration of its weight. You can install it in any direction.
¡If you use a power supply in a dusty environment, it can give a cause for a failure. Please consider taking such countermeasures as in-stalling an air filter near the suction area of the system to prevent a failure.
¡In PBA300F, PBA1500F and PBA1500T, ventilation holes are located on the mounting side. If you would like to install the unit by using that side, please contact us for details.
PCB
2
1CN3 CN2 CN1
10
9
2
1
10
9
2
1
8
7
1
91
91
7
2
CN1
PCB
CN2
CN3
102
102
8
¿ PBA300F, 600F Pin Configuration
¿ PBA1000F, 1500F Pin Configuration
Pin Configuration and Functions of CN1 and CN2Pin No. Function
1 +M : Self sensing terminal. (Do not wire for external connection.)2 +S : +Sensing3 -M : Self sensing terminal. (Do not wire for external connection.)4 -S : -Sensing5 VB : Voltage balance6 CB : Current balance7 TRM : Adjustment of output voltage8 -S : -Sensing9 RC2 : Remote ON/OFF
10 RCG : Remote ON/OFF (GND)
Pin Configuration and Functions of CN3Pin No. Function
1 -S : -Sensing2 -S : -Sensing3 AUX : Auxiliary output (12V 0.1A)4 RC1 : Remote ON/OFF5 AUXG : Auxiliary output (GND)6 N.C. : No connection7 PG : Alarm8 PGG : Alarm (GND)
* Common signs among CN1, CN2 and CN3 such as -S represent the same potential.
Matching connecters and terminals on CN1, CN2 and CN3Connector Housing Terminal Mfr.
CN1S10B-PHDSS PHDR-10VS Reel : SPHD-002T-P0.5
Loose : BPHD-001T-P0.5J.S.T.CN2
CN3 S8B-PHDSS PHDR-08VS
6mm max
Chassis of PBA series
Chassis of customer system
Mounting Screw
CBA
Normal mounting
PBA/PBW-33
Terminal Blocks
Assembling and Installation Method
PBA∙PBW-series
June 25, 2020
¿ PBA10F, PBA15F, PBW15F, PBA30F, PBW30F Input voltage Derating Curve
¿ PBA10F, PBA15F, PBW15F, PBA30F, PBW30F, PBA50F, PBW50F, PBA75F, PBA100F, PBA150F Ambient temperature derating curve
¿ PBA300F, PBA600F, PBA1000F, PBA1500F, PBA1500T Ambient temperature derating curve
¡In the hatched area, the specification of Ripple, Ripple Noise is different from other area.¡ The ambient temperature should be measured 5 to 10 cm away from the power supply so that it won’t be influenced by the heat from the
power supply. Please consult us for more details.¡Make sure the temperature at point A is less than the temperatures shown in Instruction Manual 4.
¡In the hatched area, the specification of Ripple, Ripple Noise is different from other area.¡Derating curve depending on an ambient temperature (temperature of air sucked in for a cooling purpose) is shown above.
¿ PBA1500F Input voltage Derating Curve
Ambient temperature[C]
Load
fact
or
[%]
80
70
80
90
100
30
40
50
60
70
71C
010
20
30 40 50 60- 20 - 10 200 10
[AC V]
[%]100
80
85 90
Load
[AC V]
[%]100
80
85 95
Load
at AC100V
-10
706050403020
706050403020807060504030 [20] [30] [40] [50] [60] [70]
[10] [20] [30] [40] [50] [60][10] [20] [30] [40] [50] [60]
2
1
2Forced air (0.5m3 / min)1Convection
80
100
60
40
20
020100
Load
fact
or[%
]
ABC
Ambient temperature [C] Inside [ ]is with case cover
PBA/PBW-34
Derating
PBA∙PBW-series
June 25, 2020
PBA/PBW-35
◆ It is neccessary to read the “Instruction Manual” and “Before using our product” before you use our product.
Instruction Manual https://en.cosel.co.jp/product/powersupply/PBA/ Instruction Manual https://en.cosel.co.jp/product/powersupply/PBW/ Before using our product https://en.cosel.co.jp/technical/caution/index.html
Instruction Manual
NOTICEPBWPBA
*1 Refer to Series/Parallel Operation of Instruction Manual.* The value of input current is at ACIN 100V and rated load, ACIN 200V 3f and rated load in PBA1500T.
input fuseRated
Model frequencySwitching
Circuit method[A]
currentInput operation availability
Series/Parallel
Paralleloperation
PCB/PatternInrush
protectioncircuit
current
Material Doublesidedsided
Single Seriesoperation[kHz]
SCR FR-4
Yes
Thermistor
CEM-3
SCR FR-4
Yes
Yes
SCR
SCR
FR-4
FR-4
Thermistor
Thermistor
Thermistor
CEM-3
CEM-3
CEM-3
*1
*1
*1
*1
100
130
100
100
130
60 - 550
100
100
200
60 - 550
130
130
280
330
230
330
120
60 - 550
60 - 550
120
120
60 - 550
130
0.7
0.7
0.4
19
13
8.2
4.1
2.0
1.3
1.0
0.7
0.7
0.3
0.4
Thermistor
Thermistor
Thermistor
Thermistor
Thermistor
CEM-3
CEM-3
CEM-3
CEM-3
CEM-3
CEM-3
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes Yes
Yes
Yes
Yes
Yes
Yes
Yes
*1
1*
1*
1*
1*
Yes
PBA50F
PBW50F
PBW30F
PBA300F
PBA1000F
PBA1500F
PBW15F
PBA600F
PBA100F
PBA150F
PBA75F
PBA10F
PBA15F
PBA30F
LF
Basic Characteristics Data
250V 4A
250V 2A
250V 30A
250V 15A
250V 10A
250V 3.15A
250V 2A
Yes
Yes
1*
Active filter
Forward converter
Active filter
Forward converter
Active filter
Forward converter
Active filter
Forward converter
Active filter
Forward converter
Active filter
Forward converter
Active filter
Forward converter
Active filter
Forward converter
SCR FR-4130
2006 Yes YesPBA1500T 250V 16A Yes
Active filter
Forward converter
Forward converter
Active filter
Flyback converter
Flyback converter
Flyback converter
Flyback converter
Flyback converter
250V 2.5A
250V 3.15A
250V 2.5A
250V 3.15A
Basic Characteristics Data
PBA∙PBW-series
June 25, 2020