prefarbrication partner
TRANSCRIPT
PRE-CONSTRUCTION
Information Required
• Schematic drawing• Layout drawing• Technical datasheets
3D Design
• Full 3D model in Revit• Drawing layout “For Approval”
Advanced Bill of Material
• Early stage Bill of Quantities• Avoid delivery problems
• Estimation pricing package
Pre-Fabrication Options
• Loose Cut Lengths
DESIGN BID
Refrigerant
lbs (kg) Total Weight
(inc. Refrigerant) lbs (kg) Water Volume gal (l) Center of Gravity ins (mm)
Evap Cond X Y Z
Operating 635
(288)
11806 (5355)
61 (233)
56 (213)
50 (1278)
37 (945)
20 (510)
Shipping 10823 (4909)
- (-)
- (-)
50 (1267)
37 (943)
21 (533)
4. 2.5 in. (64 mm) diameter lifting holes are provided. See installation manual for lifting instructions. 5. All water connections are given in standard U.S. pipe sizes. Standard connections are suitable for welding or grooved couplings. 6. Vibration isolator pads are provided for field installation (0.25 in (6 mm) thick when loaded). 7. If main power wiring is brought up through the floor, this wiring must be outside the envelope of the unit. 8. The shipping skid adds 4 in. (105 mm) to the overall unit height. 9. Dimensions shown are for units with standard 150 psi (1034 kPa) design water side pressure. Check factory for unit dimensions with higher pressures. 1. 1 in. (25 mm) FPT evaporator and condenser relief valves must be piped per ANSI/ASHRAE 15.
2. At a minimum, length of tube sheet to tube sheet dimensions is required at either end for tube removal, 36 in. (914 mm) is required at other end and each side and top for service. 3. Final connections must allow for 0.5 in. (12.7 mm) manufacturing tolerance.
Product Drawing Unit Tag: Centrif 004 Sales Office: McQuay UK Operations Product: Water Cooled Centrifugal Chiller Project Name: Selfridges Sales Engineer: James Henley Model: WSC087M/E2609-2RB/C2209-2RB Date: 23/02/2015 Ver/Rev: Sheet: 1 of 5 Scale: NTS Tolerance: +/- 1.0” Dwg Units: in (mm) WSC087MAU47GYYLBE2609BE2RBC40446CCYAC2209CLYY2RBYYYC40965CCYYYYAA134064EY2LEYYAVLWYYYYY0534YM2B1YAXS31AB0502YPYYYYM0AYW000000000000JDNNNN No change to this drawing may be made unless approved in writing by McQuay UK Ltd. Purchaser must determine that the equipment is fit and sufficient for the job specifications
Product Drawing Unit Tag: Centrif 004 Sales Office: McQuay UK Operations Product: Water Cooled Centrifugal Chiller Project Name: Selfridges Sales Engineer: James Henley Model: WSC087M/E2609-2RB/C2209-2RB Date: 23/02/2015 Ver/Rev: Sheet: 2 of 5 Scale: NTS Tolerance: +/- 1.0” Dwg Units: in (mm) WSC087MAU47GYYLBE2609BE2RBC40446CCYAC2209CLYY2RBYYYC40965CCYYYYAA134064EY2LEYYAVLWYYYYY0534YM2B1YAXS31AB0502YPYYYYM0AYW000000000000JDNNNN No change to this drawing may be made unless approved in writing by McQuay UK Ltd. Purchaser must determine that the equipment is fit and sufficient for the job specifications
victaulic.com 06.23 7470 Rev C Updated 11/2015 © 2015 Victaulic Company. All rights reserved.
ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT.
2 - 12"/50 - 300 mm
1.0 PRODUCT DESCRIPTIONAvailable Sizes• 2 – 12"/50 – 300 mmPipe Material
• Carbon steel, Stainless steelMaximum Working Pressure• Accommodates pressures ranging from full vacuum (29.9 in Hg/760 mm Hg) up to 750 psi/5171 kPa.
• Working pressure dependent on material, wall thickness and size of pipe.
Operating Temperature• Dependent on gasket selection from section 3.0.Function• Joins carbon steel and/or stainless steel pipe.• Provides a rigid pipe joint designed to restrict axial or angular movement.
Pipe Preparation• Cut or roll grooved in accordance with Submittal 25.01: Victaulic Standard Groove Specifications.
Codes and Requirements• Hanger support spacing corresponds to ASME B31.1 Power Piping Code and ASME B31.9 Building Services
Piping Code. 2.0 CERTIFICATION/LISTINGS
NOTES• See Submittal 10.01: Victaulic Products for Fire Protection Piping Systems - Regulatory Approval Reference Guide for details.
• See Submittal 02.06: Victaulic Potable Water Approvals ANSI/NSF for potable water approvals if applicable.
Victaulic® QuickVic™ Rigid CouplingStyle 107N
06.23
1
System No.LocationSubmitted By
Date Spec SectionParagraphApproved
Date
Rev :
Checked by :
Drawn by : Date :
Drawing number :
All Victaulic drawings and piping engineering submittals will be based on information furnished tous and is provided solely as an aid to procurement and installation. The Victaulic Company is not
responsible for design by engineer of record, erection, or operation. Liability of Victaulic Company withreference to descriptions, lengths, locations, dimensions, or any other data shown herein is limited to the
amount charged by Victaulic Company for producing the drawing in question. In the event of an order,Victaulic products must be used in accordance with published specifications and Victaulic literature.
NOTE: Contractor to field verify all equipment configurations, nozzle locating dimensions andelevations for conformance to Victaulic layout drawing(s) PRIOR TO CUTTING PIPE. Please notifyVictaulic Construction Piping Services Division for recommendations regarding any deviations.
Date :
Sheet :
SELFRIDGES & Co
Chiller RoomTotal - Isometric Views
15-76209 _ 05 _ Total 2-2
L. Luypaert
P. Janssens
REV 0
18/06/2015
18/06/2015
CD-Total2-2
Total isometric view
Detail secondarychilled water pumps
Detail condenserwater pumps
Detail Primary chilledwater pumps
Detail chillerconnections
Victaulic check valve
Victaulic butterfly valve
Non - Victaulicactuated valve
Victaulic wye strainer
Victaulic check valve
Victaulic butterfly
valve
Victaulic wye
strainer
Victaulic butterfly
valve
Victaulic check valve
Victaulic butterfly
valve
Victaulic wye
strainer
Victaulic butterfly
valve
Victaulic wye
strainer
Victaulic butterfly
valve
Victaulic check valve
CH - 01
CH - 02
CH - 03
CH - 04
PP - 01
PP - 02
PP - 03
PP - 04
CP - 01
CP - 02
CP - 03
CP - 04
ADS - 01
SP - 06/07
SP - 01
SP - 05
SP - 02
SP - 04
SP - 03
Heat meters
Heat meter
No. Description Issued by Date
1 Revision 1 Date 1
Info Customer :
Schematic drawingLayout drawing
Technical Datasheets
ABOM :
Early stage BOQAvoid delivery problems
3D Design + Drawings for approval :
Full 3D model in RevitDrawing layout “ For Approval “
Pre-Fabrication service:
Increase productivity on site
Construction BOM + Cut lengths
BOM’s/ Cut lengths by area for ordering/pre-fabrication purpose
Area 1
Project meeting
Reality check structural & civil
situation
Victaulic Inspection Service
M to M - Metal to MetalTR - Torque requirement
Positive - Positive Offset rigid couplings
Fabrication Service Explanation - REV015/12/2015
Victaulic Fabrication Cell
Pre cut pipesVicSticks: Pre installed fittings
Cut Lengths
• Fabrication Spools
• Skids / Modules
Fab Spools
Prefabrication
CONTRACTOR DELIVERY
CONSTRUCTION
3D Drawings for Approval Victaulic Fabrication Spools
• Pre-cut pipes• Pre-installed fittings & valves
Skids / Modules
Info Customer :
Schematic drawingLayout drawing
Technical Datasheets
ABOM :
Early stage BOQAvoid delivery problems
3D Design + Drawings for approval :
Full 3D model in RevitDrawing layout “ For Approval “
Pre-Fabrication service:
Increase productivity on site
Construction BOM + Cut lengths
BOM’s/ Cut lengths by area for ordering/pre-fabrication purpose
Area 1
Project meeting
Reality check structural & civil
situation
Victaulic Inspection Service
M to M - Metal to MetalTR - Torque requirement
Positive - Positive Offset rigid couplings
Fabrication Service Explanation - REV015/12/2015
Victaulic Fabrication Cell
Pre cut pipesVicSticks: Pre installed fittings
Info Customer :
Schematic drawingLayout drawing
Technical Datasheets
ABOM :
Early stage BOQAvoid delivery problems
3D Design + Drawings for approval :
Full 3D model in RevitDrawing layout “ For Approval “
Pre-Fabrication service:
Increase productivity on site
Construction BOM + Cut lengths
BOM’s/ Cut lengths by area for ordering/pre-fabrication purpose
Area 1
Project meeting
Reality check structural & civil
situation
Victaulic Inspection Service
M to M - Metal to MetalTR - Torque requirement
Positive - Positive Offset rigid couplings
Fabrication Service Explanation - REV015/12/2015
Victaulic Fabrication Cell
Pre cut pipesVicSticks: Pre installed fittings
Info Customer :
Schematic drawingLayout drawing
Technical Datasheets
ABOM :
Early stage BOQAvoid delivery problems
3D Design + Drawings for approval :
Full 3D model in RevitDrawing layout “ For Approval “
Pre-Fabrication service:
Increase productivity on site
Construction BOM + Cut lengths
BOM’s/ Cut lengths by area for ordering/pre-fabrication purpose
Area 1
Project meeting
Reality check structural & civil
situation
Victaulic Inspection Service
M to M - Metal to MetalTR - Torque requirement
Positive - Positive Offset rigid couplings
Fabrication Service Explanation - REV015/12/2015
Victaulic Fabrication Cell
Pre cut pipesVicSticks: Pre installed fittings
Info Customer :
Schematic drawingLayout drawing
Technical Datasheets
ABOM :
Early stage BOQAvoid delivery problems
3D Design + Drawings for approval :
Full 3D model in RevitDrawing layout “ For Approval “
Pre-Fabrication service:
Increase productivity on site
Construction BOM + Cut lengths
BOM’s/ Cut lengths by area for ordering/pre-fabrication purpose
Area 1
Project meeting
Reality check structural & civil
situation
Victaulic Inspection Service
M to M - Metal to MetalTR - Torque requirement
Positive - Positive Offset rigid couplings
Fabrication Service Explanation - REV015/12/2015
Victaulic Fabrication Cell
Pre cut pipesVicSticks: Pre installed fittings
Info Customer :
Schematic drawingLayout drawing
Technical Datasheets
ABOM :
Early stage BOQAvoid delivery problems
3D Design + Drawings for approval :
Full 3D model in RevitDrawing layout “ For Approval “
Pre-Fabrication service:
Increase productivity on site
Construction BOM + Cut lengths
BOM’s/ Cut lengths by area for ordering/pre-fabrication purpose
Area 1
Project meeting
Reality check structural & civil
situation
Victaulic Inspection Service
M to M - Metal to MetalTR - Torque requirement
Positive - Positive Offset rigid couplings
Fabrication Service Explanation - REV015/12/2015
Victaulic Fabrication Cell
Pre cut pipesVicSticks: Pre installed fittings
• BOMs / Cut lengths by area for ordering / pre-fabrication purpose
Koelmachine 2
Koelmachine 1
TSA
Koeltoren 1
Koeltoren 2
1880
133
44
1503
419
578
513
584
943
1405
798
330
286
367 702
285
1292
375
608 522
296
13
B
845
1600
1600
895
1600
2000
680 2400 680
4940
3760
Rev :
Checked by :
Drawn by : Date :
Drawing number :
All Victaulic drawings and piping engineering submittals will be based on information furnished to usand is provided solely as an aid to procurement and installation. The Victaulic Company is not responsible
for design by engineer of record, erection, or operation. Liability of Victaulic Company with reference todescriptions, lengths, locations, dimensions, or any other data shown herein is limited to the amount
charged by Victaulic Company for producing the drawing in question. In the event of an order, Victaulicproducts must be used in accordance with published specifications and Victaulic literature.
NOTE: Contractor to field verify all equipment configurations, nozzle locating dimensions andelevations for conformance to Victaulic layout drawing(s) PRIOR TO CUTTING PIPE. Please notify
Victaulic Construction Piping Services Division for recommendations regarding any deviations.
Date :
Sheet :
St.60 Bodem
St.41 Flens Adapter Nippel
St.741 Flens Adapter
St.716H Terugslagklep
St.732 Y - Filter
St.761 MS Vlinderafsluiter Hendel
St.761 MS Vlinderafsluiter Tandwielkast
St.10 Bocht 90°
St.11 Bocht 45°
St.20 T - Stuk
St.25 Reduceer T - Stuk
St.50 Concentrisch Verloop
St.107 / 07 Rigide Koppeling
St.177 / 77 Flexibele Koppeling
Victaulic product legende :
WillemswerfRotterdam
Techniekruimte Koeling( Isometrisch aanzichten )
15 - 76554 _ 02 _ MP01
M. Filek
P. Janssens
REV 0
15 / 01 / 2016
F
15 / 01 / 2016
A0 - MP01St.7340 Meetflens (Oventrop)
DETAIL VERDELER KOELTORENS
DETAIL KOELMACHINE 1
DETAIL POMPEN
DETAIL TSA DETAIL KOELMACHINE 2
DETAIL KOELTORENS OP STAALCONSTRUCTIE
Gekoeld water aanvoer
Gekoeld water retour
Condenser wateraanvoer
Condenser water Retour
No. Description Issued by Date
Com pany F lam co b.v.Type F lam c o Clean F400c apa city 7 31 ltro rder_code 2 8198m ax. pressure 1 0 bard iam eter 800w idth 1220h eight 1810c onnec tion D N400
R
S
T
Q
293031Rev :
Checked by :
Drawn by : Date :
Drawing number :
Date :
Sheet :
SELFRIDGES & Co
Chiller roomBag & Tag area 1
Bag & Tag area 1 - Chillers
CD - BT1
18/06/2015
18/06/2015
REV 0
P. Janssens
L. Luypaert
All Victaulic drawings and piping engineering submittals will bebased on information furnished to us and is provided solely as an aid to
procurement and installation. The Victaulic Company is not responsible fordesign by engineer of record, erection, or operation. Liability of Victaulic
Company with reference to descriptions, lengths, locations, dimensions, orany other data shown herein is limited to the amount charged by VictaulicCompany for producing the drawing in question. In the event of an order,
Victaulic products must be used in accordance with publishedspecifications and Victaulic literature.
NOTE: Contractor to field verify all equipment configurations,nozzle locating dimensions and elevations for conformance to Victauliclayout drawing(s) PRIOR TO CUTTING PIPE. Please notify VictaulicConstruction Piping Services Division for recommendations regardingany deviations.
Issued by DateNo. Description
BAG & TAGAREA 1
-CHILLERS
CONTACT INFORMATIONUnits B1 & B2, SG1 Industrial ParkCockerell CloseGunnels Wood RoadStevenageHertfordshire, UKSG 1 2NB44 1438 310 [email protected]
WHO WE ARE VICTAULICSince 1919, Victaulic has been world’s leading producer of grooved mechanical couplings and pipe-joining systems. Used in the most demanding markets, Victaulic innovative piping technologies put people to work faster while increasing safety, ensuring reliability and maximizing efficiency. The company has 15 major manufacturing facilities, 28 branches worldwide and over 3,600 employees who speak 43 languages across the globe. With more than 1900 active global patents, Victaulic solutions are at work in 115 countries across diverse business lines including oil and gas, chemical, mining, power generation, water and wastewater treatment, military and marine, as well as commercial building and fire protection. Visit www.victaulic.com and follow us on LinkedIn, Facebook, Twitter, and YouTube.
VICTAULIC