  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    1/37

    ..................................................................................................................................... 2 ....................................... 4 ...................................................... 7

    ............................................................................ 8 ............................................................................. 9

    ......................................................................................... 9- ................................................................... 10 ............................................. 11

    ......................................................... 11 .......................... 14

    .................................................. 14

    ........................................................................................... 17 ....................................................................................... 17 .................................................................................... 17 ..................................................................... 18 .......................................................................... 18

    .......................................................................... 19 .......................................................................................... 23

    ........................................................................................... 24

    ...................................... 26 ..................... 27............................................................................................................................ 36......................................................................................................................... 37

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    2/37

    2

    200

    , .

    , .

    . .

    ,

    .

    .

    35% .

    ,

    .

    17. 2008. ,

    .

    ,

    , , , , , .

    , ,

    .

    ,

    . ,

    . ,

    .

    .

    (,

    ) ,

    , .

    , :

    , , .

    , .

    , , ,

    .

    .

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    3/37

    3

    . ( ),

    ( ). ,

    , ,

    . ,

    , .

    ,

    ,

    .

    1.

    .

    , ,

    32,8%, .

    1.

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    4/37

    4

    Thomson, ,

    . ( ) 1891.

    Carnot- .

    ,

    .

    1940. Westinghouse ,

    , 770 W

    2,37, + 5 C.

    .

    , ,

    .

    2. Westinghouse 1940.

    , 1938. ,

    , . 190 kW, R12 . 1939.

    1,5 MW (R717) , , , .

    Sulzer Escher Wyss.

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    5/37

    5

    3.

    ()

    ()

    5. HWT

    , C , OS , LC , , LR Limmat

    4.

    ,

    ()

    ()

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    6/37

    6

    .

    1954. , . 240 kW, SO2(R764)

    . 3 4. ,1959. ,

    , Festival Hali . ,

    . 2,3 2,6 MW,

    R12 2,5 3. 82 C,

    0 C.

    , . 1954.

    ,

    .

    1,2 kW, 0,7 kW.

    , .

    . , 2 MW,

    1 800 .

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    7/37

    7

    , ()

    . :

    1. ( ): , : , ,

    , .

    2. ( ): , . , , .

    6. , ,

    .

    , , (, - ).

    . , ( ), ,

    ( ).

    , ,

    -, , (

    ), , , .

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    8/37

    8

    , , (. ), .

    kW MW.

    , (.

    ).

    , :

    1. (. )

    2. 3. (.

    )

    4. ( )5. ( ).

    .

    . , , ,

    .

    COP (Coefficient of Performance).

    , , , ,

    .

    ,

    .

    .

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    9/37

    9

    , :

    1. ,

    ,

    2. - ,

    .

    . (. , , .)

    (, ),

    ( ), .

    . ,

    ,

    .

    7. . : 1 , 2 , 3 , 4 , 5

    , 6 , 7 , 8 . - , 1 8

    , , , ,

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    10/37

    10

    -

    , -

    .

    , . ,

    .

    ( )

    . ,

    , . (

    ) ,

    (. ) .

    ,

    , . ,

    . ,

    . , ,

    .

    .

    8.

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    11/37

    11

    .

    .

    , .

    ,

    ,

    ( ) .

    ( )

    -5 C.

    , ,

    :

    ,

    (. ).

    500 m2 ,

    ( )

    .

    9. . 1 , 2 , 3 , 4 . : 1,0 m 1,4 m , b 1,5 m , c1,5 m , , d0,5 m , e1,0 m , f3,0 m

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    12/37

    12

    (, .) 1,2 1,5 m (20 cm ), ,

    0,3 0,7 m, m2

    1,5 2 m .

    5 15 C.

    , ,

    .

    20 40 W/m2 .

    () 50 C,

    (.

    ). 9. .

    ().

    , , , .

    30 60, 100 m,

    ,

    (, , ).

    , , :

    U , ,

    ,

    ,

    .

    10. . 1 , 2 , 3 , 4 () , 5 U (2

    ), , 6 , 150 cm, 10 cm.

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    13/37

    13

    : / 1,0 m ,

    , b 2,0 m,

    c 115 220 mm( ,

    ) , , d , 6

    20 m, 170 mm, e 3,0 m

    , 50 100 W/ m

    , () ,

    .

    , ,

    .

    . () 15 m. 10 C

    , , .

    .

    (.

    ).

    11. , . 1

    , 2 , 3 , 5 (100 120 m , ), 6 , 7 , 8 , 9 , 10 , 11 ,

    12,13

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    14/37

    14

    , , ,

    ( ) .

    ( ,

    ) ,

    .

    . , ,

    +4 C. ,

    , ,

    ,

    -

    , . ,

    . .

    .

    ,

    .

    -,

    () .

    /

    .

    .

    , ,

    . (),

    . +5 C

    . ,

    -20 C,

    28 C.

    ,

    - , ,

    . , ""

    +5 C,

    .

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    15/37

    15

    12. , . 1 , 2- , 3 , 5 , 5 , 6 -

    1.

    , , , .

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    16/37

    16

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    17/37

    17

    :

    .

    .

    13.

    .

    .

    .

    15%.

    14.

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    18/37

    18

    .

    (.

    0 C),

    ( . ).

    .

    60 70%

    ( ).

    15.

    .

    .

    .

    16.

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    19/37

    19

    ,

    , .

    , .

    17.

    .

    . , . ,

    . , ,

    .

    . ,

    .

    .

    , .

    , ,

    .

    , . .

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    20/37

    20

    :

    , ,

    . , .

    ,

    .

    . ,

    , , ,

    . ,

    .

    , .

    , .

    ,

    .

    , .

    ,

    , , ,

    ,

    .

    .

    , , , .

    /

    .

    20%

    .

    .

    , .

    .

    ,

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    21/37

    21

    , . , ,

    , , . ,

    , .

    , .

    . , , .

    ,

    , .

    ,

    . . ,

    . , (50%), (36%)

    (7%).

    ,

    ( ).

    , , .

    ,

    .

    .

    10 15 % ,

    ,

    5 K 10 K ,

    .

    , .

    . . 18

    , ,

    ( ). .

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    22/37

    22

    18.

    , ,

    .

    , ,

    , .

    .

    , ,

    ,

    . . 19

    210 . ,

    12C.

    19.

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    23/37

    23

    . , . 18, .

    , (. 19),

    . . 18 ,

    .

    , .

    , , .

    ,

    ( ), ,

    . . 20

    .

    ( ).

    20. ; 1 , 2 , 3 10 m, 4

    5

    2. .

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    24/37

    24

    2. . 21 . , .

    .

    21. ; 1 (), 2 , 3 , 4

    ( 2 21)

    ( 3)

    . ,

    ( 5)

    .

    ,

    .

    ,

    , .

    ,

    .

    , .

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    25/37

    25

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    26/37

    26

    . .

    . , ,

    ,

    .

    , , ,

    .

    , 90 C/70 C, ,

    .

    . , ,

    , .

    , . , .

    . ,

    ,

    . ,

    .

    .

    .

    ,

    ,

    .

    ,

    .

    , .

    , , ,

    .

    . , 0 C;

    ,

    .

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    27/37

    27

    , ,

    . 608 m2

    428 m2 . 2008.

    2009. Wienerberger

    POROTHERM. . PVC

    .

    Schiedel Duco

    . 22. 23.

    .

    22. POROTHERM 38

    23. ( )

    http://beodom.com/sr/partners/wienerbergerhttp://beodom.com/sr/partners/wienerbergerhttp://beodom.com/sr/partners/schiedelhttp://beodom.com/sr/partners/schiedelhttp://beodom.com/sr/partners/ducohttp://beodom.com/sr/partners/ducohttp://beodom.com/sr/partners/ducohttp://beodom.com/sr/partners/schiedelhttp://beodom.com/sr/partners/wienerbergerhttp://beodom.com/sr/partners/wienerberger
  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    28/37

    28

    , .

    , , . .

    5 Rehau Raugeo

    100 m. , Vaillant , GeoTHERM VWS 300/2.

    VPS 750 750 ().

    .

    .

    Rehau SOLECT .

    2 500 . 24.

    .

    24.

    .

    .

    , .

    http://beodom.com/sr/partners/rehauhttp://beodom.com/sr/partners/rehauhttp://beodom.com/sr/partners/vaillanthttp://beodom.com/sr/partners/rehauhttp://beodom.com/sr/partners/rehauhttp://beodom.com/sr/partners/rehauhttp://beodom.com/sr/partners/vaillanthttp://beodom.com/sr/partners/rehau
  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    29/37

    29

    (PE-Xa) ( C2H6O2 )

    . 25. Rehau Raugeo .

    25. Rehau RAUGEO: .

    .

    tungsten-carbide (widia) ,

    . ,

    .

    . 26. . 27. .

    26.

    http://beodom.com/sr/partners/rehauhttp://beodom.com/sr/partners/rehau
  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    30/37

    30

    27.

    28. , .

    28.

    , .

    . . ,

    .

    . ,

    . 50 .

    25 000 .

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    31/37

    31

    29.

    , 2,5 m

    . . 30.

    .

    30.

    , 18 m/kW,

    35 50 W/m. 0 C +20 C , .

    10 C. 31.

    .

    31.

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    32/37

    32

    Vaillant ,GeoTHERM VWS 300/2, 30 kW .

    - . ,

    .

    . VPS 750 750 .

    . ,

    .

    50 kW.

    .

    -3 C.

    . 32. ,

    33.

    .

    32.Vaillant GeoTHERM VWS 300/2

    33. Vaillant

    http://beodom.com/sr/partners/vaillanthttp://beodom.com/sr/partners/vaillant
  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    33/37

    33

    ( ) 0 C 35 C 30,5 kW.

    6,5 kW, 4,7. 5 C

    55 C, 31,5 kW.

    9,6 kW, 3,3. Vaillant GeoTHERM VWS 300/2 R 407C.

    5,99 kg.

    2,9 MPa , 3,2 MPa.

    scroll .

    Ester 4 l.

    62 C.

    4 000 . 2009.

    600 m2 16.409 , 13 .

    1,5 kW.

    2010. 1 360 . 34. 2010.

    .

    34. ,

    35. VR 90/2 .

    , . 35. 2008.

    8 C 10 C, 33C.

    30 kW 45 kW .

    8 C 35 kW

    .

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    34/37

    34

    35.

    36. .

    . ,

    . 2 808 kWh. 2 808 kWh

    .

    36.

    37.

    .

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    35/37

    35

    37.

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    36/37

    36

    .

    . ()

    , , , 26. 2009. (IRENA).

    .

    100 C ,

    , ,

    .

    , .

    .

    . ?

    . ,

    , .

  • 7/27/2019 Primena toplotnih pumpi u stambenim objektima

    37/37

    [1] , : , , , 2009.

    [2] Vaillant:

    [3] :http://beodom.com/sr/construction/amadeo/overview

    [4] Loren line:http://www.loren-line.rs/toplotne_pumpe.htm?gclid=CPKkhKul7rcCFdIPtAodaxsAqg

    http://beodom.com/sr/construction/amadeo/overviewhttp://beodom.com/sr/construction/amadeo/overviewhttp://www.loren-line.rs/toplotne_pumpe.htm?gclid=CPKkhKul7rcCFdIPtAodaxsAqghttp://www.loren-line.rs/toplotne_pumpe.htm?gclid=CPKkhKul7rcCFdIPtAodaxsAqghttp://www.loren-line.rs/toplotne_pumpe.htm?gclid=CPKkhKul7rcCFdIPtAodaxsAqghttp://beodom.com/sr/construction/amadeo/overview