process pressure - ac controls

20
141 Pressure Process Pressure Overview 142 VEGABAR series 10 144 VEGABAR series 50 148 Accessories 158

Upload: others

Post on 11-May-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Process Pressure - AC Controls

141

Pres

sure

Process PressureOverview 142

VEGABAR series 10 144

VEGABAR series 50 148

Accessories 158

Page 2: Process Pressure - AC Controls
Page 3: Process Pressure - AC Controls
Page 4: Process Pressure - AC Controls

144

1 2 3

151

mm

(595

")

23 m

m(0

91")

49,5

mm

(195

")

36 mm(1.42")

ø 38 mm(1.5")

½ NPT

M12 x 1

G ½G ½

25 m

m(0

98")

124

mm

(488

")

20 m

m(0

79")

45 mm(1.77")

132

mm

(520

")10

mm

(039

")25

mm

(098

")

Process Pressure – VEGABAR 14

1 Threaded version G½, manometer connection EN 837 with plug connection ISO 4400

2 Threaded version G½, inner G¼ with direct cable outlet

3 Threaded version ½ NPT, inner ¼ NPT with plug connection M12 x 1

VEGABAR 14 Process pressure transmitter with CERTEC® measuring cell Application area The VEGABAR 14 pressure transmitter can be used universally for measurement of gases and liquids. The small pressure transmitter offers maximum reliability and operational safety. The VEGABAR 14 is an economical solution for a number of applications in all industries. Advantages High plant availability through maximum overload and vacuum resistance of the

ceramic measuring cell Price-favourable version with small mounting dimensions Low costs for maintenance through wear-free ceramic measuring cell Technical data Measuring cell: CERTEC® Measuring range: -1 … +60 bar (-100 … +6000 kPa) Process fitting: thread from G½, ½ NPT Process temperature: -40 … +100 °C Deviation of characteristics: 0.3 %

Page 5: Process Pressure - AC Controls

145Process Pressure – VEGABAR 14

Approval.X without .................................................................................................................................................M Ship approval .....................................................................................................................................

Pressure / Measuring range1S rel. / 0...0.1 bar (0...10 kPa) ......................................................................................................1T rel. / 0...0.25 bar (0...25 kPa) ....................................................................................................1U rel. / 0...0.4 bar (0...40 kPa) ......................................................................................................1V rel. / 0...0.6 bar (0...60 kPa) ......................................................................................................1A rel. / 0...1 bar (0...100 kPa) .......................................................................................................1B rel. / 0...1.6 bar (0...160 kPa) ....................................................................................................1C rel. / 0...2.5 bar (0...250 kPa) ....................................................................................................1D rel. / 0...4 bar (0...400 kPa) .......................................................................................................1E rel. / 0...6 bar (0...600 kPa) .......................................................................................................1F rel. / 0...10 bar (0...1000 kPa) ...................................................................................................1G rel. / 0...16 bar (0...1600 kPa) ...................................................................................................1H rel. / 0...25 bar (0...2500 kPa) ...................................................................................................1I rel. / 0...40 bar (0...4000 kPa) ...................................................................................................

1J rel. / 0...60 bar (0...6000 kPa) ...................................................................................................3T rel. / -0.1...+0.1 bar (-10...+10 kPa) ...........................................................................................3U rel. / -0.2...+0.2 bar (-20...+20 kPa) ...........................................................................................3A rel. / -0.5...+0.5 bar (-50...+50 kPa) ...........................................................................................3B rel. / -1...+0.6 bar (-100...+60 kPa) ............................................................................................3W rel. / -1...+1 bar (-100...+100 kPa) .............................................................................................3C rel. / -1...+1.5 bar (-100...+150 kPa) ..........................................................................................3D rel. / -1...+3 bar (-100...+300 kPa) .............................................................................................3E rel. / -1...+5 bar (-100...+500 kPa) .............................................................................................3F rel. / -1...+9 bar (-100...+900 kPa) .............................................................................................3G rel. / -1...+15 bar (-100...+1500 kPa) .........................................................................................3H rel. / -1...+25 bar (-100...+2500 kPa) .........................................................................................3I rel. / -1...+40 bar (-100...+4000 kPa) .........................................................................................

3J rel. / -1...+60 bar (-100...+6000 kPa) .........................................................................................2A abs. / 0...1 bar (0..100kPa) ........................................................................................................2B abs. / 0...1.6 bar (0...160kPa) ....................................................................................................2C abs. / 0...2.5 bar (0...250kPa) ....................................................................................................2D abs. / 0...4 bar (0...400kPa) .......................................................................................................2E abs. / 0...6 bar (0...600kPa) .......................................................................................................2F abs. / 0...10 bar (0...1000kPa) ...................................................................................................2G abs. / 0...16 bar (0...1600kPa) ...................................................................................................2H abs. / 0...25 bar (0...2500kPa) ...................................................................................................2I abs. / 0...40 bar (0...4000kPa) ...................................................................................................

2J abs. / 0...60 bar (0...6000kPa) ...................................................................................................Electrical connection / ProtectionA1 4-pole plug connection ISO4400 PG9 / IP65 ....................................................................A2 4-pole plug connection hinged cover ISO4400 / IP 65 .....................................................C1 Direct cable outlet 5 m cable / IP 67 .................................................................................M1 Circular plug conn.,4-pole w.screwed plug M12x1 / IP65 .................................................M2 Plug connect.4-pol. M12x1 with 5m connection cable/IP65 .............................................

Process fitting / MaterialGN Thread ½NPT, inner ¼NPT(ASME B1.20.1) PN60 / 316L ......................................TA Varivent N50-40 PN25 / 316L .................................................................................GB Thread M20x1.5(EN837)manometer PN60 / 316L .................................................GF Thread 1½NPT (ASME B1.20.1) PN60 / 316L ........................................................

Seal measuring cell / Process temperature1 FKM (VP2/A) / -20...100°C ................................................................................3 EPDM (A+P 75.5/KW75F) / -40...100°C ...........................................................

BAR14

Pres

sure

Page 6: Process Pressure - AC Controls

146

1 2 3

G1 G ½

SW 41 mm(1.61")

G1

SW 41 mm(1.61")

SW 27 mm(1.06")

28 m

m(1

10")

20,5

mm

(081

")

~135

mm

(532

")

~90

mm

(354

")

ø 27mm (1.06")

20,5

mm

(081

")

~78

mm

(307

")

65 m

m(2

56")

max. 90 mm (3.54")

ø 61 mm(2.40")

Process Pressure – VEGABAR 17

1 Threaded version G1, hygienic with angle plug connection DIN 43650

2 Threaded version G1, front-flush with plug connection M12x1

3 Threaded version G½, front-flush with terminal housing

VEGABAR 17 Process pressure transmitter with metallic measuring cell Application area The VEGABAR 17 is a universal pressure transmitter for measurement of gases, vapours and liquids. The VEGABAR 17 is an economical solution for a number of applications in all industries. Advantages Price-favourable version with smallest mounting dimensions Universal use through completely welded measuring cell High chemical resistance through high quality diaphragm materials Technical data Measuring cell: piezoresistive/thin film strain gauge Measuring range: -1 … +1000 bar (-100 … +100000 kPa) Process fitting: thread from G½, ½ NPT Process temperature: -40 … +150 °C Deviation in characteristics: 0.5 %

Page 7: Process Pressure - AC Controls

147Process Pressure – VEGABAR 17

ApprovalZ without .........................................................................................................................................................................A ATEX II 1/2G, 2G Ex ia IIC T6 .....................................................................................................................................D ATEX II 1/2G, 2G Ex ia IIC T6+ATEX II 1/2D IP6X T+M1 ............................................................................................S ATEX II 1/2G, Ex ia IIC T6 + Ship approval .................................................................................................................

Process fitting / MaterialGDX G½B, manometer connection / 316Ti ...............................................................................................................GBX G¼B manometer connection / 316Ti ................................................................................................................NBX Thread ¼NPT / 316Ti .......................................................................................................................................NDX Thread ½NPT / 316Ti .......................................................................................................................................

PressureB Gauge pressure ..........................................................................................................................................S Absolute pressure .......................................................................................................................................

Measuring rangeLA -0.1...0 bar (-10...0 kPa) .....................................................................................................................KA -0.16...0 bar (-16...0 kPa) ...................................................................................................................GA -0.25...0 bar (-25...0 kPa) ...................................................................................................................FA -0.4...0 bar (-40...0 kPa) .....................................................................................................................DA -0.6...0 bar (-60...0 kPa) .....................................................................................................................CA -1...0 bar (-100...0 kPa) ......................................................................................................................CH -1...3 bar (-100...300 kPa) ..................................................................................................................AL 0...0.1 bar (0...10 kPa) .......................................................................................................................AM 0...0.16 bar (0...16 kPa) .....................................................................................................................AN 0...0.25 bar (0...25 kPa) .....................................................................................................................BB 0...0.4 bar (0...40 kPa) .......................................................................................................................BC 0...0.6 bar (0...60 kPa) .......................................................................................................................BD 0...1 bar (0...100 kPa) ........................................................................................................................BE 0...1.6 bar (0...160 kPa) .....................................................................................................................BF 0...2.5 bar (0...250 kPa) .....................................................................................................................BG 0...4 bar (0...400 kPa) ........................................................................................................................BH 0...6 bar (0...600 kPa) ........................................................................................................................BI 0...10 bar (0...1000 kPa) .....................................................................................................................

BK 0...16 bar (0...1600 kPa) .....................................................................................................................BL 0...25 bar (0...2500 kPa) .....................................................................................................................BM 0...40 bar (0...4000 kPa) .....................................................................................................................BN 0...60 bar (0...6000 kPa) .....................................................................................................................BO 0...100 bar (0...10000 kPa) .................................................................................................................BP 0...160 bar (0...16000 kPa) .................................................................................................................BQ 0...250 bar (0...25000 kPa) .................................................................................................................BS 0...400 bar (0...40000 kPa) .................................................................................................................BT 0...600 bar (0...60000 kPa) .................................................................................................................BU 0...1000 bar (0...100000 kPa) .............................................................................................................

Electrical connection / ProtectionA4 Angle plug connector DIN43650 / IP65 ......................................................................................M4 Circular plug connector, 4-pole w. screwed plug M12x1 ............................................................DL Cable outlet PUR / IP 67 ...........................................................................................................EM Cable outlet PUR / IP 68 (0.5 bar) .............................................................................................

Cable lengthZ without ................................................................................................................................C 1.5 m ...................................................................................................................................E 3 m .....................................................................................................................................G 5 m .....................................................................................................................................I 10 m ....................................................................................................................................

Features / Cleaning procedureZ without ...........................................................................................................................

Temperature rangeA -30...100°C (standard product temperature) ............................................................E -20...60°C (product temperature) .............................................................................U -20...80°C (ambient temperature with EEx ia) ..........................................................

Certificate / StandardZ No ......................................................................................................................1 Inspection certificate 3.1/EN10204 (material) .....................................................

BR17.

Pres

sure

Page 8: Process Pressure - AC Controls

148

108

mm

(425

")

94 m

m (3

7")

D

1 2

Process Pressure – VEGABAR 51

1 Flange version +150 °C

2 Version with tube isolating diaphragm +150 °C

VEGABAR 51 Pressure transmitter with chemical seal Application area The VEGABAR 51 is a pressure transmitter with chemical seal for pressure and level measurement. The chemical seal systems of VEGABAR 51 adapted to the process ensure a reliable measurement even with highly corrosive and hot products. Advantages Simple adaptation, due to individual configuration Reliable measurement up to temperatures of 400 °C Reliable measurement independent of foam generation and tank installations Technical data Measuring cell: chemical seal system Measuring range: -1 … +400 bar (-100 … +40000 kPa) Process fitting: flanges from DN 25, 1" Process temperature: -40 … +400 °C Deviation in characteristics: 0.2 % SIL qualification: up to SIL2

Page 9: Process Pressure - AC Controls

149Process Pressure – VEGABAR 51

ApprovalUX FM(NI)CL I,DIV2,GP ABCD (DIP)CL II,III,DIV1,GP EFG .....................................................................................UF FM(IS)CL I,II,III, DIV 1,GP ABCDEF ....................................................................................................................UG FM(XP-IS) CLI,II,III, DIV 1, GP ABCDEFG ...........................................................................................................KX CSA(NI)CL I,DIV 2,GP ABCD(DIP)CL II,III,DIV1,GP EFG ...................................................................................KF CSA(IS)CL I,II,III, DIV1, GP ABCDEFG ...............................................................................................................KG CSA(XP-IS) CLI,II,III, DIV 1, GP ABCDEFG ........................................................................................................

Process fitting / MaterialF1 Flange 1" 150 b RF, ANSI B16.5 / 316L ......................................................................................................F5 Flange 2" 150 b RF, ANSI B16.5 / 316L ......................................................................................................F7 Flange 2" 150 b RF, ANSI w. extension 2"/ø1.9" / 316L ..............................................................................DA Flange 2"150lb RF,ANSI w. extension 4",ø1.9"/316L ..................................................................................DB Flange 2"150lb RF,ANSI w. extension 6",ø1.9"/316L ..................................................................................F2 Flange 2"300lb RF,ANSI B16.5/316L ..........................................................................................................FS Flange 3" 150 b RF, ANSI B16.5 / 316L ......................................................................................................FQ Flange 3" 150 b RF, ANSI w.extension 6"/ø2.9" / 316L ...............................................................................FT Flange 3"300lb RF,ANSI B16.5/316L ..........................................................................................................

HG Flange 3" 300 b RF, ANSI w.extension 2"/ø2,9" / 316L ...............................................................................Isolating liquid / TemperatureA Silicone oil KN2.2 /-40...150°C (Pabs <1bar-40...150°C) ......................................................................C Silic.oil KN2.2+cool./ -40..200°C(Pabs <1bar-40..150°C) .....................................................................G HT oil KN3.2+cool. / -10...300°C(Pabs<1bar-10..200°C) ......................................................................H HT oil KN3.2+capil.1m/ -10..400°C(Pabs<1bar-10...200°C) .................................................................

Material diaphragm1 316L ...............................................................................................................................................2 Hastelloy C276 ...............................................................................................................................

Pressure / Measuring rangeC rel. / 0...0.4 bar (0...40 kPa) .....................................................................................................D rel. / 0...1 bar (0...100 kPa) ......................................................................................................E rel. / 0...2.5 bar (0...250 kPa) ...................................................................................................F rel. / 0...5 bar (0...500 kPa) ......................................................................................................G rel. / 0...10 bar (0...1000 kPa) ..................................................................................................N rel. / 0...60 bar (0...6000 kPa) ..................................................................................................Q rel. / -1...1.5 bar (-100...150 kPa) .............................................................................................R rel. / -1...5 bar (-100...500 kPa) ................................................................................................S rel. / -1...10 bar (-100...1000 kPa) ............................................................................................V rel. / -1...60 bar (-100...6000 kPa) ............................................................................................1 abs. / 0...1 bar (0...100 kPa) ....................................................................................................2 abs. / 0...2.5 bar (0...250 kPa) .................................................................................................3 abs. / 0...5 bar (0...500 kPa) ....................................................................................................4 abs. / 0...10 bar (0...1000 kPa) ................................................................................................7 abs. / 0...60 bar (0...6000 kPa) ................................................................................................

ElectronicsZ 4 ... 20 mA .........................................................................................................................H 4...20mA/HART® ...............................................................................................................P Profibus PA ........................................................................................................................F Foundation Fieldbus ..........................................................................................................

Housing / ProtectionK Plastic / IP66/IP67 ......................................................................................................A Aluminium / IP66/IP67 ................................................................................................D Aluminium double chamber / IP66/IP67 ......................................................................

Cable entry / Cable gland / Plug connectionN ½NPT / without / without ......................................................................................

Indicating/adjustment module (PLICSCOM)X without ............................................................................................................A mounted .........................................................................................................

Vacuum serviceX without ......................................................................................................J with (with meas. ranges <0.5bar abs) .......................................................

Accuracy classS 0.20% .................................................................................................

BR51.

Pres

sure

Page 10: Process Pressure - AC Controls

150

1

2

3

SW 27 mm(1.06")

G ½

23 m

m(0

91")

73 m

m(2

87")

3 m

m(0

12")

ø 3 mm (0.12")

ø 6 mm (0.24")

SW 46 mm(1.81")

G1 ½

50 m

m(1

97")

50 m

m(1

97")

22 m

m(0

87")

ø 55 mm (2.17")

ø 40 mm (0.69")

Process Pressure – VEGABAR 52

1 Threaded version G½ (manometer connection EN 837)

2 Threaded version G1½

3 Flange version DN 50

VEGABAR 52 Pressure transmitter with CERTEC® measuring cell Application area The VEGABAR 52 pressure transmitter can be used universally for measurement of gases, vapours and liquids. Also substances such as sand can be easily measured through the abrasion-resistant ceramic measuring cell. The VEGABAR 52 offers maximum reliability and safety and can be used in all industries. Advantages High plant availability by maximum overload and vacuum resistance of the

ceramic measuring cell Measurement down to the last drop through smallest measuring ranges with high

reliability Low maintenance costs through wear-free ceramic measuring cell Technical data Measuring cell: CERTEC® Measuring range: -1 … +60 bar (-100 … +6000 kPa) Process fitting: thread from G½, ½ NPT flanges from DN 25, 1½" hygienic fittings Process temperature: -40 … +150 °C Deviation in characteristics: 0.2 %; 0.1 %; 0.075 % SIL qualification: up to SIL2

Page 11: Process Pressure - AC Controls

151Process Pressure – VEGABAR 52

ApprovalUX FM(NI)CL I,DIV2,GP ABCD (DIP)CL II,III,DIV1,GP EFG ................................................................................................UF FM(IS)CL I,II,III, DIV 1,GP ABCDEF ...............................................................................................................................UG FM(XP-IS) CLI,II,III, DIV 1, GP ABCDEFG .....................................................................................................................KX CSA(NI)CL I,DIV 2,GP ABCD(DIP)CL II,III,DIV1,GP EFG .............................................................................................KF CSA(IS)CL I,II,III, DIV1, GP ABCDEFG ..........................................................................................................................KG CSA(XP-IS) CLI,II,III, DIV 1, GP ABCDEFG ...................................................................................................................

Process fitting / MaterialGF Thread 1½NPT (ASME B1.20.1) PN60/316L ........................................................................................................GN Thread ½NPT, inner ¼NPT (ASME B1.20.1) PN160/316L ...................................................................................CC Clamp 1½" PN16(ø50.5mm) DIN32676,ISO2852 /316L .......................................................................................CA Clamp 2" PN16(ø64mm) DIN32676,ISO2852 /316L .............................................................................................CB Clamp 3" PN10(ø91.0mm) DIN32676,ISO2852 /316L ..........................................................................................GJ Thread ½NPT inner thread (ASME B1.20.1) PN60/316L ......................................................................................FQ Flange 1½"150lb RF,ANSI B16.5/316LZG2662 ....................................................................................................FH Flange 2" 150 b RF, ANSI B16.5 / 316L ................................................................................................................TT Flange with extension 2"150lb ZG3173,316L .......................................................................................................EH Flange 2"300lb RF, ANSI B16.5/316L ...................................................................................................................EI Flange 2"600lb RF,ANSI B16.5/316L ....................................................................................................................FI Flange 3" 150 b RF, ANSI B16.5 / 316L ................................................................................................................

TU Flange w. extension 3"150lb ZG3237,316L ..........................................................................................................FF Flange 3"300lb RF,ANSI B16.5/316L ....................................................................................................................TV Flange w. extension 3"300lb ZG3144,316L ..........................................................................................................FD Flange 3"600lb RF,ANSI B16.5/316L ....................................................................................................................T1 Flange w. extension 3"600lb ZG3144,316L ..........................................................................................................T3 Flange w.extension 3"900lb ZB3984,316L ...........................................................................................................EC Flange 4"150lb RF,ANSI B16.5/316L ....................................................................................................................TW Flange w. extension 4"150lb ZG2961,316L ...........................................................................................................EB Flange 4"300lb RF,ANSI B16.5/316L ....................................................................................................................T4 Flange w.extension 4"300lb ZG4002,316L ...........................................................................................................

Seal measuring cell / Process temperatureI EPDM - double (A+P 75.5/KW75F) / -40...+120°C .........................................................................................5 FFKM/FKM - double (Perlast G75S) / -15...+120°C .......................................................................................

Pressure / Measuring rangeA rel. / 0...1.5 psi .........................................................................................................................................B rel. / 0...3.0 psi .........................................................................................................................................C rel. / 0...5.0 psi .........................................................................................................................................P rel. / -14.5...0.0 psi ...................................................................................................................................Q rel. / -14.5...20.0 psi .................................................................................................................................R rel. / -14.5...60.0 psi .................................................................................................................................S rel. / -14.5...150.0 psi ...............................................................................................................................H rel. / -14.5...300.0 psi ...............................................................................................................................V rel. / -14.5...900.0 psi ...............................................................................................................................L rel. / -1.5...1.5 psi .....................................................................................................................................M rel. / -3.0...3.0 psi .....................................................................................................................................

ElectronicsZ 4 ... 20 mA .........................................................................................................................................H 4...20mA/HART® ...............................................................................................................................P Prof bus PA ........................................................................................................................................F Foundation Fieldbus ..........................................................................................................................

Housing / ProtectionK Plastic / IP66/IP67 ......................................................................................................................A Aluminium / IP66/IP67 ................................................................................................................D Aluminium double chamber / IP66/IP67 .....................................................................................8 StSt (electropolished) 316L / IP66/IP67 .....................................................................................

Cable entry / Cable gland / Plug connectionN ½NPT / without / without ......................................................................................................

Indicating/adjustment module (PLICSCOM)X without ...........................................................................................................................A mounted .........................................................................................................................

Accuracy classM 0.075 % ...................................................................................................................E 0.10% ......................................................................................................................S 0.20% ......................................................................................................................

BR52.

Pres

sure

Page 12: Process Pressure - AC Controls

152

1 2 3

G ½ 63 m

m(2

48")

65 m

m(2

56")

65 m

m(2

56")

20,5

mm

(081

")10

mm

(039

")

20,5

mm

(081

")10

mm

(039

")

ø 18 mm (0.71")

ø 30 mm (1.18")

G ½ G1

SW 41 mm(1.61")

SW 27 mm(1.06") 23

mm

(091

")

3 m

m(0

12") ø 3 mm

(0.12") ø 6 mm (0.24")

ø 40 mm (0.69")

Process Pressure – VEGABAR 53

1 Threaded version G½, manometer connection EN 837

2 Threaded version G½, front-flush

3 Threaded version G1, front-flush

VEGABAR 53 Pressure transmitter with metallic measuring cell Application area The VEGABAR 53 is a pressure transmitter for pressure measurement of gases, vapours and liquids.The VEGABAR 53 is the correct choice when small process fittings are required. Applications are found in all industries. Advantages Universal use through completely welded measuring cell High measurement precision through vacuum resistant version Maximum reliability and safety through proven technology Technical data Measuring cell: piezoresisitive/thin film strain gauge Measuring range: -1 … +1000 bar (-100 … +100000 kPa) Process fitting: thread from G½, ½ NPT flanges from DN 40 hygienic fittings Process temperature: -40 … +150 °C Deviation in characteristics: 0.2 %; 0.1 %; 0.075 % SIL qualification: up to SIL2

Page 13: Process Pressure - AC Controls

153Process Pressure – VEGABAR 53

ApprovalUX FM(NI)CL I,DIV2,GP ABCD (DIP)CL II,III,DIV1,GP EFG ....................................................................UF FM(IS)CL I,II,III, DIV 1,GP ABCDEF ...................................................................................................UG FM(XP-IS) CLI,II,III, DIV 1, GP ABCDEFG .........................................................................................KX CSA(NI)CL I,DIV 2,GP ABCD(DIP)CL II,III,DIV1,GP EFG .................................................................KF CSA(IS)CL I,II,III, DIV1, GP ABCDEFG ..............................................................................................KG CSA(XP-IS) CLI,II,III, DIV 1, GP ABCDEFG .......................................................................................

Process fitting / MaterialGN Thread ½NPT PN1000 / 316Ti ...................................................................................................GB Thread ½NPT inner thread (ASME B1.20.1) PN1000 / 316L .....................................................GD Thread ½NPT, inner ¼NPT (ASME B1.20.1) PN600 / 316Ti .....................................................CC Clamp 1½" PN16(ø50.5mm) DIN32676,ISO2852 /316L ............................................................CA Clamp 2" PN16(ø64mm) DIN32676,ISO2852 /316L ..................................................................F1 Flange 1" 150lb RF, ANSI B16.5 / 316L .....................................................................................FH Flange 2" 150lb RF, ANSI B16.5 / 316L .....................................................................................FI Flange 3" 150lb RF, ANSI B16.5 / 316L .....................................................................................

Seal measuring cell / Process temperatureX without / -30...105°C .............................................................................................................X without / -40...105°C .............................................................................................................

Pressure / Measuring rangeU rel. / 0...500 psi ..............................................................................................................W rel. / 0...1500 psi ............................................................................................................X rel. / 0...3000 psi ............................................................................................................S rel. / -14.5...9 psi ...........................................................................................................O rel. / -14.5...45 psi .........................................................................................................P rel. / -14.5...60 psi .........................................................................................................Q rel. / -14.5...200 psi .......................................................................................................Z rel. / 0...9000 psi ............................................................................................................

ElectronicsZ 4 ... 20 mA ...............................................................................................................H 4...20mA/HART® .....................................................................................................P Profibus PA ..............................................................................................................F Foundation Fieldbus ................................................................................................

Housing / ProtectionK Plastic / IP66/IP67 ............................................................................................A Aluminium / IP66/IP67 ......................................................................................D Aluminium double chamber / IP66/IP67 ...........................................................V StSt (precision casting) 316L / IP66/IP67 .........................................................8 StSt (electropolished) 316L / IP66/IP67 ...........................................................R Plastic double chamber / IP66/IP67 .................................................................

Cable entry / Cable gland / Plug connectionN ½NPT / without / without ............................................................................

Indicating/adjustment module (PLICSCOM)X without .................................................................................................A mounted ...............................................................................................

Accuracy classM 0.075 % .........................................................................................E 0.10% ............................................................................................S 0.20% ............................................................................................

BR53.

Pres

sure

Page 14: Process Pressure - AC Controls

154

SW 36 mm(1.42")

ø 29,3 mm (1.15")

30 m

m(1

18")

104,

8 m

m (

413

")

ø 24,7 mm (0.97")

1" NPT

1 2

3

SW 27 mm(1.06")

G ½

ø 27 mm (1.06")

ø 27 mm (1.06")

20,8

mm

(082

")

45 m

m(1

77")

ø 18,4 mm (0.72") ø 27,4 mm

(1.08")

29 m

m(1

14")

48 m

m(1

89")

ø 25 mm (0.98")

SW 32 mm(1.26")

M30 x 1,5

Process Pressure – VEGABAR 54

1 Threaded version G½

2 Threaded version M30 x 1,5, absolutely front-flush

3 Threaded version 1" suitable for PASVE ball valve fitting

VEGABAR 54 Pressure transmitter with MINI-CERTEC® measuring cell Application area The VEGABAR 54 pressure transmitter can be used universally for the measurement of gases, vapours and liquids with smallest, front-flush process fittings. Even substances such as sand are no problem for the abrasion-resistant ceramic measuring cell. The VEGABAR 54 offers maximum reliability and safety. Due to the operational flexibility, the sensor can be used in all industries. Advantages High plant availability through maximum overload and vacuum resistance of the

ceramic measuring cell Measurement down to the last drop through smallest measuring ranges with high

measuring accuracy Low maintenance costs due to wear-free ceramic measuring cell Technical data Measuring cell: MINI-CERTEC® Measuring range: -1 … +60 bar (-100 … +6000 kPa) Process fitting: thread from G½ flanges from DN 25, 1" hygienic fittings Process temperature: -40 … +120 °C Deviation in characteristics: 0.2 %; 0.1 % SIL qualification: up to SIL2

Page 15: Process Pressure - AC Controls

155Process Pressure – VEGABAR 54

ApprovalXX without ..................................................................................................................................................................KX CSA(NI)CL I,DIV 2,GP ABCD(DIP)CL II,III,DIV1,GP EFG ....................................................................................KF CSA(IS)CL I,II,III, DIV1, GP ABCDEFG ...............................................................................................................

Process fitting / MaterialGT Thread 1"NPT front-flush PN60/316L ...........................................................................................................CD Tri-Clamp ISO2852-1" PN16 / 316L .............................................................................................................RK KING ES2 according to MB3592 / 316L .......................................................................................................RE Bolting DN25PN40 DIN11851/316L ZB3981 ................................................................................................PC PMC 1" front-flush ........................................................................................................................................PD PMC 1¼" front-flush .....................................................................................................................................PE PMC 1½" front-flush .....................................................................................................................................F1 Flange 1" 150 b RF, ANSI B16.5 / 316L L ....................................................................................................

Seal measuring cell / Process temperature1 FKM (VP2/A) / -20...120°C .....................................................................................................................2 FFKM (Kalrez 6375) / -20...120°C ..........................................................................................................3 EPDM (A+P 75.5/KW75F) / -40...120°C ................................................................................................7 FKM - double / (VP2/A) / -20...120°C .....................................................................................................I EPDM - double (A+P 75.5/KW75F) / -40...120°C ...................................................................................

Pressure / Measuring rangeA rel. / 0...0.1bar (0...10kPa) ..............................................................................................................B rel. / 0...0.2bar (0...20kPa) ..............................................................................................................C rel. / 0...0.4bar (0...40kPa) ..............................................................................................................D rel. / 0...1.0bar (0...100kPa) ............................................................................................................E rel. / 0...2.5bar (0...250kPa) ............................................................................................................F rel. / 0...5.0bar (0...500kPa) ............................................................................................................G rel. / 0...10.0bar (0...1000kPa) ........................................................................................................T rel. / 0...25.0bar (0...2500kPa) ........................................................................................................

W rel. / 0...60.0bar (0...6000kPa) ........................................................................................................P rel. / -1...0.0bar (-100...0kPa) ..........................................................................................................Q rel. / -1...1.5bar (-100...150kPa) ......................................................................................................R rel. / -1...5.0bar (-100...500kPa) ......................................................................................................S rel. / -1...10.0bar (-100...1000kPa) ..................................................................................................H rel. / -1...25.0bar (-100...2500kPa) ..................................................................................................V rel. / -1...60.0bar (-100...6000kPa) ..................................................................................................L rel. / -0.1...0.1bar (-10...10kPa) .......................................................................................................M rel. / -0.2...0.2bar (-20...20kPa) .......................................................................................................1 abs. / 0...1.0bar (0...100kPa) ...........................................................................................................2 abs. / 0...2.5bar (0...250kPa) ...........................................................................................................3 abs. / 0...5.0bar (0...500kPa) ...........................................................................................................4 abs. / 0...10.0bar (0...1000kPa) .......................................................................................................5 abs. / 0...25.0bar (0...2500kPa) .......................................................................................................7 abs. / 0...60.0bar (0...6000kPa) .......................................................................................................

ElectronicsZ 4 ... 20 mA ................................................................................................................................H 4...20mA/HART® ......................................................................................................................P Profibus PA ..............................................................................................................................F Foundation Fieldbus .................................................................................................................

Housing / ProtectionK Plastic / IP66/IP67 .............................................................................................................A Aluminium / IP66/IP67 .......................................................................................................D Aluminium double chamber / IP66/IP67 .............................................................................8 StSt (electropolished) 316L / IP66/IP67 .............................................................................R Plastic double chamber / IP66/IP67 ...................................................................................

Cable entry / Cable gland / Plug connectionN ½NPT / without / without .............................................................................................

Indicating/adjustment module (PLICSCOM)X without ..................................................................................................................A mounted ................................................................................................................

Accuracy classE 0.10% ..............................................................................................................S 0.20% ..............................................................................................................

BR54.

Pres

sure

Page 16: Process Pressure - AC Controls

156

12

3

SW 46 mm(1.81")

G1 ½

78 m

m(3

07")

118

mm

(465

")46

mm

(181

")

22 m

m(0

87")

ø 55 mm(2.17")

78 m

m(3

07")

ø 64 mm(2.52")

ø 84 mm(3.31")

Process Pressure – VEGABAR 55

1 Threaded version G1½

2 Threaded version G1½, 200 °C

3 Clamp version 2"

VEGABAR 55 Pressure transmitter with METEC® measuring cell Application area The VEGABAR 55 is a pressure transmitter for pressure and level measurements in the chemical, food processing and pharmaceutical industry. The VEGABAR 55 offers the possibility to detect even smallest measuring ranges from 0.1 bar. Products are liquids and viscous products with higher temperatures. Advantages Excellent measuring accuracy even with strongly fluctuating process

temperatures High reliability through vacuum resistant version Very good cleanability and high chemical resistance through high resistance

diaphragm materials Technical data Measuring cell: METEC® Measuring range: -1 … +25 bar (-100 … +2500 kPa) Process fitting: thread from G½, ½ NPT flanges from DN 25 Process temperature: -12 … +200 °C Deviation in characteristics: 0.2 %; 0.1 %; 0.075 % SIL qualification: up to SIL2

Page 17: Process Pressure - AC Controls

157Process Pressure – VEGABAR 55

ApprovalUX FM(NI)CL I,DIV2,GP ABCD (DIP)CL II,III,DIV1,GP EFG ................................................................................UF FM(IS)CL I,II,III, DIV 1,GP ABCDEF ................................................................................................................UG FM(XP-IS) CLI,II,III, DIV 1, GP ABCDEFG ......................................................................................................KX CSA(NI)CL I,DIV 2,GP ABCD(DIP)CL II,III,DIV1,GP EFG ..............................................................................KF CSA(IS)CL I,II,III, DIV1, GP ABCDEFG ...........................................................................................................KG CSA(XP-IS) CLI,II,III, DIV 1, GP ABCDEFG ....................................................................................................

Process fitting / MaterialFQ Flange 1½"150lb RF,ANSI B16.5/316L ..................................................................................................ER Flange 1½"300lb lose/316L ZG3010 ......................................................................................................F5 Flange 2" 150lb RF, ANSI B16.5 / 316L .................................................................................................F2 Flange 2"300lb RF, ANSI B16.5/316L ....................................................................................................FO Flange 2"600lb RF,ANSI B16.5 / 316L ...................................................................................................FS Flange 3"150lb RF,ANSI B16.5/316L .....................................................................................................TU Flange 3"150lb RF,ANSI B16.5 with ext. ZG3177/316L ........................................................................FT Flange 3"300lb RF,ANSI B16.5/316L .....................................................................................................

GO Thread ½NPT, inner ¼NPT (ASME B1.20.1) PN25/316L .....................................................................GN Thread 1½NPT (ASME B1.20.1) PN60 / 316L .......................................................................................CA Clamp 2" PN16(ø64mm) DIN32676,ISO2852 /316L .............................................................................CB Clamp 3" PN10(ø91.0mm) DIN32676,ISO2852 /316L ..........................................................................LA Hyg. fitting w.compression nut F40PN40 / 316L ....................................................................................

Isolating liquid / TemperatureM Med.white oil / -12...140°C (Pabs<1bar-12..130°C) ........................................................................S Med.white oil,cool. / -12...180°C(Pabs<1bar-12...130°C) ................................................................R Med.white oil, cool./-12...200°C(Pabs<1bar-12...130°C) .................................................................

Pressure / Measuring rangeA rel. / 0...1.5 psi ............................................................................................................................B rel. / 0...3.0 psi ............................................................................................................................C rel. / 0...5.0 psi ............................................................................................................................P rel. / -14.5...0.0 psi ......................................................................................................................Q rel. / -14.5...20.0 psi ....................................................................................................................R rel. / -14.5...60.0 psi ....................................................................................................................S rel. / -14.5...150.0 psi ..................................................................................................................H rel. / -14.5...300.0 psi ..................................................................................................................L rel. / -1.5...1.5 psi ........................................................................................................................M rel. / -3.0...3.0 psi ........................................................................................................................

ElectronicsZ 4 ... 20 mA ............................................................................................................................H 4...20mA/HART® .................................................................................................................P Profibus PA ..........................................................................................................................F Foundation Fieldbus ............................................................................................................

Housing / ProtectionK Plastic / IP66/IP67 ........................................................................................................A Aluminium / IP66/IP67 ..................................................................................................D Aluminium double chamber / IP66/IP67 ......................................................................V StSt (precision casting) 316L / IP66/IP67 ....................................................................8 StSt (electropolished) 316L / IP66/IP67 .......................................................................R Plastic double chamber / IP66/IP67 .............................................................................

Cable entry / Cable gland / Plug connectionN ½NPT / without / without ........................................................................................

Indicating/adjustment module (PLICSCOM)X without ..............................................................................................................A mounted ...........................................................................................................

Accuracy classM 0.075 % .....................................................................................................E 0.10% .........................................................................................................S 0.20% .........................................................................................................

Additional equipmentX without ..................................................................................................

BR55.

Pres

sure

Page 18: Process Pressure - AC Controls

158

21

3

100 mm (3.94")

20 mm(0.79")

63 mm(2.48")

G ½

G ½79

mm

(311

")

75 m

m (2

95")

32

mm

(126

")

83 mm(3.27")

114 mm(4.49")

1/2

NP

T

150

mm

(591

")

1/2

NP

T

Process Pressure – Accessories

1 1-fold / G½ manometer / G½ socket

2 1-fold / ½ NPT adapter end / ½ NPT socket

3 2-fold / ½ NPT adapter end / ½ NPT socket

Version / Input / OutputG 1-fold / ½NPT adapter end / ½NPT socket ..................................................................................F 2-fold / ½NPT adapter end / ½NPT socket ..................................................................................

MaterialV Stainless steel ........................................................................................................................

Certificate / StandardX without ..............................................................................................................................

BARVALVE.

Valve Application area The use of a valve allows the simple installation and setup of the pressure transmitter. Advantages Simple mounting and dismounting of the pressure transmitter Ensures the simple sensor calibration without process interruption

Page 19: Process Pressure - AC Controls

159Process Pressure – Accessories

Electronics VEGABAR series 50

Instrument version50 Universal version ..................................................................................................................................

ElectronicsZ 4 ... 20 mA ......................................................................................................................................H 4...20mA/HART® ...........................................................................................................................P Profibus PA ....................................................................................................................................F Foundation Fieldbus .......................................................................................................................

for instrument approvalX XX ............................................................................................................................................

BR-E.

Pres

sure

Page 20: Process Pressure - AC Controls

160

G ½

180 mm (7.09")

56 mm(2.21")

200

mm

(787

")

155

mm

(610

") ø 6

mm

(024

")

145 mm (5.71")

G ½

G ½

G ½

ø 56 m

m

(2.21

")

110

mm

(433

")95

mm

(374

")

275

mm

(10

83")13

0 m

m (5

12")

Process Pressure – Accessories

Siphon in U-form Siphon in circular form

Version / Material19993 U-form, horizontal pressure extraction / 316Ti .....................................................................................40130 Circular form, vertical pressure tapping / 316Ti ....................................................................................

2

Siphon