EL-MF877-00 Page 1
Template Revision B
PSG instructions for this template are available at EL-MF877-01
Product End-of-Life Disassembly Instructions Product Category: Notebooks and Tablet PCs
Marketing Name / Model [List multiple models if applicable.]
HP ProBook 4535s Notebook PC
Purpose: The document is intended for use by end-of-life recyclers or treatment facilities. It provides the basic instructions for the disassembly of HP products to remove components and materials requiring selective treatment, as defined by EU directive 2002/96/EC, Waste Electrical and Electronic Equipment (WEEE).
1.0 Items Requiring Selective Treatment
1.1 Items listed below are classified as requiring selective treatment. 1.2 Enter the quantity of items contained within the product which require selective treatment in the right column, as applicable.
Item Description Notes
Quantity of items included in product
Printed Circuit Boards (PCB) or Printed Circuit Assemblies (PCA)
With a surface greater than 10 sq cm
3
Batteries All types including standard alkaline and lithium coin or button style batteries
2
Mercury-containing components For example, mercury in lamps, display backlights, scanner lamps, switches, batteries
Liquid Crystal Displays (LCD) with a surface greater than 100 sq cm
Includes background illuminated displays with gas discharge lamps
1
Cathode Ray Tubes (CRT)
Capacitors / condensers (Containing PCB/PCT)
Electrolytic Capacitors / Condensers measuring greater than 2.5 cm in diameter or height
External electrical cables and cords
Gas Discharge Lamps
Plastics containing Brominated Flame Retardants weighing > 25 grams (not including PCBs or PCAs already listed as a separate item above)
Components and parts containing toner and ink, including liquids, semi-liquids (gel/paste) and toner
Include the cartridges, print heads, tubes, vent chambers, and service stations.
Components and waste containing asbestos
EL-MF877-00 Page 2
Template Revision B
PSG instructions for this template are available at EL-MF877-01
Components, parts and materials containing refractory ceramic fibers
Components, parts and materials containing radioactive substances
2.0 Tools Required
List the type and size of the tools that would typically be used to disassemble the product to a point where components and materials requiring selective treatment can be removed.
Tool Description Tool Size (if applicable)
Description #1 Motor-screw-driver “+”
Description #2 Motor-screw-driver “*”
Description #3 Motor-screw-driver “-”
Description #4
Description #5
3.0 Product Disassembly Process
3.1 List the basic steps that should typically be followed to remove components and materials requiring selective treatment:
1. Follow steps described in Disassembly instruction (file attached). 2. If parts can be removed without using a tool, remove it first. 3. Use correct screwdriver and torque value before unlock the screw 4. 5. 6. 7. 8.
3.2 Optional Graphic. If the disassembly process is complex, insert a graphic illustration below to identify the items contained in the product that require selective treatment (with descriptions and arrows identifying locations).
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble Battery
1. Disassemble Battery (Fig.1)
1(1/1)
1.00 2011/02/11
电池Fig.1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
. Loosen Battery screws
2(1/1)
1.00 2011/02/11
1. Loosen SET screws (6052B0096601) *1
Disassembly bottom cover (Fig.2)
Torsion:1.5 ± 0.2 Kg/cm.
Screws can't be stripped.
Fig.2
SIM Card 1
导角在右前方插入
Fig.1
Electronic opener of the cross 1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassembly Bottom cover
3(1/1)
1.00 2011/02/11
Fig.1
1. Take out the Bottom cover
(6070B0492301)from
the complete machine down (Fig.1)
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
4(1/1)
Electronic opener of the cross 1
1.00 2011/02/11Disassemble ODD & loosen screw
1. Loosen screw of
ODD(6052A0010201) *1
(Fig.2)
Torsion:2.0 ± 0.2 Kgf.cm。
The screw can’t be stripped and
can’t be fall into the machine.
2. Take out the ODD from the left
BTCB (Fig.1)。
Fig.1
Fig.2
1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Tear master label
5(1/1)
1.00 2011/02/11
1. Tear the Master label (6060B1218301) from the
lower shell
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble DDR RAM
6(1/1)
1.00 2011/02/11
1. Disassemble DDR RAM from upper right corner
of M/B.
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Loosen HDD lower shell screws
1. Loosen HDD lower shell screws
(6052B0096601) *4(Fig.1)
Torsion:1.5 ± 0.2 Kgf.cm。
The screw can’t be stripped and
can’t be fall into the machine.
7(1/1)
1.00 2011/02/11
Electronic opener of the cross 1
Fig.1
4
3
2
1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble HDD
1.Draw HDD backward from M/B end
CNTR , take the HDD out from the
trough, (Fig.1)。
8(1/1)
1.00 2011/02/11
Electronic opener of the cross 1
Fig.1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
9(1/1)
Electronic opener of the cross
1
螺丝供应器 1
HDD supporting fixture 1
1.00 2011/02/11Disassemble HDD
1. Put HDD on supporting fixture.(Fig.1)
2. Loosen screws(6052B0131801)*4. (Fig.2)
Torsion:2.5 ± 0.2 Kgf.cm。
The screw can’t be stripped and can’t be
fall into the machine.
Fig.2
Fig.1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
10(1/1)
1.00 2011/02/11
assembling line bar 1
1. Disassemble WWAN aerial from the WWAN.
Fig.1
Disassemble WWAN line of 5/6
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble WWAN card & loosen screws
11(1/1)
1.00 2011/02/11
Electronic opener of the cross 1
Fig.1
【有WWAN时】
1.Lossen screws(6052B0096601 M2*3)*2 (Fig.1)
Torsion:1.5 ± 0.2 Kgf.cm。
The screw can’t be stripped and can’t be
fall into the machine.
2. Take out WWAN card from M/B end lower
CNTR and Tear WWAN module from
date label, (Fig.1)。
Take out in 30 degrees of M/B CNTR, no
have crookedly.
Press above CNTR with the finger .
1 2
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
12(1/1)
1.00 2011/02/11
assembling line bar 1
1. Take out WLAN Antenna cable (2号) from 1~4
trough.(Fig.1)
Fig.1
Disassemble WLAN line of 2
1
2
3
4
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble WLAN line of 1
13(1/1)
1.00 2011/02/11
assembling line bar 1
1. Take out WLAN Antenna cable (1号) from 1~4
trough.(Fig.1)
Fig.1
1
2
3
4
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble WLAN card & loosen screws
14(1/1)
1.00 2011/02/11
Electronic opener of the cross 1
1. Tear WLAN module with Date label from lower
CNTR of M/B end.
Take out in 30 degrees of M/B CNTR, no have
crookedly.
Press above CNTR with the finger .
2. Loosen screws(6052B0096601 M2*3) *2 (Fig.1)
Torsion:1.5 ± 0.2 Kgf.cm。
Screws can’t be stripped and can’t be fall into
machine.
Fig.1
1 2
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Loosen battery trough screws
1. Loosen battery trough screws(6052B0096201)
*3
Torsion:1.5 ± 0.2 Kgf.cm。
Screws can’t be stripped and can’t be fall into
machine.
15(1/1)
1.00 2011/02/11
Electronic opener of the cross 1
321
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
16(1/1)
1.00 2011/02/11
1. Loosen screws from left of ODD.
(6052B0096601) *3.
Torsion:1.5 ± 0.2 Kgf.cm。
Screws can’t be stripped and can’t be fall into
machine.
Loosen screw from head to foot
Electronic opener of the cross 1
3
2
1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Loosen screw from BTCB of four corners
1. Loosen screw ( 6052B0185501) *4 from
BTCB of four corners.
Torsion:2.5 ± 0.2 Kgf.cm。
Screws can’t be stripped and can’t be
fall into machine.
17(1/1)
1.00 2011/02/11
梅花电动起子 1
4
32
1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Loosen(in bottom cover )screw
1. Loosen screw(6052B0185501) *3 。
Torsion:2.5 ± 0.2 Kgf.cm。
Screws can’t be stripped and can’t be fall into
machine.
18(1/1)
1.00 2011/02/11
3
21
梅花电动起子 1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
1. Loosen screws of keyboard
6052B0185501*3
Torsion:2.5 ± 0.2Kgf.cm。
Screws can’t be stripped and can’t
be fall into machine.
19(1/1)
1.00 2011/02/11
1
2
3
Loosen(in bottom cover)screw
梅花电动起子 1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
1. Loosen screws (6052A0039501 *2 )of
Keyboard .
Torsion:2.5 ± 0.2Kgf.cm。
Screws can’t be stripped and can’t be fall
into machine.
Loosen screw of K/B
20(1/1)
1.00 2011/02/11
Electronic opener of the cross 1
1
2
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble K/B of TPCB
21(1/1)
1.00 2011/02/11
1. Disassemble Keyboard from upper shell,
Open the lower side , disassemble both
sides 4 cards and 6 cards above. (Fig.1)
Fig.1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble K/B from upper shell
22(1/1)
1.00 2011/02/11
1. Take out FFC from middle broken hole of
M/B (Fig.1)
Fig.1
K/B FFC
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Take down FFC from M/B
1. Take down Power/B FFC from
M/B .(Fig.1)
For F/P时
2. Take down Finger/B FFC from M/B
CNTR从 (Fig.2)
23(1/1)
1.00 2011/02/11
Fig.1
Fig.2
Power/B
FFC
Finger/B
FFC
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble FFC from M/B
1. Disassemble speaker cable and
Launch/B FFC
from M/B end CNTR(Fig.1)
24(1/1)
1.00 2011/02/11
Fig.2
Speaker
CNTRLaunch/B
FFC
Fig.1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
1. Loosen upper screws(6052B0185501) *3。
Torsion: 2.5 ± 0.2Kgf.cm
Screws can’t be stripped and can’t be fall into
machine.
Loosen screws of upper and lower shell
25(1/1)
1.00 2011/02/11
23
1
梅花电动起子 1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
1. Loosen screws(6052B0185501) *3。
Torsion: 2.5 ± 0.2Kgf.cm
Screws can’t be stripped and can’t be fall into
machine.
26(1/1)
1.00 2011/02/11
3
1
2
梅花电动起子 1
Loosen screws of upper and lower shell
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble upper shell
1. Fetch the card colludes of low upper
shell from lower shell , then
disassemble both side the card
colludes , at last disassemble up
card colludes. (Fig.1)
27(1/1)
1.00 2011/02/11
Fig.1
4
2
5
1
23
6
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble FFC
1. Disassemble Card reader/B FFC from MB
CNTR(Fig.1)
28(1/1)
1.00 2011/02/11
Fig.
1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble Lid switch/B . Tear Mylar
29(1/1)
1.00
1.Tear Mylar from fan (6054B0662001).(Fig.2)
2. Disassemble Lid switch/B FFC MB CNTR.
CNTR
position
2011/02/11
Fig.2
Fig.1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
1. The right aerial through the hole of
BTCB.(Fig.1)
2 . Disassemble aerial from the 1~4
trough of lower shell (Fig.2)
30(1/1)
1.00Disassemble Hinge right aerial
Fig.1
Through line
position
Fig.2
4
3 21
2011/01/21
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble left aerial of Hinge
1. Disassemble low aerial from 1~3
trough of lower shell. (Fig.2)
2 . The left aerial through the hole of
BTCB.(Fig.1)
31(1/1)
1.00
Fig.1
Through line
position
Fig.2
3
2 1
2011/01/21
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble LCM line
1. Disassemble LCM cable from the
CNTR of M/B end.
2. Disassemble cable from the trough of
lower shell.
32(1/1)
1.00 2011/02/11
Fig.1
Fig.2
assembling line bar 1
NG
CNTR position
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
1. Loosen screw of left LCM.
(6052B0185501) *1 .(Fig.1)
Torsion:3.5 ± 0.2 Kg/cm。
Screws can’t be stripped and
can’t be fall into machine.
2. Disassemble Camera cable from
CNTR of M/B end, and take out
cable from trough of lower shell.
(Fig.2)
Loosen LCM screw
33(1/1)
1.00 2011/02/11
Fig.1
Fig.2
梅花电动起子 1
1
CNTR position
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble LCM and loosen screw
34(1/1)
1.00 2011/02/11
Fig.2
1. Loosen left screw .(Fig.1/Fig.2)
(6052B0185501) * 3
Torsion:3.5 ± 0.2 Kg/cm。
Screws can’t be stripped and can’t
be fall into machine.
Fig.1
2
3
1
梅花电动起子 1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
1. Disassemble FFC from CNTR of M/B end and
tear FFC. (Fig.2/Fig.3)
2.Lossen screws *2 (6052A0010201)
(Fig.1)。
torsion:1.5 ± 0.2 Kg/cm
Screws can’t be stripped and can’t be fall into
machine.
3. Disassemble USB/B from lower shell
(1310A2411401) 。
Disassemble USB/B
35(1/1)
1.00 2011/02/11
Electronic opener of the cross 1
Fig.1
Fig.2 Fig.3
1
2
背胶1
背胶2
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
36(1/1)
1.00
【 When there is RJ11 Modem 】
1. Disassemble end son from trough and the line
block the wall. (Fig.3)
2. Disassemble cable from the trough of lower
shell and tear acetic sticky tape.(Fig.2)(Fig.1 )
【 When there isn’t RJ11 Modem 】
1. Take out Dummy RJ11 from the RJ11 trough of
lower shell. (6070B0493001)(Fig.4)
Disassemble RJ11 cable
3 12
Fig.1
Fig.2
Fig.3 Fig.4
2011/01/21
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
【有RJ11 Modem时】
1.Loosen Modem screw(6052B0010201) *2
Torsion:2.0 ± 0.2 Kg/cm
Screws can’t be stripped and can’t be fall
into machine.
2. Disassemble RJ11 cable (6017B0300301 )
from Modem CNTR .(Fig.1)
Disassemble Modem from M/B CNTR.(Fig.3)
3.Tear label from Modem module
Disassemble Modem module
37(1/1)
1.00 2011/02/11
Fig.1
Fig.2
Electronic opener of the cross 1
2
1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
38(1/1)
1.00
1. Tear Mylar from CNTR of battery.(Fig.3)
2.Disassemble acetic Sticky tape from M/B.
Take out ODD/B FFC from CNTR of
M/B end .(Fig.2)
3.Loosen screws of low left on M/B.
(6052A0005201) *1 .(Fig.1)
Torsion: 2.0 ± 0.2 Kg/cm。
Screws can’t be stripped and can’t be
fall into machine.
Disassemble ODD/B FFC
Fig.1
Fig.2
screw
Fig.3
梅花电动起子 1
2011/02/11
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
39(1/1)
1.00 2011/02/11
1.Take out cable line during trough and
fan.( Fig.3)
2. Disassemble end son from DC hole of
lower shell , then disassemble DC in
cable from lower shell. (Fig.2)
3. Loosen screw of CNTR battery
(6052A0010201) *2 (Fig.1)。
Torsion:1.5 ± 0.2 Kg/cm。
Screws can’t be stripped and can’t be
fall into machine.
Disassemble BATT CNTR
Electronic opener of the cross 1
Fig.1
1 2
Fig.2
Fig.3
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
40(1/1)
1.00 2011/02/11
1. Lift up DC cable and battery cable, then
disassemble M/B from lower shell. (Fig.1)
Disassemble M/B from BTCB
Fig.1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble ODD/B
1. Pull out ODD/B from trough ,then
disassemble ODD/B from middle
position of lower shell. (Fig.1/Fig.2)
41(1/1)
1.00 2011/02/11
Fig.2
Fig.1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble FAN & cable
1. Put M/B on supporting fixture witch B side
towards up. (Fig.1)
2.Loosen screw and disassemble fan from up
right of M/B. (Fig.2)
Torsion:2.0 ± 0.2 Kgf.cm。
Screws can’t be stripped and can’t be fall into
machine.
42(1/1)
1.00 2011/02/11
Fig.1
M/B B side supporting fixture 1
Electronic opener of the cross 1
Fig.2
screwCNTR
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble Battery cable
1. Put M/B on supporting fixture witch B side
towards up. (Fig.1)
2.Disassemble acetic Sticky tape from DC in
cable(Fig.3)。
3. Disassemble Battery cable from middle up
position CNTR of M/B.(Fig.2)
43(1/1)
1.00 2011/02/11
Fig.1
M/B B side supporting fixture 1
Fig.2Fig.3
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble DC cable
1. Put M/B on supporting fixture witch B side
towards up. (Fig.1)
2. Disassemble DC in cable from right up position
CNTR of M/B.(Fig.2)
44(1/1)
1.00 2011/02/11
Fig.1
M/B B side supporting fixture 1
Fig.2
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble Thermal
For Discrete:
1. Put M/B on supporting fixture witch B side
towards up. (Fig.1)
2. Loosen thermal SET screw.
Discrete : screw * 2 . (Fig.2)
Torsion: 2.5 ± 0.2Kgf.cm
Screws can’t be stripped and can’t be fall into
machine.
Fetch and put Thermal can’t hold the place
manage copper.
45(1/1)
1.00 2011/02/11
M/B B side supporting fixture 1
Electronic opener of the cross 1
Fig.2
Fig.1
Discrete
2
1
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
Disassemble Thermal
1 .Put M/B on supporting fixture witch B side
towards up. (Fig.1)
2. Disassemble Thermal from M/B.
3. Loosen thermal SET screw。Discrete : screw * 4 . (Fig.2)
UMA : screw * 4 (Fig.3)
Torsion: 2.5 ± 0.2Kgf.cm
Screws can’t be stripped and can’t be fall into
machine.
46(1/1)
1.00 2011/02/11
M/B B side supporting fixture 1
Electronic opener of the cross 1
Fig.2
Fig.1
UMAFig.3
Discrete
1
2 3
4 1
2
4
3
注意事项︰手套每天作业前须检查,务必保证手套洁净,如有不洁需及时更换。
作 业 指 导 书
Document No. : SS11 Ramones FA DISASS’Y SOP Station :
Name : Ver. : Date :
治具清单(治具规格) 数量 治具清单(治具规格) 数量
制表: 发行部门:
Step:
牟世芹 IE
47(1/1)
1.00 2011/02/11
M/B B side supporting fixture 1
一字起 1
吸笔 1
Fig.1
1. Put M/B on supporting fixture witch B side
towards up.(Fig.1).
2. For 45W(CPU),disassemble maylar
(6054B0944401).
3. Disassemble CPU from CPU SOCKET,
(Anticlockwise loosen). (Fig.2)
Fig.2
Fig.3
Disassemble CPU