products portfolio | 2010 - amarc-chauffage.com€¦ · 5 direct exchange single family house...
TRANSCRIPT
district heating substations
PRODUCTS PORTFOLIO | 2010
Ed. 06
3
DIRECT D.H.W.
SC
HEATING ONLY
LEGEND:
INDIRECT D.H.W. SUPERHEATED WATER
HOT WATERCOOLING
HOT WATERSUPERHEATED
WATERCOOLING DIRECT D.H.W.
INDIRECT
D.H.W
PRIMARY CIRCUIT THERMAL PROJECT
90/65°C194/149°F
115/65°C239/149°F
7/11°C44.6/51.8°F
85/55°C185/131°F
85/55°C185/131°F
SECONDARY CIRCUIT THERMAL PROJECT
60/75°C140/167°F
60/75°C140/167°F
14/8°C57.2/46.4°F
25/50°C77/122°F
30/55°C86/131°F
PRESSURE LOSS (Δp)NOMINAL CONDITIONS
1st/2nd CIRCUITS
< 10 w.c.m. (1°)< 3 w.c.m. (2°)
< 10 w.c.m. (1°)< 3 w.c.m. (2°)
< 15 w.c.m. (1°)< 6 w.c.m. (2°)
< 10 w.c.m. (1°)< 3 w.c.m. (2°)
< 10 w.c.m. (1°)< 3 w.c.m. (2°)
MECHANICAL PLAN 1st/2nd CIRCUITS
PN25PN16
PN16PN10
PN25PN10
THERMAL OVERSIZE 20%
CERTIFIED DESIGN CE/PED - ISPESL
Δp EMERGENCY PENSTOCK 25 barg
OPTIMIZATION FLOW RATE LIMITATION, TEMPERATURE AND POWER SIMULTANEOUSDYNAMIC REMOTE CONTROL
STANDARD SPECIFICATIONS DHS
4
PRODUCT RANGE
SATBASICSATPLUSSATDESIGNSATEMBED
MONOBASICMONOPLUSMONODESIGNMONOEMBED
base
wal
lfil
ter
SAT and SAT MIDI
WALL SST
BASE SST
DRAINAGE FILTER
AVD 500
LIBERO 500
BOLZANOBASICBOLZANOPLUSBOLZANOEMBED
FONDOACS (D.H.W.)FONDOHEATINGFONDOCOMBI
MILANOC-S-D
TORINOC-S-DVARESEC-S-D
BIELLABIELLAD
COLOGNOC-S
User satellites units arranged forremote setting, reading and controlling
Single living unit wall substationheating and D.H.W. max 40 kW
Wall substation for heating or domestic hot water, max 80 kW
Wall substation for heating and/or domestic hot water, max 180 kW
Base substation with brazed plate heat exchanger, max 5000 kW
Base substation with gasketed plateheat exchanger, max 6000 kW
Cooling base substation max1000 kW
Drainage filter for district heating substations and power plants
man
agem
ent
syst
emAVD500
LIBERO500
Management system for district heating sst and power plant
Management system arranged for setting, reading and controlling district heating sst and power plant
5
Direct exchange Single Family House Satellites downstream connected to the building or city zone substation.
SAT - SATMIDI
Pos. Model Heating(kW)
DHW(Lt./min)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
Weight (kg)
1 SAT 18 18 13 ¾” ¾” 10 6 100 95 500x600x150 25
2 SAT 28 28 18 ¾” ¾” 10 6 100 95 500x600x150 25
3 SAT 35 35 22 ¾” ¾” 10 6 100 95 500x600x150 25
4 SAT MIDI 18 18 13 ¾” ¾” 10 10 100 95 500x600x150 25
5 SAT MIDI 28 28 18 ¾” ¾” 10 10 100 95 500x600x150 25
6 SAT MIDI 35 35 22 ¾” ¾” 10 10 100 95 500x600x150 25
USER SATELLITES UNIT 18 ÷35 kW | 13 ÷ 22 Lt./min.
Pos. Model Dimensions (mm)
Weight (kg)
7 KIT SAT PLUS 500x782x153 25
8 KIT SAT DESIGN 500x854x153 25
9 KIT SAT EMBED 500x1040x153 25
C
6
Heating or Heating + instantaneous Domestic Hot Water supply Wall Substations.
MONO
Pos. Model Heating(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
T max 1°(°C)
T max 2°(°C)
Dimensions(mm)
W.(kg)
10 MONO 18 C 18 ¾” ¾” 16 10 100 95 500x800x150 30
11 MONO 25 C 25 ¾” ¾” 16 10 100 95 500x800x150 30
12 MONO 30 C 30 ¾” ¾” 16 10 100 95 500x800x150 30
C
Pos. Model Heating(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
16 MONO 18 S 18 ¾” ¾” 16 10 130 95 500x800x150 30
17 MONO 28 S 28 ¾” ¾” 16 10 130 95 500x800x150 30
18 MONO 40 S 40 ¾” ¾” 16 10 130 95 500x800x150 30
Pos. Model Heating(kW)
DHW(Lt./min)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
19 MONO COMBI 18 S 18 13 ¾” ¾” 16 10 130 95 500x800x150 40
20 MONO COMBI 28 S 28 18 ¾” ¾” 16 10 130 95 500x800x150 40
21 MONO COMBI 40 S 40 22 ¾” ¾” 16 10 130 95 500x800x150 40
Pos. Model Heating(kW)
DHW(Lt./min)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
T max 1°(°C)
T max 2°(°C)
Dimensions(mm)
W.(kg)
13 MONO COMBI 18 C 18 13 ¾” ¾” 16 10 100 95 500x800x150 40
14 MONO COMBI 25 C 25 18 ¾” ¾” 16 10 100 95 500x800x150 40
15 MONO COMBI 30 C 30 22 ¾” ¾” 16 10 100 95 500x800x150 40
SINGLE LIVING UNIT WALL SUBSTATION 18 ÷ 40 kW / 13 ÷ 22 lt./min.
S
Pos. Model Dimensions(mm)
W.(kg)
22 KIT MONO PLUS 500x982x150 31
23 KIT MONO DESIGN 550x1054x150 33
24 KIT MONO EMBED 570x1040x150 35
S
C
7
Pos. Model Heating(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
25 BOLZANO 10 C 10 ¾” 1” 25 10 100 95 500x600x150 30
26 BOLZANO 15 C 15 ¾” 1” 25 10 100 95 500x600x150 30
27 BOLZANO 20 C 20 ¾” 1” 25 10 100 95 500x600x150 30
28 BOLZANO 25 C 25 ¾” 1” 25 10 100 95 500x600x150 30
29 BOLZANO 35 C 35 ¾” 1” 25 10 100 95 500x600x150 30
30 BOLZANO 45 C 45 ¾” 1” 25 10 100 95 500x600x150 30
Hot/Superheated water wall mounted compact substations - Heating and Domestic Hot Water.
BOLZANO
COMPACT WALL SUBSTATION 10 ÷ 80 kW
C
Pos. Model DHW(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
31 BOLZANO 20 C ACS D 20 ¾” 1” 25 10 100 95 500x600x150 28
32 BOLZANO 30 C ACS D 30 ¾” 1” 25 10 100 95 500x600x150 28
33 BOLZANO 40 C ACS D 40 ¾” 1” 25 10 100 95 500x600x150 28
34 BOLZANO 50 C ACS D 50 ¾” 1” 25 10 100 95 500x600x150 28
35 BOLZANO 60 C ACS D 60 ¾” 1” 25 10 100 95 500x600x150 28
36 BOLZANO 70 C ACS D 70 ¾” 1” 25 10 100 95 500x600x150 28
37 BOLZANO 80 C ACS D 80 ¾” 1” 25 10 100 95 500x600x150 28
C
Pos. Model DHW(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
38 BOLZANO 20 C ACS I 20 ¾” 1” 25 10 100 95 500x600x150 28
39 BOLZANO 30 C ACS I 30 ¾” 1” 25 10 100 95 500x600x150 28
40 BOLZANO 40 C ACS I 40 ¾” 1” 25 10 100 95 500x600x150 28
41 BOLZANO 50 C ACS I 50 ¾” 1” 25 10 100 95 500x600x150 28
42 BOLZANO 60 C ACS I 60 ¾” 1” 25 10 100 95 500x600x150 28
43 BOLZANO 70 C ACS I 70 ¾” 1” 25 10 100 95 500x600x150 28
44 BOLZANO 80 C ACS I 80 ¾” 1” 25 10 100 95 500x600x150 28
C
Pos. Model Heating(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
45 BOLZANO 10 S 10 ¾” 1” 25 10 130 95 500x600x150 30
46 BOLZANO 15 S 15 ¾” 1” 25 10 130 95 500x600x150 30
47 BOLZANO 20 S 20 ¾” 1” 25 10 130 95 500x600x150 30
48 BOLZANO 25 S 25 ¾” 1” 25 10 130 95 500x600x150 30
49 BOLZANO 35 S 35 ¾” 1” 25 10 130 95 500x600x150 30
50 BOLZANO 45 S 45 ¾” 1” 25 10 130 95 500x600x150 30
51 BOLZANO 60 S 60 ¾” 1” 25 10 130 95 500x600x150 30
S
8
Pos. Model Dimensions(mm)
W. (kg)
66 KIT BOLZANO PLUS 500x782x150 31
67 KIT BOLZANO EMBED 570x840x150 35
Pos. Model DHW(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
52 BOLZANO 20 S ACS D 20 ¾” 1” 25 10 130 95 500x600x150 28
53 BOLZANO 30 S ACS D 30 ¾” 1” 25 10 130 95 500x600x150 28
54 BOLZANO 40 S ACS D 40 ¾” 1” 25 10 130 95 500x600x150 28
55 BOLZANO 50 S ACS D 50 ¾” 1” 25 10 130 95 500x600x150 28
56 BOLZANO 60 S ACS D 60 ¾” 1” 25 10 130 95 500x600x150 28
57 BOLZANO 70 S ACS D 70 ¾” 1” 25 10 130 95 500x600x150 28
58 BOLZANO 80 S ACS D 80 ¾” 1” 25 10 130 95 500x600x150 28
Pos. Model DHW(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
59 BOLZANO 20 S ACS I 20 ¾” 1” 25 10 130 95 500x600x150 28
60 BOLZANO 30 S ACS I 30 ¾” 1” 25 10 130 95 500x600x150 28
61 BOLZANO 40 S ACS I 40 ¾” 1” 25 10 130 95 500x600x150 28
62 BOLZANO 50 S ACS I 50 ¾” 1” 25 10 130 95 500x600x150 28
63 BOLZANO 60 S ACS I 60 ¾” 1” 25 10 130 95 500x600x150 28
64 BOLZANO 70 S ACS I 70 ¾” 1” 25 10 130 95 500x600x150 28
65 BOLZANO 80 S ACS I 80 ¾” 1” 25 10 130 95 500x600x150 28
BOLZANO
Hot/Superheated water wall mounted compact substations - Heating and Domestic Hot Water.
COMPACT WALL SUBSTATION 10 ÷ 80 kW
S
S
9
Hot/Superheated water wall mounted substations Heating and Domestic Hot Water.
FONDO
WALL SUBSTATION 30 ÷ 180 kW
Pos. Model Heating(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
68 FONDO 30 C 30 1” 1½” 25 10 100 95 750x930x260 50
69 FONDO 60 C 60 1” 1½” 25 10 100 95 750x930x260 55
70 FONDO 90 C 90 1” 1½” 25 10 100 95 750x930x260 60
71 FONDO 120 C 120 1” 1½” 25 10 100 95 750x930x260 65
Pos. Model DHW(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
76 FONDO 30 C ACS I 30 1” 1½” 25 10 100 95 750x930x260 50
77 FONDO 60 C ACS I 60 1” 1½” 25 10 100 95 750x930x260 55
78 FONDO 90 C ACS I 90 1” 1½” 25 10 100 95 750x930x260 60
79 FONDO 120 C ACS I 120 1” 1½” 25 10 100 95 750x930x260 65
Pos. Model DHW(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
72 FONDO 30 C ACS D 30 1” 1½” 25 10 100 95 750x930x260 45
73 FONDO 60 C ACS D 60 1” 1½” 25 10 100 95 750x930x260 50
74 FONDO 90 C ACS D 90 1” 1½” 25 10 100 95 750x930x260 55
75 FONDO 120 C ACS D 120 1” 1½” 25 10 100 95 750x930x260 60
Pos. Model Heating(kW)
DHW(Lt./min)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
80 FONDO COMBI 30 C 30 13 1” 1½” 25 10 100 95 750x930x260 65
81 FONDO COMBI 60 C 60 18 1” 1½” 25 10 100 95 750x930x260 70
82 FONDO COMBI 90 C 90 22 1” 1½” 25 10 100 95 750x930x260 75
83 FONDO COMBI 120 C 120 24 1” 1½” 25 10 100 95 750x930x260 80
C
C
C
C
10
Hot/Superheated water wall mounted substations Heating and Domestic Hot Water.
FONDO
WALL SUBSTATION30 ÷ 180 kW
Pos . Model Heating(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
84 FONDO 30 S 30 1” 1½” 25 10 130 95 750x930x260 50
85 FONDO 60 S 60 1” 1½” 25 10 130 95 750x930x260 55
86 FONDO 90 S 90 1” 1½” 25 10 130 95 750x930x260 60
87 FONDO 120 S 120 1” 1½” 25 10 130 95 750x930x260 65
88 FONDO 150 S 150 1” 1½” 25 10 130 95 750x930x260 70
Pos. Model DHW(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
95 FONDO 30 S ACS I 30 1” 1½” 25 10 130 95 750x930x260 50
96 FONDO 60 S ACS I 60 1” 1½” 25 10 130 95 750x930x260 55
97 FONDO 90 S ACS I 90 1” 1½” 25 10 130 95 750x930x260 60
98 FONDO 120 S ACS I 120 1” 1½” 25 10 130 95 750x930x260 65
99 FONDO 150 S ACS I 150 1” 1½” 25 10 130 95 750x930x260 70
Pos. Model DHW(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
89 FONDO 30 S ACS D 30 1” 1½” 25 10 130 95 750x930x260 45
90 FONDO 60 S ACS D 60 1” 1½” 25 10 130 95 750x930x260 50
91 FONDO 90 S ACS D 90 1” 1½” 25 10 130 95 750x930x260 55
92 FONDO 120 S ACS D 120 1” 1½” 25 10 130 95 750x930x260 60
93 FONDO 150 S ACS D 150 1” 1½” 25 10 130 95 750x930x260 65
94 FONDO 180 S ACS D 180 1” 1½” 25 10 130 95 750x930x260 70
Pos. Model Heating(kW)
DHW(Lt./min)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
100 FONDO COMBI 30 S 30 13 1” 1½” 25 10 130 95 750x930x260 65
101 FONDO COMBI 60 S 60 18 1” 1½” 25 10 130 95 750x930x260 70
102 FONDO COMBI 90 S 90 22 1” 1½” 25 10 130 95 750x930x260 75
103 FONDO COMBI 120 S 120 24 1” 1½” 25 10 130 95 750x930x260 80
104 FONDO COMBI 150 S 150 30 1” 1½” 25 10 130 95 750x930x260 85
S
S
S
S
11
Hot/Superheated water base substation with brazed plate heat exchanger - Heating and Domestic Hot Water.
MILANO
BASE SUBSTATION50 ÷5000 kW
Pos. Model Heating(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
105 MILANO 50 C 50 20/20 50/50 25 10 100 95 1500x500x1835 153
106 MILANO 75 C 75 20/20 50/50 25 10 100 95 1500x500x1835 153
107 MILANO 100 C 100 25/20 50/50 25 10 100 95 1500x500x1835 157
108 MILANO 125 C 125 25/20 25/20 25 10 100 95 1500x500x1835 170
109 MILANO 150 C 150 40/25 50/50 25 10 100 95 1500x500x1835 175
110 MILANO 175 C 175 40/25 50/50 25 10 100 95 1500x500x1835 179
111 MILANO 200 C 200 25/40 50/50 25 10 100 95 1500x500x1835 179
112 MILANO 250 C 250 40/40 50/50 25 10 100 95 1500x500x1835 195
113 MILANO 300 C 300 40/40 65/65 25 10 100 95 1500x500x1835 199
114 MILANO 350 C 350 40/40 65/65 25 10 100 95 1500x500x1835 236
C
Pos. Model DHW(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
115 MILANO 50 C ACS D 50 20/20 50/50 25 10 100 95 1500x500x1835 153
116 MILANO 75 C ACS D 75 20/20 50/50 25 10 100 95 1500x500x1835 153
117 MILANO 100 C ACS D 100 25/20 50/50 25 10 100 95 1500x500x1835 153
118 MILANO 150 C ACS D 150 40/25 50/50 25 10 100 95 1500x500x1835 170
119 MILANO 200 C ACS D 200 25/40 50/50 25 10 100 95 1500x500x1835 175
120 MILANO 300 C ACS D 300 40/40 50/50 25 10 100 95 1500x500x1835 191
Pos. Model DHW(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
121 MILANO 50 C ACS I 50 20/20 50/50 25 10 100 95 1500x500x1835 153
122 MILANO 75 C ACS I 75 20/20 50/50 25 10 100 95 1500x500x1835 157
123 MILANO 100 C ACS I 100 25/20 50/50 25 10 100 95 1500x500x1835 157
124 MILANO 150 C ACS I 150 40/25 50/50 25 10 100 95 1500x500x1835 175
125 MILANO 200 C ACS I 200 25/40 50/50 25 10 100 95 1500x500x1835 184
126 MILANO 300 C ACS I 300 40/40 65/65 25 10 100 95 1500x500x1835 204
Serie
s 76
C
C
Pos. Model Heating(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
127 MILANO 400 C 400 40/50 80/80 25 10 100 95 1800x870x1650 287
128 MILANO 500 C 500 50/50 80/80 25 10 100 95 1800x870x1650 321
129 MILANO 600 C 600 50/65 80/80 25 10 100 95 1800x870x1650 339
130 MILANO 700 C 700 50/65 80/80 25 10 100 95 1800x870x1650 373
131 MILANO 800 C 800 65/65 100/100 25 10 100 95 1800x870x1650 373
132 MILANO 900 C 900 65/65 100/100 25 10 100 95 1800x870x1650 419
133 MILANO 1000 C 1000 65/65 100/100 25 10 100 95 1800x870x1650 419
Serie
s 30
0
C
12
Hot/Superheated water base substation with brazed plate heat exchanger - Heating and Domestic Hot Water.
MILANO
BASE SUBSTATION50 ÷ 5000 kW
Pos. Model Heating (kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1° (bar)
PN 2° (bar)
Tmax 1° (°C)
Tmax 2° (°C)
Dimensions (mm)
W. (kg)
134 MILANO 1000 C D 1000 80/80 100/100 25 10 100 95 2300x1450x1750 700
135 MILANO 1250 C D 1250 80/80 125/125 25 10 100 95 2300x1450x1750 750
136 MILANO 1500 C D 1500 80/100 125/125 25 10 100 95 2300x1450x1750 850
137 MILANO 2000 C D 2000 100/100 150/150 25 10 100 95 2300x1450x1750 900
138 MILANO 2500 C D 2500 125/125 200/200 25 10 100 95 2300x1450x1750 950
139 MILANO 3000 C D 3000 125/150 200/200 25 10 100 95 2300x1450x1750 1150
140 MILANO 3500 C D 3500 150/150 200/200 25 10 100 95 2300x1450x1750 1350
Serie
s 30
0D
C
Pos. Model DHW(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
141 MILANO 50 S ACS D 50 20/20 50/50 25 10 130 95 1500x500x1835 141
142 MILANO 75 S ACS D 75 20/20 50/50 25 10 130 95 1500x500x1835 141
143 MILANO 100 S ACS D 100 20/20 50/50 25 10 130 95 1500x500x1835 141
144 MILANO 150 S ACS D 150 25/20 50/50 25 10 130 95 1500x500x1835 154
145 MILANO 200 S ACS D 200 25/25 50/50 25 10 130 95 1500x500x1835 171
146 MILANO 300 S ACS D 300 25/25 65/65 25 10 130 95 1500x500x1835 171
147 MILANO 400 S ACS D 400 25/40 65/65 25 10 130 95 1500x500x1835 183
148 MILANO 500 S ACS D 500 40/40 65/65 25 10 130 95 1500x500x1835 187
Serie
s 76
S
Pos. Model DHW(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
149 MILANO 50 S ACS I 50 20/20 50/50 25 10 130 95 1500x500x1835 141
150 MILANO 75 S ACS I 75 20/20 50/50 25 10 130 95 1500x500x1835 141
151 MILANO 100 S ACS I 100 20/20 50/50 25 10 130 95 1500x500x1835 141
152 MILANO 150 S ACS I 150 25/20 50/50 25 10 130 95 1500x500x1835 158
153 MILANO 200 S ACS I 200 25/25 50/50 25 10 130 95 1500x500x1835 176
154 MILANO 300 S ACS I 300 25/25 65/65 25 10 130 95 1500x500x1835 180
155 MILANO 400 S ACS I 400 25/40 65/65 25 10 130 95 1500x500x1835 196
156 MILANO 500 S ACS I 500 40/40 80/80 25 10 130 95 1500x500x1835 205
S
13
Hot/Superheated water base substation with brazed plate heat exchanger - Heating and Domestic Hot Water.
MILANO
BASE SUBSTATION50 ÷ 5000 kW
Pos. Model Heating(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
157 MILANO 50 S 50 20/20 50/50 25 10 130 95 1500x500x1835 141
158 MILANO 75 S 75 20/20 50/50 25 10 130 95 1500x500x1835 141
159 MILANO 100 S 100 20/20 50/50 25 10 130 95 1500x500x1835 141
160 MILANO 125 S 125 20/20 50/50 25 10 130 95 1500x500x1835 158
161 MILANO 150 S 150 25/20 50/50 25 10 130 95 1500x500x1835 158
162 MILANO 175 S 175 25/20 50/50 25 10 130 95 1500x500x1835 163
163 MILANO 200 S 200 40/20 50/50 25 10 130 95 1500x500x1835 176
164 MILANO 250 S 250 25/25 50/50 25 10 130 95 1500x500x1835 180
165 MILANO 300 S 300 25/25 65/65 25 10 130 95 1500x500x1835 185
166 MILANO 350 S 350 40/25 65/65 25 10 130 95 1500x500x1835 189
167 MILANO 400 S 400 25/40 65/65 25 10 130 95 1500x500x1835 196
168 MILANO 500 S 500 40/40 80/80 25 10 130 95 1500x500x1835 200
Pos. Model Heating(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
169 MILANO 600 S 600 40/40 80/80 25 10 130 95 1800x870x1650 287
170 MILANO 700 S 700 40/50 80/80 25 10 130 95 1800x870x1650 287
171 MILANO 800 S 800 40/50 100/100 25 10 130 95 1800x870x1650 321
172 MILANO 900 S 900 40/50 100/100 25 10 130 95 1800x870x1650 321
173 MILANO 1000 S 1000 40/50 100/100 25 10 130 95 1800x870x1650 353
174 MILANO 1150 S 1150 40/65 100/100 25 10 130 95 1800x870x1650 373
175 MILANO 1300 S 1300 50/65 100/100 25 10 130 95 1800x870x1650 419
176 MILANO 1500 S 1500 50/65 100/100 25 10 130 95 1800x870x1650 450
Serie
s 76
Serie
s 30
0
Pos. Model Heating (kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1° (bar)
PN 2° (bar)
Tmax 1° (°C)
Tmax 2° (°C)
Dimensions (mm)
W. (kg)
177 MILANO 1000 S D 1000 50/65 100/125 25 10 130 95 2300x1450x1750 650
178 MILANO 1250 S D 1250 65/65 125/125 25 10 130 95 2300x1450x1750 650
179 MILANO 1500 S D 1500 65/65 125/150 25 10 130 95 2300x1450x1750 700
180 MILANO 2000 S D 2000 80/80 150/150 25 10 130 95 2300x1450x1750 800
181 MILANO 2500 S D 2500 80/80 150/200 25 10 130 95 2300x1450x1750 850
182 MILANO 3000 S D 3000 80/100 200/200 25 10 130 95 2300x1450x1750 900
183 MILANO 3500 S D 3500 100/100 200/200 25 10 130 95 2300x1450x1750 900
184 MILANO 4000 S D 4000 100/125 250/250 25 10 130 95 2300x1450x1750 1000
185 MILANO 4500 S D 4500 100/125 250/250 25 10 130 95 2300x1450x1750 1200
186 MILANO 5000 S D 5000 125/125 250/250 25 10 130 95 2300x1450x1750 1350
Serie
s 30
0D
S
S
S
14
Hot/Superheated water base substation with plate heat exchanger - Heating and Domestic Hot Water.
TORINO
BASE SUBSTATION50 ÷ 6000 kW
Pos. Model Heating(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
187 TORINO 50 C 50 20/20 50/50 16 10 100 95 1800x600x1650 268
188 TORINO 75 C 75 20/20 50/50 16 10 100 95 1800x600x1650 269
189 TORINO 100 C 100 25/20 50/50 16 10 100 95 1800x600x1650 274
190 TORINO 125 C 125 25/25 50/50 16 10 100 95 1800x600x1650 287
191 TORINO 150 C 150 40/25 50/50 16 10 100 95 1800x600x1650 291
192 TORINO 175 C 175 40/25 50/50 16 10 100 95 1800x600x1650 296
193 TORINO 200 C 200 25/40 50/50 16 10 100 95 1800x600x1650 297
194 TORINO 250 C 250 40/40 50/50 16 10 100 95 1800x600x1650 313
195 TORINO 300 C 300 40/40 65/65 16 10 100 95 1800x600x1650 318
196 TORINO 350 C 350 40/40 65/65 16 10 100 95 1800x600x1650 357
Pos. Model DHW(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
197 TORINO 50 C ACS D 50 20/20 50/50 16 10 100 95 1800x600x1650 265
198 TORINO 75 C ACS D 75 20/20 50/50 16 10 100 95 1800x600x1650 265
199 TORINO 100 C ACS D 100 25/20 50/50 16 10 100 95 1800x600x1650 265
200 TORINO 150 C ACS D 150 40/25 50/50 16 10 100 95 1800x600x1650 281
201 TORINO 200 C ACS D 200 25/40 50/50 16 10 100 95 1800x600x1650 282
202 TORINO 300 C ACS D 300 40/40 50/50 16 10 100 95 1800x600x1650 296
Pos. Model DHW(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
203 TORINO 50 C ACS I 50 20/20 50/50 16 10 100 95 1800x600x1650 265
204 TORINO 75 C ACS I 75 20/20 50/50 16 10 100 95 1800x600x1650 266
205 TORINO 100 C ACS I 100 25/20 50/50 16 10 100 95 1800x600x1650 268
206 TORINO 150 C ACS I 150 40/25 50/50 16 10 100 95 1800x600x1650 284
207 TORINO 200 C ACS I 200 25/40 50/50 16 10 100 95 1800x600x1650 287
208 TORINO 300 C ACS I 300 40/40 65/65 16 10 100 95 1800x600x1650 303
Serie
s M
6
C
C
C
15
Hot/Superheated water base substation with plate heat exchanger - Heating and Domestic Hot Water.
TORINO
BASE SUBSTATION50 ÷ 6000 kW
Pos. Model Riscaldamento(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
209 TORINO 400 C 400 40/50 80/80 16 10 100 95 2500x600x1650 596
210 TORINO 500 C 500 50/50 80/80 16 10 100 95 2500x600x1650 633
211 TORINO 600 C 600 50/65 80/80 16 10 100 95 2500x600x1650 649
212 TORINO 700 C 700 50/65 80/80 16 10 100 95 2500x600x1650 685
213 TORINO 800 C 800 65/65 100/100 16 10 100 95 2500x600x1650 695
214 TORINO 900 C 900 65/65 100/100 16 10 100 95 2500x600x1650 737
215 TORINO 1000 C 1000 65/65 100/100 16 10 100 95 2500x600x1650 747
216 TORINO 1250 C 1250 80/80 125/125 16 10 100 95 2500x850x1800 864
217 TORINO 1500 C 1500 100/100 150/150 16 10 100 95 2500x850x1800 990
218 TORINO 2000 C 2000 100/100 150/150 16 10 100 95 2500x850x1800 1210
Pos. Model Heating (kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1° (bar)
PN 2° (bar)
Tmax 1° (°C)
Tmax 2° (°C)
Dimensions (mm)
W. (kg)
219 TORINO 1000 C D 1000 50/50 100/100 16 10 100 95 2980x1450x1750 1300
220 TORINO 1250 C D 1250 50/50 100/100 16 10 100 95 2980x1450x1750 1350
221 TORINO 1500 C D 1500 50/50 100/100 16 10 100 95 2980x1450x1750 1380
222 TORINO 2000 C D 2000 65/65 100/100 16 10 100 95 2980x1450x1750 1500
223 TORINO 2500 C D 2500 65/65 100/100 16 10 100 95 2980x1450x1750 1540
224 TORINO 3000 C D 3000 80/80 125/125 16 10 100 95 2980x1450x1750 1700
225 TORINO 3500 C D 3500 80/80 125/125 16 10 100 95 2980x1450x1750 1700
Serie
s M
10Se
ries
M10
D
Pos. Model Heating(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
226 TORINO 50 S 50 20/20 50/50 16 10 130 95 1800x600x1650 255
227 TORINO 75 S 75 20/20 50/50 16 10 130 95 1800x600x1650 255
228 TORINO 100 S 100 20/20 50/50 16 10 130 95 1800x600x1650 257
229 TORINO 125 S 125 20/20 50/50 16 10 130 95 1800x600x1650 274
230 TORINO 150 S 150 25/20 50/50 16 10 130 95 1800x600x1650 274
231 TORINO 175 S 175 25/20 50/50 16 10 130 95 1800x600x1650 279
232 TORINO 200 S 200 40/20 50/50 16 10 130 95 1800x600x1650 292
233 TORINO 250 S 250 25/25 50/50 16 10 130 95 1800x600x1650 297
234 TORINO 300 S 300 25/25 65/65 16 10 130 95 1800x600x1650 304
235 TORINO 350 S 350 40/25 65/65 16 10 130 95 1800x600x1650 308
236 TORINO 400 S 400 25/40 65/65 16 10 130 95 1800x600x1650 316
237 TORINO 500 S 500 40/40 80/80 16 10 130 95 1800x600x1650 325
Serie
s M
6Se
ries
M6
S
C
C
16
Hot/Superheated water base substation with plate heat exchanger - Heating and Domestic Hot Water.
TORINO
BASE SUBSTATION50 ÷ 6000 kW
Pos. Model DHW(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
238 TORINO 50 S ACS D 50 20/20 50/50 16 10 140 95 1800x600x1650 252
239 TORINO 75 S ACS D 75 20/20 50/50 16 10 140 95 1800x600x1650 252
240 TORINO 100 S ACS D 100 20/20 50/50 16 10 140 95 1800x600x1650 252
241 TORINO 150 S ACS D 150 25/20 50/50 16 10 140 95 1800x600x1650 265
242 TORINO 200 S ACS D 200 25/25 50/50 16 10 140 95 1800x600x1650 281
243 TORINO 300 S ACS D 300 25/25 65/65 16 10 140 95 1800x600x1650 282
244 TORINO 400 S ACS D 400 25/40 65/65 16 10 140 95 1800x600x1650 293
245 TORINO 500 S ACS D 500 40/40 65/65 16 10 140 95 1800x600x1650 298
Pos. Model DHW(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
246 TORINO 50 S ACS I 50 20/20 50/50 16 10 140 95 1800x600x1650 252
247 TORINO 75 S ACS I 75 20/20 50/50 16 10 140 95 1800x600x1650 254
248 TORINO 100 S ACS I 100 20/20 50/50 16 10 140 95 1800x600x1650 255
249 TORINO 150 S ACS I 150 25/20 50/50 16 10 140 95 1800x600x1650 272
250 TORINO 200 S ACS I 200 25/25 50/50 16 10 140 95 1800x600x1650 290
251 TORINO 300 S ACS I 300 25/25 65/65 16 10 140 95 1800x600x1650 295
252 TORINO 400 S ACS I 400 25/40 65/65 16 10 140 95 1800x600x1650 310
253 TORINO 500 S ACS I 500 40/40 80/80 16 10 140 95 1800x600x1650 320
Serie
s M
6
Pos. Model Heating(kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1°(bar)
PN 2°(bar)
Tmax 1°(°C)
Tmax 2°(°C)
Dimensions(mm)
W.(kg)
254 TORINO 600 S 600 40/40 80/80 16 10 130 95 2500x600x1650 627
255 TORINO 700 S 700 40/50 80/80 16 10 130 95 2500x600x1650 631
256 TORINO 800 S 800 40/50 100/100 16 10 130 95 2500x600x1650 678
257 TORINO 900 S 900 40/50 100/100 16 10 130 95 2500x600x1650 681
258 TORINO 1000 S 1000 40/50 100/100 16 10 130 95 2500x600x1650 724
259 TORINO 1150 S 1150 40/65 100/100 16 10 130 95 2500x600x1650 756
260 TORINO 1300 S 1300 50/65 100/100 16 10 130 95 2500x600x1650 804
261 TORINO 1500 S 1500 50/65 100/100 16 10 130 95 2500x600x1650 804
262 TORINO 2000 S 2000 80/80 150/150 16 10 130 95 2500x850x1800 980
263 TORINO 2500 S 2500 80/80 150/150 16 10 130 95 2500x850x1800 1120
Serie
s M
10
S
S
S
Si
M10
17
Pos. Model Heating (kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1° (bar)
PN 2° (bar)
Tmax 1° (°C)
Tmax 2° (°C)
Dimensions (mm)
W. (kg)
264 TORINO 1000 S D 1000 50/50 100/100 16 10 130 95 2980x1450x1750 1280
265 TORINO 1250 S D 1250 50/50 100/100 16 10 130 95 2980x1450x1750 1320
266 TORINO 1500 S D 1500 50/50 100/100 16 10 130 95 2980x1450x1750 1350
267 TORINO 2000 S D 2000 65/65 100/100 16 10 130 95 2980x1450x1750 1460
268 TORINO 2500 S D 2500 65/65 100/100 16 10 130 95 2980x1450x1750 1600
269 TORINO 3000 S D 3000 80/80 125/125 16 10 130 95 2980x1450x1750 1600
270 TORINO 3500 S D 3500 80/80 125/125 16 10 130 95 2980x1450x1750 1750
271 TORINO 4000 S D 4000 80/80 100/100 16 10 130 95 2980x1450x1750 1750
272 TORINO 4500 S D 4500 80/80 100/100 16 10 130 95 2980x1450x1750 1800
273 TORINO 5000 S D 5000 80/80 100/100 16 10 130 95 2980x1450x1750 1800
Serie
s M
10D
Hot/Superheated water base substation with plate heat exchanger - Heating and Domestic Hot Water.
TORINO - VARESE
BASE SUBSTATION50 ÷ 6000 kW
Pos. Model Heating (kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1° (bar)
PN 2° (bar)"
Tmax 1° (°C)
Tmax 2° (°C)
Dimensions (mm)
W. (kg)
282 VARESE 1000 S 1000 50/50 100/100 16 10 130 95 2800x950x2130 3050
283 VARESE 1250 S 1250 65/65 100/100 16 10 130 95 2800x950x2130 3050
284 VARESE 1500 S 1500 80/80 125/125 16 10 130 95 2800x950x2130 3150
285 VARESE 2000 S 2000 80/80 150/150 16 10 130 95 2800x950x2130 3200
286 VARESE 2500 S 2500 80/80 150/150 16 10 130 95 2800x950x2130 3200
287 VARESE 3000 S 3000 100/100 200/200 16 10 130 95 2800x950x2130 3250
288 VARESE 4000 S 4000 100/100 200/200 16 10 130 95 2800x950x2130 3250
289 VARESE 5000 S 5000 100/100 250/250 16 10 130 95 2800x950x2130 3250
290 VARESE 6000 S 6000 125/125 250/250 16 10 130 95 2800x950x2130 3350
Pos. Model Heating (kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1° (bar)
PN 2° (bar)
Tmax 1° (°C)
Tmax 2° (°C)
Dimensions (mm)
W. (kg)
274 VARESE 1000 C 1000 80/80 100/100 16 10 100 95 2800x950x2130 3080
275 VARESE 1250 C 1250 100/100 100/100 16 10 100 95 2800x950x2130 3080
276 VARESE 1500 C 1500 100/100 125/125 16 10 100 95 2800x950x2130 3180
277 VARESE 2000 C 2000 100/100 125/125 16 10 100 95 2800x950x2130 3230
278 VARESE 2500 C 2500 125/125 150/150 16 10 100 95 2800x950x2130 3230
279 VARESE 3000 C 3000 125/125 150/150 16 10 100 95 2800x950x2130 3280
280 VARESE 4000 C 4000 150/150 200/200 16 10 100 95 2800x950x2130 3290
281 VARESE 5000 C 5000 150/150 250/250 16 10 100 95 2800x950x2130 3300
Serie
s M
15
C
S
S
18
BIELLA
BASE SUBSTATION 50 ÷ 2500 kW Cooled water base substation with plate heat exchanger - Cooling only
Pos. Model Cooling (kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1° (bar)
PN 2° (bar)
Tmax 1° (°C)
Tmax 2° (°C)
Dimensions (mm)
W. (kg)
291 BIELLA 50 F 50 50/50 80/80 16 10 95 95 1800x870x1650 250
292 BIELLA 75 F 75 50/50 80/80 16 10 95 95 1800x870x1650 300
293 BIELLA 100 F 100 50/50 80/80 16 10 95 95 1800x870x1650 300
294 BIELLA 150 F 150 65/65 80/80 16 10 95 95 1800x870x1650 350
295 BIELLA 200 F 200 80/80 80/80 16 10 95 95 1800x870x1650 350
296 BIELLA 250 F 250 100/100 100/100 16 10 95 95 1800x870x1650 400
Serie
s 30
0
Pos. Model Cooling (kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1° (bar)
PN 2° (bar)
Tmax 1° (°C)
Tmax 2° (°C)
Dimensions (mm)
W. (kg)
297 BIELLA 300 F 300 100/100 100/100 16 10 95 95 3050x950x2100 850
298 BIELLA 350 F 350 100/100 100/100 16 10 95 95 3050x950x2100 950
299 BIELLA 400 F 400 125/125 125/125 16 10 95 95 3050x950x2100 950
300 BIELLA 500 F 500 125/125 125/125 16 10 95 95 3050x950x2100 1100
301 BIELLA 600 F 600 150/150 150/150 16 10 95 95 3050x950x2100 1150
302 BIELLA 700 F 700 150/150 150/150 16 10 95 95 3050x950x2100 1250
303 BIELLA 800 F 800 150/150 150/150 16 10 95 95 3050x950x2100 1250
304 BIELLA 900 F 900 200/200 200/200 16 10 95 95 3050x950x2100 1350
305 BIELLA 1000 F 1000 200/200 200/200 16 10 95 95 3050x950x2100 1350
Serie
s TL1
0
Pos. Model Heating (kW)
DN 1°(in/out)
DN 2°(in/out)
PN 1° (bar)
PN 2° (bar)
Tmax 1° (°C)
Tmax 2° (°C)
Dimensions (mm)
W. (kg)
306 BIELLA 1250 F 1250 200/200 200/200 16 10 95 95 3050x1900x2100 2300
307 BIELLA 1500 F 1500 250/250 250/250 16 10 95 95 3050x1900x2100 2550
308 BIELLA 2000 F 2000 250/250 250/250 16 10 95 95 3050x1900x2100 2700
309 BIELLA 2500 F 2500 300/300 300/300 16 10 95 95 3050x1900x2100 3200Serie
s TL1
0D
19
COLOGNO
Cleaning and drainage bag filter for 1st and 2nd district heating plant circuits.
DRAINAGE FILTER10 ÷ 40 m³/h
Pos. Model PN Tmax(°C)
Nominal Flow Rate (m³/h) DN in/out V
(litri)W.
(kg)
310 COLOGNO 15C 10 10 95°C 15 65-65 20 38
311 COLOGNO 15C 16 16 95°C 15 65-65 20 40
312 COLOGNO 15C 25 25 95°C 15 65-65 20 42
Pos. Model PN Tmax(°C)
Nominal Flow Rate (m³/h) DN in/out V
(litri)W.
(kg)
319 COLOGNO 15S 10 10 135°C 15 65-65 20 38
320 COLOGNO 15S 16 16 135°C 15 65-65 20 40
321 COLOGNO 15S 25 25 135°C 15 65-65 20 42
Pos. Model PN Tmax(°C)
Nominal Flow Rate (m³/h) DN in/out V
(litri)W.
(kg)
313 COLOGNO 25C 10 10 95°C 25 80-80 55 68
314 COLOGNO 25C 16 16 95°C 25 80-80 55 70
315 COLOGNO 25C 25 25 95°C 25 80-80 55 72
Pos. Model PN Tmax(°C)
Nominal Flow Rate (m³/h) DN in/out V
(litri)W.
(kg)
322 COLOGNO 25S 10 10 135°C 25 80-80 55 68
323 COLOGNO 25S 16 16 135°C 25 80-80 55 70
324 COLOGNO 25S 25 25 135°C 25 80-80 55 72
Pos. Model PN Tmax(°C)
Nominal Flow Rate (m³/h) DN in/out V
(litri)W.
(kg)
316 COLOGNO 40C 10 10 95°C 40 100-100 80 93
317 COLOGNO 40C 16 16 95°C 40 100-100 80 95
318 COLOGNO 40C 25 25 95°C 40 100-100 80 97
Pos. Model PN Tmax(°C)
Nominal Flow Rate (m³/h) DN in/out V
(litri)W.
(kg)
325 COLOGNO 40S 10 10 135°C 40 100-100 80 93
326 COLOGNO 40S 16 16 135°C 40 100-100 80 95
327 COLOGNO 40S 25 25 135°C 40 100-100 80 97
Serie
s 1
50Se
ries
250
Serie
s 3
50Se
ries
150
Serie
s 2
50Se
ries
350
C
S
C
C
S
S
20
00 : 00 01 : 00 02 : 00 03 : 00 04 : 00 05 : 00 06 : 00 07 : 00 08 : 00 09 : 00 10 : 00 11 : 00 12 : 00 13 : 00 14 : 00 15: 00 16 : 00 17 : 00 18 : 00 19 : 00 20 : 00 21 : 00 22 : 00 23 : 00 24 : 00
dP di rete
T6T4
T2
T1
E C
T5
FC
U7
U1
TR
TM
Q1
(U5/U6)
I1 TSH PSH
SICUREZZE
HC
Acquedotto
U8
USCITE / INGRESSI DIGITALI:
dPT
V1
U3 Segnalazione intervento sicurezze
I2 Consenso esterno al funzionamento
FC Ingresso imp. / Allarme Generico
Sanitario
(I6-I7 o I7)
I5Allarme pompa
U4 Segnalazione richiesta di priorità ACS
Allarme Perdite Rete
I3
Man. 1°
Rit. 1°
Regolatore
I4Allarme Filtro di
bonifica e pulizia
S 20
Pos. Modello Descrizione
328 AVD 500-R Meter-bus network configurable remote control for district heating substations
329 AVD 500-S Meter-bus network configurable remote control for district heating substations, domestic hot water management.
330 AVD 500-C Meter-bus network configurable remote control for domestic hot water boiler (1/2 stage or modulating)
331 AVD 500-P Meter-bus network configurable remote control for pumping system
332 AVD 500-CS Meter-bus network configurable remote control for substation’s secondary circuit and domestic hot water boiler
333 AVD 500-BY Meter-bus network configurable remote control for network control device
334 AVD 500-SQ Meter-bus network configurable remote control for substations and boiler start sequences management
335 AVD 500-F Meter-bus network configurable remote control for cooling substations
336 AVD 500-E Meter-bus network configurable remote control for water expansion system
Allarme Perdite Rete dP di rete dP impianto
E C
T5T6
U1
TR
TM
Q1
T2
I5(U5/U6)
RiscaldamentoI1
SICUREZZE
HC
(U7/U8)
T3
USCITE / INGRESSI DIGITALI:
I2 Consenso esterno al funzionamento
U3 Segnalazione intervento sicurezze
I3
I4
Allarme Filtro dibonifica e pulizia
Allarme termica pompa
Man. 1°
Rit. 1°
U4 Consenso esterno pompa
dPT (I6-I7 o I7)
V1
U2 *
FC Ingresso imp. / Allarme Generico* : Uscita 0-10V per controllo Inverter in dP (I6-I7 o solo I6) o dT (T1-T6 o T6-T4)
dPT (I6-I7 o I6)
Regolatore
TSH PSH T1
R 10
R10
heat
ing
subs
tatio
n
AVD 500
MANAGEMENT SYSTEM remote setting | reading | control
Specific programmable controller for district heating plants - AVD500.
S20
DH
W s
st w
ith s
tora
ge h
eate
r
21
S20
�� bar
RETE TLR
°C
T5°C
T1°C
T4
°C
T6
°C
T2
L
%V1
PERDITARETE
T
T
E C
kWh
m³/h
kW
TSH TSHH PSHH
S30
�� bar
RETE TLR
T5
T2
°C
°C
°CT1
L
%PERDITA
RETE
T
T
E C
kWh
m³/h
kW
TSH TSHH PSHHV1
LIBERO 500
Reading and management Software for District Heating plants optimization and management. Accessories and Hardware Components
MANAGEMENT SYSTEM remote setting | reading | control
Ethernet - IP
esempio tipico 3sistema wireless gsm - gprs
PC con softwarelibero 500
RVD230
AVD500
2WR6
Multical
2W
2
AVDVD5AVAVA
RRVRVD
2
lt
2WR5
MMMul
2
Actaris
Climax
Act
imCCCli
Hydrometer
satellite d’utenza
sst murale
sst basamento
ss
sasst st bt bbabaasstsss
HydromHydrHydHy
tete d’utesatesatelellillititsas
concentratore apparec-chiature METER-BUS
SERIALERS-232
modem GSM - GPRS
concentratore apparecchiatureMETER-BUS per singola sottostazione
modem GSM - GPRS
seria
le R
S-2
32
seria
le R
S-2
32
R10
�� bar �� bar
UTENZARETE TLR
T5
T2 T6
T1
°C
°C
°C
°C
%V1
PERDITARETE
T
T
E C
kWh
m³/h
kW
TSH TSHH PSHH
T3
°C
Pos. Model Description
337 SW 500 Libero 500: remote reading and control Software specific for District Heating networks and sst.
338 MLC 500 Heat Meters readings management module.
339 MF 500 Invoice generating module.
340 MA 500 Alarms management module.
341 MT 500 Network and substations operating parameters download and trend module.
Pos. Model Description
355 Kit ΔP02 Absolut and differential pressure measurement kit, including accessories and power pack, 0÷10V signal.
356 Kit BY-1/2/5/10/25/50 1/2/ 5/10/25/50 m³/h by-pass flow rate management NP25 valve, including 24V motor unit, 0÷10V command.
357 TE External temp measure sensor.
358 TF - 54/74/94 Fluids temp measure sensor (T max = 150°C) including AISI316 stainless steel shaft.
359 TFF - 250/350/500 Fumes temp measure sensor (T max = 400°C) including sliding fitting.
Pos. Modello Descrizione
342 CM - 1/2/3/6/10 1/2/3/6/10 conductors couples Meter-bus networks twisted cable, armoured, anti rodent sheath, external use.
343 P-Meter Meter-bus networks overloads protecting and shielding module.
344 BOX-L 2/5/10 Meter-bus data hub box for reading only. 2/5/10 devices.
345 BOX-LG 2/5/10 Meter-bus data hub box for reading and managing. 2/5/10 devices.
346QCM-L
20/60/120/240/360... Meter-bus data hub module for reading only. 20/60/120/240/360...devices.
347QCM-G
20/60/120/240/360... Meter-bus data hub module for control only. 20/60/120/240/360...devices.
348QCM-LG
20/60/120/240/360...Meter-bus data hub module for reading and managing. 20/60/120/240/360...
devices.
349(QCM/BOX) MOB (GSM) Meter-bus data switch mobile module: GSM.
350(QCM/BOX) MOB (GPRS) Meter-bus data switch mobile module: GPRS.
351(QCM/BOX)
MOB (UMTS) Meter-bus data switch mobile module: UMTS (HSDPA, HSVPA).
352 (QCM/BOX) 56k Meter-bus data receiver board sent via land line max 3/20/60/120/250... addresses.
353 (QCM/BOX) ETH Meter-bus data receiver board sent via Ethernet-IP max 3/20/60/120/250.../1000 addresses .
354QAM
120/240/360/480... Meter-bus power amp, for120/240/360/480..devices.