prolabs eon-omp-ocm datasheet€¦ · eon-omp-ocm mechanical size:l × w × h = 213mm ×...
TRANSCRIPT
EON-OMP-OCM
DATASHEET
INDEX
1 DESCRIPTION..............................................................................................................................................3
1.1 Product Function.................................................................................................................................3
1.2 Product Applications:........................................................................................................................3
2 OPTIC AND ELECTRIC SPECIFICATION..........................................................................................3
3 Operating / Storage Temperature and Humidity........................................................................3
4 EON-OMP-OCM Front Panel...............................................................................................................4
5 MECHANICAL DRAWINGS..................................................................................................................4
6 PRODUCT APPEARANCE AND MATERIAL...................................................................................4
7 Sample Wavelength Outputs...............................................................................................................5
1 DESCRIPTION
1.1 Product Function
The EON-OMP-OCM Interface card measures the optical spectrum, channel power, channel wavelength, channel OSNR, and total power on the monitored fibre. The module uses a tunable optical filter to de-multiplex and monitor 1529nm-1561nm, 100/50 GHz spaced optical channels.
1.2 Product Applications:
Compatible with Prolabs’ EON-OMP-2/EON-OMP-5 monitoring platforms
DWDM system error detection
DWDM system degraded aging test
NO. PARAMETER
2.1 Channel spacing
2.2
2.3
2.4
2.5
2.6
2.7
SPECIFICATION
2.8
2.9
2 OPTIC AND ELECTRIC SPECIFICATION
2.10
2.11
2.12
2.13
Wavelength range
Supported Signal Rate
Absolute wavelength accuracy
Channel power range
Absolute power accuracy
Relative power accuracy
Power resolution
Adjacent channel power divergence
Non-Adjacent channel power divergence
OSNR Range
OSNR accuracy
Scan time
Min Typical Max
50/100 -
1528 1568
10G
+/- 50
-40
+/-0.8
-10
1
0.1
6
10
25
+/-2
+/-1.5
1000
UNITS NOTE
GHz
nm
bits/s
pm
dBm
dB
ms
dB
dB
dB
dB
dB
dB
dB
Extended C-band
OSNR>20dB
OSNR<=20dB
NO. PARAMETER
3.1 Operating Temperature
3.2
3.3
3.4
SPECIFICATION
3 OPERATING/STORAGE TEMPERATURE AND HUMIDITY
Operating Humidity
Storage Temperature
Storage Humidity
UNITS
°C
%RH
°C
%RH
-10~65
5~95
-40~85
5~95
Page 3
4 EON-OMP-OCM FRONT PANEL
NO. PARAMETER
1 ALM
2
STATUS
ACK
DESCRIPTION
Indicate an Alarm ConditionRed
Flashing Green
The card is functioning normallyO�
O�
The card is functioning normally
The card is functioning normally
5 MECHANICAL DRAWINGS
EON-OMP-OCM Mechanical Size:L × W × H = 213mm × 154.5mm × 40.4mm
Figure 1 - EON-OMP-OCM - Mechanical structure diagram
6 PRODUCT APPEARANCE AND MATERIAL
Figure 2 – EON-OMP-OCM front panel schematic
1 MON LC/UPC MONITOR
There is an Optical interface on the panel of the OCM unit, and defined as below:
Page 4
There are 2 LED indicators on the EON-OMP-OCM front panel:
Visit www.prolabs.com for moreconnectivity solutions.
7 SAMPLE WAVELENGTH OUTPUTS
Monitoring results:
Central wavelength, Total power, Ch. Power, and OSNR
Users can config a Customer Tag for each wavelength
Independent alarm threshold/processing for each wavelength
Page 5