q1a=l fcas cbt=lcil~~jaf 3fft6 $tha pc:tljtag · film city, noida – 201301, uttar pradesh...
TRANSCRIPT
To,
q1a=l fcas Cbt=lcil~~Jaf 3fft6 $Tha 1 Pc:tlJtag ('lfml' ~ ~ ~)
POWER GRID CORPORATION OF INDIA LIMITED (A Government of India Enterprise) Qid"l~s
~ ~: ·~· ~ti. 2. ~-29, ~-122 001, ~) ~: 0124-2571700-719. $m : 0124-2571762, 'Saudaminl' Plot No. 2, Secior-29, Gurgaon-122 001, (Haryana} Tel.: 0124-2571700-719, Fax : 0124-2571762, Web.: www.powergridlndla.com
C/CTUNV/24 LTA CIN : L40101DL1989GOI038121 Date: 15-12-2016
As per Distribution List
Sub: 24th meeting of Western Region Constituents regarding Connectivity & Long term Access Applications of Western Region as per CERC Regulations, 2009.
Sir,
The 24th meeting of Western Region Constituents regarding Connectivity & Long term Access Applications of Western Region as per CERC Regulations, 2009 is proposed to be held on 21 .12.2016 (Wednesday). Agenda in this regard has already been circulated vide our letter dated 30.09.2016.
The agenda is also available at our website www.powergridindia.com>> CTU Open Access>>Meeting of Constituents & IPPs regarding Connectivity/MTOA/LTA Applications>>Western Region. Additional agenda for new connectivity and LTA applications is enclosed herewith. The date and venue for the meeting is as given below:
Date : Time : Venue:
21-12-2016 (Wednesday) 15.00 Hours. Northern Regional Power Committee 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi-110 016
It is requested to attend or depute your authorized representative for the meeting. The latest status of the generation project and the confirmation of participation along with no. of persons may be mailed to [email protected] and ramachand@powergrid india.com
Thanking You,
Encl. : As above
~ ~= <t"\ 9. ~ $til<; '{~l'l(it ~. 4icq1~<11 ~. ~ ~-110016 ~: 011-26560112, 26560121, 26564812, 26564892 .. ¢cm: 011-26601081 Regd. Office: B-9, Outab Institutional Area, Katwaria Sarai, New Delhi-110016 Tel.: 011-26560112, 26560121, 26564812, 26564892, Fax: 011-26601081 Web. wwwpowergridindia.com
~~i(l~@C"t q~~ Save Energy for Benefit of Self and Nation
1. Member (PS) Central Electricity Authority Sewa Bhawan, R.K.Puram New Delhi-110 066 :May kindly chair the meeting
2. The Member Secretary Western Regional Power Committee MIDC area, Marol, Andheri East, Mumbai 400 093
3. 3.
Chief Engineer (PSP&A - I) Central Electricity Authority Sewa Bhawan, R.K.Puram New Delhi-110 066
4. 4.
Director (Operation) Maharashtra State Electricity Transmission Co. Ltd., 4th Floor, “Prakashganga”, Plot No. C-19, E-Block, Bandra – Kurla Complex, Bandra(East), Mumbai- 400051
5. 5.
Managing Director Gujarat Energy Transmission Corp. Ltd, Sardar Patel Vidyut Bhawan, Race Course, Vadodara -390 007
6. 6.
Chairman & Managing Director Madhya Pradesh Power Transmission Co. Ltd., Block No. 3, Shakti Bhawan, Rampur, Jabalpur-482 008
7. 7.
Managing Director Chhattisgarh State Power Transmission Co. Ltd., Dangania, Raipur- 492 013
8. 8.
The Chief Engineer Electricity Department The Government of Goa, Panaji
9. 9.
Executive Engineer Administration of Daman & Diu (U.T.) Department of Electricity Moti Daman – 396220
10. 10.
Executive Engineer Electricity Department UT of Dadra & Nagar Havelli, Post Naroli-396 235, Silvassa
11. 11.
Chief Executive Officer POSOCO B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi-110 016
12. 12.
General Manager Western Regional Load Despatch Centre F-3, M.I.D.C. Area, Marol, Andheri East, Mumbai-400 093
13. Executive Director (Engg.) NTPC Ltd., Engg. Office Complex, Plot no. A-8A, Sector-24, Post Box. 13, Noida 201 301 (U.P)
14. 14.
Chief Engineer (Transmission) Nuclear Power Corporation of India Ltd., 12th Floor, North wing, Vikram Sarabhai Bhawan, Anushakti Nagar, Mumbai-400 094
15. Shri Ashish Shukla Senior Manager Gamesa Renewable Pvt. Ltd. (Mathak, Gagodar, Latur, Ghat Pimpri, Tuljapur/Deosingh & Kod Wind Power Projects) Future IT Prk, B-Block, 8th Flr, No. 334, Rajiv Gandhi Salai, Shollinganallur, Chennai-119, Tamil Nadu [email protected] Mob. 07869913518
16. Shri Lalit Birla AGM Orange Rajkot Wind Power Pvt. Ltd. & Orange Ashok North Wind Power Pvt. Ltd (Gagodar, Hajapar & Lohara Wind Projects) 301B, 3rd Floor, D21 Corporate Park, Sector-21 Dwarka, New Delhi – 110075 [email protected] Mob. 09650015982
17. Shri Alok Gupta General Manager-P.E. Inox Wind Infrastructure Services Ltd. (Bhachau, Dayapar & Bhuj Wind Farms) Inox Towers, Plot No. 17, Sector 16A, Film City, Noida – 201301, Uttar Pradesh [email protected] Mob. 09717364276
18. Shri M.R. Krishna Rao Vice President Adani Green Energy Ltd. (Khavda Wind Farm) Achalraj, Opposite Mayor Bungalow, Law Garden, Ahmedabad – 380006, Gujarat [email protected] Mob. 09099005556
19. Shri Naresh Panchal Senior GM & Head PE Suzlon Power Infrastructure Ltd. (Jevli, Baranda & Fulra Wind Farms) Level 1, Left Wing, Tree Suzlon, One Earth, Opposite Magarpatta, Pune-411028, Maharashtra [email protected] Mob. 09850829701
20. Shri Ujjwal Surana Sr. Manager, Srijan Energy System Pvt. Ltd. 102, EL TARA Building, Orchard Avenue, Hiranandani, Powai, Mumbai, 400076 [email protected] Mob. 9974552425
21. Shri Rakesh Garg AVP-Project Development Renew Power Ventures Pvt. Ltd. (Bhuvad & Osmanabad Wind Farm) 10th Floor, DLF Square, Jacranda Marg, DLF Phase-2, Sector 25, Gurgaon, Haryana [email protected] Mob. 09711486060
22. Shri Pratik Poddar Head, Project Development Ostro Kutch Wind Pvt. Ltd. Unit No. G-0, Ground Floor, Mira Corporate Suites, 1&2, Ishwar Industrial Estate, Mathura Road, New Delhi-110065 [email protected] Mob. 09810200736
23. Shri Dheeraj Jain AGM –Regulatory Affairs Regen Wind Farm (Vagarai) Pvt. Ltd. C/4, No. 22, Vaidya Rama Iyer Street, T Nagar, Chennai –600 017 [email protected] Mob. 09910778484
24. Shri Rakesh Garg AVP-Project Development Renew Power Ventures Pvt. Ltd. (Pugalur Wind Park) 10th Floor, DLF Square, Jacaranada Marg, Sector 25, DLF Phase-2, Gurgaon, Haryana [email protected] Mob. 09711486060
25. Shri V.K. Soni Head (Projects & New Initiatives) Gujarat Fluorochemicals Ltd. Inox Towers, Plot No. 17, Sector 16-A, Noida-201301, UP [email protected] Mob. 09891795111
26. Shri S R Singhal Sr. GM Wind World (India) Ltd., A-9, Veera Desai Road, Laxmi Industrial Estate, Wind World Tower, Andheri West, Mumbai – 53 [email protected]; [email protected] Mob. 7506342370 / 9820298218
27. Shri. K Kalaivendan Chief Development Officer Kshema Power and Infrastructure Company Pvt. Ltd., No. 34, 1st Floor, Defence Officer Colony, Ekkattuthangal, Chennai -32, Tamil Nadu. [email protected] Mob. 9444815386
28. Shri S Venkata Krishnan Sr. Manager BLP Vayu (Project 2) Pvt. Ltd., Avikiran Solar India Pvt. Ltd., 12th Floor, Crescent 1, Prestige Shantiniketan, ITPL Main Road, Hoodi, Whitefield, Bengaluru – 560048, Karnataka. [email protected] Mob. 9900085766
Addl. Agenda of 24th Meeting of WR constituents for Connectivity & LTA applications
1
Additional agenda for 24th meeting of WR Constituents regarding
Connectivity & Long-term Access applications in Western Region
----------------------------------------------------------------------------------------------------------------
1. Revision in the LTA quantum of Chhattisgarh State Power Trading Company
Ltd. (CSPTrCL)
a. M/s CSPTrCL through petition No. 84/MP/2016 to CERC, has prayed for
relinquishment of transmission capacity to the extent of 4699MW and 4985MW
in the ISTS under the BPTA dated 24.02.2010 and TSA dated 07.12.2010
respectively.
The details of LTA quantum requested to be surrendered by CSPTrCL from the
respective IPPs are mentioned at Annexure-I.
b. In this regard, the Hon’ble commission in terms of the ROP of this petition dated
28.06.2016, has directed CTU to utilize the relinquished capacity for grant of
LTA to the pending applications so that capacity does not remain unutilized. The
exercise for the utilisation of same has been carried out in the 23rd meeting of
WR constituents regarding connectivity / open access applications dated.
01.06.2016.
Commission in the refered ROP has further directed that the liability for
relinquishment charges of the petitioner will be decided in terms of the order in
the petition, and if the petitioner is held liable to pay the relinquishment charges,
the quantum of relinquishment charges will be decided in the light of the decision
taken on the basis of the recommendations of the Committee constituted in
Petition No. 92/MP/2015 for assessment / determination of stranded
transmission capacity with regard to relinquishment of LTA right by a long term
customer and relinquishment charges in terms of the provisions of the
Connectivity Regulations.
c. The revised allocation of LTA to CSPTrCL after considering the relinquishment
of LTA as per the refered petition from various IPPs in Chhattisgarh is as below:
Table: 1
Sl. No.
Generation Project Revised LTA requirement of CSPTrCL (Petition) with Target
beneficiary in WR
A. IPPs associated with HCTPC-V
1 RKM Powergen Ltd (4X360) 66
2 Athena Chhattisgarh Power Ltd. (2X600) 55
3 Jindal Power Ltd. (4X600) 110
4 SKS Power Gen. (Ch) Ltd. (4X300) 55
5 Korba West Power Co. Ltd. (1X600) 27
6 DB Power Ltd. (2X600) 55
7 KSK Mahanadi Power Co. Ltd. (6X600) 82
Addl. Agenda of 24th Meeting of WR constituents for Connectivity & LTA applications
2
8 Bharat Aluminium Co. Ltd. (4X300) 55
9 Vandana Vidyut Ltd. (2X135 + 1X270) 25
10 Lanco Amarkantak Power Pvt. Ltd. (2X660) 60
11 Visa Power Ltd. (1X600+1X660) 55
12 GMR Chhattisgarh Energy Pvt. Ltd. (2X685) 63
Total 708
B. IPPs associated with HCTPC-IV & Part System of HCTPC-I
1 Maruti Clean Coal & Power Ltd. (1x300 MW)
14
Total 14
Grand Total 722
Accordingly, it is proposed that the revised LTA intimation for the quantum as
mentioned above shall be issued to CSPTrCL and CSPTrCL would have to sign
revised LTA agreement / BPTA.
d. Here, it is to mention that while granting LTA to TRN Energy Pvt. Ltd.
(associated with HCPTC – V) and M/s Karnataka Power Corporation Ltd.,
(associated with Champa – Kurukshetra HVDC Bi-pole Phase 2 corridor) LTA
quantum of 210MW (WR: 126MW & NR:84MW) and 515MW (WR: 309MW &
NR: 206MW) respectively to CSPTrCL was mentioned in the intimation.
However, CSPTrCL has neither submitted separate application for this quantum
nor has signed BPTA for this quantum. Also CSPTrCL has not mentioned about
this quantum in the above mentioned Petition. In view of the above, 725MW
(210+515) shall not be considered against LTA to CSPTrCL.
2. LTA application for 450MW from Jaypee Nigrie Super Thermal Power Plant
(JNSTPP) of Jaiprakash Power Ventures Ltd. (JPVL)
a. M/s Jaiprakash Power Ventures Ltd. has applied for Long-term Access of
450MW from their 2x660MW Jaypee Nigrie Super Thermal Power Plant
(JNSTPP) located in dist. Nigrie, Madhya Pradesh.
Details of Application are as under-
Table 2
Sl. Particulars Application Details
1. Installed Capacity 2x660MW (1320MW)
2. Quantum for which LTA required 450MW
3. Date from which LTA required 30-10-2016
4. Date upto which LTA required 29-10-2031
5. Location of Generating Station Dist. Nigrie, Madhya Pradesh
6. Drawl of Power NR: 450MW (Target)
Addl. Agenda of 24th Meeting of WR constituents for Connectivity & LTA applications
3
b. Earlier, M/s JPVL was granted LTA for 1240.8MW [MPPMCL: 465.3MW (firm),
WR-388.2MW (target) & NR-387.3MW (target)] from their 2x660MW JNSTPP
with the commissioning of HCPTC IV and part system of HCPTC I. The
Transmission system for LTA of JPVL (i.e. HCPTC IV and part system of
HCPTC I) is commissioned. Presently, LTA of 465.3MW is operational for
MPPMCL.
c. However M/s JPVL has approached CERC vide petition no. 293/MP/2015 for
relinquishment of 775.5 MW leaving balance of 465.3MW LTA to MPPMCL. This
LTA of 465.3MW is already operational.
d. M/s JPVL has submitted the new LTA application for 450MW from its JNSTPP to
NR (target) from 30.10.2016. Studies have been carried out and following
transmission system is required for transfer of 450MW from the generation
project to NR, which is under implementation as part of different transmission
schemes (study results enclosed at Annexure – II):
Inter-Regional System Strengthening Scheme in WR and NR Part-B
i) Jabalpur PS - Orai 765kV D/C line
ii) Orai - Aligarh 765kV D/C line
iii) Orai - Orai 400kV D/C (Quad) line
iv) LILO of one ckt of Satna - Gwalior 765kV 2xS/C line at Orai
v) LILO of Agra - Meerut 765kV S/C at Aligarh
vi) LILO of Kanpur - Jhatikara 765kV S/C at Aligarh
Transmission System Strengthening in WR-NR Transmission Corridor For
IPPs in Chhattisgarh
i) Up-gradation of ± 800kV, 3000MW HVDC bipole between Champa PS –
Kurukshetra (NR) to 6000MW
ii) Kurukshetra (NR) – Jind 400kV D/c (Quad)
Members may discuss.
7. Connectivity with the Grid JNSTPP – Satna 400kV D/c (quad) line (commissioned)
8. Generation commissioning
schedule
U1: Commissioned in
Sep’14
U2: Commissioned in Feb’15
Addl. Agenda of 24th Meeting of WR constituents for Connectivity & LTA applications
4
3. Connectivity Applications from RE Generation Developers in Western Region
Details regarding new connectivity applications in WR are as tabulated below:
Table 3
Sl Name of Applicant (Organization)
Date of receipt of Application
Date from which connectivity required
Distance from Nearest PS (km)
Name of the Power Plant
S/s for which Connectivity Requested
Installed capacity of Plant (in MW)
Application No
Aplication Status
Generation Projects in vicinity of Bhuj PS, Gujarat
1 Ostro Kutch
Wind Pvt. Ltd. (OKWPL-Bhuj)
30-Sep-
2016 31-Mar-2019 40.00 Kutch 2 Bhuj PS 300 1200000493 Under
Process
2 Adani Green Energy Ltd.
(AGEL-Khavda)
27-Oct-
2016
31-Dec-2018 72.00 Khavda
Wind Farm Bhuj PS 1000 1200000514
Under Process
3 Adani Green Energy Ltd.
(AGEL-Khavda)
27-Oct-
2016
31-Dec-2018 72.00 Khavda
Solar Park Bhuj PS 750 1200000516
Under Process
4
Wind World (India) Ltd.
Mumbai (WWIL-Walka Mota)
28-Nov-
2016
31-Mar-2017 62.00 Wind World Bhuj PS 500 1200000553 Under
Process
Subtotal 2550
Generation Projects in vicinity of Osmanabad, Maharashtra
5
Renew Wind Energy (AP2)
Private Limited (RWEPL-
Osmanabad)
03-Oct-
2016
30-Jun-2019 40.00 Osmanabad Solapur (PG) 400 1200000496 Under
Process
6
Kshema Power & Infrastructure Company Pvt Ltd. (KPICPL-
Morda)
12-Nov-
2016
30-Mar-2018 40.00 Wind Power Solapur (PG) 250 1200000532 Under
Process
7
Suzlon Power Infrastructure Limited (SPIL-
Jevli)
23-Nov-
2016
31-Mar-2018 45.00 Jevli WGS Solapur (PG) 300 1200000550 Under
Process
8
Avikiran Solar India Private
Limited (ASIPL-Tuljapur)
6-Dec-
2016 31-Dec-2018 45 Avikiran
Solar India Pvt Ltd
Solapur (PG) 250 1200000555 Under
Process
Subtotal 1200
Generation Projects in vicinity of Kolhapur, Maharashtra
9
BLP Vayu (Project 2) Pvt. Ltd. (BLPVPL-
Bololi)
31-Oct-
2016
31-Jul-2018 17.00 BLP Vapu (Project 2) Pvt. Ltd.
Kolhapur 765/400kV
100 1200000509 Under
Process
Subtotal 100
Total 3850
Addl. Agenda of 24th Meeting of WR constituents for Connectivity & LTA applications
5
3.1 Connectivity Applications received in the vicinity of Bhuj :
Earlier, 7 nos. of connectivity applications were received at Bhuj P.S. for a quantum
of 2400MW [Connectivity Granted: 1 No. (for 300MW); connectivity Under Process
as per main agenda: 6 Nos. (for 2100MW)]. Now, 4 nos of new connectivity
applications (for 2550MW) have been received at Bhuj PS as given in table 3 above
(Sl. 1 to 4). Accordingly, total quantum of connectivity applications received till date
at Bhuj P.S. is 4950MW.
In the main agenda of the meeting circulated vide letter dated 30.09.2016, there was
only one applicant (connectivity quantum: 500MW) in Khavda, in the vicinity of Bhuj
PS. Accordingly, connectivity to the same was proposed at 220kV level at Bhuj PS.
However, now 2 more applications of quantum 1750MW in Khavda area have been
received. Therefore, it is prudent to optimise the connectivity system for all the three
applications together. Accordingly, the proposal at item 2.2 is partially amended for
M/s AGEL in Khavda area.
With 3 applications in Khavda area, the total power pooled shall be of the order of
2250MW. Therefore, it is now proposed to establish a common pooling station at
Khavda for providing connectivity to the applicants.
Considering the above as well as project capacity and proximity of the RE
generations to Bhuj PS, following transmission system is proposed for connectivity:
Table 4
Sl.
No.
Name of
Applicant
Connectivity
Quantum (MW)
Proposed Dedicated
Connectivity System
Implemeting
Agency
1 Ostro Kutch Wind Pvt. Ltd. (OKWPL-Bhuj)
300
OKWPL switchyard – Bhuj P.S.
220kV S/c (high capacity twin
zebra equivalent) line along with
associated line bays at both ends
OKWPL / TBCB as per deliberations in the meeting
2
Adani Green
Energy Ltd.
(AGEL-Khavda) 1000
Common Transmission System
for connectivity with ISTS Grid:
Establishment of 1x500MVA, 400kV P.S. at Khavda (Kutch)
Khavda P.S. – Bhuj Pooling Station 400kV D/c (quad) line along with associated line bays at both ends
Dedicated connectivity lines
under scope of generation
TBCB Generation developer (AGEL)
3.
Adani Green
Energy Ltd.
(AGEL-Khavda) 750
Addl. Agenda of 24th Meeting of WR constituents for Connectivity & LTA applications
6
Sl.
No.
Name of
Applicant
Connectivity
Quantum (MW)
Proposed Dedicated
Connectivity System
Implemeting
Agency
4 Adani Green Energy Ltd. (AGEL-Khavda)
500
developers
AGEL-Khavda (1000MW) Wind farm) – Khavda P.S. 400kV S/c (triple) line
AGEL-Khavda (750MW Solar Park) – Khavda P.S. 400kV S/c line
AGEL-Khavda (500MW Wind farm) – Khavda P.S. 220kV D/c line (high capacity twin zebra equivalent)
5 Wind World (India) Ltd. Mumbai (WWIL-Walka Mota)
500
WWIL – Bhuj P.S. 220kV D/c line
(high capacity twin zebra
equivalent) along with associated
line bays at both ends
WWIL / TBCB
as per
deliberations in
the meeting
Note:
1. As per the Manual on Transmission Planning Criteria, the ‘N-1’ criteria may not be applied to
the immediate connectivity of wind / solar farms with the ISTS / Intra-STS grid i.e. the line
connecting the farm to the grid and the step-up transformers at the grid station. In case, wind
farm developer envisages expansion in generation capacity, the same may be informed so
that connectivity system my be appropriately modified.
2. Connectivity of all six applicants with the grid shall be established with the commissioning of
above mentioned dedicated line and Bhuj PS (765/400/220kV) – Banaskantha PS (765kV) –
Sankhari (400kV) Corridor or Bhuj PS (765/400/220kV) – Banaskantha PS (765kV) –
Chittorgarh PS (765kV) – Chittorgarh (RVPN) (400kV) corridor.
Addl. Agenda of 24th Meeting of WR constituents for Connectivity & LTA applications
7
3.2 Connectivity Applications received in the vicinity of Solapur (Osmanabad) :
Earlier, 5 nos. of connectivity applications were received in the vicinity of Parli &
Solapur for a quantum of 1600MW which were proposed to be pooled at a new
pooling station near Latur area. Now, 4 nos of new connectivity applications (for
1200MW) have been received at Solapur (Osmanabad) as given in table 3 above
(Sl. 5 to 8). Accordingly, total 9 nos. connectivity applications for a total quantum of
2800MW in the Latur area has been received till date.
In the item 2.3 of the main agenda for 24th WR Connectivity/LTA meeting,
considering the large quantum of RE generation in the vicinity of Latur area, it has
been proposed to develop a new 400/220kV substation near Latur, which shall act
as a pooling station for RE generations in that area. Accordingly, following
transmission system is proposed for connectivity:
Common Transmission System for Connectivity of renewable generations
around Latur area (viz GRPL-Ghat Pimpri (100MW), GRPL-Ghat Pimpri
(500MW), GRPL-Latur, GRPL-Tuljapur-Deosingh, OANWPPL-Lohara, RWEPL-
Osmanabad, KPICPL-Morda, SPIL-Jevli and ASIPL-Tuljapur):
Establishment of 1x500MVA, 400/220kV Latur PS.
Latur PS – Solapur (PG) 400kV D/c (Quad) line
1x125MVAR, 420kV Bus Reactor at Latur PS.
Dedicated connectivity system for RE applicants proposed to be pooled at
Latur PS:
Table 5
Sr.
No.
Name of
Applicant
Connectivity
Quantum
(MW)
Proposed Dedicated
Connectivity System*
Implemeting
Agency
Connectivity Applications received in the vicinity of Solapur(Osmanabad):
1
Renew Wind Energy (AP2) Private Limited (RWEPL-Osmanabad)
400
RWEPL(Osmanabad) – Latur P.S. 220kV D/c line along with associated line bays at both ends
RWEPL / TBCB as per deliberations
in the meeting
2
Kshema Power & Infrastructure Company Pvt Ltd. (KPICPL-Morda)
250
KPICPL(Morda) – Latur P.S. 220kV
S/c line (high capacity twin zebra
equivalent) along with associated
line bays at both ends
KPICPL / TBCB as per deliberations
in the meeting
3
Suzlon Power Infrastructure Limited (SPIL-Jevli)
300
SPIL(Jevli) – Latur P.S. 220kV S/c line (high capacity twin zebra equivalent) along with associated line bays at both ends
SPIL / TBCB as per
deliberations in the meeting
4
Avikiran Solar India Private Limited (ASIPL-Tuljapur)
250
ASIPL(Tuljapur) – Latur P.S. 220kV S/c line (high capacity twin zebra equivalent) along with associated line bays at both ends
ASIPL/ TBCB as per
deliberations in the meeting
Addl. Agenda of 24th Meeting of WR constituents for Connectivity & LTA applications
8
*As per the Manual on Transmission Planning Criteria, the ‘N-1’ criteria may not be applied to the
immediate connectivity of wind / solar farms with the ISTS / Intra-STS grid i.e. the line connecting the
farm to the grid and the step-up transformers at the grid station. In case, wind farm developer
envisages expansion in generation capacity, the same may be informed so that connectivity system
my be appropriately modified.
Since connectivity required by the applicants mentioned above is from Mar’18 /
Jun’19, efforts may be made to implement Dedicated Connectivity System as well
as Common Transmission System for Connectivity of renewable generations
around Latur area at an early date.
3.3 Connectivity Applications received in the vicinity of Kolhapur :
The following new connectivity application has been received at Kolhapur (PG)
switching station as per details given in table 3 above (at Sl. No. 9). In view of project
capacity & proximity of generation, following transmission system is proposed for
connectivity:
Addl. Agenda of 24th Meeting of WR constituents for Connectivity & LTA applications
9
Table 6
Sl.
No
Name of Applicant Connectivity
Quantum (MW)
Proposed Dedicated
Connectivity System*
Implemeting
Agency
1 BLP Vayu (Project
2) Pvt. Ltd.
(BLPVPL-Bololi)
100
BLPVPL(Bololi) – Kolhapur GIS 220kV S/c line along with associated line bays at both ends
Installation of 1x500MVA, 400/220kV ICT at Kolhapur GIS*
*220kV cables shall be required for the interconnection of 400/220kV ICT to 220kV GIS module.
BLPVPL(Bololi)
*As per the Manual on Transmission Planning Criteria, the ‘N-1’ criteria may not be applied to the
immediate connectivity of wind / solar farms with the ISTS / Intra-STS grid i.e. the line connecting the
farm to the grid and the step-up transformers at the grid station. In case, wind farm developer
envisages expansion in generation capacity, the same may be informed so that connectivity system
my be appropriately modified.
The connectivity of BLVPL-Bololi with the grid shall be established after the
commissioning of above connectivity system or 31-07-2018 whichever is later.
4. LTA Applications from RE developers in Western Region
Earlier, 1 no of LTA application of M/s SESPL was received at Bhuj PS for a
quantum of 300MW {NR: 150MW (Target), WR: 90MW (Target), SR: 60MW
(Target)}. Now, four nos of new LTA applications have been received at Bhuj PS in
the month of Oct’16 to Dec’16 as tabulated below (which includes LTA application of
M/s AGEL which was discussed under item No. 4.1 of the main agenda for 24th WR
Connectivity/LTA meeting and whose system is to be reviewed considering collective
generation capacity from RE projects of M/s AGEL in Khavda area of Bhuj, Gujarat):
Table: 7
Sl
Name of the Applicant
Location of Generating
Station
Installed Capacity
(MW)
Connectivity
provided/proposed
at
Seeking LTA for (MW)
Type of
Fuel
Date of Receipt of App.
Date from which LTA required
Date upto which LTA required
Quantum allocated in the region
SR WR NR ER NER
LTA Applications in Western Region
1 Adani Green Energy Ltd (AGEL-Khavda)
WR (Khavda,
Kutch, Gujarat)
500 Bhuj PS 500 Wind 2-Jun-2016
31-Mar-2019
30-Mar-2044
- - 400 100 -
2 Adani Green Energy Ltd (AGEL-Khavda)
WR (Khavda,
Kutch, Gujarat)
1000 Bhuj PS 1000 Wind 31-Oct-
2016 31-Dec-
2018 30-Dec-
2043 - - 1000 - -
3 Adani Green Energy Ltd (AGEL-Khavda)
WR (Khavda,
Kutch, Gujarat)
750 Bhuj PS 750 Solar 31-Oct-
2016 31-Dec-
2018 30-Dec-
2043 - - 750 - -
Addl. Agenda of 24th Meeting of WR constituents for Connectivity & LTA applications
10
4
Inox Wind Infrastructure Services Ltd. (IWISL-Dayapar)
WR (Dayapar,
Kutch, Gujarat)
500 Bhuj PS 500 Wind 05-Dec-
2016 30-Jun-
2018 Jun-30-
2043 400 100
Grand Total 2750 - - 2550 200 -
As can be seen from Table 7 above, the total LTA quantum of 2750MW [2550MW
Target to NR and 200MW Target to ER] will be injected at Bhuj P.S. The high
capacity Green Energy Corridor starting from Bhuj PS (WR) to Moga (NR) is already
under implementation by POWERGRID for evacuation and dispersal of power from
renewable generations coming up in Gujarat (especially Kutch complex) and
Rajasthan.
System studies considering the above transfer of power to NR & ER have been
carried out. Study results are attached at Annexure – III. From the studies, following
is observed:
Bhachau – Versana 400kV D/c line grossly violates N-1 criteria (about
1475MW under N-1 outage)
Mundra UMPP – Bhachau 2xD/c (triple) line gets critically loaded and loading
reaches upto about 1200MW under N-1 outage
In order to relieve loading on the above lines, following is proposed:
LILO of EPGL – Bhachau 400kV D/c (triple) line at Halvad S/s (or Shapar S/s)
as proposed in the item no. 11 (Alternative utilization of Essar Power Gujarat
Ltd (EPGL) - Bhachau 400kV D/c (Triple) line of POWERGRID) of the 41st
WR SCM agenda.
Establishment of 2x500MVA, 400/220kV S/s at Bhachunda and Bhuj P.S. –
Bhachunda – Varsana 400kV D/c line under implementation by GETCO may
be expedited
Study results indicate that with the above measures, loading on Bhachau –
Varsana 400kV D/c line gets relieved significantly. Further, loading of Mundra
UMPP – Bhachau 2xD/c (triple) line also gets relieved to some extent and loading
reaches upto about 1000MW under N-1 outage.
Accordingly, transmission system for LTA of each of the above applicants is as
mentioned below:
Common Transmission System for LTA to ER & NR for IWISL-Dayapar
(500MW) wind farm
Installation of 2x500MVA, 400/220kV ICT at Bhuj P.S.*
Transmission System mentioned below. *The ICTs are also required under Common Transmission System for LTA of M/s SESPL to
WR, NR & SR
Addl. Agenda of 24th Meeting of WR constituents for Connectivity & LTA applications
11
Transmission System for LTA of:
500MW & 1000MW wind farms and 750MW solar park of M/s AGEL-
Khavda
500MW wind farm of M/s IWISL-Dayapar
i) Bhuj PS- Banaskantha PS 765kV D/c line#
ii) Banaskantha PS- Chittorgarh PS 765kV D/c line#
iii) Chittorgarh PS- Chittorgarh (RVPN) 400kV D/c (quad) line#
iv) LILO of EPGL – Bhachau 400kV D/c (triple) line at Halvad (or Shapar
Substation of GETCO as per discussions in the 41st WR SCM))
v) Establishment of 2x500MVA, 400/220kV S/s at Bhachunda and Bhuj P.S.
– Bhachunda – Varsana 400kV D/c line (under implementation by
GETCO)
#under implementation as part of Green Energy Corridors and expected to get
commissioned by July’18
The above LTA applications seeking power transfer to NR shall also be
discussed in the meeting of NR constituents for Connecticity/LTA applications so
that additional system strengthening requirement in NR (if any) may be identified.
5. Termination of Dedicated connectivity lines at ISTS substation using Multi-
circuit towers
a. RE generations proposed to be pooled at Bhuj P.S.
In view of large RE potential in the vicinity of Bhuj P.S. and in anticipation of more
connectivity applications to be received at Bhuj P.S., it is necessary to consider space
optimisation towards entry into Bhuj P.S. Accordingly, it is proposed that transmission
towers, upto 2km. periphery from Bhuj P.S., used for termination of dedicated
connectivity lines of RE generations may be of multi-circuit type and the generation
developers who would share the M/C towers (as per GPS coordinates of RE
generations) are as tabulated below:
Sl.
No.
Name of
Applicant
Connectivity
Quantum
(MW)
Proposed Dedicated
Connectivity Line
Sharing of M/C tower towards entry into Bhuj P.S.
Implemeting
Agency
1 Srijan Energy System Pvt Ltd. (SESPL)
300 SESPL switchyard – Bhuj PS 220kV D/c line along with line bays at both ends
M/C tower upto 2km. periphery from Bhuj
P.S.
SESPL
2.
Suzlon Power
Infrastructure Ltd
(SPIL-Fulra) 250
SPIL (Fulra) – Bhuj PS 220kV S/c
line (high capacity) along with
associated line bays at both ends
SPIL/ TBCB as per deliberations in the meeting
3
Suzlon Power
Infrastructure Ltd
(SPIL-Baranda) 250
SPIL (Baranda) – Bhuj PS 220kV
S/c line (high capacity) along with
associated line bays at both ends
SPIL/ TBCB as per deliberations in the meeting
4 Ostro Kutch Wind Pvt. Ltd.
300 OKWPL switchyard – Bhuj P.S. 220kV S/c (twin conductor) line
M/C tower upto 2km.
OKWPL / TBCB as per
Addl. Agenda of 24th Meeting of WR constituents for Connectivity & LTA applications
12
Sl.
No.
Name of
Applicant
Connectivity
Quantum
(MW)
Proposed Dedicated
Connectivity Line
Sharing of M/C tower towards entry into Bhuj P.S.
Implemeting
Agency
(OKWPL-Bhuj) along with associated line bays at both ends
periphery from Bhuj
P.S.
deliberations in the meeting
5
Inox Wind
Infrastructure
Services Ltd.
(IWISL-Kotda)
500
IWISL(Kotda) – Bhuj PS 220kV
D/c line (high capacity) along with
associated line bays at both ends
IWISL/ TBCB as per deliberations in the meeting
6
Orange Rajkot Wind Power Pvt. Ltd. (ORWPL-Hajapar)
100 ORWPL(Hajapar) – Bhuj PS
220kV S/c line along with associated line bays at both ends
ORWPL
7
Inox Wind Infrastructure Services Ltd. (IWISL-Dayapar)
500
IWISL(Dayapar) – Bhuj P.S. 220kV D/c line (high capacity twin
zebra equivalent) along with associated line bays at both ends
M/C tower upto 2km. periphery from Bhuj
P.S. or entire
common portion of
transmission line upto
Bhuj P.S.*
IWISL/ TBCB as per
deliberations in the
meeting
8
Wind World (India) Ltd. Mumbai (WWIL-Walka Mota)
500
WWIL (Walka Mota) – Bhuj P.S. 220kV D/c line (high capacity twin
zebra equivalent) along with associated line bays at both ends
WWIL/ TBCB as per
deliberations in the
meeting
*Based on GPS coordinates of the two RE projects, it is observed that most of the ROW upto
Bhuj P.S of M/s IWISL-Dayapar (500MW) and M/s WWIL-Walka Mota (500MW) is common for
dedicated connectivity lines of wind farms. Accordingly, the common portion of transmission line
(starting from wind farm of M/s WWIL) may be built using Multi-circuit tower (such that it can
accommodate 220kV D/c line of M/s IWISL-Dayapar as well as 220kV D/c line of M/s WWIL-
Walka Mota). Alternatively, the dedicated connectivity lines of both the RE projects may be built
individually and Multi-circuit towers shall then be used for termination into Bhuj P.S. (upto 2km
periphery from Bhuj P.S).
b. RE generations proposed to be pooled at Lakadia P.S.
In view of large RE potential in the vicinity of Lakadia P.S. and in anticipation of more
connectivity applications to be received at Lakadia P.S., it is necessary to consider
space optimisation towards entry into Lakadia P.S. Accordingly, it is proposed that
transmission towers, upto 2km. periphery from Bhuj P.S., used for termination of
dedicated connectivity lines of RE generations may be of double-circuit type and the
generation developers who would share the D/C towers (as per GPS coordinates of RE
generations) are as tabulated below:
Addl. Agenda of 24th Meeting of WR constituents for Connectivity & LTA applications
13
Sl.
No.
Name of
Applicant
Connectivity
Quantum
(MW)
Proposed Connectivity
Line
Sharing of D/C tower towards entry into Lakadia P.S.
Implemeting
Agency
1. Gamesha
Renewables Pvt
Ltd. (Gagodhar)
(GRPL-
Gagodhar)
300
GRPL (Gagodhar) – Lakadia PS 220kV S/c line (High Capacity) alongwith associated line bays at both ends
D/C tower upto 2km. periphery from Lakadia
P.S.
GRPL / TBCB as per deliberations in the meeting
2. Gamesha
Renewable Pvt.
Ltd. (Mathak)
(GRPL-Mathak) 100
GRPL (Mathak) – Lakadia PS 220kV S/c line alongwith associated line bays at both ends
GRPL
3. Orange Rajkot
Wind Power Pvt.
Ltd. (ORWPL-
Gagodhar)
100
ORWPL(Gagodhar) –
Lakadia PS 220kV S/c
line alongwith
associated line bays at
both ends
D/C tower upto 2km. periphery from Lakadia
P.S.
ORWPL
4. Gujarat Floro Ltd
(GFL-Maliya) 300
GFL(Maliya) – Lakadia PS 220kV S/c line (High Capacity) alongwith associatged line bays at both ends.
GFL / TBCB as per
deliberations in the
meeting
Relative positioning of various RE projects getting pooled at Bhuj P.S. and Lakadia P.S. in
Gujarat can be seen from the diagram below:
Addl. Agenda of 24th Meeting of WR constituents for Connectivity & LTA applications
14
c. RE generations proposed to be pooled at Latur P.S.
In view of large RE potential in the vicinity of Latur P.S. and in anticipation of more
connectivity applications to be received at Latur P.S., it is necessary to consider space
optimisation towards entry into Latur P.S. Accordingly, it is proposed that transmission
towers, upto 2km. periphery from Latur P.S., used for termination of dedicated
connectivity lines of RE generations may be of multi-circuit type and the generation
developers who would share the M/C towers (as per GPS coordinates of RE
generations) are as tabulated below:
Sr.
No.
Name of
Applicant
Connectivity
Quantum
(MW)
Proposed Connectivity Line Sharing of M/C tower towards entry into Latur P.S.
Implemeting
Agency
1
Gamesha
Renewables
Pvt. Ltd.
(GRPL-Ghat
Pimpri)
100
GRPL(Ghat Pimpri) – Latur
PS 220kV S/c line along with
associated line bays at both
ends M/C tower upto 2km. periphery from Latur
P.S.
GRPL
2
Gamesha
Renewables
Pvt. Ltd.
(GRPL-Ghat
Pimpri)
500
GRPL(Ghat Pimpri) – Latur
PS 220kV D/c line (high
capacity) along with
associated line bays at both
ends
GRPL / TBCB as per deliberations
in the meeting
3
Kshema Power & Infrastructure Company Pvt Ltd. (KPICPL-Osmanabad)
250
KPICPL(Osmanabad) – Latur
P.S. 220kV S/c line (high
capacity twin zebra
equivalent) alongwith
associated line bays at both
D/C tower upto 2km. periphery from Latur
P.S.
KPICPL / TBCB as per deliberations
in the meeting
Addl. Agenda of 24th Meeting of WR constituents for Connectivity & LTA applications
15
ends
4
Avikiran Solar India Private Limited (ASIPL-Tuljapur)
250
ASIPL(Tuljapur) – Latur P.S. 220kV S/c line (high capacity twin zebra equivalent) along with associated line bays at both ends
ASIPL/ TBCB as per deliberations
in the meeting
5
Gamesha
Renewables
Pvt. Ltd.
(GRPL-Latur)
400
GRPL (Latur) – Latur PS
220kV D/c line along with
associated line bays at both
ends M/C tower upto 2km. periphery from Latur
P.S.
GRPL / TBCB as per deliberations
in the meeting
6
Gamesha Renewable Pvt. Ltd. (GRPL-Tuljapur-Desingh)
400
GRPL (Tuljapur-Deosingh) – Latur PS 220kV D/c line along with associated line bays at both ends
GRPL / TBCB as per deliberations
in the meeting
7
Orange Ashok North Wind Power Pvt. Ltd. (OANWPPL-Lohara)
200
OANWPPL (Lohara) – Latur PS 220kV S/c line along with associated line bays at both ends
M/C tower upto 2km. periphery from Latur
P.S. or entire
common portion of
transmission line upto
Latur P.S.*
OANWPPL
8
Renew Wind Energy (AP2) Private Limited (RWEPL-Osmanabad)
400
RWEPL(Osmanabad) – Latur P.S. 220kV D/c line along with associated line bays at both ends
RWEPL / TBCB as per deliberations
in the meeting
9
Suzlon Power Infrastructure Limited (SPIL-Jevli)
300
SPIL(Jevli) – Latur P.S. 220kV
S/c line (high capacity twin
zebra equivalent) alongwith
associated line bays at both
ends
SPIL / TBCB as per
deliberations in the
meeting
*Based on GPS coordinates of the three RE projects, it is observed that most of the ROW upto Latur
P.S. of M/s OANWPPL-Lohara(200MW), M/s RWEPL-Osmanabad (400MW) and M/s SPIL-
Jevli(300MW) is common for dedicated connectivity lines of the wind farms. Accordingly, the common
portion of transmission line (starting from wind farm of M/s OANWPPL-Lohara) may be built using
Multi-circuit tower (such that it can accommodate 220kV D/c line of RWEPL(Osmanabad), 220kV S/c
line of SPIL-Jevli and 220kV S/c line of OANWPPL, Lohara). Alternatively, the dedicated connectivity
lines of the RE projects may be built individually and Multi-circuit towers shall be used for termination
into Latur P.S. (upto 2km periphery from Latur P.S).
Relative positioning of various RE projects getting pooled at Latur P.S. in Maharashtra can
be seen from the diagrams below:
Addl. Agenda of 24th Meeting of WR constituents for Connectivity & LTA applications
17
Annexure - I
Sl. No.
Generation Project LTA Application by CSPTrCL for its share
Revised LTA
requirement of CSPTrCL
(Petition) with Target beneficiary
in WR
TSA Signed
by CSPTrCL (Petition)
*
LTA quantum relinqushed by
CSPTrCL
BPTA Quantum
(MW)
Target/Firm Beneficiaries
(MW) Total WR NR
WR NR
A. BPTA & TSA signed by CSPTrCL for IPPs associated with HCTPC-V
1 RKM Powergen Ltd (4X360)
497 298 199 66 502 431 232 199
2 Athena Chhattisgarh Power Ltd. (2X600)
421 253 168 55 421 366 198 168
3 Jindal Power Ltd. (4X600)
769 461 308 110 769 659 351 308
4 Jindal Power Ltd. (400 MW)
0 0 0 0 0 0
5 SKS Power Gen. (Ch) Ltd. (4X300)
384 231 153 55 384 329 176 153
6 Korba West Power Co. Ltd. (1X600)
192 115 77 27 192 165 88 77
7 DB Power Ltd. (2X600) 384 231 153 55 384 329 176 153
8 KSK Mahanadi Power Co. Ltd. (6X600)
1153 692 461 82 1153 1071 610 461
9 Bharat Aluminium Co. Ltd. (4X300)
384 231 153 55 384 329 176 153
10 Vandana Vidyut Ltd. (2X135 + 1X270)
173 104 69 25 173 148 79 69
11 Lanco Amarkantak Power Pvt. Ltd. (2X660)
423 254 169 60 423 363 194 169
12 Chhattisgarh Steel & Power Ltd. (1x35 + 1x250 MW) (LTOA cancelled vide POWERGRID letter dated 01.07.2011)
91 55 36 0 91 91 55 36
Total 4871 2925 1946 590 4876 4281* 2335 1946
B. Only BPTA signed by CSPTrCL for IPPs associated with HCTPC-IV & Part System of HCTPC-I
1 Maruti Clean Coal & Power Ltd. (1x300 MW)
96 58 38 14 0 82 44 38
2 Dheeru Powergen Ltd. (3x300 MW)
336 202 134 0 0 336 202 134
Total 432 260 172 14 0 418* 246 172
C. Only TSA signed by CSPTrCL for IPPs associated with HCTPC-V
1 Visa Power Ltd. (1X600+1X660)
384 231 153 55 384 329 176 153
2 GMR Chhattisgarh Energy Pvt. Ltd. (2X685)
438 263 175 63 432 375 200 175
Total 822 494 328 118 816 704* 376 328
Grand Total 6125 3679 2446 722 5692 5403 2957 2446
LTA quantum relinquished by CSPTrCL:
As per BPTA singed by CSPTrCL : 4281 (A) + 418 (B) = 4699MW