r-21 emc 2012€¦ · 9.2. emission measurement: discontinuous disturbance 16 - 17 9.3. emission...

41
ELECTROMAGNETIC COMPATIBILITY TEST Report reference N° R-21 EMC 2012 Constructor .……………………………………………… Address …………………………………………………… Reference person………………………………………. A.S. Distribuzione S.r.l. Via Turati, 8 40134 Bologna Italy ---- Product ……….................………..........…………. Model ………………........................………………. Type …………………..…………………………….……. Serial number …………….....................………… Rating ……………......................………………….. Nebulizer Disinfectant for Surfaces 99.99M ---- M 17470392 230V ~ 50/60Hz 1000W Date of receipt of test item ................…………. Date of performance of test ................………… Date of test report …………..................…………. 05-01-12 11-01-12 ÷ 13-01-12 23-01-12 Reference standard ...........................…………. EN 55014-1: 2006 + A1: 2009 EN 55014-2: 1997 + A1: 2001 + A2: 2008 EN 61000-3-2: 2006 + A1: 2009 + A2: 2009 EN 61000-3-3: 2008 EN 61000-4-2: 2009 EN 61000-4-4: 2004 + A1: 2010 EN 61000-4-5: 2006 EN 61000-4-6: 2009 EN 61000-4-11: 2004 Final result COMPLIANT Compiled by Testing Engineer ……………………….…....…………… (Marco Casiraghi) Checked by …………………….…....…………… (Federico Sirtori) The test results recorded in this test report are exclusive referred to the tested samples. No part of this test report may be reproduced without prior written consent of Eletech. ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http:www.eletechsrl.it

Upload: others

Post on 27-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

ELECTROMAGNETIC COMPATIBILITY TEST

Report reference N° R-21 EMC 2012

Constructor .………………………………………………

Address ……………………………………………………

Reference person……………………………………….

A.S. Distribuzione S.r.l. Via Turati, 8 40134 Bologna Italy

----

Product ……….................………..........………….

Model ………………........................……………….

Type …………………..…………………………….……. Serial number …………….....................…………

Rating ……………......................…………………..

Nebulizer Disinfectant for Surfaces

99.99M

---- M 17470392

230V ~ 50/60Hz 1000W

Date of receipt of test item ................…………. Date of performance of test ................………… Date of test report …………..................………….

05-01-12 11-01-12 ÷ 13-01-12

23-01-12

Reference standard ...........................………….

EN 55014-1: 2006 + A1: 2009 EN 55014-2: 1997 + A1: 2001 + A2: 2008

EN 61000-3-2: 2006 + A1: 2009 + A2: 2009

EN 61000-3-3: 2008 EN 61000-4-2: 2009

EN 61000-4-4: 2004 + A1: 2010 EN 61000-4-5: 2006

EN 61000-4-6: 2009

EN 61000-4-11: 2004

Final result

COMPLIANT

Compiled by Testing Engineer

……………………….…....…………… (Marco Casiraghi)

Checked by

…………………….…....…………… (Federico Sirtori)

The test results recorded in this test report are exclusive referred to the tested samples. No part of this test report may be reproduced without prior written consent of Eletech.

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289

e-mail: [email protected] - http:www.eletechsrl.it

Page 2: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 2 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

1. Report index

Report index Page

1. Report index 2

2. General condition 3

3. Equipment under test 4 - 5

4. Test condition 6 - 7

5. Reference standard 8

6. Instruments 9

7. Uncertainty 10

8. Summary of result 11 - 12

9. Emission

9.1. Emission measurement: continuous disturbance 13 - 15

9.2. Emission measurement: discontinuous disturbance 16 - 17

9.3. Emission measurement: disturbance power 18 - 24

9.4. Emission measurement: electromagnetic radiation disturbance

9.5. Emission measurement: harmonics currents 25 - 27

9.6. Emission measurement: voltage fluctuation and flicker 28 - 29

10. Immunity

10.1. Immunity test: electrostatics discharger ESD 30 - 31

10.2. Immunity test: radiated RF electromagnetic field 32

10.3. Immunity test: electrical fast transients, burst 33

10.4. Immunity test: surge 34 - 35

10.5. Immunity test: conducted disturbance, induced RF field 36 - 37

10.6. Immunity test: voltage dips and short interruptions 38

11. Photo 39 - 40

12. Modify 41

Page 3: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 3 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

2. General condition

Objective The purpose of this tests, which are described in the present report, is to verify the conformity of

Equipment Under Test (E.U.T.) to the electromagnetic compatibility directive 2004/108/EC using harmonised standards.

Testing location

ELETECH S.r.l.

Via Garcia Lorca 29 23871 Lomagna (LC) Italy Department: Test Lab Centre

A company of Elemaster Group S.p.A.

Tested by

Mr. Casiraghi Marco

Witness to the test ----

Environment condition

Average values

Ambient temperature 15° - 35° 21°C

Humidity 25% - 75% 52% UR

Pressure 860 mbar - 1080 mbar 1010 mbar

Page 4: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 4 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

3. Equipment under test

Description The 99.99M is a Nebulizer Disinfectant for Surfaces.

The E.U.T. contains an electronic circuit of control with oscillator frequency lower than 15 MHz. It is used for domestic, commercial and light industrial environmental.

Type

99.99M

Identification sample tested

120001SAM00.00

Identification HW of E.U.T.

----

Identification SW of E.U.T. ----

Equipment classification Household appliances

Installation environment

Domestic, commercial and light industrial

Classification for RF emission test

EN 55014-1 Floor-standing equipment

Classification for RF immunity test

EN 55014-2 Reference 4 Apparatus of category II

Floor-standing equipment

Position of use Wall

Size (mm)

400 x 500 h 500

Page 5: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 5 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

3. Equipment under test

Page 6: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 6 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

4. Test condition

Set up during the test

Equipment Used During Test

Use Product Type Manufacturer Model Comments

E.U.T. Nebulizer Disinfectant for Surfaces

A.S. Distribuzione S.r.l.

99.99M ----

E.U.T.= Equipment Under Test AE= Auxiliary equipment

Rating

Mode Voltage (V)

Current (A)

Power (W)

Frequency (Hz)

Phase Comments

Rated 230 5 1000 50 1 Class 1 with earth

Enclosure

A.C. power supply

99.99M

Page 7: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 7 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

4. Test condition

Identification of Ports

Port # Name Type Cable

length > 3m

Shielded

Cable

Comments

1 Enclosure - - - Metallic and plastic structure

2 A.C. power supply

AC NO NO Cable 3 wire length 150 cm

AC= AC power port DC= DC power port

I/O= Signal Input or Output Port TP= Telecommunication Port

EUT Operation Mode

Mode # Description

1 Operation continuous of E.U.T.

2 Switch ON and operation continuous, for 24 measurements, Annex B EN 61000-3-3

EUT Configuration Mode

Mode # Description

1 Input power supply 230V

Requested performance for immunity test

The E.U.T. must continue to function (criterion A).

Control method for immunity test During the immunity test check:

• Nebulization

• Timer

Performance criteria of reference standard for immunity test EN 55014-2 reference 6

Generic performance criteria

Criterion A During testing, normal performance within the specification limits.

Criterion B During testing, temporary degradation, or loss of function or performance which is self-recovering.

Criterion C During testing, temporary degradation, or loss of function or performance which requires

operator intervention or system reset occurs.

Page 8: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 8 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

5. Reference standard

Standard Year Title

EN 55014-1

A1

2006

2009

Electromagnetic compatibility. Requirements for household appliances,

electric tools and similar apparatus. Part 1 : Emission. Product family standard.

EN 55014-2 A1

A2

1997 2001

2008

Electromagnetic compatibility. Requirements for household appliances, electric tools and similar apparatus.

Part 2 : Immunity. Product family standard.

EN 55016-2-3 2006 Specification for radio disturbance and immunity measuring apparatus

and methods - Part 2-3: Methods of measurement of disturbances and immunity –

Radiated disturbance measurements

EN 61000-3-2

A1 A2

2006

2009 2009

Electromagnetic compatibility (EMC)

Part 3-2: Limits Limits for harmonic current emission (equipment input current up to

and including 16 A per phase).

EN 61000-3-3 2008 Electromagnetic compatibility (EMC)

Part 3-3: Limits Limitation of voltage changes, voltage fluctuations and flicker in public

low-voltage supply systems, for equipment with rated current <= 16 A

per phase and not subject to conditional connection.

EN 61000-4-2

2009 Electromagnetic compatibility. Part 4: Testing and measuring

techniques. Section 2: Electrostatic discharge immunity test.

EN 61000-4-3 A1

2006 2008

Electromagnetic compatibility. Part 4: Testing and measuring techniques. Section 3: Radiated, radio-frequency, electromagnetic field

- Immunity test

EN 61000-4-4

A1

2004

2010

Electromagnetic compatibility. Part 4: Testing and measuring

techniques. Section 4: Electrical fast transient burst immunity test

EN 61000-4-5 2006 Electromagnetic compatibility. Part 4: Testing and measuring

techniques. Section 5: Surge immunity test

EN 61000-4-6 2009 Electromagnetic compatibility. Part 4: Testing and measuring

techniques. Section 6: Immunity to conducted disturbance, induced by radio-frequency fields.

EN 61000-4-11 2004 Electromagnetic compatibility. Part 4: Testing and measuring techniques. Section 11: Voltage dips, short interruptions and voltage

variations immunity test.

Page 9: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 9 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

6. Instrument

Calibration instrument

Description Model Serial number Manufacturer Due date

ALI014 Power Supply PAS5000 A182601-01096 Spitzenberger+Spies 15/07/2012

AMP001 Amplifier 75A250 19666 Amplifier Research 15/07/2012 AMP002 Amplifier 100W1000M1 18650 Amplifier Research 15/07/2012 AMP003 Amplifier 30S1G3 300786 Amplifier Research 15/07/2012 AMP004 Amplifier 150A400 0330804 Amplifier Research 15/07/2012 CAM006 Semi Anechoic Chamber 3mSAC B83117-S20-X435 Albatross Projects 02/03/2014

GDF001 Signal generator HP33120A US36010500 HP 15/07/2012 GEN001 Dips generator PFS500 0296-04 EM Test 15/07/2012 GEN004 Surge generator VCS500 0995-03 EM Test 15/07/2012 GEN005 Signal generator SML03 100162 Rohde & Schwarz 15/07/2012 GEN006 Burst generator EFT 500 M4 V0712102348 EM Test 15/07/2012 GEN007 Signal generator SyCore PC/104 A3986 12/0 0507 Spitzenberger+Spies 15/07/2012 GEN008 ESD generator ESD30N V0930105020 EM Test 15/07/2012 IGR001 Humidity sensor Igrometro da parete 0 Johnson Controls 15/07/2012 MDC001 Field probe PM2002 26698 Amplifier Research 03/08/2012

MDC002 Laser Probe Interface FI7000 0332975

S/N Kit: 0333300 Amplifier Research 03/08/2012

MDC003 Laser powered field probe FL7006 Start Probe 2

100kHz - 6GHz 0332632

S/N Kit: 0333300 Amplifier Research 03/08/2012

PAS001 Coupling / Decoupling CDN M1 12039 MEB 15/07/2012 PAS002 Coupling / Decoupling CDN M2 12096 MEB 15/07/2012 PAS003 Coupling / Decoupling CDN M3 12859 MEB 15/07/2012 PAS004 Coupling / Decoupling CDN M4 00265 Eletech 15/07/2012 PAS005 Coupling / Decoupling CDN M5 00266 Eletech 15/07/2012 PAS006 Unidirectional coupling DC7144 300678 Amplifier Research 15/07/2012 PAS009 Antenna 3115 9005-3475 EMCO 26/07/2013

PAS010 LISN - Artificial mains

network ESH2-Z5 830364/008 Rohde & Schwarz

15/07/2012

PAS011 LISN ESH3-Z6 833772-010 Rohde & Schwarz 15/07/2012 PAS012 LISN ESH3-Z6 833772-011 Rohde & Schwarz 15/07/2012 PAS013 LISN ESH3-Z6 833772-009 Rohde & Schwarz 15/07/2012 PAS014 Absorbing clamp MDS 21 830409/013 Rohde & Schwarz 15/07/2012 PAS015 Burst clamp 1 METRO 00438 EM Test 15/07/2012 PAS016 RF clamp F-203I 229 FCC 04/08/2013

PAS018 Antenna Loop 2 METRI 5134 Teseo 15/07/2012 PAS020 Induction coil 50Hz 1 METRO - Eletech 15/07/2012 PAS021 Attenuator Attenuatore 6dB - TESEO 15/07/2012 PAS022 Unidirectional coupling DC6180 19593 Amplifier Research 15/07/2012 PAS023 Reference impedence IEC 725 00355 Eletech 15/07/2012 PAS024 Coupling CDN-S1 - Eletech 15/07/2012 PAS025 Coupling CDN-S1 - Eletech 15/07/2012

PAS026 Coupling / Decoupling

network for surge CDN-S 1000-4-5 - -

15/07/2012

PAS028 Antenna - Trilog Super VULB 9161SE

(25MHz - 2GHz) 9161-4084

Schwarzbeck Mess - Elektronik

03/08/2012

PAS032 Attenuator 3dB 6803.17.AC

Per Emissione Radiata - Huber+Suhner

15/07/2012

PAS034 Attenuator 6N10W - 30dB 6N10W-30 D.S.P.M.

Telecomunicazioni 15/07/2012

PAS035 Attenuator 6N - 10dB 6N10 D.S.P.M.

Telecomunicazioni 15/07/2012

PAS036 Unidirectional coupling C1795-13 38624 Werlatone 15/07/2012

Page 10: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 10 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

6. Instrument

Calibration instrument

Description Model Serial number Manufacturer Due date

PAS037 Attenuator 6dB 6806.17.AC

- Huber+Suhner

15/07/2012

PAS039 Coupling / Decoupling

network for burst CDN-B 1000-4-4 - -

15/07/2012

PAS040 Coupling 0,47uF+ 40 ohm

for surge CDN-C 1000-4-5 - Eletech

15/07/2012

PAS041 Decoupling for surge CDN-C 1000-4-5 - Eletech 15/07/2012

PAS042 ISN for emission on LAN

cable

NTFM 8158 ISN CAT6 - 8 wire

150kHz - 30MHz 8158-0006

Schwarzbeck Mess - Elektronik

15/07/2012

PAS043 Antenna VULP 9118 E

Log.-Per. 75MHz - 1500MHz

9118E867 Schwarzbeck

Mess - Elektronik 02/05/2013

PAS044 Unidirectional coupling DC3400A

40dB 200W 10kHz - 400MHz

0332124 Amplifier Research 15/07/2012

SON001 RF sensor + attenuator +

voltage probe ESH2-Z3 299.7810.52 Rohde & Schwarz 15/07/2012

SON004 Power head PH2000 27478 Amplifier Research 03/08/2012

SON005 Power head PH2000 301205 Amplifier Research 15/07/2012 SON007 Current Probe ESH2-Z1 830260/20 Rohde & Schwarz 15/07/2012 TER004 Temperature sensor RS9140-0000 1 Johnson Controls 15/07/2012 TES008 EMI Test Receiver ESVS 10 825892/002 Rohde & Schwarz 15/07/2012 TES009 EMI Test Receiver ESHS 10 830051/010 Rohde & Schwarz 15/07/2012

TES011 Harmonic and Flicker

measurement PMM1000 M50513 BO CONSULT

15/07/2012

TES019 Clickmeter Chase London

SW147LY 1512 - 0190

5033 Chase Electronics LTD 15/07/2012

TES020 EMI Test Receiver ESCI 7 100755 Rohde & Schwarz 15/07/2012

Page 11: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 11 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

7. Uncertainty

Test Reference standard Parameter Uncertainty

Measure of harmonic current

IEC 1000-3-2 Harmonic current measurement 0,11%

Voltage measurement 0,22%

EN 61000-3-2 Frequency 0,01%

Measure of mains harmonic voltage 0,06%

Measure of flickers

IEC 1000-3-3

Voltage measurement 0,22%

Frequency 0,01%

Measure of mains harmonic voltage 0,06%

EN 61000-3-3

Impedance 6,40%

Pst 4,89%

dc 0,21%

dmax, dt 0,20%

Measure of radiated emission CISPR 11 – EN 55011 Measured field (horizontal) 4.90 dB

CISPR 22 – EN 55022 Measured field (vertical) 4.93 dB

Measure of continuous emission disturbance

CISPR 11 – EN 55011

Measured voltage 2.60 dB CISPR 14 – EN 55014-1

CISPR 15 – EN 55015

CISPR 22 – EN 55022

Measure of common mode conducted emission CISPR 22 – EN 55022 Measured voltage 2.85 dB

Measure of conducted emission at terminals CISPR 14-1 – EN 55014-1

Measured voltage 2.60 dB CISPR 11 – EN 55011

Measure of disturbance power CISPR 14 – EN 55014-1 Measured power 2.78 dB

Measure of radiated electromagnetic disturbance

CISPR 15 – EN 55015 Measured field 4.12 dB

Immunity to electrostatic discharge IEC 1000-4-2 The generator meets the tolerance requirements of

EN 61000-4-2 EN 61000-4-2

Immunity to radiated immunity IEC 1000-4-3

Radiated field 2.38 dB EN 61000-4-3

Immunity to burst IEC 1000-4-4 The generator meets the tolerance requirements of

EN 61000-4-4 EN 61000-4-4

Immunity to surge IEC 1000-4-5 The generator meets the tolerance requirements of

EN 61000-4-5 EN 61000-4-5

Immunity to induced RF field IEC 1000-4-6 Applied field (CDN) 1.02 dB

EN 61000-4-6 Applied field (EM-Clamp) 2.23 dB

Immunity to magnetic field at 50Hz IEC 1000-4-8 The generator meets the tolerance requirements of

EN 61000-4-8 EN 61000-4-8

Immunity to voltage dips IEC 1000-4-11 The generator meets the tolerance requirements of

EN 61000-4-11 EN 61000-4-11

The measurement uncertainties stated in this documents are estimated as extended uncertainty obtained multiplying the standard uncertainty by the coverage factor k corresponding to a confidence level of about 95%..

Page 12: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 12 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

8. Result summary

Emission requirements according to

EN 55014-1: 2006 + A1: 2009

Port Test Standard / Limit Result

A.C. power supply Emission measurement: continuous disturbance

EN 55014-1 Table 1 PASS

A.C. power supply Emission measurement: discontinuous disturbance

EN 55014-1 Table 1 PASS

A.C. power supply Emission measurement: disturbance power

EN 55014-1 Table 2a PASS

A.C. power supply Emission measurement:

disturbance power

EN 55014-1 Table 2b PASS

Enclosure Radiated emission:

continuous interference

EN 55014-1 Table 3 Not applicable

Emission requirements according to EN 61000-3-2: 2006 + A1: 2009 + A2: 2009

Port Test Standard / Limit Result

A.C. power supply Emission measurement:

harmonics currents

EN 61000-3-2 Class A

PASS

Emission requirements according to

EN 61000-3-3: 2008

Port Test Standard / Limit Result

A.C. power supply Emission measurement:

voltage fluctuation and flicker

EN 61000-3-3

PASS

Page 13: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 13 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

8. Result summary

Immunity requirements according to

EN 55014-2: 1997 + A1: 2001 + A2: 2008

Port Test Standard / Level Compliance

criterion

Result

Enclosure Electrostatic discharge (ESD) – indirect on coupling plane with

contact discharge – direct on case with air and

contact discharge

EN 61000-4-2 ± 4 kV Cont.

± 8 kV Air

B

PASS

Enclosure Radiated electromagnetic field

80 - 1000 MHz, 80%AM (1kHz)

EN 61000-4-3

3 V/m

A

Not applicable for apparatus of category II

A.C. power

supply

Fast Transients (EFT)

Common Mode, 5/50ns, Repetition frequency 5kHz

EN 61000-4-4

± 1 kV

B

PASS

A.C. power supply

Slow transients (Surges) Pulse form 1.2/50 µs

EN 61000-4-5 ± 1 kV MD

± 2 kV MC

B

PASS

A.C. power

supply

Conducted radio frequency

150 kHz - 80 MHz, 1kHz 80% AM, 150Ω source imp.

EN 61000-4-6

3 V

A

Not applicable for apparatus of category II

A.C. power supply

Conducted radio frequency 150 kHz - 230 MHz, 1kHz 80%

AM, 150Ω source imp.

EN 61000-4-6 3 V

A

PASS

A.C. power

supply

Voltage interruption

Test level in % Ut

EN 61000-4-11

0% 10ms

B

PASS

A.C. power

supply

Voltage interruption

Test level in % Ut

EN 61000-4-11

40% 200ms

C

PASS

A.C. power

supply

Voltage interruption

Test level in % Ut

EN 61000-4-11

70% 500ms

C

PASS

Page 14: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 14 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

9.1. Emission measurement: continuous disturbance

Test Measurement of mains terminal disturbance. Continuous disturbance

Reference standard EN 55014-1 Reference 5

EUT operation mode # 1

EUT configuration mode # 1

Port A.C. power supply

Verdict

COMPLIANT

Limits table 1

Frequency band (MHz) Quasi-peak (dB µV) Average (dB µV)

0.15 - 0.5 66 - 56 59 - 46

0.5 - 5 56 46

5 - 30 60 50

Test equipment

Equipment Model Manufacturer Serial number

Shielded chamber Siemens

Receiver ESHS 10 R&S 830051/010

Artificial main network ESH2-Z5 R&S 830364/008

Page 15: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 15 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

9.1. Emission measurement: continuous disturbance ELETECH S.r.l. Conducted emission EUT: 99.99M Manufacturer: A.S. DISTRIBUZIONE Operating Condition: Continuous operation Test Site: Shielded chamber Operator: Casiraghi Test Specification: EN 55014-1 Comment: New EMI Filter 11-01-2012 SCAN TABLE: "ET QP Voltage + 6dB" Short Description: EN 55022 Voltage pr e Start Stop Step Detector Meas. IF Transducer Frequency Frequency Width Time Bandw. 150.0 kHz 30.0 MHz 8.0 kHz QuasiPeak 1.0 s 10 kHz Att. 6dB Average

-10

0

10

20

30

40

50

60

70

Level [dBµV]

150k 300k 500k 1M 2M 3M 5M 7M 10M 30MFrequency [Hz]

x x x

x

x MES 120001b_fin MES 120001b_pre MES 120001b_pre2 LIM EN 55014 V QP Voltage QPLIM EN 55014 V AV Voltage AV

Page 16: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 16 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

9.1. Emission measurement: continuous disturbance

MEASUREMENT RESULT: "120001b_fin" 02/01/80 0.18 Frequency Level Transd Limit Margin Detec tor Line PE MHz dBµV dB dBµV dB 0.190000 53.60 6.0 64 10.4 QP L1 GND 0.286000 52.30 6.0 61 8.3 QP L1 GND 0.318000 51.20 6.0 60 8.6 QP L1 GND 0.454000 40.10 6.0 57 16.7 QP L1 GND

Page 17: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 17 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

9.2. Emission measurement: discontinuous disturbance

Test Measurement of mains terminal disturbance.

Discontinuous disturbance

Reference standard EN 55014-1

EUT operation mode # 1

EUT configuration mode # 1

Port A.C. power supply

Verdict

COMPLIANT

Limits table 1

Frequency band (MHz) Quasi-peak (dB µV) Average (dB µV)

0.15 - 0.5 66 - 56 59 - 46

0.5 - 5 56 46

5 - 30 60 50

Test equipment

Equipment Model Manufacturer Serial number

Shielded chamber Siemens

Clickmeter DIA 1512 Chase 5107

Receiver ESHS 10 R&S 83005/010

Artificial main network ESH2-Z5 R&S 830364/008

Page 18: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 18 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

9.2. Emission measurement: discontinuous disturbance

Frequency

(MHz)

f 0.15 0.50 1.4 30

Continuous limit (dBµV)

L 66 56 56 60

Time T 120 120 120 120 Counted click (N) (short <= 10ms )

NA 0 0 0 0

Counted click (N) (short > 20ms )

NA 0 0 0 0

Counted click

(N) (long)

NB 0 0 0 0

Counted click

(N)

N1(1)

Click frequency (N/ min)

N(2)

Continuous d(3)

More than 2 clicks in 2 sec

New limit

(dBµV)

LQ(4) - - - -

Number of

clicks over LQ

(short)

NA

Number of

clicks over LQ (long)

NB

Number of

clicks over LQ

N2

Percentage (%)

N2/n1(5)

Final result Compliant Compliant Compliant Compliant

(1) : minimum 40 clicks or 120 min. of testing time

(2) : K*n1/T with =0.66sec (3) : maximum acceptable limit of 0.6sec

(4) : LQ=L + 20Log (30/N) (0.2<N<30) ; LQ= L + 44(N<0.2)

(5) : n2/n1 %< (or=) 25

Page 19: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 19 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

9.3. Emission measurement: disturbance power

Test Measurement of mains terminal disturbance.

Disturbance power

Reference standard EN 55014-1 Reference 6

EUT operation mode # 1

EUT configuration mode # 1

Port A.C. power supply

Verdict

COMPLIANT

Limits table 2

Frequency band (MHz) Quasi-peak (dB pW) Average (dB pW)

30 - 300 45 - 55 35 - 45

Test equipment

Equipment Model Manufacturer Serial number

Semi Anechoic Chamber 3m SAC Albatros Projects

Clamp MDS 21 R&S 830409/013

Receiver ESVS 10 R&S 825892/002

Page 20: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 20 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

9.3. Emission measurement: disturbance power

Page 21: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 21 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

9.3. Emission measurement: disturbance power

Page 22: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 22 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

9.3. Emission measurement: disturbance power

Page 23: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 23 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

9.4. Emission measurement: electromagnetic radiation disturbance

Test Radiated emission: continuous interference

Reference standard EN 55014-1 + A1 Reference 9 EN 55016-2-3

EUT operation mode # 1

EUT configuration mode # 1

Port Enclosure

Verdict

NOT APPLICABLE

Limit table 3

Frequency band (MHz) Quasi-peak (dB µV/m)

30 - 230 30

> 230 - 1000 37

The limits are increased by a factor of 10 dB for the measuring distance of 3 m

Limit table 2a

Frequency band (MHz) Quasi-peak (dB pW)

30 - 300 45 - 55

Limit table 2b

Frequency range Margin

200 - 300 0 to 10 dB

Test equipment

Equipment Model Manufacturer Serial number

Semi Anechoic Chamber 3mSAC Albatros Project

Receiver ESCI 7 R&S 100755

Antenna VULB 9161 SE SCHWARZBECK 9161-4084

In according to EN 55014-1 reference 4.1.2.3.2, the measure in the frequency range from 300MHz to 1000MHz are not applicable because the EUT is comply at following condition:

1) All emission readings from the equipment under test shall be lower than the applicable limits

(Table 2a) reduced by the margin (Table 2b);

2) The maximum clock frequency shall be less than 30 MHz.

Page 24: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 24 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

9.5. Emission measurement: harmonics currents

Test Measurement of harmonics current injected into public supply system.

Reference standard EN 61000-3-2

Reference 6 Class A equipment

EUT operation mode # 1

EUT configuration mode # 1

Port A.C. power supply

Verdict

COMPLIANT

Limits table 1

Number Harmonics Max harmonics current (A)

Odd harmonics

3 2,3

5 1,14

7 0,77

9 0,4

11 0,33

13 0,21

15 <= n <= 39 0,15 x (15/n)

Even harmonics

2 1,08

4 0,43

6 0,30

8 <= n <= 40 0,8 x (8/n)

Test equipment

Equipment Model Manufacturer Serial number

Harmonics analyser and

flickermeter

B10 / PMM1000 PMM M50513

A.C. Power PAS 5000 SPITZENBERGER A182601/01096

Page 25: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 25 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

9.5. Emission measurement: harmonics currents

EUT operation mode #1 (Harmonics current)

Name: Casiraghi Serial no: ----

Department: Test Lab Centre Operating modes: Normal operation

Company: ELETECH S.r.l. Comment1:

Test report no: 120001 Comment2:

Device: Sterilizzatore di ambient Comment3:

Specimen: EN 61000-3-2 Comment4:

Manufacturer: A.S. DISTR. LA FUCINA Date: 12.01.2012

Type: 99.99 M Test date: 12.01.2012

Maximum RMS current and corresponding values in timewindow 4:

Voltage:

Current:

Power:

Power factor:

Test conditions:

229.81 Vrms

4.816 Arms

1041.5 W

0.941

EN 61000-3-2:2006 + A1:2009 + A2:2009, f=50 Hz, Phase=L1, Range=20.00 A

Time window=10/12 (200ms), Grouping (>2nd harm.)=on

No Ztest selected

harmonic cur. < 0.6 % of I or < 5 mA are NOT DISREGARD for calc. of THD, THC, POHC, PWHD

P1=1041.6 W

CosPhi1: 0.973

THD=0.05 %

THD=26.43 %

1106.8 VA

THV=0.116 V

THC=1.231 A

POHV=0.008 V

POHC=0.020 A

PWHD=0.03 %

PWHD=3.76 %

Entire measurement (30.000 s = 150 time window(s)) Worst 2.5 min Average PASS

FAIL

Ha Maximum Window EN61000-3-2

Class A

Margin

in MaxWin

100 to

150%

150 to

200%

Ex-

ceeded

100 to

150%

Ex-

ceeded

Value Ex-

ceeded

DC 0.0462 A 46 -.- - - - - - - . - 0 0 0 n.e. n.e. 0.0357 A 0 X

1 4.6561 A 4 -.- - - - - - - . - 0 0 0 n.e. n.e. 4.4904 A 0 X

2 0.0141 A 149 1.0800 A -98.7 % 0 0 0 n.e. n.e. 0.0104 A 0 X

3 1.2352 A 52 2.3000 A -46.3 % 0 0 0 n.e. n.e. 1.2305 A 0 X

4 0.0121 A 103 0.4300 A -97.2 % 0 0 0 n.e. n.e. 0.0107 A 0 X

5 0.0721 A 149 1.1400 A -93.7 % 0 0 0 n.e. n.e. 0.0615 A 0 X

6 0.0172 A 5 0.3000 A -94.3 % 0 0 0 n.e. n.e. 0.0137 A 0 X

7 0.0905 A 150 0.7700 A -88.2 % 0 0 0 n.e. n.e. 0.0887 A 0 X

8 0.0159 A 133 0.2300 A -93.1 % 0 0 0 n.e. n.e. 0.0118 A 0 X

9 0.0198 A 11 0.4000 A -95.1 % 0 0 0 n.e. n.e. 0.0174 A 0 X

10 0.0130 A 139 0.1840 A -92.9 % 0 0 0 n.e. n.e. 0.0097 A 0 X

11 0.0181 A 149 0.3300 A -94.5 % 0 0 0 n.e. n.e. 0.0156 A 0 X

12 0.0496 A 87 0.1533 A -67.7 % 0 0 0 n.e. n.e. 0.0427 A 0 X

13 0.0141 A 122 0.2100 A -93.3 % 0 0 0 n.e. n.e. 0.0107 A 0 X

14 0.0438 A 90 0.1314 A -66.7 % 0 0 0 n.e. n.e. 0.0372 A 0 X

15 0.0136 A 125 0.1500 A -90.9 % 0 0 0 n.e. n.e. 0.0093 A 0 X

16 0.0100 A 41 0.1150 A -91.3 % 0 0 0 n.e. n.e. 0.0086 A 0 X

17 0.0075 A 1 0.1324 A -94.4 % 0 0 0 n.e. n.e. 0.0056 A 0 X

18 0.0058 A 147 0.1022 A -94.4 % 0 0 0 n.e. n.e. 0.0046 A 0 X

19 0.0073 A 73 0.1184 A -93.9 % 0 0 0 n.e. n.e. 0.0058 A 0 X

20 0.0047 A 136 0.0920 A -94.9 % 0 0 0 n.e. n.e. 0.0038 A 0 X

21 0.0111 A 36 0.1071 A -89.6 % 0 0 0 n.e. n.e. 0.0078 A 0 X

22 0.0044 A 106 0.0836 A -94.8 % 0 0 0 n.e. n.e. 0.0036 A 0 X

23 0.0078 A 31 0.0978 A -92.0 % 0 0 0 n.e. n.e. 0.0067 A 0 X

24 0.0061 A 1 0.0767 A -92.0 % 0 0 0 n.e. n.e. 0.0040 A 0 X

25 0.0238 A 150 0.0900 A -73.6 % 0 0 0 n.e. n.e. 0.0154 A 0 X

26 0.0056 A 1 0.0708 A -92.0 % 0 0 0 n.e. n.e. 0.0034 A 0 X

27 0.0284 A 86 0.0833 A -65.9 % 0 0 0 n.e. n.e. 0.0213 A 0 X

28 0.0057 A 109 0.0657 A -91.3 % 0 0 0 n.e. n.e. 0.0046 A 0 X

29 0.0053 A 50 0.0776 A -93.1 % 0 0 0 n.e. n.e. 0.0048 A 0 X

30 0.0052 A 14 0.0613 A -91.5 % 0 0 0 n.e. n.e. 0.0037 A 0 X

31 0.0039 A 130 0.0726 A -94.6 % 0 0 0 n.e. n.e. 0.0030 A 0 X

32 0.0079 A 34 0.0575 A -86.3 % 0 0 0 n.e. n.e. 0.0060 A 0 X

33 0.0034 A 105 0.0682 A -95.0 % 0 0 0 n.e. n.e. 0.0029 A 0 X

34 0.0082 A 23 0.0541 A -84.8 % 0 0 0 n.e. n.e. 0.0049 A 0 X

35 0.0029 A 95 0.0643 A -95.5 % 0 0 0 n.e. n.e. 0.0024 A 0 X

36 0.0056 A 90 0.0511 A -89.1 % 0 0 0 n.e. n.e. 0.0042 A 0 X

37 0.0034 A 43 0.0608 A -94.4 % 0 0 0 n.e. n.e. 0.0030 A 0 X

38 0.0181 A 87 0.0484 A -62.6 % 0 0 0 n.e. n.e. 0.0123 A 0 X

39 0.0147 A 36 0.0577 A -74.6 % 0 0 0 n.e. n.e. 0.0078 A 0 X

40 0.0119 A 148 0.0460 A -74.2 % 0 0 0 n.e. n.e. 0.0075 A 0 X

HARMONIC ANALYSIS: Test PASS

Tobs = entire measurement; POHC: avg=0.03 A, limits=0.25 A

Iavg=4.658 Arms

Tested with SPS EMC 3.0.4 / None by Spitzenberger & Spies GmbH & Co. KG, Schmidstr. 32-34, 94234 Viechtach, Germany, 12.01.2012

average value < 0.6 % of Iavg or < 5 mA

Page 26: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 26 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

9.5. Emission measurement: harmonics currents

EUT operation mode #1 (Harmonics voltage)

Name: Casiraghi Serial no: ----

Department: Test Lab Centre Operating modes: Normal operation

Company: ELETECH S.r.l. Comment1:

Test report no: 120001 Comment2:

Device: Sterilizzatore di ambient Comment3:

Specimen: EN 61000-3-2 Comment4:

Manufacturer: A.S. DISTR. LA FUCINA Date: 12.01.2012

Type: 99.99 M Test date: 12.01.2012

Maximum RMS current and corresponding values in timewindow 4:

Voltage:

Current:

Power:

Power factor:

Test conditions:

229.81 Vrms

4.816 Arms

1041.5 W

0.941

EN 61000-3-2:2006 + A1:2009 + A2:2009, f=50 Hz, Phase=L1, Range=20.00 A

Time window=10/12 (200ms), Grouping (>2nd harm.)=on

No Ztest selected

harmonic cur. < 0.6 % of I or < 5 mA are NOT DISREGARD for calc. of THD, THC, POHC, PWHD

P1=1041.6 W

CosPhi1: 0.973

THD=0.05 %

THD=26.43 %

1106.8 VA

THV=0.116 V

THC=1.231 A

POHV=0.008 V

POHC=0.020 A

PWHD=0.03 %

PWHD=3.76 %

Entire measurement (30.000 s = 150 time window(s)) Worst 2.5 min Average PASS

FAIL

Ha Maximum Window EN61000-3-2

Voltages

Margin

in MaxWin

100 to

150%

Ex-

ceeded

100 to

150%

Ex-

ceeded

Value Ex-

ceeded

DC 0.0097 V 72 -.- - - - - - - . - - - - 0 n.e. n.e. 0.0035 V 0 X

1 229.8466 V 145 -.- - - - - - - . - - - - 0 n.e. n.e. 229.8320 V 0 X

2 0.0288 V 145 fluctuating -93.7 % - - - 0 n.e. n.e. 0.0218 V 0 X

3 0.1190 V 149 fluctuating -94.2 % - - - 0 n.e. n.e. 0.1125 V 0 X

4 0.0084 V 150 fluctuating -98.2 % - - - 0 n.e. n.e. 0.0065 V 0 X

5 0.0106 V 150 fluctuating -98.9 % - - - 0 n.e. n.e. 0.0078 V 0 X

6 0.0064 V 147 fluctuating -98.6 % - - - 0 n.e. n.e. 0.0040 V 0 X

7 0.0163 V 131 fluctuating -97.6 % - - - 0 n.e. n.e. 0.0129 V 0 X

8 0.0058 V 147 fluctuating -98.7 % - - - 0 n.e. n.e. 0.0040 V 0 X

9 0.0037 V 145 fluctuating -99.2 % - - - 0 n.e. n.e. 0.0024 V 0 X

10 0.0053 V 99 fluctuating -98.8 % - - - 0 n.e. n.e. 0.0041 V 0 X

11 0.0032 V 30 fluctuating -98.6 % - - - 0 n.e. n.e. 0.0024 V 0 X

12 0.0061 V 148 fluctuating -97.3 % - - - 0 n.e. n.e. 0.0038 V 0 X

13 0.0028 V 115 fluctuating -98.8 % - - - 0 n.e. n.e. 0.0014 V 0 X

14 0.0053 V 102 fluctuating -97.7 % - - - 0 n.e. n.e. 0.0032 V 0 X

15 0.0053 V 149 fluctuating -97.7 % - - - 0 n.e. n.e. 0.0041 V 0 X

16 0.0026 V 102 fluctuating -98.9 % - - - 0 n.e. n.e. 0.0017 V 0 X

17 0.0038 V 143 fluctuating -98.3 % - - - 0 n.e. n.e. 0.0030 V 0 X

18 0.0017 V 139 fluctuating -99.2 % - - - 0 n.e. n.e. 0.0011 V 0 X

19 0.0056 V 149 fluctuating -97.6 % - - - 0 n.e. n.e. 0.0045 V 0 X

20 0.0017 V 146 fluctuating -99.3 % - - - 0 n.e. n.e. 0.0010 V 0 X

21 0.0031 V 150 fluctuating -98.7 % - - - 0 n.e. n.e. 0.0014 V 0 X

22 0.0019 V 144 fluctuating -99.2 % - - - 0 n.e. n.e. 0.0013 V 0 X

23 0.0024 V 95 fluctuating -99.0 % - - - 0 n.e. n.e. 0.0017 V 0 X

24 0.0023 V 36 fluctuating -99.0 % - - - 0 n.e. n.e. 0.0015 V 0 X

25 0.0051 V 145 fluctuating -97.8 % - - - 0 n.e. n.e. 0.0023 V 0 X

26 0.0013 V 150 fluctuating -99.4 % - - - 0 n.e. n.e. 0.0008 V 0 X

27 0.0044 V 130 fluctuating -98.1 % - - - 0 n.e. n.e. 0.0021 V 0 X

28 0.0013 V 34 fluctuating -99.4 % - - - 0 n.e. n.e. 0.0007 V 0 X

29 0.0022 V 139 fluctuating -99.0 % - - - 0 n.e. n.e. 0.0009 V 0 X

30 0.0018 V 18 fluctuating -99.2 % - - - 0 n.e. n.e. 0.0009 V 0 X

31 0.0033 V 2 fluctuating -98.5 % - - - 0 n.e. n.e. 0.0026 V 0 X

32 0.0018 V 24 fluctuating -99.2 % - - - 0 n.e. n.e. 0.0008 V 0 X

33 0.0031 V 123 fluctuating -98.6 % - - - 0 n.e. n.e. 0.0022 V 0 X

34 0.0015 V 15 fluctuating -99.3 % - - - 0 n.e. n.e. 0.0007 V 0 X

35 0.0044 V 53 fluctuating -98.1 % - - - 0 n.e. n.e. 0.0038 V 0 X

36 0.0014 V 100 fluctuating -99.4 % - - - 0 n.e. n.e. 0.0007 V 0 X

37 0.0052 V 1 fluctuating -97.7 % - - - 0 n.e. n.e. 0.0042 V 0 X

38 0.0031 V 148 fluctuating -98.7 % - - - 0 n.e. n.e. 0.0009 V 0 X

39 0.0022 V 140 fluctuating -99.0 % - - - 0 n.e. n.e. 0.0015 V 0 X

40 0.0023 V 146 fluctuating -99.0 % - - - 0 n.e. n.e. 0.0008 V 0 X

HARMONIC ANALYSIS: Test PASS

Tobs = entire measurement; POHC: avg=0.01 V, limits=0.73 V

Vavg=229.83 Vrms

Tested with SPS EMC 3.0.4 / None by Spitzenberger & Spies GmbH & Co. KG, Schmidstr. 32-34, 94234 Viechtach, Germany, 12.01.2012

Page 27: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 27 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

9.6. Emission measurement: voltage fluctuation and flicker

Test Measurement of voltage fluctuation and flicker injected into public

supply system.

Reference standard EN 61000-3-3

EUT operation mode # 2

EUT configuration mode # 1

Port A.C. power supply

Verdict

COMPLIANT

Limits

Condition # Measuring

time

PLT PST dt dmax dc

2 24 x 1min. - - 3,3% for

more than

500mS

7% of Ut 3,3% of Ut

Ut = power supply of E.U.T. (230V c.a.) Plt = The flicker severity evaluated over a long period (a few hours) using successive Pst values. Pst = The flicker severity evaluated over a short period (in minutes)Pst=1 is the conventional threshold of irritability. Dt = The time function of the change in the r.m.s. voltage between periods when the voltage is in a steady-state condition for at least 1 s. Dmax = The difference between maximum and minimum r.m.s. values of the voltage change characteristics. Dc = The difference between two adjacent steady-state voltage separated by at least one voltage change characteristics.

Test equipment

Equipment Model Manufacturer Serial number

Harmonics analyser and

flickermeter

B10 / PMM1000 PMM M50513

A.C. Power PAS 5000 SPITZENBERGER A182601/01096

Page 28: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 28 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

9.6. Emission measurement: voltage fluctuation and flicker

Name: Casiraghi Serial no: ----

Department: Test Lab Centre Operating modes: Normal operation

Company: ELETECH S.r.l. Comment1:

Test report no: 120001 Comment2:

Device: Sterilizzatore di ambient Comment3:

Specimen: EN 61000-3-2 Comment4:

Manufacturer: A.S. DISTR. LA FUCINA Date: 12.01.2012

Type: 99.99 M Test date: 12.01.2012

Test conditions: EN 61000-3-3:2008 / 229 V / 50 Hz / Phase L1 /

Obs cont. mode / Ztest (0.400+j0.250) Ohm

Time Pmax Pst Sliding Plt d(t)>3.30% [s] dmax [%] dc [%] PASS FAIL

09:48:26 - . - - - - . - - - - - . - - - - 0.090 4.692 0.956 X

09:49:22 - . - - - - . - - - - - . - - - - 0.090 4.672 - . - - - X

09:50:22 - . - - - - . - - - - - . - - - - 0.090 4.356 0.926 X

09:51:06 - . - - - - . - - - - - . - - - - 0.090 4.486 - . - - - X

09:51:46 - . - - - - . - - - - - . - - - - 0.090 4.813 - . - - - X

09:52:30 - . - - - - . - - - - - . - - - - 0.090 4.862 0.949 X

09:53:26 - . - - - - . - - - - - . - - - - 0.090 4.779 0.932 X

09:54:26 - . - - - - . - - - - - . - - - - 0.095 4.778 0.933 X

09:55:06 - . - - - - . - - - - - . - - - - 0.080 4.368 - . - - - X

09:55:54 - . - - - - . - - - - - . - - - - 0.090 4.824 - . - - - X

09:56:46 - . - - - - . - - - - - . - - - - 0.080 4.396 0.929 X

09:57:38 - . - - - - . - - - - - . - - - - 0.090 4.451 0.938 X

09:58:26 - . - - - - . - - - - - . - - - - 0.090 4.754 - . - - - X

09:59:18 - . - - - - . - - - - - . - - - - 0.080 4.416 0.940 X

10:00:10 - . - - - - . - - - - - . - - - - 0.090 4.456 0.935 X

10:00:50 - . - - - - . - - - - - . - - - - 0.090 4.538 - . - - - X

10:01:34 - . - - - - . - - - - - . - - - - 0.090 4.703 0.941 X

10:02:42 - . - - - - . - - - - - . - - - - 0.090 4.506 0.938 X

10:03:42 - . - - - - . - - - - - . - - - - 0.080 4.320 0.939 X

10:04:46 - . - - - - . - - - - - . - - - - 0.090 4.783 0.931 X

10:05:46 - . - - - - . - - - - - . - - - - 0.080 4.378 - . - - - X

10:06:26 - . - - - - . - - - - - . - - - - 0.080 4.295 0.933 X

10:07:10 - . - - - - . - - - - - . - - - - 0.080 4.327 0.927 X

10:07:46 - . - - - - . - - - - - . - - - - 0.080 4.266 - . - - - X

Limits: 1.000 0.650 0.500 7.000 3.300

Plt: 3.600905

Evaluated: dc, dmax average (4.550 %), d(t)

FLICKER: Test PASS!

Time Pmax Pst Sliding Plt d(t)>3.30% [s] dmax [%] dc [%] PASS FAIL

09:48:26 - . - - - - . - - - - - . - - - - 0.000 0.336 0.081 X

09:49:22 - . - - - - . - - - - - . - - - - 0.000 0.318 - . - - - X

09:50:22 - . - - - - . - - - - - . - - - - 0.000 0.319 - . - - - X

09:51:06 - . - - - - . - - - - - . - - - - 0.000 0.322 - . - - - X

09:51:46 - . - - - - . - - - - - . - - - - 0.000 0.340 - . - - - X

09:52:30 - . - - - - . - - - - - . - - - - 0.000 0.347 - . - - - X

09:53:26 - . - - - - . - - - - - . - - - - 0.000 0.353 - . - - - X

09:54:26 - . - - - - . - - - - - . - - - - 0.000 0.353 - . - - - X

09:55:06 - . - - - - . - - - - - . - - - - 0.000 0.353 - . - - - X

09:55:54 - . - - - - . - - - - - . - - - - 0.000 0.353 - . - - - X

09:56:46 - . - - - - . - - - - - . - - - - 0.000 0.353 - . - - - X

09:57:38 - . - - - - . - - - - - . - - - - 0.000 0.353 - . - - - X

09:58:26 - . - - - - . - - - - - . - - - - 0.000 0.353 - . - - - X

09:59:18 - . - - - - . - - - - - . - - - - 0.000 0.353 - . - - - X

10:00:10 - . - - - - . - - - - - . - - - - 0.000 0.358 - . - - - X

10:00:50 - . - - - - . - - - - - . - - - - 0.000 0.360 - . - - - X

10:01:34 - . - - - - . - - - - - . - - - - 0.000 0.360 - . - - - X

10:02:42 - . - - - - . - - - - - . - - - - 0.000 0.360 - . - - - X

10:03:42 - . - - - - . - - - - - . - - - - 0.000 0.360 - . - - - X

10:04:46 - . - - - - . - - - - - . - - - - 0.000 0.363 - . - - - X

10:05:46 - . - - - - . - - - - - . - - - - 0.000 0.363 - . - - - X

10:06:26 - . - - - - . - - - - - . - - - - 0.000 0.363 - . - - - X

10:07:10 - . - - - - . - - - - - . - - - - 0.000 0.369 - . - - - X

10:07:46 - . - - - - . - - - - - . - - - - 0.000 0.369 - . - - - X

Plt: 0.249695

Evaluated: PST <= 0.4 dmax < 20 % dmax1

FLICKER: Source test PASS!

Tested with SPS EMC 3.0.4 / None by Spitzenberger & Spies GmbH & Co. KG, Schmidstr. 32-34, 94234 Viechtach, Germany, 12.01.2012

Page 29: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 29 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

10.1. Immunity test: electrostatics discharge ESD

Scope To assess the performances of the appliances when they are

submitted to static electricity discharge, from operators directly, and to adjacent objects.

Reference standard EN 61000-4-2

EN 55014-2 Table 1

EUT operation mode # 1

EUT configuration mode # 1

Port Enclosure

Verdict

COMPLIANT

Test level apply (background grey)

Contact discharge Air discharge

Level Voltage level kV Level Voltage level kV

1 2 1 2

2 4 2 4

3 6 3 8

4 8 4 15

x special x special

Test equipment

Equipment Model Manufacturer Serial number

ESD generator ESD 30 EM TEST 0296-41

Set ESD generator

Method coupling Discharge electrodes 150pF + 330 ohm

Number of discharge > 10 for every point select

Repetition rate 1/second

Page 30: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 30 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

10.1. Immunity test: electrostatics discharge ESD

Test

Discharge points Type of discharge

Test voltage Result criterion

Remark

Enclosure, plastic parts Air ± 2kV A E.U.T. operated as intended

± 4kV A E.U.T. operated as intended

± 8kV A E.U.T. operated as intended

Enclosure VCP ± 2kV A E.U.T. operated as intended

± 4kV A E.U.T. operated as intended

± 6kV - -

Enclosure, metallic part

CONTACT ± 2kV A E.U.T. operated as intended

± 4kV A E.U.T. operated as intended

± 6kV - -

Display and keyboard Air ± 2kV A E.U.T. operated as intended

± 4kV A E.U.T. operated as intended

± 8kV A E.U.T. operated as intended

VCP= Vertical Coupling Plan HCP= Horizontal Coupling Plan

N.A.= Not Applicable

Page 31: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 31 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

10.2. Immunity test: radiated RF electromagnetic field

Scope To assess the performances of the appliances when they are

submitted to electromagnetic field.

Reference standard EN 61000-4-3 + A1 EN 55014-2 + A1 + A2 Table 11

EUT operation mode # 1

EUT configuration mode # 1

Port Enclosure

Verdict

NOT APPLICABLE

Test level (background grey)

Level Test field strength (V/m)

1 1

2 3

3 10

x x

Test equipment

Equipment Model Manufacturer Serial number

Semi Anechoic chamber 3mSAC Albatros Project

RF signal generator SML 03 Rohde & Schwarz 100162

Amplifier 100W1000M1 Amplifier Research 18650

Amplifier 150A400 Amplifier Research 0330804

Amplifier 30S1GS3 Amplifier Research 300786

Horn antenna 3115 Emco 9005-3475

Log-periodic antenna VULP 9118 E Schwarzbeck

Mess - Elektronik

9118E867

Set RF generator

Frequency range 80 – 1000 MHz

Modulation AM 80% 1 kHz sine-wave

Step 1%

Dwell time 3 second

Page 32: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 32 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

10.2. Immunity test: radiated RF electromagnetic field

Scope To assess the performances of the appliances when they are

submitted to electromagnetic field.

Reference standard EN 61000-4-3 + A1 EN 55014-2 + A1 + A2 Table 11

EUT operation mode # 1

EUT configuration mode # 1

Port Enclosure

Verdict

NOT APPLICABLE

Test level (background grey)

Level Test field strength (V/m)

1 1

2 3

3 10

x x

Test equipment

Equipment Model Manufacturer Serial number

Semi Anechoic chamber 3mSAC Albatros Project

RF signal generator SML 03 Rohde & Schwarz 100162

Amplifier 100W1000M1 Amplifier Research 18650

Amplifier 150A400 Amplifier Research 0330804

Amplifier 30S1GS3 Amplifier Research 300786

Horn antenna 3115 Emco 9005-3475

Log-periodic antenna VULP 9118 E Schwarzbeck

Mess - Elektronik

9118E867

Set RF generator

Frequency (MHz) 80, 230, 460, 690, 1000

Modulation AM 80% 1 kHz sine-wave

Step -

Dwell time 180 seconds for every frequency

Page 33: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 33 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

10.3. Immunity test: electrical fast transients, burst

Scope To assess the performances of the appliances when they are

submitted to repetitive electrical fast transients.

Reference standard EN 61000-4-4 + A1 EN 55014-2 + A1 + A2 Table 4

EUT operation mode # 1

EUT configuration mode # 1

Port A.C. power supply

Verdict

COMPLIANT

Test level (background grey)

Level On power supply port , ground On I/O signal, data and control

ports

Voltage peak kV Repetition rate kHz Voltage peak kV Repetition rate kHz

1 0,5 5 0,25 5 2 1 5 0,5 5 3 2 5 1 5 4 4 5 2 5 x

Test equipment

Equipment Model Manufacturer Serial number

Burst generator EFT 500M4 EM TEST V0712102348

Clamp 1 meter EM TEST

Set burst generator

Method coupling for power supply Direct with capacitor 33nF

Method coupling for signal I/O Capacitive clamp long 1 meter

Test duration ≥ 120 second

Test

Coupling port Test voltage Result criterion Remark

A.C. power supply

± 1kV A E.U.T. operated as

intended

Page 34: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 34 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

10.4. Immunity test: surge

Scope To assess the performances of the appliances when they are

submitted to over voltage from switching and lightning transients.

Reference standard EN 61000-4-5 EN 55014-2 + A1 + A2 Table 12

EUT operation mode # 1

EUT configuration mode # 1

Port A.C. power supply

Verdict

COMPLIANT

Test level (background grey)

Installation

class

AC power supply and a.c.

I/O directly connected to

the mains network.

Coupling mode

AC power supply and a.c.

I/O don’t directly

connected to the mains network.

Coupling mode

DC power supply and d.c. I/O

directly connected

thereto

Coupling mode

Unsymmetrical operated

circuit/lines

Coupling mode

Symmetrical operated

circuit/lines

Coupling mode

Unsymmetrical operated circuit/lines

Coupling mode

Line to

line

Line to

ground

Line to

line

Line to

ground

Line to

line

Line to

ground

Line to

line

Line to

ground

Line to

line

All line to

ground

Line to

line

Line to

ground

0 NA NA NA NA NA NA NA NA NA NA NA NA

1 NA 0,5 NA NA NA NA NA 0,5 NA 0,5 NA NA

2 0,5 1 NA NA NA 0,5 0,5 1 NA 1 NA 0,5

3 1 2 1 2 1 1 1 2 NA 2 NA 2

4 2 4 2 4 2 2 2 4 NA 4 NA 4

5 X X 2 4 2 2 2 4 NA 4 NA 4

Test equipment

Equipment Model Manufacturer Serial number

Surge generator VCS 500 EM TEST 0995-03

Set surge generator

Method coupling Source impedance 2 ohm

Line – line = capacitor 18uF

Line – earth = capacitor 9uF + impedance 10 ohm

Method coupling for shielded cable I/O Source impedance 2 ohm, cable long 20 meter, with

shielded connect to earth

Coupling phase 90° - 270°

Number of surge 5 for each parameter combination

Repetition rate Max 1/minute

Page 35: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 35 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

10.4. Immunity test: surge

Test

Coupling port Coupling mode and phase

Test voltage Result criterion

Remark

A.C. power

supply

Differential

(line – line) 90° - 270°

± 500V A E.U.T. operated as intended

± 1kV A E.U.T. operated as intended

A.C. power supply

Common (line – earth)

90° - 270°

± 1kV A E.U.T. operated as intended

± 2kV A E.U.T. operated as intended

Page 36: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 36 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

10.5. Immunity test: conducted disturbance, induced RF field

Scope To assess the performances of the appliances when they are

submitted to induced RF field.

Reference standard EN 61000-4-6 EN 55014-2 + A1 + A2 Table 7

EUT operation mode # 1

EUT configuration mode # 1

Port A.C. power supply

Verdict

COMPLIANT

Test level (background grey)

Level Voltage level (e. m. f.)

(unmodulated, rms)

1 1

2 3

3 10

x x

Test equipment

Equipment Model Manufacturer Serial number

RF signal generator SML 03 Rohde & Schwarz 100162

Amplifier 150A400 Amplifier Research 0330804

CDN M3 MEB 12859

Set RF generator

Frequency range 0.15 - 230 MHz

Modulation AM 80% 1 kHz sine-wave

Step 1%

Dwell time 3 second

Test

Coupling port Coupling method Result criterion Remark

A.C. power supply

CDN M3 A E.U.T. operated as

intended

Page 37: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 37 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

10.5. Immunity test: conducted disturbance, induced RF field

Scope To assess the performances of the appliances when they are

submitted to induced RF field.

Reference standard EN 61000-4-6 EN 55014-2 + A1 + A2 Table 7

EUT operation mode # 1

EUT configuration mode # 1

Port A.C. power supply

Verdict

COMPLIANT

Test level (background grey)

Level Voltage level (e. m. f.)

(unmodulated, rms)

1 1

2 3

3 10

x x

Test equipment

Equipment Model Manufacturer Serial number

RF signal generator SML 03 Rohde & Schwarz 100162

Amplifier 150A400 Amplifier Research 0330804

CDN M3 MEB 12859

Set RF generator

Frequency (MHz) 0.15 , 20, 40, 60, 80

Modulation AM 80% 1 kHz sine-wave

Step -

Dwell time 180 seconds for every frequency

Test

Coupling port Coupling method Frequency (MHz) Result criterion Remark

A.C. power supply

CDN M3 0.15 A E.U.T. operated as

intended

A.C. power supply

CDN M3 20 A E.U.T. operated as

intended

A.C. power supply

CDN M3 40 A E.U.T. operated as intended

A.C. power supply

CDN M3 60 A E.U.T. operated as

intended

A.C. power supply

CDN M3 80 A E.U.T. operated as

intended

Page 38: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 38 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

10.6. Immunity test: voltage dips and short interruptions

Scope To assess the performances of the appliances when they are

subjected to voltage dips, short interruptions and voltage variations.

Reference standard EN 61000-4-11 EN 55014-2 + A1 + A2 Table 13

EUT operation mode # 1

EUT configuration mode # 1

Port A.C. power supply

Verdict

COMPLIANT

Test level

Test Test level in % of Ut Duration

(in periods of rated frequency)

Interruption N° 1 0 0,5

Voltage dips N° 2 40 10

Voltage dips N° 3 70 25

Ut = power supply of E.U.T. (230V a.c.)

Test equipment

Equipment Model Manufacturer Serial number

Dips simulator PFS 500 EM TEST 0296-04

Test

Voltage test level % of Ut

Reduction time (ms)

Dip starting phase

Result criterion

Remark

-100% 10

0° A E.U.T. operated as intended

-60% 200

0° B Change speed motor, after the test E.U.T. operated as intended

-30% 500

0° B Change speed motor, after the

test E.U.T. operated as intended

Page 39: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 39 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

11. Photo

Photo 1 Emission measurement: disturbance power Photo 2 Emission measurement: continuous disturbance

Photo 3 Emission measurement: harmonics and flicker Photo 4 Immunity test: conducted disturbance, induced

RF field

Photo 5 Immunity test: voltage dips and short

interruptions Photo 6 Immunity test: electrical fast transients, burst

Page 40: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 40 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

11. Photo

Photo 7 Immunity test: surge Photo 8 Immunity test: electrostatics discharger ESD

Photo 9 Immunity test: electrostatics discharger ESD

Page 41: R-21 EMC 2012€¦ · 9.2. Emission measurement: discontinuous disturbance 16 - 17 9.3. Emission measurement: disturbance power 18 - 24 9.4. Emission measurement: electromagnetic

Constructor Product Report reference Date of test report Page

A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 41 of 41

ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it

12. Modify

Modify introduced to EMC test compliance

Port Test fail Modify

A.C. power supply Emission conducted Change EMI Filter with model:

High & Low Corporation

EMI Filter - IEC Inlet Filters SS1 series Standard case

Voltage 250V Current rating 6A

Capacitor Cx 0,1µF Inductor L 2x0,8mH

Capacitor Cy 2x200pF