radiant barrier foil

50

Click here to load reader

Upload: sachindesai055

Post on 19-May-2015

659 views

Category:

Business


0 download

TRANSCRIPT

Page 1: Radiant barrier foil

By

Shrikant Athavale

Prathith Consultants

Pune India

1 28-01-2014

Pro

mis

e to

at

ten

d y

ou

r T

ech

. n

eed

s

Page 2: Radiant barrier foil

2 28-01-2014

are you worried of

Heat losses ? ( in coming

or

out going )

Pro

mis

e to

at

tend

y

ou

r T

ech

. n

eed

s

Page 3: Radiant barrier foil

3 28-01-2014

Pro

mis

e to

at

ten

d y

ou

r T

ech

. n

eed

s

Roofing/Walls/Pipe

lines

Insulation

Insulation

Heat loss

Almost 30-

35%

Without

Insulation

To Save

Energy

cost

To Maintain

required room

temp

To reduce

carbon foot

Print

Thermal

Insulation

Why

?

Page 4: Radiant barrier foil

4 28-01-2014

Pro

mis

e to

at

tend

y

ou

r T

ech

. n

eed

s Radiant barriers

are manufacturing using Aluminium Foil / Alu foil laminated

Fibre Glass , etc, Reinforcing Scrim and paper/film od other

Substrates. a suitable lamination adhesive is used for

bonding these substrates.

By using a radiant barrier on the Roof or below the ceiling ,

reflects the solar energy and stops the Heat absorption .

This help in keeping the premises cooler and reduces the

electrical consumption of Air conditioners.

The radiant barrier , this way blocks almost 85-90% , of the

Heat Radiation.

This applicable , in summer as well in Winter.

Page 5: Radiant barrier foil

5 28-01-2014

Pro

mis

e to

at

ten

d y

ou

r T

ech

. n

eed

s How to choose

the Right material for your Insulation

needs ?

One has to look into

Cost

Ease of Installation

Emissivity

Reinforcement

Affordable Width

Fire Rating

Page 6: Radiant barrier foil

6 28-01-2014

We now represent a Giant Chinese

Manufacturer .

Markets that we serve

India,

Middle east ,

Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Page 7: Radiant barrier foil

7 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Products at a Glance

Page 8: Radiant barrier foil

8 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Page 9: Radiant barrier foil

9 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Page 10: Radiant barrier foil

10 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Page 11: Radiant barrier foil

11 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds The Manufacturing

Equipment

Page 12: Radiant barrier foil

12 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

The Manufacturing

Equipment

Page 13: Radiant barrier foil

13 28-01-2014

Application area’s

Roof ,

Floor,

,

Water heaters ,

Water pipes,

Protective outer layer

Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Page 14: Radiant barrier foil

14 28-01-2014

More about Application

In construction

such as Subway ,Tunnel, Airport, malls

and

for fire proof,

combustion prevention,

sound absorption,

vibration damping,

heat preservation,

waterproof,

anticorrosive, Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Page 15: Radiant barrier foil

15 28-01-2014

Punched

Foil-Scrim-Kraft

Facing

Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

FSK 1004 K – 1

Structure : Aluminium Foil

/ PE / 3 way Scrim / Kraft

Gsm : 85

Water Vapor Penetration :

2.0 nm/ NS

Temp resistance : 4 hrs/ 90

deg C

Page 16: Radiant barrier foil

16 28-01-2014

Specialty laminate of Alu. foil and Polyethylene (

Heat Resistant & Thermally Insulating ) to stop

penetration of UV light through walls, wood,

The are

heat insulation, anti radiation, energy saving

Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Page 17: Radiant barrier foil

17 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Page 18: Radiant barrier foil

18 28-01-2014

Double Sandwitch

Alu. Foil

Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Page 19: Radiant barrier foil

19 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Page 20: Radiant barrier foil

20 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Page 21: Radiant barrier foil

21 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Page 22: Radiant barrier foil

22 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Page 23: Radiant barrier foil

23 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Page 24: Radiant barrier foil

24 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Page 25: Radiant barrier foil

25 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Page 26: Radiant barrier foil

26 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

FSK 1004 – 3

Structure : Aluminum Foil /

PE / EPE Foam

Gsm : 167

Water Vapor Penetration :

2.0 nm/ NS

Temp resistance :

4 hrs/ 90 deg C

Page 27: Radiant barrier foil

27 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

FSK 1004 – 4 Structure : Aluminium

Foil / PE / Kraft paper

Gsm : 93

Water Vapor Penetration

: 2.0 nm/ NS

Temp resistance : 4 hrs/

90 deg C

Page 28: Radiant barrier foil

28 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

FSK 1004 K – 1 Structure : Aluminium Foil / PE

/ 3 way Scrim / Kraft

Gsm : 85

Water Vapor Penetration : 2.0

nm/ NS

Temp resistance : 4 hrs/ 90 deg

C

Page 29: Radiant barrier foil

29 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

FSK 1004 S – 11 Structure : Aluminium Foil / PE / 2

way Scrim / PE/Alu foil

Gsm : 85

Water Vapor Penetration : 2.0 nm/ NS

Temp resistance : 4 hrs/ 90 deg C

Page 30: Radiant barrier foil

30 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

FSK 1004 H – 11 Structure : Aluminium Foil / PE

/ 3 way Scrim / Kraft/Pe/ Alu Foil

Gsm : 127

Water Vapor Penetration : 1.15

nm/ NS

Temp resistance : 4 hrs/ 90 deg

C

Page 31: Radiant barrier foil

31 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

FSK 1009 A – 16

Structure : Non Woven / PE

Gsm : 100

Water Vapor Penetration :

2.00 nm/ NS

Temp resistance :

4 hrs/ 90 deg C

Page 32: Radiant barrier foil

32 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

FSK 1009 A – 17

Structure : Alu Foil / PE /Non

Woven

Gsm : 90

Water Vapor Penetration :

2.00 nm/ NS

Temp resistance :

4 hrs/ 90 deg C

Page 33: Radiant barrier foil

33 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

WPSK 1009 A – 13

Structure : Black PP/FR

Adhesive/3 way Scrim / Kraft

paper

Gsm : 150

Temp resistance :

4 hrs/ 100 deg C

Page 34: Radiant barrier foil

34 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

WPSK 1009 A – 14

Structure : Black PP/FR

Adhesive/3 way Scrim / Alu

Foil/Kraft paper

Gsm : 182

Temp resistance :

4 hrs/ 100 deg C

Page 35: Radiant barrier foil

35 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

WPSK 1009 B

Structure : White PE/

Adhesive/ 3 way scrim / Kraft/

PE

Gsm : 105

Temp resistance :

4 hrs/ 90 deg C

Page 36: Radiant barrier foil

36 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

WPSK 1009 K

Structure : White PE/ Adhesive/ 3

way scrim / Kraft

Gsm : 86

Temp resistance :

4 hrs/ 90 deg C

Page 37: Radiant barrier foil

37 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

WPSK 1007 A - 3 Structure : Aluminium

Foil / FR adhesive / Fibre

Glass cloth

Gsm : 105

Temp resistance :

4 hrs/ 100 deg C

Page 38: Radiant barrier foil

38 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

WPSK 1007 A - 2 Structure : Aluminium Foil / PE/

3x 3 mesh

Gsm : 292

Temp resistance :

4 hrs/ 100 deg C

Page 39: Radiant barrier foil

39 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

FSK 1007 K

Structure : Aluminium Foil / PE

/ 3X3 mesh

Gsm : 127

Temp resistance :

4 hrs/ 90 deg C

Page 40: Radiant barrier foil

40 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

WPSK 1007 12

Structure : Aluminium Foil / PE /

Bubble

Gsm : 250

Temp resistance :

4 hrs/ 90 deg C

Page 41: Radiant barrier foil

41 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds Residential

R+HEATSHIELD installed over

roof rafters reduces summer heat

gain in the attic, resulting in lower

energy costs for this residence

Industrial

ASTRO-FOIL installed in this

fabricating facility brightens the

interior and reduces heat loss.

Industrial

ASTRO-FOIL installed in this

fabricating facility brightens the

interior and reduces heat loss.

Page 42: Radiant barrier foil

42 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Recreational Vehicles

These RV's have ULTRA-

DUCT insulated air-

conditioning ducts. The ULTRA-

DUCTS increase

the airflow and provide cooler air for

the entire unit.

ASTRO-FOIL products are ideal for

this commercial structure. The

lightweight, versatile insulation will

reduce energy consumption and cut

building costs.

Agricultural

ASTRO-WHITE was installed over

the purlins in this horse barn, to

increase animal comfort during the

hot summer months.

Page 43: Radiant barrier foil

43 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Duct Wrap Insulation

Product Description

Basic Use:

SoftTouch Duct Wrap Insulation is used to

insulate rectangular and round heating,

ventilating and air conditioning ductwork.

Benefits:

SoftTouch Duct Wrap Insulation provides

thermal efficiency that reduces unwanted heat

loss or gain from equipment and ductwork.

When properly installed in the correct thickness,

this product virtually eliminates condensation

problems on cold duct surfaces.

Page 44: Radiant barrier foil

44 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

R+HEATSHIELD is Innovative

Energy's line of radiant barrier

insulation products made from a woven

polyethylene material covered by a

metalized film. This metalized film

provides a reflective surface that blocks

94 percent of radiant heat, so it helps

keep spaces cooler in summer and

warmer in winter. R+HEATSHIELD

can dramatically improve thermal

performance and energy efficiency,

keeping energy costs lower and interior

spaces more comfortable.

Why Use Radiant Barrier?

Cuts energy consumption and costs

Improves interior comfort

An economical radiant barrier

insulation in attic spaces

Effective means of temperature

control in a wide variety of

applications

Solid version qualifies as an air and

moisture barrier

Superior tear and puncture resistance

Can span eight feet unsupported

Environmentally safe and non-toxic

Lightweight; easy and safe to install

Page 45: Radiant barrier foil

45 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds Astro Shield, an improved version of the

product previously known as Astro Foil, is a

line of reflective insulation products featuring

polyethylene bubble film sandwiched

between two protective sheets of strong

metalized aluminum polyester film. This

metalized aluminum film provides a

reflective surface that blocks 94 percent of

radiant heat, unlike fiberglass, foam or

cellulose insulation, which absorb heat. When

materials absorb heat, they merely slow down

its transfer. Astro Shield can dramatically

improve thermal performance and energy

efficiency, keeping energy costs lower and

interior spaces more comfortable.

Page 46: Radiant barrier foil

46 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

1. in your attic to prevent heat build-up during summer months and reduce heat loss during winter.

2. in your sidewalls will improve the performance of mass insulation by reducing radiant heat transfer,

creating a more efficient building envelope.

3. to insulate below your radiant heated floors to reduce hot spots, prevent heat loss and increase the

efficiency of your radiant heating unit.

4. Keep your garage temperature more comfortable year-round

5. Seal your ducts by wrapping them. You will minimize energy use by keeping the air flowing through the

registers, not escaping into unwanted areas.

6. Line crawl spaces will help floors stay warm and dry, lowering your energy bills.Water heaters are one of

the most energy-consuming appliances in your home. Our easy-to-install

7. Water Heater Insulation Jacket will improve water heater thermal performance and reduce your energy

needs.

Page 47: Radiant barrier foil

47 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

For equipment that requires control of heat build-up

and proper flow of air in small spaces, Innovative

Energy's

AstroShield, astroECO andR+HEATSHIELD

HD products fit the bill. These reflective insulation

products effectively block heat intrusion and facilitate

outstanding airflow in small spaces, and can be

customized to suit virtually any application. Innovative

Energy products help achieve cost savings and

increased energy efficiency for a wide variety of

equipment - HVAC units, medical machinery and

currency counting machinery, just to name a few. Find

out how Innovative Energy can help keep your

equipment up and running.

Page 48: Radiant barrier foil

48 28-01-2014 Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Get in touch

for Product Information,

Pricing,

and

Sample requests

Page 49: Radiant barrier foil

49 28-01-2014

For more Information : www.psadhesive.com

Contact Details

Email : [email protected]

Personal Email : [email protected]

Cell : 00 91 7588288204

Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds

Page 50: Radiant barrier foil

50 28-01-2014

Tell me more

The heart of a meaningful conversation

Designed to share knowledge and

Understanding for mutual benefit

Pro

mis

e to

at

tend

yo

ur

Tec

h.

nee

ds