radiation monitoring systems - d&d km-it...neutrons outside the reactor core for neutron dose...

2
Featuring: radiation monitoring systems A Mirion Technologies Division BF3 COUNTER TUBES Neutron Flux Instrumentation BF3 COUNTER TUBES Proportional Counter Tubes BF3 Filled The neutron sensitivity of these proportional counters is achieved by filling the tube with the gas boron-tri- fluorid, made of highly enriched Boron-10. Thermal neutrons react with the isotope Boron-10 emitting alpha particles, which produce ionization in the gas filling of the detector (electrons and gas ions). In the electrical field between the electrodes these charged particles will be accelerated and secondary ionization happens. This so called “gas amplification” multiplies proportionally the amount of charge generated in the tube. APPLICATIONS • Operational process monitoring Detection and measurement of the thermal neutrons outside the reactor core for neutron dose rate monitoring and neutron flux monitoring in the pulse range RELATED PRODUCTS • KNK/KNU 50: neutron ionization chambers • Self-powered neutron detectors • TK 250: digital signal processing channels for start-up and power range FEATURES Detection of thermal neutrons High sensitivity due to filling with enriched BF 3 gas Proven construction 1” (25.4 mm) diameter Large measuring range Output signal: charge pulses Very low gamma sensitivity

Upload: others

Post on 31-May-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Featuring:

radiation monitoring systemsA Mirion Technologies Division

BF3 COUNTER TUBES

Neutron Flux Instrumentation

BF3 COUNTER TUBESProportional Counter Tubes BF3 Filled

The neutron sensitivity of these proportional counters

is achieved by ! lling the tube with the gas boron-tri-

" uorid, made of highly enriched Boron-10. Thermal

neutrons react with the isotope Boron-10 emitting

alpha particles, which produce ionization in the gas

! lling of the detector (electrons and gas ions). In the

electrical ! eld between the electrodes these charged

particles will be accelerated and secondary ionization

happens. This so called “gas ampli! cation” multiplies

proportionally the amount of charge generated in the

tube.

APPLICATIONS

• Operational process monitoring

○ Detection and measurement of the thermal

neutrons outside the reactor core for neutron dose

rate monitoring and neutron " ux monitoring in the

pulse range

RELATED PRODUCTS

• KNK/KNU 50: neutron ionization chambers

• Self-powered neutron detectors

• TK 250: digital signal processing channels for

start-up and power range

FEATURES

● Detection of thermal neutrons

● High sensitivity due to ! lling with enriched BF3 gas

● Proven construction

● 1” (25.4 mm) diameter

● Large measuring range

● Output signal: charge pulses

● Very low gamma sensitivity

Since norms, speci� cations and designs are subject to occasional change, please ask for con� rmation of the information given in this publication.

Mirion Technologies (MGPI) SA

Route d’Eyguières

FR-13113 Lamanon

France

T +33 (0) 4 90 59 59 59

F +33 (0) 4 90 59 55 18

Mirion Technologies (MGPI) Inc

5000 Highlands Parkway

Suite 150

Smyrna, GA 30082

USA

T +1 770 432 2744

F +1 770 432 9179

Mirion Technologies (MGPI H&B) GmbH

Landsberger Strasse 328a

DE-80687 Munich

Germany

T +49 (0) 89515 13-0

F +49 (0) 89515 13 169

Mirion Commercial (Beijing) Co., Ltd.

Shanghai Jiangchang Commercial Branch

Room 801, 78 Jiangchang SanLu

Zhabei District, Shanghai 200436

PR of China

T +86 21 6180 6920

F +86 21 6180 6924

BF3 COUNTER TUBES

Neutron Flux Instrumentation

www.mirion.com

145018EN-B

348 243 EN-C

PREFERRED TYPES OF THE 1” SERIES

Notice: 1 nv = 1/cm2s; 1 cps/nv = 1 cm2

COMMON DATA

● Max. operating temperature: 120°C (248°F),

WL-24425/-24427: 107°C (224°F)

● Gas # lling: BF3-gas with > 90% enriched B10

● Housing: aluminium

● Insulators: alumina ceramic

● Manufacturer: Mirion Technologies (IST) Corporation,

Horseheads, NY/USA

Type Sensitivity Measuring Range Operating Voltage Gas Pressure Length Connector

WL-23274 4.5 cps/nv 0.1 … 1e5 nv 2000V 55 cm Hg 305 mm (12 in) HN

WL-23069 6.5 cps/nv 0.08 … 7e4 nv 2000V 55 cm Hg 392 mm (15.4 in) HN

WL-24427

(~WL-23817)

10 cps/nv 0.1 … 1e4 nv 1825V 55 cm Hg 594 mm (23.4 in) #237*

WL-23058 13 cps/nv 0.04 … 4e4 nv 4000V 160 cm Hg 305 mm (12 in) HN

WL-23057 19 cps/nv 0.03 … 2.6e4 nv 2200V 160 cm Hg 392 mm (15.4 in) HN

WL-24425

(~WL-23770)

25 cps/nv 0.04 … 4e3 nv 3000V 160 cm Hg 594 mm (23.4 in) #237*

*Designed for the pulse range of the KWU-PWR with PET coaxial plug type 237