![Page 1: RAPID P B S P R (SPR) D USING COMSOL & M S · "RAPID PROTOTYPING" OF BIOSENSING SURFACE PLASMON RESONANCE (SPR) DEVICES. USING. COMSOL & M. ATLAB. S. OFTWARE. Presented by. Dominic](https://reader036.vdocuments.net/reader036/viewer/2022081514/5ec558c913b08355f20aa317/html5/thumbnails/1.jpg)
"RAPID PROTOTYPING" OF BIOSENSING SURFACE
PLASMON RESONANCE (SPR) DEVICES
USING COMSOL & MATLAB SOFTWARE
Presented byDominic Carrier
Presented at the COMSOL Conference 2009 Boston
![Page 2: RAPID P B S P R (SPR) D USING COMSOL & M S · "RAPID PROTOTYPING" OF BIOSENSING SURFACE PLASMON RESONANCE (SPR) DEVICES. USING. COMSOL & M. ATLAB. S. OFTWARE. Presented by. Dominic](https://reader036.vdocuments.net/reader036/viewer/2022081514/5ec558c913b08355f20aa317/html5/thumbnails/2.jpg)
• Introductiono Why do we need biosensing?o What is biosensing?o How we do it (with SPR)?
• Setup
• Results
2
![Page 3: RAPID P B S P R (SPR) D USING COMSOL & M S · "RAPID PROTOTYPING" OF BIOSENSING SURFACE PLASMON RESONANCE (SPR) DEVICES. USING. COMSOL & M. ATLAB. S. OFTWARE. Presented by. Dominic](https://reader036.vdocuments.net/reader036/viewer/2022081514/5ec558c913b08355f20aa317/html5/thumbnails/3.jpg)
3
INTRO - WHY
![Page 4: RAPID P B S P R (SPR) D USING COMSOL & M S · "RAPID PROTOTYPING" OF BIOSENSING SURFACE PLASMON RESONANCE (SPR) DEVICES. USING. COMSOL & M. ATLAB. S. OFTWARE. Presented by. Dominic](https://reader036.vdocuments.net/reader036/viewer/2022081514/5ec558c913b08355f20aa317/html5/thumbnails/4.jpg)
4
Distance
Inte
nsity
INTRO - WHAT
![Page 5: RAPID P B S P R (SPR) D USING COMSOL & M S · "RAPID PROTOTYPING" OF BIOSENSING SURFACE PLASMON RESONANCE (SPR) DEVICES. USING. COMSOL & M. ATLAB. S. OFTWARE. Presented by. Dominic](https://reader036.vdocuments.net/reader036/viewer/2022081514/5ec558c913b08355f20aa317/html5/thumbnails/5.jpg)
Negative real dielectric constant allows propagating evanescent surface wave (a.k.a. Surface plasmons)
5
INTRO - HOW
Dielectric
Metallic Layer
![Page 6: RAPID P B S P R (SPR) D USING COMSOL & M S · "RAPID PROTOTYPING" OF BIOSENSING SURFACE PLASMON RESONANCE (SPR) DEVICES. USING. COMSOL & M. ATLAB. S. OFTWARE. Presented by. Dominic](https://reader036.vdocuments.net/reader036/viewer/2022081514/5ec558c913b08355f20aa317/html5/thumbnails/6.jpg)
6
INTRO - HOW
![Page 7: RAPID P B S P R (SPR) D USING COMSOL & M S · "RAPID PROTOTYPING" OF BIOSENSING SURFACE PLASMON RESONANCE (SPR) DEVICES. USING. COMSOL & M. ATLAB. S. OFTWARE. Presented by. Dominic](https://reader036.vdocuments.net/reader036/viewer/2022081514/5ec558c913b08355f20aa317/html5/thumbnails/7.jpg)
7
WHY
![Page 8: RAPID P B S P R (SPR) D USING COMSOL & M S · "RAPID PROTOTYPING" OF BIOSENSING SURFACE PLASMON RESONANCE (SPR) DEVICES. USING. COMSOL & M. ATLAB. S. OFTWARE. Presented by. Dominic](https://reader036.vdocuments.net/reader036/viewer/2022081514/5ec558c913b08355f20aa317/html5/thumbnails/8.jpg)
8
A B
Incident Light
INTRO - SP 101
![Page 9: RAPID P B S P R (SPR) D USING COMSOL & M S · "RAPID PROTOTYPING" OF BIOSENSING SURFACE PLASMON RESONANCE (SPR) DEVICES. USING. COMSOL & M. ATLAB. S. OFTWARE. Presented by. Dominic](https://reader036.vdocuments.net/reader036/viewer/2022081514/5ec558c913b08355f20aa317/html5/thumbnails/9.jpg)
9
A B A+B
Symmetry Axis
PMLLight Source
Sensing AreaIncident Light Modulated
Surface Plasmon
SETUP
![Page 10: RAPID P B S P R (SPR) D USING COMSOL & M S · "RAPID PROTOTYPING" OF BIOSENSING SURFACE PLASMON RESONANCE (SPR) DEVICES. USING. COMSOL & M. ATLAB. S. OFTWARE. Presented by. Dominic](https://reader036.vdocuments.net/reader036/viewer/2022081514/5ec558c913b08355f20aa317/html5/thumbnails/10.jpg)
10
Symmetry Axis
PMLLight Source
SETUP
Model Specs:• RF Module : 2D in-plane “Harmonic propagation”• Typically 20 to 50 um long• 10 to 20 node elements per wavelength (total ~250 000 elements)
![Page 11: RAPID P B S P R (SPR) D USING COMSOL & M S · "RAPID PROTOTYPING" OF BIOSENSING SURFACE PLASMON RESONANCE (SPR) DEVICES. USING. COMSOL & M. ATLAB. S. OFTWARE. Presented by. Dominic](https://reader036.vdocuments.net/reader036/viewer/2022081514/5ec558c913b08355f20aa317/html5/thumbnails/11.jpg)
11
RESULTS - PART 1
![Page 12: RAPID P B S P R (SPR) D USING COMSOL & M S · "RAPID PROTOTYPING" OF BIOSENSING SURFACE PLASMON RESONANCE (SPR) DEVICES. USING. COMSOL & M. ATLAB. S. OFTWARE. Presented by. Dominic](https://reader036.vdocuments.net/reader036/viewer/2022081514/5ec558c913b08355f20aa317/html5/thumbnails/12.jpg)
12
|Hz|
At Anti-ResonanceAt Resonance
RESULTS - PART 2
![Page 13: RAPID P B S P R (SPR) D USING COMSOL & M S · "RAPID PROTOTYPING" OF BIOSENSING SURFACE PLASMON RESONANCE (SPR) DEVICES. USING. COMSOL & M. ATLAB. S. OFTWARE. Presented by. Dominic](https://reader036.vdocuments.net/reader036/viewer/2022081514/5ec558c913b08355f20aa317/html5/thumbnails/13.jpg)
13
RESULTS - PART 3
![Page 14: RAPID P B S P R (SPR) D USING COMSOL & M S · "RAPID PROTOTYPING" OF BIOSENSING SURFACE PLASMON RESONANCE (SPR) DEVICES. USING. COMSOL & M. ATLAB. S. OFTWARE. Presented by. Dominic](https://reader036.vdocuments.net/reader036/viewer/2022081514/5ec558c913b08355f20aa317/html5/thumbnails/14.jpg)
14
• Successfully achieved reproduction of SPR with Comsol
• Using “rapid-prototyping”, creation of diverse geometry was easy
• Modulation of output signal is observed
• The SP grating cavity is a promising scheme for Biosensing
![Page 15: RAPID P B S P R (SPR) D USING COMSOL & M S · "RAPID PROTOTYPING" OF BIOSENSING SURFACE PLASMON RESONANCE (SPR) DEVICES. USING. COMSOL & M. ATLAB. S. OFTWARE. Presented by. Dominic](https://reader036.vdocuments.net/reader036/viewer/2022081514/5ec558c913b08355f20aa317/html5/thumbnails/15.jpg)
15
Prof. Jan J. Dubowski
![Page 16: RAPID P B S P R (SPR) D USING COMSOL & M S · "RAPID PROTOTYPING" OF BIOSENSING SURFACE PLASMON RESONANCE (SPR) DEVICES. USING. COMSOL & M. ATLAB. S. OFTWARE. Presented by. Dominic](https://reader036.vdocuments.net/reader036/viewer/2022081514/5ec558c913b08355f20aa317/html5/thumbnails/16.jpg)
16
Thank you