raptor - petroleum club · raptor a new high-technology, high-value pulsed neutron measurement from...

27
Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from Weatherford Pulsed Neutron Measurement from Weatherford Dr. Darryl Trcka Senior Research Scientist © 2012 Weatherford. All rights reserved. © 2012 Weatherford. All rights reserved. Raptor Interpretive Product Manager

Upload: dotram

Post on 02-Apr-2018

224 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

RaptorA New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford

Dr. Darryl TrckaSenior Research Scientist

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved.

Raptor Interpretive Product Manager

Page 2: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

1964Lane Wells

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 2

Page 3: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

1969“Slim tool”

“Through tubing”Through tubing

SchlumbergerBaker Hughes

Halliburton

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 3

Page 4: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

2003Baker Hughes

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 4

Page 5: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

2010Weatherford

Raptor

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 5Casedhole Reservoir Evaluation Tool (CRE)

Page 6: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

2010Weatherford

Raptor

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 6

Page 7: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

Why four detectors?For Gas Saturation Measurements (We already know that.)

Water-Oil Response Line

Gas Response Line

Raptor 5-Detector Tool

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 7

Page 8: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

Why four detectors?

Wet Response Line

Raptor 4-Detector ToolStandard 3-Detector Tool

Gas Response

Standard 3-Detector ToolRaptor 5-Detector Tool

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 8

Standard 2-Detector Tool

Page 9: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

Raptor-COWhy use four detectors?

• We have four detectors instead of two. Which do you use for the CO measurement?

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 9

Page 10: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

Raptor-Sigma Why use four detectors?

• We have four detectors instead of two. Which do you use for the sigma measurement?g

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 10

Page 11: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

Hardware Summary

• Larger Detector Array

Senses more formation volume – Most sensitive tool in the industry

• New Detector Type

Fastest detector in the industry – High count rates, faster loggingy g , gg g

Brightest detector in the industry – Less noise, more signal

• Sensitivity Calibration System

Multi-point calibrator – More accuracy, more confidence

• EfficiencyEfficiency

Combinability – PN+Bond+PL

Memory Operation – Field Test in 2013

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 11

Page 12: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

The Road to High-Value Petrophysical Solutions

High-Value Answer Products

Distributed Analysis

Production Petrophysics

Characterization

Algorithms

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 12Instrumentation

Page 13: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

New Algorithm Development

• Raptor-CO

New formation-view technique – Proof that the tool is seeing the formation

New shale and mineralogy handling – Lime, dolomite, sand, shale

• Raptor N-Vision Measurement (Gas Saturation Measurement)

Measurement method not based on CO or Sigma

Saturations are determined by measuring pore fluid density:

Basis for the Raptor-Gas product for gas saturation p p g

• Raptor-Sigma

Diffusion corrected sigma (available 2012) – High accuracy sigma

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 13

Page 14: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

The Road to High-Value Petrophysical Solutions

Di t ib t d A l i

High-Value Answer Products

Distributed Analysis

Production Petrophysics

Characterization

Algorithms

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 14Instrumentation

Page 15: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

Characterization Problems in Artificial Pits

• Most conditions are impossible to characterize in artificial formation pits:

– Gas formations– Gas behind tubing– Foam cement– Formation gas and oil of variable density– Tubing and packers– EOR processes (floods, WAG, SAGD, CO2, N2)– Condensate– Washouts

D illi fl id– Drilling fluids– Screens– Gravel packs– Blast joints

Horizontal wellbores– Horizontal wellbores– High-angle wellbores– Invasion effects– Partial saturation values– Partial or mixed borehole holdup values

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 15

Partial or mixed borehole holdup values– Coning/cresting

Page 16: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

Raptor Characterization with Monte Carlo Modeling

• Single-well, high-fidelity response characterization

– Each well is characterized for:

• Hole size

• Casing size, weight

• Sand, Lime, Dolomite

• Borehole fluid density/salinity

• Formation oil density

• Tubing strings

• Tubing/annulus fluids

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 16

Page 17: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

The Road to High-Value Petrophysical Solutions

High-Value Answer Products

Distributed Analysis

Production Petrophysics

Characterization

Algorithms

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 17Instrumentation

Page 18: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

The Road to High-Value Petrophysical Solutions

High-Value Answer Products

Distributed Analysis

Production Petrophysics

Characterization

Algorithms

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 18Instrumentation

Page 19: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

The Road to High-Value Petrophysical Solutions

High-Value Answer Products

Distributed Analysis

Production Petrophysics

Characterization

Algorithms

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 19Instrumentation

Page 20: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

Example – Measuring Formation Gas Saturation in a Problem Gas Reservoir

• Problems

– Complex completions (logging behind production tubing in largeComplex completions (logging behind production tubing in large boreholes)

– Mixed salinity: sigma is unreliable

– Variable shales

– We want:

• Gas saturation

• Identification of thin bed pay

• Raptor advantages?

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 20

Page 21: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

Advantage #1: InstrumentationRaptor Gas Sensitivity

Wet Response Line

Raptor 4-Detector ToolStandard 3-Detector Tool

Gas Response

Standard 3-Detector ToolRaptor 5-Detector Tool

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 21

Standard 2-Detector Tool

Page 22: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

Advantage #2: CharacterizationRaptor N-Vision High-Fidelity Gas Response Characterization

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 22

Page 23: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

Advantage # 3: CalibrationCalibration of Tool Sensitivity and Characterization

T100 N-Vision Calibration

Calibration of three tools

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 23

Page 24: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

Advantage #4: Algorithms and EquationsAnalytical Shale Calibration and Handling

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 24

Page 25: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

Upcoming Publication of Results

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 25

Page 26: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

The Road to High-Value Petrophysical Solutions

High-Value Answer Products

Distributed Analysis

Production Petrophysics

Characterization

Algorithms

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved. 26Instrumentation

Page 27: Raptor - Petroleum Club · Raptor A New High-Technology, High-Value Pulsed Neutron Measurement from WeatherfordPulsed Neutron Measurement from Weatherford Dr. Darryl Trcka

Raptor –Not just high-technology by Weatherford standards, high technology by world standards

D D l T k

© 2012 Weatherford. All rights reserved.© 2012 Weatherford. All rights reserved.

Dr. Darryl TrckaSenior Research Scientist Raptor Interpretive Product Manager