REA’S POND PUMP STATION REPLACEMENT Overcoming Obstacles to Remove Reservoir Contamination Threat Bruce Thibodeau, PE, Town of North Andover, MA; Tim Willett, Town of North Andover, MA; Ken Carlson, PE, Woodard & Curran; Jason Kreil, PE, Woodard & Curran

Upload: others

Post on 31-Jul-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

REA’S POND PUMP STATION REPLACEMENTOvercoming Obstacles to Remove Reservoir Contamination ThreatBruce Thibodeau, PE, Town of North Andover, MA; Tim Willett, Town of North Andover, MA; Ken Carlson, PE, Woodard & Curran; Jason Kreil, PE, Woodard & Curran

Page 2: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

2

Obstacles

§Land Ownership§Conservation Commission Approval of Land Swap§Town Meeting Eminent Domain Taking§Article 97 Legislative Action§Reduced Site Size§Stormwater Regulations§Local Watershed Protection District§Funding Limitations§The “Tree”

Page 3: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

3

Unique Features

§Segmental Pre-Cast Concrete Structures §Bypass Options§Surge and Transient Protection

Page 4: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

4

Town of North Andover

§30 miles Northwest of Boston§27,000 Residents§91 Miles of Sewers§22 Pump Stations§60% Sewered§Customer of GLSD

Page 5: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

5

Location Plan

Page 6: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

6

Rea’s Pond Pump Station Location

Culvert

French Farm Subdivision

Route 125

Great Pond RoadRoute 133

To Haverhill

Page 7: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

7

Rea’s Pond Pump Station Site

Source: Pictometry Bird’s Eye 2015 MDA Geospatial Services, Inc.; accessed from Bing® Images

Proposed Pump Station Location

Existing Pump Station

Rea’s Pond

Lake Cochichewick

§Located on Conservation Land and the Town’s Water Supply§Rea’s Pond and Lake

Cochichewick connected by Culvert

Culvert

Page 8: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

8

Tributary Sewered Area

Rea’s Pond

Culvert

Page 9: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

9

Existing Pump Station

§Constructed 1992 for French Farm Subdivision§Brooks School & Other Subdivisions Added Later§Pre-Cast Concrete Wet Pit/Dry Pit Type§500 gpm capacity§8” FM, Approx. 1 Mile in Length§No Record Plans

Page 10: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

10

Existing Pump Station Drawings

Page 11: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

11

Existing Pump Station

Page 12: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

12

A History of Overflows and Flooding

§Station Capacity Exceeded During Spring Storm Events within a Few Years§Overflow Wet Well Added pre-1999§Emergency Pump Connection Added §Portable Diesel Pumps and Vactors Needed for High Flows§10+ Years of Emergency Pumping§Several Overflow Close-Calls

Page 13: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

13

May 2006 Mother’s Day Storm

§17” of Rain in New England§Probable 100-Year Storm§Flood Waters Within 1 Foot of Structure Tops§Station Isolated from Access§Flood Waters at Elev. 118.0+/-§1999 Mitigation Raised Top of Structures to El. 119.0

Page 14: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

14

Congressional Earmark Funds – $100,000

§Initially to Address Shawsheen River Flooding Elevations§ACOE Completed Flood Elevation Survey Negating Funding Need§2010 Town Suggests Using Funding Towards Replacement of Rea’s Pond

Pump Station§Town receives OK to Use FEMA as Funding Agency with 25% Town Match§FEMA Approval of Hazard Mitigation Analysis Scope and Budget – 2011

Page 15: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

15

March 2012 Hazard Mitigation Analysis

§Established Design Flow §Condition Assessment§Evaluated Alternatives

ØGravity BypassØReplacement/Upgrade ØRelocate

§Recommendations:ØNew 950 gpm Station on Adjacent Conservation LandØHigher ElevationØReplace Sewers in Sutton Street

Page 16: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

16

Proposed Pump Station Site Plan and Sewer Plan

Page 17: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

17

New Pump Station Location

§ 13.5 Acre Mazurenko Farm Land Purchased by the Town in 1975 for Conservation Purposes

§ Land Placed under Article 97 Protection§ Land Swap with Conservation Commission Recommended

ØProposed Site for Existing SiteØExisting Site to be Restored after Station Demolition

§Required Legislative Approval

Page 18: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

18

EOEA Disposition Process - Article 97

§EOEA’s Disposition ProcessØConCom Vote that the Land is Surplus to its NeedsØTown Meeting Vote to Remove the Land from Protected StatusØFile an Environmental Notification Form with EOEA’s MEPA UnitØRequest Must Pass by a Two-Thirds Vote of the Massachusetts

Legislature and be Signed by the Governor

§“No Net Loss” – Land Swap Required to Offset Land Removed by Article 97 Action

Page 19: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

19

Existing and Proposed Easements

Existing Easement

New Pump Station Easement

Mazurenko Property / Conservation Land

French Farm Subdivision

Page 20: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

20

Easement Issues Uncovered Fall 2012

§Research Reveals Developer Owns Existing Easement§50-foot Right-of-Way was Retained by Property Owner in 1975§Town has No Rights to Existing Sewer and Pump Station Easement§Existing Pump Station Constructed Partially on Conservation Land

Page 21: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

21

Existing Pump Station Location

Existing Sewer Easement

Existing Pump Station

Page 22: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

22

Encroachment on Conservation Land

Existing Easement Line

Existing Pump Station Site

Conservation Land

Encroachment

Page 23: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

23

Site Issues Resolved

§Reduced New Pump Station Site per Conservation Commission Requirements and No Net Loss per Article 97§Conservation Commission Vote Approves Land Swap per Article 97§April 2013 – Town Meeting

ØTakes Sewer and Pump Station Easements and Facilities By Eminent DomainØApproves Filing Special Legislation for Article 97 Taking

§October 2014 – Article 97 Action Approved by Legislature

Page 24: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

24

Pump Station Design Changes

§Building Eliminated to Reduce Footprint to Fit Reduced Site§Segmental Pre-Cast Concrete Wet and Dry Well Proposed §Pump Station Changes Also Addressed Funding Limitations

Page 25: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

25

Project Timeline

2011 2012 2013 2014 2015 2016

Survey & Wetlands Delineation

Hazard Mitigation Analysis

ConCom Approves Easement

Town Meeting Approves Easement Takings

Sewer Replacement Design & Construction

Easements Granted by Legislature

Pump Station Design

Pump Station Construction

Page 26: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

26

Water Protection Considerations

§Station Designed Provide Additional Protection from Failure to Protect Water Quality of Adjacent Drinking Water SupplyØRaised Structures and Site Above the Estimated Flood PlainØIncreased Storage with Larger Wet WellØStandby Power for Complete Pump Station OperationØAdditional Alarms for High Water, Power Failure at Site and at Control PanelØAll Pumps on Timed Relays to Provide Backup in Event of CP FailureØBypass Piping for Various Bypass Pumping Configurations

Page 27: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

27

Water Quality Reminder

Page 28: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

28

Design

§Site LimitationsØSmall Site FootprintØWithin 100-foot Buffer of Pond and LakeØLocated in Zone A for Drinking Water Supply / Watershed Protection District

• Infiltration Prohibited• No Diesel Storage

§Utility LimitationsØUnreliable Grid Power at SiteØNatural Gas Not Available

Page 29: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

29

Design

§Pump Station to be Located West of Existing LocationØGround Surface 3 feet

above Existing LocationØPump Station Driveway

Accessible in 100-year Flood Condition

Resource Area: Inside 25-Foot Buffer:Inside 50-Foot Buffer:

Page 30: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

30

Design

§Stormwater ConsiderationØTown Wanted Paved Driveway for Convenience and MaintenanceØStormwater Runoff

• Insufficient Space for Treatment of Stormwater via Overland Flow• Insufficient Area for Retention/Detention• Zone A Infiltration Prohibition

ØProject Required to Meet Stormwater Standards by Conservation Commission

§Stormwater Infiltration within Zone A Approved by MADEP§Stormceptor and Subsurface Infiltration Most Effective Option

Page 31: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

31

Design

§Standby/Emergency PowerØPower

• No Natural Gas – Considered PropaneØPropane Required Significant Amount of Tank Storage Limited by

Overall Site FootprintØPropane Storage Triggered Additional Permitting

§Diesel Fuel Storage Prohibited in Watershed Protection DistrictØPlanning Board Issued Special Permit Allowing Diesel Generator with

Double Walled Tank and Active Leak SensorsØConservation Commission Agreed

Page 32: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

32

Design

§Package Precast Concrete §10’ x 20’ Rounded Corner Precast Structures § Approximately 23 Feet Below the Ground Surface§Geotechnical Report – Sand over Glacial Till§Shoring Specifications Required Sheet Pile Excavation§Dewatering Specifications Required a Well Point System

Page 33: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

33

Forcemain Design

§Connect to Existing Forcemain on Site§Performed Pump Tests to Determine Forcemain Characteristics

and System CurveØApproximate Hazen Williams C Value Range – 85 to 120ØDesign C Value – 95

Page 34: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

34

Pump Design

§Design FlowØExisting Flow/Normal Conditions – 450 gpm, 160 feet TDHØSeasonal High Flows/Buildout – 950 gpm, 257 feet TDH

§Concern about Water Hammer and Transients during High Flow OperationØSlow closing/Dampened Check ValvesØAir/Vacuum Release ValveØSurge Relief Valve

Page 35: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

35

Design

Page 36: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

36

Construction Timeline

FEB APR MAY JUL SEP OCT

Site Clearing / Erosion Control

Sheet Pile Installation by Vibratory Hammer / Waler

Dewatering System Installation

Excavation

Utility Connections

Pump Station Installation

Testing & Startup / AcceptancePower / Controls

Installation

JANNOV2015 2016

Site Piping / Connection to Existing Sewer Demolition

DEC

Final Site Work

Page 37: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

37

Construction

§Initial Site Work Began November 2015ØProject Used Force Labor from Town of North Andover to Reduce Cost

§Full Time RPR Began Mid-January 2016ØLayout and Excavation

Page 38: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

38

Construction

§Sand over Glacial Till§Sheet Pile and Dewatering Installation §Contractor Provided Internal Sump in Lieu of Wellpoints

ØAided by Drought and Low Pond and Lake Levels

Page 39: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

39

Construction

§Precast Structure InstallationØLimited Space – No StagingØNarrow, Busy Roadway with Traffic ControlØSchool Vacation Week Allowed for Staging

of Delivery Trucks in Nearby School Parking Lot

Page 40: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

40

Construction

Page 41: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

41

Construction

Page 42: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

42

Construction

Page 43: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

43

Construction

Page 44: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

44

Construction

Page 45: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

45

Construction

Page 46: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

46

Construction

Page 47: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

47

Construction

Page 48: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

48

Construction

Page 49: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

49

Construction

Page 50: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

50

Construction

Page 51: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

51

Construction

Page 52: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

52

Construction

Page 53: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

53

Construction

Page 54: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

54

Construction

Page 55: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

55

Construction

Page 56: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

56

Pump Station

§Stainless Clips/Brackets§Doweled Anti-Floatation

Slab Installation§New FM Connection

to ExistingØAllow Quick Transition

Between Stations for Testing

ØBypass Risers

Page 57: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

57

Site Work

Page 58: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

58

Construction

Page 59: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

59

Electric Utility Connection

§Multiple Delays on Site Power§Two Easements Required for

New Poles for PS Serviceand New Support Pole§10-week Delay, June –

August 2016§Transformer Installation and

Connection to Primary§At Last, Removal of “Tree”

Page 60: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

60

Construction

§Demolition – About 3 WeeksØRemoved All EquipmentØWet Well, Auxiliary Storage Wet Well

and Dry Pit Cut off 4 Feet Below Ground Surface, and Backfilled

ØGravity Sewer and Forcemain to Existing Station Removed, Capped and Secured

ØManhole Connections Plugged

Page 61: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

61

Stormwater Management System Installation

§Stormceptor§Stormwater Infiltration Basins

Page 62: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

62

Pump Testing / Acceptance

§Pumps Performed Above Design Criteria§Design C-Value = Conservative§Station Entered Operation October 2016

ØSmall Pump Operation, Large Pumps Exercised.ØPanel Heater

Page 63: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

63

Completed Station

Page 64: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

64

Completed Station

Page 65: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

65

Completed Station

Final Completion – Spring 2017§Outstanding Items

ØWarranty InspectionØSeeding and Final Cleanup of Parking Area

Page 66: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

66

Acknowledgements

§ Town of North AndoverØGlen Alt, Water Treatment Plant Superintendent, Pump Station O&MØDan Concessi, Assistant Operations Manager, Resident InspectorØJennifer Hughes, Conservation AdministratorØHeidi Gaffney, Conservation Field Inspector

§ Jack Troidl, Woodard & Curran, Project Manager§Kate Roosa, Woodard & Curran, Engineer§Maureen Herald/Steve Eriksen, Norse Environmental Services, Environmental Monitors§Dan Maurano, Bryant Associates, Resident Inspector§Mike Girard, Waterline Industries, Project Manager§ Jan Vastl, Waterline Industries, Superintendent

Page 67: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

67

Acknowledgements

A Special Acknowledgement to Bruce Thibodeau, Town of North Andover Director of Public Works, for Participation in this Presentation.

Bruce Retired on January 20, 2017.Best Wishes Bruce!

Page 68: REA’S POND PUMP STATION REPLACEMENT · 2017-10-17 · 26 Water Protection Considerations §Station Designed Provide Additional Protection from Failure to Protect Water Quality of

Questions?