reliance - obe · criteria, the reliance™-htc curtain wall system was developed by oldcastle...

2
To meet demands for more stringent thermal performance criteria, the Reliance -HTC curtain wall system was developed by Oldcastle BuildingEnvelope. ® Able to meet the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) climate zones 1-8, this thermal composite curtain wall system features outside glazing with captured and SSG vertical mullions, offering superior thermal performance through the use of polyamide struts. Reliance -HTC is offered in 7-1/4" and 10" depths for 1-3/4" glazing. Also available in 7-1/2" and 10-1/4" depths for 2" glazing. This system can accept our high performance AD-375 Thermal Door system as well as operable vents. Features Overall system dimensions: 2-1/2" x 7-1/4" and 10" for 1-3/4" glazing 2-1/2" x 7-1/2" and 10-1/4" for 2" glazing Front set, outside glazed configuration Captured and SSG vertical mullions Superior thermal separation provided through insulating strips on all vertical and horizontal members Enhanced acoustical properties Accommodates ZS-30 projected and casement vents Accommodates AD-375 Thermal Door system for superior thermal performance over the entire building envelope Factory painted Kynar 500 ® /Hylar 5000 ® finishes, meeting all provisions of AAMA 2605 Factory anodized finishing Iowa State University, Recreation Facility, Ames, IA Architect: RDg Planning & Design Reliance - HTC Curtain Wall— triple glaze thermal composite curtain wall system by Oldcastle BuildingEnvelope ® Reliance -HTC curtain wall system

Upload: others

Post on 25-Apr-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

To meet demands for more stringent thermal performance

criteria, the Reliance™-HTC curtain wall system was developed

by Oldcastle BuildingEnvelope.® Able to meet the American Society

of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)

climate zones 1-8, this thermal composite curtain wall system features

outside glazing with captured and SSG vertical mullions, offering

superior thermal performance through the use of polyamide struts.

Reliance™-HTC is offered in 7-1/4" and 10" depths for 1-3/4" glazing.

Also available in 7-1/2" and 10-1/4" depths for 2" glazing. This

system can accept our high performance AD-375 Thermal Door

system as well as operable vents.

Features

■ Overall system dimensions: 2-1/2" x 7-1/4" and 10" for 1-3/4" glazing 2-1/2" x 7-1/2" and 10-1/4" for 2" glazing

■ Front set, outside glazed configuration

■ Captured and SSG vertical mullions

■ Superior thermal separation provided through insulating strips on all vertical and horizontal members

■ Enhanced acoustical properties

■ Accommodates ZS-30 projected and casement vents

■ Accommodates AD-375 Thermal Door system for superior thermal performance over the entire building envelope

■ Factory painted Kynar 500®/Hylar 5000® finishes, meeting all provisions of AAMA 2605

■ Factory anodized finishing

Iowa State University, Recreation Facility, Ames, IAArchitect: RDg Planning & Design

Reliance™- HTC Curtain Wall— triple glaze thermal composite curtain wall system by Oldcastle BuildingEnvelope®

Reliance

™-HTC

curtain wall system

2425 Olympic Boulevard, Suite 525-East n Santa Monica, CA 904041-866-OLDCASTLE (653-2278) n oldcastlebe.com

Reliance

™-HTC

curtain wall system

Performance

Details

Standard Details Available in Multiple Depths

Entrance Details with AD-375

■ Air Infiltration: <.06 CFM/SQ FT (6.24 PSF) per ASTM E283

■ Static Water: 15 PSF per ASTM E331

■ Dynamic Water: 15 PSF per AAMA 501.1

■ Deflection Load: 40 PSF per ASTM E330

■ Structural Load: 60 PSF per ASTM E330

■ Seismic: Three levels of deflection per AAMA 501.4

■ STC: 33 (3 x 1/4", 2 x 1/2" airspace) 39 (3 x 1/4" laminated, 2 x 1/2" airspace)

■ OITC: 28 (3 x 1/4", 2 x 1/2" airspace) 30 (3 x 1/4" laminated, 2 x 1/2" airspace)

■ Thermal Performance per AAMA 1503 for clear 1-3/4" insulating glass: U-factor = 0.37 CRF = 81 for Low-E 1-3/4" insulating glass: U-factor = 0.20 CRF = 84

■ NFRC Certified

■ Thermal Performance Characteristics per AAMA 507