relief well injection spool - … · valve based design • erosion resistant ... api 17h...

2
Key Facts Designed to API Specifications I3P design verified Rated to 10,000 FSW &15,000 psi Valve based design Erosion resistant and high flow capacity Manufactured by Trendsetter Engineering Air Freightable and Rapid Deployable Configurable with or without a RAM KEY FEATURES RELIEF WELL INJECTION SPOOL TECHNICAL INFORMATION SHEET RELIEF WELL INJECTION SPOOL 183/4 15ksi: Wellhead Connector - Cameron HCH4 183/4 15ksi: Single Pipe Shear/ Blind RAM (Optional) ROV Panels 4” Horizontal Connector each side, API 17H 41/16” Slab Gate Valves x2 FSC each side 183/4 15ksi: Mandrel H4 VX/VT RELIEF WELL INJECTION SPOOL Device developed to ensure single relief well contingency for offshore blowouts Gives operators permission to drill wells in challenging/sensitive areas Offers cost savings on well and field development projects Mounted on top of the Relief Well Wellhead Sits between the wellhead and the BOP and has the same bore as the BOP (18 ¾”) Includes two valve inlets for high rate pumping Permits significantly more flow capacity Requires no modifications to existing rig systems Does not interfere with primary well control equipment Includes additional well isolation barrier (Optional Lower Pipe Shear RAM) Operated from surface (RIG) and ROV 4x 4" 15K GATE VALVES ONBOARD ACCUMULATION 2x 4" 10K LARGE BORE STABS 4x 4" 15K GATE VALVES ONBOARD ACCUMULATION 2x 4" 10K LARGE BORE STABS

Upload: phungduong

Post on 03-Apr-2018

214 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: RELIEF WELL INJECTION SPOOL - … · Valve based design • Erosion resistant ... API 17H 4˙/ˆˇ” Slab Gate Valves x2 FSC each side 18˛/˝ 15ksi: Mandrel ... Material Trim per

Key Facts•

Designed to API Speci�cations•• I3P design veri�ed •

Rated to 10,000 FSW &15,000 psi

• Valve based design

• Erosion resistant and high �ow capacity

• Manufactured by Trendsetter Engineering•

Air Freightable and Rapid Deployable Con�gurable with or without a RAM

KEY FEATURESRELIEF WELL INJECTION SPOOL

TECHNICAL INFORMATION SHEET

RELIEF WELL INJECTION SPOOL

183/4 15ksi: WellheadConnector - Cameron HCH4

183/4 15ksi:Single Pipe Shear/ Blind RAM

(Optional)

ROV Panels

4” Horizontal Connectoreach side, API 17H

41/16” Slab Gate Valvesx2 FSC each side

183/4 15ksi: MandrelH4 VX/VT

R E L I E F W E L L I N J E C T I O N S P O O L

Device developed to ensure single relief well contingency for o�shore blowoutsGives operators permission to drill wells in challenging/sensitive areasO�ers cost savings on well and �eld development projectsMounted on top of the Relief Well WellheadSits between the wellhead and the BOP and has the same bore as the BOP (18 ¾”) Includes two valve inlets for high rate pumping Permits signi�cantly more �ow capacityRequires no modi�cations to existing rig systemsDoes not interfere with primary well control equipmentIncludes additional well isolation barrier (Optional Lower Pipe Shear RAM)Operated from surface (RIG) and ROV

4x 4" 15K GATE VALVES

ONBOARDACCUMULATION

2x 4" 10KLARGE BORE STABS

4x 4" 15K GATE VALVES

ONBOARDACCUMULATION

2x 4" 10KLARGE BORE STABS

Page 2: RELIEF WELL INJECTION SPOOL - … · Valve based design • Erosion resistant ... API 17H 4˙/ˆˇ” Slab Gate Valves x2 FSC each side 18˛/˝ 15ksi: Mandrel ... Material Trim per

CROSS SECTION OF FLOW PATH SPECIFICATION

Relief Well Injection Spool

Design Life

Design Life (pumping)

Exposure Time

(seal exposure to corrosive kill mud )

Water Depth rating

Design Pressure – System

Design Pressure –

Wellhead connector, BOP,

Chemical Injection lines, Inlet Diverter,

Bore Isolation Valves, Upper Mandrel

Design Pressure –

4” Horizontal Connectors

Rated Working Pressure –

Wellhead Connector Function Lines

Rated Working Pressure –

Isolation Valve Hydraulic Functions

Control Fluid Cleanliness Level

Rated Working Pressure –

BOP Function Lines

Operating Temperature Rating

(Structures)

Operating Temperature Rating

(Flowline Equipment)

Storage Temperature

(Equipment and Structures)

System Hydraulic Fluid

Product Speci�cation Level –

Flowline Valves & Vertical Connectors

Material Trim per API 6A

NACE MR0175 Compliant

1/20 yrs 1

6 hours 2

24 hours 3

10,000 ft

10,000 psig

15,000 psig

10,000 psig (minimum)

3,000 psig

3,000 psig

SAE AS-4059 Class 10B-F

5,000 psig

-20°C to 60°C

[-4°F to 140°F]

-4°C to 60°C

[25°F to 140°F]

-20 °C to 60°C

[-4 °F to 140°F]

Pelagic 100

PSL 3

DD minimum

Yes

(inside of isolation barriers)

WEIGHT (AIR): 135,000 LBS APPROX.62,250 KG APPROX. W/ RAM

Well kill �ow modelling by: Manufactured by:

Add Energy Group ASWell Control & Blowout Support

NORWAYVisiting address: Strandveien 33, N-1366 LysakerP.O. Box 26,N-1324 Lysaker, Norwaytel +47 66 98 32 90

USA19500 State Highway 249Suite 380Houston, TX 77070Tel +1 832 604 7326

www.addenergygroup.com

1) The RWIS is designed for a minimum of 20 years shelf life. Cathodic protection is designed for a minimum of 1 year installed subsea.2) The pumping design life sets the parameters for allowable erosion rates during the pumping life of the RWIS.3) The exposure time is the minimum design life of any elastomeric seals exposed to kill mud.

WEIGHT (AIR): 70,000 LBS APPROX. 31,750 KG APPROX. W/O RAM

Trendsetter EngineeringLeader in Contemporary Subsea Solutions

Visiting address: 10430 Rodgers Road Houston, Texas 77070

USA

tel +1 281-465-8858